Mean Well HRP-75-5 75w single output with pfc function Datasheet

HRP-75
75W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Protections: Over temperature (optional)
Cooling by free air convection
1U low profile 38mm
Built-in remote ON-OFF control
No load power consumption<0.5W
All using 105 long life electrolytic capacitors
5 years warranty
SPECIFICATION
MODEL
OUTPUT
HRP-75-3.3
HRP-75-5
HRP-75-7.5
HRP-75-12
HRP-75-15
HRP-75-24
HRP-75-36
HRP-75-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
15A
15A
10A
6.3A
5A
3.2A
2.1A
1.6A
CURRENT RANGE
0 ~ 15A
0 ~ 15A
0 ~ 10A
0 ~ 6.3A
0 ~ 5A
0 ~ 3.2A
0 ~ 2.1A
0 ~ 1.6A
RATED POWER
49.5W
75W
75W
75.6W
75W
76.8W
75.6W
76.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p
120mVp-p
150mVp-p
150mVp-p
200mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
4.7 ~ 5.8V
2.5%
7.1 ~ 9V
2.5%
11 ~ 13.8V
1.5%
14.2 ~ 18V
1.5%
21.6 ~ 28.8V
1.5%
32 ~ 39.6V
1.5%
45 ~ 55.2V
1.5%
VOLTAGE TOLERANCE Note.3
3.1 ~ 3.8V
2.5%
LINE REGULATION
1.0%
1.0%
1.0%
0.3%
0.3%
0.2%
0.2%
0.2%
LOAD REGULATION
2.0%
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1800ms, 25ms/230VAC
HOLD UP TIME (Typ.)
50ms/230VAC
VOLTAGE RANGE
Note.5 85 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
INPUT
POWER FACTOR (Typ.)
PF>0.9/230VAC
EFFICIENCY (Typ.)
77%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.2A/115VAC
35A/115VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
FUNCTION
1800ms, 25ms/115VAC at full load
20ms/115VAC at full load
120 ~ 370VDC
PF>0.95/115VAC at full load
82.5%
84%
87%
88%
88.5%
89%
89%
0.7A/230VAC
65A/230VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
41.4 ~ 48.6V 57.6 ~ 67.2V
3.96 ~ 4.62V
Protection type : Shut down o/p voltage, re-power on to recover
85
5 for 3.3V~15V; 80
5 for 24V~48V (TSW1 : detect on heatsink of power transistor) (optional)
OVER TEMPERATURE (OPTIONAL)
Protection type : Shut down o/p voltage , recovers automatically after temperature goes down
RC+ / RC-: 0 ~ 0.8V = power on ; 4 ~ 10V = power off
REMOTE CONTROL
-40 ~ +70 (Refer to "Derating Curve")
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024 , EN61000-6-2 , heavy industry level, criteria A
MTBF
394.8K hrs min.
DIMENSION
129*98*38mm (L*W*H)
0.47Kg; 30pcs/ 15Kg/ 0.97CUFT
PACKING
NOTE
I/P-O/P:3KVAC
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-75-SPEC 2011-07-05
HRP-75
75W Single Output with PFC Function
Mechanical Specification
Case No.903D
series
Unit:mm
31
3.5
7
122.5
9.5
1
2
3L
=5
98
4
M
85.5
2-
33
8.2
3
5
1 2
SVR1
CN100
3 .5
4.5
73.5
Terminal Pin No. Assignment
129
6.5
Mating Housing
Terminal
JST XHP
or equivalent
JST SXH-001T
or equivalent
3L
=5
32
38
3.5
3-M
18
Assignment
RCRC+
3.5
12 max.
Remote ON/OFF (CN100) : JST B-XH or equivalent
Pin No.
1
2
120
28.5
Assignment
DC OUTPUT -V
DC OUTPUT +V
9.5
Pin No.
4
5
18.5
Assignment
AC/L
AC/N
FG
9
Pin No.
1
2
3
77
Block Diagram
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
PFC
POWER
SWITCHING
O.T.P.
O.L.P.
RECTIFIERS
&
FILTER
DETECTION
CIRCUIT
FG
PFC
CONTROL
+V
-V
PWM
CONTROL
O.V.P.
RC+
REMOTE
CONTROL
Derating Curve
RC-
Output Derating VS Input Voltage
Ta = 25
100
100
90
80
80
230VAC
Input only
70
LOAD(%)
LOAD (%)
60
40
30
20
-40
-20
-40
-10
0
20
40
50
AMBIENT TEMPERATURE ( )
start up possible for 230VAC input
60
70
(HORIZONTAL)
60
50
40
85
100
125
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:HRP-75-SPEC 2011-07-05