TI1 HPA00322ZWLR 25-bit configurable registered buffer with address-parity test Datasheet

SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
25-BIT CONFIGURABLE REGISTERED BUFFER WITH ADDRESS-PARITY TEST
FEATURES
1
• Member of the Texas Instruments Widebus+™
Family
• Pinout Optimizes DDR2 DIMM PCB Layout
• Configurable as 25-Bit 1:1 or 14-Bit 1:2
Registered Buffer
• Chip-Select Inputs Gate the Data Outputs from
Changing State and Minimizes System Power
Consumption
• Output Edge-Control Circuitry Minimizes
Switching Noise in an Unterminated Line
2
•
•
•
•
•
•
Supports SSTL_18 Data Inputs
Differential Clock (CLK and CLK) Inputs
Supports LVCMOS Switching Levels on the
Control and RESET Inputs
Checks Parity on DIMM-Independent Data
Inputs
Able to Cascade with a Second
SN74SSTUB32866
Supports Industrial Temperature Range
(-40°C to 85°C)
DESCRIPTION
This 25-bit 1:1 or 14-bit 1:2 configurable registered buffer is designed for 1.7-V to 1.9-V VCC operation. In the
1:1 pinout configuration, only one device per DIMM is required to drive nine SDRAM loads. In the 1:2 pinout
configuration, two devices per DIMM are required to drive 18 SDRAM loads.
All inputs are SSTL_18, except the reset (RESET) and control (Cn) inputs, which are LVCMOS. All outputs are
edge-controlled circuits optimized for unterminated DIMM loads and meet SSTL_18 specifications, except the
open-drain error (QERR) output.
The SN74SSTUB32866 operates from a differential clock (CLK and CLK). Data are registered at the crossing of
CLK going high and CLK going low.
The SN74SSTUB32866 accepts a parity bit from the memory controller on the parity bit (PAR_IN) input,
compares it with the data received on the DIMM-independent D-inputs (D2–D3, D5–D6, D8–D25 when C0 = 0
and C1 = 0; D2–D3, D5–D6, D8–D14 when C0 = 0 and C1 = 1; or D1-D6, D8-D13 when C0 = 1 and C1 = 1) and
indicates whether a parity error has occurred on the open-drain QERR pin (active low). The convention is even
parity; i.e., valid parity is defined as an even number of ones across the DIMM-independent data inputs,
combined with the parity input bit. To calculate parity, all DIMM-independent data inputs must be tied to a known
logic state.
When used as a single device, the C0 and C1 inputs are tied low. In this configuration, parity is checked on the
PAR_IN input signal, which arrives one cycle after the input data to which it applies. Two clock cycles after the
data are registered, the corresponding partial-parity-out (PPO) and QERR signals are generated.
When used in pairs, the C0 input of the first register is tied low, and the C0 input of the second register is tied
high. The C1 input of both registers are tied high. Parity, which arrives one cycle after the data input to which it
applies, is checked on the PAR_IN input signal of the first device. Two clock cycles after the data are registered,
the corresponding PPO and QERR signals are generated on the second device. The PPO output of the first
register is cascaded to the PAR_IN of the second SN74SSTUB32866. The QERR output of the first
SN74SSTUB32866 is left floating, and the valid error information is latched on the QERR output of the second
SN74SSTUB32866.
ORDERING INFORMATION
TA
-40°C to 85°C
(1)
PACKAGE
(1)
ORDERABLE PART NUMBER
TOP-SIDE MARKING
LFBGA–ZKE
Tape and reel
SN74SSTUB32866ZKER
SB866
LFBGA–ZWL
Tape and reel
SN74SSTUB32866ZWLR
SB866
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
1
2
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Widebus+ is a trademark of Texas Instruments.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2006–2007, Texas Instruments Incorporated
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
DESCRIPTION (CONTINUED)
If an error occurs and the QERR output is driven low, it stays latched low for a minimum of two clock cycles or
until RESET is driven low. If two or more consecutive parity errors occur, the QERR output is driven low and
latched low for a clock duration equal to the parity-error duration or until RESET is driven low. The
DIMM-dependent signals (DCKE, DCS, DODT, and CSR) are not included in the parity-check computation.
