Omron G2R-1A4 1general purpose power relays of single-pole10 a and double-pole 5 a. Datasheet

G2R
PCB Power Relay
The Best Seller G2R
• 1General purpose power Relays of single-pole10 A and double-pole 5 A.
• Safety-oriented design with dielectric strength of 5,000 V between coil
and contacts, and surge resistance of 10,000 V.
• AC and DC types are both available for operational coils.
RoHS Compliant
■Model Number Legend
G2R- @ - @ @ @@ -@@
— ———— ——
1
2 3 4 5
6 7
1. Relay Function
None: Single-side stable
K : Double-winding latching
4. Contact Type
None: Single
Z : Bifurcated contact
2. Number of poles
1: 1-pole
2: 2-pole
5. Enclosure rating
None: Flux protection
(T-type is an enclosed
relay)
4 : Fully sealed
3. Contact Form
None: NO/NC
A : NO
6. Terminal Shape
None: PCB terminals
T : Quick-connect
(upper bracket mounting
#187)
7. Classification
None: Standard
E : High-capacity
H : High-sensitivity
U : For ultrasonically
cleanable
Z : Full-wave rectifier
G
2
R
■Model Configuration
Number of poles
Terminal
Shape
Classification
Enclosure
rating
Flux protection
Standard
Fully sealed
Bifurcated
PCB terminals contact
Flux protection
Fully sealed
Contact
form
AC
DC
AC
DC
DC
AC
1-pole
SPST-NO (1a)
2-pole
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
G2R-1A
G2R-1
G2R-2A
G2R-2
G2R-1A4
G2R-14
G2R-2A4
G2R-24
G2R-1AZ
G2R-1Z
−
−
G2R-1AZ4
G2R-1Z4
−
−
G2R-1A-E
G2R-1-E
−
−
High-capacity
Flux protection
High-sensitivity
Flux protection
DC
G2R-1A-H
G2R-1-H
G2R-2A-H
G2R-2-H
Double-winding
latching
Flux protection
DC
G2RK-1A
G2RK-1
G2RK-2A
G2RK-2
G2R-1A-T
G2R-1-T
−
−
Quick-connect Standard
Unsealed
DC
AC
DC
Minimum
packing
unit
50
pcs/tray
100
pcs/tray
Note 1. Full-wave rectifier and supersonic cleaner compatible models are also available. Refer to page 3.
2. Sockets for PCB terminal models are not provided.
Use the plug-in terminal Relay instead of socket if necessary.
1
G2R
PCB Power Relay
■Ordering Information
● PCB Terminal Models
Number of poles
Classification
Enclosure rating
Contact form
1-pole
Model
Rated coil voltage
2-pole
Model
12, 24, 100/(110) VAC
NO
G2R-1A
200/(220) VAC
5, 6, 12, 24, 48 VDC
G2R-2A
100 VDC
Flux protection
NO/NC
G2R-1
General-purpose
NO
G2R-1A4
Fully sealed
NO/NC
G2R-14
High-sensitivity
Flux protection
Double-winding
latching
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
12, 24, 100/(110) VAC
200/(220) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
G2R-2
5, 6, 12, 24, 48 VDC
100 VDC
100 VDC
12, 24, 100/(110) VAC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
G2R-2A4
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
100 VDC
12, 24, 100/(110) VAC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
G2R-24
100 VDC
G
2
R
Rated coil voltage
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
NO
G2R-1A-H
5, 6, 12, 24, 48 VDC
G2R-2A-H
5, 6, 12, 24, 48 VDC
NO/NC
G2R-1-H
5, 6, 12, 24, 48 VDC
G2R-2-H
5, 6, 12, 24, 48 VDC
NO
G2RK-1A
5, 6, 12, 24 VDC
G2RK-2A
5, 12, 24 VDC
NO/NC
G2RK-1
5, 6, 12, 24 VDC
G2RK-2
5, 6, 12, 24 VDC
NO
G2R-1AZ
NO/NC
G2R-1Z
NO
G2R-1AZ4
NO/NC
G2R-1Z4
Flux protection
Bifurcated
contact
Fully sealed
12, 24, 48 VDC
100 VDC
5, 6, 12, 24, 48 VDC
−
100 VDC
5, 12, 24, 48 VDC
100 VDC
5, 12, 24, 48 VDC
−
100 VDC
12, 24, 100/(110) VAC
NO
High-capacity
G2R-1A-E
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Flux protection
12, 24, 100/(110) VAC
NO/NC
G2R-1-E
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A 12 VAC
Rated coil voltage
2
−
−
G2R
PCB Power Relay
● Quick-connect Terminal (#187)
Number of poles
Classification
Enclosure rating
Contact form
1-pole
Model
Rated coil voltage
12, 24, 100/(110) VAC
NO
General-purpose
G2R-1A-T
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Unsealed
12, 24, 100/(110) VAC
NO/NC
G2R-1-T
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
● Full-wave Rectifier
Number of poles
Classification
Enclosure rating
Contact form
NO
1-pole
Model
G2R-1A-Z
Flux protection
NO/NC
G2R-1-Z
