M58WR016QT M58WR016QB M58WR032QT M58WR032QB 16 Mbit and 32 Mbit (x16, Multiple Bank, Burst) 1.8V supply Flash memories Feature summary ■ ■ Supply voltage – VDD = 1.7V to 2V for Program, Erase and Read – VDDQ = 1.7V to 2.24V for I/O Buffers – VPP = 12V for fast Program (optional) FBGA Synchronous / Asynchronous Read – Synchronous Burst Read mode: 66MHz – Asynchronous/ Synchronous Page Read mode – Random access: 60ns, 70ns, 80ns ■ Synchronous Burst Read Suspend ■ Programming time – 8µs by Word typical for Fast Factory Program – Double/Quadruple Word Program option – Enhanced Factory Program options ■ Memory blocks – Multiple Bank memory array: 4 Mbit Banks – Parameter blocks (top or bottom location) ■ Dual operations – Program Erase in one bank while Read in others – No delay between Read and Write operations ■ Block locking – All blocks locked at Power up – Any combination of blocks can be locked – WP for Block Lock-Down ■ Security – 128 bit user programmable OTP cells – 64 bit unique device number ■ Common Flash Interface (CFI) ■ 100,000 program/erase cycles per block November 2007 VFBGA56 (ZB) 7.7 x 9 mm ■ Electronic signature – Manufacturer Code: 20h – Device Codes: M58WR016QT (Top): 8812h. M58WR016QB (Bottom): 8813h M58WR032QT (Top): 8814h M58WR032QB (Bottom): 8815h ■ ECOPACK® package available Rev 2 1/110 www.numonyx.com 1 Contents M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Contents 1 Summary description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3 2.1 Address Inputs (A0-Amax) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.2 Data Input/Output (DQ0-DQ15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.3 Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.4 Output Enable (G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.5 Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.6 Write Protect (WP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.7 Reset (RP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.8 Latch Enable (L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.9 Clock (K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.10 Wait (WAIT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.11 VDD supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.12 VDDQ supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.13 VPP Program supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.14 VSS Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.15 VSSQ Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.1 Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.2 Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.3 Address Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.4 Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.5 Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.6 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4 Command interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5 Command interface - standard commands . . . . . . . . . . . . . . . . . . . . . 20 2/110 5.1 Read Array command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.2 Read Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 6 5.3 Read Electronic Signature command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.4 Read CFI Query command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.5 Clear Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.6 Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.7 Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.8 Program/Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.9 Program/Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.10 Protection Register Program command . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5.11 Set Configuration Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5.12 Block Lock command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.13 Block Unlock command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.14 Block Lock-Down command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Command interface - factory program commands . . . . . . . . . . . . . . . 28 6.1 Bank Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6.2 Double Word Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6.3 Quadruple Word Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 6.4 Enhanced Factory Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 6.5 7 Contents 6.4.1 Setup Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 6.4.2 Program Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 6.4.3 Verify Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 6.4.4 Exit Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Quadruple Enhanced Factory Program command . . . . . . . . . . . . . . . . . . 32 6.5.1 Setup Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.5.2 Load Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.5.3 Program and Verify Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.5.4 Exit Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 7.0.1 Program/Erase Controller Status Bit (SR7) . . . . . . . . . . . . . . . . . . . . . . 35 7.0.2 Erase Suspend Status Bit (SR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 7.0.3 Erase Status Bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 7.0.4 Program Status Bit (SR4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 7.0.5 VPP Status Bit (SR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 7.0.6 Program Suspend Status Bit (SR2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 3/110 Contents 8 9 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 7.0.7 Block Protection Status Bit (SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 7.0.8 Bank Write/Multiple Word Program Status Bit (SR0) . . . . . . . . . . . . . . . 37 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 8.1 Read Select Bit (CR15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 8.2 X-Latency Bits (CR13-CR11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 8.3 Wait Polarity Bit (CR10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8.4 Data Output Configuration Bit (CR9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8.5 Wait Configuration Bit (CR8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8.6 Burst Type Bit (CR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8.7 Valid Clock Edge Bit (CR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8.8 Wrap Burst Bit (CR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8.9 Burst length Bits (CR2-CR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Read modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 9.1 Asynchronous Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 9.2 Synchronous Burst Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 9.2.1 9.3 Synchronous Burst Read Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Single Synchronous Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 10 Dual operations and Multiple Bank architecture . . . . . . . . . . . . . . . . . 49 11 Block locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 11.1 Reading a Block’s lock status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 11.2 Locked state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 11.3 Unlocked state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 11.4 Lock-Down state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11.5 Locking operations during Erase Suspend . . . . . . . . . . . . . . . . . . . . . . . . 52 12 Program and erase times and endurance cycles . . . . . . . . . . . . . . . . . 54 13 Maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 14 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 15 Package mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 4/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 16 Contents Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Appendix A Block address tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Appendix B Common Flash Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Appendix C Flowcharts and pseudo codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 C.1 Enhanced Factory Program pseudo code. . . . . . . . . . . . . . . . . . . . . . . . 102 C.2 Quadruple Enhanced Factory Program Pseudo Code . . . . . . . . . . . . . . 104 Appendix D Command interface state tables. . . . . . . . . . . . . . . . . . . . . . . . . . . 105 17 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 5/110 List of tables M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Table 27. Table 28. Table 29. Table 30. Table 31. Table 32. Table 33. Table 34. Table 35. Table 36. Table 37. Table 38. Table 39. Table 40. Table 41. Table 42. Table 43. Table 44. Table 45. Table 46. Table 47. 6/110 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 M58WR016QT/B Bank architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 M58WR032QT/B Bank architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Command codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Standard commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Electronic signature codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Factory Program commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Status Register bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Configuration Register bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Burst type definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Dual operations allowed in other banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Dual operations allowed in same bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Lock status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Program/Erase times and endurance cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Operating and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 DC characteristics - currents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 DC characteristics - voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Asynchronous Read AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Synchronous Read AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Write AC characteristics, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Write AC characteristics, Chip Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Reset and Power-up AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 VFBGA56 - 7.7x9mm, 8x7 ball array, 0.75mm pitch, package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Daisy chain ordering scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Top boot block addresses, M58WR016QT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Bottom boot block addresses, M58WR016QB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Top boot block addresses, M58WR032QT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Bottom boot block addresses, M58WR032QB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Query structure overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 CFI Query identification string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 CFI query system interface information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Device geometry definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Primary algorithm-specific extended query table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Protection Register Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Burst Read information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Bank and erase block region information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Bank and erase block region 1 information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Bank and erase block region 2 information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Command interface states - modify table, next state . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Command interface states - modify table, next output state. . . . . . . . . . . . . . . . . . . . . . . 106 Command interface states - lock table, next state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Command interface states - lock table, next output state . . . . . . . . . . . . . . . . . . . . . . . . . 108 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Figure 26. Figure 27. Figure 28. Figure 29. Logic Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 VFBGA Connections (Top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 M58WR016QT/B memory map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 M58WR032QT/B memory map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Protection Register Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 X-Latency and data output configuration example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Wait configuration example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 AC measurement load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Asynchronous Random Access Read AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Asynchronous Page Read AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Synchronous Burst Read AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Single Synchronous Read AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Synchronous Burst Read Suspend AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Clock input AC waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Write AC waveforms, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Write AC waveforms, Chip Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Reset and Power-up AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 VFBGA56 - 7.7x9mm, 8x7 ball array, 0.75mm pitch, Bottom View Package Outline . . . . . 73 Program flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Double Word Program flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Quadruple Word Program flowchart and pseudo code. . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Program Suspend & Resume flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . 96 Block Erase flowchart and pseudo code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Erase Suspend & Resume flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Locking operations flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Protection Register Program flowchart and pseudo code . . . . . . . . . . . . . . . . . . . . . . . . 100 Enhanced Factory Program flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Quadruple Enhanced Factory Program flowchart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 7/110 Summary description 1 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Summary description The M58WR016QT/B and M58WR032QT/B are 16 Mbit (1 Mbit x16) and 32 Mbit (2 Mbit x16) non-volatile Flash memories, respectively. They will be referred to as M58WRxxxQT/B throughout the document unless otherwise specified. The M58WRxxxQT/B may be erased electrically at block level and programmed in-system on a Word-by-Word basis using a 1.7V to 2V VDD supply for the circuitry and a 1.7V to 2.24V VDDQ supply for the Input/Output pins. An optional 12V VPP power supply is provided to speed up customer programming. The VPP pin can also be used as a control pin to provide absolute protection against program or erase. The device features an asymmetrical block architecture. ● M58WR016QT/B has an array of 39 blocks, and is divided into 4 Mbit banks. There are 3 banks each containing 8 main blocks of 32 KWords, and one parameter bank containing 8 parameter blocks of 4 KWords and 7 main blocks of 32 KWords. ● M58WR032QT/B has an array of 71 blocks, and is divided into 4 Mbit banks. There are 7 banks each containing 8 main blocks of 32 KWords, and one parameter bank containing 8 parameter blocks of 4 KWords and 7 main blocks of 32 KWords. The Multiple Bank Architecture allows Dual Operations, while programming or erasing in one bank, Read operations are possible in other banks. Only one bank at a time is allowed to be in Program or Erase mode. It is possible to perform burst reads that cross bank boundaries. The bank architectures are summarized in Table 2 and Table 3, and the memory maps are shown in Figure 3 and Figure 4. The Parameter Blocks are located at the top of the memory address space for the M58WR016QT and M58WR032QT, and at the bottom for the M58WR016QB and M58WR032QB. Each block can be erased separately. Erase can be suspended, in order to perform program in any other block, and then resumed. Program can be suspended to read data in any other block and then resumed. Each block can be programmed and erased over 100,000 cycles using the supply voltage VDD. There are two Enhanced Factory programming commands available to speed up programming. Program and Erase commands are written to the Command Interface of the memory. An internal Program/Erase Controller takes care of the timings necessary for program and erase operations. The end of a program or erase operation can be detected and any error conditions identified in the Status Register. The command set required to control the memory is consistent with JEDEC standards. The device supports synchronous burst read and asynchronous read from all blocks of the memory array; at power-up the device is configured for asynchronous read. In synchronous burst mode, data is output on each clock cycle at frequencies of up to 66MHz. The synchronous burst read operation can be suspended and resumed. The device features an Automatic Standby mode. When the bus is inactive during Asynchronous Read operations, the device automatically switches to the Automatic Standby mode. In this condition the power consumption is reduced to the standby value IDD4 and the outputs are still driven. The M58WRxxxQT/B features an instant, individual block locking scheme that allows any block to be locked or unlocked with no latency, enabling instant code and data protection. All blocks have three levels of protection. They can be locked and locked-down individually 8/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Summary description preventing any accidental programming or erasure. There is an additional hardware protection against program and erase. When VPP ≤VPPLK all blocks are protected against program or erase. All blocks are locked at Power- Up. The device includes a Protection Register to increase the protection of a system’s design. The Protection Register is divided into two segments: a 64 bit segment containing a unique device number written by Numonyx, and a 128 bit segment One-Time-Programmable (OTP) by the user. The user programmable segment can be permanently protected. Figure 5 shows the Protection Register Memory Map. The memory is offered in a VFBGA56, 7.7 x 9mm, 8x7 active ball array, 0.75 mm pitch package and is supplied with all the bits erased (set to ’1’). In order to meet environmental requirements, Numonyx offers these devices in ECOPACK® packages. These packages have a Lead-free second level interconnect. The category of second Level Interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. 9/110 Summary description Figure 1. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Logic Diagram VDD VDDQ VPP 16 A0-Amax(1) DQ0-DQ15 W E G RP M58WR016QT M58WR016QB M58WR032QT M58WR032QB WAIT WP L K VSS VSSQ AI10170 1. Amax is equal to A19 for the M58WR016QT/B and to A20 for the M58WR032QT/B. Table 1. Signal names A0-Amax(1) Address Inputs DQ0-DQ15 Data Input/Outputs, Command Inputs E Chip Enable G Output Enable W Write Enable RP Reset WP Write Protect K Clock L Latch Enable WAIT Wait VDD Supply Voltage VDDQ Supply Voltage for Input/Output Buffers VPP Optional Supply Voltage for Fast Program & Erase VSS Ground VSSQ Ground Input/Output Supply NC Not Connected Internally 1. Amax is equal to A19 for the M58WR016QT/B and to A20 for the M58WR032QT/B. 10/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 2. Summary description VFBGA Connections (Top view through package) 1 2 3 4 5 6 7 8 A A11 A8 VSS VDD VPP A18 A6 A4 B A12 A9 A20 K RP A17 A5 A3 C A13 A10 NC L W A19 A7 A2 D A15 A14 WAIT A16 DQ12 WP NC A1 E VDDQ DQ15 DQ6 DQ4 DQ2 DQ1 E A0 F VSS DQ14 DQ13 DQ11 DQ10 DQ9 DQ0 G G DQ7 VSSQ DQ5 VDD DQ3 VDDQ DQ8 VSSQ AI09301 1. Ball B3 is A20 in the M58WR032QT/B and it is Not Connected internally (NC) in the M58WR016QT/B. Table 2. M58WR016QT/B Bank architecture Number Bank Size Parameter Blocks Main Blocks Parameter Bank 4 Mbits 8 blocks of 4 KWords 7 blocks of 32 KWords Bank 1 4 Mbits - 8 blocks of 32 KWords Bank 2 4 Mbits - 8 blocks of 32 KWords Bank 3 4 Mbits - 8 blocks of 32 KWords 11/110 Summary description Table 3. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB M58WR032QT/B Bank architecture Parameter Bank 4 Mbits 8 blocks of 4 KWords 7 blocks of 32 KWords Bank 1 4 Mbits - 8 blocks of 32 KWords Bank 2 4 Mbits - 8 blocks of 32 KWords Bank 3 4 Mbits - 8 blocks of 32 KWords ---- Main Blocks ---- Parameter Blocks ---- Bank Size ---- Number Bank 6 4 Mbits - 8 blocks of 32 KWords Bank 7 4 Mbits - 8 blocks of 32 KWords Figure 3. M58WR016QT/B memory map M58WR016QB - Bottom Boot Block Address lines A0-A19 M58WR016QT - Top Boot Block Address lines A0-A19 00000h 07FFFh 8 Main Blocks Bank 3 38000h 3FFFFh 40000h 47FFFh 32 KWord 8 Main Blocks 32 KWord 8 Main Blocks Parameter Bank F0000h F7FFFh F8000h F8FFFh FF000h FFFFFh 78000h 7FFFFh 80000h 87FFFh 32 KWord 8 Parameter Blocks 4KWord 32 KWord 7 Main Blocks 32 KWord 32 KWord 8 Main Blocks 32 KWord 32 KWord 8 Main Blocks Bank 2 32 KWord 4 KWord 8 Parameter Blocks Bank 3 4 KWord 4 KWord Bank 1 32 KWord 7 Main Blocks 07000h 07FFFh 08000h 0FFFFh 38000h 3FFFFh 40000h 47FFFh 32 KWord Bank 1 B8000h BFFFFh C0000h C7FFFh Parameter Bank 32 KWord Bank 2 78000h 7FFFFh 80000h 87FFFh 00000h 00FFFh 32 KWord B8000h BFFFFh C0000h C7FFFh F8000h FFFFFh 32 KWord 32 KWord 8 Main Blocks 32 KWord AI10171 12/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 4. M58WR032QT/B memory map M58WR032QB - Bottom Boot Block Address lines A0-A20 M58WR032QT - Top Boot Block Address lines A0-A20 000000h 007FFFh 32 KWord 038000h 03FFFFh 32 KWord 100000h 107FFFh 8 Main Blocks 1B8000h 1BFFFFh 1C0000h 1C7FFFh 1F0000h 1F7FFFh 1F8000h 1F8FFFh 1FF000h 1FFFFFh 078000h 07FFFFh 080000h 087FFFh 0B8000h 0BFFFFh 0C0000h 0C7FFFh 32 KWord 8 Main Blocks 8 Parameter Blocks 4KWord 32 KWord 7 Main Blocks 32 KWord 32 KWord 8 Main Blocks 32 KWord 32 KWord 8 Main Blocks Bank 2 32 KWord Bank 1 4 KWord Bank 1 32 KWord 8 Main Blocks 007000h 007FFFh 008000h 00FFFFh 038000h 03FFFFh 040000h 047FFFh 32 KWord Bank 2 178000h 17FFFFh 180000h 187FFFh Parameter Bank 32 KWord Bank 3 138000h 13FFFFh 140000h 147FFFh 000000h 000FFFh 8 Main Blocks Bank 7 Parameter Bank Summary description 32 KWord 32 KWord 8 Main Blocks Bank 3 32 KWord 0F8000h 0FFFFFh 32 KWord 1C0000h 1C7FFFh 32 KWord 1F8000h 1FFFFFh 32 KWord 32 KWord 7 Main Blocks 32 KWord 4 KWord 8 Parameter Blocks Bank 7 4 KWord 8 Main Blocks AI10172 13/110 Signal descriptions 2 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Signal descriptions See Figure 1: Logic Diagram and Table 1: Signal names, for a brief overview of the signals connected to this device. 2.1 Address Inputs (A0-Amax) Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. The Address Inputs select the cells in the memory array to access during Bus Read operations. During Bus Write operations they control the commands sent to the Command Interface of the internal state machine. 2.2 Data Input/Output (DQ0-DQ15) The Data I/O outputs the data stored at the selected address during a Bus Read operation or inputs a command or the data to be programmed during a Bus Write operation. 2.3 Chip Enable (E) The Chip Enable input activates the memory control logic, input buffers, decoders and sense amplifiers. When Chip Enable is at VILand Reset is at VIH the device is in active mode. When Chip Enable is at VIH the memory is deselected, the outputs are high impedance and the power consumption is reduced to the stand-by level. 2.4 Output Enable (G) The Output Enable controls data outputs during the Bus Read operation of the memory. 2.5 Write Enable (W) The Write Enable controls the Bus Write operation of the memory’s Command Interface. The data and address inputs are latched on the rising edge of Chip Enable or Write Enable whichever occurs first. 2.6 Write Protect (WP) Write Protect is an input that gives an additional hardware protection for each block. When Write Protect is at VIL, the Lock-Down is enabled and the protection status of the LockedDown blocks cannot be changed. When Write Protect is at VIH, the Lock-Down is disabled and the Locked-Down blocks can be locked or unlocked. (refer to Table 14: Lock status). 14/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 2.7 Signal descriptions Reset (RP) The Reset input provides a hardware reset of the memory. When Reset is at VIL, the memory is in reset mode: the outputs are high impedance and the current consumption is reduced to the Reset Supply Current IDD2. Refer to Table 19: DC characteristics - currents for the value of IDD2. After Reset all blocks are in the Locked state and the Configuration Register is reset. When Reset is at VIH, the device is in normal operation. Exiting reset mode the device enters asynchronous read mode, but a negative transition of Chip Enable or Latch Enable is required to ensure valid data outputs. The Reset pin can be interfaced with 3V logic without any additional circuitry. It can be tied to VRPH (refer to Table 20: DC characteristics - voltages). 2.8 Latch Enable (L) Latch Enable latches the address bits on its rising edge. The address latch is transparent when Latch Enable is at VIL and it is inhibited when Latch Enable is at VIH. Latch Enable can be kept Low (also at board level) when the Latch Enable function is not required or supported. 2.9 Clock (K) The clock input synchronizes the memory to the microcontroller during synchronous read operations; the address is latched on a Clock edge (rising or falling, according to the configuration settings) when Latch Enable is at VIL. Clock is don't care during asynchronous read and in write operations. 2.10 Wait (WAIT) Wait is an output signal used during synchronous read to indicate whether the data on the output bus are valid. This output is high impedance when Chip Enable is at VIH or Reset is at VIL. It can be configured to be active during the wait cycle or one clock cycle in advance. The WAIT signal is not gated by Output Enable. 2.11 VDD supply voltage VDD provides the power supply to the internal core of the memory device. It is the main power supply for all operations (Read, Program and Erase). 2.12 VDDQ supply voltage VDDQ provides the power supply to the I/O pins and enables all Outputs to be powered independently from VDD. VDDQ can be tied to VDD or can use a separate supply. 15/110 Signal descriptions 2.13 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB VPP Program supply voltage VPP is a power supply pin. The Supply Voltage VDD and the Program Supply Voltage VPP can be applied in any order. The pin can also be used as a control input. The two functions are selected by the voltage range applied to the pin. If VPP is kept in a low voltage range (0V to VDDQ) VPP is seen as a control input. In this case a voltage lower than VPPLK gives an absolute protection against program or erase, while VPP in the VPP1 range enables these functions (see Tables 19 and 20, DC Characteristics for the relevant values). VPP is only sampled at the beginning of a program or erase; a change in its value after the operation has started does not have any effect and program or erase operations continue. If VPP is in the range of VPPH it acts as a power supply pin. In this condition VPP must be stable until the Program/Erase algorithm is completed. 2.14 VSS Ground VSS ground is the reference for the core supply. It must be connected to the system ground. 2.15 VSSQ Ground VSSQ ground is the reference for the input/output circuitry driven by VDDQ. VSSQ must be connected to VSS. Note: 16/110 Each device in a system should have VDD, VDDQ and VPP decoupled with a 0.1µF ceramic capacitor close to the pin (high frequency, inherently low inductance capacitors should be as close as possible to the package). See Figure 9: AC measurement load circuit. The PCB track widths should be sufficient to carry the required VPP program and erase currents. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 3 Bus operations Bus operations There are six standard bus operations that control the device. These are Bus Read, Bus Write, Address Latch, Output Disable, Standby and Reset. See Table 4: Bus operations, for a summary. Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect Bus Write operations. 3.1 Bus Read Bus Read operations are used to output the contents of the Memory Array, the Electronic Signature, the Status Register and the Common Flash Interface. Both Chip Enable and Output Enable must be at VIL in order to perform a read operation. The Chip Enable input should be used to enable the device. Output Enable should be used to gate data onto the output. The data read depends on the previous command written to the memory (see Command Interface section). See Figures 10, 11, 12 and 13 Read AC Waveforms, and Tables 21 and 22 Read AC Characteristics, for details of when the output becomes valid. 3.2 Bus Write Bus Write operations write Commands to the memory or latch Input Data to be programmed. A bus write operation is initiated when Chip Enable and Write Enable are at VIL with Output Enable at VIH. Commands, Input Data and Addresses are latched on the rising edge of Write Enable or Chip Enable, whichever occurs first. The addresses can also be latched prior to the write operation by toggling Latch Enable. In this case the Latch Enable should be tied to VIH during the bus write operation. See Figures 16 and 17, Write AC Waveforms, and Tables 23 and 24, Write AC Characteristics, for details of the timing requirements. 3.3 Address Latch Address latch operations input valid addresses. Both Chip enable and Latch Enable must be at VIL during address latch operations. The addresses are latched on the rising edge of Latch Enable. 3.4 Output Disable The outputs are high impedance when the Output Enable is at VIH. 17/110 Bus operations 3.5 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Standby Standby disables most of the internal circuitry allowing a substantial reduction of the current consumption. The memory is in stand-by when Chip Enable and Reset are at VIH. The power consumption is reduced to the stand-by level and the outputs are set to high impedance, independently from the Output Enable or Write Enable inputs. If Chip Enable switches to VIH during a program or erase operation, the device enters Standby mode when finished. 3.6 Reset During Reset mode the memory is deselected and the outputs are high impedance. The memory is in Reset mode when Reset is at VIL. The power consumption is reduced to the Standby level, independently from the Chip Enable, Output Enable or Write Enable inputs. If Reset is pulled to VSS during a Program or Erase, this operation is aborted and the memory content is no longer valid. Table 4. Bus operations(1) Operation Bus Read WAIT(2) E G W L RP VIL VIL VIH VIL(3) VIH Data Output VIH Data Input Bus Write VIL VIH VIL VIL(3) Address Latch VIL X VIH VIL VIH Data Output or Hi-Z(4) Output Disable VIL VIH VIH X VIH Hi-Z Standby VIH X X X VIH Hi-Z Hi-Z X X X X VIL Hi-Z Hi-Z Reset 1. X = Don't care. 2. WAIT signal polarity is configured using the Set Configuration Register command. 3. L can be tied to VIH if the valid address has been previously latched. 4. Depends on G. 18/110 DQ15-DQ0 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 4 Command interface Command interface All Bus Write operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write operations. An internal Program/Erase Controller handles all timings and verifies the correct execution of the Program and Erase commands. The Program/Erase Controller provides a Status Register whose output may be read at any time to monitor the progress or the result of the operation. The Command Interface is reset to read mode when power is first applied, when exiting from Reset or whenever VDD is lower than VLKO. Command sequences must be followed exactly. Any invalid combination of commands will be ignored. Refer to Table 5: Command codes and Appendix D, Tables 43, 44, 45 and 46, Command Interface States - Modify and Lock Tables, for a summary of the Command Interface. The Command Interface is split into two types of commands: Standard commands and Factory Program commands. The following sections explain in detail how to perform each command. Table 5. Command codes Hex Code Command 01h Block Lock Confirm 03h Set Configuration Register Confirm 10h Alternative Program Setup 20h Block Erase Setup 2Fh Block Lock-Down Confirm 30h Enhanced Factory Program Setup 35h Double Word Program Setup 40h Program Setup 50h Clear Status Register 56h Quadruple Word Program Setup 60h Block Lock Setup, Block Unlock Setup, Block Lock Down Setup and Set Configuration Register Setup 70h Read Status Register 75h Quadruple Enhanced Factory Program Setup 80h Bank Erase Setup 90h Read Electronic Signature 98h Read CFI Query B0h Program/Erase Suspend C0h Protection Register Program D0h Program/Erase Resume, Block Erase Confirm, Bank Erase Confirm, Block Unlock Confirm or Enhanced Factory Program Confirm FFh Read Array 19/110 Command interface - standard commands 5 M58WR016QT, M58WR016QB, M58WR032QT, Command interface - standard commands The following commands are the basic commands used to read, write to and configure the device. Refer to Table 6: Standard commands, in conjunction with the following text descriptions. 5.1 Read Array command The Read Array command returns the addressed bank to Read Array mode. One Bus Write cycle is required to issue the Read Array command and return the addressed bank to Read Array mode. Subsequent read operations will read the addressed location and output the data. A Read Array command can be issued in one bank while programming or erasing in another bank. However if a Read Array command is issued to a bank currently executing a Program or Erase operation the command will be executed but the output data is not guaranteed. 5.2 Read Status Register command The Status Register indicates when a Program or Erase operation is complete and the success or failure of operation itself. Issue a Read Status Register command to read the Status Register content. The Read Status Register command can be issued at any time, even during Program or Erase operations. The following read operations output the content of the Status Register of the addressed bank. The Status Register is latched on the falling edge of E or G signals, and can be read until E or G returns to VIH. Either E or G must be toggled to update the latched data. See Table 9 for the description of the Status Register Bits. This mode supports asynchronous or single synchronous reads only. 5.3 Read Electronic Signature command The Read Electronic Signature command reads the Manufacturer and Device Codes, the Block Locking Status, the Protection Register, and the Configuration Register. The Read Electronic Signature command consists of one write cycle to an address within one of the banks. A subsequent Read operation in the same bank will output the Manufacturer Code, the Device Code, the protection Status of the blocks in the targeted bank, the Protection Register, or the Configuration Register (see Table 7). If a Read Electronic Signature command is issued in a bank that is executing a Program or Erase operation the bank will go into Read Electronic Signature mode, subsequent Bus Read cycles will output the Electronic Signature data and the Program/Erase controller will continue to program or erase in the background. This mode supports asynchronous or single synchronous reads only, it does not support page mode or synchronous burst reads. 20/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Command interface - standard com- 5.4 Read CFI Query command The Read CFI Query command is used to read data from the Common Flash Interface (CFI). The Read CFI Query Command consists of one Bus Write cycle, to an address within one of the banks. Once the command is issued subsequent Bus Read operations in the same bank read from the Common Flash Interface. If a Read CFI Query command is issued in a bank that is executing a Program or Erase operation the bank will go into Read CFI Query mode, subsequent Bus Read cycles will output the CFI data and the Program/Erase controller will continue to Program or Erase in the background. This mode supports asynchronous or single synchronous reads only, it does not support page mode or synchronous burst reads. The status of the other banks is not affected by the command (see Table 12). After issuing a Read CFI Query command, a Read Array command should be issued to the addressed bank to return the bank to Read Array mode. See Appendix B, Tables 33, 34, 35, 36, 37, 38, 39, 40, 41 and 42 for details on the information contained in the Common Flash Interface memory area. 5.5 Clear Status Register command The Clear Status Register command can be used to reset (set to ‘0’) error bits SR1, SR3, SR4 and SR5 in the Status Register. One bus write cycle is required to issue the Clear Status Register command. The Clear Status Register command does not change the Read mode of the bank. The error bits in the Status Register do not automatically return to ‘0’ when a new command is issued. The error bits in the Status Register should be cleared before attempting a new Program or Erase command. 21/110 Command interface - standard commands 5.6 M58WR016QT, M58WR016QB, M58WR032QT, Block Erase command The Block Erase command can be used to erase a block. It sets all the bits within the selected block to ’1’. All previous data in the block is lost. If the block is protected then the Erase operation will abort, the data in the block will not be changed and the Status Register will output the error. The Block Erase command can be issued at any moment, regardless of whether the block has been programmed or not. Two Bus Write cycles are required to issue the command. ● The first bus cycle sets up the Erase command. ● The second latches the block address in the internal state machine and starts the Program/Erase Controller. If the second bus cycle is not Write Erase Confirm (D0h), Status Register bits SR4 and SR5 are set and the command aborts. Erase aborts if Reset turns to VIL. As data integrity cannot be guaranteed when the Erase operation is aborted, the block must be erased again. Once the command is issued the device outputs the Status Register data when any address within the bank is read. At the end of the operation the bank will remain in Read Status Register mode until a Read Array, Read CFI Query or Read Electronic Signature command is issued. During Erase operations the bank containing the block being erased will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command, all other commands will be ignored. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being erased. Typical Erase times are given in Table 15: Program/Erase times and endurance cycles. See Appendix C, Figure 24: Block Erase flowchart and pseudo code, for a suggested flowchart for using the Block Erase command. 5.7 Program command The memory array can be programmed Word-by-Word. Only one Word in one bank can be programmed at any one time. If the block is protected, the program operation will abort, the data in the block will not be changed and the Status Register will output the error. Two bus write cycles are required to issue the Program Command. ● The first bus cycle sets up the Program command. ● The second latches the Address and the Data to be written and starts the Program/Erase Controller. After programming has started, read operations in the bank being programmed output the Status Register content. During Program operations the bank being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being programmed. Typical Program times are given in Table 15: Program/Erase times and endurance cycles. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory location must be reprogrammed. See Appendix C, Figure 20: Program flowchart and pseudo code, for the flowchart for using the Program command. 22/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Command interface - standard com- 5.8 Program/Erase Suspend command The Program/Erase Suspend command is used to pause a Program or Block Erase operation. A Bank Erase operation cannot be suspended. One bus write cycle is required to issue the Program/Erase command. Once the Program/Erase Controller has paused bits SR7, SR6 and/ or SR2 of the Status Register will be set to ‘1’. The command can be addressed to any bank. During Program/Erase Suspend the Command Interface will accept the Program/Erase Resume, Read Array (cannot read the erase-suspended block or the program-suspended Word), Read Status Register, Read Electronic Signature and Read CFI Query commands. Additionally, if the suspend operation was Erase then the Clear status Register, Program, Block Lock, Block Lock-Down or Block Unlock commands will also be accepted. The block being erased may be protected by issuing the Block Lock, Block Lock-Down or Protection Register Program commands. Only the blocks not being erased may be read or programmed correctly. When the Program/Erase Resume command is issued the operation will complete. Refer to the Dual Operations section for detailed information about simultaneous operations allowed during Program/Erase Suspend. During a Program/Erase Suspend, the device can be placed in standby mode by taking Chip Enable to VIH. Program/Erase is aborted if Reset turns to VIL. See Appendix C, Figure 23: Program Suspend & Resume flowchart and pseudo code, and Figure 25: Erase Suspend & Resume flowchart and pseudo code for flowcharts for using the Program/Erase Suspend command. 