NI NIPCI-6511 Low-cost industrial digital i/o-30 v, bank isolated Datasheet

Low-Cost Industrial Digital I/O – 30 V, Bank Isolated
NI 651x
• 32- or 64-bank optically isolated inputs
and outputs (±30 VDC)
• High-reliability industrial feature set –
isolation, programmable power-up
states, digital I/O watchdogs, change
detection, programmable input filters
• Low-cost solution with superior features
for data acquisition, manufacturing test,
and industrial control applications
• Direct connection to industrial
sensors and actuators
• NI-DAQmx software for highest
productivity and performance
Operating Systems
• Windows Vista (32- and 64-bit)/XP/2000
• LabVIEW Real-Time
Recommended Software
• LabVIEW
• LabWindows™/CVI
• Measurement Studio
Other Compatible Software
• ANSI C, C++
• Microsoft Visual Studio .NET 2003
Measurement Services
Software (included)
• NI-DAQmx
Product
NI 6510
NI 6511
NI 6512
NI 6513
NI 6514
NI 6515
NI 6516
NI 6517
NI 6518
NI 6519
Bus
PCI
PCI, PXI
PCI, PXI
PCI, PXI
PCI, PXI
PCI, PXI
PCI
PCI
PCI
PCI
Input Lines
32 source/sink
64 source/sink
–
–
32 source/sink
32 source/sink
–
–
16 source/sink
16 source/sink
Output Lines
–
–
64 source
64 sink
32 source
32 sink
32 source
32 sink
16 source
16 sink
Isolation
Bank
Bank
Bank
Bank
Bank
Bank
Bank
Bank
Bank
Bank
Max Range (VDC)
±30
±30
±30
±30
±30
±30
±30
±30
±30
±30
Low Thresh (VDC)
±4
±4
–
–
±4
±4
–
–
±4
±4
High Thresh (VDC)
±11
±11
–
–
±11
±11
–
–
±11
±11
Output Current (mA)1 Industrial Feature Set
–
3
–
3
350 (75)
3
500 (120)
3
350 (75)
3
500 (120)
3
350 (75)
3
500 (120)
3
350 (75)
3
500 (120)
3
1When using all lines at a 100 percent duty cycle, the maximum drive current for NI 6512 and NI 6514 devices is 75 mA, and 120 mA for NI 6513 and NI 6515 devices. When using only one output line in each bank at a 100 percent duty cycle, the maximum drive current for NI 6512 and NI 6514 devices is 350 mA, and 500 mA for NI 6513 and NI 6515 devices.
Table 1. NI 651x Selection Guide
Overview and Applications
NI 651x devices are industrial 32- or 64-channel isolated digital I/O
interfaces for PCI and PXI/CompactPCI systems. You can wire each input
bank in a source or sink configuration and input and output at digital
levels up to ±30 VDC with high current switching capability. NI 651x
devices are ideal for general-purpose data acquisition applications as
well as industrial control and automated manufacturing test. With high
current drive and isolation, you can connect the digital I/O directly to a
wide array of 24 V electronic devices, sensors, and actuators.
NI 651x devices offer superior features and high value for industrial
control and manufacturing test applications such as factory automation,
embedded machine control, and production line verification. These devices
have been designed to incorporate the latest hardware technologies and
provide innovative features for applications requiring ease of use, high
reliability, and performance. NI 651x devices take advantage of NI-DAQmx
software, which includes technology to speed up application development
with many helpful features including the DAQ Assistant, automatic code
generation, and high-performance multithreaded streaming technology.
Hardware
High-Reliability Industrial Feature Set
NI 651x devices offer a set of high-reliability features designed to
automate even the most demanding applications:
• Isolation provides an extended voltage range and direct connection
to industrial sensors and actuators
• Programmable power-up states offer safe operation when connected
to pumps/valves/motors/relays
• Digital I/O watchdogs detect computer or application errors and
ensure safe recovery
• Change detection triggers your application and returns I/O data
after a digital event with minimal processor usage
• Programmable input filters eliminate glitches/spikes and remove noise
Low-Cost Industrial Digital I/O – 30 V, Bank Isolated
Connect Sensors Directly with Isolation
Isolation is a form of built-in signal conditioning that provides several
advantages, such as an extended voltage range and direct connection
to industrial sensors and actuators. Isolation also improves signal quality
and protects computer circuitry. It physically and electrically separates
two parts of a circuit, which breaks ground loops, improves common-mode
voltage and noise rejection, and permits the two parts of the circuit to be
at different voltage levels. Many industrial applications require isolation
to protect the electronics from transient voltage spikes and provide greater
common-mode noise rejection in electrically noisy environments containing
machinery and inductive loads. In bank-to-bank isolated devices, such as an
NI 651x, each bank (or group) of several channels shares the same ground
but is isolated from other banks.
