BP5224-33
DC/DC converter
3.3V/300mA output
Dimensions (mm)
Absolute Maximum Ratings
Unit
24
−20 to +80
−25 to +105
105
300
V
°C
°C
°C
mA
9.7Max.
17.8Max.
BP5224-33
Marking side
Limits
VIN
Topr
Tstg
Tcmax
Iopeak
18.1Max.
Symbol
4.0±1.0
Parameter
Input voltage
Operating temperature
Storage temperature
Maximum surface temperature
Maximum output current
1
2
4
5
6
0.5±0.1
3.3Max.
0.25±0.05
1.3±0.2
P=2.54±0.2
3.65Max.
6.05Max.
2.54x5=12.7(TYP.)
Electrical Characteristics
Typ.
Max.
18.0
3.46
300
0.10
0.15
0.15
−
16.0
3.3
−
0.03
0.07
0.06
71
DC
Vin=7 to 18V
Io=0 to 300mA
BP5224-33
1
2
4
5
6
300
250
200
150
100
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Function
Input terminal Vi
Input terminal Vi
Skip
GND
GND
Output terminal Vo
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
Conversion Efficiency
(Ta=25°C, Vin=16V)
50
100 150 200 250 300
Output Current Io(A)
Load Regulation
VIN
C2
Vo
Be sure to evaluate it under the cindition that it is mounted by your product.
Especially, Confirm whether output current never exceeds a maximum standard
with current probe.
Outside part
F1: FUSE
Use a fuse for safety.
C1: Input capacitor
Rated voltage : More than 50V
Capacity : more than 100µF, low impedance type
Rated ripple current : More than 0.2Arms
C2: Output capacitor
Rated voltage : More than 10V
Capacity : 220 to 680µF, low impedance type
Rated ripple current : More than 0.2Arms
Evaluate it with the actual opportunity because
it influences an output ripple voltage.
Output Voltage Vo(V)
F1
C1
50
∗2
Application circuit
Pin No.
1
2
3
4
5
6
Derating Curve
350
∗1
∗1 Maximum output current varies depending on ambient temperature : please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
BP5224-33
Derating curve
Conditions
Unit
V
V
mA
V
V
Vp-p
%
Conversion Efficiency η (%)
Min.
7.0
3.14
−
−
−
−
68
Output Current Io(A)
Symbol
Parameter
Input voltage
Vin
Output voltage
Vo
Output current
Io
Line regulation
Vr
Load regulation
VI
Output ripple voltage
Vp
η
Power conversion efficiency
4.0
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
2.0
0
Load Regulation
(Ta=25°C)
VIN=7V
VIN=16V
50
100 150 200 250
Output Current Io(A)
300
Appendix
Notes
No technical content pages of this document may be reproduced in any form or transmitted by any
means without prior permission of ROHM CO.,LTD.
The contents described herein are subject to change without notice. The specifications for the
product described in this document are for reference only. Upon actual use, therefore, please request
that specifications to be separately delivered.
Application circuit diagrams and circuit constants contained herein are shown as examples of standard
use and operation. Please pay careful attention to the peripheral conditions when designing circuits
and deciding upon circuit constants in the set.
Any data, including, but not limited to application circuit diagrams information, described herein
are intended only as illustrations of such devices and not as the specifications for such devices. ROHM
CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any
third party's intellectual property rights or other proprietary rights, and further, assumes no liability of
whatsoever nature in the event of any such infringement, or arising from or connected with or related
to the use of such devices.
Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or
otherwise dispose of the same, no express or implied right or license to practice or commercially
exploit any intellectual property rights or other proprietary rights owned or controlled by
ROHM CO., LTD. is granted to any such buyer.
Products listed in this document are no antiradiation design.
The products listed in this document are designed to be used with ordinary electronic equipment or devices
(such as audio visual equipment, office-automation equipment, communications devices, electrical
appliances and electronic toys).
Should you intend to use these products with equipment or devices which require an extremely high level
of reliability and the malfunction of which would directly endanger human life (such as medical
instruments, transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers
and other safety devices), please be sure to consult with our sales representative in advance.
It is our top priority to supply products with the utmost quality and reliability. However, there is always a chance
of failure due to unexpected factors. Therefore, please take into account the derating characteristics and allow
for sufficient safety features, such as extra margin, anti-flammability, and fail-safe measures when designing in
order to prevent possible accidents that may result in bodily harm or fire caused by component failure. ROHM
cannot be held responsible for any damages arising from the use of the products under conditions out of the
range of the specifications or due to non-compliance with the NOTES specified in this catalog.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact your nearest sales office.
ROHM Customer Support System
www.rohm.com
Copyright © 2007 ROHM CO.,LTD.
THE AMERICAS / EUPOPE / ASIA / JAPAN
Contact us : webmaster@ rohm.co. jp
21, Saiin Mizosaki-cho, Ukyo-ku, Kyoto 615-8585, Japan
TEL : +81-75-311-2121
FAX : +81-75-315-0172
Appendix1-Rev2.0
Similar pages