Melexis MLX90816 Discrete absolute pressure sensor Datasheet

MLX90816
Discrete Absolute Pressure Sensor
1.
Features and Benefits
2.
 High sensitivity
 Outstanding linearity
 High stability and reliability
 0 – 30..50Bar Absolute pressure sensor
 Fully automotive qualified beyond
AEC-Q100 requirements
 Compact design
3.
 Automotive applications:
•
•
Engine/Transmission oil pressure
HVAC pressure
 Multi-Market:
•
•
•
•
•
•
HVAC/Refrigeration
Industrial process controls
Appliance
Consumer electronics
Ships and marine systems
Medical instruments
Ordering Information
Temperature
Code
Product Code
MLX90816
Legend:
Temperature Code:
Package Code:
Option Code:
Packing Form:
Ordering example:
4.
Application Examples
L
Package Code
UF
Option Code
ABA-000
Packing Form
Code
WB
L(-40°C to 150°C)
UF=Die on Foil
ABA-000
WB = Wafer Box
MLX90816LUF-ACA-000-WB
Functional Diagram
5.
Figure 4-1 Functional block diagram MLX90816
3901090816
Rev 1
Page 1 of 6
General Description
The MLX90816 discrete micromachined
absolute pressure sensors has been
designed for an optimal performance when
sensing pressures from 0 to 30..50 bar
absolute. This device is fully automotive
qualified. It can directly be used in non
corrosive/non aggressive media applications.
For harsh media, the MLX90816 can be used
in a fluid filled module design. The sensor is
a piezoresistive wheatstone bridge on a
membrane
made
with
a
silicon
micromachining process. As pressure is
applied on the membrane a differential
voltage change is seen across the
Wheatstone bridge outputs while a bias
voltage is applied to the bridge inputs.
The MLX90816 can be used in combination
with the Melexis sensor interfaces ICs that
can perform the conditioning of the bridge
signal
(MLX90328,
MLX90329).
Data Sheet
Dec 2014
MLX90816
Discrete Absolute Pressure Sensor
6.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Table of Contents
Features and Benefits ...................................................................................................................................................................... 1
Application Examples....................................................................................................................................................................... 1
Ordering Information ........................................................................................................................................................................ 1
Functional Diagram .......................................................................................................................................................................... 1
General Description ......................................................................................................................................................................... 1
Table of Contents ............................................................................................................................................................................ 2
Absolute Maximum Ratings ............................................................................................................................................................. 3
Die Information ................................................................................................................................................................................ 3
General Electrical Specifications ...................................................................................................................................................... 4
Application Information ................................................................................................................................................................ 4
Standard information regarding manufacturability of Melexis products with different soldering processes .................................... 5
ESD Precautions ......................................................................................................................................................................... 5
Disclaimer ................................................................................................................................................................................... 6
Contact Information ..................................................................................................................................................................... 6
3901090816
Rev 1
Page 2 of 6
Data Sheet
Dec 2014
MLX90816
Discrete Absolute Pressure Sensor
7.
Absolute Maximum Ratings
Sym
bol
Parameter
Supply Voltage (overvoltage)
Operating Temperature Range
Storage Temperature Range
Burst Pressure
V
T
T
Min Value
Max Value
-40
- 55
10
150
150
200
Table 1: Absolute maximum ratings
Units
V
°C
°C
Bar
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximum
rated conditions for extended periods may affect device reliability.
8.
Die Information
Figure 2 Chip Dimensions and bond pad positions (all dim. in μm)
Bond Pads opening size (x, y) in
um
(330,155)
Bond
Pad
Die thickness (μm)
700
Function / Description
Vexc +
Supply voltage
Vout +
Positive output voltage
Vout -
Negative output voltage
Vexc -
Ground connection
Table 2: Bond pads description
3901090816
Rev 1
Page 3 of 6
Data Sheet
Dec 2014
MLX90816
Discrete Absolute Pressure Sensor
9.
General Electrical Specifications
o
DC Operating Parameters TA = 25 C, VDD = 5V, Pressure = 50 bar Full Scale unless otherwise specified.
