RSG LEP100F-48 Ac-dc power supplies open frame/ enclosed type Datasheet

Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LEP100F
LEP 100
1
2
F
3
-24
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
LEP
*The EMI/EMC Filter is recommended
*to connect with several devices.
MODEL
DC OUTPUT
LEP100F-24
+24V 4.2(Peak 7)A
LEP100F-36
+36V 2.8(Peak 4.7)A
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *1 *6
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
is set at a lower value
Z :with ZT
LEP100F-48
+48V 2.1(Peak 3.5)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*2
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +50C *3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
DRIFT[mV]
*4
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT -RC
*5
INPUT-FG
OUTPUT-RC-FG
*5
OUTPUT-RC
*5
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEP100F-24
LEP100F-36
LEP100F-48
AC85 - 264 1f or DC 120 - 370
1.4typ (Io=100%)
0.7typ (Io=100%)
50/60 (47 - 63) or DC
81typ (Io=100%)
82typ (Io=100%)
83typ (Io=100%)
84typ (Io=100%)
85typ (Io=100%)
85typ (Io=100%)
0.98typ (Io=100%)
0.93typ (Io=100%)
15typ (Io=100%) (At cold start) (Ta=25 C)
30typ (Io=100%) (At cold start) (Ta=25 C)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+24
+36
+48
0 - 4.2 (Peak 7)
0 - 2.8 (Peak 4.7)
0 - 2.1 (Peak 3.5)
100.8 (Peak 168)
100.8 (Peak 169.2)
100.8 (Peak 168)
48max
48max
48max
76max
90max
150max
120max
120max
150max
160max
160max
300max
150max
150max
250max
180max
180max
350max
120max
150max
240max
145max
180max
300max
48max
48max
48max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.4 - 26.4
26.4 - 39.6
39.6 - 52.8
23.0 - 25.0
35.0 - 37.0
46.0 - 50.0
Works over 101% of peak current and recovers automatically
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *7
75X35X222mm [2.95X1.38X8.74 inches] (W XHXD) /380g max (without chassis and cover)
Convection
*1 Specification is changed at option, refer to Instruction Manual 6.
*2 Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
*3 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEP-2
*5
*6
*7
*
*
*
Applicable when remote control (optional) is added.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
LEP100F
External view
235-+0.5
Voltage adjust
4.5
85
[3.35]
42
[1.18]
[0.98]
20
30
[0.79]
CN3
[0.18]
8
[1.77]
+V
CN2
CN1
25-+0.5
4
5
Mounting
Hole
[0.18]
45-+0.5
CN2
1
(68)
-V
C119
[2.68]
75
[2.95]
65 -+ 0.5
[2.56]
CN1
5 FG
3 Input(N)
1 Input(L)
8
[0.31] 4-M4
[9.25]
2-º4.5
[1.65]
3-º3.5 [0.14]
Mounting
Hole
Name plate
LEP
Connector for Remote
ON/OFF (option)
[8.35]
[0.2]
222
[0.18]
8
[0.31]
4.5
CN3
20
[1.26]
CN4
CN3
252
[9.92]
235-+0.5
[9.25]
º4.5
2-M4
Mounting
Hole
[0.12](Lead)
3max
32
[8.74]
CN4
RC(-)
PCB t=1.6
46
º3.5-4.0 [0.14-0.16]
Mounting Hole
Connector for
-Z (option)
[1.81]
212 -+ 0.5
15
[6.93]
[0.79] [0.59]
(176)
5
[0.18]
5
[0.2]
CN4
RC(+)
+ COM -
[0.06]
PIN CONNECTION
I / O Connector Mating Connector
Terminal
Chain : SVH-21T-P1.1
CN1
B3P5-VH
VHR-5N
Loose: BVH-21T-P1.1
Chain : SVH-21T-P1.1
CN2
B8P-VH
VHR-8N
Loose: BVH-21T-P1.1
Chain : SXH-001T-P0.6
CN3
B2B-XH-A
XHP-2
(Option)
Loose: BXH-001T-P0.6
Chain : SXH-001T-P0.6
CN4
B3B-XH-A
XHP-3
(Option)
Loose: BXH-001T-P0.6
(Mfr: J.S.T.)
CN1
Pin No. Input
1
AC(L)
2
3
AC(N)
4
5
FG
CN2
Pin No.