CPLD
PCI/PXI Bus
100-Pin SCSI I/O Connector
Voltage
Darlington Arrays
With programmable power-up states, you can configure the initial output
states of the digital I/O device in software to ensure glitch-free operations
when connected to industrial actuators such as pumps, valves, motors,
and relays. The digital I/O device holds these I/O states after receiving
power, so your computer can boot and your software application can
begin running. Programmable power-up states are glitch-free, meaning
the outputs never go through an incorrect state during power up.
You can configure each digital line as high-output or low-output. The
digital I/O device stores the settings in onboard nonvolatile memory and
implements the power-up states automatically after power is applied to
the device.
Detect and Recover with Digital I/O Watchdogs
Oscillator
Voltage
Glitch-Free Startup with Programmable
Power-Up States
Photocouplers
MiniMITE 1
FPGA
Photocouplers
NI digital I/O watchdogs provide protection against a wide variety
of fault conditions:
• Computer crash – total OS crash
• Application crash – software application ceases to respond
• Driver crash – device driver ceases to respond
• PCI bus failure – communications cease to respond
Bus Switch
Flash
Figure 1. NI 651x Hardware Block Diagram
P0.0
P0.2
P0.4
P0.6
COM
P1.1
P1.3
P1.5
P1.7
P2.0
P2.2
P2.4
P2.6
COM
P3.1
P3.3
P3.5
P3.7
COM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NI 6510
P0.1
P0.3
P0.5
P0.7
P1.0
P1.2
P1.4
P1.6
COM
P2.1
P2.3
P2.5
P2.7
P3.0
P3.2
P3.4
P3.6
COM
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
P0.COM
P0.COM
P0.COM
P0.COM
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P2.7
P2.COM
P2.COM
P2.COM
P2.COM
NC
P4.0
P4.1
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7
P4.COM
P4.COM
P4.COM
P4.COM
P6.0
P6.1
P6.2
P6.3
P6.4
P6.5
P6.6
P6.7
P6.COM
P6.COM
P6.COM
P6.COM
NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P1.7
P1.COM
P1.COM
P1.COM
P1.COM
P3.0
P3.1
P3.2
P3.3
P3.4
P3.5
P3.6
P3.7
P3.COM
P3.COM
P3.COM
P3.COM
NC
P5.0
P5.1
P5.2
P5.3
P5.4
P5.5
P5.6
P5.7
P5.COM
P5.COM
P5.COM
P5.COM
P7.0
P7.1
P7.2
P7.3
P7.4
P7.5
P7.6
P7.7
P7.COM
P7.COM
P7.COM
P7.COM
NC
NI 6511
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
P0.COM (P0.GND)
P0.VCC
P0.VCC
P0.VCC
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P2.7
P2.COM (P2.GND)
P2.VCC
P2.VCC
P2.VCC
NC
P4.0
P4.1
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7
P4.COM (P4.GND)
P4.VCC
P4.VCC
P4.VCC
P6.0
P6.1
P6.2
P6.3
P6.4
P6.5
P6.6
P6.7
P6.COM (P6.GND)
P6.VCC
P6.VCC
P6.VCC
P6.+5V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
NI 6512
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P1.7
P1.COM (P1.GND)
P1.VCC
P1.VCC
P1.VCC
P3.0
P3.1
P3.2
P3.3
P3.4
P3.5
P3.6
P3.7
P3.COM (P3.GND)
P3.VCC
P3.VCC
P3.VCC
NC
P5.0
P5.1
P5.2
P5.3
P5.4
P5.5
P5.6
P5.7
P5.COM (P5.GND)
P5.VCC
P5.VCC
P5.VCC
P7.0
P7.1
P7.2
P7.3
P7.4
P7.5
P7.6
P7.7
P7.COM (P7.GND)
P7.VCC
P7.VCC
P7.VCC
P7.+5V
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
P0.COM (P0.VCC)
P0.GND
P0.GND
P0.GND
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P2.7
P2.COM (P2.VCC)
P2.GND
P2.GND
P2.GND
NC
P4.0
P4.1
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7
P4.COM (P4.VCC)
P4.GND
P4.GND
P4.GND
P6.0
P6.1
P6.2
P6.3
P6.4
P6.5
P6.6
