EB100 High Accuracy Miniature Pressure Transducer SPECIFICATIONS Ranges from 20 to 350 bar (300 to 5,000 psi) Operating temperature up to 125 °C (257 °F) ±0.25% Miniature Design and Light Weight ±1% Total Error Band Available male threads such as : M5x0.8 10-32 UNF M8x1 5/16-24 UNF 0.5 to 4.5V amplified output The EB100 uses TE’s UltraStable technology that provides stability over a wide temperature range and performance previously available only in much higher priced sensors. The UltraStable technology employs a silicon-based strain gage, isolated from the media by an oil-filled capsule and a stainless steel diaphragm. The high stability offers excellent repeatability and minimal hysteresis. APPLICATIONS Combined errors of linearity, hysteresis & repeatability The EB100 pressure transducer is the smallest design proposed by TE Connectivity from the UltraStable line. It sets a new price / performance standard for demanding commercial and heavy industrial applications where high accuracy, small size and low weight are desirable. This series is suitable for measurement of liquid or gas pressure, including difficult media such as contaminated water, steam, and mildly corrosive fluids. FEATURES Unique pressure reference version Absolute Motor Sport: Oil, Coolant, Fuel, Brake Systems Hydraulic/Pneumatic Systems Automotive Test Stands Military/Aerospace Test Stands The 100% stainless steel media isolation covers all but the most corrosive environments, offering excellent durability. Custom OEM designs are available including various ports and output options. On request, Instruction documents can be provided to ease the selection and use of our sensors and provide helpful tips. SENSOR SOLUTIONS ///EB100_en 08/2016 Page 1 EB100 High Accuracy Miniature Pressure Transducer STANDARD RANGES Ranges (FS) bar psi 20 300 35 500 70 1K 100 1.5K 200 3K 350 5K Pressure Reference Pressure Overload (rated pressure) Burst Pressure (rated pressure) 2 x FS 3 x FS 2 x FS 3 x FS 2 x FS 3 x FS 2 x FS 3 x FS 2 x FS 3 x FS 2 x FS 3 x FS abs. (type3) PERFORMANCE SPECIFICATIONS (typical values at temperature 23±3°C) PARAMETERS VALUES NOTES Combined Non-Linearity, Hysteresis, and Repeatability ±0.25 %FS Long Term Stability (1 year) ±0.1 %FS Total Error Band (TEB over CTR) ±1 %FS Bandwidth (-3 dB) 120 Hz Isolation resistance @50Vdc 50 MΩ Compensated Temperature Range (CTR) -20 to +125 °C (-4 to+257 F) Operating Temperature Range (OTR) -40 to +125 °C (-40 to +257 F) Storage Temperature -40 to +125 °C (-40 to +257 F) Vibration (20 to 200Hz) 20 g 3 Shock (11ms) 50 g 4 Pressure Cycles (Zero to Full Scale) 1 Million Weight (without cable) 15 grams +21 grams per meter of cable Ingress Protection IP66 Media Compatibility Fluids compatible with 17-4PH, 316 S.S. and FKM Fluoroelastomer 1 2 Notes 1. Best fit straight line for all pressure ranges except for 200 bar (3 kpsi) = +/-0.35% and 350 bar (5 kpsi) = +/-0.5%. 2. TEB includes all accuracy errors, thermal errors, span and zero tolerances. 3. Per MIL-STD-810C, Procedure 514.2, Figure 514.2-2, Curve L. 4. 