NPF-120D 120W Single Output Switching Power Supply F 110 M M ■ Features Universal AC input / Full range (up to 305VAC) Built-in active PFC function High efficiency up to 90% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Fully isolated plastic case Fully encapsulated with IP67 level Class Ⅱ power unit, no FG Built-in 3 in 1 dimming function SELV IP67 series 05 ■ Applications Indoor LED lighting LED decorative lighting LED architecture lighting Moving sign Tunnel lighting (0~10Vdc or PWM signal or resistance) Suitable for dry / damp / wet locations No load power consumption<0.5W 5 years warranty ■ Description NPF-120D is one 120W waterproof single-output LED power supply series. In addition to the fundamental LED driving function, NPF-120D is equipped with a built-in 3 in 1 dimming function (0~10Vdc, PWM signal or resistance) that simplifies the brightness adjustment for system designers so as to achieve light reduction and energy conservation. The entire series adopts the universal input range from 90VAC to 305VAC and incorporates the built-in PFC function. The enclosure design is a 94V-0 flame retardant plastic case. The interior is fully potted with silicone that enhances the heat dissipation and allows the power supply to meet the anti-vibration demand up to 5G; it also thus conforms to IP67 level, enabling NPF-120D to be used in a highly dusty and highly humid harsh environment. Providing a high efficiency up to 90% and a low no load power consumption below 0.5W, NPF-120D can satisfy the energy saving demand for the new generation LED lighting. The class Ⅱ design (no FG) and the double insulation weather-resistant cable (SJTW) on the input side make it convenient for users to flexibly install on various types of lighting systems. The entire series can operate under the temperature between -40~+70℃ and comply with the relevant global lighting safety certification. ■ Model Encoding NPF - 120 D - 12 Output voltage Built-in 3 in 1 dimming function Output wattage Series name File Name:NPF-120D-SPEC 2015-11-30 NPF-120D 120W Single Output Switching Power Supply series SPECIFICATION MODEL NPF-120D-12 NPF-120D-15 NPF-120D-20 NPF-120D-24 NPF-120D-30 NPF-120D-36 NPF-120D-42 NPF-120D-48 NPF-120D-54 DC VOLTAGE OUTPUT 30V 36V 42V 15V 20V 24V CONSTANT CURRENT REGION 7.2 ~ 12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V RATED CURRENT 10A 8A 6A 5A 4A 3.4A 2.9A 2.5A 2.3A RATED POWER 120W 120W 120W 120W 120W 122.4W 121.8W 120W 124.2W 12V 48V 54V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p VOLTAGE TOLERANCE Note.3 ±4.0% ±4.0% ±4.0% ±4.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±2.0% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME Note.4 500ms, 80ms at 95% load 230VAC / 115VAC HOLD UP TIME (Typ.) 16ms/230VAC VOLTAGE RANGE 90 ~ 305VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.97/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) 16ms/115VAC at full load 127 ~ 431VDC TOTAL HARMONIC DISTORTION THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input INPUT EFFICIENCY (Typ.) 87.5% AC CURRENT (Typ.) 1.3A / 115VAC INRUSH CURRENT(Typ.) COLD START60A(twidth=520μs measured at 50% Ipeak) at 230VAC 89% 88% 89.5% 0.65A / 230VAC 89% 89.5% 89.5% 90% 90% 0.55A / 277VAC MAX. NO. of PSUs on 16A 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT OVER CURRENT PROTECTION SHORT CIRCUIT <0.25mA / 277VAC 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 15 ~ 17V OVER VOLTAGE OVER TEMPERATURE 17.5 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 46 ~ 54V 54 ~ 60V 59 ~ 66V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover WORKING TEMP. -40 ~ +70℃ (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH SAFETY & EMC TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS UL8750, CSA C22.2 No. 250. 