P6.7
P6.COM (P6.VCC)
P6.GND
P6.GND
P6.GND
P6.+5V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
NI 6513
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P1.7
P1.COM (P1.VCC)
P1.GND
P1.GND
P1.GND
P3.0
P3.1
P3.2
P3.3
P3.4
P3.5
P3.6
P3.7
P3.COM (P3.VCC)
P3.GND
P3.GND
P3.GND
NC
P5.0
P5.1
P5.2
P5.3
P5.4
P5.5
P5.6
P5.7
P5.COM (P5.VCC)
P5.GND
P5.GND
P5.GND
P7.0
P7.1
P7.2
P7.3
P7.4
P7.5
P7.6
P7.7
P7.COM (P7.VCC)
P7.GND
P7.GND
P7.GND
P7.+5V
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
P0.COM
P0.COM
P0.COM
P0.COM
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P2.7
P2.COM
P2.COM
P2.COM
P2.COM
NC
P4.0
P4.1
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7
P4.COM (P4.GND)
P4.VCC
P4.VCC
P4.VCC
P6.0
P6.1
P6.2
P6.3
P6.4
P6.5
P6.6
P6.7
P6.COM (P6.GND)
P6.VCC
P6.VCC
P6.VCC
P6.+5V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P1.7
P1.COM
P1.COM
P1.COM
P1.COM
P3.0
P3.1
P3.2
P3.3
P3.4
P3.5
P3.6
P3.7
P3.COM
P3.COM
P3.COM
P3.COM
NC
P5.0
P5.1
P5.2
P5.3
P5.4
P5.5
P5.6
P5.7
P5.COM (P5.GND)
P5.VCC
P5.VCC
P5.VCC
P7.0
P7.1
P7.2
P7.3
P7.4
P7.5
P7.6
P7.7
P7.COM (P7.GND)
P7.VCC
P7.VCC
P7.VCC
P7.+5V
NI 6514
Figure 2. NI 6510, NI 6511, NI 6512, NI 6513, and NI 6514 Connectors
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
Low-Cost Industrial Digital I/O – 30 V, Bank Isolated
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
P0.COM
P0.COM
P0.COM
P0.COM
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P2.7
P2.COM
P2.COM
P2.COM
P2.COM
NC
P4.0
P4.1
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7
P4.COM (P4.VCC)
P4.GND
P4.GND
P4.GND
P6.0
P6.1
P6.2
P6.3
P6.4
P6.5
P6.6
P6.7
P6.COM (P6.VCC)
P6.GND
P6.GND
P6.GND
P6.+5V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
NI 6515
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P1.7
P1.COM
P1.COM
P1.COM
P1.COM
P3.0
P3.1
P3.2
P3.3
P3.4
P3.5
P3.6
P3.7
P3.COM
P3.COM
P3.COM
P3.COM
NC
P5.0
P5.1
P5.2
P5.3
P5.4
P5.5
P5.6
P5.7
P5.COM (P5.VCC)
P5.GND
P5.GND
P5.GND
P7.0
P7.1
P7.2
P7.3
P7.4
P7.5
P7.6
P7.7
P7.COM (P7.VCC)
P7.GND
P7.GND
P7.GND
P7.+5V
P0.0
P0.2
P0.4
P0.6
VCC
P1.1
P1.3
P1.5
P1.7
P2.0
P2.2
P2.4
P2.6
VCC
P3.1
P3.3
P3.5
P3.7
COM (GND)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
P0.1
P0.3
P0.5
P0.7
P1.0
P1.2
P1.4
P1.6
VCC
P2.1
P2.3
P2.5
P2.7
P3.0
P3.2
P3.4
P3.6
VCC
P0.0
P0.2
P0.4
P0.6
GND
P1.1
P1.3
P1.5
P1.7
P2.0
P2.2
P2.4
P2.6
GND
P3.1
P3.3
P3.5
P3.7
COM (VCC)
NI 6516
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NI 6517
P0.1
P0.3
P0.5
P0.7
P1.0
P1.2
P1.4
P1.6
GND
P2.1
P2.3
P2.5
P2.7
P3.0
P3.2
P3.4
P3.6
GND
P0.0
P0.2
P0.4
P0.6
P1.0
P1.2
P1.4
P1.6
IN.COM
VCC
P2.0
P2.2
P2.4
P2.6
P3.0
P3.2
P3.4
P3.6
OUT.COM (GND)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NI 6518
P0.1
P0.3
P0.5
P0.7
P1.1
P1.3
P1.5
P1.7
VCC
VCC
P2.1
P2.3
P2.5
P2.7
P3.1
P3.3
P3.5
P3.7
P0.0
P0.2
P0.4
P0.6
P1.0
P1.2
P1.4
P1.6
IN.COM
GND
P2.0
P2.2
P2.4
P2.6
P3.0
P3.2
P3.4
P3.6
OUT.COM (VCC)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
P0.1
P0.3
P0.5
P0.7
P1.1
P1.3
P1.5
P1.7
GND
GND
P2.1
P2.3
P2.5
P2.7
P3.1
P3.3
P3.5
P3.7
NI 6519
Figure 3. NI 6515, NI 6516, NI 6517, NI 6518, and NI 6519 SCSI I/O Connectors
With watchdogs, the digital outputs go to a safe recovery state when
a fault condition is detected and the watchdog timer expires. Watchdogs