General-purpose
NO
G2R-1A4-Z
Fully sealed
High-capacity
NO/NC
G2R-14-Z
NO
G2R-1A-EZ
NO/NC
G2R-1-EZ
Flux protection
Rated coil voltage
5, 12, 24 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
5, 12, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
2-pole
Model
G2R-2A-Z
G2R-2-Z
G2R-2A4-Z
G2R-24-Z
Rated coil voltage
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 48 VDC
100 VDC
24, 48 VDC
100 VDC
5, 12, 24 VDC
G
2
R
100 VDC
5, 12, 24 VDC
100 VDC
−
12, 24, 48 VDC
100 VDC
● For Ultrasonically Cleanable
Number of poles
Classification
Enclosure rating
Contact form
1-pole
Model
Rated coil voltage
2-pole
Model
12, 24, 100/(110) VAC
NO
General-purpose
G2R-1A4-U
Fully sealed
NO/NC
G2R-14-U
200/(220) VAC
Rated coil voltage
100/(110) VAC
−
G2R-2A4-U
5, 6, 12, 24, 48 VDC
5, 12, 24 VDC
12, 100/(110) VAC
200/(220) VAC
12, 24, 100/(110) VAC
200/(220) VAC
5, 12, 24, 48 VDC
100 VDC
G2R-24-U
5, 12, 24, 48 VDC
100 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A-T 12 VAC
Rated coil voltage
3
G2R
PCB Power Relay
■Ratings
● Coil
Item
Classification
•
•
•
•
Rated voltage
General-purpose
Quick-connect
Fully sealed
High-capacity
Rated current (mA)
50 Hz
12 VAC
93
75
24 VAC
46.5
37.5
100/(110) VAC
11
200/(220) VAC
5 VDC
•
•
•
•
•
General-purpose
High-capacity
Bifurcated contact
Quick-connect
Fully sealed
• High-sensitivity
5.5
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V)
Power
consumption
(VA, W)
% of rated voltage
65
260
9/(10.6)
4,600
4.5/(5.3)
20,200
106
80% max.
30% min.
140%
(at 23°C)
Approx. 0.9
(60 Hz)
70% max.
15% min.
170%
(at 23°C)
Approx. 0.53
70% max.
15% min.
170%
(at 23°C)
Approx. 0.36
47
6 VDC
88.2
12 VDC
43.6
275
24 VDC
21.8
1,100
68
48 VDC
11.5
4,170
100 VDC
5.3
18,860
5 VDC
71.4
6 VDC
60
100
12 VDC
30
400
24 VDC
15
1,600
48 VDC
G
2
R
60 Hz
Coil resistance
(Ω)
70
7.5
6,400
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of+15%/-20% (AC rated current) or ±10% (DC coil resistance).
2. AC coil resistances shown above are only reference values.
3. The operating characteristics are measured at a coil temperature of 23°C.
4. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
● Coil: Double-winding Latching Relays
Item
Rated voltage
Set Coil
Rated current
(mA)
Must set
voltage (V)
Reset coil
Coil resistance
(Ω)
Rated current
(mA)
Coil resistance
(Ω)
42
5 VDC
167
30
119
6 VDC
138
43.5
100
60
12 VDC
70.6
170
50
240
24 VDC
34.6
694
25
960
Must reset Max. voltage
voltage (V)
(V)
% of rated voltage
70% max.
70% max.
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
4
140%
(at 23°C)
Power consumption
Set Coil
(mW)
Reset coil
(mW)
Approx.
850
Approx.
600
G2R
PCB Power Relay
● Contacts
Classification
Number of poles
Load
Item
General-purpose
Quick-connect Terminal (1single-pole type)
1-pole
High-capacity
Bifurcated contact
1-pole
2-pole
2-pole
High-sensitivity
1-pole
2-pole
Inductive
Inductive
Inductive
Inductive
Inductive
Inductive
load
load
load
load
load
load
Resistive
Resistive
Resistive
Resistive
Resistive
Resistive
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
load
load
load
load
load
load
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
Contact type
Single
Single
Bifurcated
Contact material
Single
Ag-alloy (Cd free)
10 A at
250 VAC
10 A at 30
VDC
Rated load
Rated carry current
7.5 A at
250 VAC
5 A at 30
VDC
5 A at 250
VAC
5 A at 30
VDC
10 A
Max. switching voltage
2 A at 250
VAC
3 A at 30
VDC
16 A at
250 VAC
16 A at 30
VDC
5A
8 A at 250
VAC
8 A at 30
VDC
5 A at 250
VAC
5 A at 30
VDC
16 A
380 VAC, 125 VDC
2 A at 250
VAC
3 A at 30
VDC
5A
5 A at 250
VAC
5 A at 30
VDC
2 A at 250
VAC
3 A at 30
VDC
3 A at 250
VAC
3 A at 30
VDC
5A
380 VAC, 125 VDC
1 A at 250
VAC
1.5 A at
30 VDC
3A
380 VAC, 125 VDC
Max. switching current
10 A
5A
16 A
5A
5A
3A
Failure rate (P level)
(reference value) *
100 mA at 5 VDC
10 mA at 5 VDC
100 mA at 5 VDC
1 mA at 5 VDC
100 mA at 5 VDC
10 mA at 5 VDC
* This value was measured at a switching frequency of 120 operations/min.