13-12 , ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved; Design refer to EN60335-1 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH EMC EMISSION Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge 2KV), criteria A MTBF 233.9K hrs min. OTHERS DIMENSION PACKING NOTE MIL-HDBK-217F (25℃) 191*63*37.5mm (L*W*H) 0.97Kg; 15pcs/15.6Kg/0.87CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:NPF-120D-SPEC 2015-11-30 NPF-120D 120W Single Output Switching Power Supply series Block Diagram PFC fosc : 50~120KHz PWM fosc : 60~130KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V DIM+ DIM- O.L.P. O.T.P. O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 230VAC Input only 70 12,15V only 50 LOAD (%) LOAD (%) 60 40 20 -40 -25 0 15 30 40 45 50 60 70 (HORIZONTAL) 60 50 40 90 100 AMBIENT TEMPERATURE (℃) 125 135 145 155 165 175 180 200 230 305 INPUT VOLTAGE (V) 60Hz Power Factor Characteristic PF Constant Current Mode 1 .0 0 0 .9 5 0 .9 0 0 .8 5 0 .8 0 0 .7 5 0 .7 0 0 .6 5 0 .6 0 0 .5 5 0 .5 0 0 .4 5 0 .4 0 0 .3 5 0 .3 0 277V 230V 115V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% (120W) LOAD File Name:NPF-120D-SPEC 2015-11-30 120W Single Output Switching Power Supply NPF-120D series EFFICIENCY vs LOAD (48V Model) EFFICIENCY (%) NPF-120D series possess superior working efficiency that up to 90% can be reached in field applications. 92 91 90 89 88 87 86 85 84 83 82 81 80 10% 277V 230V 115V 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. 100 Vo(%) Constant Current area Should there be any compatibility issues, please contact MEAN WELL. 60 (min.) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:NPF-120D-SPEC 2015-11-30 NPF-120D 120W Single Output Switching Power Supply series DIMMING OPERATION AC/L(Brown) AC/N(Blue) DIM+(Blue) DIM-(White) +V(Red) -V(Black) NPF-120D ※ Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or 0 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-. ※ Please DO NOT connect "DIM-" to "-V". ※ Reference resistance value for output current adjustment (Typical) Short 10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ Single driver Resistance Multiple drivers value (N=driver quantity for synchronized Short 10KΩ/N 20KΩ/N 30KΩ/N 40KΩ/N 50KΩ/N 60KΩ/N 70KΩ/N 80KΩ/N 90KΩ/N 100KΩ/N dimming operation) Percentage of rated current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN ----95%~108% ※ 0 ~ 10V dimming function for output current adjustment (Typical) Dimming value 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN Percentage of rated current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% ※ 10V PWM signal for output current adjustment (Typical): Frequency range:100Hz ~ 3KHz Duty value 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN Percentage of rated current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% ◎ Dimming Characteristic 95%~108% when DIM+/DIM- are open circuit. 100% Output Current Percentage of rated current(%) 90% 80% 70% 60% 50% 40% 30% 20% 10% Note 0% 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N Dimming input 0~10V Duty cycle of 10V PWM (frequency range = 100~3KHz) Short~100KΩ/N resistance (N=driver quantity for synchronized dimming operation ) ※ Note : 1. Min. dimming level is about 6% 2. The output current is not defined when 0%< I out<6% 3. The output current could drop down to 0% when dimming input is about 0 KΩor 0Vdc, or 10V PWM signal with 0% duty cycle File Name:NPF-120D-SPEC 2015-11-30 NPF-120D 120W Single Output Switching Power Supply Mechanical Specification Case No. PWM-120 series Unit:mm 191 5 5 300±20 50±3 300±20 UL2464 18AWG×2C DIM+(Blue) DIM-(White) 95.5 63 AC/L(Brown) AC/N(Blue) 31.5 SJTW 18AWG×2C +V(Red) -V(Black) 5 SJTW 14AWG×2C 2 -ψ 4.5 50±3 ※ T case: Max. Case Temperature. 37.5 5 Recommend Mounting Direction Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:NPF-120D-SPEC 2015-11-30