TI LM92 Accurate, 12-bit sign temperature sensor and thermal window comparator with two-wire interface Datasheet

LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
±0.33°C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator
With Two-Wire Interface
Check for Samples: LM92
FEATURES
DESCRIPTION
•
The LM92 is a digital temperature sensor and thermal
window comparator with an I2C™ Serial Bus interface
and an accuracy of ±0.33°C. The window-comparator
architecture of the LM92 eases the design of
temperature control systems. The open-drain
Interrupt (INT) output becomes active whenever
temperature goes outside a programmable window,
while a separate Critical Temperature Alarm
(T_CRIT_A) output becomes active when the
temperature exceeds a programmable critical limit.
The INT output can operate in either a comparator or
event mode, while the T_CRIT_A output operates in
comparator mode only.
1
23
•
•
•
•
•
•
Window Comparison Simplifies Design of
ACPI-Compatible Temperature Monitoring and
Control
Serial Bus Interface
Separate Open-Drain Outputs for Interrupt and
Critical Temperature Shutdown
Shutdown Mode to Minimize Power
Consumption
Up to Four LM92s can be Connected to a
Single Bus
12-Bit + Sign Output
Operation up to 150°C
APPLICATIONS
•
•
•
•
•
•
•
HVAC
Medical Electronics
Electronic Test Equipment
System Thermal Management
Personal Computers
Office Electronics
Automotive
KEY SPECIFICATIONS
•
•
•
•
•
The host can program both the upper and lower limits
of the window as well as the critical temperature limit.
Programmable Hysteresis as well as a fault queue
are available to minimize false tripping. Two pins (A0,
A1) are available for address selection. The sensor
powers up with default thresholds of 2°C THYST, 10°C
TLOW, 64°C THIGH, and 80°C T_CRIT.
The LM92's 2.7V to 5.5V supply voltage range, Serial
Bus interface, 12-bit + sign output, and full-scale
range of over 128°C make it ideal for a wide range of
applications. These include thermal management and
protection applications in personal computers,
electronic test equipment, office electronics,
automotive, medical and HVAC applications.
Supply Voltage 2.7V to 5.5V
Supply Current operating 350 μA (typ) 625 μA
(max) shutdown 5 μA (typ)
Temperature Accuracy
– 30°C, ±0.33°C (max)
– 10°C to 50°C, ±0.50°C (max)
– −10°C to 85°C, ±1.0°C (max)
– 125°C, ±1.25°C (max)
– −25°C to 150°C, ±1.5°C (max)
Linearity ±0.5°C (max)
Resolution 0.0625°C
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
I C is a trademark of dcl_owner.
All other trademarks are the property of their respective owners.
2
2
3
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2000–2013, Texas Instruments Incorporated
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
Simplified Block Diagram
Connection Diagram
SOIC
See Package Number D (R-PDSO-G8)
Pin Description
Label
Pin No.
Function
Typical Connection
SDA
1
Serial Bi-Directional Data Line. Open Drain Output
From Controller
SCL
2
Serial Bus Clock Input
From Controller
T_CRIT_A
3
Critical Temperature Alarm Open Drain Output
Pull Up Resistor, Controller Interrupt Line or System
Hardware Shutdown
GND
4
Power Supply Ground
Ground
INT
5
Interrupt Open Drain Output
Pull Up Resistor, Controller Interrupt Line
8
Positive Supply Voltage Input
DC Voltage from 2.7V to 5.5V
User-Set Address Inputs
Ground (Low, “0”) or +VS (High, “1”)
+V S
A0–A1
2
7,6
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
Typical Application
Figure 1.
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)
−0.3 V to 6.5V
Supply Voltage
−0.3 V to (+VS + 0.3V)
Voltage at any Pin
Input Current at any Pin
Package Input Current
5 mA
(2)
20 mA
T_CRIT_A and INT Output Sink Current
10 mA
T_CRIT_A and INT Output Voltage
6.5V
−65°C to +125°C
Storage Temperature
ESD Susceptibility
(3)
Human Body Model
2500V
Machine Model
250V
Soldering process must comply with Reflow Temperature Profile specifications. Refer to http://www.ti.com/lit/SNOA549. (4)
(1)
(2)
(3)
(4)
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not
apply when operating the device beyond its rated operating conditions.
When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > +VS) the current at that pin should be limited to 5
mA. The 20 mA maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input
current of 5 mA to four.
