Order Now Product Folder Support & Community Tools & Software Technical Documents ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 ADS114S0xB Low-Power, Low-Noise, Highly Integrated, 6- and 12-Channel, 4-kSPS, 16-Bit, Delta-Sigma ADC With PGA and Voltage Reference 1 Features 3 Description • • • • The ADS114S06B and ADS114S08B are precision, 16-bit, delta-sigma (ΔΣ), analog-to-digital converters (ADCs) that offer low power consumption and many integrated features to reduce system cost and component count in applications measuring smallsignal sensors. 1 • • • • • • • • • • • • Low Power Consumption: As Low as 280 µA Programmable Gain: 1 to 128 Programmable Data Rates: 2.5 SPS to 4 kSPS Simultaneous 50-Hz and 60-Hz Rejection at ≤ 20 SPS With Low-Latency Digital Filter Analog Multiplexer with 12 (ADS114S08B) or 6 (ADS114S06B) Independently Selectable Inputs Dual-Matched Programmable Current Sources for Sensor Excitation: 10 µA to 2000 µA Internal Reference: 2.5 V, 8 ppm/°C (typ) Drift Internal Oscillator: 4.096 MHz, 2% Accuracy Internal Temperature Sensor Self Offset and System Calibration Four General-Purpose I/Os SPI-Compatible Interface Analog Supply: Unipolar (2.7 V to 5.25 V) or Bipolar (±2.5 V) Digital Supply: 2.7 V to 3.6 V Operating Temperature: –40°C to +125°C Pin-Compatible With the ADS114S0x These ADCs feature a digital filter that offers lowlatency conversion results and 50-Hz or 60-Hz rejection for noisy industrial environments. A lownoise, programmable gain amplifier (PGA) provides gains ranging from 1 to 128 to amplify low-level signals for resistive bridge or thermocouple applications. Additionally, these devices integrate a low-drift, 2.5-V reference that reduces printed circuit board (PCB) area. Finally, two programmable excitation current sources (IDACs) allow for easy and accurate RTD biasing. An input multiplexer supports 12 inputs for the ADS114S08B and six inputs for the ADS114S06B that can be connected to the ADC in any combination for design flexibility. In addition, these devices include features such as sensor burn-out detection, voltage bias for thermocouples, system monitoring, and four general-purpose I/Os. The devices are offered in a leadless VQFN-32 or a TQFP-32 package. 2 Applications • • • • Sensor Transducers and Transmitters: Temperature, Pressure, Strain, Flow PLC and DCS Analog Input Modules Temperature Controllers Climate Chambers, Industrial Ovens Device Information ORDER NUMBER ADS114S0xB PACKAGE (PIN) BODY SIZE TQFP (32) 5.0 mm × 5.0 mm VQFN (32) 5.0 mm × 5.0 mm Functional Block Diagram AVDD REFN0 Burnout Detect Excitation Current Sources AINCOM AIN0 REFP0 Reference Mux REFCOM REFOUT DVDD 2.5-V Reference ADS114S06B ADS114S08B IOVDD AIN1 AIN2 Reference Buffers VBIAS AIN3 AIN4 AIN5 Input Mux PGA AIN6 / REFP1 16-Bit û ADC START/SYNC Configurable Digital Filter Serial Interface and Control AIN7 / REFN1 SCLK DIN AIN8 / GPIO0 DOUT/DRDY AIN9 / GPIO1 Power Supplies AIN10 / GPIO2 Temperature Sensor AIN11 / GPIO3 ADS114S08B Only RESET CS Burnout Detect AVSS System-, SelfCalibration DRDY 4.096-MHz Oscillator CLK DGND Copyright © 2017, Texas Instruments Incorporated 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Table of Contents 1 2 3 4 5 6 7 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Device Family Comparison Table ........................ Pin Configuration and Functions ......................... Specifications......................................................... 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 9.6 Register Map........................................................... 54 1 1 1 2 3 3 5 10 Application and Implementation........................ 67 10.1 Application Information.......................................... 67 10.2 Typical Application ................................................ 72 10.3 Do's and Don'ts ..................................................... 77 11 Power Supply Recommendations ..................... 79 11.1 11.2 11.3 11.4 Absolute Maximum Ratings ..................................... 5 ESD Ratings.............................................................. 5 Recommended Operating Conditions....................... 6 Thermal Information .................................................. 6 Electrical Characteristics........................................... 7 Timing Characteristics............................................. 10 Switching Characteristics ........................................ 10 Typical Characteristics ............................................ 13 8 Parameter Measurement Information ................ 19 9 Detailed Description ............................................ 21 Overview ................................................................. Functional Block Diagram ....................................... Feature Description................................................. Device Functional Modes........................................ Programming........................................................... 79 79 79 79 12 Layout................................................................... 80 12.1 Layout Guidelines ................................................. 80 12.2 Layout Example .................................................... 81 13 Device and Documentation Support ................. 82 13.1 13.2 13.3 13.4 13.5 13.6 13.7 13.8 8.1 Noise Performance ................................................. 19 9.1 9.2 9.3 9.4 9.5 Power Supplies ..................................................... Power-Supply Sequencing.................................... Power-On Reset.................................................... Power-Supply Decoupling..................................... 21 22 23 42 46 Device Support...................................................... Documentation Support ........................................ Related Links ........................................................ Receiving Notification of Documentation Updates Community Resources.......................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 82 82 82 82 82 82 82 83 14 Mechanical, Packaging, and Orderable Information ........................................................... 83 4 Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. 2 DATE REVISION NOTES August 2017 * Initial release. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 5 Device Family Comparison Table PRODUCT RESOLUTION (Bits) NUMBER OF INPUTS ADS114S08B 16 12 analog inputs ADS114S06B 16 6 analog inputs 6 Pin Configuration and Functions RHB Package 32-Pin VQFN Top View REFOUT AIN4 3 22 GPIO0/AIN8 AIN3 4 21 AIN2 5 AIN1 AIN0 REFN0 AVSS AVSS AVDD NC 27 26 25 GPIO0/AIN8 GPIO1/AIN9 AIN3 4 21 GPIO1/AIN9 20 GPIO2/AIN10 AIN2 5 20 GPIO2/AIN10 6 19 GPIO3/AIN11 AIN1 6 19 GPIO3/AIN11 7 18 RESET AIN0 7 18 RESET START/SYNC 8 17 CLK DVDD DGND IOVDD DRDY CS Not to scale DOUT/DRDY 16 DVDD CLK 9 15 13 DRDY 14 12 DOUT/DRDY DGND 11 IOVDD 10 DIN SCLK 17 9 8 SCLK Pad DIN Thermal 16 22 15 3 14 REFOUT AIN4 13 REFCOM 23 12 24 2 11 1 AIN5 10 AINCOM CS START/SYNC 28 NC 25 23 REFP0 AVDD 26 2 29 AVSS 27 AIN5 REFN1/AIN7 AVSS 28 REFCOM 30 REFN0 29 24 REFP1/AIN6 REFP0 30 1 31 REFN1/AIN7 31 AINCOM 32 REFP1/AIN6 32 PBS Package 32-Pin TQFP Top View Not to scale NOTE: The analog input functions (AIN6–AIN11) are not available on pins 19 to 22, 31, and 32 for the ADS114S06B. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 3 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Pin Functions PIN NO. DESCRIPTION (1) NAME FUNCTION 1 AINCOM Analog input Common analog input for single-ended measurements 2 AIN5 Analog input Analog input 5 3 AIN4 Analog input Analog input 4 4 AIN3 Analog input Analog input 3 5 AIN2 Analog input Analog input 2 6 AIN1 Analog input Analog input 1 7 AIN0 Analog input Analog input 0 8 START/SYNC Digital input Start conversion 9 CS Digital input Chip select; active low 10 DIN Digital input Serial data input 11 SCLK Digital input Serial clock input 12 DOUT/DRDY Digital output Serial data output combined with data ready; active low 13 DRDY Digital output Data ready; active low 14 DGND Digital ground Digital ground 15 IOVDD Digital supply Digital I/O power supply. In case IOVDD is not tied to DVDD, connect a 100-nF (or larger) capacitor to DGND. 16 DVDD Digital supply Digital core power supply. Connect a 100-nF (or larger) capacitor to DGND. 17 CLK Digital input External clock input. Connect to DGND to use the internal oscillator. 18 RESET Digital input Reset; active low 19 GPIO3/AIN11 Analog input/output General-purpose I/O (2); analog input 11 (ADS114S08B only) 20 GPIO2/AIN10 Analog input/output General-purpose I/O (2); analog input 10 (ADS114S08B only) 21 GPIO1/AIN9 Analog input/output General-purpose I/O (2); analog input 9 (ADS114S08B only) 22 GPIO0/AIN8 Analog input/output General-purpose I/O (2); analog input 8 (ADS114S08B only) 23 REFOUT Analog output Positive voltage reference output. Connect a 1-µF to 47-µF capacitor to REFCOM if the internal voltage reference is enabled. 24 REFCOM Analog output Negative voltage reference output. Connect to AVSS. 25 NC — 26 AVDD Analog supply Positive analog power supply. Connect a 330-nF (or larger) capacitor to AVSS. 27 AVSS Analog supply Negative analog power supply 28 AVSS Analog supply Negative analog power supply 29 REFN0 Analog input Negative external reference input 0 30 REFP0 Analog input Positive external reference input 0 31 REFN1/AIN7 Analog input Negative external reference input 1; analog input 7 (ADS114S08B only) 32 REFP1/AIN6 Analog input Positive external reference input 1; analog input 6 (ADS114S08B only) Pad Thermal Pad — (1) (2) 4 Leave unconnected or connect to AVSS RHB package only. Thermal power pad. Connect to AVSS. See the Unused Inputs and Outputs section for details on how to connect unused pins. General-purpose inputs and outputs use logic levels based on the analog supply. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 7 Specifications 7.1 Absolute Maximum Ratings (1) Power-supply voltage MIN MAX AVDD to AVSS –0.3 5.5 AVSS to DGND –2.8 0.3 DVDD to DGND –0.3 3.9 IOVDD to DGND UNIT V –0.3 5.5 Analog input voltage AINx, GPIOx, REFPx, REFNx, REFCOM AVSS – 0.3 AVDD + 0.3 V Digital input voltage CS, SCLK, DIN, DOUT/DRDY, DRDY, START, RESET, CLK DGND – 0.3 IOVDD + 0.3 V Continuous, REFN0, REFOUT –100 100 Continuous, all other pins except power-supply pins –10 10 Input current Temperature (1) Junction, TJ mA 150 Storage, Tstg –60 °C 150 Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 7.2 ESD Ratings VALUE V(ESD) (1) (2) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1) Charged-device model (CDM), per JEDEC specification JESD22-C101 (2) ±2500 ±1000 UNIT V JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 5 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 7.3 Recommended Operating Conditions over operating ambient temperature range (unless otherwise noted) MIN NOM MAX UNIT POWER SUPPLY Analog power supply AVDD to AVSS 2.7 AVSS to DGND –2.625 AVDD to DGND 1.5 Digital core power supply DVDD to DGND Digital IO power supply IOVDD to DGND 5.25 0 0.05 V 5.25 2.7 3.6 V DVDD 5.25 V ANALOG INPUTS (1) PGA bypassed PGA enabled, gain = 1 to 16 Absolute input voltage (2) V(AINx) PGA enabled, gain = 32 to 128 VIN Differential input voltage VIN = VAINP – VAINN AVSS – 0.05 AVDD + 0.05 AVSS + 0.15 + |VINMAX|·(Gain – 1) / 2 AVDD – 0.15 – |VINMAX|·(Gain –1) / 2 AVSS + 0.15 + 15.5·|VINMAX| AVDD – 0.15 – 15.5·|VINMAX| –VREF / Gain VREF / Gain V 0.5 AVDD – AVSS V V VOLTAGE REFERENCE INPUTS (3) VREF Differential reference input voltage V(REFNx) Absolute negative reference voltage Negative reference buffer disabled AVSS – 0.05 V(REFPx) – 0.5 V Negative reference buffer enabled AVSS V(REFPx) – 0.5 V V(REFPx) Absolute positive reference voltage Positive reference buffer disabled V(REFNx) + 0.5 AVDD + 0.05 V Positive reference buffer enabled V(REFNx) + 0.5 AVDD V VREF = V(REFPx) – V(REFNx) EXTERNAL CLOCK SOURCE (4) fCLK External clock frequency Duty cycle 2 4.096 4.5 40% 50% 60% MHz GENERAL-PURPOSE INPUTS (GPIOs) Input voltage AVSS – 0.05 AVDD + 0.05 V DGND IOVDD V –40 125 °C DIGITAL INPUTS (Other than GPIOs) Input voltage TEMPERATURE RANGE TA (1) (2) (3) (4) Operating ambient temperature AINP and AINN denote the positive and negative inputs of the PGA. Any of the available analog inputs (AINx) can be selected as either AINP or AINN by the input multiplexer. VINMAX denotes the maximum differential input voltage, VIN, that is expected in the application. |VINMAX| can be smaller than VREF / Gain. REFPx and REFNx denote one of the two available external differential reference input pairs. An external clock is not required when the internal oscillator is used. 7.4 Thermal Information ADS114S06B, ADS114S08B THERMAL METRIC (1) VQFN (RHB) TQFP (PBS) 32 PINS 32 PINS UNIT RθJA Junction-to-ambient thermal resistance 45.2 75.5 °C/W RθJC(top) Junction-to-case (top) thermal resistance 28.3 17.1 °C/W RθJB Junction-to-board thermal resistance 15.8 28.5 °C/W ψJT Junction-to-top characterization parameter 0.4 0.4 °C/W ψJB Junction-to-board characterization parameter 15.7 28.3 °C/W RθJC(bot) Junction-to-case (bottom) thermal resistance 2.3 n/a °C/W (1) 6 For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 7.5 Electrical Characteristics minimum and maximum specifications apply from TA = –40°C to +125°C; typical specifications are at TA = 25°C; all specifications are at AVDD = 2.7 V to 5.25 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, all gains, internal reference, internal oscillator, and all data rates (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT ANALOG INPUTS Absolute input current Differential input current PGA bypassed, AVSS + 0.1 V ≤ V(AINx) ≤ AVDD – 0.1 V ±0.5 nA PGA enabled, gain 1 to 128, V(AINx)MIN ≤ V(AINx) ≤ V(AINx)MAX –10 PGA bypassed, VCM = AVDD / 2, –VREF ≤ VIN ≤ VREF ±0.1 10 ±1 PGA enabled, gain 1 to 128, VCM = AVDD / 2, –VREF / Gain ≤ VIN ≤ VREF / Gain nA/V ±0.02 nA PGA 1, 2, 4, 8, 16, 32, 64, 128 Gain settings Startup time Enabling the PGA in conversion mode 190 µs SYSTEM PERFORMANCE Resolution (no missing codes) 16 DR Data rate INL Integral nonlinearity (best fit) PGA bypassed, VCM = AVDD / 2 1 PGA enabled, gain = 1 to 128, VCM = AVDD / 2 2 PGA bypassed Offset drift Gain error (1) Gain drift (1) NMRR Normal-mode rejection ratio (2) CMRR Common-mode rejection ratio PSRR Power-supply rejection ratio (1) (2) ppmFSR 2 PGA bypassed, after internal offset calibration On the order of noisePP at the set DR and gain PGA enabled, gain = 1 to 128, after internal offset calibration On the order of noisePP at the set DR and gain PGA bypassed 10 PGA enabled, gain = 1 to 128 15 TA = 25°C, PGA bypassed TA = 25°C, PGA enabled, gain = 1 to 128 PGA bypassed µV nV/°C 0.01% 0.1% 0.025% 0.2% 0.5 PGA enabled, gain = 1 to 128 Noise (input-referred) 25 20 / Gain PGA enabled, gain = 16 to 128 Input offset voltage SPS 20 PGA enabled, gain = 1 to 8 VIO Bits 2.5, 5, 10, 16.6, 20, 50, 60, 100, 200, 400, 800, 1000, 2000, 4000 1 ppm/°C See the Noise Performance section fIN = 50 Hz or 60 Hz (±1 Hz), DR = 20 SPS 75 fIN = 50 Hz or 60 Hz (±1 Hz), DR = 20 SPS, external fCLK = 4.096 MHz 95 95 dB At dc 120 fCM = 50 Hz or 60 Hz (±1 Hz), DR = 2.5 SPS, 5 SPS, 10 SPS, 20 SPS 125 AVDD at dc 105 AVDD at 50 Hz or 60 Hz 115 DVDD at dc 115 dB dB Excluding error of voltage reference. See the 50-Hz and 60-Hz Line Cycle Rejection section for more information. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 7 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Electrical Characteristics (continued) minimum and maximum specifications apply from TA = –40°C to +125°C; typical specifications are at TA = 25°C; all specifications are at AVDD = 2.7 V to 5.25 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, all gains, internal reference, internal oscillator, and all data rates (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VOLTAGE REFERENCE INPUTS Absolute input current Reference buffers disabled, external VREF = 2.5 V, REFP1/REFN1 inputs 4 µA/V Reference buffers enabled, external VREF = 2.5 V, REFP1/REFN1 inputs 5 nA INTERNAL VOLTAGE REFERENCE VREF Output voltage Accuracy 2.5 TA = 25°C –0.2% Temperature drift Output current PSRR 0.2% 8 40 AVDD = 2.7 V to 3.3 V, sink and source –5 5 AVDD = 3.3 V to 5.25 V, sink and source –10 10 Short-circuit current limit Sink and source 70 Power-supply rejection ratio AVDD at dc 85 Load regulation V ±0.01% AVDD = 2.7 V to 3.3 V, load current = –5 mA to 5 mA 8 AVDD = 3.3 V to 5.25 V, load current = –10 mA to 10 mA 8 Startup time 1-µF capacitor on REFOUT, 0.001% settling Capacitive load stability Capacitor on REFOUT Reference noise f = 0.1 Hz to 10 Hz, 1-µF capacitor on REFOUT 100 ppm/°C mA mA dB µV/mA 5.9 1 ms 47 µF 9 µVPP 4.096 MHz INTERNAL OSCILLATOR fCLK Frequency Accuracy –2% 2% EXCITATION CURRENT SOURCES (IDACS) 10, 50, 100, 250, 500, 750, 1000, 1500, 2000 Current settings Compliance voltage (3) µA 10 µA to 750 µA, 0.1% deviation AVSS AVDD – 0.4 1 mA to 2 mA, 0.1% deviation AVSS AVDD – 0.6 –6% ±1% V Accuracy (each IDAC) TA = 25°C, 10 µA to 2 mA Current mismatch between IDACs 6% TA = 25°C, 10 µA to 2 mA Temperature drift (each IDAC) 10 µA to 2 mA 100 ppm/°C Temperature drift matching between IDACs 10 µA to 2 mA 10 ppm/°C Startup time With internal reference already settled. From end of WREG command to current flowing out of pin. 22 µs 0.2% BIAS VOLTAGE VBIAS Output voltage Output impedance Startup time Combined capacitive load on all selected analog inputs CLOAD = 1 µF, 0.1% settling (AVDD + AVSS) / 2 V 350 Ω 2.8 ms 0.2, 1, 10 µA BURNOUT CURRENT SOURCES (BOCS) Current settings Accuracy 0.2 µA, sinking or sourcing ±8% 1 µA, sinking or sourcing ±4% 10 µA, sinking or sourcing ±2% (AVDD – AVSS) / 4 monitor ±1% DVDD / 4 monitor ±1% SUPPLY VOLTAGE MONITORS Accuracy (3) 8 The IDAC current does not change by more than 0.1% from the nominal value when staying within the specified compliance voltage. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Electrical Characteristics (continued) minimum and maximum specifications apply from TA = –40°C to +125°C; typical specifications are at TA = 25°C; all specifications are at AVDD = 2.7 V to 5.25 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, all gains, internal reference, internal oscillator, and all data rates (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT TEMPERATURE SENSOR Output voltage TA = 25°C Temperature coefficient 129 mV 403 µV/°C GENERAL-PURPOSE INPUT/OUTPUTS (GPIOs) VIL Logic input level, low VIH Logic input level, high VOL Logic output level, low VOH Logic output level, high AVSS – 0.05 0.3 AVDD V 0.7 AVDD AVDD + 0.05 V IOL = 1 mA AVSS 0.2 AVDD V IOH = 1 mA 0.8 AVDD AVDD V DIGITAL INPUT/OUTPUTS VIL Logic input level, low VIH Logic input level, high DGND 0.3 IOVDD V 0.7 IOVDD IOVDD VOL Logic output level, low V IOL = 1 mA DGND 0.2 IOVDD VOH V Logic output level, high IOH = 1 mA 0.8 IOVDD IOVDD V Input current DGND ≤ VDigital Input ≤ IOVDD –1 1 µA ANALOG SUPPLY CURRENT (AVDD = 3.3 V, External Reference, Internal Reference Disabled, Reference Buffers Disabled, IDACs Disabled, VBIAS Disabled, Internal Oscillator, All Data Rates, VIN = 0 V) IAVDD Analog supply current Power-down mode 0.1 Standby mode, PGA bypassed 70 Conversion mode, PGA bypassed 85 Conversion mode, PGA enabled, gain = 1, 2 120 Conversion mode, PGA enabled, gain = 4, 8 140 Conversion mode, PGA enabled, gain = 16, 32 165 Conversion mode, PGA enabled, gain = 64 200 Conversion mode, PGA enabled, gain = 128 250 µA ADDITIONAL ANALOG SUPPLY CURRENTS PER FUNCTION (AVDD = 3.3 V) Internal 2.5-V reference, no external load IAVDD Analog supply current 185 Positive reference buffer 35 Negative reference buffer 25 VBIAS buffer, no external load 10 IDAC overhead, 10 µA to 250 µA 20 IDAC overhead, 500 µA to 750 µA 30 IDAC overhead, 1 mA 40 IDAC overhead, 1.5 mA 50 IDAC overhead, 2 mA 65 µA DIGITAL SUPPLY CURRENT (DVDD = IOVDD = 3.3 V, All Data Rates, SPI Not Active) IDVDD + IIOVDD Digital supply current Power-down mode, internal oscillator 0.1 Standby mode, internal oscillator 185 Conversion mode, internal oscillator 225 Conversion mode, external fCLK = 4.096 MHz 195 µA POWER DISSIPATION (AVDD = DVDD = IOVDD = 3.3 V, Internal Reference Enabled, Reference Buffers Disabled, IDACs Disabled, VBIAS Disabled, Internal Oscillator, All Data Rates, VIN = 0 V, SPI Not Active) PD Power dissipation Conversion mode, PGA enabled, gain = 1 1.75 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B mW 9 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 7.6 Timing Characteristics over operating ambient temperature range, DVDD = 2.7 V to 3.6 V, IOVDD = DVDD to 5.25 V, and DOUT/DRDY load = 20 pF || 100 kΩ to DGND (unless otherwise noted) MIN MAX UNIT (1) SERIAL INTERFACE td(CSSC) Delay time, first SCLK rising edge after CS falling edge 20 ns td(SCCS) Delay time, CS rising edge after final SCLK falling edge 20 ns tw(CSH) Pulse duration, CS high 30 ns tc(SC) SCLK period 100 ns tw(SCH) Pulse duration, SCLK high 40 ns tw(SCL) Pulse duration, SCLK low 40 ns tsu(DI) Setup time, DIN valid before SCLK falling edge 15 ns th(DI) Hold time, DIN valid after SCLK falling edge 20 ns td(CMD) Delay time, between bytes or commands 0 ns tw(RSL) Pulse duration, RESET low 4 tCLK td(RSSC) Delay time, first SCLK rising edge after RESET rising edge (or 7th SCLK falling edge of RESET command) 4096 tCLK RESET PIN START/SYNC PIN tw(STH) Pulse duration, START/SYNC high 4 tCLK tw(STL) Pulse duration, START/SYNC low 4 tCLK tsu(STDR) Setup time, START/SYNC falling edge (or 7th SCLK falling edge of STOP command) before DRDY falling edge to stop further conversions (continuous conversion mode) 32 tCLK (1) tCLK = 1 / fCLK. 7.7 Switching Characteristics over operating ambient temperature range, DVDD = 2.7 V to 3.6 V, IOVDD = DVDD to 5.25 V, and DOUT/DRDY load = 20 pF || 100 kΩ to DGND (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT (1) tp(CSDO) Propagation delay time, CS falling edge to DOUT driven 0 25 ns tp(SCDO) Propagation delay time, SCLK rising edge to valid new DOUT 3 30 ns tp(CSDOZ) Propagation delay time, CS rising edge to DOUT high impedance 0 25 ns tp(STDR) Propagation delay time, START/SYNC rising edge (or first SCLK rising edge of any command or data read) to DRDY rising edge 2 tCLK tw(DRH) Pulse duration, DRDY high tp(GPIO) Propagation delay time, last SCLK falling edge of WREG command to GPIOx output valid SPI timeout per 8 bits (1) (2) 10 24 (2) 3 15 2 tCLK 100 ns tCLK tCLK = 1 / fCLK The SPI interface resets when an entire byte is not sent within the specified timeout time. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 tw(CSH) CS ttd(CSSC)t ttc(SC)t tw(SCH) ttd(SCCS)t SCLK tsu(DI) th(DI) tw(SCL) DIN NOTE: Single-byte communication is shown. Actual communication can be multiple bytes. Figure 1. Serial Interface Timing Requirements CS SCLK tp(CSDO) DOUT/DRDY tp(SCDO) tp(CSDOZ) Hi-Z Hi-Z NOTE: Single-byte communication is shown. Actual communication can be multiple bytes. Figure 2. Serial Interface Switching Characteristics tw(RSL) RESET td(RSSC) SCLK DIN RESET command New command Figure 3. RESET Pin and RESET Command Timing Requirements tw(STL) START/SYNC DRDY tw(STH) tp(STDR) tp(STDR) tw(DRH) tsu(STDR) Figure 4. START/SYNC Pin Timing Requirements Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 11 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com SCLK DIN DRDY START command STOP command tp(STDR) tp(STDR) tsu(STDR) Figure 5. START Command Timing Requirements SCLK DIN WREG WREG GPIODAT 01h 01h 01h Write two registers GPIO0 set as output GPIO0 set high GPIO0 enabled GPIO0 tp(GPIO) Figure 6. GPIO Switching Characteristics 12 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 7.8 Typical Characteristics at TA = 25°C, AVDD = 3.3 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, using internal VREF = 2.5 V, internal 4.096-MHz oscillator, and PGA enabled (unless otherwise noted) 2000 2000 25qC 85qC 125qC -40qC 1000 Absolute Input Current (pA) Absolute Input Current (pA) -40qC 0 -1000 -2000 -3000 -4000 125qC 0 -1000 -2000 -3000 0.5 1 1.5 2 V(AINx) (V) 2.5 3 3.5 0 PGA bypassed, DR = 20 SPS, VIN = 0 V 0.5 1 1.5 2 V(AINx) (V) 2.5 3 3.5 PGA bypassed, DR = 4 kSPS, VIN = 0 V Figure 7. Absolute Input Current vs Absolute Input Voltage Figure 8. Absolute Input Current vs Absolute Input Voltage 2000 2000 -40qC 25qC 85qC 125qC -40qC 25qC 85qC 125qC 1500 Absolute Input Current (pA) 1500 Absolute Input Current (pA) 85qC -4000 0 1000 500 0 -500 -1000 -1500 1000 500 0 -500 -1000 -1500 -2000 -2000 0 0.5 1 1.5 2 V(AINx) (V) 2.5 3 3.5 0 PGA enabled, gain = 1, DR = 20 SPS, VIN = 0 V 0.5 1 1.5 2 V(AINx) (V) 2.5 3 3.5 PGA enabled, gain = 1, DR = 4 kSPS, VIN = 0 V Figure 9. Absolute Input Current vs Absolute Input Voltage Figure 10. Absolute Input Current vs Absolute Input Voltage 2000 2000 -40qC 25qC 85qC 125qC -40qC 25qC 85qC 125qC 1500 Differential Input Current (pA) 1500 Differential Input Current (pA) 25qC 1000 1000 500 0 -500 -1000 -1500 1000 500 0 -500 -1000 -1500 -2000 -2.5 -2 -1.5 -1 -0.5 0 0.5 VIN (V) 1 1.5 2 2.5 PGA bypassed, DR = 20 SPS, VCM = 1.65 V Figure 11. Differential Input Current vs Differential Input Voltage -2000 -2.5 -2 -1.5 -1 -0.5 0 0.5 VIN (V) 1 1.5 2 2.5 PGA bypassed, DR = 4 kSPS, VCM = 1.65 V Figure 12. Differential Input Current vs Differential Input Voltage Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 13 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Typical Characteristics (continued) at TA = 25°C, AVDD = 3.3 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, using internal VREF = 2.5 V, internal 4.096-MHz oscillator, and PGA enabled (unless otherwise noted) 200 400 -40qC 25qC 85qC 125qC -40qC 100 50 0 -50 -100 -150 -200 -2.5 -2 -1.5 -1 -0.5 0 0.5 VIN (V) 1 1.5 2 100 0 -100 -200 -400 -2.5 2.5 -2 -1.5 -1 -0.5 0 0.5 VIN (V) 1 1.5 2 2.5 PGA enabled, DR = 4 kSPS, VCM = 1.65 V Figure 14. Differential Input Current vs Differential Input Voltage 3 3 2 2 INL (ppm of FSR) INL (ppm of FSR) 125qC -300 Figure 13. Differential Input Current vs Differential Input Voltage 1 0 -1 1 0 -1 -2 -2 -3 -100 -80 -60 -40 -20 0 20 VIN (% of FSR) 40 60 80 -3 -100 100 -80 -60 -40 -20 0 20 VIN (% of FSR) 40 60 80 100 PGA enabled, gain = 1 PGA bypassed, gain = 1 Figure 16. INL vs Differential Input Voltage Figure 15. INL vs Differential Input Voltage 16 10 Gain = 1 Gain = 2 Gain = 4 Gain = 8 Gain = 16 Gain = 32 Gain = 64 Gain = 128 14 Gain = 1 Gain = 2 Gain = 4 Gain = 8 Gain = 16 Gain = 32 Gain = 64 Gain = 128 12 Offset Voltage (PV) INL (ppm of FSR) 85qC 200 PGA enabled, DR = 20 SPS, VCM = 1.65 V 8 25qC 300 Differential Input Current (pA) Differential Input Current (pA) 150 6 4 10 8 6 4 2 2 0 -50 -25 0 25 50 Temperature (qC) 75 Figure 17. INL vs Temperature 14 100 125 0 -50 -25 0 25 50 Temperature (qC) 75 100 125 Figure 18. Offset Voltage vs Temperature Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Typical Characteristics (continued) at TA = 25°C, AVDD = 3.3 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, using internal VREF = 2.5 V, internal 4.096-MHz oscillator, and PGA enabled (unless otherwise noted) 2.502 Internal Reference Voltage (V) 0.03 Gain Error (%) 0.025 0.02 0.015 0.01 0.005 PGA disabled Gain = 1 Gain = 4 Gain = 32 2.501 2.5 2.499 2.498 Gain = 128 2.497 0 -50 -25 0 25 50 Temperature (qC) 75 100 -50 125 -25 0 25 50 Temperature (qC) 75 100 125 28 units, TQFP package Figure 20. Internal Reference Voltage vs Temperature Figure 19. Gain Error vs Temperature 2.5002 10 Internal Reference Noise (PV) Internal Reference Voltage (V) 8 2.5001 2.5 2.4999 2.4998 6 4 2 0 -2 -4 -6 -8 2.4997 2.7 3 3.3 3.6 3.9 4.2 AVDD (V) 4.5 4.8 5.1 -10 5.4 Time (1 s/div) Figure 22. Internal Reference Voltage Noise Figure 21. Internal Reference Voltage vs AVDD 4.12 Internal Oscillator Frequency (MHz) Number of Occurrences 250 200 150 100 4.106 4.104 4.102 4.1 4.098 4.096 4.094 4.092 0 4.09 50 4.11 4.1 4.09 4.08 4.07 4.06 -50 -25 25 50 Temperature (C) 75 100 125 28 units Internal Oscillator Frequency (MHz) Figure 23. Internal Oscillator Frequency Histogram 0 Figure 24. Internal Oscillator Frequency vs Temperature Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 15 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Typical Characteristics (continued) 0 0 -10 -1 IDAC Error (%) IDAC Error (%) at TA = 25°C, AVDD = 3.3 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, using internal VREF = 2.5 V, internal 4.096-MHz oscillator, and PGA enabled (unless otherwise noted) -20 -30 10 µA 50 µA 100 µA 250 µA 500 µA -40 750 µA 1 mA 1.5 mA 2 mA 0.5 1 -3 10 µA 50 µA 100 µA 250 µA 500 µA -4 -5 2.5 -50 0 -2 1.5 2 2.5 IDAC Output Voltage (V) 3 3.5 2.7 2.8 2.9 3 IDAC Output Voltage (V) 3.1 3.2 Figure 26. IDAC Accuracy vs Compliance Voltage Figure 25. IDAC Accuracy vs Compliance Voltage 3 0.3 2 10 PA 50 PA 100 PA 250 PA 500 PA 0.25 IDAC Mismatch Error (%) IDAC Error (%) 2.6 750 µA 1 mA 1.5 mA 2 mA 1 0 -1 10 PA 50 PA 100 PA 250 PA 500 PA -2 -3 -50 -25 0 25 50 Temperature (qC) 750 PA 1 mA 1.5 mA 2 mA 75 100 0.2 750 PA 1 mA 1.5 mA 2 mA 0.15 0.1 0.05 0 -50 125 -25 0 25 50 Temperature (qC) 75 100 125 IDAC output voltage = 1.65 V Figure 27. IDAC Accuracy vs Temperature Figure 28. IDAC Matching vs Temperature 180 AVDD = 2.7 V AVDD = 5.25 V (AVDD - AVSS) / 2 Ratio 0.5005 0.5 0.4995 0.499 0.4985 0.498 -50 -25 0 25 50 Temperature (qC) 75 100 Figure 29. VBIAS Voltage [(AVDD – AVSS) / 2] vs Temperature 16 125 Temperature Sensor Voltage (mV) 0.501 160 140 120 100 80 -50 -25 0 25 50 Temperature (qC) 75 100 125 Figure 30. Temperature Sensor Voltage vs Temperature Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Typical Characteristics (continued) at TA = 25°C, AVDD = 3.3 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, using internal VREF = 2.5 V, internal 4.096-MHz oscillator, and PGA enabled (unless otherwise noted) 0.6 3.3 3.2 GPIO Pin Output Voltage (V) GPIO Pin Output Voltage (V) -40qC 3.1 3 2.9 2.8 -40qC 25qC 85qC 25qC 0.5 0.4 0.3 0.2 0.1 0 0 1 2 3 4 5 Sourcing Current (mA) 6 7 0 8 1 2 AVDD = 3.3 V 0.6 3.2 0.5 Digital Pin Output Voltage (V) -40qC 3.1 3 2.9 2.8 25qC 6 7 8 Figure 32. GPIO Pin Output Voltage vs Sinking Current 3.3 -40qC 3 4 5 Sinking Current (mA) AVDD = 3.3 V Figure 31. GPIO Pin Output Voltage vs Sourcing Current Digital Pin Output Voltage (V) 125qC 125qC 2.7 85qC 25qC 85qC 125qC 0.4 0.3 0.2 0.1 125qC 0 2.7 0 1 2 3 4 5 Sourcing Current (mA) 6 7 0 8 1 2 3 4 5 Sinking Current (mA) 6 7 8 DVDD = 3.3 V DVDD = 3.3 V Figure 33. Digital Pin Output Voltage vs Sourcing Current Figure 34. Digital Pin Output Voltage vs Sinking Current 400 400 Standby mode PGA bypassed Gain = 1 350 Gain = 4 Gain = 16 Gain = 64 Gain = 128 350 300 AVDD Current (PA) AVDD Current (PA) 85qC 250 200 150 200 150 50 50 0 25 50 Temperature (qC) 75 100 125 Standby and conversion mode, external VREF Figure 35. Analog Supply Current vs Temperature Gain = 64 Gain = 128 250 100 -25 Gain = 4 Gain = 16 300 100 0 -50 PGA bypassed Gain = 1 0 2.7 3 3.3 3.6 3.9 4.2 AVDD (V) 4.5 4.8 5.1 5.4 Conversion mode, external VREF Figure 36. Analog Supply Current vs AVDD Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 17 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Typical Characteristics (continued) at TA = 25°C, AVDD = 3.3 V, AVSS = 0 V, DVDD = IOVDD = 3.3 V, using internal VREF = 2.5 V, internal 4.096-MHz oscillator, and PGA enabled (unless otherwise noted) 1 Internal Reference AVDD Current (PA) 260 AVDD Current (PA) 0.8 0.6 0.4 0.2 0 -50 -25 0 25 50 Temperature (qC) 75 100 240 220 200 180 160 140 120 -50 125 -25 0 25 50 Temperature (qC) 75 100 125 Power-down mode Figure 38. Internal Reference AVDD Current vs Temperature 260 240 240 220 220 DVDD Current (PA) DVDD Current (PA) Figure 37. Analog Supply Current vs Temperature 260 200 180 160 140 -25 0 25 50 Temperature (qC) 75 100 180 160 140 Standby mode Conversion mode 120 -50 200 125 120 2.7 2.8 2.9 Standby and conversion mode 3 3.1 3.2 DVDD (V) 3.3 3.4 3.5 3.6 Conversion mode Figure 39. Digital Supply Current vs Temperature Figure 40. Digital Supply Current vs DVDD 5 DVDD Current (PA) 4 3 2 1 0 -50 -25 0 25 50 Temperature (qC) 75 100 125 Power-down mode Figure 41. Digital Supply Current vs Temperature 18 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 8 Parameter Measurement Information 8.1 Noise Performance Delta-sigma (ΔΣ) analog-to-digital converters (ADCs) are based on the principle of oversampling. The input signal of a ΔΣ ADC is sampled at a high frequency (modulator frequency) and subsequently filtered and decimated in the digital domain to yield a conversion result at the respective output data rate. The ratio between modulator frequency and output data rate is called the oversampling ratio (OSR). By increasing the OSR, and thus reducing the output data rate, the noise performance of the ADC can be optimized. In other words, the input-referred noise drops when reducing the output data rate because more samples of the internal modulator are averaged to yield one conversion result. Increasing the gain also reduces the input-referred noise, which is particularly useful when measuring low-level signals. Table 1 and Table 2 summarize the device noise performance. Data are representative of typical noise performance at TA = 25°C using the internal 2.5-V reference. Data shown are based on 512 consecutive samples from a single device with inputs internally shorted. Table 1 lists the input-referred root mean square noise in units of μVRMS for the conditions shown. Peak-to-peak (µVPP) values are shown in parentheses. Table 2 lists the corresponding data in effective resolution calculated from μVRMS values using Equation 1. Noise-free resolution is calculated from µVPP values using Equation 2. The input-referred noise (Table 1) only changes marginally when using an external low-noise reference, such as the REF5025. To calculate effective resolution and noise-free resolution when using a reference voltage other than 2.5 V, use Equation 1 and Equation 2: Effective Resolution = ln[(2 · VREF / Gain) / VRMS-Noise] / ln(2) Noise-Free Resolution= ln[(2 · VREF / Gain) / VPP-Noise] / ln(2) (1) (2) Noise performance with the PGA bypassed are identical to the noise performance of the device with gain = 1. Table 1. Noise in μVRMS (μVPP) at AVDD = 3.3 V, AVSS = 0 V, PGA Enabled, and Internal 2.5-V Reference DATA RATE (SPS) GAIN 1 2 4 8 16 32 64 128 2.5 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.2) 0.60 (0.60) 5 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.2) 0.60 (0.60) 10 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.2) 0.60 (0.60) 16.6 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.2) 0.60 (0.60) 20 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.2) 0.60 (0.60) 50 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.2) 0.60 (0.60) 60 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.2) 0.60 (0.90) 100 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.4) 0.60 (1.3) 200 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.4) 1.2 (1.9) 0.60 (1.7) 400 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (2.8) 1.2 (2.9) 0.60 (2.3) 800 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (4.0) 1.2 (3.8) 0.60 (3.2) 1000 76.3 (76.3) 38.1 (38.1) 19.1 (19.1) 9.5 (9.5) 4.8 (4.8) 2.4 (5.1) 1.2 (4.3) 0.60 (3.8) 2000 76.3 (83) 38.1 (80) 19.1 (32) 9.5 (17) 4.8 (11) 2.4 (6.7) 1.2 (6.6) 1.0 (6.5) 4000 103 (629) 38.1 (404) 24 (160) 12 (70) 6.4 (39) 3.3 (21) 3.1 (21) 2.6 (20) Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 19 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Table 2. Effective Resolution From RMS Noise (Noise-Free Resolution From Peak-to-Peak Noise) at AVDD = 3.3 V, AVSS = 0 V, PGA Enabled, and Internal 2.5-V Reference 20 DATA RATE (SPS) GAIN 1 2 4 8 16 32 64 128 2.5 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 5 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 10 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16.6 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 20 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 50 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.5) 60 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.4) 100 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.8) 16 (14.9) 200 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.3) 16 (14.5) 400 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.8) 16 (14.7) 16 (14.0) 800 16 (16) 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.2) 16 (14.3) 16 (13.6) 1000 16 (16) 16 (16) 16 (16) 16 (16) 16 (15.8) 16 (14.9) 16 (14.2) 16 (13.3) 2000 16 (15.9) 16 (14.9) 16 (15.3) 16 (15.2) 16 (14.8) 16 (14.5) 16 (13.5) 15.2 (12.6) 4000 16 (13.0) 16 (12.6) 15.7 (12.9) 16 (13.1) 15.6 (13.0) 15.5 (12.9) 14.4 (11.9) 13.6 (10.9) Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9 Detailed Description 9.1 Overview The ADS114S06B and ADS114S08B are precision 16-bit, delta-sigma (ΔΣ) ADCs with an integrated analog front end (AFE) to simplify precision sensor connections. The ADC provides output data rates from 2.5 SPS to 4000 SPS for flexibility in resolution and data rates over a wide range of applications. The low-noise and low-drift architecture make these devices suitable for precise measurement of low-voltage sensors, such as load cells and temperature sensors. The ADS114S0xB incorporate several features that simplify precision sensor measurements. Key integrated features include: • Low-noise, CMOS PGA • Low-drift, 2.5-V voltage reference • Two sets of buffered external reference inputs • Dual, matched, sensor-excitation current sources (IDACs) • Internal 4.096-MHz oscillator • Temperature sensor • Four general-purpose input/output pins (GPIOs) As described in the Functional Block Diagram section, these devices provide 12 (ADS114S08B) or six (ADS114S06B) analog inputs that are configurable as either single-ended inputs, differential inputs, or any combination of the two. Many of the analog inputs have additional features as programmed by the user. The analog inputs can be programmed to enable the following extended features: • Two sensor excitation current sources: all analog input pins (and REFP1 and REFN1 on the ADS114S06B) • Sensor biasing voltage (VBIAS): pins AIN0, AIN1, AIN2, AIN3, AIN4, AIN5, AINCOM • Four GPIO pins: AIN8, AIN9, AIN10, AIN11 (ADS114S08B only, the ADS114S06B has dedicated GPIOs) • Sensor burn-out current sources: analog input pins selected for ADC input Following the input multiplexer (MUX), the ADC features a high input-impedance, low-noise, programmable gain amplifier (PGA), eliminating the need for an external amplifier. The PGA gain is programmable from 1 to 128 in binary steps. The PGA can be bypassed to allow the input range to extend 50 mV below ground or above supply. An inherently stable delta-sigma modulator measures the ratio of the input voltage to the reference voltage to provide the ADC result. The ADC operates with the internal 2.5-V reference, or with up to two external reference inputs. The REFOUT pin provides the buffered 2.5-V internal voltage reference output that can be used to bias external circuitry. The digital filter provides settled data with 50-Hz and 60-Hz line-cycle rejection at data rates of 2.5 SPS, 5 SPS, 10 SPS, and 20 SPS, 50-Hz rejection at data rates of 16.6 SPS and 50 SPS, and 60-Hz rejection at a data rate of 60 SPS. Two programmable excitation current sources provide bias to resistive sensors [such as resistance temperature detectors (RTDs) or thermistors]. The ADC integrates several system monitors for read back, such as temperature sensor and supply monitors. Four GPIO pins are available as either dedicated pins (ADS114S06B) or combined with analog input pins (ADS114S08B). The ADS114S0xB system clock is either provided by the internal low-drift, 4.096-MHz oscillator or an external clock source on the CLK input. The SPI-compatible serial interface is used to read the conversion data and also to configure and control the ADC. The serial interface consists of four signals: CS, SCLK, DIN, and DOUT/DRDY. The dual function DOUT/DRDY output indicates when conversion data are ready and also provides the data output. The serial interface can be implemented with as little as three connections by tying CS low. Start ADC conversions with either the START/SYNC pin or with commands. The ADC can be programmed for a continuous conversion mode or to perform single-shot conversions. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 21 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Overview (continued) The AVDD analog supply operates with bipolar supplies from ±1.5 V to ±2.625 V or with a unipolar supply from 2.7 V to 5.25 V. For unipolar-supply operation, use the VBIAS voltage to bias isolated (floating) sensors. The digital supplies operate with unipolar supplies only. The DVDD digital power supply operates from 2.7 V to 3.6 V and the IOVDD supply operates from DVDD to 5.25 V. 9.2 Functional Block Diagram AVDD REFN0 Burnout Detect Excitation Current Sources AINCOM AIN0 REFP0 Reference Mux REFCOM REFOUT DVDD 2.5-V Reference ADS114S06B ADS114S08B IOVDD AIN1 AIN2 Reference Buffers VBIAS AIN3 AIN4 AIN5 Input Mux PGA AIN6 / REFP1 16-Bit û ADC START/SYNC Configurable Digital Filter Serial Interface and Control AIN7 / REFN1 SCLK DIN AIN8 / GPIO0 DOUT/DRDY AIN9 / GPIO1 Power Supplies AIN10 / GPIO2 System-, SelfCalibration Temperature Sensor AIN11 / GPIO3 ADS114S08B Only RESET CS DRDY 4.096-MHz Oscillator Burnout Detect AVSS CLK DGND Copyright © 2017, Texas Instruments Incorporated 22 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.3 Feature Description 9.3.1 Multiplexer The ADS114S0xB contains a flexible input multiplexer; see Figure 42. Select any of the six (ADS114S06B) or 12 (ADS114S08B) analog inputs as the positive or negative input for the PGA using the MUX_P[3:0] and MUX_N[3:0] bits in the input multiplexer register (02h). In addition, AINCOM can be selected as the positive or negative PGA input. AINCOM is treated as a regular analog input, as is AINx. Use AINCOM in single-ended measurement applications as the common input for the other analog inputs. The multiplexer also routes the excitation current sources to drive resistive sensors (bridges, RTDs, and thermistors) and can provide bias voltages for unbiased sensors (unbiased thermocouples for example) to analog input pins. The ADS114S0xB also contain a set of system monitor functions measured through the multiplexer. The inputs can be shorted together at mid-supply [(AVDD + AVSS) / 2] to measure and calibrate the input offset of the analog front-end and the ADC. The system monitor also includes a temperature sensor that provides a measurement of the device temperature. The system monitor can also measure the analog and digital supplies, measuring [(AVDD – AVSS) / 4] for the analog supply or DVDD / 4 for the digital supply. Finally, the system monitor contains a set of burn-out current sources that pull the inputs to either supply if the sensor has burned out and has a high impedance so that the ADC measures a full-scale reading. The multiplexer implements a break-before-make circuit. When changing the multiplexer channels using the MUX_P[3:0] and MUX_N[3:0] bits, the device first disconnects the PGA inputs from the analog inputs and connects them to mid-supply for 2 · tCLK. In the next step, the PGA inputs connect to the selected new analog input channels. This break-before-make behavior ensures the ADC always starts from a known state and that the analog inputs are not momentarily shorted together. Electrostatic discharge (ESD) diodes to AVDD and AVSS protect the inputs. To prevent the ESD diodes from turning on, the absolute voltage on any input must stay within the range provided by Equation 3: AVSS – 0.3 V < V(AINx) < AVDD + 0.3 V (3) External Schottky clamp diodes or series resistors may be required to limit the input current to safe values (see the Absolute Maximum Ratings table). Overdriving an unselected input on the device can affect conversions taking place on other input pins. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 23 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Feature Description (continued) AVDD AVDD IDAC2 IDAC1 (1) AVSS AVDD VBIAS (AVDD + AVSS) / 2 AINCOM VBIAS AVSS AVDD AVSS AVDD AVSS AVDD AVSS AVDD AVSS AVDD AIN0 VBIAS AIN1 VBIAS AVDD AVDD AIN2 VBIAS AIN3 VBIAS Temperature Diode AIN4 (2) VBIAS AVSS AVDD (AVDD í AVSS) ‡ (5 / 8) (AVDD í AVSS) ‡ (3 / 8) AIN5 (3) AVSS AVDD '9'' ‡ (4 / 12) '9'' ‡ (1 / 12) AIN6 AVSS AVDD AVDD AIN7 AVSS AVDD AVSS AVDD Burn-Out Current Source AIN8 AINP PGA To ADC AINN AIN9 AVSS AVDD Burn-Out Current Source AIN10 AVSS AVSS AVDD AIN11 ADS114S08B Only Copyright © 2017, Texas Instruments Incorporated (1) AINP and AINN are connected together to (AVDD + AVSS) / 2 for offset measurement. (2) Measurement for the analog supply equivalent to (AVDD – AVSS) / 4. (3) Measurement for the analog supply equivalent to DVDD / 4. Figure 42. Analog Input Multiplexer 24 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Feature Description (continued) 9.3.2 Low-Noise Programmable Gain Amplifier The ADS114S06B and ADS114S08B feature a low-drift, low-noise, high input impedance programmable gain amplifier (PGA). Figure 43 shows a simplified diagram of the PGA. The PGA consists of two chopper-stabilized amplifiers (A1 and A2) and a resistor feedback network that sets the gain of the PGA. The PGA input is equipped with an electromagnetic interference (EMI) filter and an antialiasing filter on the output. 250 + AINP A1 16 pF RF 320 pF RG RF 250 2.5 k ADC 2.5 k A2 + AINN 16 pF Figure 43. Simplified PGA Diagram The PGA can be set to gains of 1, 2, 4, 8, 16, 32, 64, or 128 using the GAIN[2:0] bits in the gain setting register (03h). Gain is changed inside the device using a variable resistor, RG. The differential full-scale input voltage range (FSR) of the PGA is defined by the gain setting and the reference voltage used, as shown in Equation 4: FSR = ±VREF / Gain (4) Table 3 shows the corresponding full-scale ranges when using the internal 2.5-V reference. Table 3. PGA Full-Scale Range GAIN SETTING FSR 1 ±2.5 V 2 ±1.25 V 4 ±0.625 V 8 ±0.313 V 16 ±0.156 V 32 ±0.078 V 64 ±0.039 V 128 ±0.020 V The PGA must be enabled with the PGA_EN[1:0] bits of the gain setting register (03h). Setting these bits to 00 powers down and bypasses the PGA. A setting of 01 enables the PGA. The 10 and 11 settings are reserved and must not be written to the device. With the PGA enabled, gains 64 and 128 are established in the digital domain. When the device is set to 64 or 128, the PGA is set to a gain of 32, and additional gain is established with digital scaling. The input-referred noise does still improve compared to the gain = 32 setting because the PGA is biased with a higher supply current to reduce noise. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 25 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.3.2.1 PGA Input-Voltage Requirements As with many amplifiers, the PGA has an absolute input voltage range requirement that cannot be exceeded. The maximum and minimum absolute input voltages are limited by the voltage swing capability of the PGA output. The specified minimum and maximum absolute input voltages (VAINP and VAINN) depend on the PGA gain, the maximum differential input voltage (VINMAX), and the tolerance of the analog power-supply voltages (AVDD and AVSS). Use the maximum voltage expected in the application for VINMAX. The absolute positive and negative input voltages must be within the specified range, as shown in Equation 5: AVSS + 0.15 V + |VINMAX| · (Gain – 1) / 2 < VAINP, VAINN < AVDD – 0.15 V – |VINMAX| · (Gain – 1) / 2 where • • VAINP, VAINN = absolute input voltage VINMAX = VAINP – VAINN = maximum differential input voltage (5) As mentioned in the previous section, PGA gain settings of 64 and 128 are scaled in the digital domain and are not implemented with the amplifier. When using the PGA in gains of 64 and 128, set the gain in Equation 5 to 32 to calculate the absolute input voltage range. The relationship between the PGA input to the PGA output is shown graphically in Figure 44. The PGA output voltages (VOUTP, VOUTN) depend on the PGA gain and the input voltage magnitudes. For linear operation, the PGA output voltages must not exceed AVDD – 0.15 V or AVSS + 0.15 V. Note that the diagram depicts a positive differential input voltage that results in a positive differential output voltage. PGA Input PGA Output AVDD AVDD ± 0.15 V VOUTP = VAINP + VIN Â (Gain ± 1) / 2 VAINP VIN = VAINP ± VAINN VAINN VOUTN = VAINN ± VIN Â (Gain ± 1) / 2 AVSS + 0.15 V AVSS Figure 44. PGA Input/Output Range Download the ADS1x4S0x design calculator from www.ti.com. This calculator can be used to determine the input voltage range of the PGA. 9.3.2.2 Bypassing the PGA At a gain of 1, the device can be configured to disable and bypass the low-noise PGA. Disabling the PGA lowers the overall power consumption and also removes the restrictions of Equation 5 for the input voltage range. If the PGA is bypassed, the ADC absolute input voltage range extends beyond the AVDD and AVSS power supplies, allowing input voltages at or below ground. The absolute input voltage range when the PGA is bypassed is shown in Equation 6: AVSS – 0.05 V < VAINP, VAINN < AVDD + 0.05 V (6) In order to measure single-ended signals that are referenced to AVSS (AINP = VIN, AINN = AVSS), the PGA must be bypassed. The PGA is bypassed and powered down by setting the PGA_EN[1:0] bits to 00 in the gain setting register (03h). For signal sources with high output impedance, external buffering may still be necessary. Note that active buffers introduce noise and also introduce offset and gain errors. Consider all of these factors in high-accuracy applications. 26 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.3.3 Voltage Reference The devices require a reference voltage for operation. The ADS114S0xB offers an integrated low-drift 2.5-V reference. For applications that require a different reference voltage value or a ratiometric measurement approach, the ADS114S08B offers two differential reference input pairs (REFP0, REFN0 and REFP1, REFN1). The differential reference inputs allow freedom in the reference common-mode voltage. REFP0 and REFN0 are dedicated reference inputs, whereas REFP1 and REFN1 are shared with inputs AIN6 and AIN7 (respectively) on the ADS114S08B. The specified external reference voltage range is 0.5 V to AVDD. The reference voltage is shown in Equation 7, where V(REFPx) and V(REFNx) are the absolute positive and absolute negative reference voltages. VREF = V(REFPx) – V(REFNx) (7) The polarity of the reference voltage internal to the ADC must be positive. The magnitude of the reference voltage together with the PGA gain establishes the ADC full-scale differential input range as defined by FSR = ±VREF / Gain. Figure 45 shows the block diagram of the reference multiplexer. The ADC reference multiplexer selects between the internal reference and two external references (REF0 and REF1). The reference multiplexer is programmed with the REFSEL[1:0] bits in the reference control register (05h). By default, the external reference pair REFP0, REFN0 is selected. REFSEL[1:0] bits of REF register 00 = REFP0, REFN0 01 = REFP1, REFN1 10 = Internal 2.5-V reference 11 = Reserved REFP_BUF bit of REF register 0 = Enabled 1 = Disabled 00 REFP0 01 REFP1 10 REFOUT VREFP Internal 2.5-V Reference VREFN 1 PF (1) 00 REFN0 01 REFN1 10 REFCOM REFCON[1:0] bits of REF register 00 = Internal reference off 01 = Internal reference on; off in power-down mode 10 = Internal reference always on 11 = Reserved (1) ADC REFN_BUF bit of REF register 0 = Enabled 1 = Disabled The internal reference requires a minimum 1-µF capacitor connected from REFOUT to REFCOM. Figure 45. Reference Multiplexer Block Diagram Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 27 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.3.3.1 Internal Reference The ADC integrates a precision, low-drift, 2.5-V reference. The internal reference is enabled by setting REFCON[1:0] to 10 (reference is always on) or 01 (reference is on, but powers down in power-down mode) in the reference control register (05h). By default, the internal voltage reference is powered down. To select the internal reference for use with the ADC, set the REFSEL[1:0] bits to 10. The REFOUT pin provides a buffered reference output voltage when the internal reference voltage is enabled. The negative reference output is the REFCOM pin, as shown in Figure 45. Connect a capacitor in the range of 1 μF to 47 μF between REFOUT and REFCOM. Larger capacitor values help filter more noise at the expense of a longer reference start-up time. The capacitor is not required if the internal reference is not used. However, the internal reference must be powered on if using the IDACs. The internal reference requires a start-up time that must be accounted for before starting a conversion, as shown in Table 4. Table 4. Internal Reference Settling Time REFOUT CAPACITOR 1 µF 10 µF 47 µF SETTLING ERROR SETTLING TIME (ms) 0.01% 4.5 0.001% 5.9 0.01% 4.9 0.001% 6.3 0.01% 5.5 0.001% 7.0 9.3.3.2 External Reference The ADS114S0xB provides two external reference inputs selectable through the reference multiplexer. The reference inputs are differential with independent positive and negative inputs. REFP0 and REFN0 or REFP1 and REFN1 can be selected as the ADC reference. REFP1 and REFN1 are shared inputs with analog pins AIN6 and AIN7 in the ADS114S08B. Without buffering, the reference input impedance is approximately 250 kΩ. The reference input current can lead to possible errors from either high reference source impedance or through reference input filtering. To reduce the input current, use either internal or external reference buffers. In most applications external reference buffering is not necessary. Connect a bypass capacitor across the external reference input pins if an external reference is used. Follow the specified absolute and differential reference voltage requirements. 9.3.3.3 Reference Buffers The device has two individually selectable reference input buffers to lower the reference input current. Use the REFP_BUF and REFN_BUF bits in the reference control register (05h) to enable or disable the positive and negative reference buffers respectively. These bits are active low. Writing a 1 to REFP_BUF or REFN_BUF disables the reference buffers. The reference buffers are recommended to be disabled when the internal reference is selected for measurements. The positive reference buffer is recommended to be disabled when REFPx is at AVDD and the negative reference buffer is recommended to be disabled when REFNx is at AVSS. 28 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.3.4 Clock Source The ADS114S0xB system clock is either provided by the internal low-drift 4.096-MHz oscillator or an external clock source on the CLK input. Use the CLK bit within the data rate register (04h) to select the internal 4.096-MHz oscillator or an external clock source. The device defaults to using the internal oscillator. If the device is reset (from either the RESET pin, or the RESET command), then the clock source returns to using the internal oscillator. 9.3.5 Delta-Sigma Modulator A delta-sigma (ΔΣ) modulator is used in the devices to convert the analog input voltage into a pulse code modulated (PCM) data stream. The modulator runs at a modulator clock frequency of fMOD = fCLK / 16, where fCLK is either provided by the internal 4.096-MHz oscillator or the external clock source. 9.3.6 Digital Filter The devices offer digital filter options for decimation of the digital data stream coming from the delta-sigma modulator. The implementation of the digital filter is determined by the data rate setting. Figure 46 shows the digital filter implementation. The low-latency digital filter is a finite impulse response (FIR) filter that provides settled data, given that the analog input signal has settled to the final value before the conversion is started. This digital filter implementation is especially useful when multiple channels must be scanned in minimal time. fCLK = 4.096 MHz fCLK / 16 Low-Latency Filter fMOD = 256 kHz SINC3 Filter LL2 Filter LL1 Filter SINC1 Filter SINC1 Filter 20, 10, 5, 2.5 SPS ADC 400, 200, 100, 60, 50, 16.6 SPS ADC data output 4000, 2000, 1000, 800 SPS DR[3:0] bits of DATARATE Register 0000 = 2.5 SPS 1000 = 200 SPS 0001 = 5 SPS 1001 = 400 SPS 0010 = 10 SPS 1010 = 800 SPS 0011 = 16.6 SPS 1011 = 1000 SPS 0100 = 20 SPS 1100 = 2000 SPS 0101 = 50 SPS 1101 = 4000 SPS 0110 = 60 SPS 1110 = 4000 SPS 0111 = 100 SPS 1111 = Reserved NOTE: LL filter = low-latency filter. Figure 46. Digital Filter Architecture Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 29 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com The device requires a set number of modulator clocks to output a single ADC conversion data. This number is known as the oversampling ratio (OSR). The OSR of the digital filter is set using the DR[3:0] bits in the data rate register. The data rate is determined by Equation 8. Data Rate = fMOD / OSR (8) The relationship between the data rate and oversampling ratio is shown in Table 5. Table 5. ADC Data Rates and Digital Filter Oversampling Ratios (1) (2) NOMINAL DATA RATE (SPS) (1) DATA RATE REGISTER DR[3:0] OVERSAMPLING RATIO (2) 2.5 0000 102400 5 0001 51200 10 0010 25600 16.6 0011 15360 20 0100 12800 50 0101 5120 60 0110 4264 100 0111 2560 200 1000 1280 400 1001 640 800 1010 320 1000 1011 256 2000 1100 128 4000 1101 64 Valid for the internal oscillator or an external 4.096-MHz clock. The data rate scales with internal oscillator or external clock frequency. The oversampling ratio is fMOD divided by the data rate; fMOD = fCLK / 16. 9.3.6.1 Digital Filter Frequency Response The digital filter provides many data rate options for rejecting 50-Hz and 60-Hz line cycle noise. At data rates of 2.5 SPS, 5 SPS, 10 SPS, and 20 SPS, the filter rejects both 50-Hz and 60-Hz line frequencies. At data rates of 16.6 SPS and 50 SPS, the filter has a notch at 50 Hz. At a 60-SPS data rate, the filter has a notch at 60 Hz. For detailed frequency response plots showing line cycle noise rejection, download the ADS1x4S0x design calculator from www.ti.com. 30 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 0 0 -20 -20 Magnitude (dB) Magnitude (dB) Figure 47 to Figure 61 illustrate the frequency response of the digital filter for different data rates. Table 6 lists the bandwidth of the digital filter for each data rate. -40 -60 -80 -40 -60 -80 -100 -100 -120 -120 0 10 20 30 40 Frequency (Hz) 50 60 0 70 10 20 fCLK = 4.096 MHz 30 40 Frequency (Hz) 50 60 70 fCLK = 4.096 MHz Figure 47. Digital Filter Frequency Response, Data Rate = 2.5 SPS Figure 48. Digital Filter Frequency Response, Data Rate = 5 SPS 0 0 -40 Magnitude (dB) Magnitude (dB) -20 -60 -80 -20 -40 -100 -60 -120 0 10 20 30 40 50 60 Frequency (Hz) 70 80 90 0 100 20 40 fCLK = 4.096 MHz 120 140 160 fCLK = 4.096 MHz Figure 49. Digital Filter Frequency Response, Data Rate = 10 SPS Figure 50. Digital Filter Frequency Response, Data Rate = 16.6 SPS 0 0 -20 -20 -40 -40 Magnitude (dB) Magnitude (dB) 60 80 100 Frequency (Hz) -60 -80 -100 -60 -80 -100 -120 0 20 40 60 80 100 120 Frequency (Hz) 140 160 180 200 -120 40 45 fCLK = 4.096 MHz 50 55 60 Frequency (Hz) 65 70 fCLK = 4.096 MHz Figure 51. Digital Filter Frequency Response, Data Rate = 20 SPS Figure 52. Digital Filter Frequency Response, Data Rate = 20 SPS, Zoomed to 50 Hz and 60 Hz Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 31 ADS114S06B, ADS114S08B www.ti.com 0 0 -20 -20 Magnitude (dB) Magnitude (dB) SBAS852 – AUGUST 2017 -40 -60 -40 -60 0 50 100 150 200 250 Frequency (Hz) 300 350 400 0 100 fCLK = 4.096 MHz 0 Magnitude (dB) Magnitude (dB) 400 Figure 54. Digital Filter Frequency Response, Data Rate = 60 SPS 0 -20 -40 -20 -40 -60 -60 0 200 400 600 Frequency (Hz) 800 0 1000 400 800 1200 Frequency (Hz) 1600 2000 fCLK = 4.096 MHz fCLK = 4.096 MHz Figure 56. Digital Filter Frequency Response, Data Rate = 200 SPS Figure 55. Digital Filter Frequency Response, Data Rate = 100 SPS 0 0 -20 -20 Magnitude (dB) Magnitude (dB) 300 fCLK = 4.096 MHz Figure 53. Digital Filter Frequency Response, Data Rate = 50 SPS -40 -60 -40 -60 -80 -80 0 500 1000 1500 2000 2500 Frequency (Hz) 3000 3500 4000 0 1000 2000 fCLK = 4.096 MHz 3000 4000 5000 Frequency (Hz) 6000 7000 8000 fCLK = 4.096 MHz Figure 57. Digital Filter Frequency Response, Data Rate = 400 SPS 32 200 Frequency (Hz) Figure 58. Digital Filter Frequency Response, Data Rate = 800 SPS Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 0 0 -20 Magnitude (dB) Magnitude (dB) -20 -40 -60 -40 -60 -80 -100 -80 0 2000 4000 6000 Frequency (Hz) 8000 10000 0 4000 8000 12000 Frequency (Hz) 16000 20000 fCLK = 4.096 MHz fCLK = 4.096 MHz Figure 60. Digital Filter Frequency Response, Data Rate = 2 kSPS Figure 59. Digital Filter Frequency Response, Data Rate = 1 kSPS 0 Magnitude (dB) -20 -40 -60 -80 -100 0 8000 16000 24000 Frequency (Hz) 32000 40000 fCLK = 4.096 MHz Figure 61. Digital Filter Frequency Response, Data Rate = 4 kSPS Table 6. Digital Filter Bandwidth (1) NOMINAL DATA RATE (SPS) (1) –3-dB BANDWIDTH (Hz) (1) 2.5 1.1 5 2.2 10 4.7 16.6 7.4 20 13.2 50 22.1 60 26.6 100 44.4 200 89.9 400 190 800 574 1000 717 2000 1434 4000 2868 Valid for the internal oscillator or an external 4.096-MHz clock. Scales proportional with fCLK. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 33 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com The digital filter notches and output data rate scale proportionally with the clock frequency. For example, a notch that appears at 20 Hz when using a 4.096-MHz clock appears at 10 Hz if a 2.048-MHz clock is used. The internal oscillator can vary over temperature as specified in the Electrical Characteristics table. The data rate, conversion time, and filter notches consequently vary by the same percentage. Consider using an external precision clock source if a digital filter notch at a specific frequency with a tighter tolerance is required. 9.3.6.2 Data Conversion Time The amount of time required to receive data from the ADC depends on more than just the nominal data rate of the device. The data period also depends on the mode of operation and other configurations of the device. In normal operation, the data settles in one data period. However, a small amount of latency exists to set up the device, calculate the conversion data from the modulator samples, and other overhead that adds time to the conversion. For this reason, the first conversion data takes longer than subsequent data conversions. Table 7 shows the conversion times for the digital filter for each ADC data rate and various conversion modes. Table 7. Data Conversion Time NOMINAL DATA RATE (1) (SPS) (1) (2) FIRST DATA FOR CONTINUOUS CONVERSION MODE OR SINGLE-SHOT CONVERSION MODE (2) SECOND AND SUBSEQUENT CONVERSIONS FOR CONTINUOUS CONVERSION MODE ms NUMBER OF tMOD PERIODS ms NUMBER OF tMOD PERIODS 2.5 406.559 104079 400 102400 5 206.559 52879 200 51200 10 106.559 27279 100 25600 16.6 60.309 15439 60 15360 20 56.559 14479 50 12800 50 20.211 5174 20 5120 60 16.965 4343 16.66 4264 100 10.211 2614 10 2560 200 5.211 1334 5 1280 400 2.711 694 2.5 640 800 1.461 374 1.25 320 1000 1.211 310 1 256 2000 0.711 182 0.5 128 4000 0.461 118 0.25 64 Valid for the internal oscillator or an external 4.096-MHz clock. Scales proportional with fCLK. Conversions start at the rising edge of the START/SYNC pin or on the seventh SCLK falling edge for a START command. 9.3.6.3 Note on Conversion Time Each data period consists of time required for the modulator to sample the analog inputs. However, there is additional time required before the samples become an ADC conversion result. When a new conversion is started, there is a configuration delay time of 14 · tMOD (where tMOD = 16 · tCLK) that is added before the conversion starts. This delay allows for additional settling time for external RC filters on the analog inputs and for the antialiasing filter after the PGA. The configuration delay occurs at the start of a new conversion after a START command is sent, the START/SYNC pin is taken high, or a WREG command is sent to change any configuration register from address 03h to 07h (as described in the WREG section). Also, overhead time is needed to convert the modulator samples into an ADC conversion result. This overhead time includes any necessary offset or gain compensation after the digital filter accumulates a data result. The first conversion when the device is in continuous conversion mode (just as in single-shot conversion mode) includes the configuration delay, the modulator sampling time, and the overhead time. The second and subsequent conversions are the normal data period (period as given by the inverse of the data rate). 