● Contacts: Fully Sealed Models
Classification
General-purpose (Single contact)
Number of poles
Load
Item
Bifurcated contact
1-pole
Resistive load
(cosφ = 1)
Contact type
2-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
Single
1-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
Single
Contact material
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Bifurcated
G
2
R
Ag-alloy (Cd free)
8 A at 250 VAC
8 A at 30 VDC
Rated load
Rated carry current
6 A at 250 VAC
4 A at 30 VDC
4 A at 250 VAC
4 A at 30 VDC
1.5 A at 250 VAC
2.5 A at 30 VDC
5 A at 250 VAC
5 A at 30 VDC
2 A at 250 VAC
3 A at 30 VDC
8A
4A
5A
Max. switching voltage
380 VAC, 125 VDC
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
8A
4A
5A
100 mA at 5 VDC
10 mA at 5 VDC
1 mA at 5 VDC
Failure rate (P level)
(reference value) *
* This value was measured at a switching frequency of 120 operations/min.
● Contacts: Latching Models
Number of poles
Item
Load
1-pole
Resistive load
(cosφ = 1)
Contact type
2-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single
Rated carry current
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single
Contact material
Rated load
Resistive load
(cosφ = 1)
Ag-alloy (Cd free)
5 A at 250 VAC
5 A at 30 VDC
3.5 A at 250 VAC
2.5 A at 30 VDC
3 A at 250 VAC
3 A at 30 VDC
1.5 A at 250 VAC
2 A at 30 VDC
5A
3A
Max. switching voltage
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
5A
3A
Failure rate (P level)
(reference value) *
100 mA at 5 VDC
10 mA at 5 VDC
* This value was measured at a switching frequency of 120 operations/min.
5
G2R
PCB Power Relay
■Characteristics
● Standard Relays
Item
Number of poles
Contact resistance *1
Time *2
Set
Min. set pulse width
Time *2
Reset
Min. reset pulse
width
Max. operating Mechanical
frequency
Electrical
Insulation resistance *3
Between coil and
contacts
Between contacts
of different polarity
Dielectric
Between contacts
strength
of the same
polarity
Between set and
reset coils
Malfunction
Destruction
Shock
resistance
1-pole
2-pole
30 mΩ max.
50 mΩ max.
20 ms max.
30 ms
20 ms max.
30 ms
18,000 operations/hr
1,800 operations/hr
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min
3,000 VAC,
50/60 Hz for 1 min
−
1,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
1,000 m/s2
Set: 500m/s2 Armature OFF
Reset: 200m/s2 Contact OFF
10,000,000 operations min
(at 18,000 operations/hr)
100,000 operations min. (at 1,800
operations/hr under rated load)
-40°C to 70°C (with no icing or
condensation)
5% to 85%
Approx. 17 g
Destruction
Vibration
resistance
Malfunction
Mechanical
Durability
Electrical
Ambient operating temperature
Ambient operating humidity
Weight
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
*4. Value for quick-connect terminals.
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
■Engineering Data
AC resistive load
10
5
DC resistive load
AC
inductive load
(cosφ = 0.4)
G2R-1-E, G2R-1A-E
DC inductive load
(L/R = 7 ms)
1
G2R-1Z, G2R-1AZ
50
AC resistive load
16
10
5
DC resistive load
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
1
0
5
10
20 30 50 100
5
10
1
20 30 50 100
10
AC resistive load
5
DC resistive load
1
AC
inductive load
(cosφ = 0.4)
50
10
AC resistive load
5
DC resistive load
1
DC inductive load
(L/R = 7 ms)
0.5
G2R-2-H, G2R-2A-H
Switching current (A)
50
500
Switching voltage (V)
Switching voltage (V)
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A
AC
inductive load
(cosφ = 0.4)
0.5
DC inductive load
(L/R = 7 ms)
0.1
0.1
0
5
10
20 30 50 100
500
Switching voltage (V)
6
AC resistive load
5
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
0.1
0
500
10
0.5
0.1
0.1
50
DC resistive load
0.5
0.5
Switching current (A)
50
Switching current (A)
Switching current (A)
● Maximum Switching Capacity
Flux Protection/Plug-in Relays
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T
Switching current (A)
G
2
R
Double-winding Latching Relays
Item
Number of poles
1-pole
2-pole
Contact resistance *1
30 mΩ max.