Human body model, 100 pF discharged through a 1.5 kΩ resistor. Machine model, 200 pF discharged directly into each pin.
Reflow temperature profiles are different for lead-free and non-lead-free packages.
Operating Ratings
(1) (2)
Specified Temperature Range (3), TMIN to TMAX
−55°C to +150°C
Supply Voltage Range (+VS)
(1)
(2)
(3)
+2.7V to +5.5V
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not
apply when operating the device beyond its rated operating conditions.
LM92 θJA (thermal resistance, junction-to-ambient) when attached to a printed circuit board with 2 oz. foil is 200 °C/W.
While the LM92 has a full-scale-range in excess of 128°C, prolonged operation at temperatures above 125 °C is not recommended.
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
3
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
Electrical Characteristics Temperature-to-Digital Converter Characteristics
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ
= TMIN to TMAX; all other limits TA= TJ= +25°C, unless otherwise noted.
Parameter
Conditions
Accuracy (This is a summary. For more
detailed information please see (3))
Linearity
±0.33
T A = 10°C or +50°C, +VS = 3.3V to
4.0V
±0.50
T A = −10 °C or +85°C, +VS = 3.3V
to 4.0V
±1.00
T A = +125°C, +VS = 4.0V
±1.25
T A = −25°C to 150°C, +VS = 4.0V
±1.50
13
0.0625
(5)
Offset Error of Transfer Function
Limits (2)
T A = +30°C, +VS = 3.3V to 4.0V
(4)
Resolution
Typical (1)
+VS = 4.0V
Offset Error of Transfer Function Supply
Sensitivity
2.7V ≤ +VS< 3.6V
°C/V (max)
3.6V ≤ +VS≤ 5.5V
°C/V (max)
500
2
Quiescent Current
°C (max)
°C (max)
(7)
Temperature Conversion Time
°C (max)
Bits
°C
±0.5
(6)
Unit
(Limit)
I C Inactive
0.35
I2C Active
0.35
Shutdown Mode
5
1000
ms
0.625
mA (max)
mA
µA
(8) (9)
°C
T LOW Default Temperature
(9)
10
°C
T HIGH Default Temperature
(9)
64
°C
T C Default Temperature
(9)
80
°C
T HYST Default Temperature
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
2
Typical values are at TA = 25 °C and represent most likely parametric norm.
Limits are guaranteed to TI's AOQL (Average Outgoing Quality Level).
The limits found in Table 1 supersede the limits shown in the Electrical Characteristics Table. The Accuracy specification includes errors
due to linearity, offset and gain. The accuracy specification includes effects of self heating with negligible digital output loading. Pull-up
resistors should be maximized (10k typical recommended), so that self heating due to digital output loading is negligible.
Limits at intermediate temperatures can be calculated using a straight line interpolation as shown in Figure 2 and Figure 3.
Linearity Error is defined as the worse case difference of an actual reading to that of a calculated reading derived from the straight line
whose endpoints are measured at 30°C and 125°C for the range of 30°C to 125°C or whose endpoints are measured at 30°C and
−25°C for the range of 30°C to −25°.
Offset Error calibration should be done at 30°C. The residual error of the transfer function is then equivalent to the Accuracy Limit minus
the Offset Limit. This does not take into account the power supply sensitivity of the offset error. Nor, does it take into account the error
introduced by the calibration system used.
This specification is provided only to indicate how often temperature data is updated. The LM92 can be read at any time without regard
to conversion state (and will yield last conversion result). If a conversion is in process it will be interrupted and restarted after the end of
the read.
12 bits + sign, two's complement
Default values set at power up.
