Renesas M37516E3-XXXHP Single-chip 8-bit cmos microcomputer Datasheet

7516 Group
REJ03B0042-0101Z
Rev.1.01
Jul 01, 2003
SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER
DESCRIPTION
●Clock generating circuit ..................................... Built-in 2 circuits
(connect to external ceramic resonator or quartz-crystal oscillator)
●Power source voltage
In high-speed mode .................................................. 4.0 to 5.5 V
(at 8 MHz oscillation frequency)
In high-speed mode .................................................. 2.7 to 5.5 V
(at 4 MHz oscillation frequency)
In middle-speed mode ............................................... 2.7 to 5.5 V
(at 8 MHz oscillation frequency)
In low-speed mode .................................................... 2.7 to 5.5 V
(at 32 kHz oscillation frequency)
●Power dissipation
In high-speed mode .......................................................... 34 mW
(at 8 MHz oscillation frequency, at 5 V power source voltage)
In low-speed mode
Except M37516F8HP ........................................................ 60 µW
M37516F8HP .................................................................. 450 µW
(at 32 kHz oscillation frequency, at 3 V power source voltage)
●Operating temperature range .................................... –20 to 85°C
The 7516 group is the 8-bit microcomputer based on the 740 family core technology.
The 7516 group is designed for the household products and office
automation equipment and includes serial I/O functions, 8-bit
timer, A-D converter, and I2C-BUS interface.
FEATURES
●Basic machine-language instructions ...................................... 71
●Minimum instruction execution time .................................. 0.5 µs
(at 8 MHz oscillation frequency)
●Memory size
ROM ............................................................... 16 K to 32 K bytes
RAM .................................................................... 512 to 1 K bytes
●Programmable input/output ports ............................................ 40
●Interrupts ................................................. 17 sources, 16 vectors
●Timers ............................................................................. 8-bit ✕ 4
●Serial I/O1 ................... 8-bit ✕ 1 (UART or Clock-synchronized)
●Serial I/O2 ................................... 8-bit ✕ 1(Clock-synchronized)
●Multi-master I2C-BUS interface (option) ...................... 1 channel
●PWM ............................................................................... 8-bit ✕ 1
●A-D converter ............................................... 10-bit ✕ 8 channels
●Watchdog timer ............................................................ 16-bit ✕ 1
P11/(LED1)
P05
P10/(LED0)
P04
29
25
P03/SRDY2
30
26
P02/SCLK2
31
P06
P01/SOUT2
32
P07
P00/SIN2
33
27
P37/AN7
34
28
P36/AN6
35
Office automation equipment, FA equipment, Household products,
Consumer electronics, etc.
36
PIN CONFIGURATION (TOP VIEW)
APPLICATION
P35/AN5
37
24
P12/(LED2)
P34/AN4
38
23
P13/(LED3)
P33/AN3
39
22
P14/(LED4)
P32/AN2
40
21
P15/(LED5)
P31/AN1
41
20
P16/(LED6)
P30/AN0
42
19
P17/(LED7)
VCC
43
18
VSS
VREF
44
17
XOUT
AVSS
45
16
XIN
P47
46
15
RESET
P46
47
14
P20/XCOUT
P45
48
13
P21/XCIN
1
2
3
4
5
6
7
8
9
10
11
12
P44/INT3/PWM
P43/INT2/SCMP2
P42/INT1
P41/INT0
P40/CNTR1
P27/CNTR0/SRDY1
P26/SCLK
P25/SCL2/TXD
P24/SDA2/RXD
P23/SCL1
P22/SDA1
CNVSS
M37516M8-XXXHP
Package type : 48P6Q-A
Fig. 1 M37516F8HP pin configuration
Rev.1.01
Jul 01, 2003
page 1 of 89
Rev.1.01
Jul 01, 2003
Reset
RAM
ROM
Fig.2 Functional block diagram
page 2 of 89
A-D
VREF AVSS
44 45
(1 0 )
converter
PWM (8)
Sub-clock
output
Sub-clock
input
Watchdog timer
XCOUT
XCIN
I/O port P3
35 36 37 38 39 40 41 42
46 47 48 1 2 3 4 5
I/O port P 4
P3(8)
0
PCH
P4(8)
INT0–INT3
(Flash)
18
17
16
Clock generating circuit
VSS
Main-clock
output
XOUT
XIN
Main-clock
input
FUNCTIONAL BLOCK DIAGRAM
PS
PCL
S
Y
X
A
SI/O1(8)
C P U
43
VCC
I2C
(8)
XCIN XCOUT
CNTR1
I/O port P 2
P1(8)
I/O port P 1
P0(8)
I/O port P 0
27 28 29 30 31 32 33 34
Timer Y (8)
Timer X (8)
Timer 2 (8)
Timer 1 (8)
19 20 21 22 23 24 25 26
Prescaler Y (8)
Prescaler X (8)
Prescaler 12 (8)
12
CNVSS
6 7 8 9 10 11 13 14
P2(8)
CNTR0
15
RESET
Reset input
SI/O2(8)
7516 Group
FUNCTIONAL BLOCK
7516 Group
Table 1 Pin description
Pin
Functions
Name
VCC, VSS
CNVSS
Power source
CNVSS input
•Apply voltage of 2.7 V – 5.5 V to Vcc, and 0 V to Vss.
Reference
voltage input
Analog power
source input
Reset input
Clock input
•Reference voltage input pin for A-D converter.
Function except a port function
•This pin controls the operation mode of the chip.
•Normally connected to VSS.
VREF
AVss
RESET
XIN
XOUT
Clock output
P00/SIN2
P01/SOUT2
P02/SCLK2
P03/SRDY2
I/O port P0
•Analog power source input pin for A-D converter.
•Connect to Vss.
•Reset input pin for active “L”.
•Input and output pins for the clock generating circuit.
•Connect a ceramic resonator or quartz-crystal oscillator between the XIN and XOUT pins to set
the oscillation frequency.
•When an external clock is used, connect the clock source to the XIN pin and leave the XOUT
pin open.
• Serial I/O2 function pin
•8-bit CMOS I/O port.
•I/O direction register allows each pin to be individually
programmed as either input or output.
P04–P07
P10–P17
I/O port P1
P20/XCOUT
P21/XCIN
I/O port P2
P22/SDA1
P23/SCL1
P24/SDA2/RxD
P25/SCL2/TxD
•CMOS compatible input level.
•CMOS 3-state output structure.
•P10 to P17 (8 bits) are enabled to output large current for LED drive.
• Sub-clock generating circuit I/O
•8-bit CMOS I/O port.
pins (connect a resonator)
•I/O direction register allows each pin to be individually
• I2C-BUS interface function pins
programmed as either input or output.
•CMOS compatible input level.
•P22 to P25 can be switched between CMOS compatible input level or SMBUS input level in the I2C-BUS
interface function.
P26/SCLK
•P20, P21, P24 to P27: CMOS 3-state output structure.
P27/CNTR0/
SRDY1
•P24, P25: N-channel open-drain structure in the I2CBUS interface function.
P30/AN0–
P37/AN7
I/O port P3
P40/CNTR1
I/O port P4
•P22, P23: N-channel open-drain structure.
•8-bit CMOS I/O port with the same function as port P0.
• I2C-BUS interface function pin/
Serial I/O1 function pins
• Serial I/O1 function pin
• Serial I/O1 function pin/
Timer X function pin
• A-D converter input pin
•CMOS compatible input level.
•CMOS 3-state output structure.
P41/INT0
P42/INT1
•8-bit CMOS I/O port with the same function as port P0.
•CMOS compatible input level.
P43/INT2/SCMP2
•CMOS 3-state output structure.
• Interrupt input pin/SCMP2 output pin
• Interrupt input pin/PWM output pin
P44/INT3/PWM
P45–P47
Rev.1.01
Jul 01, 2003
• Timer Y function pin
• Interrupt input pins
page 3 of 89
7516 Group
PART NUMBERING
Product name
M37516 M 8 – XXX HP
Package type
HP : 48P6Q-A
ROM number
Omitted in One Time PROM version shipped in blank and
flash memory version.
– : standard
Omitted in One Time PROM version shipped in blank and
flash memory version.
ROM/PROM/Flash memory size
9 : 36864 bytes
1 : 4096 bytes
A: 40960 bytes
2 : 8192 bytes
B: 45056 bytes
3 : 12288 bytes
C: 49152 bytes
4 : 16384 bytes
:
20480
bytes
D: 53248 bytes
5
:
24576
bytes
E: 57344 bytes
6
F : 61440 bytes
7 : 28672 bytes
8 : 32768 bytes
The first 128 bytes and the last 2 bytes of ROM are reserved areas ; they
cannot be used as a user’s ROM area.
However, they can be programmed or erased in the flash memory version,
so that the users can use them.
Memory type
M : Mask ROM version
E : One Time PROM version
F : Flash memory version
Differences of functions
Fig. 3 Part numbering
Rev.1.01
Jul 01, 2003
page 4 of 89
7516 Group
GROUP EXPANSION
Packages
Mitsubishi plans to expand the 7516 group as follows.
48P6Q-A ............................................... 48-pin plastic-molded QFP
Memory Type
Support for mask ROM, One Time PROM, and flash memory versions.
Memory Size
Flash memory size ......................................................... 32 K bytes
Mask ROM size ................................................. 16 K to 32 K bytes
One Time PROM size ..................................................... 24 K bytes
RAM size ............................................................... 512 to 1 K bytes
Memory Expansion Plan
ROM size (bytes)
As of Aug. 2002
ROM
exteranal
New product
M37516M8/F8
32K
28K
Mass production
M37516M6/E6
24K
20K
Mass production
M37516M4
16K
12K
8K
384
512
Fig. 4 Memory expansion plan
Rev.1.01
Jul 01, 2003
page 5 of 89
640
768
896
1024
1152
RAM size (bytes)
1280
1408
1536
2048
7516 Group
Currently planning products are listed below.
Table 2 Support products
As of Jul. 2003
Product name
ROM size (bytes)
ROM size for User in ( )
RAM size (bytes)
M37516M4-XXXHP
16384
(16254)
512
24576
(24446)
640
32768
(32638)
1024
M37516M6-XXXHP
M37516E6-XXXHP
M37516E6HP
M37516M8-XXXHP
M37516F8HP
Rev.1.01
Jul 01, 2003
page 6 of 89
Package
Remarks
Mask ROM version
48P6Q-A
One Time PROM version
One Time PROM version (blank)
Mask ROM version
Flash memory version
7516 Group
FUNCTIONAL DESCRIPTION
CENTRAL PROCESSING UNIT (CPU)
[Stack Pointer (S)]
The 7516 group uses the standard 740 Family instruction set. Refer to the table of 740 Family addressing modes and machine
instructions or the 740 Family Software Manual for details on the
instruction set.
Machine-resident 740 Family instructions are as follows:
The FST and SLW instructions cannot be used.
The STP, WIT, MUL, and DIV instructions can be used.
[Accumulator (A)]
The accumulator is an 8-bit register. Data operations such as data
transfer, etc., are executed mainly through the accumulator.
[Index Register X (X)]
The index register X is an 8-bit register. In the index addressing
modes, the value of the OPERAND is added to the contents of
register X and specifies the real address.
[Index Register Y (Y)]
The stack pointer is an 8-bit register used during subroutine calls
and interrupts. This register indicates start address of stored area
(stack) for storing registers during subroutine calls and interrupts.
The low-order 8 bits of the stack address are determined by the
contents of the stack pointer. The high-order 8 bits of the stack address are determined by the stack page selection bit. If the stack
page selection bit is “0” , the high-order 8 bits becomes “0016”. If
the stack page selection bit is “1”, the high-order 8 bits becomes
“0116”.
The operations of pushing register contents onto the stack and
popping them from the stack are shown in Figure 6.
Store registers other than those described in Figure 6 with program when the user needs them during interrupts or subroutine
calls.
[Program Counter (PC)]
The program counter is a 16-bit counter consisting of two 8-bit
registers PC H and PCL . It is used to indicate the address of the
next instruction to be executed.
The index register Y is an 8-bit register. In partial instruction, the
value of the OPERAND is added to the contents of register Y and
specifies the real address.
b0
b7
A
Accumulator
b0
b7
X
Index register X
b0
b7
Y
b7
Index register Y
b0
S
b15
b7
Stack pointer
b0
PCL
PCH
b7
Program counter
b0
N V T B D I Z C
Processor status register (PS)
Carry flag
Zero flag
Interrupt disable flag
Decimal mode flag
Break flag
Index X mode flag
Overflow flag
Negative flag
Fig. 5 740 Family CPU register structure
Rev.1.01
Jul 01, 2003
page 7 of 89
7516 Group
On-going Routine
Interrupt request
(Note)
M (S)
Execute JSR
Push return address
on stack
M (S)
(PCH)
(S)
(S) – 1
M (S)
(PCL)
(S)
(S)– 1
(S)
M (S)
(S)
M (S)
(S)
Subroutine
(S)
(S) + 1
(PCL)
M (S)
(S)
(S) + 1
(PCH)
M (S)
(S) – 1
(PCL)
Push return address
on stack
(S) – 1
(PS)
Push contents of processor
status register on stack
(S) – 1
Interrupt
Service Routine
Execute RTS
POP return
address from stack
(PCH)
I Flag is set from “0” to “1”
Fetch the jump vector
Execute RTI
Note: Condition for acceptance of an interrupt
(S)
(S) + 1
(PS)
M (S)
(S)
(S) + 1
(PCL)
M (S)
(S)
(S) + 1
(PCH)
M (S)
POP contents of
processor status
register from stack
POP return
address
from stack
Interrupt enable flag is “1”
Interrupt disable flag is “0”
Fig. 6 Register push and pop at interrupt generation and subroutine call
Table 3 Push and pop instructions of accumulator or processor status register
Push instruction to stack
Pop instruction from stack
Accumulator
PHA
PLA
Processor status register
PHP
PLP
Rev.1.01
Jul 01, 2003
page 8 of 89
7516 Group
[Processor status register (PS)]
The processor status register is an 8-bit register consisting of 5
flags which indicate the status of the processor after an arithmetic
operation and 3 flags which decide MCU operation. Branch operations can be performed by testing the Carry (C) flag , Zero (Z) flag,
Overflow (V) flag, or the Negative (N) flag. In decimal mode, the Z,
V, N flags are not valid.
•Bit 0: Carry flag (C)
The C flag contains a carry or borrow generated by the arithmetic
logic unit (ALU) immediately after an arithmetic operation. It can
also be changed by a shift or rotate instruction.
•Bit 1: Zero flag (Z)
The Z flag is set if the result of an immediate arithmetic operation
or a data transfer is “0”, and cleared if the result is anything other
than “0”.
•Bit 2: Interrupt disable flag (I)
The I flag disables all interrupts except for the interrupt
generated by the BRK instruction.
Interrupts are disabled when the I flag is “1”.
•Bit 3: Decimal mode flag (D)
The D flag determines whether additions and subtractions are
executed in binary or decimal. Binary arithmetic is executed when
this flag is “0”; decimal arithmetic is executed when it is “1”.
Decimal correction is automatic in decimal mode. Only the ADC
and SBC instructions can be used for decimal arithmetic.
•Bit 4: Break flag (B)
The B flag is used to indicate that the current interrupt was
generated by the BRK instruction. The BRK flag in the processor
status register is always “0”. When the BRK instruction is used to
generate an interrupt, the processor status register is pushed
onto the stack with the break flag set to “1”.
•Bit 5: Index X mode flag (T)
When the T flag is “0”, arithmetic operations are performed
between accumulator and memory. When the T flag is “1”, direct
arithmetic operations and direct data transfers are enabled
between memory locations.
•Bit 6: Overflow flag (V)
The V flag is used during the addition or subtraction of one byte
of signed data. It is set if the result exceeds +127 to -128. When
the BIT instruction is executed, bit 6 of the memory location
operated on by the BIT instruction is stored in the overflow flag.
•Bit 7: Negative flag (N)
The N flag is set if the result of an arithmetic operation or data
transfer is negative. When the BIT instruction is executed, bit 7 of
the memory location operated on by the BIT instruction is stored
in the negative flag.
Table 4 Set and clear instructions of each bit of processor status register
C flag
Set instruction
Clear instruction
Rev.1.01
Jul 01, 2003
Z flag
_
I flag
D flag
V flag
SEI
SED
B flag
_
T flag
SEC
SET
_
N flag
_
CLC
_
CLI
CLD
_
CLT
CLV
_
page 9 of 89
7516 Group
[CPU Mode Register (CPUM)] 003B16
The CPU mode register contains the stack page selection bit, etc.
The CPU mode register is allocated at address 003B16.
b7
b0
1
CPU mode register
(CPUM : address 003B16)
Processor mode bits
b1 b0
0 0 : Single-chip mode
0 1:
1 0:
Not available
1 1:
Stack page selection bit
0 : 0 page
1 : 1 page
Fix this bit to “1”.
Port XC switch bit
0 : I/O port function (stop oscillating)
1 : XCIN–XCOUT oscillating function
Main clock (XIN–XOUT) stop bit
0 : Oscillating
1 : Stopped
Main clock division ratio selection bits
b7 b6
0 0 : φ = f(XIN)/2 (high-speed mode)
0 1 : φ = f(XIN)/8 (middle-speed mode)
1 0 : φ = f(XCIN)/2 (low-speed mode)
1 1 : Not available
Fig. 7 Structure of CPU mode register
Rev.1.01
Jul 01, 2003
page 10 of 89
7516 Group
MEMORY
Special Function Register (SFR) Area
Interrupt Vector Area
The interrupt vector area contains reset and interrupt vectors.
The Special Function Register area in the zero page contains control registers such as I/O ports and timers.
Zero Page
RAM
Access to this area with only 2 bytes is possible in the zero page
addressing mode.
RAM is used for data storage and for stack area of subroutine
calls and interrupts.
Special Page
ROM
Access to this area with only 2 bytes is possible in the special
page addressing mode.
The first 128 bytes and the last 2 bytes of ROM are reserved for
device testing and the rest is user area for storing programs.