34 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Figure 62 shows the time sequence for the ADC in both continuous conversion and single-shot conversion modes. Single-shot conversion mode Conversion start(1) Data ready Configuration delay Modulator sampling x x Sampling for first data ADC overhead x DRDY Continuous conversion mode Conversion start(1) x First data ready Second data ready Third data ready Sampling for first data Sampling for second data x Continued sampling Sampling for third data DRDY (1) Conversions start at the rising edge of the START/SYNC pin or on the seventh SCLK falling edge for a START command. Figure 62. Single-Shot Conversion Mode and Continuous Conversion Mode Sequences 9.3.6.4 50-Hz and 60-Hz Line Cycle Rejection If the ADC connection leads are in close proximity to industrial motors and conductors, coupling of 50-Hz and 60-Hz power line frequencies can occur. The coupled noise interferes with the signal voltage, and can lead to inaccurate or unstable conversions. The digital filter provides enhanced rejection of power-line-coupled noise for data rates of 60 SPS and less. Program the filter to tradeoff data rate and conversion latency versus the desired level of line cycle rejection. Table 8 summarizes the ADC 50-Hz and 60-Hz line-cycle rejection based on ±1-Hz and ±2-Hz tolerance of power-line frequency. The best possible power-line rejection is provided by using an accurate ADC clock. Table 8. 50-Hz and 60-Hz Line Cycle Rejection DATA RATE (SPS) (1) (1) DIGITAL FILTER LINE CYCLE REJECTION (dB) 50 Hz ± 1 Hz 60 Hz ± 1 Hz 50 Hz ± 2 Hz 60 Hz ± 2 Hz 2.5 –113.7 –95.4 –97.7 –92.4 5 –111.9 –95.4 –87.6 –81.8 10 –111.5 –95.4 –85.7 –81.0 16.6 –33.8 –20.9 –27.8 –20.8 20 –95.4 –95.4 –75.5 –80.5 50 –33.8 –15.5 –27.6 –15.1 60 –13.4 –35.0 –12.6 –29.0 fCLK = 4.096 MHz. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 35 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.3.7 Excitation Current Sources (IDACs) The ADS114S0xB incorporates two integrated, matched current sources (IDAC1, IDAC2). The current sources provide excitation current to resistive temperature devices (RTDs), thermistors, diodes, and other resistive sensors that require constant current biasing. The current sources are programmable to output values between 10 μA to 2000 μA using the IMAG[3:0] bits in the excitation current register 1 (06h). Each current source can be connected to any of the analog inputs AINx as well as the REFP1 and REFN1 inputs for the ADS114S06B. Both current sources can also be connected to the same pin. The routing of the IDACs is configured by the I1MUX[3:0] and I2MUX[3:0] bits in the excitation current register 2 (07h). In three-wire RTD applications, the matched current sources can be used to cancel errors caused by sensor lead resistance (see the Typical Application section for more details). Figure 63 details the IDAC connection through the input multiplexer. I1MUX[3:0] bits of the IDACMUX register. IDAC routing to AIN8 ± AIN11 is available only on the ADS114S08B. AIN0 AIN0 0000 AIN1 AIN1 0001 AIN2 AIN2 0010 AIN3 AIN3 0011 AIN4 AIN4 0100 AIN5 0101 AIN6 / REFP1 AIN6/REFP1 0110 AIN7 / REFN1 AIN7/REFN1 0111 1000 AIN5 AIN8 AIN8 ADS114S08B AIN9 Only AIN10 AIN9 1001 AIN10 1010 AIN11 AIN11 1011 AINCOM 1100 AINCOM AVDD IDAC1 Mux IDAC1 IMAG[3:0] bits of the IDACMAG register. 0000 = Off 0001 = 10 µA 0010 = 50 µA 0011 = 100 µA 0100 = 250 µA 0101 = 500 µA 0110 = 750 µA 0111 = 1000 µA 1000 = 1500 µA 1001 = 2000 µA No Connection 1101-1111 AIN0 0000 AIN1 0001 AIN2 0010 AIN3 0011 AIN4 0100 AIN5 0101 AIN6/REFP1 0110 AIN7/REFN1 0111 AIN8 1000 AIN9 1001 AIN10 1010 AIN11 1011 AINCOM 1100 AVDD IDAC2 Mux IDAC2 No Connection 1101-1111 I2MUX[3:0] bits of the IDACMUX register. IDAC routing to AIN8 ± AIN11 is available only on the ADS114S08B. Copyright © 2017, Texas Instruments Incorporated Figure 63. IDAC Block Diagram The internal reference must be enabled for IDAC operation. As any current source, the IDAC requires voltage headroom to the positive supply to operate. This voltage headroom is the compliance voltage. When driving resistive sensors and biasing resistors, take care not to exceed the compliance voltage of the IDACs, otherwise the specified accuracy of the IDAC current may not be met. For IDAC compliance voltage specifications, see the Electrical Characteristics table. 36 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.3.8 Bias Voltage Generation The ADS114S0xB provides an internal bias voltage generator, VBIAS, that is set to (AVDD + AVSS) / 2. The bias voltage is internally buffered and can be established on the analog inputs AIN0 to AIN5 and AINCOM using the VB_AINx bits in the sensor biasing register (08h). A typical use case for VBIAS is biasing unbiased thermocouples to within the common-mode voltage range of the PGA. A block diagram of the VBIAS voltage generator and connection diagram is shown in Figure 64. AVDD AIN0 AIN1 AIN2 Input Mux AIN3 AIN4 AIN5 R AINCOM (AVDD + AVSS) / 2 VB_AINx bits of VBIAS register 0 = VBIAS not connected to AINx 1 = VBIAS connected to AINx R AVSS Figure 64. VBIAS Block Diagram The start-up time of the VBIAS voltage depends on the pin load capacitance. The total capacitance includes any capacitance connected from VBIAS to AVDD, AVSS, and ground. Table 9 lists the VBIAS voltage settling times for various external load capacitances. Ensure the VBIAS voltage is fully settled before starting a conversion. Table 9. VBIAS Settling Time LOAD CAPACITANCE SETTLING TIME 0.1 µF 280 µs 1 µF 2.8 ms 10 µF 28 ms Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 37 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.3.9 System Monitor The ADS114S0xB provides a set of system monitor functions. These functions measure the device temperature, analog power supply, digital power supply, or use current sources to detect sensor malfunction. System monitor functions are enabled through the SYS_MON[2:0] bits of the system control register (09h). 9.3.9.1 Internal Temperature Sensor On-chip diodes provide temperature-sensing capability. Enable the internal temperature sensor by setting SYS_MON[2:0] = 010 in the system control register (09h). The temperature sensor outputs a voltage proportional to the device temperature as specified in the Electrical Characteristics table. When measuring the internal temperature sensor, the analog inputs are disconnected from the ADC and the output voltage of the temperature sensor is routed to the ADC for measurement using the selected PGA gain, data rate, and voltage reference. If enabled, PGA gain must be limited to 4 for the temperature sensor measurement to remain within the allowed absolute input voltage range of the PGA. As a result of the low device junction-to-PCB thermal resistance (RθJB), the internal device temperature closely tracks the printed circuit board (PCB) temperature. 9.3.9.2 Power Supply Monitors The ADS114S0xB provides a means for monitoring both the analog and digital power supply (AVDD and DVDD). The power-supply voltages are divided by a resistor network to reduce the voltages to within the ADC input range. The reduced power-supply voltage is routed to the ADC input multiplexer. The analog (VANLMON) and digital (VDIGMON) power-supply readings are scaled by Equation 9 and Equation 10, respectively: VANLMON = (AVDD – AVSS) / 4 VDIGMON = (DVDD – DGND) / 4 (9) (10) Enable the supply voltage monitors using the SYS_MON[2:0] bits in the system control register (09h). Setting SYS_MON[2:0] to 011 measures VANLMON, and setting SYS_MON[2:0] to 100 measures VDIGMON. When the supply voltage monitor is enabled, the analog inputs are disconnected from the ADC and the PGA gain is set to 1, regardless of the GAIN[2:0] bit values in the gain setting register (03h). Supply voltage monitor measurements can be done with either the PGA enabled or PGA disabled via the PGA_EN[1:0] register. To obtain valid power-supply monitor readings, the reference voltage must be larger than the power-supply measurements shown in Equation 9 and Equation 10. 9.3.9.3 Burn-Out Current Sources To help detect a possible sensor malfunction, the ADS114S0xB provides selectable current sources to function as burn-out current sources (BOCS) using the SYS_MON[2:0] bits in the system control register (09h). Current sources are set to values of 0.2 µA, 1 µA, and 10 µA with SYS_MON[2:0] settings of 101, 110, and 111, respectively. When enabled, one BOCS sources current to the selected positive analog input (AINP) and the other BOCS sinks current from the selected negative analog input (AINN). With an open-circuit in a burned out sensor, these BOCSs pull the positive input towards AVDD and the negative input towards AVSS, resulting in a full-scale reading. A full-scale reading can also indicate that the sensor is overloaded or that the reference voltage is absent. A near-zero reading can indicate a shorted sensor. Distinguishing a shorted sensor condition from a normal reading can be difficult, especially if an RC filter is used at the inputs. The voltage drop across the external filter resistance and the residual resistance of the multiplexer can cause the output to read a value higher than zero. The ADC readings of a functional sensor can be corrupted when the burn-out current sources are enabled. The burn-out current sources are recommended to be disabled when performing the precision measurement, and are recommended to be enabled only when testing for sensor fault conditions. If the global chop mode is enabled, disable this mode before making a measurement with the burn-out current sources. 38 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.3.10 Status Register The ADS114S0xB has a one-byte status register (01h) that contains a POR flag to indicate if a start-up or poweron reset condition has occurred and a RDY flag to indicate when a device has started up and is ready for communication. The status register data field and field description are found in Figure 77 and Table 17. 9.3.10.1 POR Flag After the power supplies are turned on, the ADC remains in reset until DVDD, IOVDD, and the analog power supply (AVDD – AVSS) voltage exceed the respective power-on reset (POR) voltage thresholds. If a POR event has occurred, the FL_POR flag (bit 7 of the status register) is set. This flag indicates that a POR event has occurred and has not been cleared. This flag is cleared with a user register write to set the bit to 0. The power-on reset is described further in the Power-On Reset section. 9.3.10.2 RDY Flag The RDY flag indicates that the device has started up and is ready to receive a configuration change. During a reset or POR event, the device is resetting the register map and may not be available. The RDY flag is shown with bit 6 of the status register. 9.3.11 General-Purpose Inputs and Outputs (GPIOs) The ADS114S06B offers four dedicated general-purpose input and output (GPIO) pins, and the ADS114S08B offers four pins (AIN8 to AIN11) that serve a dual purpose as either analog inputs or GPIOs. Two registers control the function of the GPIO pins. Use the CON[3:0] bits of the GPIO configuration register (11h) to configure a pin as a GPIO pin. The upper four bits (DIR[3:0]) of the GPIO data register (10h) configure the GPIO pin as either an input or an output. The lower four bits (DAT[3:0]) of the GPIO data register contain the input or output GPIO data. If a GPIO pin is configured as an input, the respective DAT[x] bit reads the status of the pin; if a GPIO pin is configured as an output, write the output status to the respective DAT[x] bit. For more information about the use of GPIO pins, see the Configuration Registers section. Figure 65 depicts a diagram of how these functions are combined onto a single pin. Note that when the pin is configured as a GPIO, the corresponding logic is powered from AVDD and AVSS. When the devices are operated with bipolar analog supplies, the GPIO outputs bipolar voltages. Care must be taken to not load the GPIO pins when used as outputs because large currents can cause droop or noise on the analog supplies. GPIO pins use Schmitt triggered inputs with hysteresis to make the input more resistance to noise; see the Electrical Characteristics table for GPIO thresholds. For connections of unused GPIO pins, see the Unused Inputs and Outputs section. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 39 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com AVDD CON[3:0] bits of GPIOCON register 0 = no connect 1 = connect DAT[3:0] bits of GPIODAT register 0 = VGPIO is low 1 = VGPIO is high GPIO 1 of 4 AIN8 AIN9 Write GPIO[0] 0 GPIO[1] Read 0 1 GPIO[2] AIN10 GPIO Read Select GPIO[3] AIN11 DIR[7:4] bits of GPIODAT register 0 = Output 1 = Input GPIO logic is powered from AVDD to AVSS AVSS Figure 65. GPIO Block Diagram 9.3.12 Calibration The ADC incorporates offset and gain calibration commands, as well as user-offset and full-scale (gain) calibration registers to calibrate the ADC. The ADC calibration registers are 16 bits wide. Use calibration to correct internal ADC errors or overall system errors. Calibrate by sending calibration commands to the ADC, or by direct user calibration. In user calibration, the user calculates and writes the correction values to the calibration registers. The ADC performs self or system-offset calibration, or a system gain calibration. Perform offset calibration before system gain calibration. After power-on, wait for the power supplies and reference voltage to fully settle before calibrating. As shown in Figure 66, the value of the offset calibration register is subtracted from the filter output and then multiplied by the full-scale register value divided by 4000h. The data are then clipped to a 16-bit value to provide the final output. AINN Digital Filter ADC AINP ADC + Output Data Clipped to 16 bits Final Output 1/4000h OFCAL[1:0] registers (register addresses = 0Ch, 0Bh) > 0000h: negative offset = 0000h: no offset < 0000h: positive offset FSCAL[1:0] registers (register addresses = 0Fh, 0Eh) < 4000h: Gain > 1 = 4000h: Gain = 1 > 4000h: Gain < 1 Figure 66. ADC Calibration Block Diagram Calibration commands cannot be used when the device is in standby mode (when the START/SYNC pin is low, or when the STOP command is issued). 40 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.3.12.1 Offset Calibration The offset calibration word is 16 bits, consisting of two 8-bit registers, as shown in the two registers starting with offset calibration register 1. The offset value is twos complement format with a maximum positive value equal to 7FFFh, and a maximum negative value equal to 8000h. This value is subtracted from each output reading as an offset correction. A register value equal to 0000h has no offset correction. If global chop mode is enabled, the offset calibration register is disabled. Table 10 shows example settings of the offset register. Table 10. Offset Calibration Register Values (1) OFC REGISTER VALUE OFFSET CALIBRATED OUTPUT CODE (1) 0001h FFFFh 0000h 0000h FFFFh 0001h Ideal output code with shorted input, excluding ADC noise and offset voltage error. The user can select how many samples (1, 4, 8, or 16) to average for self or system offset calibration using the CAL_SAMP[1:0] bits in the system control register (09h). Fewer readings shorten the calibration time but also provide less accuracy. Averaging more readings takes longer but yields a more accurate calibration result by reducing the noise level. Two commands can be used to perform offset calibration. SFOCAL is a self offset calibration that internally sets the input to mid-scale using the SYS_MON[2:0] = 001 setting and takes a measurement of the offset. SYOCAL is a system offset calibration where the user must input a null voltage to calibrate the system offset. After either command is issued, the OFC register is updated. After an offset calibration is performed, the device starts a new conversion and DRDY falls to indicate a new conversion has completed. 9.3.12.2 Gain Calibration The full-scale (gain) calibration word is 16 bits consisting of two 8-bit registers, as shown in the two registers starting with gain calibration register 1. The gain calibration value is straight binary, normalized to a unity-gain correction factor at a register value equal to 4000h. Table 11 shows register values for selected gain factors. Do not exceed the PGA input range limits during gain calibration. Table 11. Gain Calibration Register Values FSC REGISTER VALUE GAIN FACTOR 4333h 1.05 4000h 1.00 3CCCh 0.95 All gains of the ADS114S0xB are factory trimmed to meet the gain error specified in the Electrical Characteristics table at TA = 25°C. When the gain drift of the devices over temperature is very low, there is typically no need for self gain calibration. The SYGCAL command initiates a system gain calibration, where the user sets the input to full-scale to remove gain error. After the SYGCAL is issued, the FSC register is updated. As with the offset calibration, the CAL_SAMP[1:0] bits determine the number of samples used for a gain calibration. As with an offset calibration, the device starts a new conversion after a gain calibration and DRDY falls to indicate a new conversion has completed. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 41 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.4 Device Functional Modes The device operates in three different modes: power-down mode, standby mode, and conversion mode. Figure 67 shows a flow chart of the different operating modes and how the device transitions from one mode to another. Power-On Reset or RESET pin high or RESET command?(1) Power-down Mode(2) Reset device to default settings WAKEUP Command? No Yes Standby Mode No Complete current conversion(4) START/SYNC rising edge or START Command? Yes Yes Conversion Mode No START/SYNC pin low or STOP Command? Start new conversion 1 = Single-Shot conversion mode Conversion mode selection(3) 0 = Continuous conversion mode (1) Any reset (power-on, command, or pin), immediately resets the device. (2) A POWERDOWN command aborts an ongoing conversion and immediately puts the device into power-down mode. (3) The conversion mode is selected with the MODE bit in the data rate register. (4) The rising edge of the START/SYNC pin or the START command starts a new conversion without completing the current conversion. Figure 67. Operating Flow Chart 9.4.1 Reset The ADS114S0xB is reset in one of three ways: • Power-on reset • RESET pin • RESET command When a reset occurs, the configuration registers reset to default values and the device enters standby mode. The device then waits for the rising edge of the START/SYNC pin or a START command to enter conversion mode. If the device had been using an external clock, the reset sets the device to use the internal oscillator as a default configuration. See the Timing Characteristics section for reset timing information. 42 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Device Functional Modes (continued) 9.4.1.1 Power-On Reset The ADS114S0xB incorporates a power-on reset circuit that holds the device in reset until all supplies reach approximately 1.65 V. The power-on reset also ensures that the device starts operating in a known state in case a brown-out event occurs, when the supplies have dipped below the minimum operating voltages. When the device completes a POR sequence, the FL_POR flag in the status register is set high to indicate that a POR has occurred. Begin communications with the device 2.2 ms after the power supplies reach minimum operating voltages. The only exception is polling the status register for the RDY bit. If the user polls the RDY bit, then use an SCLK rate of half the maximum-specified SCLK rate to get a proper reading when the device is making internal configurations. This 2.2-ms POR time is required for the internal oscillator to start up and the device to properly set internal configurations. After the internal configurations are set, the device sets the RDY bit in the device status register (01h). When this bit is set to 0, user configurations can be programmed into the device. Figure 68 shows the power-on reset timing sequence for the device. DVDD, IOVDD VPOR VPOR All supplies reach minimum operating voltage AVDD - AVSS Internal Oscillator Startup FL_POR bit of STATUS register is set to 1 Internal Configuration Standby Mode RDY bit of STATUS register is set to 0 2.2 ms If polling for RDY during this period, SCLK must be less than half maximum rate Figure 68. Power-On Reset Timing Sequence 9.4.1.2 RESET Pin Reset the ADC by taking the RESET pin low for a minimum of 4 · tCLK· cycles, and then returning the pin high. After the rising edge of the RESET pin, a delay time of td(RSSC) is required before sending the first serial interface command or starting a conversion. See the Timing Characteristics section for reset timing information. 9.4.1.3 Reset by Command Reset the ADC by using the RESET command (06h or 07h). The command is decoded on the seventh SCLK falling edge. After sending the RESET command, a delay time of td(RSSC) is required before sending the first serial interface command or starting a conversion. See the Timing Characteristics section for reset timing information. 