5.9 Program/Erase Resume command The Program/Erase Resume command can be used to restart the Program/Erase Controller after a Program/Erase Suspend command has paused it. One Bus Write cycle is required to issue the command. The command can be written to any address. The Program/Erase Resume command does not change the read mode of the banks. If the suspended bank was in Read Status Register, Read Electronic signature or Read CFI Query mode the bank remains in that mode and outputs the corresponding data. If the bank was in Read Array mode subsequent read operations will output invalid data. If a Program command is issued during a Block Erase Suspend, then the erase cannot be resumed until the programming operation has completed. It is possible to accumulate suspend operations. For example: suspend an erase operation, start a programming operation, suspend the programming operation then read the array. See Appendix C, Figure 23: Program Suspend & Resume flowchart and pseudo code, and Figure 25: Erase Suspend & Resume flowchart and pseudo code, for flowcharts for using the Program/Erase Resume command. 23/110 Command interface - standard commands 5.10 M58WR016QT, M58WR016QB, M58WR032QT, Protection Register Program command The Protection Register Program command is used to Program the 128 bit user One-TimeProgrammable (OTP) segment of the Protection Register and the Protection Register Lock. The segment is programmed 16 bits at a time. When shipped all bits in the segment are set to ‘1’. The user can only program the bits to ‘0’. Two write cycles are required to issue the Protection Register Program command. ● The first bus cycle sets up the Protection Register Program command. ● The second latches the Address and the Data to be written to the Protection Register and starts the Program/Erase Controller. Read operations output the Status Register content after the programming has started. The segment can be protected by programming bit 1 of the Protection Lock Register (see Figure 5: Protection Register Memory Map). Attempting to program a previously protected Protection Register will result in a Status Register error. The protection of the Protection Register is not reversible. The Protection Register Program cannot be suspended. See Appendix C, Figure 27: Protection Register Program flowchart and pseudo code, for a flowchart for using the Protection Register Program command. 5.11 Set Configuration Register command The Set Configuration Register command is used to write a new value to the Configuration Register which defines the burst length, type, X latency, Synchronous/Asynchronous Read mode and the valid Clock edge configuration. Two Bus Write cycles are required to issue the Set Configuration Register command. ● The first cycle writes the setup command and the address corresponding to the Configuration Register content. ● The second cycle writes the Configuration Register data and the confirm command. Read operations output the memory array content after the Set Configuration Register command is issued. The value for the Configuration Register is always presented on A0-A15. CR0 is on A0, CR1 on A1, etc.; the other address bits are ignored. 24/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Command interface - standard com- 5.12 Block Lock command The Block Lock command is used to lock a block and prevent Program or Erase operations from changing the data in it. All blocks are locked at power-up or reset. Two Bus Write cycles are required to issue the Block Lock command. ● The first bus cycle sets up the Block Lock command. ● The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Table 14 shows the Lock Status after issuing a Block Lock command. The Block Lock bits are volatile, once set they remain set until a hardware reset or powerdown/power-up. They are cleared by a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation. See Appendix C, Figure 26: Locking operations flowchart and pseudo code, for a flowchart for using the Lock command. 5.13 Block Unlock command The Block Unlock command is used to unlock a block, allowing the block to be programmed or erased. Two Bus Write cycles are required to issue the Block Unlock command. ● The first bus cycle sets up the Block Unlock command. ● The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Table 14 shows the protection status after issuing a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation and Appendix C, Figure 26: Locking operations flowchart and pseudo code, for a flowchart for using the Unlock command. 5.14 Block Lock-Down command A locked or unlocked block can be locked-down by issuing the Block Lock-Down command. A locked-down block cannot be programmed or erased, or have its protection status changed when WP is low, VIL. When WP is high, VIH, the Lock-Down function is disabled and the locked blocks can be individually unlocked by the Block Unlock command. Two Bus Write cycles are required to issue the Block Lock-Down command. ● The first bus cycle sets up the Block Lock command. ● The second Bus Write cycle latches the block address. The lock status can be monitored for each block using the Read Electronic Signature command. Locked-Down blocks revert to the locked (and not locked-down) state when the device is reset on power-down. Table 14 shows the Lock Status after issuing a Block LockDown command. Refer to the section, Block Locking, for a detailed explanation and Appendix C, Figure 26: Locking operations flowchart and pseudo code, for a flowchart for using the Lock-Down command. 25/110 Command interface - standard commands Table 6. M58WR016QT, M58WR016QB, M58WR032QT, Standard commands(1) Commands Cycles Bus Operations 1st Cycle 2nd Cycle Op. Add Data Op. Add Data Read Array 1+ Write BKA FFh Read WA RD Read Status Register 1+ Write BKA 70h Read BKA(2) SRD Read Electronic Signature 1+ Write BKA 90h Read BKA(2) ESD Read CFI Query 1+ Write BKA 98h Read BKA(2) QD Clear Status Register 1 Write X 50h Block Erase 2 Write BKA or BA(3) 20h Write BA D0h Program 2 Write BKA or WA(3) 40h or 10h Write WA PD Program/Erase Suspend 1 Write X B0h Program/Erase Resume 1 Write X D0h Protection Register Program 2 Write PRA C0h Write PRA PRD Set Configuration Register 2 Write CRD 60h Write CRD 03h Block Lock 2 Write BKA or BA(3) 60h Write BA 01h Block Unlock 2 Write BKA or BA(3) 60h Write BA D0h Block Lock-Down 2 Write BKA or BA(3) 60h Write BA 2Fh 1. X = Don't Care, WA=Word Address in targeted bank, RD=Read Data, SRD=Status Register Data, ESD=Electronic Signature Data, QD=Query Data, BA=Block Address, BKA= Bank Address, PD=Program Data, PRA=Protection Register Address, PRD=Protection Register Data, CRD=Configuration Register Data. 2. Must be same bank as in the first cycle. The signature addresses are listed in Table 7. 3. Any address within the bank can be used. 26/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Command interface - standard comTable 7. Electronic signature codes Code Address (h) Manufacturer Code Bank Address + 00 Data (h) 0020 Top Bank Address + 01 8812h (M58WR016QT) 8814h (M58WR032QT) Bottom Bank Address + 01 8813h (M58WR016QB) 8815h (M58WR032QB) Device Code Locked 0001 Unlocked 0000 Locked and LockedDown Block Protection Block Address + 02 Unlocked and LockedDown 0003 0002 Reserved Bank Address + 03 Reserved Configuration Register Bank Address + 05 CR(1) Numonyx Factory Default Protection Register Lock OTP Area Permanently Locked 0002 Bank Address + 80 0000 Bank Address + 81 Bank Address + 84 Unique Device Number Bank Address + 85 Bank Address + 8C OTP Area Protection Register 1. CR = Configuration Register. Figure 5. Protection Register Memory Map PROTECTION REGISTER 8Ch User Programmable OTP 85h 84h Unique device number 81h 80h Protection Register Lock 1 0 AI08149 27/110 Command interface - factory program commands 6 M58WR016QT, M58WR016QB, M58WR032QT, Command interface - factory program commands The Factory Program commands are used to speed up programming. They require VPP to be at VPPH except for the Bank Erase command which also operates at VPP = VDD. Refer to Table 8: Factory Program commands, in conjunction with the following text descriptions. The use of Factory Program commands requires certain operating conditions. 6.1 ● VPP must be set to VPPH (except for Bank Erase comand), ● VDD must be within operating range, ● Ambient temperature, TA must be 25°C ± 5°C, ● The targeted block must be unlocked. Bank Erase command The Bank Erase command can be used to erase a bank. It sets all the bits within the selected bank to ’1’. All previous data in the bank is lost. The Bank Erase command will ignore any protected blocks within the bank. If all blocks in the bank are protected then the Bank Erase operation will abort and the data in the bank will not be changed. The Status Register will not output any error. Bank Erase operations can be performed at both VPP = VPPH and VPP = VDD. Two Bus Write cycles are required to issue the command. ● The first bus cycle sets up the Bank Erase command. ● The second latches the bank address in the internal state machine and starts the Program/Erase Controller. If the second bus cycle is not Write Bank Erase Confirm (D0h), Status Register bits SR4 and SR5 are set and the command aborts. Erase aborts if Reset turns to VIL. As data integrity cannot be guaranteed when the Erase operation is aborted, the bank must be erased again. Once the command is issued the device outputs the Status Register data when any address within the bank is read. At the end of the operation the bank will remain in Read Status Register mode until a Read Array, Read CFI Query or Read Electronic Signature command is issued. During Bank Erase operations the bank being erased will only accept the Read Array, Read Status Register, Read Electronic Signature and Read CFI Query command, all other commands will be ignored. For optimum performance, Bank Erase commands should be limited to a maximum of 100 Program/Erase cycles per Block. After 100 Program/Erase cycles the internal algorithm will still operate properly but some degradation in performance may occur. Dual Operations are not supported during Bank Erase operations and the command cannot be suspended. Typical Erase times are given in Table 15: Program/Erase times and endurance cycles. 28/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 6.2 Command interface - factory pro- Double Word Program command The Double Word Program command improves the programming throughput by writing a page of two adjacent words in parallel. The two words must differ only for the address A0. If the block is protected, the Double Word Program operation will abort, the data in the block will not be changed and the Status Register will output the error. Three bus write cycles are necessary to issue the Double Word Program command. ● The first bus cycle sets up the Double Word Program Command. ● The second bus cycle latches the Address and the Data of the first word to be written. ● The third bus cycle latches the Address and the Data of the second word to be written and starts the Program/Erase Controller. Read operations in the bank being programmed output the Status Register content after the programming has started. During Double Word Program operations the bank being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature and Read CFI Query command, all other commands will be ignored. Dual operations are not supported during Double Word Program operations and the command cannot be suspended. Typical Program times are given in Table 15: Program/Erase times and endurance cycles. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory locations must be reprogrammed. See Appendix C, Figure 21: Double Word Program flowchart and pseudo code, for the flowchart for using the Double Word Program command. 29/110 Command interface - factory program commands 6.3 M58WR016QT, M58WR016QB, M58WR032QT, Quadruple Word Program command The Quadruple Word Program command improves the programming throughput by writing a page of four adjacent words in parallel. The four words must differ only for the addresses A0 and A1. If the block is protected, the Quadruple Word Program operation will abort, the data in the block will not be changed and the Status Register will output the error. Five bus write cycles are necessary to issue the Quadruple Word Program command. ● The first bus cycle sets up the Double Word Program Command. ● The second bus cycle latches the Address and the Data of the first word to be written. ● The third bus cycle latches the Address and the Data of the second word to be written. ● The fourth bus cycle latches the Address and the Data of the third word to be written. ● The fifth bus cycle latches the Address and the Data of the fourth word to be written and starts the Program/Erase Controller. Read operations to the bank being programmed output the Status Register content after the programming has started. Programming aborts if Reset goes to VIL. As data integrity cannot be guaranteed when the program operation is aborted, the memory locations must be reprogrammed. During Quadruple Word Program operations the bank being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature and Read CFI Query command, all other commands will be ignored. Dual operations are not supported during Quadruple Word Program operations and the command cannot be suspended. Typical Program times are given in Table 15: Program/Erase times and endurance cycles. See Appendix C, Figure 22: Quadruple Word Program flowchart and pseudo code, for the flowchart for using the Quadruple Word Program command. 6.4 Enhanced Factory Program command The Enhanced Factory Program command can be used to program large streams of data within any one block. It greatly reduces the total programming time when a large number of Words are written to a block at any one time. Dual operations are not supported during the Enhanced Factory Program operation and the command cannot be suspended. For optimum performance the Enhanced Factory Program commands should be limited to a maximum of 10 program/erase cycles per block. If this limit is exceeded the internal algorithm will continue to work properly but some degradation in performance is possible. Typical Program times are given in Table 15. If the block is protected, the Enhanced Factory Program operation will abort, the data in the block will not be changed and the Status Register will output the error. The Enhanced Factory Program command has four phases: the Setup Phase, the Program Phase to program the data to the memory, the Verify Phase to check that the data has been correctly programmed and reprogram if necessary and the Exit Phase. Refer to Table 8: Factory Program commands, and Figure 28: Enhanced Factory Program flowchart. 30/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 6.4.1 Command interface - factory pro- Setup Phase The Enhanced Factory Program command requires two Bus Write operations to initiate the command. ● The first bus cycle sets up the Enhanced Factory Program command. ● The second bus cycle confirms the command. The Status Register P/E.C. Bit SR7 should be read to check that the P/E.C. is ready. After the confirm command is issued, read operations output the Status Register data. The read Status Register command must not be issued as it will be interpreted as data to program. 6.4.2 Program Phase The Program Phase requires n+1 cycles, where n is the number of Words (refer to Table 8: Factory Program commands, and Figure 28: Enhanced Factory Program flowchart). Three successive steps are required to issue and execute the Program Phase of the command. 1. Use one Bus Write operation to latch the Start Address and the first Word to be programmed. The Status Register Bank Write Status bit SR0 should be read to check that the P/E.C. is ready for the next Word. 2. Each subsequent Word to be programmed is latched with a new Bus Write operation. The address can either remain the Start Address, in which case the P/E.C. increments the address location or the address can be incremented in which case the P/E.C. jumps to the new address. If any address that is not in the same block as the Start Address is given with data FFFFh, the Program Phase terminates and the Verify Phase begins. The Status Register bit SR0 should be read between each Bus Write cycle to check that the P/E.C. is ready for the next Word. 3. Finally, after all Words have been programmed, write one Bus Write operation with data FFFFh to any address outside the block containing the Start Address, to terminate the programming phase. If the data is not FFFFh, the command is ignored. The memory is now set to enter the Verify Phase. 31/110 Command interface - factory program commands 6.4.3 M58WR016QT, M58WR016QB, M58WR032QT, Verify Phase The Verify Phase is similar to the Program Phase in that all Words must be resent to the memory for them to be checked against the programmed data. The Program/Erase Controller checks the stream of data with the data that was programmed in the Program Phase and reprograms the memory location if necessary. Three successive steps are required to execute the Verify Phase of the command. 1. Use one Bus Write operation to latch the Start Address and the first Word, to be verified. The Status Register bit SR0 should be read to check that the Program/Erase Controller is ready for the next Word. 2. Each subsequent Word to be verified is latched with a new Bus Write operation. The Words must be written in the same order as in the Program Phase. The address can remain the Start Address or be incremented. If any address that is not in the same block as the Start Address is given with data FFFFh, the Verify Phase terminates. Status Register bit SR0 should be read to check that the P/E.C. is ready for the next Word. 3. Finally, after all Words have been verified, write one Bus Write operation with data FFFFh to any address outside the block containing the Start Address, to terminate the Verify Phase. If the Verify Phase is successfully completed the memory remains in Read Status Register mode. If the Program/Erase Controller fails to reprogram a given location, the error will be signaled in the Status Register. 6.4.4 Exit Phase Status Register P/E.C. bit SR7 set to ‘1’ indicates that the device has returned to Read mode. A full Status Register check should be done to ensure that the block has been successfully programmed. See the section on the Status Register for more details. 6.5 Quadruple Enhanced Factory Program command The Quadruple Enhanced Factory Program command can be used to program one or more pages of four adjacent words in parallel. The four words must differ only for the addresses A0 and A1. Dual operations are not supported during Quadruple Enhanced Factory Program operations and the command cannot be suspended. If the block is protected, the Quadruple Enhanced Factory Program operation will abort, the data in the block will not be changed and the Status Register will output the error. The Quadruple Enhanced Factory Program command has four phases: the Setup Phase, the Load Phase where the data is loaded into the buffer, the combined Program and Verify Phase where the loaded data is programmed to the memory and then automatically checked and reprogrammed if necessary and the Exit Phase. Unlike the Enhanced Factory Program it is not necessary to resubmit the data for the Verify Phase. The Load Phase and the Program and Verify Phase can be repeated to program any number of pages within the block. 32/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 6.5.1 Command interface - factory pro- Setup Phase The Quadruple Enhanced Factory Program command requires one Bus Write operation to initiate the load phase. After the setup command is issued, read operations output the Status Register data. The Read Status Register command must not be issued as it will be interpreted as data to program. 6.5.2 Load Phase The Load Phase requires 4 cycles to load the data (refer to Table 8: Factory Program commands, and Figure 29: Quadruple Enhanced Factory Program flowchart). Once the first Word of each Page is written it is impossible to exit the Load phase until all four Words have been written. Two successive steps are required to issue and execute the Load Phase of the Quadruple Enhanced Factory Program command. 