are important whenever the device is connected to actuators such as
pumps, valves, motors, and relays. The digital I/O device monitors the
software application, and if the application fails to respond within the time
limit, the device automatically sets the output lines to a user-defined safe
state. The device remains in the watchdog state until the watchdog timer
is disarmed by the application and new I/O values are written, the NI 651x
is reset, or the computer is restarted.
Trigger Your Application with Change Detection
With change detection, you can automatically trigger your software
application to perform a digital read operation upon a digital change
of state. A digital change of state is defined as the rising edge (0 to 1
transition) or falling edge (1 to 0 transition) on one or more digital lines.
With change detection, you can monitor digital events with minimal
processor usage. No polling is necessary because the digital I/O device
generates an interrupt to automatically wake up your application.
Using NI-DAQmx software technology, an NI 651x notifies the
software application when the event is detected, causing the application
to automatically perform a read operation. To minimize the effects of
noisy input lines, you can use programmable input filters in combination
with change detection to eliminate spurious change detection events
caused by noise or glitches. NI-DAQmx also includes multithreaded
streaming technology so digital change detection events can occur
independently of other data acquisition activities such as analog input
or output events.
Eliminate Noise with Programmable Input Filters
Programmable input filters remove noise, glitches, and spikes on inputs
and provide debouncing for digital switches and relays. This feature is
important for applications in noisy industrial environments to prevent
false readings caused by noise. You can configure the programmable
input filter for each digital line by setting the filter time in seconds. Any
digital noise, glitch, or spike that is shorter than half of the specified
filter time is blocked by the digital I/O device, preventing invalid readings
and false triggers for change detection events.
Figure 4. Write Your Application with No Programming Using the NI DAQ Assistant
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
Low-Cost Industrial Digital I/O – 30 V, Bank Isolated
NI-DAQmx Software Technology
NI 651x devices require NI-DAQmx 7.1 or later (7.2 for NI 6511, NI 6512,
and NI 6513; 7.3 for NI 6510, NI 6516, NI 6517, NI 6518, and NI 6519).
NI-DAQmx measurement services software, included free with the purchase
of an NI 651x device, is available for download from ni.com/downloads.
With NI-DAQmx, you can program your NI digital I/O device in LabVIEW,
ANSI C, Microsoft Visual C++, and the Microsoft .NET languages C# and
Visual Basic .NET. You can access the full functionality and state-of-theart hardware technology of your NI 651x devices. NI-DAQmx technology
speeds up your development with many features such as automatic
code generation to make configuration and programming easy. NI 651x
devices take full advantage of key NI-DAQmx software technologies such
as multithreaded streaming technology for dramatic improvements in I/O
performance and ease of use.