9.4.2 Power-Down Mode Power-down mode is entered by sending the POWERDOWN command. In this mode, all analog and digital circuitry is powered down for lowest power consumption regardless of the register settings. Only the internal voltage reference can be configured to stay on during power-down mode in case a faster start-up time is required. All register values retain the current settings during power-down mode. The configuration registers can be read and written in power-down mode. A WAKEUP command must be issued in order to exit power-down mode and to enter standby mode. When the POWERDOWN command is issued, the device enters power-down mode 2 · tCLK after the seventh SCLK falling edge of the command. For lowest power consumption (on DVDD and IOVDD), stop the external clock when in power-down mode. TI recommends selecting the internal oscillator before sending the POWERDOWN command to avoid issues with the command decoding. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 43 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Device Functional Modes (continued) To release the device from POWERDOWN, issue the WAKEUP command to enter standby mode. The device then waits for the rising edge of the START/SYNC pin or a START command to go into conversion mode. When in power-down mode, the device responds to the RREG, RDATA, and WAKEUP commands. The WREG and RESET commands can also be sent, but are ignored until a WAKEUP command is sent and the internal oscillator resumes operation. 9.4.3 Standby Mode The device powers up in standby mode and automatically enters this mode whenever there is no ongoing conversion. When the STOP command is sent (or the START/SYNC pin is taken low) in continuous conversion mode, or when a conversion completes in single-shot conversion mode, the device enters standby mode. Standby mode offers several different options and features to lower the power consumption: • The PGA can be powered down by setting PGA_EN[1:0] to 00 in the gain setting register (03h). • The internal voltage reference can be powered down by setting REFCON[1:0] to 00 in the reference control register (05h). This setting also turns off the IDACs. • The digital filter is held in reset state. • The clock to the modulator and digital core is gated to decrease dynamic switching losses. If powered down in standby mode, the PGA and internal reference can require extra time to power up. Extra delay may be required between power up of the PGA or the internal reference, and the start of conversions. In particular, the reference power up time is dependent on the capacitance between REFOUT and REFCOM. Calibration commands are not decoded when the device is in standby mode. 9.4.4 Conversion Modes The ADS114S0xB offers two conversion modes: continuous conversion and single-shot conversion mode. Continuous-conversion mode converts indefinitely until stopped by the user. Single-shot conversion mode performs one conversion after the START/SYNC pin is taken high or after the START command is sent. Use the MODE bit in the data rate register (04h) to program the conversion mode. Figure 69 shows how the START/SYNC pin and the START command are used to control ADC conversions. (2) (1) (2) DRDY START/SYNC Pin SCLK START Command DIN START (3) Standby Mode STOP Conversion Mode Standby Mode (1) DRDY rises at the first SCLK rising edge or the rising edge of the START/SYNC pin. (2) START and STOP commands take effect 2 · tCLK after the seventh SCLK falling edge. The conversion starts 2 · tCLK after the START/SYNC rising edge. (3) To synchronize a conversion, the STOP command must be issued prior to the START command. STOP and START commands can be issued without a delay between the commands. Figure 69. Conversion Start and Stop Timing 44 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Device Functional Modes (continued) ADC conversions are controlled by the START/SYNC pin or by serial commands. For the device to start converting in continuous conversion or single-shot conversion mode, a START command must be sent or the START/SYNC pin must be taken high. If using commands to control conversions, keep the START/SYNC pin low to avoid possible contentions between the START/SYNC pin and commands. Conversions can be synchronized to perform a conversion at a particular time. To synchronize the conversion with the START/SYNC pin, take the pin low. The rising edge of the START/SYNC pin starts a new conversion. Similarly, a conversion can be synchronized using the START command. If the device is in standby mode, issue a START command. If the device is in conversion mode, issue a STOP command followed by a START command. The STOP and START commands can be consecutive. A new conversion starts on the seventh SCLK falling edge of the START command. 9.4.4.1 Continuous Conversion Mode The device is configured for continuous conversion mode by setting the MODE bit to 0 in the data rate register (04h). A START command must be sent or the START/SYNC pin must be taken high for the device to start converting continuously. When controlling the device with commands, hold the START/SYNC pin low. Taking the START/SYNC pin low or sending the STOP command stops the device from converting after the currently ongoing conversion completes, indicated by the falling edge of DRDY. The device enters standby mode thereafter. For information on the exact timing of continuous conversion mode data, see Table 7. 9.4.4.2 Single-Shot Conversion Mode The device is configured for single-shot conversion mode by setting the MODE bit to 1 in the data rate register (04h). A START command must be sent or the START/SYNC pin must be taken high for the device to start a single conversion. After the conversion completes, the device enters standby mode again. To start a new conversion, the START command must be sent again or the START/SYNC pin must be taken low and then high again. For information on the exact timing of single-shot conversion mode data, see Table 7. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 45 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.5 Programming 9.5.1 Serial Interface The ADC has an SPI-compatible, bidirectional serial interface that is used to read the conversion data as well as to configure and control the ADC. Only SPI mode 1 (CPOL = 0, CPHA = 1) is supported. The serial interface consists of five control lines: CS, SCLK, DIN, DOUT/DRDY, and DRDY but can be used with only four or even three control signals. If the ADS114S08B or ADS114S06B is the only device connected to the SPI bus, then the CS input can be tied low so that only SCLK, DIN, and DOUT/DRDY are required to communicate with the device. 9.5.1.1 Chip Select (CS) The CS pin is an active low input that enables the ADC serial interface for communication and is useful when multiple devices share the same serial bus. CS must be low during the entire data transaction. When CS is high, the serial interface is reset, SCLK input activity is ignored (blocking input commands), and the DOUT/DRDY output enters a high-impedance state. ADC conversions are not affected by the state of CS. In situations where multiple devices are present on the bus, the dedicated DRDY pin can provide an uninterrupted monitor of the conversion status and is not affected by CS. If the serial bus is not shared with another peripheral, CS can be tied to DGND to permanently enable the ADC interface and DOUT/DRDY can be used to indicate conversion status. These changes reduce the serial interface from five I/Os to three I/Os. 9.5.1.2 Serial Clock (SCLK) The serial interface clock is a noise-filtered, Schmidt-triggered input used to clock data into and out of the ADC. Input data to the ADC are latched on the falling SCLK edge and output data from the ADC are updated on the rising SCLK edge. Return SCLK low after the data sequence is complete. Even though the SCLK input has hysteresis, keep SCLK as clean as possible to prevent unintentional SCLK transitions. Avoid ringing and voltage overshoot on the SCLK input. Place a series termination resistor at the SCLK drive pin to help reduce ringing. 9.5.1.3 Serial Data Input (DIN) The serial data input pin (DIN) is used with SCLK to send data (commands and register data) to the device. The device latches data on DIN on the SCLK falling edge. The device never drives the DIN pin. During data readback, when no command is intended, keep DIN low. 9.5.1.4 Serial Data Output and Data Ready (DOUT/DRDY) The DOUT/DRDY pin is a dual-function output. The pin functions as the digital data output and the ADC dataready indication. First, this pin is used with SCLK to read conversion and register data from the device. Conversion or register data are shifted out on DOUT/DRDY on the SCLK rising edge. DOUT/DRDY goes to a high-impedance state when CS is high. Second, the DOUT/DRDY pin indicates availability of new conversion data. DOUT/DRDY transitions low at the same time that the DRDY pin goes low to indicate new conversion data are available. Both signals can be used to detect if new data are ready. However, because DOUT/DRDY is disabled when CS is high, use the dedicated DRDY pin when monitoring conversions on multiple devices on the SPI bus. 46 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Programming (continued) 9.5.1.5 Data Ready (DRDY) The DRDY pin is an output that transitions low to indicate when conversion data are ready for retrieval. Initially, DRDY is high at power-on. When converting, the state of DRDY depends on whether the conversion data are retrieved or not. In continuous conversion mode after DRDY goes low, DRDY is driven high on the first SCLK rising edge. If data are not read, DRDY remains low and then pulses high 24 · tCLK before the next DRDY falling edge. The data must be retrieved before the next DRDY update, otherwise the data are overwritten by new data and any previous data are lost. Figure 70 shows the DRDY operation without data retrieval. Figure 71 shows the DRDY operation with data retrieval after each conversion completes. DRDY START/SYNC Pin SCLK START Command DIN (1) START DRDY returns high with the rising edge of the first SCLK after a data ready indication. Figure 70. DRDY Operation Without Data Retrieval DRDY START/SYNC SCLK START Command DIN START (3) DOUT/DRDY RDATA RDATA 'RQ¶W Care 'RQ¶W Care Conversion Data 1 (1) Conversion Data 2 DRDY returns high with the rising edge of the first SCLK after a data ready indication. Figure 71. DRDY Operation With Data Retrieval 9.5.1.6 Timeout The ADS114S0xB offers a serial interface timeout feature that is used to recover communication when a serial interface transmission is interrupted. This feature is especially useful in applications where CS is permanently tied low and is not used to frame a communication sequence. The SPI interface resets when no valid 8 bits are received within 215 · tCLK. The timeout feature is enabled by setting the TIMEOUT bit to 1 in the system control register (09h). Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 47 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Programming (continued) 9.5.2 Data Format The devices provide 16 bits of data in binary twos complement format. The size of one code (LSB) is calculated using Equation 11. 1 LSB = (2 · VREF / Gain) / 216 = +FS / 215 (11) A positive full-scale input [VIN ≥ (+FS – 1 LSB) = (VREF / Gain – 1 LSB)] produces an output code of 7FFFh and a negative full-scale input (VIN ≤ –FS = –VREF / Gain) produces an output code of 8000h. The output clips at these codes for signals that exceed full-scale. Table 12 summarizes the ideal output codes for different input signals. Table 12. Ideal Output Code vs Input Signal INPUT SIGNAL, VIN = VAINP – VAINN 15 ≥ FS (2 IDEAL OUTPUT CODE (1) 15 – 1) / 2 7FFFh FS / 215 0001h 0 0000h 15 (1) –FS / 2 FFFFh ≤ –FS 8000h Excludes the effects of noise, INL, offset, and gain errors. Mapping of the analog input signal to the output codes is shown in Figure 72. 7FFFh 0001h 0000h FFFFh ¼ Output Code ¼ 7FFEh 8001h 8000h ¼ -FS 2 15 FS ¼ -1 -FS 2 0 Input Voltage (VIN) 15 2 15 FS 2 -1 15 Figure 72. Code Transition Diagram 48 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.5.3 Commands Commands are used to control the ADC, access the configuration registers, and retrieve data. Many of the commands are stand-alone (that is, single-byte). The register write and register read commands, however, are multibyte, consisting of two command bytes plus the register data byte or bytes. The commands are listed in Table 13. Table 13. Command Definitions COMMAND DESCRIPTION FIRST COMMAND BYTE SECOND COMMAND BYTE Control Commands NOP No operation 0000 0000 (00h) — WAKEUP Wake-up from power-down mode 0000 001x (02h, 03h) (1) — POWERDOWN Enter power-down mode 0000 010x (04h, 05h) (1) — (1) — RESET Reset the device 0000 011x (06h, 07h) START Start conversions 0000 100x (08h, 09h) (1) — STOP Stop conversions 0000 101x (0Ah, 0Bh) (1) — Calibration Commands SYOCAL System offset calibration 0001 0110 (16h) — SYGCAL System gain calibration 0001 0111 (17h) — SFOCAL Self offset calibration 0001 1001 (19h) — 0001 001x (12h / 13h) (1) — Read nnnnn registers starting at address rrrrr 001r rrrr (2) 000n nnnn (3) Write nnnnn registers starting at address rrrrr (2) 000n nnnn (3) Data Read Command RDATA Read data Register Read and Write Commands RREG WREG (1) (2) (3) 010r rrrr x = don't care. r rrrr = starting register address. n nnnn = number of registers to read or write – 1. Commands can be sent at any time, either during a conversion or when conversions are stopped. However, if register read or write commands are in progress when conversion data are ready, the ADC blocks loading of conversion data to the output shift register. The CS input pin can be taken high between commands; or held low between consecutive commands. CS must stay low for the entire command sequence. Complete the command, or terminate the command before completion by taking CS high. Only send the commands that are listed in Table 13. 9.5.3.1 NOP NOP is a no-operation command. The NOP command is used to clock out data without clocking in a command. 9.5.3.2 WAKEUP Issue the WAKEUP command to exit power-down mode and to place the device into standby mode. When running off the external clock, the external clock must be running before sending the WAKEUP command, otherwise the command is not decoded. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 49 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.5.3.3 POWERDOWN Sending the POWERDOWN command aborts a currently ongoing conversion and puts the device into powerdown mode. The device goes into power-down mode 2 · tCLK after the seventh SCLK falling edge of the command. For lowest power consumption on DVDD and IOVDD, stop the external clock when in power-down mode. The device does not gate the external clock. When running off the external clock, provide at a minimum two additional tCLKs after the POWERDOWN command is issued, otherwise the device does not enter power-down mode. Alternatively, select the internal oscillator before sending the POWERDOWN command to avoid any issues with decoding of the POWERDOWN and WAKEUP commands. During power-down mode, the only commands that are available are RREG, RDATA, and WAKEUP. 9.5.3.4 RESET The RESET command resets the digital filter and sets all configuration register values to default settings. A RESET command also puts the device into standby mode. When in standby mode, the device waits for a rising edge on the START/SYNC pin or a START command to resume conversions. After sending the RESET command, a delay time of td(RSSC) is required before sending the first serial interface command or starting a conversion. See the Timing Characteristics section for reset timing information. If the device had been using an external clock, the reset sets the device to use the internal oscillator as a default configuration. 9.5.3.5 START When the device is configured for continuous conversion mode, issue the START command for the device to start converting. Every time a conversion completes, the device automatically starts a new conversion until the STOP command is sent. In single-shot conversion mode, the START command is used to start a single conversion. After the conversion completes, the device enters standby mode. Tie the START/SYNC pin low when the device is controlled through the START and STOP commands. The START command is not decoded if the START/SYNC pin is high. If the device is already in conversion mode, the START command has no effect. 9.5.3.6 STOP The STOP command is used in continuous conversion mode to stop the device from converting. The current conversion is allowed to complete. After DRDY transitions low, the device enters standby mode. The STOP command has no effect in single-shot conversion mode. Hold the START/SYNC pin low when the device is controlled through START and STOP commands. 9.5.3.7 SYOCAL The SYOCAL command initiates a system offset calibration. For a system offset calibration, the inputs must be externally shorted to a voltage within the input range, ideally near the mid-supply voltage of (AVDD + AVSS) / 2. The OFC registers are updated when the command completes. Calibration commands must be issued in conversion mode. 9.5.3.8 SYGCAL The SYGCAL command initiates the system gain calibration. For a system gain calibration, the input must be externally set to full-scale. The FSC registers are updated after this operation. Calibration commands must be issued in conversion mode. 9.5.3.9 SFOCAL The SFOCAL command initiates a self offset calibration. The device internally shorts the inputs to mid-supply and performs the calibration. The OFC registers are updated after this operation. Calibration commands must be issued in conversion mode. 50 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.5.3.10 RDATA Read conversion data from the device with the RDATA command at any time. Figure 73 shows the read data sequence. The MSB of the conversion data is output on the first SCLK rising edge after the command. An RDATA command must be sent for each read operation. The ADC does not respond to commands until the read operation is complete, or terminated by taking CS high. New data indicated by the DRDY and DOUT/DRDY will not corrupt a read of conversion data with RDATA. After all bytes are read, the data-byte sequence is repeated by continuing SCLK. CS (1) 9 1 17 SCLK DIN DOUT/DRDY RDATA HI-Z (2) 'RQ¶W &DUH Data 1 Data 2 ADC Data Bytes (1) CS can be tied low. If CS is low, DOUT/DRDY asserts low with DRDY. (2) DOUT/DRDY is driven low with DRDY. If a read operation occurs after the DRDY falling edge, then DOUT/DRDY can be high or low. Figure 73. Read Data Sequence 9.5.3.11 RREG Use the RREG command to read the device register data. Read the register data one register at a time, or read a block of register data. The starting register address can be any register in the register map. The RREG command consists of two bytes. The first byte specifies the starting register address: 001r rrrr, where r rrrr is the starting register address. The second command byte is the number of registers to read (minus 1): 000n nnnn, where n nnnn is the number of registers to read minus 1. After the read command is sent, the ADC responds with one or more register data bytes, most significant bit first. If the byte count exceeds the last register address, the ADC begins to output zero data. During the register read operation, any conversion data that becomes available is not loaded to the output shift register to avoid data contention. However, the conversion data can be retrieved later by the RDATA command. After the register read command has started, further commands are blocked until one of the following conditions are met: • The read operation is completed • The read operation is terminated by taking CS high • The read operation is terminated by a serial interface timeout • The ADC is reset by toggling the RESET pin Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 51 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Figure 74 shows a two-register read operation example. As shown, the commands required to read data from two registers starting at register REF (address = 05h) are: command byte 1 = 25h and command byte 2 = 01h. Keep DIN low after the two command bytes are sent. (1) CS 1 9 17 25 SCLK '21¶7 &$5( DOUT/DRDY DIN (1) '21¶7 &$5( 0010 0101 REG DATA 1 REG DATA 2 0000 0001 CS can be set high or kept low between commands. If kept low, the command must be completed. Figure 74. Read Register Sequence 9.5.3.12 WREG Use the WREG command to write the device register data. The register data are written one register at a time or as a block of register data. The starting register address is any register in the register map. The WREG command consists of two bytes. The first byte specifies the starting register address: 010r rrrr, where r rrrr is the starting register address The second command byte is the number of registers to write (minus 1): 000n nnnn, where n nnnn is the number of registers to write minus 1. The following byte (or bytes) is the register data, most significant bit first. If the byte count exceeds the last register address, the ADC ignores the data. After the register write command has started, further commands are blocked until one of the following conditions are met: • The write operation is completed • The write operation is terminated by taking CS high • The write operation is terminated by a serial interface timeout • The ADC is reset by toggling the RESET pin Figure 75 shows a two-register write operation example. As shown, the required commands to write data to two registers starting at register REF (address = 05h) are: command byte 1 = 45h and command byte 2 = 01h. (1) CS 1 9 17 25 SCLK DOUT/DRDY '21¶7 &$5( DIN 0100 0101 (1) '21¶7 &$5( 0000 0001 '21¶7 &$5( REG DATA 1 '21¶7 &$5( REG DATA 2 CS can be set high or kept low between commands. If kept low, the command must be completed. Figure 75. Write Register Sequence 52 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Writing new data to certain configuration registers resets the digital filter and starts a new conversion if a conversion is in progress. Writing to the following registers triggers a new conversion: • Channel configuration register (02h) • Gain setting register (03h) • Data rate register (04h) • Reference control register (05h), bits [5:0] • Excitation current register 1 (06h), bits [3:0] • Excitation current register 2 (07h) • System control register (09h), bits [7:5] When the device is configured with WREG, the first data ready indication occurs after the new conversion completes with the configuration settings. The previous conversion data are cleared at restart; therefore read the previous data before the register write operation. Again, a WREG to these registers only starts a new conversion if a conversion is in progress. If the device is in standby mode, the device sets the configuration according to the WREG data, but does not start a conversion until the START/SYNC pin is taken high or a START command is issued. 