POWERDYNAMICS HGN-341 Iec 60320 inlet socket with switch, voltage select and a fuse holder, snap-in mount Datasheet

HGN-341 IEC 60320 INLET SOCKET WITH SWITCH, VOLTAGE SELECT AND A
FUSE HOLDER, SNAP-IN MOUNT
MECHANICAL DIMENSIONS (Unit: mm)
57.0
240
220
110
120
40.0
A+0.2
0.8 TYP.
36.5
FEATURES
The HGN-341 power entry module features an IEC
Connector, 2-pole on/off switch, a fuse holder that accepts
both European 5 x 20mm or N. American 1/4” x 1 1/4”
(3AG) fuse, and a voltage selector with four different voltages
(110V, 120V, 220V, 240V). The voltage selector is
designed to provide a simple means to change transformer
primary connections.
6.3 TYP.
These filters are also available for Medical equipment
with low leakage current to comply with UL 544 & UL2601.
APPLICATIONS
55.0
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 3A, 4A, 6A,
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA, max
@ 250VAC 50Hz: 2µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
* Medical application
3.00
54.0
54.5+0.2
4x R1.5
37.0+0.2
RECOMMENDED
PANEL CUTOUT
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
66
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
HGN-341 Series Example & Ordering Code
HGN-341 - 1
=
=
=
=
=
CURRENT RATING (A):
SCHEMATIC:
M - F1 - 150
1
2
3
4
6
STANDARD TYPE
=
WITHOUT C(Y); C(X) ONLY
=M
BLANK
TERMINAL:
= F1
QUICK CONNECT (6.3 x 0.8)
PANEL THICKNESS*:
0.06 (1.5MM)
0.062 (1.6MM)
0.08 (2.0MM)
= 150
= 160
= 200
* More panel thickness options are available upon request
Attenuation Tables & Schematics
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
57
49
41
35
30
50
49
49
40
34
50
50
54
50
45
64
65
60
65
55
29
30
34
32
35
9
10
9
9
9
14
15
14
14
12
14
16
19
20
19
45
40
33
20
19
65
60
54
45
40
70
70
70
70
70
60
60
60
60
60
29
30
33
32
35
E
P
a
2200pF
b c
E'
2200pF
L mH
d
e
1
2
3
4
5
6
110V
110V
LOAD
40
35
30
21
19
F
30
25
20
14
10
0.033
19
11
5
2
2
1M
1A
2A
3A
4A
6A
FUSE
L mH
N
0.033 F
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
Current
Rating .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30
LINE
L
Value
18V
FUSE
Medical Applications
Insertion loss in dB (50 Ohm circuit)
41
38
33
23
19
51
40
38
30
27
48
42
38
32
29
37
36
30
32
29
31
30
23
30
29
22
21
18
22
25
9
9
9
9
9
11
11
15
13
18
15
11
14
19
21
50
42
38
19
19
67 82
67 82
55 82
44 82
47 84
71
75
76
79
82
37
38
35
40
50
E
P
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
L mH
E'
b c
d
e
1
2
3
4
5
6
110V
110V
LOAD
32
30
28
18
13
a
0.033 F
22
18
18
10
8
0.033 F
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
FUSE
L mH
N
1M
1A
2A
3A
4A
6A
L
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
Value .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30
LINE
Current
Rating
18V
FUSE