50 mΩ max.
Operate time *2
15 ms max.
Release time *2
AC: 10 ms max.; DC: 5 ms max.
Max.
Mechanical
18,000 operations/hr
operating
Electrical
1,800 operations/hr
frequency
Insulation resistance *3
1,000 MΩ min.
Between coil and
5,000 VAC, 50/60 Hz for 1 min
contacts
Between contacts
3,000 VAC, 50/60 Hz
Dielectric
for 1 min
of different polarity
strength
Between contacts
of the same
1,000 VAC, 50/60 Hz for 1 min
polarity
10 to 55 to 10 Hz, 0.75 mm single
Destruction
amplitude (1.5 mm double amplitude)
Vibration
resistance
10 to 55 to 10 Hz, 0.75 mm single
Malfunction
amplitude (1.5 mm double amplitude)
Destruction
1,000 m/s2
Shock
200 m/s2 when energized;
resistance Malfunction
100m/s2 when no energized
AC coil: 10,000,000 operations min.;
Mechanical
DC coil: 20,000,000 operations min.
(at 18,000 operations/hr)
Durability
100,000 operations min.
Electrical
(at 1,800 operations/hr under rated load)
Ambient operating temperature
-40°C to 70°C (with no icing)
Ambient operating humidity
5% to 85%
Weight
Approx. 17 g (Approx. 20 g *4)
0
5
10
20 30 50 100
500
Switching voltage (V)
0
5
10
20 30 50 100
500
Switching voltage (V)
G2R
PCB Power Relay
G2RK-2A, G2RK-2
Switching current (A)
Switching current (A)
G2RK-1A, G2RK-1
50
10
AC resistive load
5
50
10
5
AC resistive load
3
AC
inductive load
(cosφ = 0.4)
DC resistive load
1
0.5
AC
inductive load
(cosφ = 0.4)
DC resistive load
1
0.5
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
0.1
0.1
5
10
20 30 50 100
500
0
5
10
20 30 50 100
Switching voltage (V)
G2R-24, G2R-2A4
50
AC resistive load
10
5
Switching current (A)
G2R-1Z4, G2R-1AZ4
50
10
AC resistive load
5
DC resistive load
1
AC
inductive load
(cosφ = 0.4)
1
DC inductive load
(L/R = 7 ms)
0.5
0.5
0.1
5
10
20 30 50 100
300 500
5
10
20 30 50 100
250 VAC/30 VDC
resistive load
250 VAC inductive load
(cosφ = 0.4)
30
10
5
500
300
250 VAC/30 VDC
resistive load
100
50
30
4
5
6
7.5 8
10
12
0
14
300
30 VDC inductive load (L/R = 7ms)
250 VAC/30 VDC
resistive load
30
10
5
500
300
100
30 VDC inductive load (L/R = 7ms)
50
250 VAC/30 VDC
resistive load
30
250 VAC inductive load
(cosφ = 0.4)
2
4
6
8
10
12
14
16
18
0
1
2
3
4
5
6
Switching current (A)
1,000
500
300
250 VAC/30 VDC
resistive load
100
30 VDC inductive load
(L/R = 7ms)
50
30
10
250 VAC inductive load
(cosφ = 0.4)
5
3
0
1,000
5
Switching current (A)
Durability (x104 operations)
Durability (x104 operations)
500
50
300 500
Switching voltage (V)
G2R-2-H, G2R-2A-H
1,000
100
20 30 50 100
3
Switching current (A)
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A
10
10
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7ms)
3
2
5
G2R-1Z, G2R-1AZ
1,000
5
3
0
0
10
30 VDC inductive load (L/R = 7ms)
G
2
R
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
Switching voltage (V)
Durability (x104 operations)
Durability (x104 operations)
500
50
300 500
G2R-1-E, G2R-1A-E
1,000
DC resistive load
0.1
0
● Durability
Flux Protection/Plug-in Relays
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T
100
AC resistive load
5
0.5
DC inductive load
(L/R = 7 ms)
Switching voltage (V)
300
10
1
0.1
0
50
AC
inductive load
(cosφ = 0.4)
DC resistive load
Durability (x104 operations)
Switching current (A)
Fully Sealed Relays
G2R-14, G2R-1A4
500
Switching voltage (V)
Switching current (A)
0
3
1
2
3
4
5
6
Switching current (A)
0
250 VAC inductive load
(cosφ = 0.4)
1
1.5
2
3
4
Switching current (A)
7
G2R
PCB Power Relay
G2RK-2A, G2RK-2
Durability (x104 operations)
1,000
500
300
100
250 VAC/30 VDC
resistive load
50
250 VAC inductive load
(cosφ = 0.4)
30
1,000
500
300
250 VAC/30 VDC
resistive load
100
30 VDC inductive load
(L/R = 7ms)
50
250 VAC inductive load
(cosφ = 0.4)
30
10
10
5
5
30 VDC inductive load (L/R = 7ms)
