LKC05W SERIES TINY-RIPPLE DC-DC CONVERTER 4:1 ULTRA WIDE INPUT RANGE UP TO 5 WATTS FEATURES APPLICATIONS • ULTRA LOW RIPPLE AND NOISE • STANDARD 1.25 X 0.80 X 0.40 INCH • BUILT-IN EN55022 CLASS B FILTER • SIX SIDE SHIEDING • 1600VDC INPUT TO OUTPUT ISOLATION • SAFETY MEETS UL60950-1, EN60950-1 , & IEC60950-1 • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL UVP OCP • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • MEASUREMENT EQUIPMENT • SEMICONDUCTOR EQUIPMENT SCP OVP LOW STANDBY POWER TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted Input Range Output Voltage Output Current @Full Load LKC05-24S3P3W LKC05-24S05W LKC05-24S12W LKC05-24S15W LKC05-24S24W LKC05-24D05W LKC05-24D12W LKC05-24D15W LKC05-24D24W VDC 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 LKC05-24DS05W 9 ~ 36 LKC05-24DS12W 9 ~ 36 LKC05-24DS15W 9 ~ 36 LKC05-24DS24W 9 ~ 36 VDC 3.3 5 12 15 24 ±5 ±12 ±15 ±24 Vout1: 5 Vout2: 5 Vout1: 12 Vout2: 12 Vout1: 15 Vout2: 15 Vout1: 24 Vout2: 24 3.3 5 12 15 24 ±5 ±12 ±15 ±24 Vout1: 5 Vout2: 5 Vout1: 12 Vout2: 12 Vout1: 15 Vout2: 15 Vout1: 24 Vout2: 24 mA 1515 1000 416 333 208 ±500 ±208 ±166 ±104 500 500 208 208 166 166 104 104 1515 1000 416 333 208 ±500 ±208 ±166 ±104 500 500 208 208 166 166 104 104 Model Number LKC05-48S3P3W LKC05-48S05W LKC05-48S12W LKC05-48S15W LKC05-48S24W LKC05-48D05W LKC05-48D12W LKC05-48D15W LKC05-48D24W 18~ 75 18~ 75 18~ 75 18~ 75 18~ 75 18~ 75 18~ 75 18~ 75 18~ 75 LKC05-48DS05W 18~ 75 LKC05-48DS12W 18~ 75 LKC05-48DS15W 18~ 75 LKC05-48DS24W 18~ 75 1 Input Current @ No Load www.PDUKE.com mA 6 6 9 10 10 6 9 10 10 Output Ripple & Noise mV Efficiency % 81 83 88 88 89 84 85 86 87 6 84 9 85 10 86 10 4 4 4 4 6 6 4 5 6 86 10 80 83 86 87 88 83 85 86 87 6 83 4 85 5 86 6 86 Maximum Capacitor Load µF 2200 1000 220 150 100 ± 680 ± 150 ± 150 ± 100 680 680 150 150 150 150 100 100 2200 1000 220 150 100 ± 680 ± 150 ± 150 ± 100 680 680 150 150 150 150 100 100 2016/03/29 LKC05W PART NUMBER STRUCTURE LKC05 Series Name 24 Input Voltage (VDC) 24:9~36 48:18~75 S 05 W Output Quantity Output Voltage (VDC) 3P3:3.3 05:5 12:12 15:15 24:24 05:±5 12:±12 15:±15 24:±24 05:5/5 12:12/12 15:15/15 24:24/24 Input Range Assembly Option 4:1 :With Pin3 CS:Without Pin3 S:Single D:Dual DS:Dual with output isolation INPUT SPECIFICATIONS Parameter 24Vin(nom) 48Vin(nom) 24Vin(nom) 48Vin(nom) 24Vin(nom) 48Vin(nom) Power up Remote ON/OFF 24Vin(nom) 48Vin(nom) Start-up voltage Shutdown voltage Start up time Constant resistive load Input surge voltage 1 second, max. Input filter Remote ON/OFF Referred to –Vin pin OUTPUT SPECIFICATIONS Parameter Load regulation Conditions 36 75 9 18 -0.5 Low Line to High Line at Full Load No Load to Full Load Asymmetrical load 25%/100% FL Typ. -3.0 +3.0 -0.5 -6.0 -0.5 -4.0 -10 -10 -10 +0.5 +6.0 +0.5 +4.0 +20 +10 +10 15 10 +0.02 -0.02 www.PDUKE.com mA mA % % □□D□□W 50% load step change % of Vout(nom) % of Iout rated; Hiccup mode VDC Unit +0.2 +0.2 +0.2 +1.0 +0.5 +1.0 +0.5 +1.0 10 5 ms +1.0 10 Measured by 20MHz bandwidth Measured by 20MHz bandwidth, with additional 10µF Capacitor VDC Max. -0.2 -0.2 -0.2 -1.0 -0.5 -1.0 -0.5 -1.0 □□S□□W □□D□□W □□DS□□W VDC VDC □□DS□□W □□S□□W □□D□□W □□DS□□W Vout 2(Main) Vout 1(Aux) □□S□□W □□D□□W □□DS□□W Vout 2(Main) Vout 1(Aux) Vout 2(Main) Vout 1(Aux) Vout 