Output
1, 2, 3, 4 -V
+V
5, 6, 7, 8
CN3 (Option)
Pin No. Remote ON/OFF
1
RC(+)
2
RC(-)
¶Weight: 380g max
(Without chassis and cover)
¶Tolerance: t1 [t0.04]
¶Dimensions in mm, [ ]=inches
¶PCB Material : CEM3
¶Chassis and cover is optional.
¶Mounting torque: 1.5N · m(16kgf · cm)max
CN4 (Option)
Pin No.
-Z
1
+
COM
2
3
¶Keep drawing current per pin below 5A(7A at peak load)for CN2
Performance data
¡RISE TIME & FALL TIME (LEP100F-24)
¡EFFICIENCY (LEP100F-24)
86
ACIN 100V Io=100%
EFFICIENCY
84
DC Output
AC Input
76
60
20ms/DIV
¡INPUT HARMONIC CURRENT (LEP100F-24)
Load factor100%
Load factor 50%
100
140
180
220
INPUT VOLTAGE
260
300
V
¡INPUT HARMONIC CURRENT (LEP100F-24)
10
10
HARMONIC CURRENT
Load factor
100%
Input voltage AC 100V
1
0.1
0.01
10
20
HARMONIC ORDER
30
Harmonic current standard class A
(at odd number)
A
Harmonic current standard class A
(at odd number)
A
HARMONIC CURRENT
80
78
100ms/DIV
0.001
0
82
40
1
Load factor
100%
Input voltage AC 230V
0.1
0.01
0.001
0
10
20
30
40
HARMONIC ORDER
LEP-3
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LEP150F
LEP 150
1
2
F
3
-24
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
LEP
*The EMI/EMC Filter is recommended
*to connect with several devices.
MODEL
DC OUTPUT
LEP150F-24
+24V 6.3(Peak 12)A
LEP150F-36
+36V 4.2(Peak 8)A
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *1 *6
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
is set at a lower value
Z :with ZT
LEP150F-48
+48V 3.2(Peak 6)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*2
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +45C *3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +45C *3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +45C
TEMPERATURE REGULATION[mV]
-10 to +45C
DRIFT[mV]
*4
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT -RC
*5
INPUT-FG
OUTPUT-RC-FG
*5
OUTPUT-RC
*5
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEP150F-24
LEP150F-36
LEP150F-48
AC85 - 264 1f or DC 120 - 370
2.0typ (Io=100%)
1.0typ (Io=100%)
50/60 (47 - 63) or DC
82typ (Io=100%)
83typ (Io=100%)
84typ (Io=100%)
85typ (Io=100%)
86typ (Io=100%)
87typ (Io=100%)
0.98typ (Io=100%)
0.93typ (Io=100%)
15typ (Io=100%) (At cold start) (Ta=25 C)
30typ (Io=100%) (At cold start) (Ta=25 C)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+24
+36
+48
0 - 6.3 (Peak 12)
0 - 4.2 (Peak 8)
0 - 3.2 (Peak 6)
151.2 (Peak 288)
151.2 (Peak 288)
153.6 (Peak 288)
48max
48max
48max
76max
90max
150max
120max
120max
150max
160max
160max
300max
150max
150max
250max
180max
180max
350max
120max
150max
240max
145max
180max
300max
48max
48max
48max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.4 - 26.4
26.4 - 39.6
39.6 - 52.8
23.0 - 25.0
35.0 - 37.0
46.0 - 50.0
Works over 101% of peak current and recovers automatically
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *7
85X40X222mm [3.35X1.57X8.74 inches] (W XHXD) /490g max (without chassis and cover)
Convection
*1 Specification is changed at option, refer to Instruction Manual 6.
