Artesyn LCC250-24U-7PE 250 watts convection/conduction mounting Datasheet

POWER
LCC250
250 Watts Convection/Conduction Mounting
Data Sheet
Total Power: 250 W
# of Outputs: Single
Outputs:
12, 24, 48 V
SPECIAL FEATURES
ƒƒ 250 W full power at elevated
temperatures
ƒƒ Wide operating temperature range
suited for outdoor application
ƒƒ IP64 rated
ƒƒ Conduction-cooled or convection
ƒƒ Differential remote sense
ƒƒ Output adjust
ƒƒ Output On/Off (Positive or Negative
logic user selectable)
COMPLIANCE
ƒƒ EMI Class B
ƒƒ EN61000 Immunity
ƒƒ MIL-STD-461E: CE101; CE102;
CS101; CS114
SAFETY
ƒƒ UL + CSA:
60950-1 2nd Ed.
ANSI ES60601-1
3rd Ed
ƒƒ TUV:
60950-1 2nd Ed.
60601-1 3rd Ed.
61347-1; 2-13
ƒƒ CB Scheme: IEC 60950-1 2nd Ed
IEC 61347-1; 2-13
IEC 60601-1
ƒƒ China
CCC5
ƒƒ CE Mark
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac (Operating)
115/230 Vac (Nominal)
Frequency
47 - 63 Hz
Input fusing
Internal fuse on both L and N lines
Inrush current
50 A
Power factor
> 0.92 Full load
Harmonics
Meets EN61000-3-2; MIL-STD-461E(6); CE101; CE102; CS101; CS104
Input current
3.4 A @ 90 Vac full load
Hold up time
16 ms minimum at 115 Vac; 100% load
Efficiency
230 Vac; 100% load
12 V - 89% typical
24 V - 91% typical
48 V - 91.5% typical
Leakage current
< 275 μA at 230 Vac
LCC250 Data Sheet
Electrical Specifications
Output
Output rating
12 V @ 20.8 A
24 V @ 10.4 A
48 V @ 5.2 A
Set point
±0.2%
Factory set point
Total regulation range
±2%
Line/Load/Temperature
Rated load
250 W maximum
Minimum load
0 A Load
Capacitive load
0 - 330 μF/Amp
Output voltage overshoot
No loss of regulation
No overshoot/undershoot outside the regulation band during
on or off cycle
Constant output voltage
adjustment range
12 V: +10 / -10%
24 V: +14.6 / -15%
48 V: +15% / -15%
Adjust via VR2
Constant output current
adjustment range
+0 / -50%
Adjust via VR1
CC mode supported from Vo nominal down to 80% Vo
Output ripple and noise
1﹪
0 to 330 μF/Amp
Transient response
±5% Vo max transient;
recovery < 500 μs max
50% Load Step @ 1 A/μs
Step Load verified at: 50% to 100% Load; 90 - 264 Vac
input; Capacitive load from 0 to 330 μF/Amp
Remote sense
Capable of Stable Offset of ±0.5 Vdc at output
cable termination
+SENSE (Red Wire); -SENSE (Black Wire)
Output On/Off
Remote On/Off referenced to secondary side.
Positive or Negative logic user selectable via CN2.
