Vitec ILPA35JU-S290ST 35w water-proof constant current led driver Datasheet

ILPA35JU SERIES
35W Water-Proof Constant Current LED Driver
–
–
–
–
–
–
–
3 Year Warranty
Wide Input Voltage 90 to 305VAC, 47 to 63Hz
Constant Current Output
High Efficiency (up to 88%)
Active Power Factor Correction (PFC)
Over Voltage, Short Circuit, Lighting, and Over Temperature Protection
IP67 Waterproof Rating, Metal Housing
Comply with UL8750 & EN61347 Safety Regulation
Approvals:
Single Output
Output Current Range
Output Voltage Range
Efficiency
Part Number
(Min. / Typ. / Max.)
(Min. / Max.)
(220VAC, Full Load)
ILPA35JU-S290ST
2755 / 2900 / 3045 mA
4 / 12 VDC
82%
ILPA35JU-S245ST
2328 / 2450 / 2573 mA
5 / 15 VDC
83%
ILPA35JU-S210ST
1995 / 2100 / 2205 mA
6 / 18 VDC
84%
ILPA35JU-S175ST
1663 / 1750 / 1838 mA
7 / 20 VDC
84%
ILPA35JU-S140ST
1330 / 1400 / 1470 mA
8 / 24 VDC
85%
ILPA35JU-S105ST
998 / 1050 / 1103 mA
11 / 33 VDC
86%
ILPA35JU-S070ST
665 / 700 / 735 mA
17 / 50 VDC
86%
ILPA35JU-S045ST
428 / 450 / 473 mA
26 / 78 VDC
87%
ILPA35JU-S035ST
333 / 350 / 368 mA
33 / 100 VDC
88%
Item -S290ST, -S245ST, -S210ST, -S175ST, -S140ST, -S105ST are Class 2 output (USR & CNR).
Item -S070ST is Class 2 output (USR), Non-Class 2 output (CNR)
Item -S045ST, -S035ST is Non-Class 2 output (USR & CNR)
Over Voltage Protection
(Min/Typ/Max)
13 / 15 / 17 VDC
16 / 18 / 20 VDC
19 / 21 / 23 VDC
23 / 25 / 27 VDC
30 / 32 / 34 VDC
39 / 41 / 43 VDC
57 / 58 / 59 VDC
95 / 97 / 99 VDC
118 / 120 / 122 VDC
Max.
Output Power
35W
35W
35W
35W
35W
35W
35W
35W
35W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Test Conditions
Operating Voltage
Min.
90
47
0
Typ.
Max.
305
63
35
0.49
0.25
20
Unit
VAC
Hz
W
A
A
A
%
%
W
%
%
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Vin=110VAC
92
Io=Full Load, Vin=230VAC
82
88
No Load, VIn=230VAC
6
Io=Full Load
2
Vin=230VAC
5
(Latch mode. The power unit shall return to normal operation only after the power is turn-on again.)
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=110VAC
1.7
2
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
10
% Vo
uF electrolytic capacitor.
Conditions
Parameter
Test Conditions
Operating Temperature
Humidity: 10% RH to 100% RH
Storage Temperature
Humidity: 5% RH to 100% RH
MTBF (Operation temperature at 25°C, calculated per MIL-HDBK-217F )
Life Time (measured at 110VAC, 45°C ambient temperature, 80% load for 2900mA output model)
No output power derating from -35°C to 55°C
Min.
-35
-40
0.541M
0.087M
Typ.
Max.
55
85
Approvals and Compliance
Parameter
EMI
EMS
Safety UL/c-UL, CE
Waterproof
Standards
EN55015
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3 , EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11, EN61547
UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1,
CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13
IP67 Rating
Mechanical & Technical
Parameter
Dimension,
Net Weight
Specification
172x34.5x42.5mm (6.77x1.36x1.67 inches)
480g approx.
Notes:
1. For the driver to operate properly, the load voltage must be
maintained above the minimum voltage threshold (approx. 33%
of the max. output voltage for any given model).
2. If the input voltage is within 90-175Vac, the output current can be
varied from 100% down to 10%. (Refer to right figure A)
3. If the input voltage is within 175-305Vac, the output current can
be varied from 100% down to 20%. (Refer to right figure B)
Unit
°C
°C
Hours
Hours
Similar pages