1/2 sine per MIL-STD 202F Method 213B condition A. CE compliance IEC 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (2kV contact/2kV air) IEC 61000-4-3 EM Field Immunity (3V/m) IEC 61000-4-4 Electrical Fast Transient Immunity (0.5kV) IEC 61000-4-6 Conducted Immunity (3V) SUPPLY VOLTAGE ELECTRICAL CONNECTION OPTIONS (table 1) Code Supply voltage Signal Code Connection U 8 to 30 V (current < 5 mA) 0.5 – 4.5 V M 1 metre of shielded cable (PFA) P 5 metres of shielded cable (PFA) R 10 metres of shielded cable (PFA) S 1 metre of shielded cable (PFA) fully covered by shrink tube model Raychem DR25 or equivalent SENSOR SOLUTIONS ///EB100_en 08/2016 Page 2 EB100 High Accuracy Miniature Pressure Transducer DIMENSIONS PHYSICAL (table 2) Model Pressure port Length "C" Hex."D" O-ring supplied Installation torque max N M5x0.8 6.6 (.26”) 11 (.433") Ø3.5x1.5 FKM Fluoroelastomer 1 Nm (9 In-Pounds) V 10-32 UNF-2A 6.6 (.26”) 11 (.433") Ø3.5x1.5 FKM Fluoroelastomer 1 Nm (9 In-Pounds) S M8X1 7.6 (.30”) 11 (.433") Ø6.07x1.63 FKM Fluoroelastomer 3 Nm (27 In-Pounds) Q 5/16-24 UNF-2A 7.6 (.30”) 11 (.433") Ø6.07x1.63 FKM Fluoroelastomer 3 Nm (27 In-Pounds) P M10x1 8.2 (.32") 13 (.512") Ø7.65x1.63 FKM Fluoroelastomer 5 Nm (27 In-Pounds) X 3/8-24 UNF-2A 8.2 (.32") 13 (.512") Ø7.65x1.63 FKM Fluoroelastomer 5 Nm (27 In-Pounds) INSTALLATION & CONNECTION RECOMMENDED PRESSURE FITTING DESIGN (1) Thread "A" Dim. “B” Dim. “C” Dim. “D” M5x0.8(2) 6.35 mm 1.5 mm 0.2 mm 0.25” 0.059” 0.008” M8x1 9.1 mm 1.9 mm 0.3 mm 5/16-24 UNF-2A 0.358” 0.074” 0.012” 10.7 mm 1.9 mm 0.3 mm 10-32 UNF(2) M10x1 3/8-24 UNF-2A 0.421" 0.074” 0.012” 1. Tolerances on dimensions = ± 0.05 mm (0.002”) This pressure fitting design is only a recommendation but it stays under customer's responsibility. 2. For model M5x0.8 or 10-32 UNF used with pressure higher than 200 bar (3k psi) it is recommended to replace O-ring by bonded ring (ref: MSE05417) and to design the pressure fitting without O-ring chamber. WIRING: SHIELDED CABLE 4 LEADS AWG26 RED +SUPPLY GREEN +OUTPUT WHITE -OUTPUT BLACK -SUPPLY The shield is not connected to sensor’s body. SENSOR SOLUTIONS ///EB100_en 08/2016 Page 3 EB100 High Accuracy Miniature Pressure Transducer ORDERING INFORMATION EB1 U M - 0000 1 5 - 100B G Model Supply Voltage Connection Type - 0000 Calibration Certificate Pressure Port - Pressure Range Pressure Type M = 1 Meter Cable P = 5 Meter Cable R = 10 Meter Cable S = 1 Meter Cable fully covered by shrink tube Raychem DR25 or equivalent - 0 = No calibration certificate 1 = With calibration certificate S = M8x1 Q = 5/16-24 UNF N = M5x0.8 V = 10-32 UNF Male P = M10x1 Male X = 3/8-24 UNF Male EB1 U = 8 to 30V - 300P 500P 01KP 1K5P 03KP 05KP 020B 035B 070B 100B 200B 350B A = Absolute The psi range models are only supplied with imperial thread design. The bar range models are only supplied with metric thread design. NORTH AMERICA EUROPE ASIA Measurement Specialties, Inc., a TE Connectivity company 45738 Northport Loop West Fremont, CA 94538 Tel: +1 800 767 1888 Fax: +1 510 498 1578 [email protected] MEAS France SAS, a TE Connectivity company 4 Rue Gaye Marie 31027 Toulouse, France Tel: +33 (5) 822 822 00 Fax: +33 (5) 820 821 51 [email protected] Measurement Specialties (China) Ltd., a TE Connectivity company No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen, 518057 China Tel: +86 755 3330 5088 Fax: +86 755 3330 5099 [email protected] TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2015 TE Connectivity Ltd. family of companies SENSOR SOLUTIONS ///EB100_en All Rights Reserved. 08/2016 Page 4