*2 Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
*3 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEP-4
*5
*6
*7
*
*
*
Applicable when remote control (optional) is added.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
LEP150F
External view
235-+0.5
º3.5-4.0 [0.14-0.16]
Mounting Hole
Connector for
-Z (option)
95
252
235-+0.5
8
4.5
25
[1.46]
CN3
RC(-)
[2.01]
[0.31]
51
[9.25]
2-M4
Mounting
Hole
CN4
CN3
[9.92]
º4.5
[0.18]
[0.12](Lead)
[0.18]
4.5
CN4
[0.98] [0.59]
222
[8.74]
37
LEP
15
212 -+ 0.5
[8.35]
3max
[3.74]
47
[1.18]
[1.38]
20
[0.79]
30
55-+0.5
Connector for Remote
ON/OFF (option)
105 -+ 0.5
[4.13]
[0.18]
5
CN1
CN3
CN4
[0.2]
[2.16]
CN2
1
4
5
8
(68)
-V
[2.68]
[2.95]
85
[3.35]
75 -+0.5
CN2
C119
+V
5
4-M4
Mounting
Hole
[0.18]
CN1
[0.2]
[0.31]
2-º4.5
35-+0.5
(215)
[8.46]
5 FG
3 Input(N)
1 Input(L)
8
[9.25]
4-º3.5 [0.14]
Mounting
Hole
[1.85]
Voltage adjust
Name plate
RC(+)
+ COM -
PCB t=1.6
[0.06]
I / O Connector Mating Connector
Terminal
Chain : SVH-21T-P1.1
CN1
B3P5-VH
VHR-5N
Loose: BVH-21T-P1.1
Chain : SVH-21T-P1.1
CN2
B8P-VH
VHR-8N
Loose: BVH-21T-P1.1
Chain : SXH-001T-P0.6
CN3
XHP-2
(Option) B2B-XH-A
Loose: BXH-001T-P0.6
Chain : SXH-001T-P0.6
CN4
B3B-XH-A
XHP-3
(Option)
Loose: BXH-001T-P0.6
(Mfr: J.S.T.)
PIN CONNECTION
CN1
Pin No. Input
1
AC(L)
2
3
AC(N)
4
5
FG
CN2
Pin No.
Output
1, 2, 3, 4 -V
5, 6, 7, 8
+V
CN3 (Option)
Pin No. Remote ON/OFF
1
RC(+)
2
RC(-)
¶Weight: 490g max
(Without chassis and cover)
¶Tolerance: t1 [t0.04]
¶Dimensions in mm, [ ]=inches
¶PCB Material : CEM3
¶Chassis and cover is optional.
¶Mounting torque: 1.5N · m(16kgf · cm)max
CN4 (Option)
Pin No.
-Z
1
+
COM
2
3
¶Keep drawing current per pin below 5A(7A at peak load)for CN2
Performance data
¡RISE TIME & FALL TIME (LEP150F-24)
¡EFFICIENCY (LEP150F-24)
88
86
ACIN 100V Io=100%
EFFICIENCY
84
DC Output
82
80
AC Input
78
100ms/DIV
76
60
20ms/DIV
¡INPUT HARMONIC CURRENT (LEP150F-24)
140
180
220
260
300
V
¡INPUT HARMONIC CURRENT (LEP150F-24)
10
HARMONIC CURRENT
Load factor
100%
Input voltage AC 100V
1
0.1
0.01
10
20
HARMONIC ORDER
30
Harmonic current standard class A
(at odd number)
A
Harmonic current standard class A
(at odd number)
A
HARMONIC CURRENT
100
INPUT VOLTAGE
10
0.001
0
Load factor100%
Load factor 50%
40
1
Load factor
100%
Input voltage AC 230V
0.1
0.01
0.001
0
10
20
30
40
HARMONIC ORDER
LEP-5
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LEP240F
LEP 240
1
2
F
3
-24
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
LEP
*The EMI/EMC Filter is recommended
*to connect with several devices.
MODEL
DC OUTPUT
LEP240F-24
+24V 10(Peak 20)A
LEP240F-36
+36V 6.7(Peak 13.4)A
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *1 *6
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
is set at a lower value
Z :with ZT
LEP240F-48
+48V 5(Peak 10)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*2
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +40C *3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +40C *3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +40C
TEMPERATURE REGULATION[mV]
-10 to +40C
DRIFT[mV]
*4
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT -RC
*5
INPUT-FG
OUTPUT-RC-FG
*5
OUTPUT-RC
*5
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEP240F-24
LEP240F-36
LEP240F-48
AC85 - 264 1f or DC 120 - 370
3.3typ (Io=100%)
1.7typ (Io=100%)
50/60 (47 - 63) or DC
83typ (Io=100%)
84typ (Io=100%)
84typ (Io=100%)
86typ (Io=100%)
87typ (Io=100%)
87typ (Io=100%)
0.98typ (Io=100%)
0.93typ (Io=100%)
15typ (Io=100%) (More than 3sec.to re-start)
30typ (Io=100%) (More than 3sec.to re-start)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+24
+36
+48
0 - 10 (Peak 20)
0 - 6.7 (Peak 13.4)
0 - 5 (Peak 10)
240.0 (Peak 480)
241.2 (Peak 482.4)
240.0 (Peak 480)
48max
48max
48max
76max
90max
150max
120max
120max
150max
160max
160max
300max
150max
150max
250max
180max
180max
350max
120max
150max
240max
145max
180max
300max
48max
48max
48max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.4 - 26.4
26.4 - 39.6
39.6 - 52.8
23.0 - 25.0
35.0 - 37.0
46.0 - 50.0
Works over 101% of peak current and recovers automatically
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *7
95X45X222mm [3.74X1.77X8.74 inches] (WXHXD) /690g max (without chassis and cover)
Convection
*1 Specification is changed at option, refer to Instruction Manual 6.