9.5.4 Interfacing with Multiple Devices When connecting multiple devices to a single SPI bus, SCLK, DIN, and DOUT/DRDY can be safely shared by using a dedicated chip-select (CS) line for each SPI-enabled device. When CS transitions high for the respective device, DOUT/DRDY enters a tri-state mode. Therefore, DOUT/DRDY cannot be used to indicate when new data are available if CS is high. Only the dedicated DRDY pin indicates that new data are available because the DRDY pin is actively driven even when CS is high. In some cases, the DRDY pin cannot be interfaced to the microcontroller. This scenario can occur if there are insufficient GPIO channels available on the microcontroller or if the serial interface must be galvanically isolated and thus the amount of channels must be limited. In order to evaluate when a new conversion of one of the devices is ready, the microcontroller can periodically drop CS to the respective device and poll the state of the DOUT/DRDY pin. When CS goes low, the DOUT/DRDY pin immediately drives either high or low. If the DOUT/DRDY line drives low, new data are available. If the DOUT/DRDY line drives high, no new data are available. This procedure requires that DOUT/DRDY is forced high after reading each conversion result and before taking CS high. To make sure DOUT/DRDY is taken high, send a RREG command to read a register where the least significant bit is 1. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 53 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.6 Register Map 9.6.1 Configuration Registers The ADS114S0xB register map consists of 18, 8-bit registers. These registers are used to configure and control the device to the desired mode of operation. Access the registers through the serial interface by using the RREG and WREG register commands. After power-on or reset, the registers default to the initial settings, as shown in the Default column of Table 14. Data can be written as a block to multiple registers using a single WREG command. If data are written as a block, the data of certain registers take effect immediately when data are shifted in. Writing new data to certain registers results in a restart of conversions that are in progress. The registers that result in a conversion restart are discussed in the WREG section. Table 14. Configuration Register Map ADDR REGISTER DEFAULT 00h ID xxh BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 01h STATUS 80h 02h INPMUX 01h 03h PGA 00h 0 0 0 04h DATARATE 14h 0 CLK MODE 1 05h REF 10h 0 0 REFP_BUF REFN_BUF 06h IDACMAG 00h 0 0 0 0 07h IDACMUX FFh 08h VBIAS 00h 0 VB_AINC VB_AIN5 VB_AIN4 09h SYS 10h 0Ah RESERVED 00h FL_POR RDY 0 BIT 1 BIT 0 DEV_ID[2:0] 0 0 0 MUXP[3:0] 0 0 MUXN[3:0] PGA_EN[1:0] GAIN[2:0] DR[3:0] REFSEL[1:0] REFCON[1:0] IMAG[3:0] I2MUX[3:0] I1MUX[3:0] SYS_MON[2:0] VB_AIN3 CAL_SAMP[1:0] VB_AIN2 VB_AIN1 VB_AIN0 TIMEOUT 0 0 RESERVED 0Bh OFCAL0 00h OFC[7:0] 0Ch OFCAL1 00h OFC[15:8] 0Dh RESERVED 00h RESERVED 0Eh FSCAL0 00h FSC[7:0] 0Fh FSCAL1 40h FSC[15:8] 10h GPIODAT 00h 11h GPIOCON 00h 54 BIT 2 RESERVED DIR[3:0] 0 0 DAT[3:0] 0 0 Submit Documentation Feedback CON[3:0] Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.6.2 Register Descriptions Table 15 lists the access codes for the ADS114S0xB registers. Table 15. ADS114S0xB Access Type Codes Access Type Code Description R R Read R-W R/W Read or Write W W Write -n Value after reset or the default value 9.6.2.1 Device ID Register (address = 00h) [reset = xxh] Figure 76. Device ID (ID) Register 7 6 5 RESERVED R-xxh 4 3 2 1 DEV_ID[2:0] R-xh 0 1 0 R-0h 0 0 R-0h Table 16. Device ID (ID) Register Field Descriptions Bit Field Type Reset Description 7:3 RESERVED R xxh Reserved 2:0 DEV_ID[2:0] R xh Values are subject to change without notice Device identifier. Identifies the model of the device. 000 : Reserved 001 : Reserved 010 : Reserved 011 : Reserved 100 : ADS114S08B (12 channels, 16 bits) 101 : ADS114S06B (6 channels, 16 bits) 110 : Reserved 111 : Reserved 9.6.2.2 Device Status Register (address = 01h) [reset = 80h] Figure 77. Device Status (STATUS) Register 7 FL_POR R/W-1h 6 RDY R-0h 5 0 R-0h 4 0 R-0h 3 0 R-0h 2 0 R-0h Table 17. Device Status (STATUS) Register Field Descriptions Bit 7 Field Type Reset Description FL_POR R/W 1h POR flag. Indicates a power-on reset (POR) event has occurred. 0 : Register has been cleared and no POR event has occurred 1 : POR event occurred and has not been cleared. Flag must be cleared by user register write (default). 6 RDY R 0h Device ready flag. Indicates the device has started up and is ready for communication. 0 : ADC ready for communication (default) 1 : ADC not ready 5:0 RESERVED R 00h Reserved Always write 00h Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 55 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.6.2.3 Input Multiplexer Register (address = 02h) [reset = 01h] Figure 78. Input Multiplexer (INPMUX) Register 7 6 5 4 3 MUXP[3:0] R/W-0h 2 1 0 MUXN[3:0] R/W-1h Table 18. Input Multiplexer (INPMUX) Register Field Descriptions Bit Field Type Reset Description 7:4 MUXP[3:0] R/W 0h Positive ADC input selection. Selects the ADC positive input channel. 0000 : AIN0 (default) 0001 : AIN1 0010 : AIN2 0011 : AIN3 0100 : AIN4 0101 : AIN5 0110 : AIN6 (ADS114S08B only) 0111 : AIN7 (ADS114S08B only) 1000 : AIN8 (ADS114S08B only) 1001 : AIN9 (ADS114S08B only) 1010 : AIN10 (ADS114S08B only) 1011 : AIN11 (ADS114S08B only) 1100 : AINCOM 1101 : Reserved 1110 : Reserved 1111 : Reserved 3:0 MUXN[3:0] R/W 1h Negative ADC input selection. Selects the ADC negative input channel. 0000 : AIN0 0001 : AIN1 (default) 0010 : AIN2 0011 : AIN3 0100 : AIN4 0101 : AIN5 0110 : AIN6 (ADS114S08B only) 0111 : AIN7 (ADS114S08B only) 1000 : AIN8 (ADS114S08B only) 1001 : AIN9 (ADS114S08B only) 1010 : AIN10 (ADS114S08B only) 1011 : AIN11 (ADS114S08B only) 1100 : AINCOM 1101 : Reserved 1110 : Reserved 1111 : Reserved 56 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.6.2.4 Gain Setting Register (address = 03h) [reset = 00h] Figure 79. Gain Setting (PGA) Register 7 0 R/W-0h 6 0 R/W-0h 5 0 R/W-0h 4 3 2 1 GAIN[2:0] R/W-0h PGA_EN[1:0] R/W-0h 0 Table 19. Gain Setting (PGA) Register Field Descriptions Bit Field Type Reset Description 7:5 RESERVED R/W 0h Reserved 4:3 PGA_EN[1:0] R/W 0h Always write 0h PGA enable. Enables or bypasses the PGA. 00 : PGA is powered down and bypassed. Enables single-ended measurements with unipolar supply (Set gain = 1 (1)) (default) 01 : PGA enabled (gain = 1 to 128) 10 : Reserved 11 : Reserved 2:0 GAIN[2:0] R/W 0h PGA gain selection. Configures the PGA gain. 000 : 1 (default) 001 : 2 010 : 4 011 : 8 100 : 16 101 : 32 110 : 64 111 : 128 (1) When bypassing the PGA, the user must also set GAIN[2:0] to 000. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 57 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.6.2.5 Data Rate Register (address = 04h) [reset = 14h] Figure 80. Data Rate (DATARATE) Register 7 0 R/W-0h 6 CLK R/W-0h 5 MODE R/W-0h 4 1 R/W-1h 3 2 1 0 DR[3:0] R/W-4h Table 20. Data Rate (DATARATE) Register Field Descriptions Bit Field Type Reset Description 7 RESERVED R/W 0h Reserved 6 CLK R/W 0h Always write 0h Clock source selection. Configures the clock source to use either the internal oscillator or an external clock. 0 : Internal 4.096-MHz oscillator (default) 1 : External clock 5 MODE R/W 0h Conversion mode selection. Configures the ADC for either continuous conversion or single-shot conversion mode. 0 : Continuous conversion mode (default) 1 : Single-shot conversion mode 4 RESERVED R/W 1h DR[3:0] R/W 4h Reserved Always write 1h 3:0 Data rate selection. Configures the output data rate (1). 0000 : 2.5 SPS 0001 : 5 SPS 0010 : 10 SPS 0011 : 16.6 SPS 0100 : 20 SPS (default) 0101 : 50SPS 0110 : 60 SPS 0111 : 100 SPS 1000 : 200 SPS 1001 : 400 SPS 1010 : 800 SPS 1011 : 1000 SPS 1100 : 2000 SPS 1101 : 4000 SPS 1110 : 4000 SPS 1111 : Reserved (1) 58 Data rates of 60 Hz or less can offer line-cycle rejection; see the 50-Hz and 60-Hz Line Cycle Rejection section for more information. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.6.2.6 Reference Control Register (address = 05h) [reset = 10h] Figure 81. Reference Control (REF) Register 7 0 R/W-0h 6 0 R/W-0h 5 REFP_BUF R/W-0h 4 REFN_BUF R/W-1h 3 2 1 REFSEL[1:0] R/W-0h 0 REFCON[1:0] R/W-0h Table 21. Reference Control (REF) Register Field Descriptions Bit Field Type Reset Description 7:6 RESERVED R/W 0h Reserved 5 REFP_BUF R/W 0h Always write 0h Positive reference buffer bypass. Disables the positive reference buffer. Recommended when V(REFPx) is close to AVDD. 0 : Enabled (default) 1 : Disabled 4 REFN_BUF R/W 1h Negative reference buffer bypass. Disables the negative reference buffer. Recommended when V(REFNx) is close to AVSS. 0 : Enabled 1 : Disabled (default) 3:2 REFSEL[1:0] R/W 0h Reference input selection. Selects the reference input source for the ADC. 00 : REFP0, REFN0 (default) 01 : REFP1, REFN1 10 : Internal 2.5-V reference (1) 11 : Reserved 1:0 REFCON[1:0] R/W 0h Internal voltage reference configuration (2). Configures the behavior of the internal voltage reference. 00 : Internal reference off (default) 01 : Internal reference on, but powers down in power-down mode 10 : Internal reference is always on, even in power-down mode 11 : Reserved (1) (2) Disable the reference buffers when the internal reference is selected for measurements. The internal voltage reference must be turned on to use the IDACs. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 59 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.6.2.7 Excitation Current Register 1 (address = 06h) [reset = 00h] Figure 82. Excitation Current Register 1 (IDACMAG) 7 0 R/W-0h 6 0 R/W-0h 5 0 R/W-0h 4 0 R/W-0h 3 2 1 0 IMAG[3:0] R/W-0h Table 22. Excitation Current Register 1 (IDACMAG) Register Field Descriptions Bit Field Type Reset Description 7:4 RESERVED R/W 0h Reserved 3:0 IMAG[3:0] R/W 0h Always write 0h IDAC magnitude selection. Selects the value of the excitation current sources. Sets IDAC1 and IDAC2 to the same value. 0000 : Off (default) 0001 : 10 µA 0010 : 50 µA 0011 : 100 µA 0100 : 250 µA 0101 : 500 µA 0110 : 750 µA 0111 : 1000 µA 1000 : 1500 µA 1001 : 2000 µA 1010–1111 : Off 60 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.6.2.8 Excitation Current Register 2 (address = 07h) [reset = FFh] Figure 83. Excitation Current Register 2 (IDACMUX) 7 6 5 4 3 2 I2MUX[3:0] R/W-Fh 1 0 I1MUX[3:0] R/W-Fh Table 23. Excitation Current Register 2 (IDACMUX) Register Field Descriptions Bit Field Type Reset Description 7:4 I2MUX[3:0] R/W Fh IDAC2 output channel selection. Selects the output channel for IDAC2. 0000 : AIN0 0001 : AIN1 0010 : AIN2 0011 : AIN3 0100 : AIN4 0101 : AIN5 0110 : AIN6 (ADS114S08B), REFP1 (ADS114S06B) 0111 : AIN7 (ADS114S08B), REFN1 (ADS114S06B) 1000 : AIN8 (ADS114S08B only) 1001 : AIN9 (ADS114S08B only) 1010 : AIN10 (ADS114S08B only) 1011 : AIN11 (ADS114S08B only) 1100 : AINCOM 1101–1111 : Disconnected (default) 3:0 I1MUX[3:0] R/W Fh IDAC1 output channel selection. Selects the output channel for IDAC1. 0000 : AIN0 0001 : AIN1 0010 : AIN2 0011 : AIN3 0100 : AIN4 0101 : AIN5 0110 : AIN6 (ADS114S08B only), REFP1 (ADS114S06B) 0111 : AIN7 (ADS114S08B only), REFN1 (ADS114S06B) 1000 : AIN8 (ADS114S08B only) 1001 : AIN9 (ADS114S08B only) 1010 : AIN10 (ADS114S08B only) 1011 : AIN11 (ADS114S08B only) 1100 : AINCOM 1101–1111 : Disconnected (default) Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 61 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.6.2.9 Sensor Biasing Register (address = 08h) [reset = 00h] Figure 84. Sensor Biasing (VBIAS) Register 7 0 R/W-0h 6 VB_AINC R/W-0h 5 VB_AIN5 R/W-0h 4 VB_AIN4 R/W-0h 3 VB_AIN3 R/W-0h 2 VB_AIN2 R/W-0h 1 VB_AIN1 R/W-0h 0 VB_AIN0 R/W-0h Table 24. Sensor Biasing (VBIAS) Register Field Descriptions Bit Field Type Reset Description 7 RESERVED R/W 0h Reserved 6 VB_AINC R/W 0h Always write 0h AINCOM VBIAS selection (1). Enables VBIAS on the AINCOM pin. 0 : VBIAS disconnected from AINCOM (default) 1 : VBIAS connected to AINCOM 5 VB_AIN5 R/W 0h AIN5 VBIAS selection (1). Enables VBIAS on the AIN5 pin. 0 : VBIAS disconnected from AIN5 (default) 1 : VBIAS connected to AIN5 4 VB_AIN4 R/W 0h AIN4 VBIAS selection (1). Enables VBIAS on the AIN4 pin. 0 : VBIAS disconnected from AIN4 (default) 1 : VBIAS connected to AIN4 3 VB_AIN3 R/W 0h AIN3 VBIAS selection (1). Enables VBIAS on the AIN3 pin. 0 : VBIAS disconnected from AIN3 (default) 1 : VBIAS connected to AIN3 2 VB_AIN2 R/W 0h AIN2 VBIAS selection (1). Enables VBIAS on the AIN2 pin. 0 : VBIAS disconnected from AIN2 (default) 1 : VBIAS connected to AIN2 1 VB_AIN1 R/W 0h AIN1 VBIAS selection (1). Enables VBIAS on the AIN1 pin. 0 : VBIAS disconnected from AIN1 (default) 1 : VBIAS connected to AIN1 0 VB_AIN0 R/W 0h AIN0 VBIAS selection (1). Enables VBIAS on the AIN0 pin. 0 : VBIAS disconnected from AIN0 (default) 1 : VBIAS connected to AIN0 (1) 62 The bias voltage can be selected for multiple analog inputs at the same time. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.6.2.10 System Control Register (address = 09h) [reset = 10h] Figure 85. System Control (SYS) Register 7 6 SYS_MON[2:0] R/W-0h 5 4 3 CAL_SAMP[1:0] R/W-2h 2 TIMEOUT R/W-0h 1 0 R/W-0h 0 0 R/W-0h Table 25. System Control (SYS) Register Field Descriptions Bit Field Type Reset Description 7:5 SYS_MON[2:0] R/W 0h System monitor configuration (1). Enables a set of system monitor measurements using the ADC. 000 : Disabled (default) 001 : PGA inputs shorted to (AVDD + AVSS) / 2 and disconnected from AINx and the multiplexer; gain set by user 010 : Internal temperature sensor measurement; PGA must be enabled (PGA_EN[1:0] = 01); gain set by user (2) 011 : (AVDD – AVSS) / 4 measurement; gain set to 1 (3) 100 : DVDD / 4 measurement; gain set to 1 (3) 101 : Burn-out current sources enabled, 0.2-µA setting 110 : Burn-out current sources enabled, 1-µA setting 111 : Burn-out current sources enabled, 10-µA setting 4:3 CAL_SAMP[1:0] R/W 2h Calibration sample size selection. Configures the number of samples averaged for self and system offset and system gain calibration. 00 : 1 sample 01 : 4 samples 10 : 8 samples (default) 11 : 16 samples 2 TIMEOUT R/W 0h SPI timeout enable. Enables the SPI timeout function. 0 : Disabled (default) 1 : Enabled 1:0 RESERVED R/W 0h Reserved Always write 0h (1) (2) (3) With system monitor functions enabled, the AINx multiplexer switches are open for the (AVDD + AVSS) / 2 measurement, the temperature sensor, and the supply monitors. When using the internal temperature sensor, gain must be 4 or less to keep the measurement within the PGA input voltage range. The PGA gain is automatically set to 1 when the supply monitors are enabled, regardless of the setting in GAIN[2:0]. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 63 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.6.2.11 Reserved Register (address = 0Ah) [reset = 00h] Figure 86. Reserved Register 7 6 5 4 3 2 1 0 1 0 RESERVED R-00h Table 26. Reserved Register Field Descriptions Bit Field Type Reset 7:0 RESERVED R 00h Description Reserved Always write 00h 9.6.2.12 Offset Calibration Register 1 (address = 0Bh) [reset = 00h] Figure 87. Offset Calibration Register 1 (OFCAL0) 7 6 5 4 3 2 OFC[7:0] R/W-00h Table 27. Offset Calibration Register 1 (OFCAL0) Register Field Descriptions Bit Field Type Reset Description 7:0 OFC[7:0] R/W 00h Bits [7:0] of the offset calibration value. 9.6.2.13 Offset Calibration Register 2 (address = 0Ch) [reset = 00h] Figure 88. Offset Calibration Register 2 (OFCAL1) 7 6 5 4 3 2 1 0 OFC[15:8] R/W-00h Table 28. Offset Calibration Register 2 (OFCAL1) Register Field Descriptions 64 Bit Field Type Reset Description 7:0 OFC[15:8] R/W 00h Bits [15:8] of the offset calibration value. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 9.6.2.14 Reserved Register (address = 0Dh) [reset = 00h] Figure 89. Reserved Register 7 6 5 4 3 2 1 0 1 0 RESERVED R-00h Table 29. Reserved Register Field Descriptions Bit Field Type Reset 7:0 RESERVED R 00h Description Reserved Always write 00h 9.6.2.15 Gain Calibration Register 1 (address = 0Eh) [reset = 00h] Figure 90. Gain Calibration Register 1 (FSCAL0) 7 6 5 4 3 2 FSC[7:0] R/W-00h Table 30. Gain Calibration Register 1 (FSCAL0) Field Descriptions Bit Field Type Reset Description 7:0 FSC[7:0] R/W 00h Bits [7:0] of the gain calibration value. 9.6.2.16 Gain Calibration Register 2 (address = 0Fh) [reset = 40h] Figure 91. Gain Calibration Register 2 (FSCAL1) 7 6 5 4 3 2 1 0 FSC[15:8] R/W-40h Table 31. Gain Calibration Register 2 (FSCAL1) Field Descriptions Bit Field Type Reset Description 7:0 FSC[15:8] R/W 40h Bits [15:8] of the gain calibration value. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 65 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 9.6.2.17 GPIO Data Register (address = 10h) [reset = 00h] Figure 92. GPIO Data (GPIODAT) Register 7 6 5 4 3 2 DIR[3:0] R/W-0h 1 0 DAT[3:0] R/W-0h Table 32. GPIO Data (GPIODAT) Register Field Descriptions Bit Field Type Reset Description 7:4 DIR[3:0] R/W 0h GPIO direction. Configures the selected GPIO as an input or output. 0 : GPIO[x] configured as output (default) 1 : GPIO[x] configured as input 3:0 DAT[3:0] R/W 0h GPIO data. Contains the data of the GPIO inputs or outputs. 0 : GPIO[x] is low (default) 1 : GPIO[x] is high 9.6.2.18 GPIO Configuration Register (address = 11h) [reset = 00h] Figure 93. GPIO Configuration Register 7 0 R-0h 6 0 R-0h 5 0 R-0h 4 0 R-0h 3 2 1 0 CON[3:0] R/W-0h Table 33. GPIO Configuration (GPIOCON) Register Field Descriptions Bit Field Type Reset Description 7:4 RESERVED R 0h Reserved 3:0 CON[3:0] R/W 0h Always write 0h GPIO pin configuration. Configures the GPIO[x] pin as an analog input or GPIO. CON[x] corresponds to the GPIO[x] pin. 0 : GPIO[x] configured as analog input (default) (1) 1 : GPIO[x] configured as GPIO (1) 66 On the ADS114S06B, the GPIO pins default as disabled. Set the CON[3:0] bits to enable the respective GPIO pins. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 10 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 10.1 Application Information The ADS114S06B and ADS114S08B are precision, 16-bit, ΔΣ ADCs that offer many integrated features to simplify the measurement of the most common sensor types (including various types of temperature, flow, and bridge sensors). Primary considerations when designing an application with the ADS114S0xB include analog input filtering, establishing an appropriate reference, and setting the absolute input voltage for the internal PGA. Connecting and configuring the serial interface appropriately is another concern. These considerations are discussed in the following sections. 10.1.1 Serial Interface Connections The principle serial interface connections for the ADS114S0xB are shown in Figure 94. 21 20 19 18 CLK GPIO3/AIN11 22 RESET GPIO2/AIN10 23 GPIO1/AIN9 24 GPIO0/AIN8 REFOUT REFCOM 1 PF 17 3.3 V 47 NC 5V 25 DVDD GPIO 16 47 26 AVDD IOVDD 15 GPIO/IRQ 0.1 PF 330 nF 47 27 DGND AVSS 14 MISO 47 28 DRDY AVSS 13 SCLK 47 REFN0 29 DOUT/DRDY 12 REFP0 30 SCLK 11 MOSI Microcontroller with SPI 47 GPIO 47 REFN1/AIN7 REFP1/AIN6 31 DIN 32 CS 10 9 GPIO 3.3 V DVDD 5 AIN5 AIN4 AIN3 AIN2 6 7 8 0.1 PF START/SYNC 4 AIN0 3 AIN1 2 AINCOM DVSS 1 Figure 94. Serial Interface Connections Most microcontroller SPI peripherals can interface with the ADS114S0xB. The interface operates in SPI mode 1 where CPOL = 0 and CPHA = 1. In SPI mode 1, SCLK idles low and data are launched or changed only on SCLK rising edges; data are latched or read by the master and slave on SCLK falling edges. Details of the SPI communication protocol employed by the devices are found in the Serial Interface section. Place 47-Ω resistors in series with all digital input and output pins (CS, SCLK, DIN, DOUT/DRDY, and DRDY). This resistance smooths sharp transitions, suppresses overshoot, and offers some overvoltage protection. Care must be taken to meet all SPI timing requirements because the additional resistors interact with the bus capacitances present on the digital signal lines. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 67 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Application Information (continued) 10.1.2 Analog Input Filtering Analog input filtering serves two purposes: first, to limit the effect of aliasing during the sampling process and second, to reduce external noise from being a part of the measurement. As with any sampled system, aliasing can occur if proper antialias filtering is not in place. Aliasing occurs when frequency components are present in the input signal that are higher than half the sampling frequency of the ADC (also known as the Nyquist frequency). These frequency components are folded back and show up in the actual frequency band of interest below half the sampling frequency. Inside a ΔΣ ADC, the input signal is oversampled at the modulator frequency, fMOD and not at the output data rate. The filter response of the digital filter repeats at multiples of fMOD, as shown in Figure 95. Signals or noise up to a frequency where the filter response repeats are attenuated to a certain amount by the digital filter depending on the filter architecture. Any frequency components present in the input signal around the modulator frequency or multiples thereof are not attenuated and alias back into the band of interest, unless attenuated by an external analog filter. Magnitude Sensor Signal Unwanted Signals Unwanted Signals Output Data Rate fMOD/2 fMOD Frequency fMOD Frequency fMOD Frequency Magnitude Digital Filter Aliasing of Unwanted Signals Output Data Rate fMOD/2 Magnitude External Antialiasing Filter Roll-Off Output Data Rate fMOD/2 Figure 95. Effect of Aliasing 68 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Application Information (continued) Many sensor signals are inherently band limited; for example, the output of a thermocouple has a limited rate of change. In this case, the sensor signal does not alias back into the pass band when using a ΔΣ ADC. However, any noise pick-up along the sensor wiring or the application circuitry can potentially alias into the pass band. Power line-cycle frequency and harmonics are one common noise source. External noise can also be generated from electromagnetic interference (EMI) or radio frequency interference (RFI) sources, such as nearby motors and cellular phones. Another noise source typically exists on the printed circuit board (PCB) itself in the form of clocks and other digital signals. Analog input filtering helps remove unwanted signals from affecting the measurement result. A first-order resistor-capacitor (RC) filter is (in most cases) sufficient to either eliminate aliasing, or to reduce the effect of aliasing to a level below the noise floor of the sensor. Ideally, any signal beyond fMOD / 2 is attenuated to a level below the noise floor of the ADC. The digital filter of the ADS114S0xB attenuates signals to a certain degree, as illustrated in the filter response plots in the Digital Filter section. In addition, noise components are usually smaller in magnitude than the actual sensor signal. Therefore, using a first-order RC filter with a cutoff frequency set at the output data rate or 10 times higher is generally a good starting point for a system design. Internal to the device, prior to the PGA inputs, is an EMI filter; see Figure 43. The cutoff frequency of this filter is approximately 40 MHz and helps reject high-frequency interference. 10.1.3 External Reference and Ratiometric Measurements The full-scale range of the ADS114S0xB is defined by the reference voltage and the PGA gain (FSR = ±VREF / Gain). An external reference can be used instead of the integrated 2.5-V reference to adapt the FSR to the specific system needs. An external reference must be used if VIN > 2.5 V. For example, an external 5-V reference and an AVDD = 5 V are required in order to measure a single-ended signal that can swing between 0 V and 5 V. The reference inputs of the device also allow the implementation of ratiometric measurements. In a ratiometric measurement, the same excitation source that is used to excite the sensor is also used to establish the reference for the ADC. As an example, a simple form of a ratiometric measurement uses the same current source to excite both the resistive sensor element (such as an RTD) and another resistive reference element that is in series with the element being measured. The voltage that develops across the reference element is used as the reference source for the ADC. Because current noise and drift are common to both the sensor measurement and the reference, these components cancel out in the ADC transfer function. The output code is only a ratio of the sensor element and the value of the reference resistor. The value of the excitation current source itself is not part of the ADC transfer function. The example in the Typical Application section describes a system that uses a ratiometric measurement. One excitation current source is used to drive a reference resistor and an RTD. The ADC measurement represents a ratiometric measurement between the RTD value and a known reference resistor value. 10.1.4 Establishing a Proper Input Voltage The ADS114S0xB can be used to measure various types of input signal configurations: single-ended, pseudodifferential, and fully-differential signals (which can be either unipolar or bipolar). However, configuring the device properly for the respective signal type is important. Signals where the negative analog input is fixed and referenced to analog ground (VAINN = 0 V) are commonly called single-ended signals. The input voltage of a single-ended signal consequently varies between 0 V and VIN. If the PGA is disabled and bypassed, the input voltage of the ADS114S0xB can be as low as 50 mV below AVSS and as large as 50 mV above AVDD. Therefore, set the PGA_EN bits to 10 in the gain setting register (03h) to measure single-ended signals when a unipolar analog supply is used (AVSS = 0 V). Only a gain of 1 is possible in this configuration. Measuring a 0-mA to 20-mA or 4-mA to 20-mA signal across a load resistor of 100 Ω referenced to GND is a typical example. The ADS114S0xB can directly measure the signal across the load resistor using a unipolar supply, the internal 2.5-V reference, and gain = 1 when the PGA is bypassed. If gain is needed to measure a single-ended signal, the PGA must be enabled. In this case, a bipolar supply is required for the ADS114S0xB to meet the input voltage requirement of the PGA. Signals where the negative analog input (AINN) is fixed at a voltage other the 0 V are referred to as pseudo-differential signals. The input voltage of a pseudo-differential signal varies between VAINN and VAINN + VIN. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 69 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Application Information (continued) Fully-differential signals in contrast are defined as signals having a constant common-mode voltage where the positive and negative analog inputs swing 180° out-of-phase but have the same amplitude. The ADS114S0xB can measure pseudo-differential and fully-differential signals both with the PGA enabled or bypassed. However, the PGA must be enabled in order to measure any input with a gain greater than 1. The input voltage must meet the input and output voltage restrictions of the PGA, as explained in the PGA InputVoltage Requirements section when the PGA is enabled. Setting the input voltage at or near (AVSS + AVDD) / 2 in most cases satisfies the PGA input voltage requirements. Signals where both the positive and negative inputs are always ≥ 0 V are called unipolar signals. These signals can in general be measured with the ADS114S0xB using a unipolar analog supply (AVSS = 0 V). As mentioned previously, the PGA must be bypassed in order to measure single-ended, unipolar signals when using a unipolar supply. A signal is called bipolar when either the positive or negative input can swing below 0 V. A bipolar analog supply (such as AVDD = 2.5 V, AVSS = –2.5 V) is required in order to measure bipolar signals with the ADS114S0xB. A typical application task is measuring a single-ended, bipolar, ±10-V signal where AINN is fixed at 0 V and AINP swings between –10 V and 10 V. The ADS114S0xB cannot directly measure this signal because the 10-V signal exceeds the analog power-supply limits. However, one possible solution is to use a bipolar analog supply (AVDD = 2.5 V, AVSS = –2.5 V), gain = 1, and a resistor divider in front of the ADS114S0xB. The resistor divider must divide the voltage down to ≤ ±2.5 V to be able to measure the voltage using the internal 2.5-V reference. 10.1.5 Unused Inputs and Outputs To minimize leakage currents on the analog inputs, leave unused analog and reference inputs floating, or connect the inputs to mid-supply or to AVDD. Connecting unused analog or reference inputs to AVSS is possible as well, but can yield higher leakage currents than the previously mentioned options. REFN0 is an exception; leave the REFN0 pin floating when not in use or tie the pin to AVSS. GPIO pins operate on levels based on the analog supply. Do not float GPIO pins that are configured as digital inputs. Tie unused GPIO pins that are configured as digital inputs to the appropriate levels, AVDD or AVSS, including when in power-down mode. Tie unused GPIO output pins to AVSS through a pulldown resistor and set the output to 0 in the GPIO data register. For unused GPIO pins on the ADS114S06B, leave the GPIOCON register set to the default register values and connect these GPIO pins in the same manner as for an unused analog input. Do not float unused digital inputs; excessive power-supply leakage current can result. Tie all unused digital inputs to the appropriate levels, IOVDD or DGND, even when in power-down mode. Connections for unused digital inputs are listed below. • Tie the CS pin to DGND if CS is not used • Tie the CLK pin to DGND if the internal oscillator is used • Tie the START/SYNC pin to DGND to control conversions by commands • Tie the RESET pin to IOVDD if the RESET pin is not used • If the DRDY output is not used, leave the DRDY pin unconnected or tie the DRDY pin to IOVDD using a weak pullup resistor 70 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Application Information (continued) 10.1.6 Pseudo Code Example The following list shows a pseudo code sequence with the required steps to set up the device and the microcontroller that interfaces to the ADC in order to take subsequent readings from the ADS114S0xB in continuous conversion mode. The dedicated DRDY pin is used to indicate availability of new conversion data. Power-up so that all supplies reach minimum operating levels; Delay for a minimum of 2.2 ms to allow power supplies to settle and power-up reset to complete; Configure the SPI interface of the microcontroller to SPI mode 1 (CPOL = 0, CPHA =1); If the CS pin is not tied low permanently, configure the microcontroller GPIO connected to CS as an output; Configure the microcontroller GPIO connected to the DRDY pin as a falling edge triggered interrupt input; Set CS to the device low; Delay for a minimum of td(CSSC); Send the RESET command (06h) to make sure the device is properly reset after power-up; //Optional Delay for a minimum of 4096 · tCLK; Read the status register using the RREG command to check that the RDY bit is 0; //Optional Clear the FL_POR flag by writing 00h to the status register; //Optional Write the respective register configuration with the WREG command; For verification, read back all configuration registers with the RREG command; Send the START command (08h) to start converting in continuous conversion mode; Delay for a minimum of td(SCCS); Clear CS to high (resets the serial interface); Loop { Wait for DRDY to transition low; Take CS low; Delay for a minimum of td(CSSC); Send the RDATA command; Send 16 SCLK rising edges to read out conversion data on DOUT/DRDY; Delay for a minimum of td(SCCS); Clear CS to high; } Take CS low; Delay for a minimum of td(CSSC); Send the STOP command (0Ah) to stop conversions and put the device in standby mode; Delay for a minimum of td(SCCS); Clear CS to high; Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 71 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 10.2 Typical Application Figure 96 shows a fault-protected, filtered, 3-wire RTD application circuit with hardware-based, lead-wire compensation. Two IDAC current sources provide the lead-wire compensation. One IDAC current source (IDAC1) provides excitation to the RTD element. The ADC reference voltage (pins AIN6 and AIN7) is derived from the voltage across resistor RREF sourcing the same IDAC1 current, providing ratiometric cancellation of current-source drift. The other current source (IDAC2) has the same current setting, providing cancellation of lead-wire resistance by generating a voltage drop across lead-wire resistance RLEAD2 equal to the voltage drop of RLEAD1. Because the RRTD voltage is measured differentially at ADC pins AIN1 and AIN2, the voltages across the lead wire resistance cancel. Resistor RBIAS level-shifts the RTD signal to within the ADC specified input range. The current sources are provided by two additional pins (AIN5 and AIN3) that connect to the RTD through blocking diodes. The additional pins are used to route the RTD excitation currents around the input filter resistors, avoiding the voltage drop otherwise caused by the filter resistors RF1 and RF4. The diodes protect the ADC inputs in the event of a miswired connection. The input filter resistors limit the input fault currents flowing into the ADC. 3.3 V 5V 0.1 PF 330 nF IIDAC1 RF4 AVDD IDAC1 AIN5 (IDAC1) AVDD RF3 IOVDD ADS114S08B 500 A CCM4 AIN6 REFOUT (REFP1) RREF DVDD 2.5-V Reference Reference Mux CDIF2 (REFN1) CCM3 REFCOM Reference Buffers 3-Wire RTD RLEAD1 RF2 CCM2 AIN1 (AINP) CDIF1 RRTD RLEAD2 RF1 Input Mux 16-Bit û ADC PGA AIN2 Digital Filter (AINN) Serial Interface and Control CCM1 IIDAC2 AIN3 (IDAC2) IDAC2 START/SYNC RESET CS DIN DOUT/DRDY SCLK DRDY AVDD 4.096-MHz Oscillator 500 A AVSS RLEAD3 1 PF AIN7 DGND CLK IIDAC1 + IIDAC2 Copyright © 2017, Texas Instruments Incorporated RBIAS Figure 96. 3-Wire RTD Application 10.2.1 Design Requirements Table 34 shows the design requirements of the 3-wire RTD application. Table 34. Design Requirements (1) 72 DESIGN PARAMETER VALUE ADC supply voltage 4.75 V (minimum) RTD sensor type 3-wire Pt100 RTD resistance range 20 Ω to 400 Ω RTD lead resistance range 0 Ω to 10 Ω RTD self heating 1 mW Accuracy (1) ±0.1 Ω TA = 25°C. After offset and full-scale calibration. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 10.2.2 Detailed Design Procedure The key considerations in the design of a 3-wire RTD circuit are the accuracy, the lead wire compensation, and the sensor self-heating. As the design values of Table 35 show, several values of excitation currents are available. The resolution is expressed in units of noise-free resolution (NFR). Noise-free resolution is resolution with no code flicker. The selection of excitation currents trades off resolution against sensor self-heating. In general, measurement resolution improves with increasing excitation current. Increasing the excitation current beyond 1000 µA results in no further improvement in resolution for this example circuit. The design procedure is based on a 500-µA excitation current, because this level of current results in very low sensor self-heating (0.4 mW). Table 35. RTD Circuit Design Parameters IIDAC (µA) NFR (bits) PRTD (mW) VRTD (V) Gain (V/V) VREFMIN (1) (V) VREF (2) (V) RREF (kΩ) VAINNLIM (3) (V) VAINPLIM (4) (V) RBIAS (kΩ) VRTDN (5) (V) VRTDP (6) (V) VIDAC1 (7) (V) 50 16.8 0.001 0.02 32 0.64 0.70 18 0.6 4.1 7.10 0.7 0.7 1.9 100 17.8 0.004 0.04 32 1.28 1.41 14.1 0.9 3.8 5.10 1.0 1.1 2.8 250 18.8 0.025 0.10 16 1.60 1.76 7.04 1.1 3.7 2.30 1.2 1.3 3.3 500 19.1 0.100 0.20 8 1.60 1.76 3.52 1.0 3.8 1.10 1.1 1.3 3.4 750 18.9 0.225 0.30 4 1.20 1.32 1.76 0.8 4.0 0.57 0.9 1.2 2.8 1000 19.3 0.400 0.40 4 1.60 1.76 1.76 0.9 3.9 0.50 1.0 1.4 3.5 1500 19.1 0.900 0.60 2 1.20 1.32 0.88 0.6 4.2 0.23 0.7 1.3 3.0 2000 18.3 1.600 0.80 1 0.80 0.90 0.45 0.3 4.5 0.10 0.4 1.2 2.4 (1) (2) (3) (4) (5) (6) (7) VREFMIN is the minimum reference voltage required by the design. VREF is the design target reference voltage allowing for 10% overrange. VAINNLIM is the absolute minimum input voltage required by the ADC. VAINPLIM is the absolute maximum input voltage required by the ADC. VRTDN is the design target negative input voltage. VRTDP is the design target positive input voltage. VIDAC1 is the design target IDAC1 loop voltage. Initially, RLEAD1 and RLEAD2 are considered to be 0 Ω. Route the IDAC1 current through the external reference resistor, RREF. IDAC1 generates the ADC reference voltage, VREF, across the reference resistor. This voltage is defined by Equation 12: VREF = IIDAC1 · RREF (12) Route the second current (IDAC2) to the second RTD lead. Program the IDAC value by using the IDACMAG register; however, only the IDAC1 current flows through the reference resistor and RTD. The IDAC1 current excites the RTD to produce a voltage proportional to the RTD resistance. The RTD voltage is defined by Equation 13: VRTD = RRTD · IIDAC1 (13) The ADC amplifies the RTD signal voltage (VRTD) and measures the resulting voltage against the reference voltage to produce a proportional digital output code, as shown in Equation 14 through Equation 16. Code ∝ VRTD · Gain / VREF Code ∝ (RRTD · IIDAC1) · Gain / (IIDAC1 · RREF) Code ∝ (RRTD · Gain) / RREF (14) (15) (16) As shown in Equation 16, the RTD measurement depends on the value of the RTD, the PGA gain, and the reference resistor RREF, but not on the IDAC1 value. Therefore, the absolute accuracy and temperature drift of the excitation current does not matter. The second excitation current (IDAC2) provides a second voltage drop across the second RTD lead resistance, RLEAD2. The second voltage drop compensates the voltage drop caused by IDAC1 and RLEAD1. The leads of a 3wire RTD typically have the same length; therefore, the lead resistance is typically identical. Taking the lead resistance into account (RLEADx ≠ 0), the differential voltage (VIN) across ADC inputs AIN8 and AIN9 is shown in Equation 17: VIN = IIDAC1 · (RRTD + RLEAD1) – IIDAC2 · RLEAD2 (17) If RLEAD1 = RLEAD2 and IIDAC1 = IIDAC2, the expression for VIN reduces to Equation 18: VIN = IIDAC1 · RRTD (18) Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 73 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com In other words, the measurement error resulting from the voltage drop across the RTD lead resistance is compensated as long as the lead resistance values and the IDAC values are matched. Using Equation 13, the value of RTD resistance (400 Ω, maximum) and the excitation current (500 µA) yields an RTD voltage of VRTD = 500 µA · 400 Ω = 0.2 V. Use the maximum gain of 8 in order to limit the corresponding loop voltage of IDAC1. Gain = 8 requires a minimum reference voltage VREFMIN = 0.2 V · 8 = 1.6 V. To provide margin for the ADC operating range, increase the target reference voltage by 10% (VREF = 1.6 V · 1.1 = 1.76 V). Calculate the value of the reference resistor, as shown in Equation 19: RREF = VREF / IIDAC1 = 1.76 V / 500 µA = 3.52 kΩ (19) For this example application, 3.5 kΩ is chosen for RREF. For best results, use a precision reference resistor RREF with a low temperature drift (< 10 ppm/°C). Any change in RREF is reflected in the measurement as a gain error. The next step in the design is determining the value of the RBIAS resistor, in order to level shift the RTD voltage to meet the ADC absolute input-voltage specification. The required level-shift voltage is determined by calculating the minimum absolute voltage (VAINNLIM) as shown in Equation 20: AVSS + 0.15 + VRTDMAX · (Gain – 1) / 2 ≤ VAINNLIM where • • • VRTDMAX = maximum differential RTD voltage = 0.2 V Gain = 8 AVSS = 0 V (20) The result of the equation requires a minimum absolute input voltage (VRTDN) > 0.85 V. Therefore, the RTD voltage must be level shifted by a minimum of 0.85 V. To meet this requirement, a target level-shift value of 1 V is chosen to provide extra margin. Calculate the value of RBIAS as shown in Equation 21: RBIAS= VAINN / (IIDAC1+ IIDAC2) = 1 V / ( 2 · 500 µA) = 1 kΩ (21) After the level-shift voltage is determined, verify that the positive RTD voltage (VRTDP) is less than the maximum absolute input voltage (VAINPLIM), as shown in Equation 22: VAINPLIM ≤ AVDD – 0.15 – VRTDMAX · (Gain – 1) / 2 where • • • VRTDMAX = maximum differential RTD voltage = 0.2 V Gain = 8 AVDD = 4.75 V (minimum) (22) Solving Equation 22 results in a required VRTDP of less than 3.9 V. Calculate the VRTDP input voltage by Equation 23: VAINP = VRTDN + IIDAC1 · (RRTD + RLEAD1) = 1 V + 500 µA · (400 Ω + 10 Ω) = 1.2 V (23) Because 1.2 V is less than the 3.9-V maximum input voltage limit, the absolute positive and negative RTD voltages are within the ADC specified input range. The next step in the design is to verify that the IDACs have enough voltage headroom (compliance voltage) to operate. The loop voltage of the excitation current must be less than the supply voltage minus the specified IDAC compliance voltage. Calculate the voltage drop developed across each IDAC current path to AVSS. In this circuit, IDAC1 has the largest voltage drop developed across its current path. The IDAC1 calculation is sufficient to satisfy IDAC2 because the IDAC2 voltage drop is always less than IDAC1 voltage drop. The sum of voltages in the IDAC1 loop is shown in Equation 24: VIDAC1 = [(IIDAC1 + IIDAC2) · (RLEAD3 + RBIAS)] + [IIDAC1 · (RRTD + RLEAD1 + RREF)] + VD where • VD = external blocking diode voltage (24) The equation results in a loop voltage of VIDAC1 = 3.0 V. The worst-case current source compliance voltage is: (AVDD – 0.4 V) = (4.75 V – 0.4 V) = 4.35 V. The VIDAC1 loop voltage is less than the specified current source compliance voltage (3.0 V < 4.35 V). 