H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME AND ACTIVE CURRENT SHARING MULTI-OUTPUT 200 WATTS INTERNAL SWITCHING POWER SUPPLIES HVP200 SERIES FEATURES: ACCOMMODATE UNIVERSAL AC SOURCES MEET IEC 61000-3-2 HARMONIC CORRECTION THIRD-WIRE LOADING SHARING MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB.22 CLASS B +5V STAND-BY GREEN POWER CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: Molex #5273 V-M connector. Input Frequency: 47-63Hz. Inrush Current: Typ. 33A @230Vac. Input Current: 2.25A @115Vac, 1.0 A@230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet CISPR PUB.22 Class B. Hold-up Time: 18mS @115Vac & 230Vac. Power Fail Signal: Installed. DC OK Signal: Installed in VO1 & VO2. Power Factor Correction: Meet Harmonic Correction per IEC 61000-3-2 PF typ. 0.97-0.99. Remote Inhibit: Installed. Enable active high. Over Temperature Protection: Thermostat @ 95°C. Earth Leakage: Less than 0.75mA. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: Molex #5273 V-M connector. Output Wattage: Convection 150 watts. With 30 cfm forced air 200W. Line Regulation: Typ. 0.1%. Load Regulation: Main O/P VO1: Typ. ±1.0%. Aux. O/P VO2: Typ. ±1.0%. (Magnetic Amp). Aux. O/P VO3,4,5: Typ. ±2-3.0%. (P.R.). Stand-By Green Power: +5V/50mA available. Noise & Ripple: Typ. 1.0% peak to peak. OVP: Available at VO1 & VO2. Remote Sense: Installed in VO1 & VO2. Adjustability: Available at VO1 & VO2. Load Sharing: Active current sharing circuit at VO1. Overload Protection (OLP): Fully protected against output overload and short circuit. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typ. 65-70%. Switching Frequency: Fixed frequency at 70K Hz. Circuit Topology: PWM fixed-frequency forward circuit. Transient Response: Output voltage returns in less than 3mS following a 25% load change. Safety Standard: UL 60950-1/EN 60950-1 Class I. Power Density: 3.0 Watts / Cubic Inch. Operating Temperature: 0 to +50°C under forced air flow for full load. Storage Temperature: -20 to +85°C. Temperature Coefficient: Typ. ±0.04%/ °C. Cooling: 30 cfm air flow is required to deliver the full power 200W. Construction: U-bracket construction format. Note: Due to requests in market and advances in technology, specifications subject to change without notification. For the details of safety approval, please consult the factory. -53- OUTPUT VOLTAGE / CURRENT RATINGS CHART DUAL OUTPUT (Under forced air cooling) MODEL NO. HVP200-20 HVP200-21 HVP200-22 HVP200-23 HVP200-290A HVP200-290B HVP200-291 HVP200-292 HVP200-293 MAIN VO1 @★#≡ Typ. Volt. 25.0A +5.0V 25.0A +5.0V 25.0A +5.0V 25.0A +5.0V 25.0A +5.0V 30.0A +3.3V 30.0A +3.3V 30.0A +3.3V 30.0A +3.3V TRIPLE OUTPUT (Under forced air cooling) AUX. +VO2 @★#▲ Typ. Volt. 10.0A +5.0V 5.0A +12.0V 4.0A +15.0V 2.5A +24.0V 15.0A +3.3V 15.0A +5.0V 5.0A +12.0V 4.0A +15.0V 2.5A +24.0V MODEL NO. HVP200-30 HVP200-31 HVP200-32 HVP200-33 MAIN VO1 @★#≡ Typ. Volt. 25.0A +5.0V 25.0A +5.0V 25.0A +5.0V 25.0A +5.0V AUX. VO2 @★#▲ Typ. Volt. 4.0A +12.0V 4.0A +12.0V 10.0A +3.3V 10.0A +3.3V AUX. VO3◇■● Typ. Volt. 1.0A 12.0V 2.0A 5.0V 1.0A 12.0V 1.0A 15.0V QUAD OUTPUT (Under forced air cooling) MODEL NO. HVP200-40 HVP200-41 HVP200-42 HVP200-43 HVP200-490A HVP200-490B HVP200-491A HVP200-491B MAIN VO1 @★#≡ Typ. Volt. 20.0A +5.0V 20.0A +5.0V 20.0A +5.0V 20.0A +5.0V 20.0A +5.0V 20.0A +3.3V 20.0A +5.0V 20.0A +3.3V AUX. VO2 @★#▲ Typ. Volt. 4.0A +12.0V 4.0A +12.0V 2.0A +24.0V 3.5A +15.0V 15.0A +3.3V 15.0A +5.0V 15.0A +3.3V 15.0A +5.0V AUX. VO3◇■● Typ. Volt. 3.0A 12.0V 3.0A 5.0V 3.0A 12.0V 3.0A 12.0V 3.0A 12.0V 3.0A 12.0V 2.5A 15.0V 2.5A 15.0V AUX. VO4 Typ. 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 2.5A 2.5A ◇■● Volt. 12.0V 5.0V 12.0V 12.0V 12.0V 5.0V 15.0V 15.0V PENTAD OUTPUT (Under forced air cooling) MAIN VO1 @★#≡ AUX. VO2 @★#▲ AUX. VO3 ◇■● AUX. ◇VO4 ■● AUX. VO5 ■● Typ. Typ. Typ. Typ. Typ. Volt. Volt. Volt. Volt. Volt. 20.0A 12.0A 1.0A 1.0A 1.0A HVP200-590 +3.3V +5.0V 12.0V 12.0V +15.0V 20.0A 5.0A 1.0A 1.0A 2.0A HVP200-591 +3.3V +12.0V 12.0V 12.0V +5.0V 20.0A 12.0A 1.0A 1.0A 1.0A HVP200-592 +3.3V +5.0V 15.0V 15.0V +12.0V 8.0A 5.0A 3.0A 3.0A 2.0A HVP200-593 +3.3V +12.0V 12.0V 12.0V +5.0V Symbol: "★" OVP built-in. "@" Adjustable. "■" Couple filter inductor. "#" Remote sensing. "◇" Floating (or isolated) output. "●" Installed with Post Regulator (P.R.). "▲" Installed with magnetic amplifier. "≡" Active current sharing. MODEL NO. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 1,164.0g (41.0 Oz.) INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT DUAL/TRIPLE/QUAD/PENTAD OUTPUT ASSIGNMENT AC-L AC-N AC-G +VO1 CNTR & PIN# P1-L P1-N P1-G P2-1, 2,3 DCCOM P2-4, 5,6,7 VO2 P2-8, 9,10 VO5 VO3 P3-1,2 P3-3,4 ASSORTED SIGNALS VO4 -VO3 P3-9, 10 P3-5,6 P3-7,8 Mating connector: P1,2,3 Molex # 5195 or 5239 series. P4 Molex # 5264 series or equivalent. -54- -VO4 DCPower Enable COM Fail DCOK +5V S. B. VO1 VO1 VO1 ≡ +S –S VO2 +S VO2 -S P4-5 P4-2 P4-4 P4-7 P4-8 P4-10 P4-9 P4-3 P4-1 P4-6