The C0 input controls the pinout configuration of the 1:2 pinout from register-A configuration (when low) to
register-B configuration (when high). The C1 input controls the pinout configuration from 25-bit 1:1 (when low) to
14-bit 1:2 (when high). C0 and C1 should not be switched during normal operation. They should be hard-wired to
a valid low or high level to configure the register in the desired mode. In the 25-bit 1:1 pinout configuration, the
A6, D6, and H6 terminals are driven low and are do-not-use (DNU) pins.
In the DDR2 RDIMM application, RESET is specified to be completely asynchronous with respect to CLK and
CLK. Therefore, no timing relationship can be ensured between the two. When entering reset, the register is
cleared, and the data outputs are driven low quickly, relative to the time required to disable the differential input
receivers. However, when coming out of reset, the register becomes active quickly, relative to the time required
to enable the differential input receivers. As long as the data inputs are low, and the clock is stable during the
time from the low-to-high transition of RESET until the input receivers are fully enabled, the design of the
SN74SSTUB32866 ensures that the outputs remain low, thus ensuring there will be no glitches on the output.
To ensure defined outputs from the register before a stable clock has been supplied, RESET must be held in the
low state during power up.
The device supports low-power standby operation. When RESET is low, the differential input receivers are
disabled, and undriven (floating) data, clock, and reference voltage (VREF) inputs are allowed. In addition, when
RESET is low, all registers are reset and all outputs are forced low, except QERR. The LVCMOS RESET and Cn
inputs always must be held at a valid logic high or low level.
The device also supports low-power active operation by monitoring both system chip select (DCS and CSR)
inputs and gates the Qn and PPO outputs from changing states when both DCS and CSR inputs are high. If
either DCS or CSR input is low, the Qn and PPO outputs function normally. Also, if the internal low-power signal
(LPS1) is high (one cycle after DCS and CSR go high), the device gates the QERR output from changing states.
If LPS1 is low, the QERR output functions normally. The RESET input has priority over the DCS and CSR control
and, when driven low, forces the Qn and PPO outputs low and forces the QERR output high. If the DCS control
functionality is not desired, the CSR input can be hard-wired to ground, in which case the setup-time requirement
for DCS is the same as for the other D data inputs. To control the low-power mode with DCS only, the CSR input
should be pulled up to VCC through a pullup resistor.
The two VREF pins (A3 and T3) are connected together internally by approximately 150Ω. However, it is
necessary to connect only one of the two VREF pins to the external VREF power supply. An unused VREF pin
should be terminated with a VREF coupling capacitor.
2
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
PACKAGE
Terminal Assignments for 1:1 Register-A (C0 = 0, C1 = 0)
1
2
3
4
5
6
A D1 (DCKE)
PPO
VREF
VCC
Q1 (QCKE)
DNU
B
D2
D15
GND
GND
Q2
Q15
C
D3
D16
VCC
VCC
Q3
Q16
QERR
GND
GND
Q4 (QODT)
DNU
D D4 (DODT)
E
D5
D17
VCC
VCC
Q5
Q17
F
D6
D18
GND
GND
Q6
Q18
G
PAR_IN
RESET
VCC
VCC
C1
C0
H
CLK
D7 (DCS)
GND
GND
Q7 (QCS)
DNU
J
CLK
CSR
VCC
VCC
NC
NC
K
D8
D19
GND
GND
Q8
Q19
L
D9
D20
VCC
VCC
Q9
Q20
M
D10
D21
GND
GND
Q10
Q21
N
D11
D22
VCC
VCC
Q11
Q22
P
D12
D23
GND
GND
Q12
Q23
R
D13
D24
VCC
VCC
Q13
Q24
T
D14
D25
VREF
VCC
Q14
Q25
Each pin name in parentheses indicates the DDR2 DIMM signal name.