1. Use one Bus Write operation to latch the Start Address and the first Word of the first Page to be programmed. For subsequent Pages the first Word address can remain the Start Address (in which case the next Page is programmed) or can be any address in the same block. If any address with data FFFFh is given that is not in the same block as the Start Address, the device enters the Exit Phase. For the first Load Phase Status Register bit SR7 should be read after the first Word has been issued to check that the command has been accepted (bit SR7 set to ‘0’). This check is not required for subsequent Load Phases. 2. Each subsequent Word to be programmed is latched with a new Bus Write operation. The address is only checked for the first Word of each Page as the order of the Words to be programmed is fixed. The memory is now set to enter the Program and Verify Phase. 6.5.3 Program and Verify Phase In the Program and Verify Phase the four Words that were loaded in the Load Phase are programmed in the memory array and then verified by the Program/Erase Controller. If any errors are found the Program/Erase Controller reprograms the location. During this phase the Status Register shows that the Program/Erase Controller is busy, Status Register bit SR7 set to ‘0’, and that the device is not waiting for new data, Status Register bit SR0 set to ‘1’. When Status Register bit SR0 is set to ‘0’ the Program and Verify phase has terminated. Once the Verify Phase has successfully completed subsequent pages in the same block can be loaded and programmed. The device returns to the beginning of the Load Phase by issuing one Bus Write operation to latch the Address and the first of the four new Words to be programmed. 6.5.4 Exit Phase Finally, after all the pages have been programmed, write one Bus Write operation with data FFFFh to any address outside the block containing the Start Address, to terminate the Load and Program and Verify Phases. Status Register bit SR7 set to ‘1’ and bit SR0 set to ‘0’ indicate that the Quadruple Enhanced Factory Program command has terminated. A full Status Register check should be done to ensure that the block has been successfully programmed. See the section on the Status Register for more details. 33/110 Command interface - factory program commands M58WR016QT, M58WR016QB, M58WR032QT, If the Program and Verify Phase has successfully completed the memory returns to Read mode. If the P/E.C. fails to program and reprogram a given location, the error will be signaled in the Status Register. Table 8. Factory Program commands(1) Command Phase Cycles Bus Write Operations 1st 2nd 3rd Add Data Add Data Final -1 Add Data Final Add Data Add Data WA3 PD3 WA4 PD4 Bank Erase 2 BKA 80h BKA D0h Double Word Program(2) 3 BKA or WA1(3) 35h WA1 PD1 WA2 PD2 Quadruple Word Program(4) 5 BKA or WA1(3) 56h WA1 PD1 WA2 PD2 2+ n+1 BKA or WA1(3) 30h BA or WA1(6) D0h WA1(7) PD1 WAn(8) PAn NOT FFFFh WA1(7) n+1 WA1(7) PD1 WA2(8) PD2 WA3(8) PD3 WAn(8) PAn NOT FFFFh WA1(7) 5 BKA or WA1(3) 75h WA1(7) PD1 WA2(9) PD2 WA3(9) PD3 WA4(9) Setup, Enhanced Program Factory Program(5) Verify, Exit Setup, first Load First Program & Verify Quadruple Enhanced Subsequent Factory Loads Program(4)(5) Subsequent Program & Verify Exit PD4 Automatic 4 WA1i(7) PD1i WA2i(9) PD2i WA3i(9) PD3i WA4i(9) PD4i Automatic 1 NOT FFFFh WA1(7) 1. WA=Word Address in targeted bank, BKA= Bank Address, PD=Program Data, BA=Block Address. 2. Word Addresses 1 and 2 must be consecutive Addresses differing only for A0. 3. Any address within the bank can be used. 4. Word Addresses 1,2,3 and 4 must be consecutive Addresses differing only for A0 and A1. 5. A Bus Read must be done between each Write cycle where the data is programmed or verified to read the Status Register and check that the memory is ready to accept the next data. n = number of Words, i = number of Pages to be programmed. 6. Any address within the block can be used. 7. WA1 is the Start Address. NOT WA1 is any address that is not in the same block as WA1. 8. Address can remain Starting Address WA1 or be incremented. 9. Address is only checked for the first Word of each Page as the order to program the Words in each page is fixed so subsequent Words in each Page can be written to any address. 34/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 7 Status Register Status Register The Status Register provides information on the current or previous Program or Erase operations. Issue a Read Status Register command to read the contents of the Status Register, refer to Read Status Register Command section for more details. To output the contents, the Status Register is latched and updated on the falling edge of the Chip Enable or Output Enable signals and can be read until Chip Enable or Output Enable returns to VIH. The Status Register can only be read using single asynchronous or single synchronous reads. Bus Read operations from any address within the bank, always read the Status Register during Program and Erase operations. The various bits convey information about the status and any errors of the operation. Bits SR7, SR6, SR2 and SR0 give information on the status of the device and are set and reset by the device. Bits SR5, SR4, SR3 and SR1 give information on errors, they are set by the device but must be reset by issuing a Clear Status Register command or a hardware reset. If an error bit is set to ‘1’ the Status Register should be reset before issuing another command. SR7 to SR1 refer to the status of the device while SR0 refers to the status of the addressed bank. The bits in the Status Register are summarized in Table 9: Status Register bits. Refer to Table 9 in conjunction with the following text descriptions. 7.0.1 Program/Erase Controller Status Bit (SR7) The Program/Erase Controller Status bit indicates whether the Program/Erase Controller is active or inactive in any bank. When the Program/Erase Controller Status bit is Low (set to ‘0’), the Program/Erase Controller is active; when the bit is High (set to ‘1’), the Program/Erase Controller is inactive, and the device is ready to process a new command. The Program/Erase Controller Status is Low immediately after a Program/Erase Suspend command is issued until the Program/Erase Controller pauses. After the Program/Erase Controller pauses the bit is High. During Program, Erase, operations the Program/Erase Controller Status bit can be polled to find the end of the operation. Other bits in the Status Register should not be tested until the Program/Erase Controller completes the operation and the bit is High. After the Program/Erase Controller completes its operation the Erase Status, Program Status, VPP Status and Block Lock Status bits should be tested for errors. 7.0.2 Erase Suspend Status Bit (SR6) The Erase Suspend Status bit indicates that an Erase operation has been suspended or is going to be suspended in the addressed block. When the Erase Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. The Erase Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR7 is set within the Erase Suspend Latency time of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Erase Suspend Status bit returns Low. 35/110 Status Register 7.0.3 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Erase Status Bit (SR5) The Erase Status bit can be used to identify if the memory has failed to verify that the block or bank has erased correctly. When the Erase Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the block or bank and still failed to verify that it has erased correctly. The Erase Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). Once set High, the Erase Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. 7.0.4 Program Status Bit (SR4) The Program Status bit is used to identify a Program failure or an attempt to program a ‘1’ to an already programmed bit when VPP = VPPH. When the Program Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the byte and still failed to verify that it has programmed correctly. After an attempt to program a '1' to an already programmed bit, the Program Status bit SR4 only goes High (set to '1') if VPP = VPPH (if VPP is different from VPPH, SR4 remains Low (set to '0') and the attempt is not shown). The Program Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). Once set High, the Program Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new command is issued, otherwise the new command will appear to fail. 7.0.5 VPP Status Bit (SR3) The VPP Status bit can be used to identify an invalid voltage on the VPP pin during Program and Erase operations. The VPP pin is only sampled at the beginning of a Program or Erase operation. Indeterminate results can occur if VPP becomes invalid during an operation. When the VPP Status bit is Low (set to ‘0’), the voltage on the VPP pin was sampled at a valid voltage; when the VPP Status bit is High (set to ‘1’), the VPP pin has a voltage that is below the VPP Lockout Voltage, VPPLK, the memory is protected and Program and Erase operations cannot be performed. Once set High, the VPP Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. 36/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 7.0.6 Status Register Program Suspend Status Bit (SR2) The Program Suspend Status bit indicates that a Program operation has been suspended in the addressed block. When the Program Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. The Program Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR2 is set within the Program Suspend Latency time of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Program Suspend Status bit returns Low. 7.0.7 Block Protection Status Bit (SR1) The Block Protection Status bit can be used to identify if a Program or Block Erase operation has tried to modify the contents of a locked block. When the Block Protection Status bit is High (set to ‘1’), a Program or Erase operation has been attempted on a locked block. Once set High, the Block Protection Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset before a new command is issued, otherwise the new command will appear to fail. 7.0.8 Bank Write/Multiple Word Program Status Bit (SR0) The Bank Write Status bit indicates whether the addressed bank is programming or erasing. In Enhanced Factory Program mode the Multiple Word Program bit shows if a Word has finished programming or verifying depending on the phase. The Bank Write Status bit should only be considered valid when the Program/Erase Controller Status SR7 is Low (set to ‘0’). When both the Program/Erase Controller Status bit and the Bank Write Status bit are Low (set to ‘0’), the addressed bank is executing a Program or Erase operation. When the Program/Erase Controller Status bit is Low (set to ‘0’) and the Bank Write Status bit is High (set to ‘1’), a Program or Erase operation is being executed in a bank other than the one being addressed. In Enhanced Factory Program mode if Multiple Word Program Status bit is Low (set to ‘0’), the device is ready for the next Word, if the Multiple Word Program Status bit is High (set to ‘1’) the device is not ready for the next Word. Note: Refer to Appendix C: Flowcharts and pseudo codes, for using the Status Register. 37/110 Status Register M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 9. Bit SR7 SR6 SR5 SR4 SR3 SR2 SR1 Status Register bits Name Type P/E.C. Status Status Erase Suspend Status Status Erase Status Error Program Status Logic Level(1) Definition '1' Ready '0' Busy '1' Erase Suspended '0' Erase In progress or Completed '1' Erase Error '0' Erase Success '1' Program Error '0' Program Success '1' VPP Invalid, Abort '0' VPP OK '1' Program Suspended '0' Program In Progress or Completed '1' Program/Erase on protected Block, Abort '0' No operation to protected blocks Error VPP Status Error Program Suspend Status Status Block Protection Status Error SR7 = ‘1’ Not Allowed '1' Bank Write Status SR7 = ‘0’ Program or erase operation in a bank other than the addressed bank SR7 = ‘1’ No Program or erase operation in the device SR7 = ‘0’ Program or erase operation in addressed bank Status '0' SR0 SR7 = ‘1’ Not Allowed Multiple Word Program Status Status (Enhanced Factory Program mode) '1' SR7 = ‘0’ SR7 = ‘1’ the device is exiting from EFP '0' SR7 = ‘0’ 1. Logic level '1' is High, '0' is Low. 38/110 the device is NOT ready for the next word the device is ready for the next Word M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 8 Configuration Register Configuration Register The Configuration Register is used to configure the type of bus access that the memory will perform. Refer to Read Modes section for details on read operations. The Configuration Register is set through the Command Interface. After a Reset or PowerUp the device is configured for asynchronous page read (CR15 = 1). The Configuration Register bits are described in Table 10. They specify the selection of the burst length, burst type, burst X latency and the Read operation. Refer to Figures 6 and 7 for examples of synchronous burst configurations. 8.1 Read Select Bit (CR15) The Read Select bit, CR15, is used to switch between asynchronous and synchronous Bus Read operations. When the Read Select bit is set to ’1’, read operations are asynchronous; when the Read Select bit is set to ’0’, read operations are synchronous. Synchronous Burst Read is supported in both parameter and main blocks and can be performed across banks. On reset or power-up the Read Select bit is set to’1’ for asynchronous access. 8.2 X-Latency Bits (CR13-CR11) The X-Latency bits are used during Synchronous Read operations to set the number of clock cycles between the address being latched and the first data becoming available. For correct operation the X-Latency bits can only assume the values in Table 10: Configuration Register bits. The correspondence between X-Latency settings and the maximum sustainable frequency must be calculated taking into account some system parameters. Two conditions must be satisfied: 1. Depending on whether tAVK_CPU or tDELAY is supplied either one of the following two equations must be satisfied: (n + 1) tK ≥ tACC - tAVK_CPU + tQVK_CPU (n + 2) tK ≥ tACC + tDELAY + tQVK_CPU 2. and also tK > tKQV + tQVK_CPU where: ● n is the chosen X-Latency configuration code ● tK is the clock period ● tAVK_CPU is clock to address valid, L Low, or E Low, whichever occurs last ● tDELAY is address valid, L Low, or E Low to clock, whichever occurs last ● tQVK_CPU is the data setup time required by the system CPU, ● tKQV is the clock to data valid time ● tACC is the random access time of the device. Refer to Figure 6: X-Latency and data output configuration example. 39/110 Configuration Register 8.3 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Wait Polarity Bit (CR10) In synchronous burst mode the Wait signal indicates whether the output data are valid or a WAIT state must be inserted. The Wait Polarity bit is used to set the polarity of the Wait signal. When the Wait Polarity bit is set to ‘0’ the Wait signal is active Low. When the Wait Polarity bit is set to ‘1’ the Wait signal is active High (default). 8.4 Data Output Configuration Bit (CR9) The Data Output Configuration bit determines whether the output remains valid for one or two clock cycles. When the Data Output Configuration Bit is ’0’ the output data is valid for one clock cycle, when the Data Output Configuration Bit is ’1’ the output data is valid for two clock cycles. The Data Output Configuration depends on the condition: ● tK > tKQV + tQVK_CPU where tK is the clock period, tQVK_CPU is the data setup time required by the system CPU and tKQV is the clock to data valid time. If this condition is not satisfied, the Data Output Configuration bit should be set to ‘1’ (two clock cycles). Refer to Figure 6: X-Latency and data output configuration example. 8.5 Wait Configuration Bit (CR8) In burst mode the Wait bit controls the timing of the Wait output pin, WAIT. When WAIT is asserted, Data is Not Valid and when WAIT is deasserted, Data is Valid. When the Wait bit is ’0’ the Wait output pin is asserted during the wait state. When the Wait bit is ’1’ (default) the Wait output pin is asserted one clock cycle before the wait state. 8.6 Burst Type Bit (CR7) The Burst Type bit is used to configure the sequence of addresses read as sequential or interleaved. When the Burst Type bit is ’0’ the memory outputs from interleaved addresses; when the Burst Type bit is ’1’ (default) the memory outputs from sequential addresses. See Table 11: Burst type definition, for the sequence of addresses output from a given starting address in each mode. 8.7 Valid Clock Edge Bit (CR6) The Valid Clock Edge bit, CR6, is used to configure the active edge of the Clock, K, during Synchronous Burst Read operations. When the Valid Clock Edge bit is ’0’ the falling edge of the Clock is the active edge; when the Valid Clock Edge bit is ’1’ the rising edge of the Clock is active. 8.8 Wrap Burst Bit (CR3) The burst reads can be confined inside the 4 or 8 Word boundary (wrap) or overcome the boundary (no wrap). The Wrap Burst bit is used to select between wrap and no wrap. When 40/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Configuration Register the Wrap Burst bit is set to ‘0’ the burst read wraps; when it is set to ‘1’ the burst read does not wrap. 8.9 Burst length Bits (CR2-CR0) The Burst Length bits set the number of Words to be output during a Synchronous Burst Read operation as result of a single address latch cycle. They can be set for 4 Words, 8 Words, 16 Words or continuous burst, where all the words are read sequentially. In continuous burst mode the burst sequence can cross bank boundaries. In continuous burst mode or in 4, 8, 16 Words no-wrap, depending on the starting address, the device asserts the WAIT output to indicate that a delay is necessary before the data is output. If the starting address is aligned to a 4 Word boundary no wait states are needed and the WAIT output is not asserted. If the starting address is shifted by 1,2 or 3 positions from the four word boundary, WAIT will be asserted for 1, 2 or 3 clock cycles when the burst sequence crosses the first 16 Word boundary, to indicate that the device needs an internal delay to read the successive words in the array. WAIT will be asserted only once during a continuous burst access. See also Table 11: Burst type definition. CR14, CR5 and CR4 are reserved for future use. 41/110 Configuration Register Table 10. Bit CR15 CR14 CR13-CR11 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Configuration Register bits Description Value Description 0 Synchronous Read 1 Asynchronous Read (Default at power-on) 010 2 clock latency 011 3 clock latency 100 4 clock latency 101 5 clock latency 111 Reserved (default) Read Select Reserved X-Latency Other configurations reserved CR10 CR9 CR8 CR7 CR6 CR5-CR4 CR3 CR2-CR0 42/110 0 WAIT is active Low 1 WAIT is active high (default) 0 Data held for one clock cycle 1 Data held for two clock cycles (default) 0 WAIT is active during wait state 1 WAIT is active one data cycle before wait state (default) 0 Interleaved 1 Sequential (default) 0 Falling Clock edge 1 Rising Clock edge (default) 0 Wrap 1 No Wrap (default) 001 4 Words 010 8 Words 011 16 Words 111 Continuous (CR7 must be set to ‘1’) (default) Wait Polarity Data Output Configuration Wait Configuration Burst Type Valid Clock Edge Reserved Wrap Burst Burst Length M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Mode Table 11. Start Add Configuration Register Burst type definition 4 Words 8 Words Sequential Interleaved Sequential Interleaved 16 Words Sequential Interleaved Continuous Burst 0 0-1-2-3 0-1-2-3 0-1-2-3-4-5-60-1-2-3-4-5- 0-1-2-3-4-5- 0-1-2-3-4-5-6-7-8-97-8-9-10-11- 0-1-2-3-4-5-6... 6-7 6-7 10-11-12-13-14-15 12-13-14-15 1 1-2-3-0 1-0-3-2 1-2-3-4-5-6-7-8-9- 1-0-3-2-5-4-7- 1-2-3-4-5-6-71-2-3-4-5-6- 1-0-3-2-5-410-11-12-13-14-15- 6-9-8-11-10- ...15-WAIT-167-0 7-6 0 13-12-15-14 17-18... 2 2-3-0-1 2-3-0-1 2-3-0-1-6-7-4- 2-3-4-5-6-7...152-3-4-5-6-7- 2-3-0-1-6-7- 2-3-4-5-6-7-8-9-105-10-11-8-9- WAIT-WAIT-160-1 4-5 11-12-13-14-15-0-1 14-15-12-13 17-18... 3 3-0-1-2 3-2-1-0 3-4-5-6-7-8-9-10- 3-2-1-0-7-6-5- 3-4-5-6-7...153-4-5-6-7-0- 3-2-1-0-7-611-12-13-14-15-0- 4-11-10-9-8WAIT-WAIT1-2 5-4 1-2 15-14-13-12 WAIT-16-17-18... 7-6-5-4 7-8-9-10-11-127-6-5-4-3-2-17-0-1-2-3-4- 7-6-5-4-3-2- 7-8-9-10-11-12-1313-14-15-WAIT0-15-14-135-6 1-0 14-15-0-1-2-3-4-5-6 WAIT-WAIT-1612-11-10-9-8 17... Wrap ... 7 7-4-5-6 ... 12 12-13-14-15-1617-18... 13 13-14-15-WAIT16-17-18... 