Figure 2. Accuracy vs Temperature with +Vs = 5V
4
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
Figure 3. Accuracy vs Temperature with +Vs = 3.3V
Table 1. Temperature Accuracy Parameter Limits
Conditions
+VS=2.7V
+VS=3.3V
+VS=4V
+VS=5V
+VS=5.5V
Unit
T A = −25°C
−1.35/+1.50
−1.25/+1.50
−1.25/+1.50
−1.05/+1.70
−1.05/+1.80
°C (max)
T A = −10°C
±1.00
−0.90/+1.00
−0.90/+1.00
−0.70/+1.20
−0.70/+1.30
°C (max)
T A = 0°C
−0.80/+0.75
−0.70/+0.75
−0.70/+0.75
−0.50/+0.95
−0.50/+1.05
°C (max)
T A = 10°C
−0.60/+0.50
±0.50
±0.50
−0.30/+0.70
−0.30/+0.80
°C (max)
T A = 30°C
−0.43/+0.33
±0.33
±0.33
−0.13/+0.53
−0.13/+0.63
°C (max)
T A = 50°C
−0.60/+0.50
±0.50
±0.50
−0.30/+0.70
−0.30/+0.80
°C (max)
T A = 85°C
−1.10/+0.85
−1.00/+0.85
−1.00/+0.85
−0.80/+1.05
−0.80/+1.15
°C (max)
T A = 125°C
−1.60/+1.25
−1.50/+1.25
±1.25
−1.05/+1.45
−1.05/+1.55
°C (max)
T A = 150°C
±1.90
−1.75/+1.50
±1.50
−1.30/+1.70
−1.30/+1.80
°C (max)
Digital DC Characteristics
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ
= TMIN to TMAX; all other limits TA= TJ= +25 °C, unless otherwise noted.
Symbol
V IN(1)
V IN(0)
VIN(HYST)
V IN(1)
Parameter
Conditions
Typical (1)
SDA and SCL Logical “1” Input
Voltage
SDA and SCL Logical “0” Input
Voltage
SDA and SCL Digital Input Hysteresis
500
A0 and A1 Logical “1” Input Voltage
Limits (2)
Unit
(Limit)
+VS × 0.7
V (min)
+VS+0.3
V (max)
−0.3
V (min)
+VS × 0.3
V (max)
250
mV (min)
2.0
V (min)
+VS+0.3
V (max)
−0.3
V (min)
V IN(0)
A0 and A1 Logical “0” Input Voltage
0.7
V (max)
I IN(1)
Logical “1” Input Current
V IN = + VS
0.005
1.0
µA (max)
I IN(0)
Logical “0” Input Current
V IN = 0 V
−0.005
−1.0
µA (max)
C IN
Capacitance of All Digital Inputs
I OH
High Level Output Current
V OH = + VS
10
µA (max)
V OL
Low Level Output Voltage
I OL = 3 mA
0.4
V (max)
(1)
(2)
20
pF
Typical values are at TA = 25 °C and represent most likely parametric norm.
Limits are guaranteed to TI's AOQL (Average Outgoing Quality Level).
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
5
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
Digital DC Characteristics (continued)
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ
= TMIN to TMAX; all other limits TA= TJ= +25 °C, unless otherwise noted.
Symbol
Parameter
Conditions
T_CRIT_A Output Saturation Voltage
Typical (1)
I OUT = 4.0 mA
(3)
T_CRIT_A Delay
t OF
Limits (2)
Unit
(Limit)
0.8
V (max)
1
Output Fall Time
C L = 400 pF
Conversions
(max)
250
ns (max)
I O = 3 mA
(3)
For best accuracy, minimize output loading. 10k pull-ups resistors should be sufficient. Higher sink currents can affect sensor accuracy
with internal heating. This can cause an error of 0.64 °C at full rated sink current and saturation voltage based on junction-to-ambient
thermal resistance.
Serial Bus Digital Switching Characteristics
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ
= TMIN to TMAX; all other limits TA= TJ= +25 °C, unless otherwise noted. CL (load capacitance) on output lines = 80 pF unless
otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = +25 °C, unless otherwise noted.
Symbol
Parameter
Conditions
t1
SCL (Clock) Period
t2
Data in Set-Up Time to SCL High
t3
Data Out Stable after SCL Low
t4
t5
tTIMEOUT
SDA and SCL Time Low for Reset of Serial Interface
Typical (1)
Limits (2)
2.5
1
(1)
(2)
(3)
(4)
(3)
Unit
(Limit)
µs(min)
ms(max)
100
ns(min)
0
ns(min)
SDA Low Set-Up Time to SCL Low (Start Condition)
100
ns(min)
SDA High Hold Time after SCL High (Stop Condition)
100
ns(min)
75
300
ms (min)
ms (max)
(4)
Typical values are at TA = 25 °C and represent most likely parametric norm.
Limits are guaranteed to TI's AOQL (Average Outgoing Quality Level).
Timing specifications are tested at the bus input logic levels (Vin(0)=0.3xVA for a falling edge and Vin(1)=0.7xVA for a rising edge) when
the SCL and SDA edge rates are similar.