DNU - Do not use
NC - No internal connection
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
3
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Logic Diagram for 1:1 Register Configuration (Positive Logic); C0 = 0, C1 = 0
4
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Parity Logic Diagram for 1:1 Register Configuration (Positive Logic); C0 = 0, C1 = 0
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
5
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
PACKAGE
(TOP VIEW)
1
2
3
4
5
6
A D1 (DCKE)
PPO
VREF
VCC
Q1A (QCKEA)
Q1B (QCKEB)
B
D2
DNU
GND
GND
Q2A
Q2B
C
D3
DNU
VCC
VCC
Q3A
Q3B
QERR
GND
GND
Q4A (QODTA)
Q4B(QODTB)
D D4 (DODT)
E
D5
DNU
VCC
VCC
Q5A
Q5B
F
D6
DNU
GND
GND
Q6A
Q6B
G
PAR_IN
RESET
VCC
VCC
C1
C0
H
CLK
D7 (DCS)
GND
GND
Q7A (QCSA)
Q7B (QCSB)
J
CLK
CSR
VCC
VCC
NC
NC
K
D8
DNU
GND
GND
Q8A
Q8B
L
D9
DNU
VCC
VCC
Q9A
Q9B
M
D10
DNU
GND
GND
Q10A
Q10B
N
D11
DNU
VCC
VCC
Q11A
Q11B
P
D12
DNU
GND
GND
Q12A
Q12B
R
D13
DNU
VCC
VCC
Q13A
Q13B
T
D14
DNU
VREF
VCC
Q14A
Q14B
Each pin name in parentheses indicates the DDR2 DIMM signal name.
DNU - Do not use
NC - No internal connection
6
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Logic Diagram for 1:2 Register-A Configuration (Positive Logic); C0 = 0, C1 = 1
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
7
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Parity Logic Diagram for 1:2 Register-A Configuration (Positive Logic); C0 = 0, C1 = 1
8
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
PACKAGE
(TOP VIEW)
Terminal Assignments for 1:2 Register-B (C0 = 1, C1 = 1)
1
2
3
4
5
6
A
D1
PPO
VREF
VCC
Q1A
Q1B
B
D2
DNU
GND
GND
Q2A
Q2B
C
D3
DNU
VCC
VCC
Q3A
Q3B
D
D4
QERR
GND
GND
Q4A
Q4B
E
D5
DNU
VCC
VCC
Q5A
Q5B
F
D6
DNU
GND
GND
Q6A
Q6B
G
PAR_IN
RESET
VCC
VCC
C1
C0
H
CLK
D7 (DCS)
GND
GND
Q7A (QCSA)
Q7B (QCSB)
J
CLK
CSR
VCC
VCC
NC
NC
K
D8
DNU
GND
GND
Q8A
Q8B
L
D9
DNU
VCC
VCC
Q9A
Q9B
M
D10
DNU
GND
GND
Q10A
Q10B
N D11 (DODT)
DNU
VCC
VCC
P
D12
DNU
GND
GND
Q12A
Q12B
R
D13
DNU
VCC
VCC
Q13A
Q13B
DNU
VREF
VCC
T D14 (DCKE)
Q11A (QODTA) Q11B (QODTB)
Q14A (QCKEA) Q14B (QCKEB)
Each pin name in parentheses indicates the DDR2 DIMM signal name.
DNU - Do not use
NC - No internal connection
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
9
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Logic Diagram for 1:2 Register-B Configuration C0 = 1, C1 = 1
10
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Parity Logic Diagram for 1:2 Register-B Configuration (Positive Logic); C0 = 1, C1 = 1
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
11
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
TERMINAL FUNCTIONS
TERMINAL
NAME
ELECTRICAL
CHARACTERISTICS
DESCRIPTION
GND
Ground
Ground input
VCC
Power-supply voltage
1.8 V nominal
VREF
Input reference voltage
0.9 V nominal
CLK
Positive master clock input
Differential input
CLK
Negative master clock input
Differential input
C0, C1
Configuration control input. Register A or Register B and 1:1 mode or 1:2 mode select.