*2 Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
*3 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEP-6
*5
*6
*7
*
*
*
Applicable when remote control (optional) is added.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
LEP240F
External view
52
[1.3]
[1.77]
23
33
108
CN2
[4.25]
CN1
4.5
8
[0.18]
65-+0.5
+V
4-M4
Mounting
Hole
1
4
5
[2.56]
-V
(66)
CN2
[2.6]
85-+0.5
C119
[3.35]
95
[3.74]
CN1
5 FG
3 Input(N)
1 Input(L)
8
[0.31]
[9.25]
45-+0.5
[8.39]
[0.91]
2-º4.5
[0.18]
4-º3.5 [0.14]
Mounting
Hole
(213)
[2.05]
235-+0.5
Voltage adjust
Name plate
LEP
CN3
Connector for Remote
ON/OFF (option)
CN3
[0.12](Lead)
3max
RC(-)
I / O Connector Mating Connector
Terminal
Chain : SVH-21T-P1.1
CN1
B3P5-VH
VHR-5N
Loose: BVH-21T-P1.1
Chain : SVH-21T-P1.1
CN2
B8P-VH
VHR-8N
Loose: BVH-21T-P1.1
Chain : SXH-001T-P0.6
CN3
XHP-2
(Option) B2B-XH-A
Loose: BXH-001T-P0.6
Chain : SXH-001T-P0.6
CN4
XHP-3
(Option) B3B-XH-A
Loose: BXH-001T-P0.6
(Mfr: J.S.T.)
RC(+)
+ COM -
PCB t=1.6
[0.06]
[2.28]
[0.31]
[0.59]
CN4
8
[9.25]
58
[1.65]
[8.74]
252
[9.92]
235-+0.5
º4.5
[0.18]
2-M4
Mounting
Hole
[1.18]
Connector for
-Z (option)
222
CN3
15
[8.35]
42
CN4
º3.5-4.0 [0.14-0.16]
Mounting Hole
212 -+ 0.5
4.5
[4.88]
[0.18]
124 -+ 0.5
5
[0.2]
30
[0.2]
5
CN4
PIN CONNECTION
CN1
Pin No. Input
1
AC(L)
2
3
AC(N)
4
5
FG
CN2
Pin No.
Output
1, 2, 3, 4 -V
5, 6, 7, 8
+V
CN3 (Option)
Pin No. Remote ON/OFF
1
RC(+)
2
RC(-)
CN4 (Option)
Pin No.
-Z
1
+
COM
2
3
¶Weight: 690g max
(Without chassis and cover)
¶Tolerance: t1 [t0.04]
¶Dimensions in mm, [ ]=inches
¶PCB Material : CEM3
¶Chassis and cover is optional.
¶Mounting torque: 1.5N · m(16kgf · cm)max
¶Keep drawing current per pin below 5A(7A at peak load)for CN2
Performance data
¡RISE TIME & FALL TIME (LEP240F-24)
¡EFFICIENCY (LEP240F-24)
88
ACIN 100V Io=100%
EFFICIENCY
86
DC Output
AC Input
78
60
20ms/DIV
¡INPUT HARMONIC CURRENT (LEP240F-24)
Load factor100%
Load factor 50%
160
110
210
INPUT VOLTAGE
260
310
V
¡INPUT HARMONIC CURRENT (LEP240F-24)
10
10
HARMONIC CURRENT
Load factor
100%
Input voltage AC 100V
1
0.1
0.01
10
20
HARMONIC ORDER
30
Harmonic current standard class A
(at odd number)
A
Harmonic current standard class A
(at odd number)
A
HARMONIC CURRENT
82
80
100ms/DIV
0.001
0
84
40
1
Load factor
100%
Input voltage AC 230V
0.1
0.01
0.001
0
10
20
30
40
HARMONIC ORDER
LEP-7