Product name
M37516M4
M37516M6/E6
M37516M8/F8
RAM size
512 bytes
640 bytes
1024 bytes
ROM size
16 Kbytes
24 Kbytes
32 Kbytes
000016
SFR area
Zero page
004016
RAM
010016
RAM area
RAM size
(bytes)
512
640
1024
Address
XXXX16
023F16
02BF16
043F16
XXXX16
Not used
ROM area
ROM size
(bytes)
16384
24576
32768
Address
YYYY16
C00016
A00016
800016
0FF016
0FFF16
Address
ZZZZ16
C08016
A08016
808016
SFR area (Note)
Not used
YYYY16
Reserved ROM area
(128 bytes)
ZZZZ16
ROM
FF0016
Special page
FFDC16
Interrupt vector area
FFFE16
FFFF16
Reserved ROM area
Note: Flash memory version only
Fig. 8 Memory map diagram
Rev.1.01
Jul 01, 2003
page 11 of 89
7516 Group
000016
Port P0 (P0)
002016
Prescaler 12 (PRE12)
000116
Port P0 direction register (P0D)
002116
Timer 1 (T1)
000216
Port P1 (P1)
002216
Timer 2 (T2)
000316
Port P1 direction register (P1D)
002316
Timer XY mode register (TM)
000416
Port P2 (P2)
002416
Prescaler X (PREX)
000516
Port P2 direction register (P2D)
002516
Timer X (TX)
000616
Port P3 (P3)
002616
Prescaler Y (PREY)
000716
Port P3 direction register (P3D)
002716
Timer Y (TY)
000816
Port P4 (P4)
002816
Timer count source selection register (TCSS)
000916
Port P4 direction register (P4D)
002916
000A16
002A16
000B16
002B16
I2C data shift register (S0)
000C16
002C16
I2C address register (S0D)
000D16
002D16
I2C status register (S1)
000E16
002E16
I2C control register (S1D)
000F16
002F16
I2C clock control register (S2)
001016
003016
I2C start/stop condition control register (S2D)
003116
Reserved ✽
001116
001216
Reserved ✽
003216
001316
Reserved ✽
003316
001416
Reserved ✽
003416
A-D control register (ADCON)
001516
Serial I/O2 control register 1 (SIO2CON1)
003516
A-D conversion low-order register (ADL)
001616
Serial I/O2 control register 2 (SIO2CON2)
003616
A-D conversion high-order register (ADH)
001716
Serial I/O2 register (SIO2)
003716
Reserved ✽
001816
Transmit/Receive buffer register (TB/RB)
003816
MISRG
001916
Serial I/O1 status register (SIOSTS)
003916
Watchdog timer control register (WDTCON)
001A16
Serial I/O1 control register (SIOCON)
003A16
Interrupt edge selection register (INTEDGE)
001B16
UART control register (UARTCON)
003B16
CPU mode register (CPUM)
001C16
Baud rate generator (BRG)
003C16
Interrupt request register 1 (IREQ1)
001D16
PWM control register (PWMCON)
003D16
Interrupt request register 2 (IREQ2)
001E16
PWM prescaler (PREPWM)
003E16
Interrupt control register 1 (ICON1)
001F16
PWM register (PWM)
003F16
Interrupt control register 2 (ICON2)
✽ Reserved : Do not write any data to the reserved area.
Fig. 9 Memory map of special function register (SFR)
Rev.1.01
Jul 01, 2003
page 12 of 89
0FFD16
Reserved ✽
0FFE16
Flash memory control register (FCON)
0FFF16
Reserved ✽
7516 Group
I/O PORTS
The I/O ports have direction registers which determine the input/
output direction of each individual pin. Each bit in a direction register corresponds to one pin, and each pin can be set to be input
port or output port.
When “0” is written to the bit corresponding to a pin, that pin becomes an input pin. When “1” is written to that bit, that pin
becomes an output pin.
If data is read from a pin which is set to output, the value of the
port output latch is read, not the value of the pin itself. Pins set to
input are floating. If a pin set to input is written to, only the port
output latch is written to and the pin remains floating.
Table 5 I/O port function
Pin
P00/SIN2
P01/SOUT2
P02/SCLK2
P03/SRDY2
Name
Input/Output
Port P0
Input/output,
individual
bits
I/O Structure
CMOS compatible
input level
CMOS 3-state output
Non-Port Function
Related SFRs
Serial I/O2 control
register
(1)
(2)
(3)
(4)
(5)
Sub-clock generating
circuit
CPU mode register
CMOS compatible
input level
CMOS/SMBUS input
level (when selecting
I2C-BUS interface
function)
N-channel open-drain
output
CMOS compatible
input level
CMOS/SMBUS input
level (when selecting
I2C-BUS interface
function)
CMOS 3-state output
N-channel open-drain
output (when
selecting I2C-BUS
interface function)
I2C-BUS interface function I/O
I2C control register
(6)
(7)
(8)
(9)
I2C-BUS interface function I/O
I2C control register
Serial I/O1 control
register
(10)
(11)
CMOS compatible
input level
CMOS 3-state output
Serial I/O1 function I/O
Serial I/O1 control
register
Serial I/O1 control
register
Timer XY mode register
A-D control register
(12)
Timer XY mode register
Interrupt edge selection
register
Interrupt edge selection
register
Serial I/O2 control
register
Interrupt edge selection
register
PWM control register
(15)
P04–P07
P10–P17
Port P1
P20/XCOUT
P21/XCIN
Port P2
P22/SDA1
P23/SCL1
P24/SDA2/RxD
P25/SCL2/TxD
P26/SCLK
P27/CNTR0/
SRDY1
Serial I/O1 function I/O
Serial I/O1 function I/O
Timer X function I/O
P30/AN0–
P37/AN7
Port P3
A-D conversion input
P40/CNTR1
P41/INT0
P42/INT1
Port P4
Timer Y function I/O
External interrupt input
P43/INT2/SCMP2
External interrupt input
SCMP2 output
P44/INT3/PWM
External interrupt input
PWM output
P45–P47
Rev.1.01
Ref.No.
Serial I/O2 function I/O
(13)
(14)
(16)
(17)
(18)
(5)
Jul 01, 2003
page 13 of 89
7516 Group
(1) Port P00
(2) Port P01
P01/SOUT2 P-channel output
disable bit
Direction
register
Serial I/O2 transmit completion signal
Serial I/O2 port selection bit
Data bus
Direction
register
Port latch
Data bus
Port latch
Serial I/O2 input
Serial I/O2 output
(3) Port P02
P02/SCLK2 P-channel output disable bit
(4) Port P03
Serial I/O2 synchronous clock
selection bit
Serial I/O2 port selection bit
SRDY2 output enable bit
Direction
register
Direction
register
Data bus
Data bus
Port latch
Port latch
Serial I/O2 ready output
Serial I/O2 clock output
Serial I/O2 external clock input
(5) Ports P04–P07, P1, P45–P47
(6) Port P20
Port XC switch bit
Direction
register
Port latch
Data bus
Direction
register
Data bus
Port latch
Oscillator
Port P21
Port XC switch bit
(7) Port P21
(8) Port P22
Port XC switch bit
I2C-BUS interface enable bit
SDA/SCL pin selection bit
Direction
register
Data bus
Direction
register
Port latch
Data bus
Port latch
Sub-clock generating circuit input
SDA output
SDA input
Fig. 10 Port block diagram (1)
Rev.1.01
Jul 01, 2003
page 14 of 89
7516 Group
(9) Port P23
(10) Port P24
I2C-BUS interface enable bit
SDA/SCL pin selection bit
I2C-BUS interface enable bit
SDA/SCL pin selection bit
Serial I/O1 enable bit
Receive enable bit
Direction
register
Data bus
Direction
register
Port latch
Data bus
Port latch
SDA output
SCL output
SCL input
(11) Port P25
(12) Port P26
P-channel output disable bit
Serial I/O1 synchronous clock
selection bit
Serial I/O1 enable bit
Serial I/O1 enable bit
Transmit enable bit
I2C-BUS interface enable bit
SDA/SCL pin selection bit
Serial I/O1 mode selection bit
Serial I/O1 enable bit
Direction
register
Data bus
SDA input
Serial I/O1 input
Direction
register
Port latch
Data bus
SCL input
Serial I/O1 output
Port latch
Serial I/O1 clock output
External clock input
SCL output
(13) Port P27
(14) Ports P30–P37
Pulse output mode
Serial I/O1 mode selection bit
Serial I/O1 enable bit
SRDY1 output enable bit
Direction
register
Direction
register
Data bus
Port latch
Data bus
Port latch
Pulse output mode
A-D converter input
CNTR0
interrupt input
Serial ready output
Analog input pin
selection bit
Timer output
(16) Ports P41, P42
(15) Port P40
Direction
register
Data bus
Direction
register
Data bus
Port latch
Pulse output mode
Timer output
Interrupt input
CNTR1 interrupt input
Fig. 11 Port block diagram (2)
Rev.1.01
Jul 01, 2003
Port latch
page 15 of 89
7516 Group
(17) Port P43
(18) Port P44
PWM output enable bit
Serial I/O2 input/output
comparison signal control bit
Direction
register
Direction
register
Data bus
Data bus
Port latch
Port latch
PWM output
Serial I/O2 input/output
comparison signal output
Interrupt input
Interrupt input
Fig. 12 Port block diagram (3)
Rev.1.01
Jul 01, 2003
page 16 of 89
7516 Group
INTERRUPTS
■Notes
Interrupts occur by 17 sources among 17 sources: seven external,
nine internal, and one software.
When setting the followings, the interrupt request bit may be set to
“1”.
•When setting external interrupt active edge
Related register: Interrupt edge selection register (address 3A16)
I2C start/stop condition control register (address 3016)
Timer XY mode register (address 2316)
•When switching interrupt sources of an interrupt vector address
where two or more interrupt sources are allocated
Related register: Interrupt edge selection register (address 3A16)
When not requiring for the interrupt occurrence synchronized with
these setting, take the following sequence.
➀Set the corresponding interrupt enable bit to “0” (disabled).
➁Set the interrupt edge select bit or the interrupt source select bit.
➂Set the corresponding interrupt request bit to “0” after 1 or more
instructions have been executed.
➃Set the corresponding interrupt enable bit to “1” (enabled).
Interrupt Control
Each interrupt is controlled by an interrupt request bit, an interrupt
enable bit, and the interrupt disable flag except for the software interrupt set by the BRK instruction. An interrupt occurs if the
corresponding interrupt request and enable bits are “1” and the interrupt disable flag is “0”.
Interrupt enable bits can be set or cleared by software.
Interrupt request bits can be cleared by software, but cannot be
set by software.
The BRK instruction cannot be disabled with any flag or bit. The I
(interrupt disable) flag disables all interrupts except the BRK instruction interrupt.
When several interrupts occur at the same time, the interrupts are
received according to priority.
Interrupt Operation
By acceptance of an interrupt, the following operations are automatically performed:
1. The contents of the program counter and the processor status
register are automatically pushed onto the stack.
2. The interrupt disable flag is set and the corresponding interrupt
request bit is cleared.
3. The interrupt jump destination address is read from the vector
table into the program counter.
Rev.1.01
Jul 01, 2003
page 17 of 89
7516 Group
Table 6 Interrupt vector addresses and priority
Vector Addresses (Note 1)
Interrupt Source
Priority
High
Low
1
FFFD16
FFFC16
Reset (Note 2)
Interrupt Request
Generating Conditions
Remarks
At reset
Non-maskable
INT0
2
FFFB16
FFFA16
At detection of either rising or
falling edge of INT0 input
External interrupt
(active edge selectable)
SCL, SDA
3
FFF916
FFF816
At detection of either rising or
falling edge of SCL or SDA input
External interrupt
(active edge selectable)
INT1
4
FFF716
FFF616
At detection of either rising or
falling edge of INT1 input
External interrupt
(active edge selectable)
INT2
5
FFF516
FFF416
At detection of either rising or
falling edge of INT2 input
External interrupt
(active edge selectable)
At detection of either rising or
falling edge of INT3 input
At completion of serial I/O2 data
reception/transmission
External interrupt
(active edge selectable)
Switch by Serial I/O2/INT3
interrupt source bit
At completion of data transfer
At timer X underflow
At timer Y underflow
At timer 1 underflow
STP release timer underflow
INT3
6
FFF316
7
8
9
FFF116
FFF016
FFEF16
FFED16
10
11
FFEB16
FFE916
FFEE16
FFEC16
FFEA16
FFE816
Serial I/O1
reception
12
FFE716
FFE616
At completion of serial I/O1 data
reception
Valid when serial I/O1 is selected
Serial I/O1
transmission
13
FFE516
FFE416
At completion of serial I/O1
transfer shift or when transmission buffer is empty
Valid when serial I/O1 is selected
CNTR0
14
FFE316
FFE216
At detection of either rising or
falling edge of CNTR0 input
External interrupt
(active edge selectable)
CNTR1
15
FFE116
FFE016
At detection of either rising or
falling edge of CNTR1 input
External interrupt
(active edge selectable)
A-D converter
BRK instruction
16
17
FFDF16
FFDD16
FFDE16
FFDC16
At completion of A-D conversion
At BRK instruction execution
Non-maskable software interrupt
Serial I/O2
I 2C
Timer X
Timer Y
Timer 1
Timer 2
FFF216
At timer 2 underflow
Notes 1: Vector addresses contain interrupt jump destination addresses.
2: Reset function in the same way as an interrupt with the highest priority.
Rev.1.01
Jul 01, 2003
page 18 of 89
7516 Group
Interrupt request bit
Interrupt enable bit
Interrupt disable flag (I)
BRK instruction
Reset
Interrupt request
Fig. 13 Interrupt control
b7
b0
Interrupt edge selection register
(INTEDGE : address 003A16)
INT0 active edge selection bit
INT1 active edge selection bit
0 : Falling edge active
1 : Rising edge active
INT2 active edge selection bit
INT3 active edge selection bit
Serial I/O2 / INT3 interrupt source bit
0 : INT3 interrupt selected
1 : Serial I/O2 interrupt selected
Not used (returns “0” when read)
b7
b0 Interrupt request register 1
(IREQ1 : address 003C16)
b7
b0 Interrupt request register 2
(IREQ2 : address 003D16)
Timer 1 interrupt request bit
Timer 2 interrupt request bit
Serial I/O1 reception interrupt request bit
Serial I/O1 transmit interrupt request bit
CNTR0 interrupt request bit
CNTR1 interrupt request bit
AD converter interrupt request bit
Not used (returns “0” when read)
INT0 interrupt request bit
SCL/SDA interrupt request bit
INT1 interrupt request bit
INT2 interrupt request bit
INT3 / Serial I/O2 interrupt request bit
I2C interrupt request bit
Timer X interrupt request bit
Timer Y interrupt request bit
0 : No interrupt request issued
1 : Interrupt request issued
0 : No interrupt request issued
1 : Interrupt request issued
b7
b0
b7
Interrupt control register 1
(ICON1 : address 003E16)
INT0 interrupt enable bit
SCL/SDA interrupt enable bit
INT1 interrupt enable bit
INT2 interrupt enable bit
INT3 / Serial I/O2 interrupt enable bit
I2C interrupt enable bit
Timer X interrupt enable bit
Timer Y interrupt enable bit
0 : Interrupts disabled
1 : Interrupts enabled
Fig. 14 Structure of interrupt-related registers
Rev.1.01
Jul 01, 2003
page 19 of 89
b0
Interrupt control register 2
(ICON2 : address 003F16)
Timer 1 interrupt enable bit
Timer 2 interrupt enable bit
Serial I/O1 reception interrupt enable bit
Serial I/O1 transmit interrupt enable bit
CNTR0 interrupt enable bit
CNTR1 interrupt enable bit
AD converter interrupt enable bit
Not used (returns “0” when read)
(Do not write “1” to this bit.)
0 : Interrupts disabled
1 : Interrupts enabled
7516 Group
TIMERS
Timer X and Timer Y
The 7516 group has four timers: timer X, timer Y, timer 1, and
timer 2.
The division ratio of each timer or prescaler is given by 1/(n + 1),
where n is the value in the corresponding timer or prescaler latch.
All timers are count down. When the timer reaches “0016”, an underflow occurs at the next count pulse and the corresponding
timer latch is reloaded into the timer and the count is continued.
When a timer underflows, the interrupt request bit corresponding
to that timer is set to “1”.
Timer X and Timer Y can each select in one of four operating
modes by setting the timer XY mode register.
b0
b7
Timer XY mode register
(TM : address 002316)
Timer X operating mode bits
b1b0
0 0: Timer mode
0 1: Pulse output mode
1 0: Event counter mode
1 1: Pulse width measurement mode
CNTR0 active edge selection bit
0: Interrupt at falling edge
Count at rising edge in event
counter mode
1: Interrupt at rising edge
Count at falling edge in event
counter mode
Timer X count stop bit
0: Count start
1: Count stop
Timer Y operating mode bits
b5b4
0 0: Timer mode
0 1: Pulse output mode
1 0: Event counter mode
1 1: Pulse width measurement mode
CNTR1 active edge selection bit
0: Interrupt at falling edge
Count at rising edge in event
counter mode
1: Interrupt at rising edge
Count at falling edge in event
counter mode
Timer Y count stop bit
0: Count start
1: Count stop
Fig. 15 Structure of timer XY mode register
Timer count source selection register
(TCSS : address 002816)
Timer X count source selection bit
0 : f(XIN)/16 (f(XCIN)/16 at low-speed mode)
1 : f(XIN)/2 (f(XCIN)/2 at low-speed mode)
Timer Y count source selection bit
0 : f(XIN)/16 (f(XCIN)/16 at low-speed mode)
1 : f(XIN)/2 (f(XCIN)/2 at low-speed mode)
Timer 12 count source selection bit
0 : f(XIN)/16 (f(XCIN)/16 at low-speed mode)
1 : f(XCIN)
Not used (returns “0” when read)
Fig. 16 Structure of timer count source selection register
Timer 1 and Timer 2
The count source of prescaler 12 is the oscillation frequency
which is selected by timer 12 count source selection bit. The output of prescaler 12 is counted by timer 1 and timer 2, and a timer
underflow sets the interrupt request bit.
Rev.1.01
Jul 01, 2003
The timer counts the count source selected by Timer count source
selection bit.
(2) Pulse Output Mode
The timer counts the count source selected by Timer count source
selection bit. Whenever the contents of the timer reach “0016”, the
signal output from the CNTR0 (or CNTR1) pin is inverted. If the
CNTR0 (or CNTR1) active edge selection bit is “0”, output begins
at “ H”.
If it is “1”, output starts at “L”. When using a timer in this mode, set
the corresponding port P27 ( or port P40) direction register to output mode.
(3) Event Counter Mode
Operation in event counter mode is the same as in timer mode,
except that the timer counts signals input through the CNTR0 or
CNTR1 pin.
When the CNTR0 (or CNTR1) active edge selection bit is “0”, the
rising edge of the CNTR0 (or CNTR1) pin is counted.
When the CNTR0 (or CNTR1) active edge selection bit is “1”, the
falling edge of the CNTR0 (or CNTR1) pin is counted.
(4) Pulse Width Measurement Mode
If the CNTR0 (or CNTR1) active edge selection bit is “0”, the timer
counts the selected signals by the count source selection bit while
the CNTR0 (or CNTR1) pin is at “H”. If the CNTR0 (or CNTR1) active edge selection bit is “1”, the timer counts it while the CNTR0
(or CNTR1) pin is at “L”.
The count can be stopped by setting “1” to the timer X (or timer Y)
count stop bit in any mode. The corresponding interrupt request
bit is set each time a timer underflows.
■Note
b0
b7
(1) Timer Mode
page 20 of 89
When switching the count source by the timer 12, X and Y count
source bits, the value of timer count is altered in unconsiderable
amount owing to generating of a thin pulses in the count input
signals.
Therefore, select the timer count source before set the value to
the prescaler and the timer.
When timer X/timer Y underflow while executing the instruction
which sets “1” to the timer X/timer Y count stop bits, the timer X/
timer Y interrupt request bits are set to “1”. Timer X/Timer Y interrupts are received if these interrupts are enabled at this time.
The timing which interrupt is accepted has a case after the instruction which sets “1” to the count stop bit, and a case after
the next instruction according to the timing of the timer underflow. When this interrupt is unnecessary, set “0” (disabled) to the
interrupt enable bit and then set “1” to the count stop bit.