LVCMOS inputs
RESET
Asynchronous reset input. Resets registers and disables VREF, data, and clock differential-input
receivers. When RESET is low, all Q outputs are forced low and the QERR output is forced high.
LVCMOS input
D1-D25
Data input. Clocked in on the crossing of the rising edge of CLK and the falling edge of CLK.
SSTL_18 inputs
CSR, DCS
Chip select inputs. Disables D1–D25 (1) outputs switching when both inputs are high
SSTL_18 inputs
DODT
The outputs of this register bit will not be suspended by the DCS and CSR control.
SSTL_18 input
DCKE
The outputs of this register bit will not be suspended by the DCS and CSR control.
SSTL_18 input
PAR_IN
Parity input. Arrives one clock cycle after the corresponding data input. Pulldown resistor of typical
150kΩ to GND.
SSTL_18 input
pulldown
Q1–Q25 (2)
Data outputs that are suspended by the DCS and CSR control.
1.8 V CMOS outputs
PPO
Partial parity out. Indicates odd parity of inputs D1–D25. (1)
1.8 V CMOS output
QCS
Data output that will not be suspended by the DCS and CSR control
1.8 V CMOS output
QODT
Data output that will not be suspended by the DCS and CSR control
1.8 V CMOS output
QCKE
Data output that will not be suspended by the DCS and CSR control
1.8 V CMOS output
QERR
Output error bit. Timing is determined by the device mode.
Open-drain output
NC
No internal connection
DNU
Do not use. Inputs are in standby-equivalent mode, and outputs are driven low.
(1)
(2)
Data inputs = D2, D3, D5, D6, D8-D25 when C0 = 0 and C1 = 0
Data inputs = D2, D3, D5, D6, D8-D14 when C0 = 0 and C1 = 1
Data inputs = D1-D6, D8-D10, D12, D13 when C0 = 1 and C1 = 1.D
Data outputs = Q2, Q3, Q5, Q6, Q8-Q25 when C0 = 0 and C1 = 0
Data outputs = Q2, Q3, Q5, Q6, Q8-Q14 when C0 = 0 and C1 = 1
Data outputs = Q1-Q6, Q8-Q10, Q12, Q13 when C0 = 1 and C1 = 1.
FUNCTION TABLE
INPUTS
OUTPUTS
RESET
DCS
CSR
CLK
CLK
H
L
X
↑
↓
L
L
H
L
X
↑
↓
H
H
H
X
L
↑
↓
L
L
H
X
L
↑
↓
H
H
H
H
H
↑
↓
X
Q0
H
X
X
L or H
L or H
X
Q0
X or Floating
X or Floating
X or Floating
L
L
X or Floating X or Floating
Dn
Qn
FUNCTION TABLE
INPUTS
12
OUTPUTS
RESET
CLK
CLK
H
↑
↓
H
H
↑
↓
L
L
H
L orH
L orH
X
Q0
L
X or Floating
X or Floating
X or Floating
L
Submit Documentation Feedback
DCKE, DCS, DODT QCKE, QCS, QODT
H
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
PARITY AND STANDBY FUNCTION
INPUTS
OUTPUTS
RESET
CLK
CLK
DCS
CSR
Σ OF INPUTS = H
D1–D25 (1)
PAR_IN (2)
H
↑
↓
L
X
Even
L
L
H
H
↑
↓
L
X
Odd
L
H
L
H
↑
↓
L
X
Even
H
H
L
H
↑
↓
L
X
Odd
H
L
H
H
↑
↓
H
L
Even
L
L
H
H
↑
↓
H
L
Odd
L
H
L
H
↑
↓
H
L
Even
H
H
L
H
↑
↓
H
L
Odd
H
L
H
H
↑
↓
H
H
X
X
PPO0
QERR 0
H
L or H
L or H
X
X
X
X
PPO0
QERR 0
L
X or
Floating
X or
Floating
X or
Floating
X or
Floating
X
X or
Floating
L
H
(1)
(2)
(3)
PPO
QERR
(3)
Data inputs = D2-D3, D5-D6, D8-D25 when C0 = 0 and C1 = 0
Data inputs = D2-D3, D5-D6, D8-D14 when C0 = 0 and C1 = 1
Data inputs = D1-D6, D8-D10, D12, D13 when C0 = 1 and C1 = 1
PAR_IN arrives one clock cycle (C0 = 0) or two clock cycles (C0 = 1) after the data to which it applies.