3
3
1
2
2.5
3 3.5
4
5
0
6
1
1.5
2
2.5
Switching current (A)
G
2
R
1,000
500
300
250 VAC/30 VDC
resistive load
250 VAC inductive load
(cosφ = 0.4)
50
30
G2R-1Z4, G2R-1AZ4
1,000
10
500
300
30 VDC inductive load (L/R = 7ms)
100
50
250 VAC/30 VDC
resistive load
30
5
3
500
300
30 VDC inductive load (L/R = 7ms)
100
2
4
6
8
10
30
10
250 VAC inductive load
(cosφ = 0.4)
5
1
1.5
2
2.5 3
4
Switching current (A)
Must-operate/must-release voltage (On the basis of rated voltage) (%)
200
DC coil
170
150
140
110
100
AC coil
50
40
50
60
70
80
0
6
● Ambient Temperature vs. Must
Operate and Must Release Voltage
G2R-1
250
30
5
1
2
3
4
Switching current (A)
● Ambient Temperature vs. Maximum
Coil Voltage
20
250 VAC inductive load
(cosφ = 0.4)
3
0
12
250 VAC/30 VDC
resistive load
50
3
0
Maximum coil voltage (%)
1,000
10
30 VDC inductive load (L/R = 7ms)
5
0
−25
4
G2R-24, G2R-2A4
Durability (x104 operations)
Durability (x104 operations)
Fully Sealed Relays
G2R-14, G2R-1A4
100
3
Switching current (A)
Durability (x104 operations)
0
90 100
100
80
max.
X
60
min.
40
max.
X
20
0
−60
min.
−40
−20
Ambient temperature (°C)
0
20
40
60
6
G2R-2
Must operate voltage
Must release voltage
Sample: G2R-1
Number of Relays: 5 pcs
5
Switching current (A)
80
Must-operate/must-release voltage (On the basis of rated voltage) (%)
Durability (x104 operations)
G2RK-1A, G2RK-1
100
Must operate voltage
Must release voltage
Sample: G2R-2
Number of Relays: 5 pcs
80
max.
X
60
min.
40
max.
X
min.
20
0
−60
−40
−20
Ambient temperature (°C)
0
20
40
60
80
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power voltage,
not a continuous voltage.
SPST-NO (1a)
SPST-NC (1c)
Y
1,000
800
600
X
400
200
200
400
Z
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directions three times
each with and without
Z'
energizing the Relays
to check the number
of contact
malfunctions.
Requirement:
200 m/s2 when
energized; 100m/s2
when de-energized
X'
600
Shock direction
X'
X
800
SPST-NO (1a) Y 1,000
SPST-NC (1c)
800
600
X
400
200
270
200
400
Z
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directions three times
each with and without
Z'
energizing the
Relays to check the
number of contact
malfunctions.
Requirement:
200 m/s2 when
energized; 100m/s2
when de-energized
X'
600
800
Y'
Z
Z'
Unit: m/s2
Y'
Shock direction
X'
X
160 Number of Relays: 50 pcs
Measurement: after the relay kept static by
140 applying a rated voltage, leave the relay at room
temperature of 20°C to 30°C, and high temperature
of 80°C ± 2°C respectively, to measure how the
120 keep-power varies with time.
MAX Room
MIN temperature
100
)
80
MAX
MIN
)
60
High
temperature
40
Y
Y
1,000
● Keep-power decrement with time
G2RK-1
G2R-2 Number of Relays: 5 pcs
Decrement of keep-power (%)
● Shock Malfunction
G2R-1 Number of Relays: 5 pcs
1,000
Y'
Z
Z'
Unit: m/s2
Y'
20
0
50 100
500 1,000
5,000 10,000
Elapsed time (H)
8
G2R
PCB Power Relay
■Dimensions
Relays with PCB Terminals
(SPDT (1c) Relays)
G2R-1(-Z)
G2R-1Z
G2R-1-H
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
13 max.
(12.7)*
29 max.
(28.8)*
3.5
3.5
(2.7)
25.5 max.
(25.3)*
1
2
3
7.5
Five, 1.3-dia.
holes
(0.3)
(2.1)
4
0.5
0.5**
5
20
4
(No coil polarity)
1
0.3
This illustration is the
G2R-1 model.
0.16
Relays with PCB Terminals
(SPST-NO (1a) Relays)
G2R-1A(-Z)
G2R-1AZ
G2R-1A-H
** Average value
** 0.3 (-H Type)
13 max.
(12.7)*
29 max.
(28.8)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
3.5
(2.7)
25.5 max.
(25.3)*
1
3
7.5
Four, 1.3-dia.
holes
(0.3)
(2.1)
0.3
4
0.5**
0.16
This illustration is the
G2R-1A model.
5
20
G
2
R
4
(No coil polarity)
1
** Average value
** 0.3 (-H Type)
Relays with PCB Terminals
(SPDT (1c) /High-capacity Relays)
G2R-1-E(Z)
13 max.
