MHI200GRI8 Series Compact, 2W MiniDIP Ultra-High Isolation DC/DC Converters Electrical Specifications Key Features: • 2W Output Power Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions • 15 kV/µS CMTI • EN 60950 Approved (Pend.) • Reinforced Insulation Typ. Max. 5 VDC Input 4.5 5.0 5.5 12 VDC Input 10.8 12.0 13.2 24 VDC Input 21.6 24.0 26.4 • 8.0 kV Isolation Input Voltage Range Min. Input Filter Units VDC Capacitor Filter Output • Compact MiniDIP Case Parameter • -25°C to +80°C Operation Output Voltage Accuracy Conditions • Industry Standard Pin-Out Output Voltage Balance Line Regulation Load Regulation, See Note 2 Min. Typ. Max. Units ±2.0 ±4.0 % Dual Output, Balanced Loads ±0.1 ±1.0 % VIN = Min to Max ±1.2 ±1.5 % 150 mV P - P ±0.02 %/°C See Model Selection Guide Ripple & Noise (20 MHz) See Note 3 Temperature Coefficient ±0.01 Output Short Circuit Momentary (0.5S Max) General Parameter Conditions Isolation Voltage Min. Typ. Max. Units Rated For 60 Sec 4,000 VAC rms Tested For 1 Sec 8,000 VDC Isolation Resistance 500 VDC Isolation Capacitance 10 100 kHz, 1V G 15 20 pF Common Mode Transient Immunity 15 kV/µS Switching Frequency 50 80 100 kHz Min. Typ. Max. Units -25 +25 +80 Environmental Parameter Conditions Ambient Operating Temperature Range Case Storage Temperature Range +105 -50 Cooling °C +125 °C 95 % Free Air Convection Humidity RH, Non-condensing Physical Case Size See Mechanical Diagram (Page 2) Case Material Non-Conductive Black Plastic (UL94-V0) MicroPower Direct Weight 292 Page Street Suite D Stoughton, MA 02072 USA 0.17 Oz (5.1g) Reliability Specifications Parameter Conditions MTBF MIL HDBK 217F, 25°C, Gnd Benign Safety Standards T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Min. Typ. Max. 2.0 Units MHours UL 60950, EN 60950 (Pending) Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (0.1 Sec) Lead Temperature Min. Typ. Max. 5 VDC Input 9.0 12 VDC Input 18.0 24 VDC Input 30.0 1.5 mm From Case for 10 Sec 260 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units VDC °C www.micropowerdirect.com Model Selection Guide Model Number MHI205S-05GRI8 MHI205S-12GRI8 MHI205S-15GRI8 MHI205D-12GRI8 MHI205D-15GRI8 MHI212S-05GRI8 MHI212S-12GRI8 MHI212S-15GRI8 MHI212D-12GRI8 MHI212D-15GRI8 MHI224S-05GRI8 MHI224S-12GRI8 MHI224S-15GRI8 MHI224D-12GRI8 MHI224D-15GRI8 Input Output Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 5 4.5 - 5.5 615 60 5 4.5 - 5.5 609 60 5 4.5 - 5.5 605 60 5 4.5 - 5.5 553 60 5 4.5 - 5.5 542 60 12 10.8 - 13.2 256 30 12 10.8 - 13.2 254 30 12 10.8 - 13.2 252 30 12 10.8 - 13.2 224 30 12 10.8 - 13.2 220 30 24 21.6 - 26.4 128 15 24 21.6 - 26.4 127 15 24 21.6 - 26.4 126 15 24 21.6 - 26.4 112 15 24 21.6 - 26.4 110 15 Voltage Current Current (VDC) (mA, Max) (mA, Min) 5.0 12.0 15.0 ±12.0 ±15.0 5.0 12.0 15.0 ±12.0 ±15.0 5.0 12.0 15.0 ±12.0 ±15.0 Notes: 1. The specified maximum capacitive load is for each output. 2. Load regulation is measured over a range of 20% IOUT to 100% IOUT. 3. When measuring output ripple & noise, it is recommended that an external capacitor (3.3 µF typ.) be placed from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models. 4. The converter should be connected to a low ac-impedance source. A source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (<1.0⍀ at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 2.2 µF is recommended; for 12V input units, a 1.0 µF; and for 24V units a 0.47 µF. 5. Operation at no-load will not damage the unit, but they may not meet all specifications. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection tables for the correct rating. 400 165 133 ±83 ±66 400 165 133 ±83 ±66 400 165 133 ±83 ±66 Fuse Capacitive Load Rating Efficiency Regulation Load (%, Typ) Slow-Blow (%, Max) (µF, Max) 8.0 3.0 2.5 ±1.5 ±1.0 8.0 3.0 2.5 ±1.5 ±1.0 8.0 3.0 2.5 ±1.5 ±1.0 (mA) 65 65 66 72 73 65 65 66 74 75 65 65 66 74 75 ±12.0 ±10.0 ±10.0 ±10.0 ±10.0 ±12.0 ±10.0 ±10.0 ±10.0 ±10.0 ±12.0 ±10.0 ±10.0 ±10.0 ±10.0 330 330 330 100 100 330 330 330 100 100 330 330 330 100 100 1,200 1,200 1,200 1,200 1,200 600 600 600 600 600 250 250 250 250 250 Derating Curve IGBT Applications Notes: The MHI200x-xxD series is a good choice for applications involving high speed switching, such as driving IGBTs. They are designed to withstand the extra stress caused by the high voltage switching transients present in IGBT drive circuits. All of the MHIxxx series have isolation levels that range from 5.2 to 8 kV. Many of these have reinforced insulation. The high isolation levels (and the correspondingly low capacitive coupling rates) allow them to be safely used in applications with highly dynamic switched AC or DC. Mechanical Dimensions Pin Connections Pin 1 7 8 9 10 16 Pin 1 7 8 9 10 16 Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) Single Output -VIN No Connection No Connection +VOUT -VOUT +VIN Dual Output -VIN No Connection Common +VOUT -VOUT +VIN MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]