Holding the SDA and/or SCL lines Low for a time interval greater than tTIMEOUT will cause the LM92 to reset SCL and SDA to the IDLE
state of the serial bus communication (SDA and SCL set High).
Figure 4. Serial Bus Communication
6
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
Figure 5. Temperature-to-Digital Transfer Function (Non-linear scale for clarity)
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
7
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
FUNCTIONAL DESCRIPTION
The LM92 temperature sensor incorporates a band-gap type temperature sensor, 13-bit ADC, and a digital
comparator with user-programmable upper and lower limit values. The comparator activates either the INT line
for temperatures outside the TLOW and THIGH window, or the T_CRIT_A line for temperatures which exceed
T_CRIT. The lines are programmable for mode and polarity.
TEMPERATURE COMPARISON
LM92 provides a window comparison against a lower (TLOW) and upper (THIGH) trip point. A second upper trip
point (T_CRIT) functions as a critical alarm shutdown. Figure 7 depicts the comparison function as well as the
modes of operation.
Status Bits
The internal Status bits operate as follows:
“True”: Temperature above a THIGH or T_CRIT is “true” for those respective bits. A “true” for TLOW is
temperature below TLOW.
“False”: Assuming temperature has previously crossed above THIGH or T_CRIT, then the temperature must
drop below the points corresponding THYST (THIGH − THYST or T_CRIT − THYST) in order for the condition to be
false. For TLOW, assuming temperature has previously crossed below TLOW, a “false” occurs when temperature
goes above TLOW + THYST.
The Status bits are not affected by reads or any other actions, and always represent the state of temperature vs.
setpoints.
Hardwire Outputs
The T_CRIT_A hardwire output mirrors the T_CRIT_A flag, when the flag is true, the T_CRIT_A output is
asserted at all times regardless of mode. Reading the LM92 has no effect on the T_CRIT_A output, although the
internal conversion is restarted.
The behavior of the INT hardwire output is as follows:
Comparator Interrupt Mode (Default): User reading part resets output until next measurement completes. If
condition is still true, output is set again at end of next conversion cycle. For example, if a user never reads the
part, and temperature goes below TLOW then INT becomes active. It would stay that way until temperature goes
above TLOW + THYST. However if the user reads the part, the output would be reset. At the end of the next
conversion cycle, if the condition is true, it is set again. If not, it remains reset.
Event Interrupt Mode: User reading part resets output until next condition "event" occurs (in other words,
output is only set once for a true condition, if reset by a read, it remains reset until the next triggering threshold
has been crossed). Conversely, if a user never read the part, the output would stay set indefinitely after the first
event that set the output. An “event” for Event Interrupt Mode is defined as:
1. Transitioning upward across a setpoint, or
2. Transitioning downward across a setpoint's corresponding hysteresis (after having exceeded that setpoint).
For example, if a user never read the part, and temperature went below TLOW then INT would become active. It
would stay that way forever if a user never read the part.
However if the user read the part, the output would be reset. Even if the condition is true, it will remain reset. The
temperature must cross above TLOW + THYST to set the output again.
In either mode, reading any register in the LM92 restarts the conversion. This allows a designer to know exactly
when the LM92 begins a comparison. This prevents unnecessary Interrupts just after reprogramming setpoints.
Typically, system Interrupt inputs are masked prior to reprogramming trip points. By doing a read just after
resetting trip points, but prior to unmasking, unexpected Interrupts are prevented.
Avoid programming setpoints so close that their hysteresis values overlap. An example would be that with a
THYST value of 2 °C then setting THIGH and TLOW to within 4 °C of each other will violate this restriction. To be
more specific, with THYST set to 2 °C assume THIGH set to 64 °C. If TLOW is set equal to, or higher than 60 °C this
restriction is violated.
8
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
DEFAULT SETTINGS
The LM92 always powers up in a known state. LM92 power up default conditions are:
1. Comparator Interrupt Mode
2. TLOW set to 10 °C
3. THIGH set to 64 °C
4. T_CRIT set to 80 °C
5. THYST set to 2 °C
6. INT and T_CRIT_A active low
7. Pointer set to “00”; Temperature Register
The LM92 registers will always reset to these default values when the power supply voltage is brought up from
zero volts as the supply crosses the voltage level plotted in the following curve. The LM92 registers will reset
again when the power supply drops below the voltage plotted in this curve.
