HYBRID IC M57140-01 IPM POWER SUPPLY HYBRID IC H TERMINAL NUMBER 1 14 2 13 3 F 12 11 J 10 9 E 4 5 8 6 7 G B D C A 14 4, 5, 6 OUT PUT 15V, 30mA 13 Features:: • Output Specification: +15V x 4, Total 3W max. 12 INPUT DC 20V OUT PUT 15V, 30mA 11 PUSH-PULL CONVERTER CONTROL CIRCUIT 10 OUT PUT 15V, 30mA 9 1, 2, 3 8 7 Inches Millimeters Dimensions • Primary-to-secondary Isolation: 2500 VRMS, One Minute • Secondary-to-secondary Isolation Voltage: 1500 VRMS, One Minute • Compact, Low Profile Design OUT PUT 15V, 100mA Outline Drawing and Circuit Diagram Dimensions Description: M57140-01 is an isolated DC-to-DC converter designed to drive IPMs (Intelligent Power Modules). With an input of DC 20V, the module supplies four 15V outputs. Isolation is provided from primary to secondary and also between the secondaries. Interwinding isolation is designed for driving the IPM. Inches Millimeters A 2.03 51.5 F 0.02 0.55 B 0.71 18.0 MAX G 0.08 2.1 C .39±.06 12.5±1.5 H 0.08 2.1 D .18±.06 4.5±1.5 J 1.13 28.8 E 0.07 1.8 Applications: • IPMs for General Purpose Inverter and AC Servo • Power Source for MOSFET Driving Circuits Ordering Information: M57140-01 HYBRID IC M57140-01 IPM POWER SUPPLY HYBRID IC Absolute Maximum Ratings, VIN = 20V, Ta = 25 °C unless otherwise specified Item Symbol Test Conditions Limit Input Voltage VIN Terminals 4 , 5 , 6 - 1 , 2 , 3 Load Current IL Terminals 14 - 13 , 12 - 11 , 10 - 9 Terminals 8 - 7 Units 25 Volts 30 mA 100 mA Operating Temperature Topr There Should be -10 ~ +75 °C Storage Temperature Tstg No Condensation -20 ~ +85 °C Internal Power Dissipation Pd Ð 1.5 Watts Primary-to-Secondary Isolation 1 Minute 2500 Vrms Secondary-to-Secondary Isolation 1 Minute 1500 Vrms Electrical Characteristics, VIN = 20V, Ta = 25 °C unless otherwise specified Characteristics Symbol Test Conditions Min. Input Source Voltage VIN Direct Current Output Voltage VO Between Pins 10 - 9 , 12 - 11, 14 - 13, Typ. Max. Units 18 20 22 Volts 13.5 15.0 16.5 Volts 15.0 16.5 Volts Ð mA mA IL = 30mA Peak Load Current Between Pins 8 - 7 , IL = 100mA 13.5 ILP Between Pins 10 - 9 , 12 - 11, 14 - 13 Ð 33 Reg-out Between Pins 10 - 9 , 12 - 11, 14 - 13, Between Pins 8 - 7 Load Regulation Ð 110 Ð Ð 5 10 Ð 7 12 % IL = 0 ~ 30mA Between Pins 8 - 7 , IL = 0 ~ 100mA Efficiency h Between Pins 10 - 9 , 12 - 11, 14 - 13, Ð 70 Ð Ð 70 Ð % Between Pins 10 - 9 , % IL = 30mA Between Pins 8 - 7 , IL = 100mA Application Circuit 8 + 33m F IL VC 7 4, 5, 6 10 + 10m F IL VC 9 + M57140-01 VIN = 20V 330m F 12 + 1, 2, 3 10m F IL VC 11 14 + 10m F 13 IL VC % HYBRID IC M57140-01 IPM POWER SUPPLY HYBRID IC Application Circuit P R + C AMP SG U 14 13 +15 11 , 12 INPUT DC113V-380V 2.2m F + 5 +15 4, 5, 6 + 50V 330m F M57120L-01 12 0 0 R V 10 +15 M57140-01 + C 9 2 AMP SG 0 1, 2, 3 6 AMP SG 11 R 1 + C + 50V 47m F W 8 +15 0 AMP 7 SG R + C AMP SG R – TO STABILIZE WHEN NOT LOADED C – TO SMOOTH OUTPUT VOLTAGE AMP SG IPM N Handling Precautions: • When M57140-01 is used under excessive load condition, output side rectifying diodes will be destroyed. Care should be exercised so as not to operate the device above the rated maximum load current. • Coating Materials should not be applied on this device because the application of coating materials for waterproofing could cause a stress and destroy a device. HYBRID IC M57140-01 IPM POWER SUPPLY HYBRID IC OUTPUT VOLTAGE LOAD CURRENT CHARACTERISTICS BETWEEN TERMINALS 8 AND 7 OUTPUT VOLTAGE -LOAD CURRENT CHARACTERISTICS BETWEEN TERMINALS 10 - 9 , 12 - 11 , 14 - 13 17 INPUT CURRENT - OUTPUT POWER 0.3 17 Ta = 60°C 25°C 15 0°C VIN = 20V CONDITION: OTHER OUTPUT TERMINALS ARE NOT LOADED 14 0 16 INPUT CURRENT, IIN, (mA) 16 OUTPUT VOLTAGE, Vo, (VOLTS) OUTPUT VOLTAGE, Vo, (VOLTS) VIN = 20V Ta = 60°C 15 0°C, 25°C VIN = 20V CONDITION: TERMINALS 8 AND 7 ARE NOT LOADED 14 20 40 60 80 100 25°C 0.1 60°C 0 0 0 Ta = 0°C 0.2 0 10 LOAD CURRENT, IL, (mA) 20 0 30 OUTPUT VOLTAGE VS AMBIENT TEMPERATURE BETWEEN TERMINALS 8 AND 7 OUTPUT VOLTAGE VS AMBIENT TEMPERATURE BETWEEN TERMINALS 10 - 9 , 12 - 11 , 14 - 13 20 20 16 16 8 VIN = 20V CONDITION: OTHER OUTPUT TERMINALS ARE NOT LOADED 4 0 -20 0 20 40 60 Ta = 25°C VIN = 20V 60 12 8 VIN = 20V CONDITION: TERMINALS 8 AND 7 ARE NOT LOADED 4 AMBIENT TEMPERATURE, Ta, (°C) 20 40 60 80 IL = 0mA 16 14 IL = 100mA 12 10 18 IL = 0mA 16 30mA 14 12 10 0 0 0 18 19 20 21 INPUT VOLTAGE, VIN, (VOLTS) 22 23 0 18 19 20 21 INPUT VOLTAGE, VIN, (VOLTS) 22 0 1 2 3 TOTAL OUTPUT POWER, Po, (WATTS) Ta = 25°C 18 OUTPUT VOLTAGE, Vo, (VOLTS) OUTPUT VOLTAGE, Vo, (VOLTS) 0 0 20 Ta = 25°C 40 20 OUTPUT VOLTAGE VS INPUT VOLTAGE BETWEEN