This transition assumes that QERR is high at the crossing of CLK going high and CLK going low. If
QERR goes low, it stays latched low for a minimum of two clock cycles or until RESET is driven low. If
two or more consecutive parity errors occur, the QERR output is driven low and latched low for a clock
duration equal to the parity duration or until RESET is driven low.
PARITY ERROR DETECT IN LOW-POWER MODE (1)
INPUT-DATA
ERROR
OCCURRENCE (2)
(1)
(2)
(3)
1:1 MODE
(C0 = 0, C1 = 0)
1:2 REGISTER-A MODE
(C0 = 0, C1 = 1)
1:2 REGISTER-B MODE
(C0 = 1, C1 = 1)
CASCADED MODE
(Registers A and B)
PPO
DURATION (3)
QERR
DURATION(3)
PPO
DURATION(3)
QERR
DURATION(3)
PPO
DURATION(3)
QERR
DURATION(3)
PPO
DURATION(3)
QERR
DURATION(3)
n–4
1 Cycle
2 Cycles
1 Cycle
2 Cycles
1 Cycle
2 Cycles
1 Cycle
2 Cycles
n–3
1 Cycle
2 Cycles
1 Cycle
2 Cycles
1 Cycle
2 Cycles
1 Cycle
2 Cycles
n–2
1 Cycle
2 Cycles
1 Cycle
2 Cycles
1 Cycle
2 Cycles
1 Cycle
2 Cycles
n–1
LPM + 2
Cycles
LPM + 2
Cycles
LPM + 1
Cycle
LPM + 1
Cycle
LPM + 2
Cycles
LPM + 2
Cycles
LPM + 2
Cycles
LPM + 2
Cycles
n
Not detected
Not detected
Not detected
Not detected
Not detected
Not detected
Not detected
Not detected
If a parity error occurs before the device enters the low-power mode (LPM), the behavior of PPO and QERR is dependent on the mode
of the device and the position of the parity error occurrence. This table illustrates the low-power-mode effect on parity detect. The
low-power mode is activated on the n clock cycle when DCS and CSR go high.
The clock-edge position of a one cycle data-input error relative to the clock-edge (n) which initiates LPM at the DCS and CSR inputs.
If an error occurs, then QERR output may be driven low and the PPO output driven high. These columns show the clock duration for
which the PPO signal will be high.
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
13
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
VALUE
UNIT
–0.5 to 2.5
V
(3)
-0.5 to VCC + 0.5
V
(2) (3)
VCC
Supply voltage range
VI
Input voltage range (2)
VO
Output voltage range
–0.5 to VCC + 0.5
V
IIK
Input clamp current, (VI < 0 or VI > VCC)
±50
mA
IOK
Output clamp current, (VO < 0 or VO > VCC)
±50
mA
IO
Continuous output current (VO = 0 to VCC)
±50
mA
ICC
Continuous current through each VCC or GND
±100
mA
RθJA
Thermal impedance,
junction-to-ambient (4)
RθJC
Thermal resistance, junction-to-case (4)
Tstg
Storage temperature range
(1)
(2)
(3)
(4)
No airflow
39.8
Airflow 150 ft/min
34.1
Airflow 250 ft/min
33.6
Airflow 500 ft/min
32.5
No airflow
14.5
K/W
°C
–65 to 150
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
This value is limited to 2.5 V maximum.