Figure 6. Average Power on Reset Voltage vs Temperature
SERIAL BUS INTERFACE
The LM92 operates as a slave on the Serial Bus, so the SCL line is an input (no clock is generated by the LM92)
and the SDA line is a bi-directional serial data line. According to Serial Bus specifications, the LM92 has a 7-bit
slave address. The five most significant bits of the slave address are hard wired inside the LM92 and are
“10010”. The two least significant bits of the address are assigned to pins A1–A0, and are set by connecting
these pins to ground for a low, (0); or to +VS for a high, (1).
Therefore, the complete slave address is:
1
0
0
1
MSB
0
A1
A0
LSB
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
9
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn't read, the outputs would go
low and stay that way until the LM92 is read. Comparator Interrupt Mode is drawn as if the user never reads the part.
If the user does read, the outputs will go high once read instruction is executed and, if the fault condition still exists,
go low at the end of the next conversion.
Figure 7. Temperature Response Diagram
TEMPERATURE DATA FORMAT
Temperature data can be read from the Temperature and Set Point registers; and written to the Set Point
registers. Temperature data can be read at any time, although reading faster than the conversion time of the
LM92 will prevent data from being updated. Temperature data is represented by a 13-bit, two's complement word
with an LSB (Least Significant Bit) equal to 0.0625 °C:
Table 2. Temperature Data Output
Temperature
Digital Output
Binary
10
Hex
+130°C
0 1000 0 010 0000
08 20h
+125 °C
0 0111 1101 0000
07 D0h
+80 °C
0 0101 0000 0000
05 00h
+64 °C
0 0100 0000 0000
04 00h
+25 °C
0 0001 1001 0000
01 90h
+10 °C
0 0000 1010 0000
00 A0h
+2 °C
0 0000 0010 0000
00 20h
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
Table 2. Temperature Data Output (continued)
Temperature
Digital Output
Binary
Hex
+0.0625 °C
0 0000 0000 0001
00 01h
0 °C
00 0000 0000
00 00h
−0.0625 °C
1 1111 1111 1111
1F FFh
−25 °C
1 1110 0111 0000
1E 70h
−55 °C
1 1100 1001 0000
1C 90h
SHUTDOWN MODE
Shutdown mode is enabled by setting the shutdown bit in the Configuration register via the Serial Bus. Shutdown
mode reduces power supply current to 5 µA typical. T_CRIT_A is reset if previously set. Since conversions are
stopped during shutdown, T_CRIT_A and INT will not be operational. The Serial Bus interface remains active.
Activity on the clock and data lines of the Serial Bus may slightly increase shutdown mode quiescent current.
Registers can be read from and written to in shutdown mode. The LM92 takes milliseconds to respond to the
shutdown command.
INT AND T_CRIT_A OUTPUT
The INT and T_CRIT_A outputs are open-drain outputs and do not have internal pull-ups. A "high" level will not
be observed on these pins until pull-up current is provided from some external source, typically a pull-up resistor.
Choice of resistor value depends on many system factors but, in general, the pull-up resistor should be as large
as possible. This will minimize any errors due to internal heating of the LM92. The maximum resistance of the
pull up, based on LM92 specification for High Level Output Current, to provide a 2 volt high level, is 30K ohms.
FAULT QUEUE
A fault queue of 4 faults is provided to prevent false tripping when the LM92 is used in noisy environments. The 4
faults must occur consecutively to set flags as well as INT and T_CRIT_A outputs. The fault queue is enabled by
setting bit 4 of the Configuration Register high (see CONFIGURATION REGISTER ).
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
11
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
INTERNAL REGISTER STRUCTURE
Figure 8.
There are four data registers in the LM92, selected by the Pointer register. At power-up the Pointer is set to “00”;
the location for the Temperature Register. The Pointer register latches the last location it was set to. In Interrupt
Mode, a read from the LM92 resets the INT output. Placing the device in Shutdown mode resets the INT and
T_CRIT_A outputs. All registers are read and write, except the Temperature register which is read only.
A write to the LM92 will always include the address byte and the Pointer byte. A write to the Configuration
register requires one data byte, while the TLOW, THIGH, and T_CRIT registers require two data bytes.