(12.6)*
29 max.
(28.6)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Eight, 1.3-dia. holes
2.5
2.5
(2.7)
25.5 max.
(24.9)*
1
2
3
4
8
7
6
5
7.5
(0.3)
(No coil polarity)
4
0.5
0.3
1
(2.1)
0.3
0.16
* Average value
Relays with PCB Terminals
(SPST-NO (1a)/High-capacity Relays)
G2R-1A-E(Z)
5
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
13 max.
(12.6)*
29 max.
(28.6)*
5
2.5
Six, 1.3-dia. holes
2.5
(2.7)
25.5 max.
(24.9)*
1
3
4
8
6
5
7.5
(0.3)
(No coil polarity)
4
0.3
1
(2.1)
0.3
0.16
20
5
(2.1)
* Average value
Note: Orientation marks are indicated as follows:
9
G2R
PCB Power Relay
Relays with PCB Terminals
(SPDT (1c) Relays)
G2R-14(-Z)(-U)
G2R-1Z4
13.5 max.
(12.9)*
29 max.
(28.6)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
3.5
3.5
25.5 max.
(24.8)*
(2.7)
1
2
3
7.5
Five, 1.3-dia.
holes
4
0.5
0.5
1
(2.1)
5
20
(No coil polarity)
0.3
0.16
Relays with PCB Terminals
(SPST-NO (1a) Relays)
G2R-1A4(-Z)(-U)
G2R-1AZ4
4
* Average value
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
13.5 max.
(12.9)*
29 max.
(28.6)*
3.5
25.5 max.
(24.8)*
(2.7)
1
3
7.5
Four, 1.3-dia.
holes
4
0.5
0.3
0.16
(2.1)
5
20
(No coil polarity)
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
13 max.
(12.8)*
3.5
3.5
(2.7)
25.5 max.
(25.2)*
−
+
7.5
(0.3)
Seven, 1.3-dia.
holes
0.5
0.3
1
4
1
(2.1)
5
1
−
S
+
7
2
3
4
R
6
5
(After confirming coil
polarity, wire correctly.)
20
* Average value
Double-winding Latching Relays with
29 max.
PCB Terminals
(28.8)*
(SPST-NO (1a) Relays)
G2RK-1A
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
13 max.
(12.8)*
3.5
25.5 max.
(25.2)*
−
(2.7)
+
7.5
(0.3)
Six, 1.3-dia.
holes
0.3
1
4
4
* Average value
Double-winding Latching Relays with
29 max.
PCB Terminals
(28.8)*
G (SPDT (1c) Relays)
2 G2RK-1
R
1
1
0.5
0.16
(2.1)
5
1
−
S
+
7
2
4
R
6
5
(After confirming coil
polarity, wire correctly.)
20
* Average value
Double-winding Latching Relays with PCB Terminals
(DPDT (2c) Relays)
13 max.
G2RK-2
(12.8)*
29 max.
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Ten, 1.3-dia. holes
2.5
(28.8)*
2.5
(2.7)
25.5 max.
(25.3)*
7.5
1
−
S
+
+
10
2
3
4
5
8
7
6
−
R
9
(0.3)
(2.7)
4
0.3
1
0.18
0.18
1
0.15
* Average value
(2.1)
5
5
5
(After confirming coil
polarity, wire correctly.)
(2.1)
20
Double-winding Latching Relays with PCB Terminals
(DPST-NO (2a) Relays)
13 max.
(12.8)*
G2RK-2A
29 max.
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Eight, 1.3-dia. holes
2.5
(28.8)*
2.5
(2.7)
25.5 max.
(25.3)*
7.5
1
−
S
+
+
10
2
4
5
7
6
−
R
9
(0.3)
(2.7)
4
0.3
1
0.18
0.15
(After confirming coil
polarity, wire correctly.)
1
(2.1)
* Average value
5
5
(2.1)
20
Note: Orientation marks are indicated as follows:
10
G2R
PCB Power Relay
Relays with PCB Terminals
(DPDT (2c) Relays)
G2R-2(-Z)
G2R-2-H
13 max.
(12.7)*
29 max.
(28.8)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Eight, 1.3-dia. holes
2.5
2.5
(2.7)
25.5 max.
(25.2)*
1
2
3
4
8
7
6
5
7.5
(0.3)
(No coil polarity)
4
0.5
0.5
1
0.3
(2.1)
0.15
Relays with PCB Terminals
(DPST-NO (2a) Relays)
G2R-2A
G2R-2A-H
G2R-2A-Z
5
* Average value
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
13 max.
(12.7)*
29 max.
(28.8)*
5
Six, 1.3-dia. holes
2.5
2.5
(2.7)
25.5 max.
