Sumida LC-14 General power transformer Datasheet

General Power Transformer <Pin Type: LC Series>
Type: LC-14
◆ Product Description
・¢14.5mm Max.(L×W), 6.6mm Max. Height
・In addition to the typical versions of parameters shown here,
custom designs are available to meet your exact requirements
◆ Feature
・Magnetically shielded construction.
・Max. Operating frequency 300kHz,Max. Operating Power 3.8W(300kHz), 1.3W(100kHz).
・Ideally used in Portable equipment, Drive for fluorescent display tube.
・RoHS Compliance
+0.1
φ 0.5-0.05
◆ Dimensions (mm)
36
。
φ8.0±0.25
MAX.6.6
3.5±0.5
◆ Schematics (Bottom)
S
④
⑤
⑥
③
⑦ S
②
S
φ14.0±0.5
⑧
①
⑨
“ S” is winding start
◆ Specification
Sample No.
0376 - T056
Inductance (7-9)
1kHz/1V
1.1mH ± 30%
within
D.C.R.
(1-3)
0.88Ω Max.
Please refer to the sales offices on our website for a representative near you
www.sumida.com
1/1