Reading the LM92 can take place either of two ways: If the location latched in the Pointer is correct (most of the
time it is expected that the Pointer will point to the Temperature register because it will be the data most
frequently read from the LM92), then the read can simply consist of an address byte, followed by retrieving the
corresponding number of data bytes. If the Pointer needs to be set, then an address byte, pointer byte, repeat
start, and another address byte plus required number of data bytes will accomplish a read.
The first data byte is the most significant byte with most significant bit first, permitting only as much data as
necessary to be read to determine the temperature condition. For instance, if the first four bits of the temperature
data indicates a critical condition, the host processor could immediately take action to remedy the excessive
temperature. At the end of a read, the LM92 can accept either Acknowledge or No Acknowledge from the Master
(No Acknowledge is typically used as a signal for the slave that the Master has read its last byte).
An inadvertent 8-bit read from a 16-bit register, with the D7 bit low, can cause the LM92 to stop in a state where
the SDA line is held low as shown in Figure 9. This can prevent any further bus communication until at least 9
additional clock cycles have occurred. Alternatively, the master can issue clock cycles until SDA goes high, at
which time issuing a “Stop” condition will reset the LM92.
12
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
Figure 9. Inadvertent 8-Bit Read from 16-Bit Register where D7 is Zero (“0”)
POINTER REGISTER
(Selects which registers will be read from or written to):
P7
P6
P5
P4
P3
0
0
0
0
0
P2
P1
P0
Register Select
P0–P2: Register Select:
P2
P1
P0
0
0
0
Temperature (Read only) (Power-up default)
Register
0
0
1
Configuration (Read/Write)
0
1
0
THYST (Read/Write)
0
1
1
T_CRIT (Read/Write)
1
0
0
TLOW (Read/Write)
1
0
1
THIGH (Read/Write)
1
1
1
Manufacturer's ID
P3–P7: Must be kept zero.
TEMPERATURE REGISTER
Table 3. (Read Only):
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
Sign
MSB
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
CRIT
D1
D0
HIGH
LOW
Status Bits
D0–D2: Status Bits
D3–D15: Temperature Data. One LSB = 0.0625°C. Two's complement format.
CONFIGURATION REGISTER
Table 4. (Read/Write):
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
Fault Queue
INT Polarity
T_CRIT_A
Polarity
INT Mode
Shutdown
D0: Shutdown - When set to 1 the LM92 goes to low power shutdown mode. Power up default of “0”.
D1: Interrupt mode - 0 is Comparator Interrupt mode, 1 is Event Interrupt mode. Power up default of “0”.
D2, D3: T_CRIT_A and INT Polarity - 0 is active low, 1 is active high. Outputs are open-drain. Power up default
of “0”
D4: Fault Queue - When set to 1 the Fault Queue is enabled, see FAULT QUEUE. Power up default of “0”.
D5–D7: These bits are used for production testing and must be kept zero for normal operation.
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
13
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
THYST, TLOW, THIGH AND T_CRIT_A REGISTERS
Table 5. (Read/Write):
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Sign
MSB
Bit 10
Bit 9
Bit 8
Bit7
Bit6
Bit5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
X
X
X
D0–D2: Undefined
D3–D15: THYST, TLOW, THIGH or T_CRIT Trip Temperature Data. Power up default is TLOW = 10°C, THIGH = 64°C,
T_CRIT = 80°C, THYST = 2°C.
THYST is subtracted from THIGH, and T_CRIT, and added to TLOW.
Avoid programming setpoints so close that their hysteresis values overlap. See TEMPERATURE COMPARISON.
Manufacturer's Identification Register
Table 6. (Read only):
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
D0–D15: Manufactures ID.
14
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
I2C TIMING DIAGRAMS
Figure 10. Typical 2-Byte Read From Preset Pointer Location Such as Temp or Comparison Registers
Figure 11. Typical Pointer Set Followed by Immediate Read for 2-Byte Register such as Temp or
Comparison Registers
Figure 12. Typical 1-Byte Read from Configuration Register with Preset Pointer
Figure 13. Typical Pointer Set Followed by Immediate Read from Configuration Register
Figure 14. Configuration Register Write
Figure 15. Comparison Register Write
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
15
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
APPLICATION HINTS
The temperature response graph in Figure 16 depicts a typical application designed to meet ACPI requirements.