7516 Group
Data bus
f(XIN)/16
(f(XCIN)/16 at low-speed mode)
Prescaler X latch (8)
f(XIN)/2
Pulse width
(f(XCIN)/2 at low-speed mode)
Timer X count source selection bit measurement
mode
Timer mode
Pulse output mode
Prescaler X (8)
CNTR0 active edge
selection bit
“0 ”
P27/CNTR0/SRDY1
Event
counter
mode
“1 ”
Timer X (8)
To timer X interrupt
request bit
Timer X count stop bit
To CNTR0 interrupt
request bit
CNTR0 active
edge selection “1”
bit
“0”
Q
Toggle flip-flop T
Q
R
Timer X latch write pulse
Pulse output mode
Port P27
latch
Port P27
direction register
Timer X latch (8)
Pulse output mode
Data bus
f(XIN)/16
(f(XCIN)/16 at low-speed mode)
Prescaler Y latch (8)
f(XIN)/2
(f(XCIN)/2 at low-speed mode)
Timer Y count source selection bit
Pulse width
measurement mode
Timer mode
Pulse output mode
Prescaler Y (8)
CNTR1 active edge
selection bit
“0”
P40/CNTR1
Event
counter
mode
“1 ”
Port P40
direction register
Timer Y (8)
To timer Y interrupt
request bit
Timer Y count stop bit
To CNTR1 interrupt
request bit
CNTR1 active
edge selection “1”
bit
Q
Toggle flip-flop T
Q
Port P40
latch
Timer Y latch (8)
“0”
R
Timer Y latch write pulse
Pulse output mode
Pulse output mode
Data bus
Prescaler 12 latch (8)
f(XIN)/16
(f(XCIN)/16 at low-speed mode)
f(XCIN)
Prescaler 12 (8)
Timer 1 latch (8)
Timer 2 latch (8)
Timer 1 (8)
Timer 2 (8)
To timer 2 interrupt
request bit
Timer 12 count source selection bit
To timer 1 interrupt
request bit
Fig. 17 Block diagram of timer X, timer Y, timer 1, and timer 2
Rev.1.01
Jul 01, 2003
page 21 of 89
7516 Group
SERIAL I/O
●SERIAL I/O1
(1) Clock Synchronous Serial I/O Mode
Clock synchronous serial I/O mode can be selected by setting the
serial I/O1 mode selection bit of the serial I/O1 control register (bit
6 of address 001A16) to “1”.
For clock synchronous serial I/O, the transmitter and the receiver
must use the same clock. If an internal clock is used, transfer is
started by a write signal to the TB/RB.
Serial I/O1 can be used as either clock synchronous or asynchronous (UART) serial I/O. A dedicated timer is also provided for
baud rate generation.
Data bus
Serial I/O1 control register
Address 001816
Receive buffer register
Receive buffer full flag (RBF)
Receive shift register
P24/RXD
Address 001A16
Receive interrupt request (RI)
Shift clock
Clock control circuit
P26/SCLK
XIN
Serial I/O1 synchronous
clock selection bit
Frequency division ratio 1/(n+1)
Baud rate generator
1/4
Address 001C16
BRG count source selection bit
1/4
P27/SRDY1
F/F
Clock control circuit
Falling-edge detector
Shift clock
P25/TXD
Transmit shift completion flag (TSC)
Transmit interrupt source selection bit
Transmit interrupt request (TI)
Transmit shift register
Transmit buffer register
Transmit buffer empty flag (TBE)
Serial I/O1 status register
Address 001916
Address 001816
Data bus
Fig. 18 Block diagram of clock synchronous serial I/O1
Transfer shift clock
(1/2 to 1/2048 of the internal
clock, or an external clock)
Serial output TxD
D0
D1
D2
D3
D4
D5
D6
D7
Serial input RxD
D0
D1
D2
D3
D4
D5
D6
D7
Receive enable signal SRDY1
Write pulse to receive/transmit
buffer register (address 001816)
TBE = 0
TBE = 1
TSC = 0
RBF = 1
TSC = 1
Overrun error (OE)
detection
Notes 1: As the transmit interrupt (TI), either when the transmit buffer has emptied (TBE=1) or after the transmit shift operation has
ended (TSC=1), by setting the transmit interrupt source selection bit (TIC) of the serial I/O1 control register.
2: If data is written to the transmit buffer register when TSC=0, the transmit clock is generated continuously and serial data
is output continuously from the TxD pin.
3: The receive interrupt (RI) is set when the receive buffer full flag (RBF) becomes “1” .
Fig. 19 Operation of clock synchronous serial I/O1 function
Rev.1.01
Jul 01, 2003
page 22 of 89
7516 Group
(2) Asynchronous Serial I/O (UART) Mode
two buffers have the same address in memory. Since the shift register cannot be written to or read from directly, transmit data is
written to the transmit buffer register, and receive data is read
from the receive buffer register.
The transmit buffer register can also hold the next data to be
transmitted, and the receive buffer register can hold a character
while the next character is being received.
Clock asynchronous serial I/O mode (UART) can be selected by
clearing the serial I/O1 mode selection bit (b6) of the serial I/O1
control register to “0”.
Eight serial data transfer formats can be selected, and the transfer
formats used by a transmitter and receiver must be identical.
The transmit and receive shift registers each have a buffer, but the
Data bus
Address 001816
P24/RXD
Serial I/O1 control register Address 001A16
Receive buffer full flag (RBF)
Receive interrupt request (RI)
OE
Receive buffer register
Character length selection bit
ST detector
7 bits
Receive shift register
1/16
8 bits
PE FE
SP detector
Clock control circuit
UART control register
Address 001B16
Serial I/O1 synchronous clock selection bit
P26/SCLK
XIN
BRG count source selection bit Frequency division ratio 1/(n+1)
Baud rate generator
Address 001C16
1/4
ST/SP/PA generator
1/16
Transmit shift register
P25/TXD
Transmit shift completion flag (TSC)
Transmit interrupt source selection bit
Transmit interrupt request (TI)
Character length selection bit
Transmit buffer register
Address 001816
Data bus
Fig. 20 Block diagram of UART serial I/O1
Rev.1.01
Jul 01, 2003
page 23 of 89
Transmit buffer empty flag (TBE)
Serial I/O1 status register Address 001916
7516 Group
Transmit or receive clock
Transmit buffer write
signal
TBE=0
TSC=0
TBE=1
Serial output TXD
TBE=0
TBE=1
ST
D0
D1
SP
TSC=1
ST
D0
1 start bit
7 or 8 data bit
1 or 0 parity bit
1 or 2 stop bit (s)
Receive buffer read
signal
SP
D1
Generated at 2nd bit in 2-stop-bit mode
RBF=0
RBF=1
Serial input RXD
ST
D0
D1
SP
RBF=1
ST
D0
D1
SP
Notes 1: Error flag detection occurs at the same time that the RBF flag becomes “1” (at 1st stop bit, during reception).
2: As the transmit interrupt (TI), when either the TBE or TSC flag becomes “1,” can be selected to occur depending on the setting of the transmit
interrupt source selection bit (TIC) of the serial I/O1 control register.
3: The receive interrupt (RI) is set when the RBF flag becomes “1.”
4: After data is written to the transmit buffer when TSC=1, 0.5 to 1.5 cycles of the data shift cycle is necessary until changing to TSC=0.
Fig. 21 Operation of UART serial I/O1 function
[Transmit Buffer Register/Receive Buffer
Register (TB/RB)] 001816
The transmit buffer register and the receive buffer register are located at the same address. The transmit buffer is write-only and
the receive buffer is read-only. If a character bit length is 7 bits, the
MSB of data stored in the receive buffer is “0”.
[Serial I/O1 Status Register (SIOSTS)] 001916
The read-only serial I/O1 status register consists of seven flags
(bits 0 to 6) which indicate the operating status of the serial I/O1
function and various errors.
Three of the flags (bits 4 to 6) are valid only in UART mode.
The receive buffer full flag (bit 1) is cleared to “0” when the receive
buffer register is read.
If there is an error, it is detected at the same time that data is
transferred from the receive shift register to the receive buffer register, and the receive buffer full flag is set. A write to the serial I/O1
status register clears all the error flags OE, PE, FE, and SE (bit 3
to bit 6, respectively). Writing “0” to the serial I/O1 enable bit SIOE
(bit 7 of the serial I/O1 control register) also clears all the status
flags, including the error flags.
Bits 0 to 6 of the serial I/O1 status register are initialized to “0” at
reset, but if the transmit enable bit (bit 4) of the serial I/O1 control
register has been set to “1”, the transmit shift completion flag (bit
2) and the transmit buffer empty flag (bit 0) become “1”.
Rev.1.01
Jul 01, 2003
page 24 of 89
[Serial I/O1 Control Register (SIOCON)] 001A16
The serial I/O1 control register consists of eight control bits for the
serial I/O1 function.
[UART Control Register (UARTCON)] 001B16
The UART control register consists of four control bits (bits 0 to 3)
which are valid when asynchronous serial I/O is selected and set
the data format of an data transfer and one bit (bit 4) which is always valid and sets the output structure of the P25/TXD pin.
[Baud Rate Generator (BRG)] 001C16
The baud rate generator determines the baud rate for serial transfer.
The baud rate generator divides the frequency of the count source
by 1/(n + 1), where n is the value written to the baud rate generator.
7516 Group
b7
b0
Serial I/O1 status register
(SIOSTS : address 001916)
b7
Transmit buffer empty flag (TBE)
0: Buffer full
1: Buffer empty
Receive buffer full flag (RBF)
0: Buffer empty
1: Buffer full
Transmit shift completion flag (TSC)
0: Transmit shift in progress
1: Transmit shift completed
Overrun error flag (OE)
0: No error
1: Overrun error
Parity error flag (PE)
0: No error
1: Parity error
Framing error flag (FE)
0: No error
1: Framing error
Summing error flag (SE)
0: (OE) U (PE) U (FE)=0
1: (OE) U (PE) U (FE)=1
Not used (returns “1” when read)
b7
b0
UART control register
(UARTCON : address 001B16)
Character length selection bit (CHAS)
0: 8 bits
1: 7 bits
Parity enable bit (PARE)
0: Parity checking disabled
1: Parity checking enabled
Parity selection bit (PARS)
0: Even parity
1: Odd parity
Stop bit length selection bit (STPS)
0: 1 stop bit
1: 2 stop bits
P25/TXD P-channel output disable bit (POFF)
0: CMOS output (in output mode)
1: N-channel open drain output (in output mode)
Not used (return “1” when read)
Fig. 22 Structure of serial I/O1 control registers
■Notes on serial I/O1
1. When using the serial I/O1, clear the I2C-BUS interface enable
bit to “0” or the SDA/SCL interrupt pin selection bit to “0”.
2. When setting the transmit enable bit of serial I/O1 to “1”, the
serial I/O1 transmit interrupt request bit is automatically set to
“1”. When not requiring the interrupt occurrence synchronized
with the transmission enalbed, take the following sequence.
➀Set the serial I/O1 transmit interrupt enable bit to “0” (disabled).
➁Set the transmit enable bit to “1”.
➂Set the serial I/O1 transmit interrupt request bit to “0” after 1
or more instructions have been executed.
➃Set the serial I/O1 transmit interrupt enable bit to “1” (enabled).
Rev.1.01
Jul 01, 2003
page 25 of 89
b0
Serial I/O1 control register
(SIOCON : address 001A16)
BRG count source selection bit (CSS)
0: f(XIN)
1: f(XIN)/4
Serial I/O1 synchronous clock selection bit (SCS)
0: BRG output divided by 4 when clock synchronous
serial I/O1 is selected, BRG output divided by 16
when UART is selected.
1: External clock input when clock synchronous serial
I/O1 is selected, external clock input divided by 16
when UART is selected.
SRDY1 output enable bit (SRDY)
0: P27 pin operates as ordinary I/O pin
1: P27 pin operates as SRDY1 output pin
Transmit interrupt source selection bit (TIC)
0: Interrupt when transmit buffer has emptied
1: Interrupt when transmit shift operation is completed
Transmit enable bit (TE)
0: Transmit disabled
1: Transmit enabled
Receive enable bit (RE)
0: Receive disabled
1: Receive enabled
Serial I/O1 mode selection bit (SIOM)
0: Clock asynchronous (UART) serial I/O
1: Clock synchronous serial I/O
Serial I/O1 enable bit (SIOE)
0: Serial I/O1 disabled
(pins P24 to P27 operate as ordinary I/O pins)
1: Serial I/O1 enabled
(pins P24 to P27 operate as serial I/O1 pins)
7516 Group
●SERIAL I/O2
The serial I/O2 can be operated only as the clock synchronous type.
As a synchronous clock for serial transfer, either internal clock or
external clock can be selected by the serial I/O2 synchronous clock
selection bit (b6) of serial I/O2 control register 1.
The internal clock incorporates a dedicated divider and permits selecting 6 types of clock by the internal synchronous clock selection
bits (b2, b1, b0) of serial I/O2 control register 1.
Regarding SOUT2 and SCLK2 being output pins, either CMOS output
format or N-channel open-drain output format can be selected by the
P0 1 /S OUT2 , P0 2 /S CLK2 P-channel output disable bit (b7) of
serial I/O2 control register 1.
When the internal clock has been selected, a transfer starts by a
write signal to the serial I/O2 register (address 001716). After completion of data transfer, the level of the SOUT2 pin goes to high impedance automatically but bit 7 of the serial I/O2 control register 2 is not
set to “1” automatically.
When the external clock has been selected, the contents of the serial
I/O2 register is continuously sifted while transfer clocks are input.
Accordingly, control the clock externally. Note that the SOUT2 pin does
not go to high impedance after completion of data transfer.
To cause the SOUT2 pin to go to high impedance in the case where
the external clock is selected, set bit 7 of the serial I/O2 control register 2 to “1” when SCLK2 is “H” after completion of data transfer. After
the next data transfer is started (the transfer clock falls), bit 7 of the
serial I/O2 control register 2 is set to “0” and the SOUT2 pin is put into
the active state.
Regardless of the internal clock to external clock, the interrupt request bit is set after the number of bits (1 to 8 bits) selected by the
optional transfer bit is transferred. In case of a fractional number of
bits less than 8 bits as the last data, the received data to be stored in
the serial I/O2 register becomes a fractional number of bits close to
MSB if the transfer direction selection bit of serial I/O2 control register 1 is LSB first, or a fractional number of bits close to LSB if the
transfer direction selection bit is MSB first. For the remaining bits, the
previously received data is shifted.
At transmit operation using the clock synchronous serial I/O, the SCMP2
signal can be output by comparing the state of the transmit pin SOUT2
with the state of the receive pin SIN2 in synchronization with a rise of
the transfer clock. If the output level of the SOUT2 pin is equal to the
input level to the SIN2 pin, “L” is output from the SCMP2 pin. If not, “H”
is output. At this time, an INT2 interrupt request can also be generated. Select a valid edge by bit 2 of the interrupt edge selection register (address 003A16).
[Serial I/O2 Control Registers 1, 2 (SIO2CON1 /
SIO2CON2)] 001516, 001616
The serial I/O2 control registers 1 and 2 are containing various selection bits for serial I/O2 control as shown in Figure 23.
Rev.1.01
Jul 01, 2003
page 26 of 89
b7
b0
Serial I/O2 control register 1
(SIO2CON1 : address 001516)
Internal synchronous clock selection bits
b2 b1 b0
0
0
0
0
1
1
0
0
1
1
1
1
0: f(XIN)/8 (f(XCIN)/8 in low-speed mode)
1: f(XIN)/16 (f(XCIN)/16 in low-speed mode)
0: f(XIN)/32 (f(XCIN)/32 in low-speed mode)
1: f(XIN)/64 (f(XCIN)/64 in low-speed mode)
0: f(XIN)/128 f(XCIN)/128 in low-speed mode)
1: f(XIN)/256 (f(XCIN)/256 in low-speed mode)
Serial I/O2 port selection bit
0: I/O port
1: SOUT2,SCLK2 output pin
SRDY2 output enable bit
0: P03 pin is normal I/O pin
1: P03 pin is SRDY2 output pin
Transfer direction selection bit
0: LSB first
1: MSB first
Serial I/O2 synchronous clock selection bit
0: External clock
1: Internal clock
P01/SOUT2 ,P02/SCLK2 P-channel output disable bit
0: CMOS output (in output mode)
1: N-channel open-drain output (in output mode )
b7
b0
Serial I/O2 control register 2
(SIO2CON2 : address 001616)
Optional transfer bits
b2 b1 b0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0: 1 bit
1: 2 bit
0: 3 bit
1: 4 bit
0: 5 bit
1: 6 bit
0: 7 bit
1: 8 bit
Not used ( returns "0" when read)
Serial I/O2 I/O comparison signal control bit
0: P43 I/O
1: SCMP2 output
SOUT2 pin control bit (P01)
0: Output active
1: Output high-impedance
Fig. 23 Structure of Serial I/O2 control registers 1, 2
7516 Group
Internal synchronous
clock selection bits
1/8
XCIN
“00”
“01”
XIN
1/16
1/32
Divider
“10”
Main clock division ratio
selection bits (Note)
Data bus
1/64
1/128
1/256
P03 latch
Serial I/O2 synchronous
clock selection bit
“0”
P03/SRDY2
SCLK2
SRDY2
Synchronous circuit
“1”
SRDY2 output enable bit
“1”
“0”
External clock
P02 latch
Optional transfer bits (3)
“0”
P02/SCLK2
Serial I/O2
interrupt request
Serial I/O counter 2 (3)
“1”
Serial I/O2 port selection bit
P01 latch
“0”
P01/SOUT2
“1”
Serial I/O2 port selection bit
Serial I/O2 register (8)
P00/SIN2
P43 latch
“0”
D
P43/SCMP2/INT2
Q
“1”
Serial I/O2 I/O comparison
signal control bit
Note: Either high-speed, middle-speed or low-speed mode is selected by bits 6 and 7 of CPU mode register.
Fig. 24 Block diagram of Serial I/O2
Transfer clock (Note 1)
Write-in signal to
serial I/O2 register
(Note 2)
Serial I/O2 output SOUT2
D0
D1
.
D2
D3
D4
D5
D6
D7
Serial I/O2 input SIN2
Receive enable signal SRDY2
Serial I/O2 interrupt request bit set
Notes 1: When the internal clock is selected as a transfer clock, the f(XIN) clock division (f(XCIN) in low-speed mode) can be selected
by setting bits 0 to 2 of serial I/O2 control register 1.
2: When the internal clock is selected as a transfer clock, the SOUT2 pin has high impedance after transfer completion.
Fig. 25 Timing chart of Serial I/O2
Rev.1.01
Jul 01, 2003
page 27 of 89
7516 Group
SCMP2
SCLK2
SOUT2
SIN2
Judgement of I/O data comparison
Fig. 26 SCMP2 output operation
Rev.1.01
Jul 01, 2003
page 28 of 89
7516 Group
MULTI-MASTER I2C-BUS INTERFACE
Table 7 Multi-master I2C-BUS interface functions
The multi-master I2C-BUS interface is a serial communications circuit, conforming to the Philips I2C-BUS data transfer format. This
interface, offering both arbitration lost detection and a synchronous functions, is useful for the multi-master serial
communications.