2(Main) Vout 1(Aux) Unit 75 75 50 100 Common Chock Open or 3 ~ 12VDC Short or 0 ~ 1.2VDC 1 3 -1.0 Voltage adjustability 2 Max. 24 48 Min. Others Temperature coefficient Transient response recovery time Over voltage protection Over load protection Short circuit protection Typ. 9 18 8.5 16 50 50 DC-DC ON DC-DC OFF Input current of Ctrl pin Remote off input current □□DS05W Ripple and noise Min. Positive logic 10% Full Load to Full Load Cross regulation CS Conditions Operating input voltage range Voltage accuracy Minimum load Line regulation - % % % % mVp-p %/℃ 250 µs 135 % 170 % Continuous, automatics recovery 2015/8/28 LKC05W GENERAL SPECIFICATIONS Parameter Isolation voltage Isolation resistance Isolation capacitance Switching frequency Safety meets Case material Base material Potting material Weight MTBF Conditions 1 minute 500VDC Max. Unit VDC 300 MIL-HDBK-217F, Full load Conditions Operating ambient temperature Min. Without derating With derating Typ. -40 +85 -55 Natural convection EMC SPECIFICATIONS Parameter EMI (1) ESD Radiated immunity Fast transient (2) Surge (2) Conducted immunity Power frequency magnetic field Typ. 1600 1600 500 1 GΩ pF kHz UL60950-1 EN60950-1 IEC60950-1 Copper FR4 PCB Epoxy (UL94 V-0) 14.8g(0.52oz) 4.446 x 106 hrs 1200 ENVIRONMENTAL SPECIFICATIONS Parameter Maximum case temperature Storage temperature range Thermal impedance Thermal shock Vibration Relative humidity Min. Input to Output Input (Output) to Case Vout 1 to Vout 2; □□DS□□W only 20 Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 Max. Unit +85 +100 +105 +125 ℃ ℃ ℃ ℃/W MIL-STD-810F MIL-STD-810F 5% to 95% RH Level Air ± 8kV and Contact ± 6kV 20 V/m ± 2kV ± 2kV 10 Vr.m.s 100A/m continuous; 1000A/m 1 second Class A, Class B Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Note: 1. 2. The standard modules meet EN55022 Class A without external components. The standard modules meet EN55022 Class B as following information: LKC05-24W : Do not need any external components. LKC05-48W : Connect two 4.7µF/100V MLCCs in parallel to input pins. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The LKC05-24W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ70A, 70V, 3000Watt peak pulse power) to connect in parallel. The LKC05-48W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ120A, 120V, 3000Watt peak pulse power) to connect in parallel. CAUTION: This power module is not internally fused. An input line fuse must always be used. CHARACTERISTIC CURVE LKC05-48S05W Derating Curve 3 LKC05-48S05W Efficiency vs. Input Voltage www.PDUKE.com LKC05-48S05W Efficiency vs. Output Load 2016/03/29 LKC05W MECHANICAL DRAWING PIN CONNECTION LKC05-□□S□□W PIN DEFINE 1 +Vin 2 +Vin 3 Case PIN 24 23 22 DEFINE -Vin -Vin Ctrl 15 14 13 +Vout -Vout Trim PIN 24 23 22 DEFINE -Vin -Vin Ctrl Com +Vout 1 Case 15 14 13 Com -Vout 2 Trim LKC05-□□DS□□W PIN DEFINE 1 +Vin 2 +Vin 3 Case PIN 24 23 22 DEFINE -Vin -Vin Ctrl 15 14 13 +Vout 2 (Main) -Vout 2 Trim 10 11 12 No pin No pin Case LKC05-□□D□□W PIN DEFINE 1 +Vin 2 +Vin 3 Case 10 11 12 1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1) 10 11 12 (Aux) -Vout 1 (Aux) +Vout 1 Case (Main) EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. LKC05-□□S□□W; LKC05-□□DS□□W LKC05-□□D□□W 4 www.PDUKE.com 2016/03/29