74 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Many applications benefit from using an analog filter at the inputs to remove noise and interference from the signal. Filter components are placed on the ADC inputs (RF1, RF2, CDIF1, CCM1, and CCM2), as well as on the reference inputs (RF3, RF4, CDIF2, CCM3, and CCM4). The filters remove both differential and common-mode noise. The application shows a differential input noise filter formed by RF1, RF2 and CDIF1, with additional differential mode capacitance provided by the common-mode filter capacitors, CCM1 and CCM2. Calculate the differential –3-dB cutoff frequency as shown in Equation 25: fDIF = 1 / [2π · (RF1 + RF2) · (CDIF1 + CCM1|| CCM2)] (25) The common-mode noise filter is formed by components RF1, RF2, CCM1, and CCM2. Calculate the common-mode signal –3-dB cutoff frequency, as shown in Equation 26: fCM = 1 / (2π · RF1 · CCM1) = 1 / (2π · RF2 · CCM2) (26) Mismatches in the common-mode filter components convert common-mode noise into differential noise. To reduce the effect of mismatch, use a differential mode filter with a corner frequency that is at least 10 times lower than the common-mode filter corner frequency. The low-frequency differential filter removes the common-mode converted noise. The filter resistors (RFx) also serve as current-limiting resistors. These resistors limit the current into the analog inputs (AINx) of the device to safe levels when an overvoltage occurs on the inputs. Filter resistors lead to an offset voltage error due to the dc input current leakage flowing into and out of the device. Remove this voltage error by system offset calibration. Resistor values that are too large generate excess thermal noise and degrade the overall noise performance. The recommended range of the filter resistor values is 100 Ω to 10 kΩ. The properties of the capacitors are important because the capacitors are connected to the signal; use high-quality C0G ceramics or film-type capacitors. For consistent noise performance across the full range of RTD measurements, match the corner frequencies of the input and reference filter. See the RTD Ratiometric Measurements and Filtering Using the ADS1148 and ADS1248 Application Report for detailed information on matching the input and reference filter. 10.2.2.1 Register Settings The register settings for this design are shown in Table 36. Table 36. Register Settings REGISTER NAME SETTING 02h INPMUX 12h Select AINP = AIN1 and AINN = AIN2 03h PGA 0Bh PGA enabled, PGA Gain = 8 04h DATARATE 14h Continuous conversion mode, 20-SPS data rate 05h REF 06h Positive and negative reference buffers enabled, REFP1 and REFN1 reference inputs selected, internal reference always on 06h IDACMAG 05h IDAC magnitude set to 500 µA 07h IDACMUX 35h IDAC2 set to AIN3, IDAC1 set to AIN5 08h VBIAS 00h 09h SYS 0Ah 10h (1) xxh 0Bh OFCAL1 xxh 0Ch OFCAL2 xxh 0Dh (1) OFCAL0 FSCAL0 DESCRIPTION (1) xxh 0Eh FSCAL1 0Fh FSCAL2 xxh xxh 10h GPIODAT 00h 11h GPIOCON 00h A two-point offset and gain calibration removes errors from the RREF tolerance. The results are used for the OFC and FSC registers. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 75 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 10.2.3 Application Curves To test the accuracy of the acquisition circuit, a series of calibrated high-precision discrete resistors are used as an input to the system. Measurements are taken at TA = 25°C. Figure 97 displays the resistance measurement over an input span from 20 Ω to 400 Ω. Any offset error is generally attributed to the offset of the ADC, and the gain error can be attributed to the accuracy of the RREF resistor and the ADC. The RREF value is also calibrated to reduce the gain error contribution. Precision temperature measurement applications are typically calibrated to remove the effects of gain and offset errors that generally dominate the total system error. The simplest calibration method is a linear, or two-point calibration that applies an equal and opposite gain and offset term to cancel the measured system gain and offset error. In this particular tested application, the gain and offset error was very small, and did not require additional calibration other than the self offset and gain calibration provided by the device. The resulting measured resistance error is shown in Figure 98. The results in Figure 98 are converted to temperature accuracy by dividing the results by the RTD sensitivity (α) at the measured resistance. Over the full resistance input range, the maximum total measured error is ±0.0190 Ω. Equation 27 uses the measured resistance error and the RTD sensitivity at 0°C to calculate the measured temperature accuracy. Error (°C) = Error (Ω) / α@0°C = ±0.0190 Ω / 0.39083 Ω / °C = ±0.049°C (27) 35000 0.03 30000 0.02 Resistance Error (:) ADC Output (Code) Figure 99 displays the calculated temperature accuracy of the circuit assuming a linear RTD resistance to temperature response. This figure does not include any linearity compensation of the RTD, but Figure 99 does remove offset and gain error, which can be calibrated with the OFC and FSC registers. 25000 20000 15000 10000 0.01 0 -0.01 -0.02 5000 -0.03 0 0 50 100 150 200 250 300 Resistance (:) 350 400 450 Figure 97. ADC Output Code vs Equivalent RTD Resistance 0 50 100 150 200 250 300 Resistance (:) 350 400 450 Figure 98. Measured Resistance Error vs Equivalent RTD Resistance 0.06 Temperature Error (qC) 0.04 0.02 0 -0.02 -0.04 -0.06 0 50 100 150 200 250 300 Resistance (:) 350 400 450 Figure 99. Equivalent Temperature Error vs Equivalent RTD Resistance 76 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 10.3 Do's and Don'ts • • • • • • • • • • Do partition the analog, digital, and power-supply circuitry into separate sections on the PCB. Do use a single ground plane for analog and digital grounds. Do place the analog components close to the ADC pins using short, direct connections. Do keep the SCLK pin free of glitches and noise. Do verify that the analog input voltages are within the specified PGA input voltage range under all input conditions. Do float unused analog input pins to minimize input leakage current on all other analog inputs. Connecting unused pins to AVDD is the next best option. Do provide current limiting to the analog inputs in case overvoltage faults occur. Do use a low-dropout linear regulator (LDO) to reduce ripple voltage generated by switch-mode power supplies. Reducing ripple is especially important for AVDD where the supply noise can affect the performance. Don't cross analog and digital signals. Don't allow the analog and digital power supply voltages to exceed 5.5 V under any condition, including during power-up and power-down. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 77 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com Do's and Don'ts (continued) Figure 100 shows the do's and don'ts of the ADC circuit connections. INCORRECT CORRECT 5V 5V AVDD AVDD Device Device AINP AINP 16-bit û ADC PGA AINN AVSS 0V 16-bit û ADC PGA AINN AVSS 0V 0V 0V Single-ended input, PGA enabled Single-ended input, PGA bypassed CORRECT CORRECT 2.5 V 5V AVDD AVDD Device Device AINP AINP 16-bit û ADC PGA 2.5 V AINN PGA AVSS 16-bit û ADC AVSS 0V -2.5 V 0V Single-ended input, PGA enabled Single-ended input, PGA enabled INCORRECT 5V PGA enabled AINN AVDD 3.3 V 5V INCORRECT 3.3 V DVDD AVDD PGA 16-bit û ADC PGA 16-bit û ADC AVSS DGND AVSS DGND Device CORRECT AVDD 3.3 V DVDD AGND/DGND isolation Inductive supply or ground connections 5V Device 2.5 V CORRECT 3.3 V DVDD AVDD PGA 16-bit û ADC PGA 16-bit û ADC AVSS DGND AVSS DGND Device Device DVDD -2.5 V Low impedance AGND/DGND connection Low impedance AGND/DGND connection Figure 100. Do's and Don'ts Circuit Connections 78 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 11 Power Supply Recommendations 11.1 Power Supplies The ADS114S0xB require three power supplies: analog (AVDD, AVSS), digital core (DVDD, DGND), and digital I/O (IOVDD, DGND). The analog power supply can be bipolar (for example, AVDD = 2.5 V, AVSS = –2.5 V) or unipolar (for example, AVDD = 3.3 V, AVSS = 0 V) and is independent of the digital power supplies. DVDD is used to power the digital circuits of the devices. IOVDD sets the digital I/O levels (with the exception of the GPIO levels that are set by the analog supply of AVDD and AVSS). IOVDD must be equal to or larger than DVDD. 11.2 Power-Supply Sequencing AVDD and DVDD may be powered up in any order. However, IOVDD is recommended to be powered up before or at the same time as DVDD. If DVDD comes up before IOVDD, a reset of the device using the RESET pin or the RESET command may be required. 11.3 Power-On Reset An internal POR is released after all three supplies exceed approximately 1.65 V. Each supply has an individual POR circuit. A brownout condition on any of the three supplies triggers a reset of the complete device. 11.4 Power-Supply Decoupling Good power-supply decoupling is important to achieve best performance. AVDD must be decoupled with at least a 330-nF capacitor to AVSS. DVDD and IOVDD (when not connected to DVDD) must be decoupled with at least a 0.1-μF capacitor to DGND. Figure 101 and Figure 102 show typical power-supply decoupling examples for unipolar and bipolar analog supplies, respectively. Place the bypass capacitors as close to the power-supply pins of the device as possible using low-impedance connections. Use multi-layer ceramic chip capacitors (MLCCs) that offer low equivalent series resistance (ESR) and inductance (ESL) characteristics for power-supply decoupling purposes. To reduce inductance on the supply pins, avoid the use of vias for connecting the capacitors to the supply pins. The use of multiple vias in parallel lowers the overall inductance and is beneficial for connections to ground planes. Connect analog and digital grounds together as close to the device as possible. 23 RESET 24 CLK 17 GPIO3/AIN11 18 GPIO2/AIN10 19 GPIO1/AIN9 20 GPIO0/AIN8 RESET CLK 21 REFOUT GPIO3/AIN11 22 ±2.5 V REFCOM GPIO2/AIN10 23 GPIO1/AIN9 24 GPIO0/AIN8 1 PF REFOUT REFCOM 1 PF 22 21 20 19 18 17 3.3 V NC 5V 25 26 AVDD DVDD 16 IOVDD 15 +2.5 V 0.1 PF 330 nF REFN0 27 AVSS 28 AVSS DGND 29 3.3 V NC 330 nF 14 13 DRDY 12 DOUT/DRDY ±2.5 V 25 DVDD 16 26 AVDD IOVDD 15 27 AVSS DGND 14 28 AVSS 0.1 PF 13 DRDY REFN0 29 12 DOUT/DRDY REFP0 30 11 SCLK REFP1/AIN6 32 9 CS 1 2 3 4 5 6 7 8 Figure 101. Unipolar Analog Power Supply 1 2 3 4 5 6 7 8 START/SYNC CS AIN0 9 AIN1 32 AIN2 REFP1/AIN6 AIN3 DIN AIN4 10 AIN5 31 AINCOM REFN1/AIN7 AIN0 DIN START/SYNC 10 AIN1 31 AIN2 REFN1/AIN7 AIN3 SCLK AIN4 11 AIN5 30 AINCOM REFP0 Figure 102. Bipolar Analog Power Supply Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 79 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 12 Layout 12.1 Layout Guidelines Employing best design practices is recommended when laying out a printed-circuit board (PCB) for both analog and digital components. This recommendation generally means that the layout separates analog components [such as ADCs, amplifiers, references, digital-to-analog converters (DACs), and analog MUXs] from digital components [such as microcontrollers, complex programmable logic devices (CPLDs), field-programmable gate arrays (FPGAs), radio frequency (RF) transceivers, universal serial bus (USB) transceivers, and switching regulators]. An example of good component placement is shown in Figure 103. Although Figure 103 provides a good example of component placement, the best placement for each application is unique to the geometries, components, and PCB fabrication capabilities employed. That is, there is no single layout that is perfect for every design and careful consideration must always be used when designing with any analog component. Ground Fill or Ground Plane Supply Generation Microcontroller Device Optional: Split Ground Cut Signal Conditioning (RC Filters and Amplifiers) Ground Fill or Ground Plane Optional: Split Ground Cut Ground Fill or Ground Plane Interface Transceiver Connector or Antenna Ground Fill or Ground Plane Figure 103. System Component Placement The following basic recommendations for layout of the ADS114S0xB help achieve the best possible performance of the ADC. A good design can be ruined with a bad circuit layout. • Separate analog and digital signals. To start, partition the board into analog and digital sections where the layout permits. Route digital lines away from analog lines. This prevents digital noise from coupling back into analog signals. • The ground plane can be split into an analog plane (AGND) and digital plane (DGND), but this (splitting) is not necessary. Place digital signals over the digital plane, and analog signals over the analog plane. As a final step in the layout, the split between the analog and digital grounds must be connected to together at the ADC. • Fill void areas on signal layers with ground fill. • Provide good ground return paths. Signal return currents will flow on the path of least impedance. If the ground plane is cut or has other traces that block the current from flowing right next to the signal trace, another path must be found to return to the source and complete the circuit. If forced into a larger path, the chance that the signal radiates increases. Sensitive signals are more susceptible to EMI interference. • Use bypass capacitors on supplies to reduce high-frequency noise. Do not place vias between bypass capacitors and the active device. Placing the bypass capacitors on the same layer as close to the active device yields the best results. • Consider the resistance and inductance of the routing. Often, traces for the inputs have resistances that react with the input bias current and cause an added error voltage. Reducing the loop area enclosed by the source signal and the return current reduces the inductance in the path. Reducing the inductance reduces the EMI pickup and reduces the high-frequency impedance at the input of the device. • Watch for parasitic thermocouples in the layout. Dissimilar metals going from each analog input to the sensor can create a parasitic themocouple that can add an offset to the measurement. Differential inputs must be matched for both the inputs going to the measurement source. • Analog inputs with differential connections must have a capacitor placed differentially across the inputs. Best input combinations for differential measurements use adjacent analog input lines (such as AIN0, AIN1 and AIN2, AIN3). The differential capacitors must be of high quality. The best ceramic chip capacitors are C0G (NPO) that have stable properties and low noise characteristics. 80 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 Reference input REFN0 REFP0 Differential input or Reference input AIN7 AIN6 12.2 Layout Example Internal plane connected to GND (DGND = AVSS) Via connection to power plane AIN5 Differential input Differential input 25: NC 27: AVSS 26: AVDD 29: REFN0 28: AVSS 30: REFP0 32: REFP1/ AIN6 31: REFN1/ AIN7 AIN8 AIN4 1: AINCOM 24: REFCOM 2: AIN5 23: REFOUT 3: AIN4 22: GPIO0/ AIN8 4: AIN3 21: GPIO1/ AIN9 5: AIN2 20: GPIO2/ AIN10 6: AIN1 19: GPIO3/ AIN11 7: AIN0 18: RESET 8: START 17: CLK AIN9 AIN3 Differential input AIN10 Differential input 16: DVDD 15: IOVDD 14: DGND 13: DRDY 11: SCLK 12: DOUT/ DRDY 10: DIN 9: CS AIN2 AIN11 AIN1 Differential input AIN0 RESET CLK DRDY DOUT/DRDY SCLK DIN CS START Digital connections Figure 104. ADS114S0xB Layout Example Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 81 ADS114S06B, ADS114S08B SBAS852 – AUGUST 2017 www.ti.com 13 Device and Documentation Support 13.1 Device Support 13.1.1 Development Support ADS1x4S0x Design Calculator 13.2 Documentation Support 13.2.1 Related Documentation For related documentation see the following: • ADS114S0x Low-Power, Low-Noise, Highly Integrated, 6- and 12-Channel, 4-kSPS, 16-Bit, Delta-Sigma ADC with PGA and Voltage Reference • ADS124S0x Low-Power, Low-Noise, Highly Integrated, 6- and 12-Channel, 4-kSPS, 24-Bit, Delta-Sigma ADC with PGA and Voltage Reference • REF50xx Low-Noise, Very Low Drift, Precision Voltage Reference • RTD Ratiometric Measurements and Filtering Using the ADS1148 and ADS1248 Application Report • 3-Wire RTD Measurement System Reference Design, -200°C to 850°C 13.3 Related Links The table below lists quick access links. Categories include technical documents, support and community resources, tools and software, and quick access to order now. Table 37. Related Links PARTS PRODUCT FOLDER ORDER NOW TECHNICAL DOCUMENTS TOOLS & SOFTWARE SUPPORT & COMMUNITY ADS114S06B Click here Click here Click here Click here Click here ADS114S08B Click here Click here Click here Click here Click here 13.4 Receiving Notification of Documentation Updates To receive notification of documentation updates, navigate to the device product folder on ti.com. In the upper right corner, click on Alert me to register and receive a weekly digest of any product information that has changed. For change details, review the revision history included in any revised document. 13.5 Community Resources The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support. 13.6 Trademarks E2E is a trademark of Texas Instruments. All other trademarks are the property of their respective owners. 13.7 Electrostatic Discharge Caution This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. 82 Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B ADS114S06B, ADS114S08B www.ti.com SBAS852 – AUGUST 2017 13.8 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions. 14 Mechanical, Packaging, and Orderable Information The following pages include mechanical packaging and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. Submit Documentation Feedback Copyright © 2017, Texas Instruments Incorporated Product Folder Links: ADS114S06B ADS114S08B 83 PACKAGE OPTION ADDENDUM www.ti.com 15-Aug-2017 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish MSL Peak Temp (2) (6) (3) Op Temp (°C) Device Marking (4/5) ADS114S06BIPBS PREVIEW TQFP PBS 32 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 114S06B ADS114S06BIPBSR PREVIEW TQFP PBS 32 1000 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 114S06B ADS114S06BIRHBR ACTIVE VQFN RHB 32 3000 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 ADS 114S06B ADS114S06BIRHBT ACTIVE VQFN RHB 32 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 ADS 114S06B ADS114S08BIPBS PREVIEW TQFP PBS 32 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 114S08B ADS114S08BIPBSR PREVIEW TQFP PBS 32 1000 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 114S08B ADS114S08BIRHBR ACTIVE VQFN RHB 32 3000 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 ADS 114S08B ADS114S08BIRHBT ACTIVE VQFN RHB 32 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-3-260C-168 HR -40 to 125 ADS 114S08B (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of <=1000ppm threshold. Antimony trioxide based flame retardants must also meet the <=1000ppm threshold requirement. (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 15-Aug-2017 (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 17-Aug-2017 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing ADS114S06BIRHBR VQFN RHB 32 SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant 3000 330.0 12.4 5.3 5.3 1.1 8.0 12.0 Q2 ADS114S06BIRHBT VQFN RHB 32 250 180.0 12.4 5.3 5.3 1.1 8.0 12.0 Q2 ADS114S08BIRHBR VQFN RHB 32 3000 330.0 12.4 5.3 5.3 1.1 8.0 12.0 Q2 ADS114S08BIRHBT VQFN RHB 32 250 180.0 12.4 5.3 5.3 1.1 8.0 12.0 Q2 Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 17-Aug-2017 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) ADS114S06BIRHBR VQFN RHB 32 3000 367.0 367.0 35.0 ADS114S06BIRHBT VQFN RHB 32 250 210.0 185.0 35.0 ADS114S08BIRHBR VQFN RHB 32 3000 367.0 367.0 35.0 ADS114S08BIRHBT VQFN RHB 32 250 210.0 185.0 35.0 Pack Materials-Page 2 IMPORTANT NOTICE Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. TI’s published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and services. Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyers and others who are developing systems that incorporate TI products (collectively, “Designers”) understand and agree that Designers remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products used in or for Designers’ applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will thoroughly test such applications and the functionality of such TI products as used in such applications. TI’s provision of technical, application or other design advice, quality characterization, reliability data or other services or information, including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any way, Designer (individually or, if Designer is acting on behalf of a company, Designer’s company) agrees to use any particular TI Resource solely for this purpose and subject to the terms of this Notice. TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections, enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically described in the published documentation for a particular TI Resource. Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. TI RESOURCES ARE PROVIDED “AS IS” AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM, INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949 and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements. Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use. Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S. TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product). Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications and that proper product selection is at Designers’ own risk. Designers are solely responsible for compliance with all legal and regulatory requirements in connection with such selection. Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer’s noncompliance with the terms and provisions of this Notice. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2017, Texas Instruments Incorporated