Factory default is Positive logic
On/Off (Orange Wire); On/Off Return (White Wire)
Overcurrent protection (OCP)
≤ 150% Io
Auto-recovery
Overvoltage protection (OVP)
110% to 135% Vo
Latching mode; Requires input AC recycle
Overtemperature Protection (OTP)
Output isolation
Auto-recovery; hiccup mode
4000 Vac Input to Output
1500 Vac Input to Ground
500 Vac Output to Ground
Environmental Specifications
Operating temperature
Suffix 4P (Conduction): -40 °C to +85 °C Baseplate Temperature
Suffix 7P (Convection): -40 °C to +85 °C Ambient Temperature
Storage temperature
-40 °C to +85 °C
Humidity
10% to 100% (Condensing & Non-Condensing)
Altitude
Operating: 13,000 feet
Non-Operating: 50,000 feet
Shock
IEC68-2-27
Vibration
IEC68-2-6 / IEC721-3-2
Ingress Protection
IP64 Rated
MTBF (Calculated)
> 780,000 hours at 100% load; Low line; Telcordia SR-332
LCC250 Data Sheet
Ordering Information
Output Current
Output
Adjustment Range
Min
Max
Output Ripple
P/P1
Line/
Load Regulation
LCC250-12U-4P
12 V
±10%
0A
20.8 A
1% 2
±2%
LCC250-12U-4PE
12 V
±10%
0A
20.8 A
1% 2
±2%
LCC250-12U-7P
12 V
±10%
0A
20.8 A
1%
2
±2%
LCC250-12U-7PE
12 V
±10%
0A
20.8 A
1% 2
±2%
LCC250-24U-4P
24 V
+14.6 / -15%
0A
10.4 A
1%
3
±2%
LCC250-24U-4PE
24 V
+14.6 / -15%
0A
10.4 A
1% 3
±2%
LCC250-24U-7P
24 V
+14.6 / -15%
0A
10.4 A
1%
3
±2%
LCC250-24U-7PE
24 V
+14.6 / -15%
0A
10.4 A
1% 3
±2%
LCC250-48U-4P
48 V
±15%
0A
5.2 A
1%
4
±2%
LCC250-48U-4PE
48 V
±15%
0A
5.2 A
1%
4
±2%
LCC250-48U-7P
48 V
±15%
0A
5.2 A
1% 4
±2%
LCC250-48U-7PE
48 V
±15%
0A
5.2 A
1%
±2%
Model Number
4
1. Output ripple measured at the end of the output cable terminated with 10 μF tantalum cap in parallel with 0.1 μF ceramic capacitor.
2. 12 V: 1% limit is achieved with 2X 820 uF/16 V external cap (e.g. PLG1C821MDO1 from Nichicon or equivalent). Otherwise, maximum
limits are 1.5% at Ta ≥ 0 °C and 2.0% max at Ta < 0 °C.
3. 24 V: 1% limit is achieved with 2X 820 uF/35 V external cap (e.g. UPM1V821MHD1TO from Nichicon or equivalent). Otherwise,
maximum limits are 1.5% at Ta ≥ -10 °C. 2.0% max ripple at Ta < -10 °C is met with below external capacitance:
Ambient Temperature (°C)
Recommended External Capacitors (μF)
-20
-25
-30
-35
-40
1000
2200
3300
12000
22000
4. 48 V: 1% limit is achieved with 3X 470 uF/63 V external cap. Otherwise, maximum limits are 1.5% max at Ta ≥ 0 °C and 2% max at
Ta < 0 °C.
5. Safety Approvals: China CCC approval applies to part numbers with “-xxE” suffixes only.
6. 12 V unit requires external filtering for MIL-STD-461E compliance. Consult Artesyn Technical Support.
7. Warranty: 2 years
LCC250 Data Sheet
LCC250-12U-4P (Conduction)
115/180/230 Vac
15
230 Vac
180 Vac
115 Vac
90 Vac
10
5
0
25
35
45
55
65
75
LCC250-12U-7P (Convection)
VIN = 115 Vac
25
20
Output Current (A)
Output Current (A)
25
85
20
15
NAT CONV
100 LFM
10
200 LFM
5
300 LFM
400 LFM
0
95
25
35
Baseplate Temperature (˚C)
95%
90%
20
15
Efficiency (%)
Output Current (A)
85
12V Efficiency vs. Input Line
LCC250-12U-7P (Conduction)
VIN = 230 Vac
NAT CONV
10
100 LFM
200 LFM
5
300 LFM
25
35
85%
80%
75%
Vin = 115 Vac
70%
400 LFM
0
45
55
65
75
Vin = 230 Vac
65%
85
0%
Ambient Temperature (˚C)
20%
LCC250-24U-4P (Conduction)
12
Output Current (A)
10
6
90 Vac
4
115 Vac
230 Vac
2
264 Vac
25
35
45
55
65
75
85
Baseplate Temperature (˚C)
Fig 5. 24 V “4P” Suffix (Conduction) Output Current Derating