The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS (1)
MIN
NOM
Supply voltage
VREF
Reference voltage
VTT
Termination voltage
VI
Input voltage
VIH
AC high-level input voltage
Data inputs, CSR, PAR_IN
VIL
AC low-level input voltage
Data inputs, CSR, PAR_IN
VIH
DC high-level input voltage
Data inputs, CSR, PAR_IN
VIL
DC low-level input voltage
Data inputs, CSR, PAR_IN
VIH
High-level input voltage
RESET, Cn
VIL
Low-level input voltage
RESET, Cn
VICR
Common-mode input voltage range
CLK, CLK
0.675
VI(PP)
Peak-to-peak input voltage
CLK, CLK
600
IOH
High-level output current
Q outputs, PPO
–8
Q outputs, PPO
8
IOL
Low-level output current
TA
Operating free-air temperature
(1)
14
1.7
MAX
VCC
UNIT
1.9
V
0.49 × VCC
0.5 × VCC
0.51 × VCC
V
VREF–40 mV
VREF
VREF + 40 mV
V
VCC
V
0
VREF + 250 mV
V
VREF–250 mV
VREF + 125 mV
V
VREF–125 mV
0.65 × VCC
1.125
V
V
mV
30
-40
V
V
0.35 × VCC
QERR output
V
85
mA
mA
°C
The RESET and Cn inputs of the device must be held at valid logic voltage levels (not floating) to ensure proper device operation. The
differential inputs must not be floating unless RESET is low. See the TI application report, Implications of Slow or Floating CMOS Inputs
(SCBA004).
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOH
Q outputs, PPO
Q outputs, PPO
VOL
QERR output
PAR_IN
II
IOZ
ICC
ICCD
IOL = 100 µA
TYP (1)
MAX
VCC–0.2
UNIT
V
1.3
1.7V to 1.9V
0.2
1.7V
0.4
IOL = 25 mA
1.7V
0.5
1.9V
25
VI = GND
V
-5
VI = VCC
VO = VCC or GND
RESET = GND
Static operating
RESET = VCC, VI = VIH(AC) or
VIL(AC)
Dynamic operating – clock
only
RESET = VCC, VI = VIH(AC) or
VIL(AC), CLK and CLK switching
50% duty cycle
Chip-select-enabled
low-power active mode –
1:2 configuration
MIN
IOL = 6 mA
Static standby
Chip-select-enabled
ICCDLP low-power active mode 1:1 configuration
(1)
(2)
1.7V
QERR output
Chip-select-enabled
low-power active mode –
clock only
1.7V to 1.9V
IOH = –6 mA
VI = VCC or GND
Dynamic operating – per
each data input, 1:1
configuration
VCC
IOH = –100 µA
All other inputs (2)
Dynamic operating – per
each data input, 1:2
configuration
CI
TEST CONDITIONS
RESET = VCC, VI = VIH(AC) or
VIL(AC), CLK and CLK switching
50% duty cycle, one data input
switching at one-half clock
frequency, 50% duty cycle
1.9V
IO = 0
1.9V
Data inputs, CSR, PAR_IN
VI = VREF ± 250 mV
CLK, CLK
VICR = 0.9 V, VI(PP) = 600 mV
RESET
VI = VCC or GND
±10
µA
200
µA
40
mA
µA/MHz
45
IO = 0
1.8V
43
µA clock
MHz/
D input
60
RESET = VCC, VI = VIH(AC) or
VIL(AC), CLK and CLK switching
50% duty cycle
RESET = VCC, VI = VIH(AC) or
VIL(AC), CLK and CLK switching
50% duty cycle, one data input
switching at one-half clock
frequency, 50% duty cycle
µA
±5
µA/MHz
45
IO = 0
1.8V
2
µA clock
MHz/
D input
3
2.5
1.8V
3
2
3.5
3
pF
4
All typical values are at VCC = 1.8 V, TA = 25°C.
Each VREF pin (A3 or T3) should be tested independently, with the other (untested) pin open.
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
15
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 2 and
(1)
VCC = 1.8 V ± 0.1 V
MIN
MAX
fclock
Clock frequency
tw
Pulse duration, CLK, CLK high or low
tact
Differential inputs active time (2)
10
ns
tinact
Differential inputs inactive time (3)
15
ns
tsu
Setup time
th
(1)
(2)
(3)
Hold time
410
UNIT
1
DCS before CLK↑, CLK↓, CSR high; CSR before CLK↑, CLK↓, DCS high
600
DCS before CLK↑, CLK↓, CSR low
500
DODT, DCKE, and Data before CLK↑, CLK↓
500
PAR_IN before CLK↑, CLK↓
500
DCS, DODT, DCKE, and Data after CLK↑, CLK↓
400
PAR_IN after CLK↑, CLK↓
400
MHz
ns
ps
ps
All inputs slew rate is 1 V/ns ± 20%.