14 14-15-WAITWAIT-16-1718.... 15 15-WAIT-WAITWAIT-16-17-18... 43/110 Configuration Register Mode Table 11. Start Add M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Burst type definition (continued) 4 Words 8 Words Sequential Interleaved Sequential Interleaved 16 Words Sequential Interleaved 0 0-1-2-3 0-1-2-3-4-56-7 0-1-2-3-4-5-6-7-8-910-11-12-13-14-15 1 1-2-3-4 1-2-3-4-5-67-8 1-2-3-4-5-6-7-8-910-11-12-13-14-15WAIT-16 2 2-3-4-5 2-3-4-5-6-78-9... 2-3-4-5-6-7-8-9-1011-12-13-14-15WAIT-WAIT-16-17 3-4-5-6 3-4-5-6-7-89-10 3-4-5-6-7-8-9-1011-12-13-14-15WAIT-WAIT-WAIT16-17-18 7-8-9-10 7-8-9-10-1112-13-14 7-8-9-10-11-12-1314-15-WAIT-WAITWAIT-16-17-18-1920-21-22 12 12-13-1415 12-13-1415-16-1718-19 12-13-14-15-16-1718-19-20-21-22-2324-25-26-27 13 13-14-15WAIT-16 13-14-15WAIT-16-1718-19-20 13-14-15-WAIT-1617-18-19-20-21-2223-24-25-26-27-28 14 14-15WAITWAIT-1617 14-15-WAITWAIT-16-1718-19-20-21 14-15-WAIT-WAIT16-17-18-19-20-2122-23-24-25-26-2728-29 15 15-WAITWAITWAIT-1617-18 15-WAITWAIT-WAIT16-17-1819-20-21-22 15-WAIT-WAITWAIT-16-17-18-1920-21-22-23-24-2526-27-28-29-30 3 Continuous Burst No-wrap ... 7 Same as for Wrap (Wrap /No Wrap has no effect on Continuous Burst) ... Figure 6. X-Latency and data output configuration example X-latency 1st cycle 2nd cycle 3rd cycle 4th cycle K E L Amax-A0 VALID ADDRESS 44/110 tDELAY tAVK_CPU tQVK_CPU tACC tK tKQV tQVK_CPU DQ15-DQ0 VALID DATA VALID DATA Notes: 1. Settings shown: X-latency = 4, Data Output held for one clock cycle. 2. Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. AI10174 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 7. Configuration Register Wait configuration example E K L Amax-A0(1) DQ15-DQ0 VALID ADDRESS VALID DATA VALID DATA NOT VALID VALID DATA WAIT CR8 = '0' CR10 = '0' WAIT CR8 = '1' CR10 = '0' WAIT CR8 = '0' CR10 = '1' WAIT CR8 = '1' CR10 = '1' Note: Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. AI10175 45/110 Read modes 9 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Read modes Read operations can be performed in two different ways depending on the settings in the Configuration Register. If the clock signal is ‘don’t care’ for the data output, the read operation is Asynchronous; if the data output is synchronized with clock, the read operation is Synchronous. The Read mode and data output format are determined by the Configuration Register. (See Configuration Register section for details). All banks supports both asynchronous and synchronous read operations. The Multiple Bank architecture allows read operations in one bank, while write operations are being executed in another (see Tables 12 and 13). 9.1 Asynchronous Read mode In Asynchronous Read operations the clock signal is ‘don’t care’. The device outputs the data corresponding to the address latched, that is the memory array, Status Register, Common Flash Interface or Electronic Signature depending on the command issued. CR15 in the Configuration Register must be set to ‘1’ for Asynchronous operations. In Asynchronous Read mode a Page of data is internally read and stored in a Page Buffer. The Page has a size of 4 Words and is addressed by A0 and A1 address inputs. The address inputs A0 and A1 are not gated by Latch Enable in Asynchronous Read mode. The first read operation within the Page has a longer access time (Tacc, Random access time), subsequent reads within the same Page have much shorter access times. If the Page changes then the normal, longer timings apply again. Asynchronous Read operations can be performed in two different ways, Asynchronous Random Access Read and Asynchronous Page Read. Only Asynchronous Page Read takes full advantage of the internal page storage so different timings are applied. During Asynchronous Read operations, after a bus inactivity of 150ns, the device automatically switches to the Automatic Standby mode. In this condition the power consumption is reduced to the standby value and the outputs are still driven. In Asynchronous Read mode, the WAIT signal is always asserted. See Table 21: Asynchronous Read AC characteristics, Figure 10: Asynchronous Random Access Read AC waveforms, and Figure 11: Asynchronous Page Read AC waveforms for details. 46/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 9.2 Read modes Synchronous Burst Read mode In Synchronous Burst Read mode the data is output in bursts synchronized with the clock. It is possible to perform burst reads across bank boundaries. Synchronous Burst Read mode can only be used to read the memory array. For other read operations, such as Read Status Register, Read CFI and Read Electronic Signature, Single Synchronous Read or Asynchronous Random Access Read must be used. In Synchronous Burst Read mode the flow of the data output depends on parameters that are configured in the Configuration Register. A burst sequence is started at the first clock edge (rising or falling depending on Valid Clock Edge bit CR6 in the Configuration Register) after the falling edge of Latch Enable or Chip Enable, whichever occurs last. Addresses are internally incremented and after a delay of 2 to 5 clock cycles (X latency bits CR13-CR11) the corresponding data are output on each clock cycle. The number of Words to be output during a Synchronous Burst Read operation can be configured as 4, 8, 16 Words, or Continuous (Burst Length bits CR2-CR0). The data can be configured to remain valid for one or two clock cycles (Data Output Configuration bit CR9). The order of the data output can be modified through the Burst Type and the Wrap Burst bits in the Configuration Register. The burst sequence may be configured to be sequential or interleaved (CR7). The burst reads can be confined inside the 4, 8 or 16 Word boundary (Wrap) or overcome the boundary (No Wrap). If the starting address is aligned to the Burst Length (4, 8 or 16 Words) the wrapped configuration has no impact on the output sequence. Interleaved mode is not allowed in Continuous Burst Read mode or with No Wrap sequences. A WAIT signal may be asserted to indicate to the system that an output delay will occur. This delay will depend on the starting address of the burst sequence; the worst case delay will occur when the sequence is crossing a 16 Word boundary and the starting address was at the end of a four word boundary. WAIT is asserted during X latency, the Wait state and at the end of 4-, 8- or 16-Word burst. It is only deasserted when output data are valid. In Continuous Burst Read mode a Wait state will occur when crossing the first 16 Word boundary. If the burst starting address is aligned to a 4 Word Page, the Wait state will not occur. The WAIT signal can be configured to be active Low or active High (default) by setting CR10 in the Configuration Register. The WAIT signal is meaningful only in Synchronous Burst Read mode, in other modes, WAIT is always asserted (except for Read Array mode). See Table 22: Synchronous Read AC characteristics, and Figure 12: Synchronous Burst Read AC waveforms, for details. 47/110 Read modes 9.2.1 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Synchronous Burst Read Suspend A Synchronous Burst Read operation can be suspended, freeing the data bus for other higher priority devices. It can be suspended during the initial access latency time (before data is output) in which case the initial latency time can be reduced to zero, or after the device has output data. When the Synchronous Burst Read operation is suspended, internal array sensing continues and any previously latched internal data is retained. A burst sequence can be suspended and resumed as often as required as long as the operating conditions of the device are met. A Synchronous Burst Read operation is suspended when E is low and the current address has been latched (on a Latch Enable rising edge or on a valid clock edge). The clock signal is then halted at VIH or at VIL, and G goes high. When G becomes low again and the clock signal restarts, the Synchronous Burst Read operation is resumed exactly where it stopped. WAIT being gated by E remains active and will not revert to high-impedance when G goes high. So if two or more devices are connected to the system’s READY signal, to prevent bus contention the WAIT signal of the Flash memory should not be directly connected to the system’s READY signal. See Table 22: Synchronous Read AC characteristics and Figure 14: Synchronous Burst Read Suspend AC waveforms, for details. 9.3 Single Synchronous Read mode Single Synchronous Read operations are similar to Synchronous Burst Read operations except that only the first data output after the X latency is valid. Synchronous Single Reads are used to read the Electronic Signature, Status Register, CFI, Block Protection Status, Configuration Register Status or Protection Register. When the addressed bank is in Read CFI, Read Status Register or Read Electronic Signature mode, the WAIT signal is always asserted. See Table 22: Synchronous Read AC characteristics and Figure 13: Single Synchronous Read AC waveforms, for details. 48/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 10 Dual operations and Multiple Bank Dual operations and Multiple Bank architecture The Multiple Bank Architecture of the M58WRxxxQT/B provides flexibility for software developers by allowing code and data to be split with 4Mbit granularity. The Dual Operations feature simplifies the software management of the device and allows code to be executed from one bank while another bank is being programmed or erased. The Dual operations feature means that while programming or erasing in one bank, Read operations are possible in another bank with zero latency (only one bank at a time is allowed to be in Program or Erase mode). If a Read operation is required in a bank which is programming or erasing, the Program or Erase operation can be suspended. Also if the suspended operation was Erase then a Program command can be issued to another block, so the device can have one block in Erase Suspend mode, one programming and other banks in Read mode. Bus Read operations are allowed in another bank between setup and confirm cycles of program or erase operations. The combination of these features means that read operations are possible at any moment. Tables 12 and 13 show the dual operations possible in other banks and in the same bank. For a complete list of possible commands refer to Appendix D: Command interface state tables. Table 12. Dual operations allowed in other banks Commands allowed in another bank Status of bank Read Array Read Read Status CFI Register Query Read Electronic Program Signature Block Erase Program/ Program/ Erase Erase Suspend Resume Idle Yes Yes Yes Yes Yes Yes Yes Yes Programming Yes Yes Yes Yes – – Yes – Erasing Yes Yes Yes Yes – – Yes – Program Suspended Yes Yes Yes Yes – – – Yes Erase Suspended Yes Yes Yes Yes Yes – – Yes 49/110 Dual operations and Multiple Bank architecture Table 13. M58WR016QT, M58WR016QB, M58WR032QT, Dual operations allowed in same bank Commands allowed in same bank Status of bank Idle Programming Erasing Read Array Read Read Read Block Status CFI Electronic Program Erase Register Query Signature Program/ Program/ Erase Erase Suspend Resume Yes Yes Yes Yes Yes Yes Yes Yes (1) Yes Yes Yes – – Yes – (1) Yes Yes Yes – – Yes – – – Program Suspended Yes(2) Yes Yes Yes – – – Yes Erase Suspended Yes(2) Yes Yes Yes Yes(2) – – Yes 1. The Read Array command is accepted but the data output is not guaranteed until the Program or Erase has completed. 2. Not allowed in the Block or Word that is being erased or programmed. 50/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 11 Block locking Block locking The M58WRxxxQT/B features an instant, individual block locking scheme that allows any block to be locked or unlocked with no latency. This locking scheme has three levels of protection. ● Lock/Unlock - this first level allows software-only control of block locking. ● Lock-Down - this second level requires hardware interaction before locking can be changed. ● VPP ≤VPPLK - the third level offers a complete hardware protection against program and erase on all blocks. The protection status of each block can be set to Locked, Unlocked, and Lock-Down. Table 14, defines all of the possible protection states (WP, DQ1, DQ0), and Appendix C, Figure 26, shows a flowchart for the locking operations. 11.1 Reading a Block’s lock status The lock status of every block can be read in the Read Electronic Signature mode of the device. To enter this mode write 90h to the device. Subsequent reads at the address specified in Table 7, will output the protection status of that block. The lock status is represented by DQ0 and DQ1. DQ0 indicates the Block Lock/Unlock status and is set by the Lock command and cleared by the Unlock command. It is also automatically set when entering Lock-Down. DQ1 indicates the Lock-Down status and is set by the Lock-Down command. It cannot be cleared by software, only by a hardware reset or power-down. The following sections explain the operation of the locking system. 11.2 Locked state The default status of all blocks on power-up or after a hardware reset is Locked (states (0,0,1) or (1,0,1)). Locked blocks are fully protected from any program or erase. Any program or erase operations attempted on a locked block will return an error in the Status Register. The Status of a Locked block can be changed to Unlocked or Lock-Down using the appropriate software commands. An Unlocked block can be Locked by issuing the Lock command. 11.3 Unlocked state Unlocked blocks (states (0,0,0), (1,0,0) (1,1,0)), can be programmed or erased. All unlocked blocks return to the Locked state after a hardware reset or when the device is powereddown. The status of an unlocked block can be changed to Locked or Locked-Down using the appropriate software commands. A locked block can be unlocked by issuing the Unlock command. 51/110 Block locking 11.4 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Lock-Down state Blocks that are Locked-Down (state (0,1,x))are protected from program and erase operations (as for Locked blocks) but their protection status cannot be changed using software commands alone. A Locked or Unlocked block can be Locked-Down by issuing the Lock-Down command. Locked-Down blocks revert to the Locked state when the device is reset or powered-down. The Lock-Down function is dependent on the WP input pin. When WP=0 (VIL), the blocks in the Lock-Down state (0,1,x) are protected from program, erase and protection status changes. When WP=1 (VIH) the Lock-Down function is disabled (1,1,x) and Locked-Down blocks can be individually unlocked to the (1,1,0) state by issuing the software command, where they can be erased and programmed. These blocks can then be re-locked (1,1,1) and unlocked (1,1,0) as desired while WP remains high. When WP is Low, blocks that were previously Locked-Down return to the Lock-Down state (0,1,x) regardless of any changes made while WP was high. Device reset or power-down resets all blocks, including those in Lock-Down, to the Locked state. 11.5 Locking operations during Erase Suspend Changes to block lock status can be performed during an erase suspend by using the standard locking command sequences to unlock, lock or lock-down a block. This is useful in the case when another block needs to be updated while an erase operation is in progress. To change block locking during an erase operation, first write the Erase Suspend command, then check the status register until it indicates that the erase operation has been suspended. Next write the desired Lock command sequence to a block and the lock status will be changed. After completing any desired lock, read, or program operations, resume the erase operation with the Erase Resume command. If a block is locked or locked-down during an erase suspend of the same block, the locking status bits will be changed immediately, but when the erase is resumed, the erase operation will complete. Locking operations cannot be performed during a program suspend. Refer to Appendix Appendix D: Command interface state tables, for detailed information on which commands are valid during erase suspend. 52/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 14. Block locking Lock status Current Protection Status(1) (WP, DQ1, DQ0) Next Protection Status(1) (WP, DQ1, DQ0) Current State Program/Erase Allowed After Block Lock Command After Block Unlock Command After Block Lock-Down Command After WP transition 1,0,0 yes 1,0,1 1,0,0 1,1,1 0,0,0 1,0,1(2) no 1,0,1 1,0,0 1,1,1 0,0,1 1,1,0 yes 1,1,1 1,1,0 1,1,1 0,1,1 1,1,1 no 1,1,1 1,1,0 1,1,1 0,1,1 0,0,0 yes 0,0,1 0,0,0 0,1,1 1,0,0 0,0,1(2) no 0,0,1 0,0,0 0,1,1 1,0,1 0,1,1 no 0,1,1 0,1,1 0,1,1 1,1,1 or 1,1,0(3) 1. The lock status is defined by the write protect pin and by DQ1 (‘1’ for a locked-down block) and DQ0 (‘1’ for a locked block) as read in the Read Electronic Signature command with A1 = VIH and A0 = VIL. 2. All blocks are locked at power-up, so the default configuration is 001 or 101 according to WP status. 3. A WP transition to VIH on a locked block will restore the previous DQ0 value, giving a 111 or 110. 53/110 Program and erase times and endurance cycles 12 M58WR016QT, M58WR016QB, M58WR032QT, Program and erase times and endurance cycles The Program and Erase times and the number of Program/ Erase cycles per block are shown in Table 15. Exact erase times may change depending on the memory array condition. The best case is when all the bits in the block or bank are at ‘0’ (preprogrammed). The worst case is when all the bits in the block or bank are at ‘1’ (not preprogrammed). Usually, the system overhead is negligible with respect to the erase time. In the M58WRxxxQT/B the maximum number of Program/ Erase cycles depends on the VPP voltage supply used. Table 15. Program/Erase times and endurance cycles(1) Parameter Condition Min Parameter Block (4 KWord)(2) Erase Main Block (32 KWord) Typical after 100k Typ Max W/E Cycles Unit 0.3 1 2.5 s Preprogrammed 0.8 3 4 s Not Preprogrammed 1.1 4 s Preprogrammed 3 s 4.5 s Bank (4Mbit) VPP = VDD Not Preprogrammed Program(3) Suspend Latency Word 10 Parameter Block (4 KWord) 32 ms Main Block (32 KWord) 256 ms 100 µs Program 5 10 µs Erase 5 20 µs Program/Erase Main Blocks Cycles (per Parameter Blocks Block) 54/110 10 100,000 cycles 100,000 cycles M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Program and erase times and endurProgram/Erase times and endurance cycles(1) (continued) Table 15. Parameter Erase Min Unit Parameter Block (4 KWord) 0.25 2.5 s Main Block (32 KWord) 0.8 4 s Bank (4Mbit) 3.5 s Word/ Double Word/ Quadruple Word(4) 8 Quad-Enhanced Factory 10 ms Enhanced Factory 25 ms Quadruple Word(4) 8 ms Word 32 ms Quad-Enhanced Factory 80 ms Enhanced Factory 200 ms Word(4) 64 ms 256 ms 520 s 510 ms Parameter Block (4 KWord) VPP = VPPH Condition Typical after 100k Typ Max W/E Cycles (3) Program Main Block (32 KWord) Quadruple Word Quad-Enhanced (4) Bank (4Mbit) Factory Quadruple Word(4) Program/Erase Main Blocks Cycles (per Parameter Blocks Block) 100 µs 1000 cycles 2500 cycles 1. TA = –40 to 85°C; VDD = 1.7V to 2.2V; VDDQ = 2.2V to 3.3V. 2. The difference between Preprogrammed and not preprogrammed is not significant (‹30ms). 3. Values are liable to change with the external system-level overhead (command sequence and Status Register polling execution). 4. Measurements performed at 25°C. TA = 25°C ±5°C for Quadruple Word, Double Word and Quadruple Enhanced Factory Program. 55/110 Maximum rating 13 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Maximum rating Stressing the device above the rating listed in the Absolute Maximum Ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Refer also to the Numonyx SURE Program and other relevant quality documents. Table 16. Absolute maximum ratings Value Symbol Unit Min Max Ambient Operating Temperature –40 85 °C TBIAS Temperature Under Bias –40 125 °C TSTG Storage Temperature –65 155 °C VIO Input or Output Voltage –0.5 VDDQ+0.6 V VDD Supply Voltage –0.2 2.45 V Input/Output Supply Voltage –0.2 2.45 V Program Voltage –0.2 14 V Output Short Circuit Current 100 mA Time for VPP at VPPH 100 hours TA VDDQ VPP IO tVPPH 56/110 Parameter M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 14 DC and AC parameters DC and AC parameters This section summarizes the operating measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC and AC characteristics Tables that follow, are derived from tests performed under the Measurement Conditions summarized in Table 17: Operating and AC measurement conditions. Designers should check that the operating conditions in their circuit match the operating conditions when relying on the quoted parameters. Table 17. Operating and AC measurement conditions M58WRxxxQT/B Parameter 60 70 80 Unit Min Max Min Max Min Max VDD Supply Voltage 1.7 2 1.7 2 1.7 2 V VDDQ Supply Voltage 1.7 2.24 1.7 2.24 1.7 2.24 V VPP Supply Voltage (Factory environment) 11.4 12.6 11.4 12.6 11.4 12.6 V VPP Supply Voltage (Application environment) –0.4 VDDQ+0.4 –0.4 VDDQ+0.4 –0.4 VDDQ+0.4 V Ambient Operating Temperature –40 85 –40 85 –40 85 °C Load Capacitance (CL) 30 Input Rise and Fall Times Input Pulse Voltages Input and Output Timing Ref. Voltages Figure 8. 