• Use the DAQ Assistant to guide you to fast, accurate measurements
with no programming
• Use automatic code generation to create your application
in LabVIEW, ANSI C, Visual Basic .NET, or C#
• Take advantage of multithreaded streaming technology
for 1,000X performance improvements
• Use automatic timing, triggering, and synchronization technology
to make advanced applications easy
• Visit ni.com for more than 3,000 free software downloads
to jump-start your project
• Use the NI-DAQmx functions for jumper-free software configuration
of all digital I/O features without hardware switches/jumpers
• Develop your application with easy and open programming in
LabVIEW, ANSI C, Microsoft Visual C++, C#, and Visual Basic .NET
Digital I/O Connector
The 100-pin high-density SCSI connector on each NI 6511/12/13/14/15
device connects to 100-pin ribbon cables or shielded cables. For
low-cost unshielded connectivity, use the R1005050 ribbon cable with
two CB-50LP or CB-50 connector blocks (CB-100 kit). For shielded
connectivity, use the SH100-100-F shielded digital I/O cable with the
SCB-100 connector block.
The 37-pin D-Sub connector on NI 6510/16/17/18/19 devices connects
to 37-pin accessories including the SH37F-37M shielded digital I/O cable
with the CB-37FH DIN-rail-mountable connector block.
Ordering Information
PCI
NI PCI-6510............................................................................779081-01
NI PCI-6511............................................................................778966-01
NI PCI-6512............................................................................778968-01
NI PCI-6513............................................................................778970-01
NI PCI-6514............................................................................778836-01
NI PCI-6515............................................................................778835-01
NI PCI-6516............................................................................779082-01
NI PCI-6517............................................................................779083-01
NI PCI-6518............................................................................779084-01
NI PCI-6519............................................................................779085-01
PXI
NI PXI-6511............................................................................778967-01
NI PXI-6512............................................................................778969-01
NI PXI-6513............................................................................778971-01
NI PXI-6514............................................................................778965-01
NI PXI-6515............................................................................778964-01
Recommended Accessories
Device
NI 6510
NI 6511
NI 6512
NI 6513
NI 6514
NI 6515
NI 6516
NI 6517
NI 6518
NI 6519
Cable
SH37F-37M (778621-01)
SH100-100-F (185095-02)
SH100-100-F (185095-02)
SH100-100-F (185095-02)
SH100-100-F (185095-02)
SH100-100-F (185095-02)
SH37F-37M (778621-01)
SH37F-37M (778621-01)
SH37F-37M (778621-01)
SH37F-37M (778621-01)
Connector Block
CB-37FH (778673-01)
SCB-100 (776990-01)
SCB-100 (776990-01)
SCB-100 (776990-01)
SCB-100 (776990-01)
SCB-100 (776990-01)
CB-37FH (778673-01)
CB-37FH (778673-01)
CB-37FH (778673-01)
CB-37FH (778673-01)
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/daq.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
4
Low-Cost Industrial Digital I/O – 30 V, Bank Isolated
Physical
Specifications
These specifications are typical at 25 °C, unless otherwise noted.
Digital I/O
Number of channels............................ 32 or 64, optically isolated
Power-on state.................................... 0 (open), default;
user-programmable to 0 or 1
Data transfers ..................................... Interrupts, programmed I/O
I/O connector ...................................... 100-pin keyed female SCSI
connector or 37-pin male
D-Sub connector
Isolated Inputs
Number of input lines ......................... 0, 16, 32, or 64 bidirectional, each
bank with its own ground reference
isolated from other banks
Bank isolated inputs ........................... 8, 16, or 32 lines per bank
Maximum input voltage...................... 30 VDC
Level
Input logic low-voltage (VIL)
Input logic high-voltage (VIH)
Min
0 VDC
±11 VDC
Max
±4 VDC
±30 VDC
Input current
11 V inputs...................................... 4.5 mA/line, maximum
30 V inputs...................................... 12.5 mA/line, maximum
Propagation delay ............................... 75 µs, typical
Isolated Outputs
Number of lines .................................. 0, 16, 32, or 64, each bank with
its own ground reference isolated
from other banks
Bank isolated outputs ......................... 8, 16, or 32 lines per bank
Maximum switching voltage .............. 30 VDC
Maximum switching capacity
NI 6512, NI 6514, NI 6516, NI 6518 ... 350 mA (75 mA)
NI 6513, NI 6515, NI 6517, NI 6519 ... 500 mA (120 mA)
Pin 50/Pin 100 (at +5 V) ...................... 200 mA, maximum
(only on 100-pin devices)
Propagation delay ............................... 80 µs, typical with 100 Ω load
Dimensions
PCI................................................... 14.1 by 11.4 cm (5.54 by 4.47 in.)