95
100%
10
8
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
6
4
2
0
0
80%
LCC250-24U-7P (Convection)
VIN = 115 Vac
12
8
40%
60%
Output Load
Fig 4. 12 V Efficiency Curve
Fig 3. 12 V “7P” Suffix (Convection) Output Current Derating at 230 Vac
Output current (A)
75
Fig 2. 12 V “7P” Suffix (Convection) Output Current Derating at 115 Vac
Fig 1. 12 V “4P” Suffix (Conduction) Output Current Derating
25
45
55
65
Ambient Temperature (˚C)
25
35
45
55
65
75
85
Ambient Temperature (˚C)
Fig 6. 24 V “7P” Suffix (Convection) Output Current Derating at 115 Vac
LCC250 Data Sheet
12
95
90
10
8
Efficiency (%)
Output Current (A)
24 V Efficiency vs. Input Line
LCC250-24U-7P (Convection)
VIN = 230 Vac
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
6
4
2
85
80
75
115 Vac
70
230 Vac
65
0
25
35
45
55
65
75
0
85
20
40
Ambient Temperature (˚C)
6
5
5
Output Current (A)
Output Current (A)
6
4
90 Vac
115 Vac
230 Vac
264 Vac
1
0
25
35
45
55
65
LCC250-48U-7P (Convection)
VIN = 115 Vac
75
85
4
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
3
2
1
0
95
25
35
Baseplate Temperature (˚C)
55
65
75
85
Fig 10. 48 V “7P” Suffix (Convection) Output
LCC250-48U-7P (Convection)
VIN = 230 Vac
48 V Efficiency vs. Input Line
95
90
5
Efficiency (%)
Output Current (A)
45
Ambient Temperature (˚C)
Fig 9. 48 V “4P” Suffix (Conduction) Output Current Derating
6
100
Fig 8. 24 V Efficiency Curve
LCC250-48U-4P (Conduction)
2
80
Output Load (%)
Fig 7. 24 V “7P” Suffix (Convection) Output Current Derating at 230 Vac
3
60
4
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
3
2
1
85
80
75
Vin=115 Vac
70
0
Vin=230 Vac
65
25
35
45
55
65
Ambient Temperature (˚C)
75
85
Fig 11. 48 V “7P” Suffix (Convection) Output Current Derating at 230 Vac
0
20
40
60
Output Load (%)
Fig 12. 48 V Efficiency Curve
80
100
LCC250 Data Sheet
Mechanical Drawings
12 V
MODEL LABEL
L1
AC INPUT
POTTING TRIM LABEL
C
A
L2
DC OUTPUT
6-Ø 3.6 ±0.10
C
C
B
B
A
(4 - 63.5)
(2 - 93.8)
101.4 ±0.6
L3
CONTROL
A
B
B
C
C
(2 - 59.7)
A
M
BUSHING
C
(2 - 119.4)
(2 - 119.4)
(2 - 139.7)
ADJUST DIMMING
(VR1)
ADJUST REMOTE ON/OFF
(CN2)
SEE DETAIL C
177.6 ±0.6
VIEW M
ADJUST OUTPUT VOLTAGE
(VR2)
ON
(NEGATIVE POLARITY)
27.9 ±0.6
LCC250-12U-4P
0.30
OFF
(POSITIVE POLARITY)
SERIAL NO. BARCODE LABEL
DETAIL C
37.6 ±0.6
LCC250-12U-7P
24 V / 48 V
MODEL LABEL
POTTING TRIM LABEL
L1
AC INPUT
L2
DC OUTPUT
6-Ø 3.6 ±0.10
C
A
C
C
B
B
A
(4 - 63.5)
(2 - 93.8)
101.4 ±0.6
A
B
B
C
C
(2 - 59.7)
A
L3
CONTROL
BUSHING
C
(2 - 119.4)
(2 - 119.4)
(2 - 139.7)
ADJUST DIMMING
(VR1)
ADJUST REMOTE ON/OFF
(CN2)
SEE DETAIL C
177.6 ±0.6
VIEW M
27.9 ±0.6
LCC250-xxU-4P
SERIAL NO. BARCODE LABEL
(FOR 4PE/7PE ONLY)
ADJUST OUTPUT VOLTAGE
(VR2)
ON
(NEGATIVE POLARITY)
0.30
OFF
(POSITIVE POLARITY)
37.6 ±0.6
LCC250-xxU-7P
DETAIL C
LCC250 Data Sheet
Cable
AC Input Cable
DC Output Cable
Control Cable
Length
Designation
Wire Color
Wire Gauge
L1 = 300 ±10 mm
L = Live
Brown
AWG#18
N = Neutral
Blue
AWG#18
PE = Primary Earth
Green/Yellow
AWG#18
+Output
Blue
AWG#14
-Output
Gray
AWG#14
Dimming
Brown
AWG#26
Dimming Return
Yellow
AWG#26
ON/OFF
Orange
AWG#26
ON/OFF Return
White
AWG#26
Sense
Red
AWG#26
Sense Return
Black
AWG#26
L2 = 300 ±10 mm
L3 = 300 ±10 mm
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2015 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
LCC250 DS 29Oct2015
Similar pages