Figure 27 shows a block diagram of the multi-master I2C-BUS interface and Table 7 lists the multi-master I 2 C-BUS interface
functions.
This multi-master I2C-BUS interface consists of the I2C address
register, the I 2C data shift register, the I2C clock control register,
the I2C control register, the I2C status register, the I2C start/stop
condition control register and other control circuits.
When using the multi-master I 2 C-BUS interface, set 1 MHz or
more to φ.
Item
Format
Communication mode
SCL clock frequency
Function
In conformity with Philips I2C-BUS
standard:
10-bit addressing format
7-bit addressing format
High-speed clock mode
Standard clock mode
In conformity with Philips I2C-BUS
standard:
Master transmission
Master reception
Slave transmission
Slave reception
16.1 kHz to 400 kHz (at φ = 4 MHz)
System clock φ = f(XIN)/2 (high-speed mode)
φ = f(XIN)/8 (middle-speed mode)
Note: Mitsubishi Electric Corporation assumes no responsibility for infringement of any third-party’s rights or originating in the use of the
connection control function between the I2C-BUS interface and the
ports SCL1, SCL2, SDA1 and SDA2 with the bit 6 of I2C control register (002E16).
b7
I2C address register
SA D6 SA D5 SAD4 SAD3 SAD2 SAD1 SA D0
b0
Interrupt
generating
circuit
RWB
S0D
Interrupt request signal
(IICIRQ)
Address comparator
Serial data
(SDA)
Noise
elimination
circuit
Data
control
circuit
b0
b7
I2C data shift register
b7
b0
S0
AL AAS AD0 LRB
MST TRX BB PIN
SIS SIP SSC4 SSC3 SSC2 SSC1 SSC0
S2D
AL
circuit
S1
I2C status register
I2C start/stop condition
control register
Internal data bus
BB
circuit
Serial
clock
(SCL)
Noise
elimination
circuit
Clock
control
circuit
b7
b0
FAST CCR4 CCR3 CCR2 CCR1 CCR0
ACK ACK MODE
BIT
S2
I2C clock control register
Clock division
I2C clock control register
S1D
b0
b7
TISS
10BIT
TSEL SAD
ALS ES0 BC2 BC1 BC0
S1D I 2 C control register
System clock (φ)
Bit counter
Fig. 27 Block diagram of multi-master I2C-BUS interface
✽ : Purchase of MITSUBISHI ELECTRIC CORPORATIONS I2C components conveys a license under the Philips I2C Patent Rights to use these components
an I2C system, provided that the system conforms to the I2C Standard Specification as defined by Philips.
Rev.1.01
Jul 01, 2003
page 29 of 89
7516 Group
[I2C Data Shift Register (S0)] 002B16
The I2C data shift register (S0 : address 002B16) is an 8-bit shift
register to store receive data and write transmit data.
When transmit data is written into this register, it is transferred to
the outside from bit 7 in synchronization with the SCL clock, and
each time one-bit data is output, the data of this register are
shifted by one bit to the left. When data is received, it is input to
this register from bit 0 in synchronization with the SCL clock, and
each time one-bit data is input, the data of this register are shifted
by one bit to the left. The minimum 2 machine cycles are required
from the rising of the SCL clock until input to this register.
The I2C data shift register is in a write enable status only when the
I2C-BUS interface enable bit (ES0 bit : bit 3 of address 002E16) of
the I2C control register is “1”. The bit counter is reset by a write instruction to the I2C data shift register. When both the ES0 bit and
the MST bit of the I2C status register (address 002D16) are “1,” the
SCL is output by a write instruction to the I2C data shift register.
Reading data from the I2C data shift register is always enabled regardless of the ES0 bit value.
[I2C Address Register (S0D)] 002C16
The I 2C address register (address 002C 16) consists of a 7-bit
slave address and a read/write bit. In the addressing mode, the
slave address written in this register is compared with the address
data to be received immediately after the START condition is detected.
•Bit 0: Read/write bit (RWB)
This is not used in the 7-bit addressing mode. In the 10-bit addressing mode, the first address data to be received is compared
with the contents (SAD6 to SAD0 + RWB) of the I2C address register.
The RWB bit is cleared to “0” automatically when the stop condition is detected.
•Bits 1 to 7: Slave address (SAD0–SAD6)
These bits store slave addresses. Regardless of the 7-bit addressing mode and the 10-bit addressing mode, the address data
transmitted from the master is compared with the contents of
these bits.
Rev.1.01
Jul 01, 2003
page 30 of 89
b7
b0
SAD6 SAD5 SAD4 SAD3 SAD2 SAD1 SAD0 RWB
I2C address register
(S0D: address 002C16)
Read/write bit
Slave address
Fig. 28 Structure of I2C address register
7516 Group
Note: Do not write data into the I2C clock control register during transfer. If
data is written during transfer, the I 2C clock generator is reset, so
that data cannot be transferred normally.
Rev.1.01
Jul 01, 2003
page 31 of 89
b0
A CK F AST
CCR4 CCR3 CCR2 CCR1 CCR0
B IT MODE
I2C clock control register
(S2 : address 002F16)
SCL frequency control bits
Refer to Table 8.
SCL mode specification bit
0 : Standard clock mode
1 : High-speed clock
d
ACK bit
0 : ACK is returned.
1 : ACK is not
t
d
ACK clock bit
0 : No ACK clock
1 : ACK clock
Fig. 29 Structure of I2C clock control register
Table 8 Set values of I 2 C clock control register and SCL
frequency
Setting value of
CCR4–CCR0
CCR4 CCR3 CCR2 CCR1 CCR0
SCL frequency (Note 1)
(at φ = 4 MHz, unit : kHz)
Standard clock High-speed clock
mode
mode
0
0
0
0
0
Setting disabled
Setting disabled
0
0
0
0
1
Setting disabled
Setting disabled
Setting disabled
333
0
0
1
0
0
0
0
1
1
– (Note 2)
0
0
1
0
0
– (Note 2)
250
0
0
1
0
1
100
400 (Note 3)
0
0
1
1
0
83.3
166
…
0
Setting disabled
…
•Bit 7: ACK clock bit (ACK)
This bit specifies the mode of acknowledgment which is an acknowledgment response of data transfer. When this bit is set to
“0,” the no ACK clock mode is selected. In this case, no ACK clock
occurs after data transmission. When the bit is set to “1,” the ACK
clock mode is selected and the master generates an ACK clock
each completion of each 1-byte data transfer. The device for
transmitting address data and control data releases the SDA at
the occurrence of an ACK clock (makes SDA “H”) and receives the
ACK bit generated by the data receiving device.
A CK
…
✽ACK clock: Clock for acknowledgment
b7
…
The I2C clock control register (address 002F16) is used to set ACK
control, SCL mode and SCL frequency.
•Bits 0 to 4: SCL frequency control bits (CCR0–CCR4)
These bits control the SCL frequency. Refer to Table 8.
•Bit 5: SCL mode specification bit (FAST MODE)
This bit specifies the SCL mode. When this bit is set to “0,” the
standard clock mode is selected. When the bit is set to “1,” the
high-speed clock mode is selected.
When connecting the bus of the high-speed mode I2C bus standard (maximum 400 kbits/s), use 8 MHz or more oscillation
frequency f(XIN) and 2 division clock.
•Bit 6: ACK bit (ACK BIT)
This bit sets the SDA status when an ACK clock✽ is generated.
When this bit is set to “0,” the ACK return mode is selected and
SDA goes to “L” at the occurrence of an ACK clock. When the bit
is set to “1,” the ACK non-return mode is selected. The SDA is
held in the “H” status at the occurrence of an ACK clock.
However, when the slave address agree with the address data in
the reception of address data at ACK BIT = “0,” the SDA is automatically made “L” (ACK is returned). If there is a disagreement
between the slave address and the address data, the SDA is automatically made “H” (ACK is not returned).
…
[I2C Clock Control Register (S2)] 002F16
500/CCR value
(Note 3)
1
1
1
0
1
17.2
1000/CCR value
(Note 3)
34.5
1
1
1
1
0
16.6
33.3
1
1
1
1
1
16.1
32.3
Notes 1: Duty of SCL clock output is 50 %. The duty becomes 35 to 45 %
only when the high-speed clock mode is selected and CCR value
= 5 (400 kHz, at φ = 4 MHz). “H” duration of the clock fluctuates
from –4 to +2 machine cycles in the standard clock mode, and
fluctuates from –2 to +2 machine cycles in the high-speed clock
mode. In the case of negative fluctuation, the frequency does not
increase because “L” duration is extended instead of “H” duration
reduction.
These are value when SCL clock synchronization by the synchronous function is not performed. CCR value is the decimal
notation value of the SCL frequency control bits CCR4 to CCR0.
2: Each value of SCL frequency exceeds the limit at φ = 4 MHz or
more. When using these setting value, use φ of 4 MHz or less.
3: The data formula of SCL frequency is described below:
φ/(8 ✕ CCR value) Standard clock mode
φ/(4 ✕ CCR value) High-speed clock mode (CCR value ≠ 5)
φ/(2 ✕ CCR value) High-speed clock mode (CCR value = 5)
Do not set 0 to 2 as CCR value regardless of φ frequency.
Set 100 kHz (max.) in the standard clock mode and 400 kHz
(max.) in the high-speed clock mode to the SCL frequency by setting the SCL frequency control bits CCR4 to CCR0.
7516 Group
[I2C Control Register (S1D)] 002E16
The I2C control register (address 002E16) controls data communication format.
•Bits 0 to 2: Bit counter (BC0–BC2)
These bits decide the number of bits for the next 1-byte data to be
transmitted. The I 2C interrupt request signal occurs immediately
after the number of count specified with these bits (ACK clock is
added to the number of count when ACK clock is selected by ACK
clock bit (bit 7 of address 002F16 )) have been transferred, and
BC0 to BC2 are returned to “0002”.
Also when a START condition is received, these bits become
“0002” and the address data is always transmitted and received in
8 bits.
•Bit 3: I2C interface enable bit (ES0)
This bit enables to use the multi-master I2C-BUS interface. When
this bit is set to “0,” the use disable status is provided, so that the
SDA and the SCL become high-impedance. When the bit is set to
“1,” use of the interface is enabled.
When ES0 = “0,” the following is performed.
• PIN = “1,” BB = “0” and AL = “0” are set (which are bits of the I2C
status register at address 002D16 ).
• Writing data to the I2C data shift register (address 002B16) is disabled.
•Bit 4: Data format selection bit (ALS)
This bit decides whether or not to recognize slave addresses.
When this bit is set to “0,” the addressing format is selected, so
that address data is recognized. When a match is found between a
slave address and address data as a result of comparison or when
a general call (refer to “I2C Status Register,” bit 1) is received,
transfer processing can be performed. When this bit is set to “1,”
the free data format is selected, so that slave addresses are not
recognized.
•Bit 5: Addressing format selection bit (10BIT SAD)
This bit selects a slave address specification format. When this bit
is set to “0,” the 7-bit addressing format is selected. In this case,
only the high-order 7 bits (slave address) of the I2C address register (address 002C16) are compared with address data. When this
bit is set to “1,” the 10-bit addressing format is selected, and all
the bits of the I2C address register are compared with address
data.
•Bit 6: SDA/SCL pin selection bit
This bit selects the input/output pins of SCL and SDA of the multimaster I2C-BUS interface.
•Bit 7: I2C-BUS interface pin input level selection bit
This bit selects the input level of the SCL and SDA pins of the
multi-master I2C-BUS interface.
TSEL
SCL1/P23
SCL
SCL2/TxD/P25
Multi-master
I2C-BUS interface
TSEL
TSEL
SDA1/P22
SDA
SDA2/RxD/P24
TSEL
Fig. 30 SDA/SCL pin selection bit
b7
TISS TSEL
b0
10 BIT
SAD
I2C control register
ALS ES0 BC2 BC1 BC0
(S1D : address 002E 16)
Bit counter (Number of
transmit/receive bits)
b2 b1 b0
0 0 0 : 8
0 0 1 : 7
0 1 0 : 6
0 1 1 : 5
1 0 0 : 4
1 0 1 : 3
1 1 0 : 2
1 1 1 : 1
I2C-BUS interface
enable bit
0 : Disabled
1 : Enabled
Data format selection bit
0 : Addressing format
1 : Free data format
Addressing format
selection bit
0 : 7-bit addressing
format
1 : 10-bit addressing
format
SDA/SCL pin selection bit
0 : Connect to ports P2 2, P23
1 : Connect to ports P2 4, P25
I2C-BUS interface pin input
level selection bit
0 : CMOS input
1 : SMBUS input
Fig. 31 Structure of I2C control register
Rev.1.01
Jul 01, 2003
page 32 of 89
7516 Group
[I2C Status Register (S1)] 002D16
The I2C status register (address 002D16) controls the I2C-BUS interface status. The low-order 4 bits are read-only bits and the
high-order 4 bits can be read out and written to.
Set “00002” to the low-order 4 bits, because these bits become the
reserved bits at writing.
•Bit 0: Last receive bit (LRB)
This bit stores the last bit value of received data and can also be
used for ACK receive confirmation. If ACK is returned when an
ACK clock occurs, the LRB bit is set to “0.” If ACK is not returned,
this bit is set to “1.” Except in the ACK mode, the last bit value of
received data is input. The state of this bit is changed from “1” to
“0” by executing a write instruction to the I2C data shift register
(address 002B16).
•Bit 1: General call detecting flag (AD0)
When the ALS bit is “0”, this bit is set to “1” when a general call✽
whose address data is all “0” is received in the slave mode. By a
general call of the master device, every slave device receives control data after the general call. The AD0 bit is set to “0” by
detecting the STOP condition or START condition, or reset.
✽General call: The master transmits the general call address “0016 ” to all
slaves.
•Bit 2: Slave address comparison flag (AAS)
This flag indicates a comparison result of address data when the
ALS bit is “0”.
➀ In the slave receive mode, when the 7-bit addressing format is
selected, this bit is set to “1” in one of the following conditions:
• The address data immediately after occurrence of a START
condition agrees with the slave address stored in the high-order 7 bits of the I2C address register (address 002C16).
• A general call is received.
➁ In the slave receive mode, when the 10-bit addressing format is
selected, this bit is set to “1” with the following condition:
• When the address data is compared with the I2C address register (8 bits consisting of slave address and RWB bit), the first
bytes agree.
➂ This bit is set to “0” by executing a write instruction to the I 2C
data shift register (address 002B16) when ES0 is set to “1” or
reset.
•Bit 3: Arbitration lost✽ detecting flag (AL)
In the master transmission mode, when the SDA is made “L” by
any other device, arbitration is judged to have been lost, so that
this bit is set to “1.” At the same time, the TRX bit is set to “0,” so
that immediately after transmission of the byte whose arbitration
was lost is completed, the MST bit is set to “0.” The arbitration lost
can be detected only in the master transmission mode. When arbitration is lost during slave address transmission, the TRX bit is
set to “0” and the reception mode is set. Consequently, it becomes
possible to detect the agreement of its own slave address and address data transmitted by another master device.
✽Arbitration lost :The status in which communication as a master is disabled.
Rev.1.01
Jul 01, 2003
page 33 of 89
•Bit 4: SCL pin low hold bit (PIN)
This bit generates an interrupt request signal. Each time 1-byte
data is transmitted, the PIN bit changes from “1” to “0.” At the
same time, an interrupt request signal occurs to the CPU. The PIN
bit is set to “0” in synchronization with a falling of the last clock (including the ACK clock) of an internal clock and an interrupt
request signal occurs in synchronization with a falling of the PIN
bit. When the PIN bit is “0,” the SCL is kept in the “0” state and
clock generation is disabled. Figure 33 shows an interrupt request
signal generating timing chart.
The PIN bit is set to “1” in one of the following conditions:
• Executing a write instruction to the I2 C data shift register (address 002B16). (This is the only condition which the prohibition of
the internal clock is released and data can be communicated except for the start condition detection.)
• When the ES0 bit is “0”
• At reset
• When writing “1” to the PIN bit by software
The conditions in which the PIN bit is set to “0” are shown below:
• Immediately after completion of 1-byte data transmission (including when arbitration lost is detected)
• Immediately after completion of 1-byte data reception
• In the slave reception mode, with ALS = “0” and immediately after completion of slave address agreement or general call
address reception
• In the slave reception mode, with ALS = “1” and immediately after completion of address data reception
•Bit 5: Bus busy flag (BB)
This bit indicates the status of use of the bus system. When this
bit is set to “0,” this bus system is not busy and a START condition
can be generated. The BB flag is set/reset by the SCL, SDA pins
input signal regardless of master/slave. This flag is set to “1” by
detecting the start condition, and is set to “0” by detecting the stop
condition. The condition of these detecting is set by the start/stop
condition setting bits (SSC4–SSC0) of the I2C start/stop condition
control register (address 003016). When the ES0 bit of the I 2C
control register (address 002E16) is “0” or reset, the BB flag is set
to “0.”
For the writing function to the BB flag, refer to the sections
“START Condition Generating Method” and “STOP Condition Generating Method” described later.
7516 Group
•Bit 6: Communication mode specification bit (transfer direction specification bit: TRX)
This bit decides a direction of transfer for data communication.
When this bit is “0,” the reception mode is selected and the data of
a transmitting device is received. When the bit is “1,” the transmission mode is selected and address data and control data are
output onto the SDA in synchronization with the clock generated
on the SCL.
This bit is set/reset by software and hardware. About set/reset by
hardware is described below. This bit is set to “1” by hardware
when all the following conditions are satisfied:
• When ALS is “0”
• In the slave reception mode or the slave transmission mode
• When the R/W bit reception is “1”
This bit is set to “0” in one of the following conditions:
• When arbitration lost is detected.
• When a STOP condition is detected.
• When writing “1” to this bit by software is invalid by the START
condition duplication preventing function (Note).
• With MST = “0” and when a START condition is detected.
• With MST = “0” and when ACK non-return is detected.
• At reset
•Bit 7: Communication mode specification bit (master/slave
specification bit: MST)
This bit is used for master/slave specification for data communication. When this bit is “0,” the slave is specified, so that a START
condition and a STOP condition generated by the master are received, and data communication is performed in synchronization
with the clock generated by the master. When this bit is “1,” the
master is specified and a START condition and a STOP condition
are generated. Additionally, the clocks required for data communication are generated on the SCL.
This bit is set to “0” in one of the following conditions.
• Immediately after completion of 1-byte data transfer when arbitration lost is detected
• When a STOP condition is detected.
• Writing “1” to this bit by software is invalid by the START condition duplication preventing function (Note).