30 30 pF 5 5 5 ns 0 to VDDQ 0 to VDDQ 0 to VDDQ V VDDQ/2 VDDQ/2 VDDQ/2 V AC measurement I/O waveform VDDQ VDDQ/2 0V AI06161 57/110 DC and AC parameters Figure 9. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB AC measurement load circuit VDDQ VDDQ VDD 16.7kΩ DEVICE UNDER TEST CL 0.1µF 16.7kΩ 0.1µF CL includes JIG capacitance Table 18. Symbol CIN COUT Capacitance(1) Parameter Input Capacitance Output Capacitance 1. Sampled only, not 100% tested. 58/110 AI06162 Test Condition Min Max Unit VIN = 0V 6 8 pF VOUT = 0V 8 12 pF M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 19. Symbol DC and AC parameters DC characteristics - currents Parameter Test Condition Min Typ Max Unit 0V ≤VIN ≤VDDQ ±1 µA ±1 µA ILI Input Leakage Current ILO Output Leakage Current 0V ≤VOUT ≤VDDQ Supply Current Asynchronous Read (f=6MHz) E = VIL, G = VIH 3 6 mA 4 Word 7 16 mA 8 Word 10 18 mA 16 Word 12 22 mA Continuous 13 25 mA 4 Word 8 17 mA 8 Word 11 20 mA 16 Word 14 25 mA Continuous 16 30 mA Supply Current Synchronous Read (f=54MHz) IDD1 Supply Current Synchronous Read (f=66MHz) IDD2 Supply Current (Reset) RP = VSS ± 0.2V 10 50 µA IDD3 Supply Current (Standby) E = VDDQ ± 0.2V K = VSS 10 50 µA IDD4 Supply Current (Automatic Standby) E = VIL, G = VIH 10 50 µA VPP = VPPH 8 15 mA VPP = VDD 10 20 mA VPP = VPPH 8 15 mA VPP = VDD 10 20 mA Program/Erase in one Bank, Asynchronous Read in another Bank 13 26 mA Program/Erase in one Bank, Synchronous Read in another Bank 23 45 mA E = VDDQ ± 0.2V K = VSS 10 50 µA VPP = VPPH 2 5 mA VPP = VDD 0.2 5 µA VPP = VPPH 2 5 mA VPP = VDD 0.2 5 µA VPP Supply Current (Read) VPP ≤VDD 0.2 5 µA VPP Supply Current (Standby) VPP ≤VDD 0.2 5 µA Supply Current (Program) IDD5(1) Supply Current (Erase) IDD6(1)(2) IDD7(1) Supply Current (Dual Operations) Supply Current Program/ Erase Suspended (Standby) VPP Supply Current (Program) IPP1(1) VPP Supply Current (Erase) IPP2 IPP3 (1) 1. Sampled only, not 100% tested. 2. VDD Dual Operation current is the sum of read and program or erase currents. 59/110 DC and AC parameters Table 20. Symbol 60/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB DC characteristics - voltages Parameter Test Condition Min Typ Max Unit VIL Input Low Voltage –0.5 0.4 V VIH Input High Voltage VDDQ –0.4 VDDQ + 0.4 V VOL Output Low Voltage IOL = 100µA 0.1 V VOH Output High Voltage IOH = –100µA VDDQ –0.1 VPP1 VPP Program VoltageLogic Program, Erase 1.3 1.8 3.3 V VPPH VPP Program Voltage Factory Program, Erase 11.4 12 12.6 V VPPLK Program or Erase Lockout 0.4 V VLKO VDD Lock Voltage 1 V VRPH RP pin Extended High Voltage 3.3 V V M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB DC and AC parameters Figure 10. Asynchronous Random Access Read AC waveforms A0-Amax(2) VALID VALID tAVAV tAVLH tAXQX tLHAX L tLLLH tLLQV tLHGL tELLH tELQV E tEHQZ tELQX tEHQX G tGHQX tGLQV tGHQZ tGLQX Hi-Z tEHTZ tELTV WAIT tAVQV DQ0-DQ15 Hi-Z VALID Valid Address Latch Outputs Enabled Data Valid Notes: 1. Write Enable, W, is High, WAIT is active Low. 2. Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. Standby AI10178 61/110 62/110 (1) DQ0-DQ15 WAIT G E L A0-A1 Hi-Z tELTV tELQX tGLQV tGLQX tELQV Valid Address Latch tELLH tLLQV tLLLH tAVLH VALID ADDRESS tAVAV Enabled Outputs tLHGL tLHAX VALID DATA Valid Data VALID DATA VALID ADDRESS VALID DATA tAVQV1 VALID ADDRESS VALID ADDRESS Note 1. WAIT is active Low. 2. Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. A2-Amax(2) VALID DATA VALID ADDRESS AI10179 Standby DC and AC parameters M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 11. Asynchronous Page Read AC waveforms M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 21. DC and AC parameters Asynchronous Read AC characteristics M58WRxxxQT/B Symbol Alt Read Timings Unit 60 70 80 tAVAV tRC Address Valid to Next Address Valid Min 60 70 80 ns tAVQV tACC Address Valid to Output Valid (Random) Max 60 70 80 ns tAVQV1 tPAGE Address Valid to Output Valid (Page) Max 20 20 25 ns tAXQX(1) tOH Address Transition to Output Transition Min 0 0 0 ns Chip Enable Low to Wait Valid Max 11 14 14 ns tELTV Latch Timings Parameter tELQV (2) tCE Chip Enable Low to Output Valid Max 60 70 80 ns tELQX (1) tLZ Chip Enable Low to Output Transition Min 0 0 0 ns Chip Enable High to Wait Hi-Z Max 14 17 17 ns tEHTZ (1) tOH Chip Enable High to Output Transition Min 0 0 0 ns tEHQZ(1) tHZ Chip Enable High to Output Hi-Z Max 14 17 17 ns tGLQV(2) tOE Output Enable Low to Output Valid Max 20 20 25 ns tGLQX(1) tOLZ Output Enable Low to Output Transition Min 0 0 0 ns tGHQX(1) tOH Output Enable High to Output Transition Min 0 0 0 ns tGHQZ(1) tDF Output Enable High to Output Hi-Z Max 14 14 14 ns tAVLH tAVADVH Address Valid to Latch Enable High Min 7 9 9 ns tELLH tELADVH Chip Enable Low to Latch Enable High Min 10 10 10 ns tLHAX tADVHAX Latch Enable High to Address Transition Min 7 9 9 ns Min 7 9 9 ns tEHQX tLLLH tADVLADVH Latch Enable Pulse Width tLLQV tADVLQV Latch Enable Low to Output Valid (Random) Max 60 70 80 ns tLHGL tADVHGL Latch Enable High to Output Enable Low Min 0 0 0 ns 1. Sampled only, not 100% tested. 2. G may be delayed by up to tELQV - tGLQV after the falling edge of E without increasing tELQV. 63/110 64/110 Hi-Z tELKH Hi-Z tLLLH Address Latch tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS X Latency tGLQX Note 2 tKHTV Note 1 VALID Valid Data Flow tKHQV VALID Note 2 tKHTX tKHQX VALID Boundary Crossing Note 2 NOT VALID Data Valid tGHQZ Standby AI10180 tEHTZ tEHQZ tEHQX tEHEL VALID tGHQX Notes 1. The number of clock cycles to be inserted depends on the X latency set in the Burst Configuration Register. 2. The WAIT signal can be configured to be active during wait state or one cycle before. WAIT signal is active Low. 3. Address latched and data output on the rising clock edge. Either the falling or the rising edge of the clock signal, K, can be configured as the active edge. Here the active edge of K is the rising one. 4. Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. WAIT G E K(3) L A0-Amax(3) DQ0-DQ15 DC and AC parameters M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 12. Synchronous Burst Read AC waveforms Hi-Z tELKH Hi-Z tLLLH tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS tGLQV tGLQX Note 1 Note 3 tKHTV tKHQV VALID NOT VALID NOT VALID NOT VALID tGHQZ tGHQX tEHEL tEHQZ AI10181 tEHTZ NOT VALID tEHQX NOT VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Burst Configuration Register. 2. The WAIT signal is configured to be active during wait state. WAIT signal is active Low. 3. WAIT is always asserted when addressed bank is in Read CFI, Read SR or Read electronic signature mode. WAIT signals valid data if the addressed bank is in Read Array mode. 4. Address latched and data output on the rising clock edge. Either the falling or the rising edge of the clock signal, K, can be configured as the active edge. Here the active edge of K is the rising one. 5. Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. WAIT(2) G E K(4) L A0-Amax(5) DQ0-DQ15 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB DC and AC parameters Figure 13. Single Synchronous Read AC waveforms 65/110 66/110 tELKH tLLLH tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS tGLQV tGLQX Note 1 tKHQV VALID VALID tGHQZ Note 3 tGHQX tEHEL tEHQZ AI10182 tEHTZ NOT VALID tEHQX NOT VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register. 2. The WAIT signal is configured to be active during wait state. WAIT signal is active Low. 3. The CLOCK signal can be held high or low 4. Address latched and data output on the rising clock edge. Either the rising or the falling edge of the clock signal, K, can be configured as the active edge. Here, the active edge is the rising one. 5. Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. WAIT(2) G E K(4) L Hi-Z Hi-Z A0-Amax(5) DQ0-DQ15 DC and AC parameters M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 14. Synchronous Burst Read Suspend AC waveforms M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB DC and AC parameters Figure 15. Clock input AC waveform tKHKL tKHKH tr tf tKLKH AI06981 Table 22. Synchronous Read AC characteristics(1) (2) M58WRxxxQT/B Synchronous Read Timings Symbol Parameter Unit 60 70 80 tAVKH tAVCLKH Address Valid to Clock High Min 7 9 9 ns tELKH tELCLKH Chip Enable Low to Clock High Min 7 9 9 ns tELTV Chip Enable Low to Wait Valid Max 11 14 14 ns tEHEL Chip Enable Pulse Width (subsequent synchronous reads) Min 14 14 14 ns tEHTZ Chip Enable High to Wait Hi-Z Max 11 14 14 ns tKHAX tCLKHAX Clock High to Address Transition Min 7 9 9 ns tKHQV tKHTV tCLKHQV Clock High to Output Valid Clock High to WAIT Valid Max 11 14 14 ns tKHQX tKHTX tCLKHQX Clock High to Output Transition Clock High to WAIT Transition Min 3 4 4 ns Min 7 9 9 ns 18.5 18.5 ns tLLKH Clock Specifications Alt tADVLCLKH Latch Enable Low to Clock High Clock Period (f=54MHz) Min Clock Period (f=66MHz) Min 15 tKHKL tKLKH Clock High to Clock Low Clock Low to Clock High Min 3.5 4.5 4.5 ns tf tr Clock Fall or Rise Time Max 3 3 3 ns tKHKH tCLK ns 1. Sampled only, not 100% tested. 2. For other timings please refer to Table 21: Asynchronous Read AC characteristics. 67/110 68/110 tWHDX CONFIRM COMMAND OR DATA INPUT tVPHWH tWHVPL tWHWPL tQVVPL tQVWPL STATUS REGISTER STATUS REGISTER READ 1st POLLING tELQV VALID ADDRESS PROGRAM OR ERASE tELKV tWHEL tWHGL tWHAV tWHAX CMD or DATA VALID ADDRESS tAVWH tWPHWH tWHWL tWHEH tWHLL tWLWH tLHAX COMMAND tLLLH SET-UP COMMAND tDVWH tGHWL tELWL tELLH tAVLH BANK ADDRESS Note: Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. K VPP WP DQ0-DQ15 W G E L A0-Amax tAVAV AI10183b DC and AC parameters M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 16. Write AC waveforms, Write Enable controlled M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB DC and AC parameters Write AC characteristics, Write Enable controlled(1) Table 23. M58WRxxxQT/B Symbol Alt tAVAV 80 60 70 80 ns tAVLH Address Valid to Latch Enable High Min 7 9 9 ns tAVWH(2) Address Valid to Write Enable High Min 40 45 50 ns Data Valid to Write Enable High Min 40 45 50 ns Chip Enable Low to Latch Enable High Min 10 10 10 ns Chip Enable Low to Write Enable Low Min 0 0 0 ns tELQV Chip Enable Low to Output Valid Min 60 70 80 ns tELKV Chip Enable Low to Clock Valid Min 7 9 9 ns tGHWL Output Enable High to Write Enable Low Min 14 17 17 ns tLHAX Latch Enable High to Address Transition Min 7 9 9 ns tLLLH Latch Enable Pulse Width Min 7 9 9 ns Write Enable High to Address Valid Min 0 0 0 ns tAH Write Enable High to Address Transition Min 0 0 0 ns tWHDX tDH Write Enable High to Input Transition Min 0 0 0 ns tWHEH tCH Write Enable High to Chip Enable High Min 0 0 0 ns Write Enable High to Chip Enable Low Min 20 25 25 ns tWHGL Write Enable High to Output Enable Low Min 0 0 0 ns tWHLL Write Enable High to Latch Enable Low Min 0 0 0 ns tWHWL tWPH Write Enable High to Write Enable Low Min 20 25 25 ns tWLWH tWP Write Enable Low to Write Enable High Min 40 45 50 ns tQVVPL Output (Status Register) Valid to VPP Low Min 0 0 0 ns tQVWPL Output (Status Register) Valid to Write Protect Low Min 0 0 0 ns tELWL Write Enable Controlled Timings 70 Min tDS tELLH tCS tWHAV(2) tWHAX (2) tWHEL(3) Protection Timings Unit 60 Address Valid to Next Address Valid tDVWH tWC Parameter tVPHWH tVPS VPP High to Write Enable High Min 200 200 200 ns tWHVPL Write Enable High to VPP Low Min 200 200 200 ns tWHWPL Write Enable High to Write Protect Low Min 200 200 200 ns tWPHWH Write Protect High to Write Enable High Min 200 200 200 ns 1. Sampled only, not 100% tested. 2. Meaningful only if L is always kept low. 3. tWHEL has this value when reading from the targeted bank or when reading from any address after a Set Configuration Register command has been issued. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing any command, or to delay the first read to any address after issuing a Set Configuration Register command. If the first read after the command is a Read Array operation in a different bank and no changes to the Configuration Register have been issued, tWHEL is 0ns. 69/110 70/110 tELEH tLHAX COMMAND SET-UP COMMAND tDVEH tLLLH tELLH tGHEL tWLEL tAVLH BANK ADDRESS tEHDX tEHEL tEHWH CMD or DATA tEHAX CONFIRM COMMAND OR DATA INPUT tVPHEH tWPHEH tAVEH VALID ADDRESS Note: Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. K VPP WP DQ0-DQ15 E G W L A0-Amax tAVAV tEHVPL tEHWPL tELKV tWHEL tEHGL tQVVPL tQVWPL STATUS REGISTER STATUS REGISTER READ 1st POLLING tELQV VALID ADDRESS PROGRAM OR ERASE AI10184b DC and AC parameters M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 17. Write AC waveforms, Chip Enable controlled M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 24. DC and AC parameters Write AC characteristics, Chip Enable controlled(1) M58WRxxxQT/B Symbol Chip Enable Controlled Timings tAVAV Alt tWC Unit 60 70 80 Address Valid to Next Address Valid Min 60 70 80 ns tAVEH Address Valid to Chip Enable High Min 40 45 50 ns tAVLH Address Valid to Latch Enable High Min 7 9 9 ns tDVEH tDS Data Valid to Chip Enable High Min 40 45 50 ns tEHAX tAH Chip Enable High to Address Transition Min 0 0 0 ns tEHDX tDH Chip Enable High to Input Transition Min 0 0 0 ns tEHEL tCPH Chip Enable High to Chip Enable Low Min 20 25 25 ns Chip Enable High to Output Enable Low Min 0 0 0 ns Chip Enable High to Write Enable High Min 0 0 0 ns Chip Enable Low to Clock Valid Min 7 9 9 ns Chip Enable Low to Chip Enable High Min 40 45 50 ns tELLH Chip Enable Low to Latch Enable High Min 10 10 10 ns tELQV Chip Enable Low to Output Valid Min 60 70 80 ns tGHEL Output Enable High to Chip Enable Low Min 14 17 17 ns tLHAX Latch Enable High to Address Transition Min 7 9 9 ns tLLLH Latch Enable Pulse Width Min 7 9 9 ns Write Enable High to Chip Enable Low Min 20 25 25 ns Write Enable Low to Chip Enable Low Min 0 0 0 ns tEHVPL Chip Enable High to VPP Low Min 200 200 200 ns tEHWPL Chip Enable High to Write Protect Low Min 200 200 200 ns tQVVPL Output (Status Register) Valid to VPP Low Min 0 0 0 ns tQVWPL Output (Status Register) Valid to Write Protect Low Min 0 0 0 ns Min 200 200 200 ns Min 200 200 200 ns tEHGL tEHWH tCH tELKV tELEH tCP tWHEL(2) tWLEL Protection Timings Parameter tVPHEH tWPHEH tCS tVPS VPP High to Chip Enable High Write Protect High to Chip Enable High 1. Sampled only, not 100% tested. 2. tWHEL has this value when reading from the targeted bank or when reading from any address after a Set Configuration Register command has been issued. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing any command, or to delay the first read to any address after issuing a Set Configuration Register command. If the first read after the command is a Read Array operation in a different bank and no changes to the Configuration Register have been issued, tWHEL is 0ns. 71/110 DC and AC parameters M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 18. Reset and Power-up AC waveforms tPHWL tPHEL tPHGL tPHLL W, E, G, L tPLWL tPLEL tPLGL tPLLL RP tVDHPH tPLPH VDD, VDDQ Power-Up Reset AI06976 Table 25. Symbol Reset and Power-up AC characteristics Parameter tPLWL tPLEL tPLGL tPLLL Reset Low to Write Enable Low, Chip Enable Low, Output Enable Low, Latch Enable Low tPHWL tPHEL tPHGL tPHLL tPLPH(1),(2) tVDHPH(3) Test Condition 60 70 80 Unit During Program Min 10 10 10 µs During Erase Min 20 20 20 µs Other Conditions Min 80 80 80 ns Reset High to Write Enable Low Chip Enable Low Output Enable Low Latch Enable Low Min 30 30 30 ns RP Pulse Width Min 50 50 50 ns Supply Voltages High to Reset High Min 50 50 50 µs 1. The device Reset is possible but not guaranteed if tPLPH < 50ns. 2. Sampled only, not 100% tested. 3. It is important to assert RP in order to allow proper CPU initialization during Power-Up or Reset. 72/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 15 Package mechanical Package mechanical Figure 19. VFBGA56 - 7.7x9mm, 8x7 ball array, 0.75mm pitch, Bottom View Package Outline D D1 FD FE E SD E1 ddd BALL "A1" e e b A A2 A1 BGA-Z38 1. Drawing is not to scale. Table 26. VFBGA56 - 7.7x9mm, 8x7 ball array, 0.75mm pitch, package mechanical data millimeters inches Symbol Typ Min A Max Typ Min 1.000 A1 Max 0.0394 0.200 0.0079 A2 0.660 0.0260 b 0.350 0.300 0.400 0.0138 0.0118 0.0157 D 7.700 7.600 7.800 0.3031 0.2992 0.3071 D1 5.250 – – 0.2067 – – ddd 0.080 0.0031 e 0.750 – – 0.0295 – – E 9.000 8.900 9.100 0.3543 0.3504 0.3583 E1 4.500 – – 0.1772 – – FD 1.225 – – 0.0482 – – FE 2.250 – – 0.0886 – – SD 0.375 – – 0.0148 – – 73/110 Part numbering 16 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Part numbering Table 27. Ordering information scheme Example: Device Type M58 Architecture W = Multiple Bank, Burst Mode Operating Voltage R = VDD = 1.7V to 2V, VDDQ = 1.7V to 2.24V Density 016 = 16 Mbit (x16) 032 = 32 Mbit (x16) Technology Q = 0.11µm technology Parameter Location T = Top Boot B = Bottom Boot Speed 60 = 60ns 70 = 70ns 80 = 80ns Package ZB = VFBGA56, 7.7x9mm, 0.75mm pitch Temperature Range 6 = –40 to 85°C Option Blank = Standard Packing T = Tape & Reel Packing E = ECOPACK® Package, Standard Packing F = ECOPACK® Package, Tape & Reel Packing 74/110 M58WR016QT 70 ZB 6 T M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 28. Part numbering Daisy chain ordering scheme Example: M58WR016QT ZB T Device Type M58WR016Q Daisy Chain ZB = VFBGA56, 7.7x9mm, 0.75mm pitch Option Blank = Standard Packing T = Tape & Reel Packing E = ECOPACK® Package, Standard Packing F = ECOPACK®, Tape & Reel Packing Devices are shipped from the factory with the memory content bits erased to ’1’. For a list of available options (Speed, Package, etc.) or for further information on any aspect of this device, please contact the Numonyx Sales Office nearest to you. 75/110 Block address tables Appendix A Block address tables Table 29. (1) Bank 2 Bank 1 Parameter Bank Bank 76/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Top boot block addresses, M58WR016QT # Size (KWord) Address Range 0 4 FF000-FFFFF 1 4 FE000-FEFFF 2 4 FD000-FDFFF 3 4 FC000-FCFFF 4 4 FB000-FBFFF 5 4 FA000-FAFFF 6 4 F9000-F9FFF 7 4 F8000-F8FFF 8 32 F0000-F7FFF 9 32 E8000-EFFFF 10 32 E0000-E7FFF 11 32 D8000-DFFFF 12 32 D0000-D7FFF 13 32 C8000-CFFFF 14 32 C0000-C7FFF 15 32 B8000-BFFFF 16 32 B0000-B7FFF 17 32 A8000-AFFFF 18 32 A0000-A7FFF 19 32 98000-9FFFF 20 32 90000-97FFF 21 32 88000-8FFFF 22 32 80000-87FFF 23 32 78000-7FFFF 24 32 70000-77FFF 25 32 68000-6FFFF 26 32 60000-67FFF 27 32 58000-5FFFF 28 32 50000-57FFF 29 32 48000-4FFFF 30 32 40000-47FFF M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Bank 3 Table 29. Block address tables Top boot block addresses, M58WR016QT (continued) 31 32 38000-3FFFF 32 32 30000-37FFF 33 32 28000-2FFFF 34 32 20000-27FFF 35 32 18000-1FFFF 36 32 10000-17FFF 37 32 08000-0FFFF 38 32 00000-07FFF 1. There are two Bank Regions: Bank Region 1 contains all the banks that are made up of main blocks only; Bank Region 2 contains the banks that are made up of the parameter and main blocks (Parameter Bank). Table 30. Bank 1 Bank 2 Bank 3 Bank(1) Bottom boot block addresses, M58WR016QB # Size (KWord) Address Range 38 32 F8000-FFFFF 37 32 F0000-F7FFF 36 32 E8000-EFFFF 35 32 E0000-E7FFF 34 32 D8000-DFFFF 33 32 D0000-D7FFF 32 32 C8000-CFFFF 31 32 C0000-C7FFF 30 32 B8000-BFFFF 29 32 B0000-B7FFF 28 32 A8000-AFFFF 27 32 A0000-A7FFF 26 32 98000-9FFFF 25 32 90000-97FFF 24 32 88000-8FFFF 23 32 80000-87FFF 22 32 78000-7FFFF 21 32 70000-77FFF 20 32 68000-6FFFF 19 32 60000-67FFF 18 32 58000-5FFFF 17 32 50000-57FFF 16 32 48000-4FFFF 15 32 40000-47FFF 77/110 Block address tables Parameter Bank Table 30. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Bottom boot block addresses, M58WR016QB (continued) 14 32 38000-3FFFF 13 32 30000-37FFF 12 32 28000-2FFFF 11 32 20000-27FFF 10 32 18000-1FFFF 9 32 10000-17FFF 8 32 08000-0FFFF 7 4 07000-07FFF 6 4 06000-06FFF 5 4 05000-05FFF 4 4 04000-04FFF 3 4 03000-03FFF 2 4 02000-02FFF 1 4 01000-01FFF 0 4 00000-00FFF 1. There are two Bank Regions: Bank Region 2 contains all the banks that are made up of main blocks only; Bank Region 1 contains the banks that are made up of the parameter and main blocks (Parameter Bank). Table 31. Parameter Bank Bank(1) 78/110 Top boot block addresses, M58WR032QT # Size (KWord) Address Range 0 4 1FF000-1FFFFF 1 4 1FE000-1FEFFF 2 4 1FD000-1FDFFF 3 4 1FC000-1FCFFF 4 4 1FB000-1FBFFF 5 4 1FA000-1FAFFF 6 4 1F9000-1F9FFF 7 4 1F8000-1F8FFF 8 32 1F0000-1F7FFF 9 32 1E8000-1EFFFF 10 32 1E0000-1E7FFF 11 32 1D8000-1DFFFF 12 32 1D0000-1D7FFF 13 32 1C8000-1CFFFF 14 32 1C0000-1C7FFF M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Bank 4 Bank 3 Bank 2 Bank 1 Table 31. Block address tables Top boot block addresses, M58WR032QT (continued) 15 32 1B8000-1BFFFF 16 32 1B0000-1B7FFF 17 32 1A8000-1AFFFF 18 32 1A0000-1A7FFF 19 32 198000-19FFFF 20 32 190000-197FFF 21 32 188000-18FFFF 22 32 180000-187FFF 23 32 178000-17FFFF 24 32 170000-177FFF 25 32 168000-16FFFF 26 32 160000-167FFF 27 32 158000-15FFFF 28 32 150000-157FFF 29 32 148000-14FFFF 30 32 140000-147FFF 31 32 138000-13FFFF 32 32 130000-137FFF 33 32 128000-12FFFF 34 32 120000-127FFF 35 32 118000-11FFFF 36 32 110000-117FFF 37 32 108000-10FFFF 38 32 100000-107FFF 39 32 0F8000-0FFFFF 40 32 0F0000-0F7FFF 41 32 0E8000-0EFFFF 42 32 0E0000-0E7FFF 43 32 0D8000-0DFFFF 44 32 0D0000-0D7FFF 45 32 0C8000-0CFFFF 46 32 0C0000-0C7FFF 79/110 Block address tables Bank 7 Bank 6 Bank 5 Table 31. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Top boot block addresses, M58WR032QT (continued) 47 32 0B8000-0BFFFF 48 32 0B0000-0B7FFF 49 32 0A8000-0AFFFF 50 32 0A0000-0A7FFF 51 32 098000-09FFFF 52 32 090000-097FFF 53 32 088000-08FFFF 54 32 080000-087FFF 55 32 078000-07FFFF 56 32 070000-077FFF 57 32 068000-06FFFF 58 32 060000-067FFF 59 32 058000-05FFFF 60 32 050000-057FFF 61 32 048000-04FFFF 62 32 040000-047FFF 63 32 038000-03FFFF 64 32 030000-037FFF 65 32 028000-02FFFF 66 32 020000-027FFF 67 32 018000-01FFFF 68 32 010000-017FFF 69 32 008000-00FFFF 70 32 000000-007FFF 1. There are two Bank Regions: Bank Region 1 contains all the banks that are made up of main blocks only; Bank Region 2 contains the banks that are made up of the parameter and main blocks (Parameter Bank). Table 32. Bank 7 Bank(1) 80/110 Bottom boot block addresses, M58WR032QB # Size (KWord) Address Range 70 32 1F8000-1FFFFF 69 32 1F0000-1F7FFF 68 32 1E8000-1EFFFF 67 32 1E0000-1E7FFF 66 32 1D8000-1DFFFF 65 32 1D0000-1D7FFF 64 32 1C8000-1CFFFF 63 32 1C0000-1C7FFF M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Bank 3 Bank 4 Bank 5 Bank 6 Table 32. Block address tables Bottom boot block addresses, M58WR032QB (continued) 62 32 1B8000-1BFFFF 61 32 1B0000-1B7FFF 60 32 1A8000-1AFFFF 59 32 1A0000-1A7FFF 58 32 198000-19FFFF 57 32 190000-197FFF 56 32 188000-18FFFF 55 32 180000-187FFF 54 32 178000-17FFFF 53 32 170000-177FFF 52 32 168000-16FFFF 51 32 160000-167FFF 50 32 158000-15FFFF 49 32 150000-157FFF 48 32 148000-14FFFF 47 32 140000-147FFF 46 32 138000-13FFFF 45 32 130000-137FFF 44 32 128000-12FFFF 43 32 120000-127FFF 42 32 118000-11FFFF 41 32 110000-117FFF 40 32 108000-10FFFF 39 32 100000-107FFF 38 32 0F8000-0FFFFF 37 32 0F0000-0F7FFF 36 32 0E8000-0EFFFF 35 32 0E0000-0E7FFF 34 32 0D8000-0DFFFF 33 32 0D0000-0D7FFF 32 32 0C8000-0CFFFF 31 32 0C0000-0C7FFF 81/110 Block address tables Parameter Bank Bank 1 Bank 2 Table 32. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Bottom boot block addresses, M58WR032QB (continued) 30 32 0B8000-0BFFFF 29 32 0B0000-0B7FFF 28 32 0A8000-0AFFFF 27 32 0A0000-0A7FFF 26 32 098000-09FFFF 25 32 090000-097FFF 24 32 088000-08FFFF 23 32 080000-087FFF 22 32 078000-07FFFF 21 32 070000-077FFF 20 32 068000-06FFFF 19 32 060000-067FFF 18 32 058000-05FFFF 17 32 050000-057FFF 16 32 048000-04FFFF 15 32 040000-047FFF 14 32 038000-03FFFF 13 32 030000-037FFF 12 32 028000-02FFFF 11 32 020000-027FFF 10 32 018000-01FFFF 9 32 010000-017FFF 8 32 008000-00FFFF 7 4 007000-007FFF 6 4 006000-006FFF 5 4 005000-005FFF 4 4 004000-004FFF 3 4 003000-003FFF 2 4 002000-002FFF 1 4 001000-001FFF 0 4 000000-000FFF 1. There are two Bank Regions: Bank Region 2 contains all the banks that are made up of main blocks only; Bank Region 1 contains the banks that are made up of the parameter and main blocks (Parameter Bank). 82/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Appendix B Common Flash Interface Common Flash Interface The Common Flash Interface is a JEDEC approved, standardized data structure that can be read from the Flash memory device. It allows a system software to query the device to determine various electrical and timing parameters, density information and functions supported by the memory. The system can interface easily with the device, enabling the software to upgrade itself when necessary. When the Read CFI Query Command is issued the device enters CFI Query mode and the data structure is read from the memory. Tables 33, 34, 35, 36, 37, 38, 39, 40, 41 and 42 show the addresses used to retrieve the data. The Query data is always presented on the lowest order data outputs (DQ0-DQ7), the other outputs (DQ8-DQ15) are set to 0. The CFI data structure also contains a security area where a 64 bit unique security number is written (see Figure 5: Protection Register Memory Map). This area can be accessed only in Read mode by the final user. It is impossible to change the security number after it has been written by Numonyx. Issue a Read Array command to return to Read mode. Table 33. Query structure overview(1) Offset Sub-section Name Description 00h Reserved Reserved for algorithm-specific information 10h CFI Query Identification String Command set ID and algorithm data offset 1Bh System Interface Information Device timing & voltage information 27h Device Geometry Definition Flash device layout P Primary Algorithm-specific Extended Query table Additional information specific to the Primary Algorithm (optional) A Alternate Algorithm-specific Extended Query Additional information specific to the table Alternate Algorithm (optional) 80h Security Code Area Lock Protection Register Unique device Number and User Programmable OTP 1. The Flash memory display the CFI data structure when CFI Query command is issued. In this table are listed the main sub-sections detailed in Tables 34, 35, 36 and 37. Query data is always presented on the lowest order data outputs. 83/110 Common Flash Interface Table 34. CFI Query identification string Offset Sub-section Name 00h 0020h 01h 8812h 8813h 8814h 8815h 02h reserved 03h reserved 04h-0Fh reserved 10h 0051h 11h 0052h 12h 0059h 13h 0003h 14h 0000h 15h 16h 0000h 18h 0000h 1Ah Description Manufacturer Code Value Numonyx Top (M58WR016QT) Bottom (M58WR016QB) Top (M58WR032QT) Bottom (M58WR032QB) Device Code Reserved reserved Reserved "Q" Query Unique ASCII String "QRY" "R" "Y" Primary Algorithm Command Set and Control Interface ID code 16 bit ID code defining a specific algorithm offset = P = 0039h Address for Primary Algorithm extended Query table (see Table 36) 0000h 17h 19h 84/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB p = 39h Alternate Vendor Command Set and Control Interface ID Code second vendor specified algorithm supported NA value = A = 0000h Address for Alternate Algorithm extended Query table 0000h NA M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 35. Common Flash Interface CFI query system interface information Offset Data Description Value 1Bh 0017h VDD Logic Supply Minimum Program/Erase or Write voltage bit 7 to 4BCD value in volts bit 3 to 0BCD value in 100 millivolts 1.7V 1Ch 0020h VDD Logic Supply Maximum Program/Erase or Write voltage bit 7 to 4BCD value in volts bit 3 to 0BCD value in 100 millivolts 2V 1Dh 00B4h VPP [Programming] Supply Minimum Program/Erase voltage bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 millivolts 11.4V 1Eh 00C6h VPP [Programming] Supply Maximum Program/Erase voltage bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 millivolts 12.6V 1Fh 0004h Typical time-out per single byte/word program = 2n µs 16µs n 0000h Typical time-out for multi-Byte program = 2 µs 21h 000Ah Typical time-out per individual block erase = 2n 22h 0000h Typical time-out for full chip erase = 2n ms 20h 23h 24h 0003h 0000h NA ms NA n Maximum time-out for word program = 2 times typical Maximum time-out for multi-Byte program = 1s 2n times typical n 128µs NA 25h 0002h Maximum time-out per individual block erase = 2 times typical 4s 26h 0000h Maximum time-out for chip erase = 2n times typical NA 85/110 Common Flash Interface Table 36. Offset Word Mode M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Device geometry definition Data 0015h(1) 27h (2) Description Device Size = 2n in number of bytes 28h 29h 0001h 0000h Flash Device Interface Code description 2Ah 2Bh 0000h 0000h Maximum number of bytes in multi-byte program or page = 2n 2Ch 0002h Number of identical sized erase block regions within the device bit 7 to 0 = x = number of Erase Block Regions 2 001Eh 0000h M58WR016QT/B Erase Block Region 1 Information Number of identical-size erase blocks = 001Eh+1 31 003Eh 0000h M58WR032QT/B Erase Block Region 1 Information Number of identical-size erase blocks = 003Eh+1 63 2Fh 30h 0000h 0001h Erase Block Region 1 Information Block size in Region 1 = 0100h * 256 byte 31h 32h 0007h 0000h Erase Block Region 2 Information Number of identical-size erase blocks = 0007h+1 33h 34h 0020h 0000h Erase Block Region 2 Information Block size in Region 2 = 0020h * 256 byte TOP DEVICES 2Dh 2Eh 35h 38h BOTTOM DEVICES 2 MBytes 4 MBytes 0016h Reserved for future erase block region information x16 Async. NA 64 KByte 8 8 KByte NA 2Dh 2Eh 0007h 0000h Erase Block Region 1 Information Number of identical-size erase block = 0007h+1 2Fh 30h 0020h 0000h Erase Block Region 1 Information Block size in Region 1 = 0020h * 256 byte 001Eh 0000h M58WR016QT/B Erase Block Region 2 Information Number of identical-size erase block = 001Eh+1 31 003Eh 0000h M58WR032QT/B Erase Block Region 2 Information Number of identical-size erase block = 003Eh+1 63 0000h 0001h Erase Block Region 2 Information Block size in Region 2 = 0100h * 256 byte 31h 32h 33h 34h 35h 38h Reserved for future erase block region information 1. Applies to M58WR016QT/B only. 2. Applies to M58WR032QT/B only. 86/110 Value 8 8 KByte 64 KByte NA M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 37. Common Flash Interface Primary algorithm-specific extended query table Offset Data (P)h = 39h 0050h 0052h Description Value "P" Primary Algorithm extended Query table unique ASCII string “PRI” 0049h "R" "I" (P+3)h = 3Ch 0031h Major version number, ASCII "1" (P+4)h = 3Dh 0033h Minor version number, ASCII "3" (P+5)h = 3Eh 00E6h Extended Query table contents for Primary Algorithm. Address (P+5)h contains less significant byte. 0003h (P+7)h = 40h 0000h (P+8)h = 41h 0000h bit 0Chip Erase supported (1 = Yes, 0 = No) bit 1Erase Suspend supported (1 = Yes, 0 = No) bit 2Program Suspend supported (1 = Yes, 0 = No) bit 3Legacy Lock/Unlock supported (1 = Yes, 0 = No) bit 4Queued Erase supported (1 = Yes, 0 = No) bit 5Instant individual block locking supported (1 = Yes, 0 = No) bit 6Protection bits supported (1 = Yes, 0 = No) bit 7Page mode read supported (1 = Yes, 0 = No) bit 8Synchronous read supported (1 = Yes, 0 = No) bit 9Simultaneous operation supported (1 = Yes, 0 = No) bit 10 to 31Reserved; undefined bits are ‘0’. If bit 31 is ’1’ then another 31 bit field of optional features follows at the end of the bit-30 field. No Yes Yes No No Yes Yes Yes Yes Yes Supported Functions after Suspend Read Array, Read Status Register and CFI Query (P+9)h = 42h 0001h Yes bit 0Program supported after Erase Suspend (1 = Yes, 0 = No) bit 7 to 1Reserved; undefined bits are ‘0’ (P+A)h = 43h 0003h (P+B)h = 44h 0000h Block Protect Status Defines which bits in the Block Status Register section of the Query are implemented. bit 0Block protect Status Register Lock/Unlock bit active(1 = Yes, 0 = No) bit 1Block Lock Status Register Lock-Down bit active (1 = Yes, 0 = No) bit 15 to 2Reserved for future use; undefined bits are ‘0’ Yes Yes VDD Logic Supply Optimum Program/Erase voltage (highest performance) (P+C)h = 45h 0018h 1.8V bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV VPP Supply Optimum Program/Erase voltage (P+D)h = 46h 00C0h bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV 12V 87/110 Common Flash Interface Table 38. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Protection Register Information Offset Data (P+E)h = 47h 0001h (P+F)h = 48h 0080h (P+10)h = 49h 0000h (P+11)h = 4Ah 0003h (P+12)h = 4Bh 0004h Table 39. Description Value Number of protection register fields in JEDEC ID space. 0000h indicates that 256 fields are available. Protection Field 1: Protection Description Bits 0-7 Lower byte of protection register address Bits 8-15 Upper byte of protection register address Bits 16-23 2n bytes in factory pre-programmed region Bits 24-31 2n bytes in user programmable region 1 0080h 8 Bytes 16 Bytes Burst Read information Offset Data Description Value (P+13)h = 4Ch Page-mode read capability bits 0-7’n’ such that 2n HEX value represents the number of 0003h read-page bytes. See offset 28h for device word width to determine page-mode data output width. (P+14)h = 4Dh 0004h (P+15)h = 4Eh Synchronous mode read capability configuration 1 bit 3-7Reserved bit 0-2’n’ such that 2n+1 HEX value represents the maximum number of continuous synchronous reads when the device is configured for its maximum word width. A value of 07h indicates that the device is capable of continuous linear bursts 0001h that will output data until the internal burst counter reaches the end of the device’s burstable address space. This field’s 3-bit value can be written directly to the read configuration register bit 0-2 if the device is configured for its maximum word width. See offset 28h for word width to determine the burst data output width. 4 (P+16)h = 4Fh 0002h Synchronous mode read capability configuration 2 8 (P+17)h = 50h 0003h Synchronous mode read capability configuration 3 16 (P+18)h = 51h 0007h Synchronous mode read capability configuration 4 Cont. Table 40. 8 Bytes Number of synchronous mode read configuration fields that follow. 4 Bank and erase block region information(1) (2) TOP DEVICES BOTTOM DEVICES Description Offset Data Offset Data (P+19)h = 52h 02h (P+19)h = 52h 02h Number of Bank Regions within the device 1. The variable P is a pointer which is defined at CFI offset 15h. 2. Bank Regions. There are two Bank Regions, see Table 29 and Table 30 for the M58WR016QT/B and see Table 31 and Table 32 for the M58WR032QT/B. 88/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 41. Common Flash Interface Bank and erase block region 1 information(1) TOP DEVICES BOTTOM DEVICES Description Offset Data Offset Data (P+1A)h = 53h 01h 03h(2) (P+1A)h = 53h (P+1B)h = 54h (P+1C)h = 55h (P+1D)h = 56h (P+1E)h = 57h 07h(3) 00h 11h 00h 00h Number of identical banks within Bank Region 1 (P+1B)h = 54h (P+1C)h = 55h (P+1D)h = 56h (P+1E)h = 57h 00h 11h Number of program or erase operations allowed in Bank region 1: Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in same region is programming Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is erasing Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations Types of erase block regions in Bank region 1 n = number of erase block regions with contiguous same-size erase blocks. Symmetrically blocked banks have one blocking region.(4) (P+1F)h = 58h 01h (P+1F)h = 58h 02h (P+20)h = 59h 07h (P+20)h = 59h 07h (P+21)h = 5Ah 00h (P+21)h = 5Ah 00h (P+22)h = 5Bh 00h (P+22)h = 5Bh 20h (P+23)h = 5Ch 01h (P+23)h = 5Ch 00h (P+24)h = 5Dh 64h (P+24)h = 5Dh 64h (P+25)h = 5Eh 00h (P+25)h = 5Eh 00h (P+26)h = 5Fh (P+27)h = 60h 01h 03h (P+26)h = 5Fh (P+27)h = 60h Bank Region 1 Erase Block Type 1 Information Bits 0-15: n+1 = number of identical-sized erase blocks in each bank Bits 16-31: n×256 = number of bytes in erase block region Bank Region 1 (Erase Block Type 1) Minimum block erase cycles × 1000 01h Bank Region 1 (Erase Block Type 1): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 5Eh 01 5Eh 01 03h Bank Region 1 (Erase Block Type 1): Page mode and synchronous mode capabilities Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved 89/110 Common Flash Interface Table 41. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Bank and erase block region 1 information(1) (continued) TOP DEVICES BOTTOM DEVICES Description Offset Data Offset Data (P+28)h = 61h 06h Bank Region 1 Erase Block Type 2 Information (P+29)h = 62h 00h (P+2A)h = 63h 00h Bits 0-15: n+1 = number of identical-sized erase blocks (P+2B)h = 64h 01h Bits 16-31: n×256 = number of bytes in erase block region (P+2C)h = 65h 64h (P+2D)h = 66h 00h (P+2E)h = 67h (P+2F)h = 68h Bank Region 1 (Erase Block Type 2) Minimum block erase cycles × 1000 01h Bank Region 1 (Erase Block Type 2): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 03h Bank Region 1 (Erase Block Type 2): Page mode and synchronous mode capabilities Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved 1. The variable P is a pointer which is defined at CFI offset 15h. 2. Applies to the M58WR016QT/B only. 3. Applies to the M58WR032QT/B only. 4. Bank Regions. There are two Bank Regions, see Table 29 and Table 30 for the M58WR016QT/B and see Table 31 and Table 32 for the M58WR032QT/B. 90/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 42. Common Flash Interface Bank and erase block region 2 information(1) TOP DEVICES BOTTOM DEVICES Description Offset Data Offset (P+28)h = 61h 01h (P+30)h = 69h (P+29)h = 62h 00h (P+31)h = 6Ah Data 03h(2) (P+2A)h = 63h (P+2B)h = 64h (P+2C)h = 65h 11h 00h 00h (P+32)h = 6Bh (P+33)h = 6Ch (P+34)h = 6Dh 07h(3) Number of identical banks within bank region 2 00h 11h Number of program or erase operations allowed in bank region 2: Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is programming Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is erasing Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations Types of erase block regions in Bank region 2 n = number of erase block regions with contiguous same-size erase blocks. Symmetrically blocked banks have one blocking region.(4) (P+2D)h = 66h 02h (P+35)h = 6Eh 01h (P+2E)h = 67h 06h (P+36)h = 6Fh 07h (P+2F)h = 68h 00h (P+37)h = 70h 00h (P+30)h = 69h 00h (P+38)h = 71h 00h (P+31)h = 6Ah 01h (P+39)h = 72h 01h (P+32)h = 6Bh 64h (P+3A)h = 73h 64h (P+33)h = 6Ch 00h (P+3B)h = 74h 00h (P+34)h = 6Dh 01h (P+3C)h = 75h 01h Bank Region 2 Erase Block Type 1 Information Bits 0-15: n+1 = number of identical-sized erase blocks in each bank Bits 16-31: n×256 = number of bytes in erase block region Bank Region 2 (Erase Block Type 1) Minimum block erase cycles × 1000 Bank Region 2 (Erase Block Type 1): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 91/110 Common Flash Interface Table 42. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Bank and erase block region 2 information(1) (continued) TOP DEVICES BOTTOM DEVICES Description Offset Data (P+35)h = 6Eh 03h (P+36)h = 6Fh 07h (P+37)h = 70h 00h (P+38)h = 71h 20h (P+39)h = 72h 00h (P+3A)h = 73h 64h (P+3B)h = 74h 00h (P+3C)h = 75h (P+3D)h = 76h Offset (P+3D)h = 76h Data 03h Bank Region 2 (Erase Block Type 1): Page mode and synchronous mode capabilities (defined in Table 39) Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved Bank Region 2 Erase Block Type 2 Information Bits 0-15: n+1 = number of identical-sized erase blocks Bits 16-31: n×256 = number of bytes in erase block region Bank Region 2 (Erase Block Type 2) Minimum block erase cycles × 1000 01h Bank Region 2 (Erase Block Type 2): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 03h Bank Region 2 (Erase Block Type 2): Page mode and synchronous mode capabilities (defined in Table 39) Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved (P+3E)h = 77h (P+3E)h = 77h Feature Space definitions (P+3F)h = 78h (P+3F)h = 78h Reserved 1. The variable P is a pointer which is defined at CFI offset 15h. 2. Applies to the M58WR016QT/B only. 3. Applies to the M58WR032QT/B only. 4. Bank Regions. There are two Bank Regions, see Table 29 and Table 30 for the M58WR016QT/B and see Table 31 and Table 32 for the M58WR032QT/B. 92/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Appendix C Flowcharts and pseudo codes Flowcharts and pseudo codes Figure 20. Program flowchart and pseudo code Start program_command (addressToProgram, dataToProgram) {: " writeToFlash (addressToProgram, 0x40); /*writeToFlash (addressToProgram, 0x10);*/ /*see note (3)*/ " writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write 40h or 10h (3) Write Address & Data do { status_register=readFlash (addressToProgram); "see note (3)"; /* E or G must be toggled*/ Read Status Register (3) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06170b 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. 