Symbol
Min
Max
Units
Sensitivity
Parameter
S
0.42
.58
mV/V/bar
Bridge Resistance
Rb
3
5.5
kΩ
Offset
O
-30
30
mV
Non linearity (best fit)
NL
-0.2
0.2
%FS
Thermal Hysteresis
Hyst
-0.2
0.2
%FS
Thermal coefficient of
Span
TCS
-0.23
-0.15
%FS/˚C
Thermal coefficient of
Offset
TCO
-0.06
0.06
%FS/˚C
Thermal coefficient of
bridge resistance
TCR
0.30
0.40
%FS/˚C
Table 3: Electrical specifications
The MLX90816 can also be used with full scale pressures other than 50bar (30 to 50bar). Contact Melexis for
detailed information on the IC performance at different full scale pressures.
10.
Application Information
The MLX90816 is a very reliable discrete absolute pressure sensor fully automotive qualified. Like all Melexis
pressure sensors it has been qualified beyond typical semiconductors qualification standards. For harsh
media applications the MLX90816 can be used in a fluid filled housing.
If the application requires an amplified conditioned output the MLX90816 can be used in combination with
Melexis sensor interfaces IC like the MLX90328 and the MLX90329. By programming some calibration
settings in the sensor interface IC the sensitivity and offset variations from part to part as well as their
variations over temperature can be compensated for.
3901090816
Rev 1
Page 4 of 6
Data Sheet
Dec 2014
MLX90816
Discrete Absolute Pressure Sensor
11.
Standard information regarding manufacturability of Melexis products with
different soldering processes
Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity level
according to following test methods:
Reflow Soldering SMD’s (Surface Mount Devices)
• IPC/JEDEC J-STD-020
Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices
(classification reflow profiles according to table 5-2)
• EIA/JEDEC JESD22-A113
Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing
(reflow profiles according to table 2)
Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
• EN60749-20
Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat
• EIA/JEDEC JESD22-B106 and EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Iron Soldering THD’s (Through Hole Devices)
• EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
• EIA/JEDEC JESD22-B102 and EN60749-21
Solderability
For all soldering technologies deviating from above mentioned standard conditions (regarding peak
temperature, temperature gradient, temperature profile etc) additional classification and qualification tests
have to be agreed upon with Melexis.
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of
adhesive strength between device and board.
Melexis recommends reviewing on our web site the General Guidelines soldering recommendation
(http://www.melexis.com/Quality_soldering.aspx) as well as trim&form recommendations
(http://www.melexis.com/Assets/Trim-and-form-recommendations-5565.aspx).
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more
information on qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of
the use of certain Hazardous Substances) please visit the quality page on our website:
http://www.melexis.com/quality.aspx
12.
ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
3901090816
Rev 1
Page 5 of 6
Data Sheet
Dec 2014
MLX90816
Discrete Absolute Pressure Sensor
13.
Disclaimer
Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in its
Term of Sale. Melexis makes no warranty, express, statutory, implied, or by description regarding the
information set forth herein or regarding the freedom of the described devices from patent infringement.
Melexis reserves the right to change specifications and prices at any time and without notice. Therefore, prior
to designing this product into a system, it is necessary to check with Melexis for current information. This
product is intended for use in normal commercial applications. Applications requiring extended temperature
range, unusual environmental requirements, or high reliability applications, such as military, medical lifesupport or life-sustaining equipment are specifically not recommended without additional processing by
Melexis for each application.
The information furnished by Melexis is believed to be correct and accurate. However, Melexis shall not be
liable to recipient or any third party for any damages, including but not limited to personal injury, property
damage, loss of profits, loss of use, interrupt of business or indirect, special incidental or consequential
damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical
data herein. No obligation or liability to recipient or any third party shall arise or flow out of Melexis’ rendering
of technical or other services.
© 2014 Melexis NV. All rights reserved.
14.
Contact Information
For the latest version of this document, go to our website at
www.melexis.com
Or for additional information contact Melexis Direct:
Europe, Africa, Asia:
America:
Phone: +32 1367 0495
E-mail:
[email protected]
Phone: +1 248 306 5400
E-mail:
[email protected]
ISO/TS 16949 and ISO14001 Certified
3901090816
Rev 1
Page 6 of 6