• At reset
Note: START condition duplication preventing function
The MST, TRX, and BB bits is set to “1” at the same time after confirming that the BB flag is “0” in the procedure of a START condition
occurrence. However, when a START condition by another master
device occurs and the BB flag is set to “1” immediately after the contents of the BB flag is confirmed, the START condition duplication
preventing function makes the writing to the MST and TRX bits invalid. The duplication preventing function becomes valid from the
rising of the BB flag to reception completion of slave address.
b7
b0
MST TRX BB PIN AL AAS AD0 LRB
I2C status register
(S1 : address 002D16)
Last receive bit (Note)
0 : Last bit = “0”
1 : Last bit = “1”
General call detecting flag
(Note)
0 : No general call detected
1 : General call detected
Slave address comparison flag
(Note)
0 : Address disagreement
1 : Address agreement
Arbitration lost detecting flag
(Note)
0 : Not detected
1 : Detected
SCL pin low hold bit
0 : SCL pin low hold
1 : SCL pin low release
Bus busy flag
0 : Bus free
1 : Bus busy
Communication mode
specification bits
00 : Slave receive mode
01 : Slave transmit mode
10 : Master receive mode
11 : Master transmit mode
Note: These bits and flags can be read out, but cannot
be written.
Write “0” to these bits at writing.
Fig. 32 Structure of I2C status register
SCL
PIN
IICIRQ
Fig. 33 Interrupt request signal generating timing
Rev.1.01
Jul 01, 2003
page 34 of 89
7516 Group
START Condition Generating Method
START/STOP Condition Detecting Operation
When writing “1” to the MST, TRX, and BB bits of the I2C status
register (address 002D16) at the same time after writing the slave
address to the I2 C data shift register (address 002B16) with the
condition in which the ES0 bit of the I2C control register (address
002E16) and the BB flag are “0”, a START condition occurs. After
that, the bit counter becomes “0002” and an SCL for 1 byte is output. The START condition generating timing is different in the
standard clock mode and the high-speed clock mode. Refer to
Figure 34, the START condition generating timing diagram, and
Table 9, the START condition generating timing table.
The START/STOP condition detection operations are shown in
Figures 36, 37, and Table 11. The START/STOP condition is set
by the START/STOP condition set bit.
The START/STOP condition can be detected only when the input
signal of the SCL and SDA pins satisfy three conditions: SCL release time, setup time, and hold time (see Table 11).
The BB flag is set to “1” by detecting the START condition and is
reset to “0” by detecting the STOP condition.
The BB flag set/reset timing is different in the standard clock mode
and the high-speed clock mode. Refer to Table 11, the BB flag set/
reset time.
Note: When a STOP condition is detected in the slave mode (MST = 0), an
interrupt request signal “IICIRQ” occurs to the CPU.
I2C status register
write signal
SC L
Setup
time
SD A
SCL release time
Hold time
SCL
SDA
Fig. 34 START condition generating timing diagram
Table 9 START condition generating timing table
Standard clock mode High-speed clock mode
Item
5.0 µs (20 cycles)
2.5 µs (10 cycles)
Setup time
5.0 µs (20 cycles)
2.5 µs (10 cycles)
Hold time
Note: Absolute time at φ = 4 MHz. The value in parentheses denotes the
number of φ cycles.
STOP Condition Generating Method
When the ES0 bit of the I2C control register (address 002E16) is
“1,” write “1” to the MST and TRX bits, and write “0” to the BB bit
of the I2C status register (address 002D16) simultaneously. Then a
STOP condition occurs. The STOP condition generating timing is
different in the standard clock mode and the high-speed clock
mode. Refer to Figure 35, the STOP condition generating timing
diagram, and Table 10, the STOP condition generating timing
table.
SCL
Fig. 36 START condition detecting timing diagram
SCL release time
SCL
SDA
BB flag
SDA
Hold time
Fig. 35 STOP condition generating timing diagram
Table 10 STOP condition generating timing table
Standard clock mode
High-speed clock mode
Item
5.0 µs (20 cycles)
3.0 µs (12 cycles)
Setup time
4.5 µs (18 cycles)
2.5 µs (10 cycles)
Hold time
Note: Absolute time at φ = 4 MHz. The value in parentheses denotes the
number of φ cycles.
Rev.1.01
Jul 01, 2003
page 35 of 89
Setup
time
Hold time
BB flag
reset
time
Fig. 37 STOP condition detecting timing diagram
Table 11 START condition/STOP condition detecting conditions
Standard clock mode
High-speed clock mode
SCL release time
Setup time
BB flag set/
reset time
Setup
time
Hold time
BB flag
reset
time
BB flag
Hold time
I2C status register
write signal
Setup
time
SSC value + 1 cycle (6.25 µs)
4 cycles (1.0 µs)
SSC value + 1 cycle < 4.0 µs (3.125 µs)
2 cycles (1.0 µs)
2
SSC value + 1 cycle < 4.0 µs (3.125 µs) 2 cycles (0.5 µs)
2
SSC value –1 + 2 cycles (3.375 µs) 3.5 cycles (0.875 µs)
2
Note: Unit : Cycle number of system clock φ
SSC value is the decimal notation value of the START/STOP condition set bits SSC4 to SSC0. Do not set “0” or an odd number to SSC
value. The value in parentheses is an example when the I2C START/
STOP condition control register is set to “1816” at φ = 4 MHz.
7516 Group
[I2C START/STOP Condition Control Register
(S2D)] 003016
The I2C START/STOP condition control register (address 003016)
controls START/STOP condition detection.
•Bits 0 to 4: START/STOP condition set bit (SSC4–SSC0)
SCL release time, setup time, and hold time change the detection
condition by value of the main clock divide ratio selection bit and
the oscillation frequency f(XIN) because these time are measured
by the internal system clock. Accordingly, set the proper value to
the START/STOP condition set bits (SSC4 to SSC0) in considered
of the system clock frequency. Refer to Table 11.
Do not set “000002” or an odd number to the START/STOP condition set bit (SSC4 to SSC0).
Refer to Table 12, the recommended set value to START/STOP
condition set bits (SSC4–SSC0) for each oscillation frequency.
•Bit 5: SCL/SDA interrupt pin polarity selection bit (SIP)
An interrupt can occur when detecting the falling or rising edge of
the SCL or SDA pin. This bit selects the polarity of the SCL or
SDA pin interrupt pin.
•Bit 6: SCL/SDA interrupt pin selection bit (SIS)
This bit selects the pin of which interrupt becomes valid between
the SCL pin and the SDA pin.
Note: When changing the setting of the SCL/SDA interrupt pin polarity selection bit, the SCL /S DA interrupt pin selection bit, or the I 2 C-BUS
interface enable bit ES0, the S CL/SDA interrupt request bit may be
set. When selecting the SCL/SDA interrupt source, disable the interrupt before the SCL/SDA interrupt pin polarity selection bit, the S CL/
S DA interrupt pin selection bit, or the I 2C-BUS interface enable bit
ES0 is set. Reset the request bit to “0” after setting these bits, and
enable the interrupt.
Rev.1.01
Jul 01, 2003
page 36 of 89
Address Data Communication
There are two address data communication formats, namely, 7-bit
addressing format and 10-bit addressing format. The respective
address communication formats are described below.
➀ 7-bit addressing format
To adapt the 7-bit addressing format, set the 10BIT SAD bit of
the I 2C control register (address 002E16) to “0.” The first 7-bit
address data transmitted from the master is compared with the
high-order 7-bit slave address stored in the I2C address register
(address 002C16). At the time of this comparison, address comparison of the RWB bit of the I2 C address register (address
002C 16) is not performed. For the data transmission format
when the 7-bit addressing format is selected, refer to Figure 39,
(1) and (2).
➁ 10-bit addressing format
To adapt the 10-bit addressing format, set the 10BIT SAD bit of
the I 2C control register (address 002E 16) to “1.” An address
comparison is performed between the first-byte address data
transmitted from the master and the 8-bit slave address stored
in the I2C address register (address 002C16). At the time of this
comparison, an address comparison between the RWB bit of
the I 2C address register (address 002C 16) and the R/W bit
which is the last bit of the address data transmitted from the
master is made. In the 10-bit addressing mode, the RWB bit
which is the last bit of the address data not only specifies the
direction of communication for control data, but also is processed as an address data bit.
When the first-byte address data agree with the slave address,
the AAS bit of the I2C status register (address 002D16) is set to
“1.” After the second-byte address data is stored into the I 2C
data shift register (address 002B16), perform an address comparison between the second-byte data and the slave address
by software. When the address data of the 2 bytes agree with
the slave address, set the RWB bit of the I2C address register
(address 002C16) to “1” by software. This processing can make
the 7-bit slave address and R/W data agree, which are received after a RESTART condition is detected, with the value of
the I2C address register (address 002C16). For the data transmission format when the 10-bit addressing format is selected,
refer to Figure 39, (3) and (4).
7516 Group
b7
b0
SIS SIP SSC4 SSC3 SSC2 SSC1 SSC0
I2C START/STOP condition
control register
(S2D : address 003016)
START/STOP condition set bit
SCL/SDA interrupt pin polarity
selection bit
0 : Falling edge active
1 : Rising edge active
SCL/SDA interrupt pin selection bit
0 : SDA valid
1 : SCL valid
Reserved
Do not write “1” to this bit.
Fig. 38 Structure of I2C START/STOP condition control register
Table 12 Recommended set value to START/STOP condition set bits (SSC4–SSC0) for each oscillation frequency
Oscillation
frequency
f(XIN) (MHz)
Main clock
divide ratio
System
clock φ
(MHz)
8
2
4
8
8
1
4
2
2
2
2
1
START/STOP
condition
control register
SCL release time
(µs)
Setup time
(µs)
Hold time
(µs)
XXX11010
XXX11000
XXX00100
XXX01100
XXX01010
XXX00100
6.75 µs (27 cycles)
6.25 µs (25 cycles)
5.0 µs (5 cycles)
6.5 µs (13 cycles)
5.5 µs (11 cycles)
5.0 µs (5 cycles)
3.375 µs (13.5 cycles)
3.125 µs (12.5 cycles)
2.5 µs (2.5 cycles)
3.25 µs (6.5 cycles)
2.75 µs (5.5 cycles)
2.5 µs (2.5 cycles)
3.375 µs (13.5 cycles)
3.125 µs (12.5 cycles)
2.5 µs (2.5 cycles)
3.25 µs (6.5 cycles)
2.75 µs (5.5 cycles)
2.5 µs (2.5 cycles)
Note: Do not set an odd number to the START/STOP condition set bit (SSC4 to SSC0).
(1) A master-transmitter transnmits data to a slave-receiver
S
Slave address R/W
7 bits
A
“0”
Data
A
1 to 8 bits
Data
A/A
P
A
P
1 to 8 bits
(2) A master-receiver receives data from a slave-transmitter
S
Slave address R/W
7 bits
A
“1”
Data
A
1 to 8 bits
Data
1 to 8 bits
(3) A master-transmitter transmits data to a slave-receiver with a 10-bit address
S
Slave address
R/W
1st 7 bits
7 bits
A
“0”
Slave address
2nd bytes
A
Data
1 to 8 bits
8 bits
Data
A
A/A
P
1 to 8 bits
(4) A master-receiver receives data from a slave-transmitter with a 10-bit address
S
Slave address
R/W
1st 7 bits
7 bits
S : START condition
A : ACK bit
Sr : Restart condition
“0”
A
Slave address
2nd bytes
8 bits
P : STOP condition
R/W : Read/Write bit
Jul 01, 2003
Sr
Slave address
R/W
1st 7 bits
7 bits
: Master to slave
: Slave to master
Fig. 39 Address data communication format
Rev.1.01
A
page 37 of 89
“1”
A
Data
1 to 8 bits
A
Data
1 to 8 bits
A
P
7516 Group
Example of Master Transmission
An example of master transmission in the standard clock mode, at
the SCL frequency of 100 kHz and in the ACK return mode is
shown below.
➀ Set a slave address in the high-order 7 bits of the I2C address
register (address 002C16) and “0” into the RWB bit.
➁ Set the ACK return mode and SCL = 100 kHz by setting “8516”
in the I2C clock control register (address 002F16).
➂ Set “0016” in the I2C status register (address 002D16) so that
transmission/reception mode can become initializing condition.
➃ Set a communication enable status by setting “0816” in the I2C
control register (address 002E16).
➄ Confirm the bus free condition by the BB flag of the I2C status
register (address 002D16).
➅ Set the address data of the destination of transmission in the
high-order 7 bits of the I2C data shift register (address 002B16)
and set “0” in the least significant bit.
➆ Set “F016” in the I2C status register (address 002D16) to generate a START condition. At this time, an SCL for 1 byte and an
ACK clock automatically occur.
➇ Set transmit data in the I2C data shift register (address 002B16).
At this time, an SCL and an ACK clock automatically occur.
➈ When transmitting control data of more than 1 byte, repeat step
➇.
➉ Set “D016” in the I2C status register (address 002D16) to generate a STOP condition if ACK is not returned from slave
reception side or transmission ends.
Example of Slave Reception
An example of slave reception in the high-speed clock mode, at
the SCL frequency of 400 kHz, in the ACK non-return mode and
using the addressing format is shown below.
➀ Set a slave address in the high-order 7 bits of the I2C address
register (address 002C16) and “0” in the RWB bit.
➁ Set the no ACK clock mode and SCL = 400 kHz by setting
“2516” in the I2C clock control register (address 002F16).
➂ Set “0016” in the I2C status register (address 002D16) so that
transmission/reception mode can become initializing condition.
➃ Set a communication enable status by setting “0816” in the I2C
control register (address 002E16).
➄ When a START condition is received, an address comparison is
performed.
➅ •When all transmitted addresses are “0” (general call):
AD0 of the I 2C status register (address 002D16) is set to “1”
and an interrupt request signal occurs.
• When the transmitted addresses agree with the address set
in ➀:
AAS of the I2C status register (address 002D16) is set to “1”
and an interrupt request signal occurs.
• In the cases other than the above AD0 and AAS of the I2C status register (address 002D16) are set to “0” and no interrupt
request signal occurs.
➆ Set dummy data in the I2C data shift register (address 002B16).
➇ When receiving control data of more than 1 byte, repeat step ➆.
➈ When a STOP condition is detected, the communication ends.
Rev.1.01
Jul 01, 2003
page 38 of 89
7516 Group
■Precautions when using multi-master I2CBUS interface
(1) Read-modify-write instruction
The precautions when the read-modify-write instruction such as
SEB, CLB etc. is executed for each register of the multi-master
I2C-BUS interface are described below.
• I2C data shift register (S0: address 002B16)
When executing the read-modify-write instruction for this register during transfer, data may become a value not intended.
• I2C address register (S0D: address 002C16)
When the read-modify-write instruction is executed for this register at detecting the STOP condition, data may become a value
not intended. It is because H/W changes the read/write bit
(RWB) at the above timing.
• I2C status register (S1: address 002D16)
Do not execute the read-modify-write instruction for this register
because all bits of this register are changed by H/W.
• I2C control register (S1D: address 002E16)
When the read-modify-write instruction is executed for this register at detecting the START condition or at completing the byte
transfer, data may become a value not intended. Because H/W
changes the bit counter (BC0-BC2) at the above timing.
• I2C clock control register (S2: address 002F16)
The read-modify-write instruction can be executed for this register.
• I 2 C START/STOP condition control register (S2D: address
003016)
The read-modify-write instruction can be executed for this register.
(2) START condition generating procedure using multi-master
1. Procedure example (The necessary conditions of the generating procedure are described in Items 2 to 5 below.
•
•
•
LDA —
SEI
BBS 5, S1, BUSBUSY
BUSFREE:
STA S0
LDM #$F0, S1
CLI
(Taking out of slave address value)
(Interrupt disabled)
(BB flag confirming and branch process)
(Writing of slave address value)
(Trigger of START condition generating)
(Interrupt enabled)
•
•
•
BUSBUSY:
CLI •
(Interrupt enabled)
•
•
2. Use “Branch on Bit Set” of “BBS 5, $002D, –” for the BB flag
confirming and branch process.
3. Use “STA $2B, STX $2B” or “STY $2B” of the zero page addressing instruction for writing the slave address value to the
I2C data shift register.
4. Execute the branch instruction of Item 2 and the store instruction of Item 3 continuously, as shown in the procedure example
above.
Rev.1.01
Jul 01, 2003
page 39 of 89
5. Disable interrupts during the following three process steps:
• BB flag confirming
• Writing of slave address value
• Trigger of START condition generating
When the condition of the BB flag is bus busy, enable interrupts
immediately.
(3) RESTART condition generating procedure
1. Procedure example (The necessary conditions for the procedure are described in items 2 to 4 below.)
Execute the following procedure when the PIN bit is “0.”
•
•
•
LDM #$00, S1
LDA —
SEI
STA S0
LDM #$F0, S1
CLI
(Select slave receive mode)
(Take out of slave address value)
(Disable interrupt)
(Write slave address value)
(Trigger RESTART condition generation)
(Enable interrupt)
•
•
•
2. Select the slave receive mode when the PIN bit is “0.” Do not
write “1” to the PIN bit. Neither “0” nor “1” is specified as input to
the BB bit.
The TRX bit becomes “0” and the SDA pin is released.
3. The SCL pin is released by writing the slave address value to
the I2C data shift register.
4. Disable interrupts during the following two process steps:
• Write slave address value
• Trigger RESTART condition generation
(4) Writing to I2C status register
Do not execute an instruction to set the PIN bit to “1” from “0” and
an instruction to set the MST and TRX bits to “0” from “1” simultaneously. Because it may enter the state that the S CL pin is
released and the S DA pin is released after about one machine
cycle. Do not execute an instruction to set the MST and TRX bits
to “0” from “1” simultaneously when the PIN bit is “1.” Because it
may become the same as above.
(5) Process of after STOP condition generating
Do not write data in the I2C data shift register S0 and the I2C status register S1 until the bus busy flag BB becomes “0” after
generating the STOP condition in the master mode. Because the
STOP condition waveform might not be normally generated.
Reading to the above registers do not have the problem.
7516 Group
PULSE WIDTH MODULATION (PWM)
PWM Operation
The 7516 group has a PWM function with an 8-bit resolution,
based on a signal that is the clock input XIN or that clock input divided by 2.
When bit 0 (PWM enable bit) of the PWM control register is set to
“1”, operation starts by initializing the PWM output circuit, and
pulses are output starting at an “H”.
If the PWM register or PWM prescaler is updated during PWM
output, the pulses will change in the cycle after the one in which
the change was made.
Data Setting
The PWM output pin also functions as port P4 4 . Set the PWM
period by the PWM prescaler, and set the “H” term of output pulse
by the PWM register.
If the value in the PWM prescaler is n and the value in the PWM
register is m (where n = 0 to 255 and m = 0 to 255) :
PWM period = 255 ✕ (n+1) / f(XIN)
= 31.875 ✕ (n+1) µs
(when f(XIN) = 8 MHz,count source selection bit = “0”)
Output pulse “H” term = PWM period ✕ m / 255
= 0.125 ✕ (n+1) ✕ m µs
(when f(XIN) = 8 MHz,count source selection bit = “0”)
31.875 ✕ m ✕ (n+1)
µs
255
PWM output
T = [31.875 ✕ (n+1)] µs
m: Contents of PWM register
n : Contents of PWM prescaler
T : PWM period (when f(XIN) = 8 MHz, count
source selection bit = “0”)
Fig. 40 Timing of PWM period
Data bus
PWM
prescaler pre-latch
PWM
register pre-latch
Transfer control circuit
PWM
prescaler latch
PWM
register latch
PWM prescaler
PWM register
Count source
selection bit
(XCIN
“0”
XIN
at low-speed mode)
1/2
Port P44
“1”
Port P44 latch
PWM enable bit
Fig. 41 Block diagram of PWM function
Rev.1.01
Jul 01, 2003
page 40 of 89
7516 Group
b7
b0
PWM control register
(PWMCON : address 001D16)
PWM function enable bit
0: PWM disabled
1: PWM enabled
Count source selection bit
0: f(XIN) (f(XCIN) at low-speed mode)
1: f(XIN)/2 (f(XCIN)/2 at low-speed mode)
Not used (return “0” when read)
Fig. 42 Structure of PWM control register
A
B
B = C
T2
T
C
PWM output
T
PWM register
write signal
T
T2
(Changes “H” term from “A” to “B”.)