PXI................................................... 10.0 by 16 cm (3.9 by 6.3 in.)
Environment
Operating temperature ....................... 0 to 55 °C
The following table lists the derated current values (100% duty cycle).
Ambient
Temperature
Up to 25 °C
Up to 35 °C
Up to 45 °C
Up to 55 °C
NI 6512, 6514
6516, 6518
All Lines
75 mA
65 mA
55 mA
50 mA
NI 6512, 6514,
6516, 6518
One Line per Port
350 mA
350 mA
350 mA
300 mA
NI 6513, 6515,
6517, 6519
All Lines
125 mA
125 mA
115 mA
100 mA
NI 6513, 6515,
6517, 6519
One Line per Port
475 mA
425 mA
375 mA
325 mA
Storage temperature........................... -20 to 70 °C
Relative humidity ................................ 10 to 90% noncondensing
Maximum altitude............................... 2,000 m
Note: The NI 651x devices are intended for indoor use only.
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Note: For UL and other safety certifications, refer to the product label or
visit ni.com/certification, search by model number or product line, and
click the appropriate link in the Certification column.
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards
for electrical equipment for measurement, control, and laboratory use:
• EN 61326 (IEC 61326): Class A emissions; Basic immunity
• EN 55011 (CISPR 11): Group 1, Class A emissions
• AS/NZS CISPR 11: Group 1, Class A emissions
• FCC 47 CFR Part 15B: Class A
Power Requirements
CE Compliance
+5 VDC (±5%)...................................... 150 mA
+3.3 VDC (±5%)................................... 300 mA, typical;
500 mA, maximum
Power available at I/O connector
Voltage............................................ +4.3 to +6.3 VDC
Current ............................................ 20 mA/port, typical
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
Note: The power at the I/O connector is derived from the output Vcc
(user-provided). The output Vcc must be greater than 10 VDC to ensure
that the output voltage is in the range of +4.3 to +6.3 VDC.
• 2006/95/EC; Low-Voltage Directive (safety)
• 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Note: Refer to the Declaration of Conformity (DoC) for this product for
any additional regulatory compliance information. To obtain the DoC for
this product, visit ni.com/certification, search by model number or
product line, and click the appropriate link in the Certification column.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
5
IN
TA
PL
AN
MA
IN
NI Services and Support
P
DE
LO
Y
EL
OP
SERVICE
NEEDS
V
DE
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our NI Professional Services team is composed of NI applications and
systems engineers and a worldwide National Instruments Alliance Partner
program of more than 600 independent consultants and integrators. Services
range from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to
engineers who speak your language. NI delivers industry-leading technical
support through online knowledge bases, our applications engineers,
and access to 14,000 measurement and automation professionals within
NI Developer Exchange forums. Find immediate answers to your questions
at ni.com/support.
We also offer service programs that provide automatic upgrades to your
application development environment and higher levels of technical support.
Visit ni.com/ssp.
Hardware Services
System Assurance Programs
NI system assurance programs are designed to make it even easier for you to
own an NI system. These programs include configuration and deployment
services for your NI PXI, CompactRIO, or Compact FieldPoint system. The
NI Basic System Assurance Program provides a simple integration test and
ensures that your system is delivered completely assembled in one box.
When you configure your system with the NI Standard System Assurance
Program, you can select from available NI system driver sets and application
development environments to create customized, reorderable software
configurations. Your system arrives fully assembled and tested in one box with
your software preinstalled. When you order your system with the standard
program, you also receive system-specific documentation including a bill of
materials, an integration test report, a recommended maintenance plan, and
frequently asked question documents. Finally, the standard program reduces
the total cost of owning an NI system by providing three years of warranty
coverage and calibration service. Use the online product advisors at
ni.com/advisor to find a system assurance program to meet your needs.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services
to recalibrate your products, and automated calibration software specifically
designed for use by metrology laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • 800 813 3693
National Instruments • [email protected]
©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, Measurement Studio, MITE, National Instruments, National Instruments Alliance Partner, NI, and
ni.com are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the
United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a
business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 2009-10837-301-101-D
Similar pages