Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] The ACTF00038/947.50/DCC6Cis a low-loss, wide band SAW filter in a surface-mount ceramic DCC6C case for GSM Tx etc. 1. Package Dimension (DCC6C) 2. Pin Configuration 2 Input 5 Output 1,3,4,6 Ground Sign Data (unit: mm) Sign Data (unit: mm) A 1.9 E 1.2 B 0.64 F 3.8 C 1.0 G 3.8 D 1.27 3. Matching Circuit In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1.1 C1 Date : March 2010 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] 4. Typical frequency response 5. Performance 5-1.Maximum Ratings Rating Input Power Level PIN DC Voltage VDC Value Unit 10 dBm 12 V Storage Temperature Range Tstg -40 to +85 °C Operating Temperature Range TA -10 to +65 °C In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1.1 C1 Date : March 2010 Tel : +44 118 979 1238 Fax : +44 118 979 1283 Email: [email protected] 5-2.Electronic Characteristics Parameter Centre Frequency fC Minimum Typical Maximum Unit -- 947.500 -- MHz 3dB Bandwidth BW3 -- ±21 -- MHz Usable Bandwidth BWUSE -- ±15 -- MHz -- 2.7 3.6 dB -- 1.0 1.8 dB 45 18 20 48 54 25 28 58 ----- dB Insertion Loss IL 932.50 MHz …. 962.50 MHz Amplitude Variation (p-p) 932.50 MHz …. 962.50 MHz Δα Absolute Attenuation α DC …. 885.00 MHz 885.00 MHz …. 915.00 MHz 990.00 MHz …. 1050.0 MHz 1050.0 MHz …. 2000.0 MHz Input / Output Impedance Ω 50 iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling! 1. 2. 3. 4. 5. 6. The frequency f C is defined as the midpoint between the 3dB frequencies. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is connected to a 50Ω test system with VSWR≤1.2:1. The test fixture L and C are adjusted for minimum insertion loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on the impedance matching component values and quality. Unless noted otherwise, specifications apply over the entire specified operating temperature range. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence without notice. All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications, processes and circuits implemented within components or assemblies. In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice. ISO9001: 2000 Registered For quotations or further information please contact us at: 3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK http://www.actcrystals.com Issue : 1.1 C1 Date : March 2010