Murata G5Q-1A4-DC24 Compact, high isolation relay Datasheet

PCB Relay
G5Q
Compact, High Isolation Relay
• Compact single pole relay with high isolation between
coil and contacts.
• Ensures a withstand impulse voltage of 8,000V between
the coil and contacts.
• Low coil power consumption.
• UL class F coil insulation.
• UL recognized / CSA certified. EN approved.
• Ideal for appliance and HVAC controls
• RoHS Compliant
Ordering Information
To Order: Select the part number and add the desired coil voltage and rating. (e.g., G5Q-14 DC12)
Classification
Single contact, class F coil insulation
SPST-NO
SPDT
Enclosure rating
Model
Vented
G5Q-1A
Sealed
G5Q-1A4
Vented
G5Q-1
Sealed
G5Q-14
Note: Add “-EU” before the coil voltage to obtain versions with CTI > 250. (e.g., G5Q-1A4-EU DC12)
Specifications for "EU" type differ from standard models. Contact Omron for more details
Specifications
■ Coil Ratings
Rated voltage (V)
SPDT
SPST-NO
DC 5
Rated coil
current (mA)
80
Coil resistance
(Ω)
63
DC 9
44.4
202
DC 12
33.3
360
DC 24
16.7
1440
DC 5
40
125
DC 9
22.2
405
DC 12
16.7
720
DC 24
8.3
2880
Pick-up
voltage
Drop-out
voltage
Maximum
voltage
Power
consumption
(mW)
Percent of rated voltage
75% max
5% min
190% @ 23°C
400
200
Note: Rated current and coil resistance are measured at 23°C with a tolerance of ±10%.
PCB Relay
G5Q
163
■ Contact Ratings
Item
SPDT
SPST-NO
Rated load (resistive)
10 A at 125 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 30 VDC (NC)
10 A at 125 VAC
3 A at 250 VAC
5 A at 30 VDC
Contact material
Ag alloy
Rated carry current
10 A (NO)/3 A (NC)
Max. switching voltage
277 VAC, 30 VDC
Max. switching current
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
Max. switching capacity
1250 VA, 150 W (NO)
375 VA, 90 W (NC)
Min. permissible load
10 mA at 5 VDC (P level: λ60 = 0.1 × 10−6/operation)
■ Characteristics
Contact resistance (See note 2.)
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance (See note 3.)
1,000 mΩ min.
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
8 kV (1.2 × 50 μs) between coil an contacts
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 to 10 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Life expectancy (See Note 4)
Mechanical
10,000,000 operations (18,000 operations per hour)
Electrical
200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC, resistive load
100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC,
5 A (NO)/3 A (NC) at 30 VDC, resistive load
50,000 operations:
10 A at 125 VAC (900 operations per hour)
Ambient temperature
Operating &
storage
−40°C to 105°C (-40°F to 221°F) with no icing or condensation
Ambient humidity
Operating &
storage
5% to 85%
Note: 1.
2.
3.
4.
164
The data shown above are initial values.
The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC.
The electrical life data items shown are possible at 23°C
PCB Relay
G5Q
■ Approved Standard
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp = 40°C
Model
Coil ratings
Contact ratings
NO contacts
NC contacts
G5Q
5 to 24 VDC
10 A at 250 VAC (Resistive), 6,000 ops
10 A at 30 VDC (Resistive), 6,000 ops
4 A at 120VAC (Resistive), 10,000 ops.
3 A at 250 VAC (Resistive), 6,000 ops.
3 A at 30 VDC (Resistive), 6,000 ops.
EN 61810-1 (VDE Reg. No. 125314)
Model
Coil ratings
Contact ratings
G5Q
5, 9, 12, 24 VDC
10 A, 250 VAC cosφ=1 (NO)
5 A, 30 VDC L/R=0 ms (NO)
3 A, 30 VDC L/R=0 ms (NC)
Engineering Data
■ AMBIENT TEMPERATURE VS.
MAXIMUM VOLTAGE
■ AMBIENT TEMPERATURE VS.
RATED CARRY CURRENT
200
12
11
160
Rated carry current (A)
Maximum coil voltage (% of rated)
180
140
120
100
80
60
40
20
0
--40 --20 0
20 40 60 80 100 120
105
Ambient temperature (°C)
10
9
8
7
6
5
4
NO contact
3
2
NC contact
1
0
0
20 40 60 80 100 105 120
Ambient temperature (°C)
■ MAX. SWITCHING CAPACITY
12
11
AC resistive
load (NO)
Switching current (A)
10
9
8
DC resistive
load (NO)
7
6
AC resistive
load (NC)
5
4
3
2
DC resistive
load (NC)
1
0
1
10 30
250 277 1000
100
Switching voltage (V)
PCB Relay
G5Q
165
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G5Q-1A
G5Q-1A4
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
10.3 max.
(0.406)
20.3 max.
(0.799)
(1.18)
les
o
.h
Terminal Arrangement/
Internal Connections
(Bottom View)
ia
ur, -d
Fo ±0.1
1.3
(1.19)
1
2
3
7.62±0.1
15.8 max.
(0.622)
5
7.62±0.1
0.4
3.4
0.4 × 0.4
7.62
10.16
G5Q-1
G5Q-14
10.16±0.1
1
0.27
max.
7.62
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
10.3 max.
(0.406)
20.3 max.
(0.799)
(1.18)
(1.19)
15.8 max.
(0.622)
1
5
3.4
0.4 × 0.4
2.54±0.1
1
0.27
max.
5.08±0.1
7.62
10.16
PCB Relay
Terminal Arrangement/
Internal Connections
(Bottom View)
2
3
7.62±0.1
0.4
166
o
.h
a
-di
e,
Fiv ±0.1
1.3
les
G5Q
5.08
2.54
10.16±0.1
4
MEMO
PCB Relay
G5Q
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1b
PCB Relay
09/11
G5Q
Specifications subject to change without notice
Printed in USA
Similar pages