(25.2)*
1
3
4
8
6
5
7.5
(0.3)
4
0.5
0.3
(No coil polarity)
1
20
(2.1)
0.15
5
G
2
R
(2.1)
* Average value
Relays with PCB Terminals
(DPDT (2c) Relays)
G2R-24(-Z)(-U)
13.5 max.
(12.8)*
29 max.
(28.6)*
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Eight, 1.3-dia. holes
2.5
2.5
(2.7)
25.5 max.
(24.7)*
1
2
3
4
8
7
6
5
7.5
(No coil polarity)
4
0.5
0.5
1
0.3
(2.1)
0.15
5
* Average value
Relays with PCB Terminals
(DPST-NO (2a) Relays)
G2R-2A4(-Z)(-U)
(2.1)
20
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
13.5 max.
(12.8)*
29 max.
(28.6)*
5
Six, 1.3-dia. holes
2.5
2.5
(2.7)
25.5 max.
1
3
4
6
5
7.5
8
4
0.5
0.3
(No coil polarity)
1
(2.1)
0.15
20
5
(2.1)
* Average value
Note: Orientation marks are indicated as follows:
11
G2R
PCB Power Relay
Relays with Quick-connect
Terminals
(SPDT (1c) Relays)
7.5
G2R-1-T
30.5 max.
(29.7)*
5.2
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
5.2
17.5
* Average value
Five, 1.3-dia. holes
4.75
0.5
38
Two M3 or
two 3.5 dia.
1
8.5
2
4
3
5
29.5 max.
(No coil polarity)
Note: Model number of
quick-connect terminal is 187.
2.5
Relays with Quick-connect
Terminals
(SPST-NO (1a) Relays)
7.5
G2R-1A-T
45 max.
(43.9)*
14 max.
(13.1)*
30.5 max.
(29.7)*
5.2
17.4
G
2
R
Four, 1.3-dia. holes
4.75
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
* Average value
38
0.5
Two M3 or
two 3.5 dia.
1
4
8.5
3
5
Note: Model number of
quick-connect terminal is 187.
29.5 max.
2.5
45 max.
(43.9)*
(No coil polarity)
14 max.
(13.1)*
Note: Orientation marks are indicated as follows:
12
G2R
PCB Power Relay
■Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
File No. E41643
CSA Certified:
File No. LR31928
UL Recognized:
1-pole
1-pole
Model
Contact
form
Coil ratings
G2R-1A
G2R-1A4
G2R-1A-H
SPST-NO
(1a)
G2R-1
G2R-14
G2R-1-H
SPDT
(1c)
G2R-1AZ4
G2R-1Z
G2R-1Z4
G2R-1A-E
G2R-1-E
10 A, 250 VAC (General
Use) at 40°C
100,000
SPDT
(1c)
SPST-NO
(1a)
SPDT
(1c)
G2R-1A-H
6,000
G2R-1
5 A, 30 VDC (Resistive)
at 40°C
Contact
form
DPST-NO
(2a)
G2R-2A-H
TV-3 (N. O. only) at
40°C
10 A, 250 VAC (General
3 to 120 VDC Use) at 40°C
6 to 240 VAC 5 A, 30 VDC (Resistive)
at 40°C
16 A, 250 VAC (General
Use) at 40°C
3 to 120 VDC 16 A, 30 VDC
6 to 240 VAC (Resistive) at 40°C
TV-3 (N. O. only) at
40°C
G2R-24
G2R-24-H
Coil ratings
Contact ratings
5 A, 250 VAC (General
Use) at 40°C
100,000
G2R-14
G2R-1-H
DPDT
(2c)
Number of
test
operations
10 A, 250 VAC (General
Use) at 40°C
100,000
100,000
TV-3 (N. O. only) at
40°C
25,000
25,000
G2R-1AZ
G2R-1Z
6,000
G2R-1Z4
G2R-1A-E
SPST-NO
(1a)
SPDT
(1c)
SPST-NO
(1a)
30,000
6,000
25,000
G2R-1-E
Number of
test
operations
6,000
SPDT
(1c)
100,000
5 A, 250 VAC (General
3 to 110 VDC Use) at 40°C
3 to 240 VAC 5 A, 30 VDC (Resistive)
at 40°C
16 A, 250 VAC (General
Use) at 40°C
3 to 110 VDC 16 A, 30 VDC
3 to 240 VAC (Resistive) at 40°C
TV-3 (N. O. only) at
40°C
25,000
6,000
6,000
25,000
2-pole
Contact
form
Coil ratings
G2R-2A
G2R-2A4
G2R-2A-H
G2R-24
Contact ratings
5 A, 250 VAC (General
Use) at 40°C
DPST-NO
(2a)
3 to 110 VDC 5 A, 30 VDC (Resistive)
3 to 240 VAC at 40°C
DPDT
(2c)
TV-3 (N. O. only) at
40°C
G2R-24-H
TV-3 (N. O. only) at
40°C
Contact ratings
3 to 110 VDC
3 to 240 VAC 10 A, 30 VDC
(Resistive) at 40°C
SPDT
(1c)
G2R-2
3 to 120 VDC 5 A, 30 VDC (Resistive)
6 to 240 VAC at 40°C
G2R-2
Coil ratings
SPST-NO
(1a)
G2R-1A-T
Model
G2R-2A
G2R-2A4
G2R-1A4
G2R-1AZ4
SPST-NO
(1a)
Contact
form
G2R-1A
2-pole
Model
Model
G2R-1-T
G2R-1-T
G2R-1AZ
Number of
test
operations
5 A, 277 VAC (General
Use) at 40°C
3 to 120 VDC
6 to 240 VAC
G2R-1A-T
Contact ratings
Number of
test
operations
6,000
100,000
25,000
EN/IEC, VDE Certified: Registration No. 40015012
Note: Consult separately for UL/CSA contact standard ratings.