VREF must be held at a valid input level, and data inputs must be held low for a minimum time of tact max, after RESET is taken high.
VREF, data, and clock inputs must be held at valid voltage levels (not floating) for a minimum time of tinact max, after RESET is taken low.
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
FROM
(INPUT)
PARAMETER
TO
(OUTPUT)
VCC = 1.8 V ± 0.1 V
MIN
MAX
fmax
See Figure 2
tpdm
Production test, See Figure 1
CLK and CLK
Q
0.4
0.8
ns
tpd
See Figure 5
CLK and CLK
PPO
0.6
1.6
ns
1.2
2.4
1
2.0
tPLH
See Figure 4
tPHL
tRPHL (1)
See Figure 2
tRPHL
See Figure 5
tRPLH
See Figure 5
(1)
410
UNIT
CLK and CLK
RESET
RESET
QERR
MHz
Q
3
PPO
3
QERR
3
ns
ns
ns
Includes 350-ps test-load transmission-line delay.
OUTPUT SLEW RATES
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 2)
(1)
16
PARAMETER
FROM
TO
dV/dt_r
20%
dV/dt_f
80%
dV/dt_Δ (1)
20% or 80%
80% or 20%
VCC = 1.8 V ± 0.1 V
UNIT
MIN
MAX
80%
1
4
V/ns
20%
1
4
V/ns
1
V/ns
Difference between dV/dt_r (rising edge rate) and dV/dt_f (falling edge rate).
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
PARAMETER MEASUREMENT INFORMATION
VCC/2
VCC/2
VCC/2
VCC/2
VCC/2
Figure 1. Output Load For Production Test
PROPAGATION DELAY (Design Goal as per JEDEC Specification)
(1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tpdm (1)
CLK and CLK
Q
tpdmss (1)
CLK and CLK
Q
VCC = 1.8 V ± 0.1 V
UNIT
MIN
MAX
1.1
1.5
ns
1.6
ns
Includes 350 psi test-load transmission delay line
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
17
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Figure 2. Data Output Load Circuit and Voltage Waveforms
18
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Figure 3. Data Output Slew-Rate Measurement Information
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
19
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Figure 4. Error Output Load Circuit and Voltage Waveforms
20
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Figure 5. Partial-Parity-Out Load Circuit and Voltage Waveforms
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
21
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
APPLICATION INFORMATION
The typical values below are for standard raw cards. Test equipment used was the JEDEC register validation
board using pattern 0x43, 0x4F, and 0x5A.
Table 1. Raw Card Values
RAW CARD
(1)
(2)
(1) (2)
tpdmss
OVERSHOOT
MIN
MAX
A/F
1.2 ns
1.6 ns
140 mV
B/G
1.3 ns
2.0 ns
430 mV
C/H
1.3 ns
2.0 ns
430 mV
All values are valid under nominal conditions and minimum/maximum of typical signals on one typical
DIMM.
Measurements include all jitter and ISI effects.
