Total Power MIW3123 Dip-24 plastic package Datasheet

FEATURES
►DIP-24 Plastic Package
►Wide 2:1 Input Range
►High Efficiency up to 86%
►Operating Temp. Range –40°C to +85°C
►Short Circuit Protection
►I/O-isolation 1500VDC
►Cost optimized Design
►3 Years Product Warranty
PRODUCT OVERVIEW
The MIW3100 series is a range of isolated 6W DC/DC converter modules featuring fully regulated output voltages and wide 2:1 input voltage ranges.
The product comes in a DIP-24 plastic package with industry standard pinout. An excellent efficiency allows an operating temperature range of –40°C
to +85°C.These DC/DC converters offer an economical solution for many cost critical applications in battery-powered equipment and instrumentation.
Model Selection Guide
Model
Input
Output
Output
Number
Voltage
Voltage
Current
(Range)
VDC
MIW3121
MIW3122
MIW3123
MIW3126
MIW3127
MIW3131
MIW3132
MIW3133
MIW3136
MIW3137
12
(9 ~ 18)
24
(18 ~ 36)
VDC
3.3
5
12
±12
±15
3.3
5
12
±12
±15
Input Current
Reflected
Max. capacitive
Ripple
Load
Max.
Min.
@Max. Load
@No Load
Current
mA
1200
1000
500
±250
±200
1200
1000
500
±250
±200
mA
60
50
25
±12.5
±10
60
50
25
±12.5
±10
mA(typ.)
429
514
595
595
595
209
251
291
291
291
mA(typ.)
mA(typ.)
20
25
(typ.)
@Max. Load
uF
6800
1000#
6800
5
Efficiency
15
1000#
%
77
81
84
84
84
79
83
86
86
86
# For each output
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
Under Voltage Shutdown
Reverse Polarity Input Current
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI (with suffix A only)
In
Total Power International,
Inc
Model
12V Input Models
24V Input Models
12V Input Models
24V Input Models
12V Input Models
24V Input Models
All Models
Min.
-0.7
-0.7
Typ.
Max.
Unit
25
--50
--6
8
4.5
VDC
8
12
16
----8
----16
----1
A
--1000
3000
mW
----2500
mW
Compliance to EN 55022,class A and FCC part 15,class A
Toll Free: 877-646-0900
www.total-power.com
MIW3100 SERIES
Tota
Total Power International, Inc.
DC/DC CONVERTER 6W, DIP-Package
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Conditions
Min.
--------------------120
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=20% to 100%
Over Line, Load & Temp.
25% Load Step Change
Foldback
Typ.
±0.5
±0.5
±0.1
±0.3
50
----150
±2
±0.01
150
Max.
±1.0
±2.0
±0.3
±1.0
75
100
15
300
±6
±0.02
---
Unit
%
%
%
%
mV P-P
mV P-P
mV rms
uS
%
%/℃
%
Continuous
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
380
500
pF
---
300
---
KHz
MIL-HDBK-217F@25℃, Ground Benign
1,000,000
---
---
Hours
I/O Isolation Voltage (rated)
Switching Frequency
MTBF (calculated)
Safety Approvals
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Input Fuse
12V Input Models
24V Input Models
1500mA Slow-Blow Type
700mA Slow-Blow Type
Environmental Specifications
Parameter
Conditions
Min.
Max.
Ambient
-40
+85
℃
Case Temperature
---
+90
℃
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Operating Temperature Range (with Derating)
Cooling
Free-Air convection
Lead Temperature (1.5mm from case for 10Sec.)
---
Power Derating Curve
100
Natural
convection
80
100LFM
200LFM
60
400LFM
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature ]
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Unit
MIW3100 SERIES
Total Power International, Inc.
Tota
DC/DC CONVERTER 6W, DIP-Package
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
3
Ripple & Noise measurement bandwidth is 0-20MHz.
4
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
5
All DC/DC converters should be externally fused at the front end for protection.
however they may not meet all specifications listed.
6
Other input and output voltage may be available, please contact factory.
7
To order the converter with input filter meeting EN55022, Class A , add suffix A (e.g. MIW3121A) to order code.
8
Specifications subject to change without notice.
Package Specifications
3
9
11
Bottom View
23 22
16
15.24 [0.60]
2.54
[0.10]
31.8 [1.25]
Dual Output
-Vin
3
-Vin
-Vin
9
No Pin
Common
11
NC
-Vout
14
+Vout
+Vout
16
-Vout
Common
22
+Vin
+Vin
23
+Vin
+Vin
NC: No Connection
14
5.08 4.5
[0.20][0.18]
2.54
[0.10]
2
Pin Connections
Pin
Single Output
2
-Vin
20.3 [0.80]
0.50 [0.02]
15.22 [0.60]
4.1
[0.16]
10.2
[0.40]
Mechanical Dimensions
►All
dimensions in mm (inches)
►Tolerance: X.X±0.25
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
diameter  0.5 ±0.05 (0.02±0.002)
Physical Characteristics
ase Size
:
31.8x20.3x10.2mm (1.25x0.80x0.40 Inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Weight
:
16.9g
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
MIW3100 SERIES
Total Power International, Inc.
Tota
DC/DC CONVERTER 6W, DIP-Package
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance.
Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Design & Feature Considerations
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 3.3uF for the 12V input devices and a 2.2uF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3uF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
Com.
DC / DC
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
MIW3100 series have limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 1000uF maximum capacitive load for dual outputs and 6800uF capacitive load
for single outputs. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃.
The derating curves are determined from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
50mm / 2in
15mm / 0.6in
In
Total Power International,
Inc
Air Flow
DUT
Toll Free: 877-646-0900
www.total-power.com
Similar pages