PWM prescaler
write signal
(Changes PWM period from “T” to “T2”.)
When the contents of the PWM register or PWM prescaler have changed, the PWM
output will change from the next period after the change.
Fig. 43 PWM output timing when PWM register or PWM prescaler is changed
■Note
The PWM starts after the PWM function enable bit is set to enable and “L” level is output from the PWM pin.
The length of this “L” level output is as follows:
Rev.1.01
n+1
2 • f(XIN)
sec
(Count source selection bit = 0, where n is the value set in the prescaler)
n+1
f(XIN)
sec
(Count source selection bit = 1, where n is the value set in the prescaler)
Jul 01, 2003
page 41 of 89
7516 Group
A-D CONVERTER
[A-D Conversion Registers (ADL, ADH)]
003516, 003616
b0
b7
AD control register
(ADCON : address 003416)
Analog input pin selection bits
The A-D conversion registers are read-only registers that store the
result of an A-D conversion. Do not read these registers during an
A-D conversion
b2 b1 b0
0
0
0
0
1
1
1
1
[AD Control Register (ADCON)] 003416
The AD control register controls the A-D conversion process. Bits
0 to 2 select a specific analog input pin. Bit 4 indicates the
completion of an A-D conversion. The value of this bit remains at
“0” during an A-D conversion and changes to “1” when an A-D
conversion ends. Writing “0” to this bit starts the A-D conversion.
0
0
1
1
0
0
1
1
0: P30/AN0
1: P31/AN1
0: P32/AN2
1: P33/AN3
0: P34/AN4
1: P35/AN5
0: P36/AN6
1: P37/AN7
Not used (returns “0” when read)
A-D conversion completion bit
0: Conversion in progress
1: Conversion completed
Comparison Voltage Generator
Not used (returns “0” when read)
The comparison voltage generator divides the voltage between
AVSS and VREF into 1024 and outputs the divided voltages.
Fig. 44 Structure of AD control register
Channel Selector
The channel selector selects one of ports P30/AN0 to P37/AN7 and
inputs the voltage to the comparator.
10-bit reading
(Read address 003616 before 003516)
Comparator and Control Circuit
(Address 003616)
The comparator and control circuit compare an analog input voltage with the comparison voltage, and the result is stored in the
A-D conversion registers. When an A-D conversion is completed,
the control circuit sets the A-D conversion completion bit and the
A-D interrupt request bit to “1”.
Note that because the comparator consists of a capacitor coupling, set f(XIN) to 500 kHz or more during an A-D conversion.
When the A-D converter is operated at low-speed mode, f(X IN )
and f(XCIN) do not have the lower limit of frequency, because of
the A-D converter has a built-in self-oscillation circuit.
(Address 003516)
b7
b0
b9 b8
b7
b0
b7 b6 b5 b4 b3 b2 b1 b0
Note : The high-order 6 bits of address 003616 become “0”
at reading.
8-bit reading (Read only address 003516)
b7
(Address 003516)
b0
b9 b8 b7 b6 b5 b4 b3 b2
Fig. 45 Structure of A-D conversion registers
Data bus
AD control register
(Address 003416)
b7
b0
3
A-D interrupt request
A-D control circuit
Channel selector
P30/AN0
P31/AN1
P32/AN2
P33/AN3
P34/AN4
P35/AN5
P36/AN6
P37/AN7
Comparator
A-D conversion high-order register (Address 003616)
A-D conversion low-order register (Address 003516)
10
Resistor ladder
VREF AVSS
Fig. 46 Block diagram of A-D converter
Rev.1.01
Jul 01, 2003
page 42 of 89
7516 Group
WATCHDOG TIMER
●Watchdog timer H count source selection bit operation
Bit 7 of the watchdog timer control register (address 003916) permits selecting a watchdog timer H count source. When this bit is
set to “0”, the count source becomes the underflow signal of
watchdog timer L. The detection time is set to 131.072 ms at f(XIN)
= 8 MHz frequency and 32.768 s at f(XCIN) = 32 kHz frequency.
When this bit is set to “1”, the count source becomes the signal
divided by 16 for f(XIN) (or f(XCIN)). The detection time in this case
is set to 512 µs at f(XIN) = 8 MHz frequency and 128 ms at f(XCIN)
= 32 kHz frequency. This bit is cleared to “0” after reset.
The watchdog timer gives a mean of returning to the reset status
when a program cannot run on a normal loop (for example, because of a software run-away). The watchdog timer consists of an
8-bit watchdog timer L and an 8-bit watchdog timer H.
Standard Operation of Watchdog Timer
When any data is not written into the watchdog timer control register (address 0039 16 ) after reset, the watchdog timer is in the
stop state. The watchdog timer starts to count down by writing an
optional value into the watchdog timer control register (address
003916) and an internal reset occurs at an underflow of the watchdog timer H.
Accordingly, programming is usually performed so that writing to
the watchdog timer control register (address 0039 16 ) may be
started before an underflow. When the watchdog timer control register (address 003916) is read, the values of the high-order 6 bits
of the watchdog timer H, STP instruction disable bit, and watchdog timer H count source selection bit are read.
●Operation of STP instruction disable bit
Bit 6 of the watchdog timer control register (address 003916) permits disabling the STP instruction when the watchdog timer is in
operation.
When this bit is “0”, the STP instruction is enabled.
When this bit is “1”, the STP instruction is disabled, once the STP
instruction is executed, an internal reset occurs. When this bit is
set to “1”, it cannot be rewritten to “0” by program. This bit is
cleared to “0” after reset.
●Initial value of watchdog timer
At reset or writing to the watchdog timer control register (address
003916), each watchdog timer H and L are set to “FF16.”
“FF16” is set when
watchdog timer
control register is
written to.
XCIN
Data bus
“0 ”
“10”
Main clock division
ratio selection bits
(Note)
XIN
“FF16” is set when
watchdog timer
control register is
written to.
Watchdog timer L (8)
1/16
“1 ”
“00”
“01”
Watchdog timer H (8)
Watchdog timer H count
source selection bit
STP instruction disable bit
STP instruction
Reset
circuit
RESET
Note: Any one of high-speed, middle-speed or low-speed mode is selected by bits 7 and 6 of the CPU mode register.
Fig. 47 Block diagram of Watchdog timer
b7
b0
Watchdog timer control register
(WDTCON : address 003916)
Watchdog timer H (for read-out of high-order 6 bit)
STP instruction disable bit
0: STP instruction enabled
1: STP instruction disabled
Watchdog timer H count source selection bit
0: Watchdog timer L underflow
1: f(XIN)/16 or f(XCIN)/16
Fig. 48 Structure of Watchdog timer control register
Rev.1.01
Jul 01, 2003
page 43 of 89
Internal reset
7516 Group
RESET CIRCUIT
To reset the microcomputer, RESET pin must be held at an “L”
level for 20 cycles or more of XIN. Then the RESET pin is returned
to an “H” level (the power source voltage must be between 2.7 V
and 5.5 V, and the oscillation must be stable), reset is released.
After the reset is completed, the program starts from the address
contained in address FFFD 16 (high-order byte) and address
FFFC16 (low-order byte). Make sure that the reset input voltage is
less than 0.54 V for VCC of 2.7 V.
Poweron
RESET
VCC
Power source
voltage
0V
Reset input
voltage
0V
(Note)
0.2VCC
Note : Reset release voltage; Vcc = 2.7 V
RESET
VCC
Power source
voltage detection
circuit
Fig. 49 Reset circuit example
XIN
φ
RESET
RESETOUT
Address
?
?
?
?
FFFC
FFFD
ADH,L
Reset address from the vector table.
?
Data
?
?
?
ADL
ADH
SYNC
XIN: 8 to 13 clock cycles
Notes 1: The frequency relation of f(XIN) and f(φ) is f(XIN) = 8 • f(φ).
2: The question marks (?) indicate an undefined state that depends on the previous state.
3: All signals except XIN and RESET are internals.
Fig. 50 Reset sequence
Rev.1.01
Jul 01, 2003
page 44 of 89
7516 Group
Address Register contents
Address Register contents
(1)
Port P0 (P0)
000016
0016
(37) A-D control register (ADCON)
(2)
Port P0 direction register (P0D)
000116
0016
(38) A-D conversion low-order register (ADL) 003516 X X X X X X X X
(3)
Port P1 (P1)
000216
0016
(39) A-D conversion high-order register (ADH) 003616 0 0 0 0 0 0 X X
(4)
Port P1 direction register (P1D)
000316
0016
(40) MISRG
003816
(5)
Port P2 (P2)
000416
0016
(41) Watchdog timer control register (WDTCON)
003916 0 0 1 1 1 1 1 1
(6)
Port P2 direction register (P2D)
000516
0016
(42) Interrupt edge selection register (INTEDGE)
003A16
(7)
Port P3 (P3)
000616
0016
(43) CPU mode register (CPUM)
003B16 0 1 0 0 1 0 0 0
(8)
Port P3 direction register (P3D)
000716
0016
(44) Interrupt request register 1 (IREQ1)
003C16
0016
(9)
Port P4 (P4)
000816
0016
(45) Interrupt request register 2 (IREQ2)
003D16
0016
(10) Port P4 direction register (P4D)
000916
0016
(46) Interrupt control register 1 (ICON1)
003E16
0016
(11) Serial I/O2 control register 1 (SIO2CON1)
001516
0016
(47) Interrupt control register 2 (ICON2)
003F16
0016
(12) Serial I/O2 control register 2 (SIO2CON2)
001616 0 0 0 0 0 1 1 1
(48) Processor status register
(PS)
(13) Serial I/O2 register (SIO2)
001716 X X X X X X X X
(49) Program counter
(PCH)
FFFD16 contents
(14) Transmit/Receive buffer register (TB/RB)
001816 X X X X X X X X
(PCL)
FFFC16 contents
(15) Serial I/O1 status register (SIOSTS)
001916 1 0 0 0 0 0 0 0
(16) Serial I/O1 control register (SIOCON)
001A16
(17) UART control register (UARTCON)
001B16 1 1 1 0 0 0 0 0
(18) Baud rate generator (BRG)
001C16 X X X X X X X X
(19) PWM control register (PWMCON)
001D16
(20) PWM prescaler (PREPWM)
001E16 X X X X X X X X
(21) PWM register (PWM)
001F16 X X X X X X X X
(22) Prescaler 12 (PRE12)
002016
FF16
(23) Timer 1 (T1)
002116
0116
(24) Timer 2 (T2)
002216
0016
(25) Timer XY mode register (TM)
002316
0016
(26) Prescaler X (PREX)
002416
FF16
(27) Timer X (TX)
002516
FF16
(28) Prescaler Y (PREY)
002616
FF16
(29) Timer Y (TY)
002716
FF16
(30) Timer count source selection register (TCSS)
002816
0016
(31) I2C data shift register (S0)
002B16 X X X X X X X X
(32) I2C address regiter (S0D)
002C16
(33) I2C status register (S1)
002D16 0 0 0 1 0 0 0 X
(34) I2C control register (S1D)
002E16
0016
(35) I2C clock control register (S2)
002F16
0016
(36)
I2C
0016
0016
start/stop condition control register (S2D) 003016 0 0 0 X X X X X
Fig. 51 Internal status at reset
Rev.1.01
0016
Jul 01, 2003
page 45 of 89
003416 0 0 0 1 0 0 0 0
0016
0016
X X X X X 1 X X
Note : X : Not fixed
Since the initial values for other than above mentioned registers and
RAM contents are indefinite at reset, they must be set.
7516 Group
CLOCK GENERATING CIRCUIT
The 7516 group has two built-in oscillation circuits: main clock XINX OUT oscillation circuit and sub clock X CIN-X COUT oscillation
circuit. An oscillation circuit can be formed by connecting a resonator between XIN and XOUT (XCIN and X COUT). Use the circuit
constants in accordance with the resonator manufacturer’s recommended values. No external resistor is needed between XIN and
XOUT since a feed-back resistor exists on-chip. However, an external feed-back resistor is needed between XCIN and XCOUT.
Immediately after power on, only the XIN oscillation circuit starts
oscillating, and XCIN and XCOUT pins function as I/O ports.
Frequency Control
(1) Middle-speed mode
The internal clock φ is the frequency of XIN divided by 8. After reset is released, this mode is selected.
(2) High-speed mode
RESET pin until the oscillation is stable since a wait time will not
be generated.
(2) Wait mode
If the WIT instruction is executed, the internal clock φ stops at an
“H” level, but the oscillator does not stop. The internal clock φ restarts at reset or when an interrupt is received. Since the oscillator
does not stop, normal operation can be started immediately after
the clock is restarted.
To ensure that the interrupts will be received to release the STP or
WIT state, their interrupt enable bits must be set to “1” before executing of the STP or WIT instruction.
When releasing the STP state, the prescaler 12 and timer 1 will
start counting the clock XIN divided by 16. Accordingly, set the
timer 1 interrupt enable bit to “0” before executing the STP instruction.
The internal clock φ is half the frequency of XIN.
■Note
(3) Low-speed mode
When using the oscillation stabilizing time set after STP instruction
released bit set to “1”, evaluate time to stabilize oscillation of the
used oscillator and set the value to the timer 1 and prescaler 12.
The internal clock φ is half the frequency of XCIN.
■Note
If you switch the mode between middle/high-speed and lowspeed, stabilize both XIN and XCIN oscillations. The sufficient time
is required for the sub-clock to stabilize, especially immediately after power on and at returning from the stop mode. When switching
the mode between middle/high-speed and low-speed, set the frequency on condition that f(XIN) > 3•f(XCIN).
XCIN
(4) Low power dissipation mode
The low power consumption operation can be realized by stopping
the main clock XIN in low-speed mode. To stop the main clock, set
bit 5 of the CPU mode register to “1.” When the main clock XIN is
restarted (by setting the main clock stop bit to “0”), set sufficient
time for oscillation to stabilize.
The sub-clock XCIN-XCOUT oscillation circuit can not directly input
clocks that are generated externally. Accordingly, make sure to
cause an external resonator to oscillate.
XCOUT
Rf
CCIN
XIN
XOUT
Rd
CCOUT
CI N
Fig. 52 Ceramic resonator circuit
Oscillation Control
(1) Stop mode
If the STP instruction is executed, the internal clock φ stops at an
“H” level, and XIN and XCIN oscillation stops. When the oscillation
stabilizing time set after STP instruction released bit is “0,” the
prescaler 12 is set to “FF16” and timer 1 is set to “0116.” When the
oscillation stabilizing time set after STP instruction released bit is
“1,” set the sufficient time for oscillation of used oscillator to stabilize since nothing is set to the prescaler 12 and timer 1.
Either X IN or X CIN divided by 16 is input to the prescaler 12 as
count source. Oscillator restarts when an external interrupt is received, but the internal clock φ is not supplied to the CPU (remains
at “H”) until timer 1 underflows. The internal clock φ is supplied for
the first time, when timer 1 underflows. This ensures time for the
clock oscillation using the ceramic resonators to be stabilized.
When the oscillator is restarted by reset, apply “L” level to the
Rev.1.01
Jul 01, 2003
page 46 of 89
XCIN
XCOUT
Rf
XIN
XOUT
Open
Rd
External oscillation
circuit
CCIN
CCOUT
Vcc
Vss
Fig. 53 External clock input circuit
COUT
7516 Group
■Notes on middle-speed mode automatic
switch set bit
b7
b0
MISRG
(MISRG : address 003816)
When the middle-speed mode automatic switch set bit is set to “1”
while operating in the low-speed mode, by detecting the rising/falling edge of the SCL or SDA pin, XIN oscillation automatically starts
and the mode is automatically switched to the middle-speed
mode. The timing which changes from the low-speed mode to the
middle-speed mode can be set as 4.5 to 5.5 cycle, or 6.5 to 7.5
cycle in the low-speed mode by the middle-speed mode automatic
switch waiting time set bit. Select according to the oscillation start
characteristic of the XIN oscillator to be used.
Oscillation stabilizing time set after STP instruction
released bit
0: Automatically set “0116” to Timer 1,
“FF16” to Prescaler 12
1: Automatically set nothing
Middle-speed mode automatic switch set bit
0: Not set automatically
1: Automatic switching enable (Notes 1, 2)
Middle-speed mode automatic switch wait time set bit
0: 4.5 to 5.5 machine cycles
1: 6.5 to 7.5 machine cycles
Middle-speed mode automatic switch start bit
(Depending on program)
0: Invalid
1: Automatic switch start (Note 2)
Not used (return “0” when read)
Notes 1: While operating in the low-speed mode, the mode can be automatically
switched to the middle-speed mode by the SCL/SDA interrupt.
2: When the mode is automatically switched from the low-speed mode to
the middle-speed mode, the value of CPU mode register (address
003B16) changes.
Fig. 54 Structure of MISRG
XCOUT
XCIN
“0”
“1”
Port XC
switch bit
XOUT
XIN
Timer 12 count source
selection bit
Main clock division ratio
selection bits (Note 1)
Low-speed mode
1/2
1/4
Prescaler 12
1/2
High-speed or
middle-speed
mode
FF16
Timer 1
0116
Reset or
STP instruction
(Note 2)
Main clock division ratio
selection bits (Note 1)
Middle-speed mode
Timing φ (internal clock)
High-speed or
low-speed mode
Main clock stop bit
Q
S
R
S Q
STP instruction
WIT instruction
R
Reset
Q S
R
STP instruction
Reset
Interrupt disable flag l
Interrupt request
Notes 1: Any one of high-speed, middle-speed or low-speed mode is selected by bits 7 and 6 of the CPU mode register.
When low-speed mode is selected, set port Xc switch bit (b4) to “1”.