SN74SSTUB32866 Used as a Single Device in the 1:1 Register Configuration; C0 = 0, C1 = 0
22
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for SN74SSTUB32866 Used as a Single Device; C0 = 0, C1 = 0 (RESET
Switches From L to H)
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
23
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for SN74SSTUB32866 Used as a Single Device; C0 = 0, C1 = 0 (RESET = H)
24
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for SN74SSTUB32866 Used as a Single Device; C0 = 0, C1 = 0 (RESET
Switches From = H to L)
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
25
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
SN74SSTUB32866 Used in Pair in the 1:2 Register Configuration
26
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for the First SN74SSTUB32866 (1:2 Register-A Configuration) Device Used in
Pair; C0 = 0, C1 = 1 (RESET Switches From L to H)
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
27
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for the First SN74SSTUB32866 (1:2 Register-A Configuration) Device Used in
Pair; C0 = 0, C1 = 1 (RESET = H)
28
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for the First SN74SSTUB32866 (1:2 Register-A Configuration) Device Used in
Pair; C0 = 0, C1 = 1 (RESET = Switches From H to L)
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
29
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for the Second SN74SSTUB32866 (1:2 Register-B Configuration) Device Used
in Pair; C0 = 1, C1 = 1 (RESET = Switches From L to H)
30
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for the Second SN74SSTUB32866 (1:2 Register-B Configuration) Device Used
in Pair; C0 = 1, C1 = 1 (RESET = H)
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
Submit Documentation Feedback
31
SN74SSTUB32866
www.ti.com
SCAS792C – OCTOBER 2006 – REVISED NOVEMBER 2007
Timing Diagram for the Second SN74SSTUB32866 (1:2 Register-B Configuration) Device Used
in Pair; C0 = 1, C1 = 1 (RESET = Switches From H to L)
32
Submit Documentation Feedback
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s): SN74SSTUB32866
PACKAGE OPTION ADDENDUM
www.ti.com
15-Apr-2017
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
MSL Peak Temp
(2)
(6)
(3)
Op Temp (°C)
Device Marking
(4/5)
HPA00322ZWLR
ACTIVE
BGA
ZWL
96
1000
Green (RoHS
& no Sb/Br)
SNAGCU
Level-3-260C-168 HR
-40 to 85
SB866
SN74SSTUB32866ZKER
ACTIVE
LFBGA
ZKE
96
1000
Green (RoHS
& no Sb/Br)
SNAGCU
Level-3-260C-168 HR
-40 to 85
SB866
SN74SSTUB32866ZWLR
ACTIVE
BGA
ZWL
96
1000
Green (RoHS
& no Sb/Br)
SNAGCU
Level-3-260C-168 HR
-40 to 85
SB866
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5)
Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6)
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
Addendum-Page 1
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
15-Apr-2017
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
12-May-2017
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
SN74SSTUB32866ZKER
LFBGA
ZKE
96
1000
330.0
24.4
5.7
13.7
2.0
8.0
24.0
Q1
SN74SSTUB32866ZWLR
BGA
ZWL
96
1000
330.0
24.4
5.7
13.7
2.0
8.0
24.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
12-May-2017
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
SN74SSTUB32866ZKER
SN74SSTUB32866ZWLR
LFBGA
ZKE
96
1000
336.6
336.6
31.8
BGA
ZWL
96
1000
336.6
336.6
31.8
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its
semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers
should obtain the latest relevant information before placing orders and should verify that such information is current and complete.
TI’s published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated
circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and
services.
Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is
accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced
documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements
different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the
associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Buyers and others who are developing systems that incorporate TI products (collectively, “Designers”) understand and agree that Designers
remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have
full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products
used in or for Designers’ applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with
respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous
consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and
take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will
thoroughly test such applications and the functionality of such TI products as used in such applications.
TI’s provision of technical, application or other design advice, quality characterization, reliability data or other services or information,
including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to
assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any
way, Designer (individually or, if Designer is acting on behalf of a company, Designer’s company) agrees to use any particular TI Resource
solely for this purpose and subject to the terms of this Notice.
TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI
products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections,
enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically
described in the published documentation for a particular TI Resource.
Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that
include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE
TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY
RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or
endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
TI RESOURCES ARE PROVIDED “AS IS” AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR
REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO
ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL
PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM,
INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF
PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL,
DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN
CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949
and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements.
Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such
products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards
and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must
ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in
life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use.
Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life
support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all
medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S.
TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product).
Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications
and that proper product selection is at Designers’ own risk. Designers are solely responsible for compliance with all legal and regulatory
requirements in connection with such selection.
Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer’s noncompliance with the terms and provisions of this Notice.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2017, Texas Instruments Incorporated
Similar pages