In this type of application, the temperature scale is given an arbitrary value of "granularity", or the window within
which temperature notification events should occur. The LM92 can be programmed to the window size chosen by
the designer, and will issue interrupts to the processor whenever the window limits have been crossed. The
internal flags permit quick determination of whether the temperature is rising or falling.
The T_CRIT limit would typically use its separate output to activate hardware shutdown circuitry separate from
the processor. This is done because it is expected that if temperature has gotten this high that the processor may
not be responding. The separate circuitry can then shut down the system, usually by shutting down the power
supply.
Note that the INT and T_CRIT_A outputs are separate, but can be wire-ORed together. Alternatively the
T_CRIT_A can be diode ORed to the INT line in such a way that a T_CRIT_A event activates the INT line, but an
INT event does not activate the T_CRIT_A line. This may be useful in the event that it is desirable to notify both
the processor and separate T_CRIT_A shutdown circuitry of a critical temperature alarm at the same time
(maybe the processor is still working and can coordinate a graceful shutdown with the separate shutdown
circuit).
To implement ACPI compatible sensing it is necessary to sense whenever the temperature goes outside the
window, issue an interrupt, service the interrupt, and reprogram the window according to the desired granularity
of the temperature scale. The reprogrammed window will now have the current temperature inside it, ready to
issue an interrupt whenever the temperature deviates from the current window.
To understand this graph, assume that at the left hand side the system is at some nominal temperature. For the
1st event temperature rises above the upper window limit, THIGH, causing INT to go active. The system responds
to the interrupt by querying the LM92's status bits and determines that THIGH was exceeded, indicating that
temperature is rising. The system then programs the temperature limits to a value higher by an amount equal to
the desired granularity. Note that in Event Interrupt Mode, reprogramming the limits has caused a second,
known, interrupt to be issued since temperature has been returned within the window. In Comparator Interrupt
Mode, the LM92 simply stops issuing interrupts.
The 2nd event is another identical rise in temperature. The 3rd event is typical of a drop in temperature. This is
one of the conditions that demonstrates the power of the LM92, as the user receives notification that a lower limit
is exceeded in such a way that temperature is dropping.
The Critical Alarm Event activates the separate T_CRIT_A output. Typically, this would feed circuitry separate
from the processor on the assumption that if the system reached this temperature, the processor might not be
responding.
16
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn't read, the outputs would go
low and stay that way until the LM92 is read.
Figure 16. Temperature Response Diagram for ACPI Implementation
Typical Applications
Figure 17. Typical Application
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
17
LM92
SNIS110D – MARCH 2000 – REVISED MARCH 2013
www.ti.com
Figure 18. Remote HVAC temperature sensor communicates via 3 wires, including thermostat signals
Figure 19. ACPI Compatible Terminal Alarm Shutdown
By powering the LM92 from auxiliary output of the power supply, a non-functioning overheated computer can be
powered down to preserve as much of the system as possible.
18
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
LM92
www.ti.com
SNIS110D – MARCH 2000 – REVISED MARCH 2013
REVISION HISTORY
Changes from Revision C (March 2013) to Revision D
•
Page
Changed layout of National Data Sheet to TI format .......................................................................................................... 18
Submit Documentation Feedback
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM92
19
PACKAGE OPTION ADDENDUM
www.ti.com
1-Nov-2013
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
MSL Peak Temp
(2)
(6)
(3)
Op Temp (°C)
Device Marking
(4/5)
LM92CIM
NRND
SOIC
D
8
95
TBD
Call TI
Call TI
-55 to 150
LM92
CIM
LM92CIM/NOPB
ACTIVE
SOIC
D
8
95
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
-55 to 150
LM92
CIM
LM92CIMX
NRND
SOIC
D
8
2500
TBD
Call TI
Call TI
-55 to 150
LM92
CIM
LM92CIMX/NOPB
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
-55 to 150
LM92
CIM
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5)
Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6)
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Addendum-Page 1
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
1-Nov-2013
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
26-Mar-2013
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
LM92CIMX
SOIC
D
8
2500
330.0
12.4
6.5
5.4
2.0
8.0
12.0
Q1
LM92CIMX/NOPB
SOIC
D
8
2500
330.0
12.4
6.5
5.4
2.0
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
26-Mar-2013
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
LM92CIMX
SOIC
D
8
2500
367.0
367.0
35.0
LM92CIMX/NOPB
SOIC
D
8
2500
367.0
367.0
35.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated
Similar pages