2: When bit 0 of MISRG = “0”
Fig. 55 System clock generating circuit block diagram (Single-chip mode)
Rev.1.01
Jul 01, 2003
page 47 of 89
7516 Group
Reset
C
“0 M4
CM ” ←
“1 6 →
”←
“1
”
→
“0
”
”
“0
4 →
M
”
C ”←
“0
“1 M6 →
C ”←
“1
Middle-speed mode
(f(φ) = 1 MHz)
CM7 = 0
CM6 = 1
CM5 = 0 (8 MHz oscillating)
CM4 = 1 (32 kHz oscillating)
CM7 = 0
CM6 = 0
CM5 = 0 (8 MHz oscillating)
CM4 = 0 (32 kHz stopped)
CM6
“1” ←→ “0”
C
“0 M7
CM ” ←
“1 6 →
“1
”←
”
→
“0
”
CM4
“1” ←→ “0”
CM4
“1” ←→ “0”
CM7 = 0
CM6 = 1
CM5 = 0 (8 MHz oscillating)
CM4 = 0 (32 kHz stopped)
High-speed mode
(f(φ) = 4 MHz)
CM6
“1” ←→ “0”
High-speed mode
(f(φ) = 4 MHz)
CM7 = 0
CM6 = 0
CM5 = 0 (8 MHz oscillating)
CM4 = 1 (32 kHz oscillating)
CM7
“1” ←→ “0”
Middle-speed mode
(f(φ) = 1 MHz)
CM5
“1” ←→ “0”
Low-speed mode
(f(φ)=16 kHz)
CM7 = 1
CM6 = 0
CM5 = 0 (8 MHz oscillating)
CM4 = 1 (32 kHz oscillating)
Low-speed mode
(f(φ)=16 kHz)
CM7 = 1
CM6 = 0
CM5 = 1 (8 MHz stopped)
CM4 = 1 (32 kHz oscillating)
b7
b4
CPU mode register
(CPUM : address 003B16)
CM4 : Port Xc switch bit
0 : I/O port function (stop oscillating)
1 : XCIN-XCOUT oscillating function
CM5 : Main clock (XIN- XOUT) stop bit
0 : Operating
1 : Stopped
CM7, CM6: Main clock division ratio selection bits
b7 b6
0 0 : φ = f(XIN)/2 ( High-speed mode)
0 1 : φ = f(XIN)/8 (Middle-speed mode)
1 0 : φ = f(XCIN)/2 (Low-speed mode)
1 1 : Not available
Notes 1 : Switch the mode by the allows shown between the mode blocks. (Do not switch between the modes directly without an allow.)
2 : The all modes can be switched to the stop mode or the wait mode and return to the source mode when the stop mode or the wait mode is
ended.
3 : Timer operates in the wait mode.
4 : When bit 0 of MISRG is “0” and the stop mode is ended, a delay of approximately 1 ms occurs by connecting timer 1 in middle/high-speed
mode.
5 : When bit 0 of MISRG is “0” and the stop mode is ended, the following is performed.
(1) After the clock is restarted, a delay of approximately 250 ms occurs in low-speed mode if Timer 12 count source selection bit is “0”.
(2) After the clock is restarted, a delay of approximately 16 ms occurs in low-speed mode if Timer 12 count source selection bit is “1”.
6 : Wait until oscillation stabilizes after oscillating the main clock XIN before the switching from the low-speed mode to middle/high-speed
mode.
7 : The example assumes that 8 MHz is being applied to the XIN pin and 32 kHz to the XCIN pin. φ indicates the internal clock.
Fig. 56 State transitions of system clock
Rev.1.01
Jul 01, 2003
page 48 of 89
7516 Group
FLASH MEMORY MODE
Summary
The M37516F8 (flash memory version) has an internal new
DINOR (DIvided bit line NOR) flash memory that can be rewritten
with a single power source when VCC is 5 V, and 2 power sources
when VPP is 5 V and VCC is 3.0-5.5 V in the CPU rewrite and standard serial I/O modes.
For this flash memory, three flash memory modes are available in
which to read, program, and erase: the parallel I/O and standard
serial I/O modes in which the flash memory can be manipulated
using a programmer and the CPU rewrite mode in which the flash
memory can be manipulated by the Central Processing Unit
(CPU).
Table 13 lists the summary of the M37516F8 (flash memory version).
The flash memory of the M37516F8 is divided into User ROM area
and Boot ROM area as shown in Figure 57.
In addition to the ordinary User ROM area to store the MCU operation control program, the flash memory has a Boot ROM area
that is used to store a program to control rewriting in CPU rewrite
and standard serial I/O modes. This Boot ROM area has had a
standard serial I/O mode control program stored in it when
shipped from the factory. However, the user can write a rewrite
control program in this area that suits the user’s application system. This Boot ROM area can be rewritten in only parallel I/O
mode.
Table 13 Summary of M37516F8 (flash memory version)
Item
Power source voltage
VPP voltage (For Program/Erase)
Flash memory mode
Erase block division
User ROM area
Boot ROM area
Program method
Erase method
Program/Erase control method
Number of commands
Number of program/Erase times
ROM code protection
Specifications
Vcc = 2.7– 5.5 V (Note 1)
Vcc = 2.7–3.6 V (Note 2)
4.5-5.5 V, f(XIN) = 8 MHz
3 modes (Parallel I/O mode, Standard serial I/O mode, CPU rewrite mode)
1 block (32 Kbytes)
1 block (4 Kbytes) (Note 3)
Byte program
Batch erasing
Program/Erase control by software command
6 commands
100 times
Available in parallel I/O mode and standard serial I/O mode
Notes 1: The power source voltage must be Vcc = 4.5–5.5 V at program and erase operation.
2: The power source voltage can be Vcc = 3.0–3.6 V also at program and erase operation.
3: The Boot ROM area has had a standard serial I/O mode control program stored in it when shipped from the factory. This Boot ROM area can be
rewritten in only parallel I/O mode.
Rev.1.01
Jul 01, 2003
page 49 of 89
7516 Group
(1) CPU Rewrite Mode
Microcomputer Mode and Boot Mode
In CPU rewrite mode, the internal flash memory can be operated
on (read, program, or erase) under control of the Central Processing Unit (CPU).
In CPU rewrite mode, only the User ROM area shown in Figure 57
can be rewritten; the Boot ROM area cannot be rewritten. Make
sure the program and block erase commands are issued for only
the User ROM area and each block area.
The control program for CPU rewrite mode can be stored in either
User ROM or Boot ROM area. In the CPU rewrite mode, because
the flash memory cannot be read from the CPU, the rewrite control program must be transferred to internal RAM area to be
executed before it can be executed.
The control program for CPU rewrite mode must be written into
the User ROM or Boot ROM area in parallel I/O mode beforehand.
(If the control program is written into the Boot ROM area, the standard serial I/O mode becomes unusable.)
See Figure 57 for details about the Boot ROM area.
Normal microcomputer mode is entered when the microcomputer
is reset with pulling CNVSS pin low. In this case, the CPU starts
operating using the control program in the User ROM area.
When the microcomputer is reset by pulling the P41/INT0 pin high,
the CNVss pin high, the CPU starts operating using the control
program in the Boot ROM area (program start address is FFFC16,
FFFD16 fixation). This mode is called the “Boot” mode.
Block Address
Block addresses refer to the maximum address of each block.
These addresses are used in the block erase command. In case
of the M37516F8, it has only one block.
Parallel I/O mode
800016
Block 1 : 32 kbyte
FFFF16
F00016
4 kbyte
FFFF16
User ROM area
Boot ROM area
BSEL = 0
BSEL = 1
CPU rewrite mode, standard serial I/O mode
800016
Block 1 : 32 kbyte
Product name
Flash memory
start address
M37516F8
800016
FFFF16
F00016
4 kbyte
FFFF16
User ROM area
User area / Boot area selection bit = 0
Boot ROM area
User area / Boot area selection bit = 1
Notes 1: The Boot ROM area can be rewritten in only parallel
input/output mode. (Access to any other areas is inhibited.)
2: To specify a block, use the maximum address in the block.
Fig. 57 Block diagram of built-in flash memory
Rev.1.01
Jul 01, 2003
page 50 of 89
7516 Group
Outline Performance (CPU Rewrite Mode)
CPU rewrite mode is usable in the single-chip or Boot mode. The
only User ROM area can be rewritten in CPU rewrite mode.
In CPU rewrite mode, the CPU erases, programs and reads the internal flash memory by executing software commands. This
rewrite control program must be transferred to the RAM before it
can be executed.
The MCU enters CPU rewrite mode by applying 5 V ± 0.5 V to the
CNVSS pin and setting “1” to the CPU Rewrite Mode Select Bit (bit
1 of address 0FFE16). Software commands are accepted once the
mode is entered.
Use software commands to control program and erase operations.
Whether a program or erase operation has terminated normally or
in error can be verified by reading the status register.
Figure 58 shows the flash memory control register.
Bit 0 is the RY/BY status flag used exclusively to read the operating status of the flash memory. During programming and erase
operations, it is “0” (busy). Otherwise, it is “1” (ready).
Bit 1 is the CPU Rewrite Mode Select Bit. When this bit is set to
“1”, the MCU enters CPU rewrite mode. Software commands are
accepted once the mode is entered. In CPU rewrite mode, the
CPU becomes unable to access the internal flash memory directly.
b7
Therefore, use the control program in the RAM for write to bit 1. To
set this bit to “1”, it is necessary to write “0” and then write “1” in
succession. The bit can be set to “0” by only writing “0”.
Bit 2 is the CPU Rewrite Mode Entry Flag. This flag indicates “1” in
CPU rewrite mode, so that reading this flag can check whether
CPU rewrite mode has been entered or not.
Bit 3 is the flash memory reset bit used to reset the control circuit
of internal flash memory. This bit is used when exiting CPU rewrite
mode and when flash memory access has failed. When the CPU
Rewrite Mode Select Bit is “1”, setting “1” for this bit resets the
control circuit. To set this bit to “1”, it is necessary to write “0” and
then write “1” in succession. To release the reset, it is necessary
to set this bit to “0”.
Bit 4 is the User Area/Boot Area Select Bit. When this bit is set to
“1”, Boot ROM area is accessed, and CPU rewrite mode in Boot
ROM area is available. In Boot mode, this bit is set to “1” automatically. Reprogramming of this bit must be in the RAM.
Figure 59 shows a flowchart for setting/releasing CPU rewrite
mode.
b0
Flash memory control register (address 0FFE16) (Note 1)
FMCR
RY/BY status flag
0: Busy (being programmed or erased)
1: Ready
CPU rewrite mode select bit (Note 2)
0: Normal mode (Software commands invalid)
1: CPU rewrite mode (Software commands acceptable)
CPU rewrite mode entry flag
0: Normal mode
1: CPU rewrite mode
Flash memory reset bit (Note 3)
0: Normal operation
1: Reset
User ROM area / Boot ROM area select bit (Note 4)
0: User ROM area accessed
1: Boot ROM area accessed
Reserved bits (Indefinite at read/ “0” at write)
Notes 1: The contents of flash memory control register are “XXX00001” just after reset release. In the mask
ROM version, this address is reserved area.
2: For this bit to be set to “1”, the user needs to write “0” and then “1” to it in succession. If it is not
this procedure, this bit will not be set to “1”. Additionally, it is required to ensure that no interrupt
will be generated during that interval.
Use the control program in the area except the built-in flash memory for write to this bit.
3: This bit is valid when the CPU rewrite mode select bit is “1”. Set this bit 3 to “0” subsequently after
setting bit 3 to “1”.
4: Use the control program in the area except the built-in flash memory for write to this bit.
Fig. 58 Structure of flash memory control register
Rev.1.01
Jul 01, 2003
page 51 of 89
7516 Group
Start
Single-chip mode or Boot mode (Note 1)
Set CPU mode register (Note 2)
Transfer CPU rewrite mode control program
to RAM
Setting
Jump to control program transferred in RAM
(Subsequent operations are executed by control
program in this RAM)
Set CPU rewrite mode select bit to “1” (by
writing “0” and then “1” in succession)
Check CPU rewrite mode entry flag
Using software command execute erase,
program, or other operation
Execute read array command or reset flash
memory by setting flash memory reset bit (by
writing “1” and then “0” in succession) (Note 3)
Released
Write “0” to CPU rewrite mode select bit
End
Notes 1: When starting the MCU in the single-chip mode, supply 4.5 V to 5.5 V to the CNVss
pin until checking the CPU rewrite mode entry flag.
2: Set bits 6, 7 (main clock division ratio selection bits) at CPU mode register (003B16).
3: Before exiting the CPU rewrite mode after completing erase or program operation,
always be sure to execute the read array command or reset the flash memory.
Fig. 59 CPU rewrite mode set/release flowchart
Rev.1.01
Jul 01, 2003
page 52 of 89
7516 Group
Precautions on CPU Rewrite Mode
Described below are the precautions to be observed when rewriting
the flash memory in CPU rewrite mode.
(1) Operation speed
During CPU rewrite mode, set the internal clock frequency 4.0
MHz or less using the main clock division ratio selection bits (bit
6, 7 at 003B16).
(2) Instructions inhibited against use
The instructions which refer to the internal data of the flash
memory cannot be used during CPU rewrite mode .
(3) Interrupts inhibited against use
The interrupts cannot be used during CPU rewrite mode because they refer to the internal data of the flash memory.
(4) Watchdog timer
In case of the watchdog timer has been running already, the internal reset generated by watchdog timer underflow does not
happen, because of watchdog timer is always clearing during
program or erase operation.
(5) Reset
Reset is always valid. In case of CNVSS = H when reset is released, boot mode is active. So the program starts from the address contained in address FFFC16 and FFFD16 in boot ROM
area.
Rev.1.01
Jul 01, 2003
page 53 of 89
7516 Group
Software Commands (CPU Rewrite Mode)
Table 14 lists the software commands.
After setting the CPU Rewrite Mode Select Bit of the flash memory
control register to “1”, execute a software command to specify an
erase or program operation.
Each software command is explained below.
●Read Array Command (FF16)
The read array mode is entered by writing the command code
“FF16” in the first bus cycle. When an address to be read is input in
one of the bus cycles that follow, the contents of the specified address are read out at the data bus (D0 to D7).
The read array mode is retained intact until another command is
written.
register mode is entered automatically and the contents of the status register is read at the data bus (D0 to D7). The status register
bit 7 (SR7) is set to “0” at the same time the write operation starts
and is returned to “1” upon completion of the write operation. In
this case, the read status register mode remains active until the
next command is written.
____
The RY/BY Status Flag is “0” (busy) during write operation and “1”
(ready) when the write operation is completed as is the status register bit 7.
At program end, program results can be checked by reading bit 4
(SR4) of the status register.
Start
●Read Status Register Command (7016)
The read status register mode is entered by writing the command
code “7016” in the first bus cycle. The contents of the status register are read out at the data bus (D0 to D7) by a read in the second
bus cycle.
The status register is explained in the next section.
Write 4016
Write Write address
Write data
Status register
read
●Clear Status Register Command (5016)
This command is used to clear the bits SR1, SR4, and SR5 of the
status register after they have been set. These bits indicate that
operation has ended in an error. To use this command, write the
command code “5016” in the first bus cycle.
SR7 = 1 ?
or
RY/BY = 1 ?
●Program Command (4016)
Program operation starts when the command code “4016” is written in the first bus cycle. Then, if the address and data to program
are written in the 2nd bus cycle, program operation (data programming and verification) will start.
Whether the write operation is completed can be confirmed by
_____
reading the status register or the RY/BY Status Flag of the flash
memory control register. When the program starts, the read status
NO
YES
NO
S R4 = 0 ?
Program
error
YES
Program completed
(Read array command
“FF16” write)
Fig. 60 Program flowchart
Table 14 List of software commands (CPU rewrite mode)
Command
Cycle number
Mode
Read array
1
Write
Read status register
2
Clear status register
1
Program
First bus cycle
Data
Address
(D0 to D7)
Second bus cycle
Mode
Address
Data
(D0 to D7)
Read
X
SRD (Note 2)
(Note 1)
F F1 6
Write
X
7016
Write
X
5016
2
Write
X
4016
Write
WA (Note 3)
WD (Note 3)
Erase all blocks
2
Write
X
2016
Write
X
2016
Block erase
2
Write
X
2016
Write
(Note 4)
D016
X
Notes 1: X denotes a given address in the User ROM area .
2: SRD = Status Register Data
3: WA = Write Address, WD = Write Data
4: BA = Block Address to be erased (Input the maximum address of each block.)
Rev.1.01
Jul 01, 2003
page 54 of 89
BA
7516 Group
●Erase All Blocks Command (2016/2016)
By writing the command code “2016” in the first bus cycle and the
confirmation command code “2016” in the second bus cycle that
follows, the operation of erase all blocks (erase and erase verify)
starts.
Whether the erase all blocks command is terminated can be con____
firmed by reading the status register or the RY/BY Status Flag of
flash memory control register. When the erase all blocks operation
starts, the read status register mode is entered automatically and
the contents of the status register can be read out at the data bus
(D0 to D7). The status register bit 7 (SR7) is set to “0” at the same
time the erase operation starts and is returned to “1” upon completion of the erase operation. In this case, the read status register
mode remains active until another command is written.
____
The RY/BY Status Flag is “0” during erase operation and “1” when
the erase operation is completed as is the status register bit 7
(SR7).
After the erase all blocks end, erase results can be checked by
reading bit 5 (SRS) of the status register. For details, refer to the
section where the status register is detailed.
●Block Erase Command (2016/D016)
By writing the command code “2016” in the first bus cycle and the
confirmation command code “D016” and the blobk address in the
second bus cycle that follows, the block erase (erase and erase
verify) operation starts for the block address of the flash memory
to be specified.
Whether the block erase operation is completed can be confirmed
____
by reading the status register or the RY/BY Status Flag of flash
memory control register. At the same time the block erase operation starts, the read status register mode is automatically entered,
so that the contents of the status register can be read out. The
status register bit 7 (SR7) is set to “0” at the same time the block
erase operation starts and is returned to “1” upon completion of
the block erase operation. In this case, the read status register
mode remains active until the read array command (FF16) is written.
____
The RY/BY Status Flag is “0” during block erase operation and “1”
when the block erase operation is completed as is the status register bit 7.
After the block erase ends, erase results can be checked by reading bit 5 (SRS) of the status register. For details, refer to the
section where the status register is detailed.
Rev.1.01
Jul 01, 2003
page 55 of 89
Start
Write 2016
Write
2016/D016
Block address
2016:Erase all blocks command
D016:Block erase command
Status register
read
SR7 = 1 ?
or
RY/BY = 1 ?
NO
YES
SR5 = 0 ?
YES
Erase completed
(Read comand “FF16”
write)
Fig. 61 Erase flowchart
NO
Erase error
7516 Group
Status Register (SRD)
The status register shows the operating status of the flash
memory and whether erase operations and programs ended successfully or in error. It can be read in the following ways:
(1) By reading an arbitrary address from the User ROM area after
writing the read status register command (7016)
(2) By reading an arbitrary address from the User ROM area in the
period from when the program starts or erase operation starts
to when the read array command (FF16) is input.
Also, the status register can be cleared by writing the clear status
register command (5016).
After reset, the status register is set to “8016”.
Table 15 shows the status register. Each bit in this register is explained below.
•Erase status (SR5)
The erase status indicates the operating status of erase operation.
If an erase error occurs, it is set to “1”. When the erase status is
cleared, it is set to “0”.
•Program status (SR4)
The program status indicates the operating status of write operation. When a write error occurs, it is set to “1”.
The program status is set to “0” when it is cleared.
If “1” is written for any of the SR5 and SR4 bits, the program,
erase all blocks, and block erase commands are not accepted.
Before executing these commands, execute the clear status register command (5016) and clear the status register.
Also, if any commands are not correct, both SR5 and SR4 are set
to “1”.
•Sequencer status (SR7)
The sequencer status indicates the operating status of the flash
memory. This bit is set to “0” (busy) during write or erase operation
and is set to “1” when these operations ends.