Model
Contact
form
G2R-1(A)-E
1
3 to 110 VDC 16 A, 250 VAC
12 to 240 VAC (cosφ = 1.0) at 70°C
1
10 A, 250 VAC
5 to 110 VDC (cosφ = 1.0) at 40°C
12 to 240 VAC 10 A, 30 VDC (0 ms) at
40°C
G2R-( )
2
Coil ratings
Contact ratings
Number of
test
operations
100,000
5 A, 250 VAC
5 to 110 VDC (cosφ = 1.0) at 40°C
12 to 240 VAC 5 A, 30 VDC (0 ms) at
40°C
EN, TÜV Certified: Registration No. R50030327
Model
Contact
form
G2R-1(A)-E
1
3 to 120 VDC 16 A, 250 VAC
6 to 240 VAC (cosφ = 1.0) at 70°C
1
10 A, 250 VAC
3 to 120 VDC (cosφ = 1.0) at 70°C
6 to 240 VAC 10 A, 30 VDC (0 ms) at
70°C
G2R-( )
2
Coil ratings
Contact ratings
Number of
test
operations
100,000
5 A, 250 VAC
3 to 120 VDC (cosφ = 1.0) at 40°C
6 to 240 VAC 5 A, 30 VDC (0 ms) at
40°C
13
G
2
R
G2R
PCB Power Relay
■Precautions
● Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
● Mounting
• When mounting a number of relays on
a PCB, be sure to provide a minimum
mounting space of 5 mm between the
two juxtaposed relays as shown
below.
5 mm
min.
Type
#187
(Width
4.75)
5 mm min.
G
2
R
Refer to the following table for
examples of positive-lock connectors
made by AMP. Contact the
manufacturer directly for details on
connectors including availability.
● Handling
• The terminals are compatible with
Faston receptacle #187 and are
suitable for positive-lock mounting.
Use only Faston terminals with the
specified numbers.
Select leads for connecting Faston
receptacles with wire diameters that
are within the allowable range for the
load current.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Also, do not insert terminals at an
angle, or insert/remove multiple
terminals at the same time. Be sure to
insert and remove terminals carefully
one at a time.
Receptacle
terminals
AMP170330-1
(170324-1)
AMP170331-1
(170325-1)
AMP170332-1
(170326-1)
Positive housing
AMP172074-1
(natural color)
AMP172074-4
(yellow)
AMP172074-5
(green)
AMP172074-6
(blue)
Note: The numbers shown in parentheses are for
air-feeding.
● Minimum Pulse Width of Doublewinding Latching Relays
• The minimum pulse width shown in
the table of characteristics are values
measured under conditions of ambient
temperature at 23°C with rated
operating voltage imposed on coil. The
Relay may not provide a satisfactory
performance as its holding ability
decreases depending on the operating
circuit conditions and ambient
temperature, or decreases due to
degradation over time.
In actual operation, impose to the coil
a rated operating voltage with a pulse
width that is suitable to the actual load,
and reset the setting at least once a
year, to correspond to the degradation
over time.
• When using the Relay in a strong
magnetic field environment, the
magnetic body may be demagnetized
due to the influence of environment,
causing the Relay to malfunction.
Therefore, do not use the Relay in a
strong magnetic field environment.
● Degradation over Time of Doublewinding Latching Relays Holding
Ability
• If a double-winding latching Relay is
used left set for an extended period,
changes over time will degrade the
magnetic force, and the reduction in
holding ability may cause the set
status to be released. This is also
because of the properties of semihard magnetic material, and the rate
of degradation over time depends on
the ambient environment (e.g.,
temperature, humidity, vibration, and
presence or absence of external
magnetic fields).Perform maintenance
at least once a year by resetting,
applying the rated voltage again, and
then setting.
● Wiring High Capacity (-E) Models
• High-capacity models (-E) have a
structure that connects two terminals
from one contact.
When designing the circuit, use both
terminals.
If you use only one terminal, the relay
may be unable to satisfy specified
performance.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
14
Contact: www.omron.com/ecb
Cat. No. K013-E1-13
0812(0207)(O)
Similar pages