3. Any address within the bank can equally be used. 93/110 Flowcharts and pseudo codes M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 21. Double Word Program flowchart and pseudo code Start Write 35h double_word_program_command (addressToProgram1, dataToProgram1, addressToProgram2, dataToProgram2) { writeToFlash (addressToProgram1, 0x35); /*see note (4)*/ writeToFlash (addressToProgram1, dataToProgram1) ; /*see note (3) */ writeToFlash (addressToProgram2, dataToProgram2) ; /*see note (3) */ /*Memory enters read status state after the Program command*/ Write Address 1 & Data 1 (3, 4) Write Address 2 & Data 2 (3) do { status_register=readFlash (addressToProgram) ; "see note (4)" /* E or G must be toggled*/ Read Status Register (4) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06171b 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase operations. 3. Address 1 and Address 2 must be consecutive addresses differing only for bit A0. 4. Any address within the bank can equally be used. 94/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Flowcharts and pseudo codes Figure 22. Quadruple Word Program flowchart and pseudo code Start quadruple_word_program_command (addressToProgram1, dataToProgram1, addressToProgram2, dataToProgram2, addressToProgram3, dataToProgram3, addressToProgram4, dataToProgram4) { writeToFlash (addressToProgram1, 0x56); /*see note (4) */ Write 56h Write Address 1 & Data 1 (3, 4) writeToFlash (addressToProgram1, dataToProgram1) ; /*see note (3) */ Write Address 2 & Data 2 (3) writeToFlash (addressToProgram2, dataToProgram2) ; /*see note (3) */ writeToFlash (addressToProgram3, dataToProgram3) ; /*see note (3) */ Write Address 3 & Data 3 (3) writeToFlash (addressToProgram4, dataToProgram4) ; /*see note (3) */ Write Address 4 & Data 4 (3) /*Memory enters read status state after the Program command*/ do { status_register=readFlash (addressToProgram) ; /"see note (4) "/ /* E or G must be toggled*/ Read Status Register (4) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06977b 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase operations. 3. Address 1 to Address 4 must be consecutive addresses differing only for bits A0 and A1. 4. Any address within the bank can equally be used. 95/110 Flowcharts and pseudo codes M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 23. Program Suspend & Resume flowchart and pseudo code Start program_suspend_command ( ) { writeToFlash (any_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if program has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR2 = 1 NO Program Complete if (status_register.SR2==0) /*program completed */ { writeToFlash (bank_address, 0xFF) ; read_data ( ) ; /*The device returns to Read Array (as if program/erase suspend was not issued).*/ Write FFh YES Read Data } else Write FFh { writeToFlash (bank_address, 0xFF) ; Read data from another address read_data ( ); /*read data from another address*/ writeToFlash (any_address, 0xD0) ; /*write 0xD0 to resume program*/ Write D0h writeToFlash (bank_address, 0x70) ; /*read status register to check if program has completed */ Write 70h(1) } Program Continues with Bank in Read Status Register Mode } AI10117b 1. The Read Status Register command (Write 70h) can be issued just before or just after the Program Resume command. 96/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Flowcharts and pseudo codes Figure 24. Block Erase flowchart and pseudo code Start erase_command ( blockToErase ) { writeToFlash (blockToErase, 0x20) ; /*see note (2) */ Write 20h (2) writeToFlash (blockToErase, 0xD0) ; /* only A12-Amax(3) are significant */ /* Memory enters read status state after the Erase Command */ Write Block Address & D0h do { status_register=readFlash (blockToErase) ; /* see note (2) */ /* E or G must be toggled*/ Read Status Register (2) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1) YES Command Sequence Error (1) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; YES SR4, SR5 = 1 if ( (status_register.SR4==1) && (status_register.SR5==1) ) /* command sequence error */ error_handler ( ) ; NO SR5 = 0 NO Erase Error (1) if ( (status_register.SR5==1) ) /* erase error */ error_handler ( ) ; YES SR1 = 0 NO Erase to Protected Block Error (1) if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI10185 1. If an error is found, the Status Register must be cleared before further Program/Erase operations. 2. Any address within the bank can be used also. 3. Amax is equal to A19 in the M58WR016QT/B and to A20 in the M58WR032QT/B. 97/110 Flowcharts and pseudo codes M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 25. Erase Suspend & Resume flowchart and pseudo code Start erase_suspend_command ( ) { writeToFlash (bank_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if erase has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR6 = 1 NO Erase Complete if (status_register.SR6==0) /*erase completed */ { writeToFlash (bank_address, 0xFF) ; Write FFh read_data ( ) ; /*The device returns to Read Array (as if program/erase suspend was not issued).*/ Read Data YES Write FFh } else { writeToFlash (bank_address, 0xFF) ; read_program_data ( ); Read data from another block or Program/Protection Register Program or Block Lock/Unlock/Lock-Down /*read or program data from another block*/ writeToFlash (bank_address, 0xD0) ; /*write 0xD0 to resume erase*/ Write D0h writeToFlash (bank_address, 0x70) ; /*read status register to check if erase has completed */ Write 70h(1) } } Erase Continues with Bank in Read Status Register Mode AI10116b 1. The Read Status Register command (Write 70h) can be issued just before or just after the Erase Resume command. 98/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Flowcharts and pseudo codes Figure 26. Locking operations flowchart and pseudo code Start locking_operation_command (address, lock_operation) { writeToFlash (address, 0x60) ; /*configuration setup*/ /* see note (1) */ Write 60h (1) if (lock_operation==LOCK) /*to protect the block*/ writeToFlash (address, 0x01) ; else if (lock_operation==UNLOCK) /*to unprotect the block*/ writeToFlash (address, 0xD0) ; else if (lock_operation==LOCK-DOWN) /*to lock the block*/ writeToFlash (address, 0x2F) ; Write 01h, D0h or 2Fh writeToFlash (address, 0x90) ; /*see note (1) */ Write 90h (1) Read Block Lock States Locking change confirmed? if (readFlash (address) ! = locking_state_expected) error_handler () ; /*Check the locking state (see Read Block Signature table )*/ NO YES writeToFlash (address, 0xFF) ; /*Reset to Read Array mode*/ /*see note (1) */ Write FFh (1) } End AI06176b 1. Any address within the bank can equally be used. 99/110 Flowcharts and pseudo codes M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Figure 27. Protection Register Program flowchart and pseudo code Start protection_register_program_command (addressToProgram, dataToProgram) {: writeToFlash (addressToProgram, 0xC0) ; /*see note (3) */ Write C0h (3) writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write Address & Data do { status_register=readFlash (addressToProgram) ; /* see note (3) */ /* E or G must be toggled*/ Read Status Register (3) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06177b 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. 3. Any address within the bank can equally be used. 100/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Flowcharts and pseudo codes Figure 28. Enhanced Factory Program flowchart SETUP PHASE VERIFY PHASE Start Write PD1 Address WA1(1) Write 30h Address WA1 Write D0h Address WA1 Read Status Register Read Status Register SR0 = 0? NO Check SR4, SR3 and SR1 for program, VPP and Lock Errors SR7 = 0? Exit PROGRAM PHASE YES Write PD2 Address WA2(1) YES SR0 = 0? NO NO YES Read Status Register Write PD1 Address WA1 SR0 = 0? Read Status Register NO YES NO SR0 = 0? Write PDn Address WAn(1) YES Write PD2 Address WA2(1) Read Status Register Read Status Register SR0 = 0? NO YES SR0 = 0? NO Write FFFFh Address =/ Block WA1 YES EXIT PHASE Write PDn Address WAn(1) Read Status Register Read Status Register SR7 = 1? NO YES SR0 = 0? NO Check Status Register for Errors YES Write FFFFh Address =/ Block WA1 End AI06160 1. Address can remain Starting Address WA1 or be incremented. 101/110 Flowcharts and pseudo codes C.1 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Enhanced Factory Program pseudo code efp_command(addressFlow,dataFlow,n) /* n is the number of data to be programmed */ { /* setup phase */ writeToFlash(addressFlow[0],0x30); writeToFlash(addressFlow[0],0xD0); status_register=readFlash(any_address); if (status_register.SR7==1){ /*EFP aborted for an error*/ if (status_register.SR4==1) /*program error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR1==1) /*program to protect block error*/ error_handler(); } else{ /*Program Phase*/ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ } while (status_register.SR0==1) /*Ready for first data*/ for (i=0; i++; i< n){ writeToFlash(addressFlow[i],dataFlow[i]); /* status register polling*/ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ } while (status_register.SR0==1); /* Ready for a new data */ } writeToFlash(another_block_address,FFFFh); /* Verify Phase */ for (i=0; i++; i< n){ writeToFlash(addressFlow[i],dataFlow[i]); /* status register polling*/ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ } while (status_register.SR0==1); /* Ready for a new data */ } writeToFlash(another_block_address,FFFFh); /* exit program phase */ /* Exit Phase */ /* status register polling */ do{ status_register=readFlash(any_address); /* E or G must be toggled */ } while (status_register.SR7==0); if (status_register.SR4==1) /*program failure error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR1==1) /*program to protect block error*/ error_handler(); } } 102/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Flowcharts and pseudo codes Figure 29. Quadruple Enhanced Factory Program flowchart SETUP PHASE LOAD PHASE Start Write 75h Address WA1 FIRST LOAD PHASE Write PD1 Address WA1 Read Status Register Write PD1 Address WA1(1) Write PD2 Address WA2(2) Write PD3 Address WA3(2) NO SR7 = 0? YES Write PD4 Address WA4(2) EXIT PHASE Check SR4, SR3 and SR1 for program, VPP and Lock Errors PROGRAM AND VERIFY PHASE Read Status Register Write FFFFh Address = / Block WA1 Exit NO SR0 = 0? YES Check SR4 for Programming Errors End Last Page? NO YES AI06178b 1. Address can remain Starting Address WA1 (in which case the next Page is programmed) or can be any address in the same block. 2. The address is only checked for the first Word of each Page as the order to program the Words is fixed, so subsequent Words in each Page can be written to any address. 103/110 Flowcharts and pseudo codes C.2 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Quadruple Enhanced Factory Program Pseudo Code quad_efp_command(addressFlow,dataFlow,n) /* n is the number of pages to be programmed.*/ { /* Setup phase */ writeToFlash(addressFlow[0],0x75); for (i=0; i++; i< n){ /*Data Load Phase*/ /*First Data*/ writeToFlash(addressFlow[i],dataFlow[i,0]); /*at the first data of the first page, Quad-EFP may be aborted*/ if (First_Page) { status_register=readFlash(any_address); if (status_register.SR7==1){ /*EFP aborted for an error*/ if (status_register.SR4==1) /*program error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR1==1) /*program to protect block error*/ error_handler(); } } /*2nd data*/ writeToFlash(addressFlow[i],dataFlow[i,1]); /*3rd data*/ writeToFlash(addressFlow[i],dataFlow[i,2]); /*4th data*/ writeToFlash(addressFlow[i],dataFlow[i,3]); /* Program&Verify Phase */ do{ status_register=readFlash(any_address); /* E or G must be toggled*/ }while (status_register.SR0==1) } /* Exit Phase */ writeToFlash(another_block_address,FFFFh); /* status register polling */ do{ status_register=readFlash(any_address); /* E or G must be toggled */ } while (status_register.SR7==0); if (status_register.SR1==1) /*program to protected block error*/ error_handler(); if (status_register.SR3==1) /*VPP invalid error*/ error_handler(); if (status_register.SR4==1) /*program failure error*/ error_handler(); } } 104/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Appendix D Table 43. Command interface state tables Command interface state tables Command interface states - modify table, next state(1) Command Input Current CI State Read Array(2) (FFh) Ready Ready Block DWP, Erase, EFP QWP Bank Erase Setup (3)(4) Setup (3)(4) (30h) (10/40h) (35h, 56h) Setup (20h, 80h) QuadEFP Setup (75h) Program Setup QuadEFP Setup WP setup(3)(4) Lock/CR Setup Program Setup Erase Setup EFP Setup Erase Confirm P/E Resume, Block Unlock confirm, EFP Confirm (D0h) Read Program/ Read Clear Electronic Erase Status Status signature, Suspend Register Register Read CFI (B0h) (70h) (5)(50h) Query (90h, 98h) Ready Ready (Lock Error) Ready Ready (Lock Error) Setup OTP OTP Busy Busy Setup Program Erase Program Busy Busy Program Suspended Program Busy Program Suspended Setup Ready (error) Erase Busy Ready (error) Busy Busy Suspend Lock/CR Setup in Erase Suspend Setup Quad EFP 1. Erase Suspended Erase Busy Erase Suspended Program in Erase Suspend Erase Suspended Setup EFP Program Busy Suspend Suspend Program in Erase Suspend Program Suspended Program Busy Erase Busy Erase Busy Erase Suspended Program Busy in Erase Suspend Program Suspend in Erase Suspend Program Busy in Erase Suspend Program Busy in Erase Suspend Program Suspend in Erase Suspend Program Busy in Erase Suspend Program Suspend in Erase Suspend Erase Suspend (Lock Error) Erase Suspend Erase Suspend (Lock Error) EFP Busy Ready (error) Ready (error) (6) Busy EFP Busy Verify EFP Verify(6) Setup Quad EFP Busy(6) Busy Quad EFP Busy(6) CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, DWP = Double Word Program, QWP = Quadruple Word Program, P/E. C. = Program/Erase Controller. 2. At Power-Up, all banks are in Read Array mode. A Read Array command issued to a busy bank, results in undetermined data output. 3. The two cycle command should be issued to the same bank address. 4. If the P/E.C. is active, both cycles are ignored. 5. The Clear Status Register command clears the Status Register error bits except when the P/E.C. is busy or suspended. 6. EFP and Quad EFP are allowed only when Status Register bit SR0 is set to ‘0’.EFP and Quad EFP are busy if Block Address is first EFP Address. Any other commands are treated as data. 105/110 Command interface state tables Table 44. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Command interface states - modify table, next output state Command Input(1) (2) Current CI State Erase Confirm WP Clear Block Erase, Quad- P/E Resume, Program/ Read DWP, EFP Read (4) status Status Erase Bank Erase EFP Block Unlock QWP (3) Setup Setup Array ( (5) Setup confirm, EFP Suspend Register Register(6) Setup(4)(5) Setup(4)(5) FFh) (30h) Confirm (70h) (B0h) (75h) (35h, 56h) (20h, 80h) (50h) (10/40h) (D0h) Read Electronic signature, Read CFI Query (90h, 98h) Program Setup Erase Setup OTP Setup Program in Erase Suspend EFP Setup EFP Busy Status Register EFP Verify Quad EFP Setup Quad EFP Busy Lock/CR Setup Lock/CR Setup in Erase Suspend Status Register OTP Busy Ready Program Busy Erase Busy Array Status Register Program/Erase Output Unchanged Status Output Register Unchanged Electronic Signature/CFI Program Busy in Erase Suspend Program Suspend in Erase Suspend 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, DWP = Double Word Program, QWP = Quadruple Word Program, P/E. C. = Program/Erase Controller. 2. The output state shows the type of data that appears at the outputs if the bank address is the same as the command address. A bank can be placed in Read Array, Read Status Register, Read Electronic Signature or Read CFI Query mode, depending on the command issued. Each bank remains in its last output state until a new command is issued. The next state does not depend on the bank’s output state. 3. At Power-Up, all banks are in Read Array mode. A Read Array command issued to a busy bank, results in undetermined data output. 4. The two cycle command should be issued to the same bank address. 5. If the P/E.C. is active, both cycles are ignored. 6. The Clear Status Register command clears the Status Register error bits except when the P/E.C. is busy or suspended. 106/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Table 45. Command interface state tables Command interface states - lock table, next state Command Input(1) Current CI State Ready Lock/CR Setup Lock/CR Setup(2) (60h) OTP Setup(2) (C0h) Lock/CR Setup OTP Setup Block Lock Confirm (01h) Block LockDown Confirm (2Fh) Set CR Confirm (03h) EFP Exit, Quad EFP Exit(3) Illegal Command (4) P/E. C. Operation Completed Ready Ready (Lock error) Ready N/A Ready (Lock error) N/A Setup N/A OTP OTP Busy Busy Program Ready Setup Program Busy N/A Busy Program Busy Ready Suspend Program Suspended N/A Setup Ready (error) N/A Busy Erase Busy Ready Erase Suspend Program in Erase Suspend Lock/CR Setup in Erase Suspend Erase Suspended N/A Setup Program Busy in Erase Suspend N/A Busy Program Busy in Erase Suspend Erase Suspended Suspend Program Suspend in Erase Suspend N/A Lock/CR Setup in Erase Suspend Erase Suspend (Lock error) Erase Suspend Setup EFP Erase Suspend (Lock error) N/A Ready (error) N/A Busy EFP Busy(5) EFP Verify EFP Busy(5) N/A Verify EFP Verify(5) Ready EFP Verify(5) Ready Quad EFP Busy(5) Setup N/A QuadEFP Busy Quad EFP Busy(5) Ready Quad EFP Busy(5) Ready 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, P/E. C. = Program/Erase Controller. 2. If the P/E.C. is active, both cycles are ignored. 3. EFP and Quad EFP exit when Block Address is different from first Block Address and data is FFFFh. 4. Illegal commands are those not defined in the command set. 5. EFP and Quad EFP are allowed only when Status Register bit SR0 is set to ‘0’. EFP and Quad EFP are busy if Block Address is first EFP Address. Any other commands are treated as data. 107/110 Command interface state tables Table 46. M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Command interface states - lock table, next output state Command Input(1) Current CI State Lock/CR Setup(2) (60h) OTP Setup(2) (C0h) Block Lock Confirm (01h) Block LockDown Confirm (2Fh) Set CR Confirm (03h) EFP Exit, Quad EFP Exit(3) Illegal Command (4) P/E. C. Operation Completed Program Setup Erase Setup OTP Setup Program in Erase Suspend Output Unchanged Status Register EFP Setup EFP Busy EFP Verify Quad EFP Setup Quad EFP Busy Lock/CR Setup Lock/CR Setup in Erase Suspend OTP Busy Status Register Array Status Register Output Unchanged Status Register Output Unchanged Array Output Unchanged Output Unchanged Status Register Output Unchanged Array Output Unchanged Output Unchanged Ready Program Busy EraseBusy Program/Erase Program Busy in Erase Suspend Program Suspend in Erase Suspend 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Factory Program, P/E. C. = Program/Erase Controller. 2. If the P/E.C. is active, both cycles are ignored. 3. EFP and Quad EFP exit when Block Address is different from first Block Address and data is FFFFh. 4. Illegal commands are those not defined in the command set. 108/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB 17 Revision history Revision history Table 47. Document revision history Date Revision 15-Sep-2004 0.1 Changes First Issue 14-Apr-2006 1 Document status promoted from Target Specificaton to full Datasheet. Small text changes. Address modified for Clear Status Register command in Table 6: Standard commands. Test condition modified for IDD3 and IDD7 in Table 19: DC characteristics - currents. VPP1 min modified and VLKO value moved from Min to Max in Table 20: DC characteristics - voltages. tWHQV removed from Figure 16, Table 23, Figure 17 and Table 24. Note 3 modified. Data modified at address offset 31h in Table 36. Figure 23: Program Suspend & Resume flowchart and pseudo code and Figure 25: Erase Suspend & Resume flowchart and pseudo code modified. 12-Nov-2007 2 Applied Numonyx branding. 109/110 M58WR016QT, M58WR016QB, M58WR032QT, M58WR032QB Please Read Carefully: INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYX™ PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN NUMONYX'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY WHATSOEVER, AND NUMONYX DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications. Numonyx may make changes to specifications and product descriptions at any time, without notice. Numonyx, B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Numonyx reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Numonyx literature may be obtained by visiting Numonyx's website at http://www.numonyx.com. Numonyx StrataFlash is a trademark or registered trademark of Numonyx or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 11/5/7, Numonyx, B.V., All Rights Reserved. 110/110