TERMINALS 10 - 9 , 12 - 11 , 14 - 13 OUTPUT VOLTAGE VS INPUT VOLTAGE BETWEEN TERMINALS 8 AND 7 50 30 AMBIENT TEMPERATURE, Ta, (°C) 20 4 IL = 30mA 0 -20 80 3 EFFICIENCY CHARACTERISTICS EFFICIENCY, h , (%) OUTPUT VOLTAGE, Vo, (VOLTS) OUTPUT VOLTAGE, Vo, (VOLTS) 12 2 80 70 IL = 100mA 1 OUTPUT POWER, Po, (WATTS) LOAD CURRENT, IL, (mA) 23 4 IHYBRID IC M57140-01 IPM POWER SUPPLY HYBRID IC FOR SAFETY USING Great detail and careful attention are given to the production activity of Hics, such as the development, the quality of production, and in it’s reliability. However the reliability of Hics depends not only on their own factors but also in their condition of usage. When handling Hics, please note the following cautions. CAUTIONS Packing Carrying The materials used in packing Hics can only withstand normal external conditions. When exposed to outside shocks, rain and certain environmental contaminators, the packing materials will deteriorates. Please take care in handling. 1) 2) 3) 4) 5) Don’t stack boxes too high. Avoid placing heavy materials on boxes. Boxes must be positioned correctly during transportation to avoid breakage. Don't throw or drop boxes. Keep boxes dry. Avoid rain or snow. Minimal vibration and shock during transportation is desirable. Storage When storing Hics, please observe the following notices or possible deterioration of their electrical characteristics, risk of solder ability, and external damage may occur. 1) Devices must be stored where fluctuation of temperature and humidity is minimal, and must not be exposed to direct sunlight. Store at the normal temperature of 5 to 30 degrees Celsius with humidity at 40 to 60%. 2) Avoid locations where corrosive gasses are generated or w here much dust accumulates. 3) Storage cases must be static proof. 4) Avoid putting weight on boxes. Extended storage When extended storage is necessary, Hics must be kept non-processed. When using Hics which have been stored for more than one year or under severe conditions, be sure to check that the exterior is free from flaw and other damages. Maximum ratings To prevent any electrical damages, use Hics within the maximum ratings. The temperature, current, voltage, etc. must not exceed these conditions. Polarity To protect Hics from destruction and deterioration due to wrong insertion, make sure of polarity in inserting leads into the board holes, conforming to the external view for the terminal arrangement. IHYBRID IC M57140-01 IPM POWER SUPPLY HYBRID IC Marketing division, Marketing planning department 6-41 Tsukuba, Isahaya, Nagasaki, 854-0065 Japan Keep safety first in your circuit designs! ·ISAHAYA Electronics Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (1) placement of substitutive, auxiliary, (2) use of non-farmable material or (3) prevention against any malfunction or mishap. Notes regarding these materials ·These materials are intended as a reference to our customers in the selection of the ISAHAYA products best suited to the customer’s application; they don't convey any license under any intellectual property rights, or any other rights, belonging ISAHAYA or third party. ·ISAHAYA Electronics Corporation assumes no responsibility for any damage, or infringement of any third party's rights , originating in the use of any product data, diagrams, charts or circuit application examples contained in these materials. ·All information contained in these materials, including product data, diagrams and charts, represent information on products at the time of publication of these materials, and are subject to change by ISAHAYA Electronics Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact ISAHAYA Electronics Corporation or an authorized ISAHAYA products distributor for the latest product information before purchasing product listed herein. ·ISAHAYA Electronics Corporation products are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact ISAHAYA electronics corporation or an authorized ISAHAYA products distributor when considering the use of a product contained herein for any specific purposes , such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use. ·The prior written approval of ISAHAYA Electronics Corporation is necessary to reprint or reproduce in whole or in part these materials. ·If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or re-export contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited. ·Please contact ISAHAYA Electronics Corporation or authorized ISAHAYA products distributor for further details on these materials or the products contained therein. Nov.2002