NID60 20 ~ 60W DC-DC Non-isolated Single Output Converter series Features : Economical open frame design Wide input range High efficiency up to 96% Built-in remote ON / OFF control Compact size 2.0" 1.024" 0.421"(SIP package) Cooling by free air convection Protections: Short circuit / Overload / Over voltage 100% burn-in test Low cost / High reliability 2 years warranty SPECIFICATION ORDER NO. OUTPUT NID60S24-05 NID60S24-12 5V 12V 15V 24V CURRENT RANGE 0 ~ 4A 0 ~ 4A 0 ~ 4A 0 ~ 2.5A RATED POWER 20W 48W 60W 60W 120mVp-p 150mVp-p 200mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p LINE REGULATION Note.3 0.5% LOAD REGULATION 0.5% Note.4 2.0% SWITCHING FREQUENCY (Typ.) 250KHz EXTERNAL CAPACITANCE LOAD (max.) 100uF / 25V low ESR 68uf/16V low ESR 47uf/50V low ESR VOLTAGE RANGE NORMAL VOLTAGE 20 ~ 53VDC 24VDC (or 48VDC) 20 ~ 53VDC 20 ~ 53VDC 24VDC (or 48VDC) 24VDC (or 48VDC) 48VDC EFFICIENCY (Typ.) 90% 95% 96% 95% Full load 940mA 2120mA 2610mA 1320mA No load 30mA 30mA 50mA DC CURRENT 20mA 30 ~ 53VDC Fuse recommended (5A) 120 ~ 300% rated output power PROTECTION OVERLOAD (Typ.) Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with short circuit PROTECTION SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Shut off o/p voltage, clamp by TVS diode OVER VOLTAGE -25 ~ +65 20% ~ 85% WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -25 ~ +105 0.03% / TEMP. COEFFICIENT WORKING TEMP. OTHERS NID60S48-24 DC VOLTAGE VOLTAGE ACCURACY INPUT NID60S24-15 (Refer to output load derating curve) RH non-condensing , 10 ~ 85% RH (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes REMOTE CONTROL DIMENSION Power on : 3.3VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6 & PIN11) 50.8*26*10.7mm or 2.0"*1.024"*0.421" inch (L*W*H) WEIGHT 15g Derating Curve Pin Configuration Mechanical Specification Unit:mm(inch) 8 [0.315] 6 7 8 9 1011 0.64 [0.025] 10.16 [0.40] 25.4 [1] 26 [1.024] 3.6+1/-0 [0.142] 1 2 3 4 5 1.3 [0.051] SIDE VIEW Pin No. Output 1,2,3,4 5,6 7,8 9,10 11 + Vo u t Com + Vi n N.C. R.C. 100 LOAD (%) 10.7[0.421]max. 50.8 [2] 80 50 5.6 [0.22] 2.54 [0.1] -25 0 25 50 60 65 Ta ( NOTE 100 ) 1.All parameters are specified at normal input, rated load, 25 70% RH Ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. File Name:NID60-SPEC 2009-09-04