After power-on, the sequencer status is set to “1” (ready).
Table 15 Definition of each bit in status register (SRD)
Symbol
Status name
SR7 (bit7)
SR6 (bit6)
SR5 (bit5)
Sequencer status
Reserved
Erase status
SR4 (bit4)
SR3 (bit3)
Program status
Reserved
SR2 (bit2)
SR1 (bit1)
Reserved
Reserved
SR0 (bit0)
Reserved
Rev.1.01
Jul 01, 2003
page 56 of 89
Definition
“1”
“0”
Ready
-
Busy
-
Terminated in error
Terminated in error
Terminated normally
Terminated normally
-
-
-
-
7516 Group
Full Status Check
By performing full status check, it is possible to know the execution results of erase and program operations. Figure 62 shows a
full status check flowchart and the action to be taken when each
error occurs.
Read status register
SR4 = 1 and
SR5 = 1 ?
YES
Command
sequence error
NO
SR5 = 0 ?
NO
Erase error
Execute the clear status register command (5016)
to clear the status register. Try performing the
operation one more time after confirming that the
command is entered correctly.
Should an erase error occur, the block in error
cannot be used.
YES
SR4 = 0 ?
NO
Program error
Should a program error occur, the block in error
cannot be used.
YES
End (erase, program)
Note: When one of SR5 and SR4 is set to “1”, none of the read array, the program, erase
all blocks, and block erase commands is accepted. Execute the clear status register
command (5016) before executing these commands.
Fig. 62 Full status check flowchart and remedial procedure for errors
Rev.1.01
Jul 01, 2003
page 57 of 89
7516 Group
Functions To Inhibit Rewriting Flash Memory
Version
To prevent the contents of internal flash memory from being read
out or rewritten easily, this MCU incorporates a ROM code protect
function for use in parallel I/O mode and an ID code check function for use in standard serial I/O mode.
●ROM Code Protect Function (in Parallel I/O Mode)
The ROM code protect function is the function to inhibit reading
out or modifying the contents of internal flash memory by using
the ROM code protect control (address FFDB 16 ) in parallel I/O
mode. Figure 63 shows the ROM code protect control (address
FFDB16). (This address exists in the User ROM area.)
If one or both of the pair of ROM Code Protect Bits is set to “0”,
b7
the ROM code protect is turned on, so that the contents of internal
flash memory are protected against readout and modification. The
ROM code protect is implemented in two levels. If level 2 is selected, the flash memory is protected even against readout by a
shipment inspection LSI tester, etc. When an attempt is made to
select both level 1 and level 2, level 2 is selected by default.
If both of the two ROM Code Protect Reset Bits are set to “00”, the
ROM code protect is turned off, so that the contents of internal
flash memory can be read out or modified. Once the ROM code
protect is turned on, the contents of the ROM Code Protect Reset
Bits cannot be modified in parallel I/O mode. Use the serial I/O or
CPU rewrite mode to rewrite the contents of the ROM Code Protect Reset Bits.
b0
1 1 ROM code protect control register (address FFDB16) (Note 1)
ROMCP
Reserved bits (“1” at read/write)
ROM code protect level 2 set bits (ROMCP2) (Notes 2, 3)
b3b2
0 0: Protect enabled
0 1: Protect enabled
1 0: Protect enabled
1 1: Protect disabled
ROM code protect reset bits (Note 4)
b5b4
0 0: Protect removed
0 1: Protect set bits effective
1 0: Protect set bits effective
1 1: Protect set bits effective
ROM code protect level 1 set bits (ROMCP1) (Note 2)
b7b6
0 0: Protect enabled
0 1: Protect enabled
1 0: Protect enabled
1 1: Protect disabled
Notes 1: This area is on the ROM in the mask ROM version.
2: When ROM code protect is turned on, the internal flash memory is protected
against readout or modification in parallel I/O mode.
3: When ROM code protect level 2 is turned on, ROM code readout by a shipment
inspection LSI tester, etc. also is inhibited.
4: The ROM code protect reset bits can be used to turn off ROM code protect level 1
and ROM code protect level 2. However, since these bits cannot be modified in
parallel I/O mode, they need to be rewritten in standard serial I/O mode or CPU
rewrite mode.
Fig. 63 Structure of ROM code protect control
Rev.1.01
Jul 01, 2003
page 58 of 89
7516 Group
ID Code Check Function (in Standard serial
I/O mode)
Use this function in standard serial I/O mode. When the contents
of the flash memory are not blank, the ID code sent from the programmer is compared with the ID code written in the flash memory
to see if they match. If the ID codes do not match, the commands
sent from the programmer are not accepted. The ID code consists
of 8-bit data, and its areas are FFD4 16 to FFDA16. Write a program which has had the ID code preset at these addresses to the
flash memory.
Address
FFD416
ID1
FFD516
ID2
FFD616
ID3
FFD716
ID4
FFD816
ID5
FFD916
ID6
FFDA16
ID7
FFDB16
ROM code protect control
Interrupt vector area
Fig. 64 ID code store addresses
Rev.1.01
Jul 01, 2003
page 59 of 89
7516 Group
(2) Parallel I/O Mode
Parallel I/O mode is the mode which parallel output and input software command, address, and data required for the operations
(read, program, erase, etc.) to a built-in flash memory. Use the exclusive external equipment flash programmer which supports the
7516 Group (flash memory version). Refer to each programmer
maker’s handling manual for the details of the usage.
User ROM and Boot ROM Areas
In parallel I/O mode, the user ROM and boot ROM areas shown in
Figure 57 can be rewritten. Both areas of flash memory can be operated on in the same way.
Program and block erase operations can be performed in the user ROM
area. The user ROM area and its block is shown in Figure 57.
The boot ROM area is 4 Kbytes in size. It is located at addresses
F00016 through FFFF16. Make sure program and block erase operations are always performed within this address range. (Access to any
location outside this address range is prohibited.)
In the Boot ROM area, an erase block operation is applied to only
one 4 Kbyte block. The boot ROM area has had a standard serial I/O
mode control program stored in it when shipped from the Mitsubishi
factory. Therefore, using the device in standard serial I/O mode, you
do not need to write to the boot ROM area.
Rev.1.01
Jul 01, 2003
page 60 of 89
7516 Group
(3) Standard serial I/O Mode
The standard serial I/O mode inputs and outputs the software
commands, addresses and data needed to operate (read, program, erase, etc.) the internal flash memory. This I/O is clock
synchronized serial. This mode requires the exclusive external
equipment (serial programmer).
The standard serial I/O mode is different from the parallel I/O
mode in that the CPU controls flash memory rewrite (uses the
CPU rewrite mode), rewrite data input and so forth. The standard
serial I/O mode is started by connecting “H” to the P26 (SCLK) pin
and “H” to the P41 (INT0) pin and “H” to the CNVSS pin (apply 4.5
V to 5.5 V to Vpp from an external source), and releasing the reset operation. (In the ordinary microcomputer mode, set CNVss
pin to “L” level.)
This control program is written in the Boot ROM area when the
product is shipped from Mitsubishi. Accordingly, make note of the
fact that the standard serial I/O mode cannot be used if the Boot
ROM area is rewritten in parallel I/O mode. Figure 65 shows the
pin connection for the standard serial I/O mode.
In standard serial I/O mode, serial data I/O uses the four serial I/O
pins S CLK, RxD, TxD and S RDY1 (BUSY). The SCLK1 pin is the
transfer clock input pin through which an external transfer clock is
input. The TxD pin is for CMOS output. The S RDY1 (BUSY) pin
outputs “L” level when ready for reception and “H” level when reception starts.
Serial data I/O is transferred serially in 8-bit units.
In standard serial I/O mode, only the User ROM area shown in
Figure 44 can be rewritten. The Boot ROM area cannot.
In standard serial I/O mode, a 7-byte ID code is used. When there
is data in the flash memory, commands sent from the peripheral
unit (programmer) are not accepted unless the ID code matches.
Rev.1.01
Jul 01, 2003
page 61 of 89
Outline Performance (Standard Serial I/O
Mode)
In standard serial I/O mode, software commands, addresses and
data are input and output between the MCU and peripheral units
(serial programmer, etc.) using 4-wire clock-synchronized serial
I/O (serial I/O1).
In reception, software commands, addresses and program data
are synchronized with the rise of the transfer clock that is input to
the SCLK pin, and are then input to the MCU via the RxD pin. In
transmission, the read data and status are synchronized with the
fall of the transfer clock, and output from the TxD pin.
The TxD pin is for CMOS output. Transfer is in 8-bit units with LSB
first.
When busy, such as during transmission, reception, erasing or
program execution, the SRDY1 (BUSY) pin is “H” level. Accordingly, always start the next transfer after the SRDY1 (BUSY) pin is
“L” level.
Also, data and status registers in a memory can be read after inputting software commands. Status, such as the operating state of
the flash memory or whether a program or erase operation ended
successfully or not, can be checked by reading the status register.
Here following explains software commands, status registers, etc.
7516 Group
Table 16 Description of pin function (Standard Serial I/O Mode)
P in
Name
Description
I/O
VCC,VSS
Power input
CNVSS
CNVSS
I
Connect to VCC when VCC = 4.5 V to 5.5 V.
Connect to Vpp (=4.5 V to 5.5 V) when VCC = 2.7 V to 4.5 V.
RESET
Reset input
I
Reset input pin. While reset is “L” level, a 20 cycle or longer clock
must be input to XIN pin.
X IN
Clock input
I
XOUT
Clock output
O
Connect a ceramic resonator or crystal oscillator between XIN and
XOUT pins. To input an externally generated clock, input it to XIN pin
and open XOUT pin.
AVSS
Analog power supply input
VREF
Reference voltage input
I
Enter the reference voltage for AD from this pin, or open.
P00 to P07
Input port P0
I
Input “H” or “L”, or open.
P10 to P17
Input port P1
I
Input “H” or “L”, or open.
P20 to P23
Input port P2
I
Input “H” or “L”, or open.
P24
RxD input
I
This pin is for serial data input.
P 25
TxD output
O
This pin is for serial data output.
P26
SCLK input
I
This pin is for serial clock input.
P27
BUSY output
O
This pin is for BUSY signal output.
P30 to P37
Input port P3
I
Input “H” or “L”, or open.
P40, P42 to P47
Input port P4
I
Input “H” or “L”, or open.
P41
Input port P4
I
Input “H” when RESET is released only.
Rev.1.01
Jul 01, 2003
page 62 of 89
Apply program/erase protection voltage to Vcc pin and 0 V to Vss pin.
Connect AVSS to VSS .
P11/(LED1)
P07
P10/(LED0)
P05
P06
P04
P03/SRDY2
P02/SCLK2
P01/SOUT2
P00/SIN2
P37/AN7
P36/AN6
7516 Group
25
27
26
28
29
30
31
32
33
34
35
36
VCC
VSS
P35/AN5
37
24
P12/(LED2)
P34/AN4
38
23
P13/(LED3)
P33/AN3
39
22
P14/(LED4)
P32/AN2
40
21
P15/(LED5)
P31/AN1
41
20
P16/(LED6)
P30/AN0
42
19
P17/(LED7)
VCC
43
18
VSS
VREF
44
17
XOUT
AVSS
45
16
XIN
M37516F8HP
9
10
P24/SDA2/RXD
P23/SCL1
TX D
RXD
12
8
P26/SCLK
P25/SCL2/TXD
SCLK
CNVSS
7
11
6
P27/CNTR0/SRDY1
BUSY
P22/SDA1
5
P40/CNTR1
P21/XCIN
4
13
P41/INT0
48
3
P45
P42/INT1
P20/XCOUT
1
RESET
14
2
15
47
P44/INT3/PWM
46
P43/INT2/SCMP2
P 47
P46
✽1
RESET
Value
CNVSS
P 41
4.5 to 5.5 V
SCLK
RESET
VCC ✽ 3
VCC ✽ 3
VSS
VCC
Jul 01, 2003
page 63 of 89
✽2
Notes 1: Connect oscillator circuit
2: Connect to Vcc when Vcc = 4.5 V to 5.5 V.
Connect to Vpp (=4.5 V to 5.5 V) when Vcc = 2.7 V to 4.5 V.
3: It is necessary to apply Vcc only when reset is released.
Fig. 65 Pin connection diagram in standard serial I/O mode
Rev.1.01
VPP
Signal
P41
Mode setup method
7516 Group
Software Commands (Standard Serial I/O
Mode)
commands via the RxD pin. Software commands are explained
here below.
Table 17 lists software commands. In standard serial I/O mode,
erase, program and read are controlled by transferring software
Table 17 Software commands (Standard serial I/O mode)
Control command
1st byte
transfer
2nd byte
3rd byte
4th byte
5th byte
6th byte
.....
When ID is
not verified
Address
(middle)
Address
(high)
Data
output
Data
output
Data
output
Not
acceptable
Address
(high)
Data
input
Data
input
Data
input
Data
output to
259th byte
Data input
to 259th
byte
1
Page read
FF16
2
Page program
4116
Address
(middle)
3
Erase all blocks
A716
D016
4
Read status register
7016
SRD
output
5
Clear status register
5016
6
ID code check
F516
Address
(low)
Address
(middle)
Address
(high)
ID size
ID1
Size
(high)
Checksum
Data
input
To
required
number
of times
Version
data
output
Version
data
output
Version
data
output
Version
data
output
Not
acceptable
Not
acceptable
SRD1
output
Acceptable
Not
acceptable
7
Download function
FA16
Size
(low)
8
Version data output function
FB16
Version
data
output
To ID7
Acceptable
Not
acceptable
Version
data output
to 9th byte
Acceptable
Notes1: Shading indicates transfer from the internal flash memory microcomputer to a programmer. All other data is transferred from an external equipment
(programmer) to the internal flash memory microcomputer.
2: SRD refers to status register data. SRD1 refers to status register 1 data.
3: All commands can be accepted when the flash memory is totally blank.
4: Address high must be “0016”.
Rev.1.01
Jul 01, 2003
page 64 of 89
7516 Group
●Page Read Command
This command reads the specified page (256 bytes) in the flash
memory sequentially one byte at a time. Execute the page read
command as explained here following.
(1) Transfer the “FF16” command code with the 1st byte.
(2) Transfer addresses A8 to A15 and A16 to A23 (“0016”) with the
2nd and 3rd bytes respectively.
(3) From the 4th byte onward, data (D0 to D 7) for the page (256
bytes) specified with addresses A8 to A23 will be output sequentially from the smallest address first synchronized with the
fall of the clock.
SCLK
FF16
RxD
A8 to
A15
A16 to
A23
data0
TxD
SRDY1(BUSY)
Fig. 66 Timing for page read
●Read Status Register Command
This command reads status information. When the “70 16” command code is transferred with the 1st byte, the contents of the
status register (SRD) with the 2nd byte and the contents of status
register 1 (SRD1) with the 3rd byte are read.
SCLK
RxD
TxD
SRDY1(BUSY)
Fig. 67 Timing for reading status register
Rev.1.01
Jul 01, 2003
page 65 of 89
7016
SRD
output
SRD1
output
data255
7516 Group
●Clear Status Register Command
This command clears the bits (SR4, SR5) which are set when the
status register operation ends in error. When the “5016” command
code is sent with the 1st byte, the aforementioned bits are
cleared. When the clear status register operation ends, the SRDY1
(BUSY) signal changes from “H” to “L” level.
SCLK
RxD
5016
TxD
SRDY1(BUSY)
Fig. 68 Timing for clear status register
●Page Program Command
This command writes the specified page (256 bytes) in the flash
memory sequentially one byte at a time. Execute the page program command as explained here following.
(1) Transfer the “4116” command code with the 1st byte.
(2) Transfer addresses A8 to A15 and A16 to A23 (“0016”) with the
2nd and 3rd bytes respectively.
(3) From the 4th byte onward, as write data (D0 to D 7 ) for the
page (256 bytes) specified with addresses A8 to A23 is input
sequentially from the smallest address first, that page is automatically written.
When reception setup for the next 256 bytes ends, the SRDY1
(BUSY) signal changes from “H” to “L” level. The result of the
page program can be known by reading the status register. For
more information, see the section on the status register.
SCLK
RxD
TxD
SRDY1(BUSY)
Fig. 69 Timing for page program
Rev.1.01
Jul 01, 2003
page 66 of 89
4116
A8 to
A15
A16 to
A23
data0
data255
7516 Group
●Erase All Blocks Command
This command erases the contents of all blocks. Execute the
erase all blocks command as explained here following.
(1) Transfer the “A716” command code with the 1st byte.
(2) Transfer the verify command code “D0 16” with the 2nd byte.
With the verify command code, the erase operation will start
and continue for all blocks in the flash memory.
When erase all blocks end, the S RDY1 (BUSY) signal changes
from “H” to “L” level. The result of the erase operation can be
known by reading the status register.
SCLK
RxD
TxD
SRDY1(BUSY)
Fig. 70 Timing for erase all blocks
Rev.1.01
Jul 01, 2003
page 67 of 89
A716
D016
7516 Group
●Download Command
This command downloads a program to the RAM for execution.
Execute the download command as explained here following.
(1) Transfer the “FA16” command code with the 1st byte.
(2) Transfer the program size with the 2nd and 3rd bytes.
(3) Transfer the check sum with the 4th byte. The check sum is
added to all data sent with the 5th byte onward.
(4) The program to execute is sent with the 5th byte onward.
When all data has been transmitted, if the check sum matches,
the downloaded program is executed. The size of the program will
vary according to the internal RAM.
SCLK
RxD
TxD
SRDY1(BUSY)
Fig. 71 Timing for download
Rev.1.01
Jul 01, 2003
page 68 of 89
FA16
Data size Data size
(high)
(low)
Check
sum
Program
data
Program
data
7516 Group
●Version Information Output Command
This command outputs the version information of the control program stored in the Boot ROM area. Execute the version
information output command as explained here following.
(1) Transfer the “FB16” command code with the 1st byte.
(2) The version information will be output from the 2nd byte onward. This data is composed of 8 ASCII code characters.
SCLK
RxD
FB16
TxD
SRDY1(BUSY)
Fig. 72 Timing for version information output
Rev.1.01
Jul 01, 2003
page 69 of 89
‘V’
‘E’
‘R’
‘X’
7516 Group
(1) Transfer the “F516” command code with the 1st byte.
(2) Transfer addresses A0 to A7, A8 to A15 and A16 to A23 (“0016”)
of the 1st byte of the ID code with the 2nd, 3rd, and 4th bytes
respectively.
(3) Transfer the number of data sets of the ID code with the 5th
byte.
(4) Transfer the ID code with the 6th byte onward, starting with the
1st byte of the code.
●ID Check
This command checks the ID code. Execute the boot ID check
command as explained here following.
SCLK
F516
RxD
D416
FF16
0016
ID size
TxD
SRDY1(BUSY)
Fig. 73 Timing for ID check
●ID Code
When the flash memory is not blank, the ID code sent from the serial programmer and the ID code written in the flash memory are
compared to see if they match. If the codes do not match, the
command sent from the serial programmer is not accepted. An ID
code contains 8 bits of data. Area is, from the 1st byte, addresses
FFD416 to FFDA16. Write a program into the flash memory, which
already has the ID code set for these addresses.
Address
FFD416
ID1
FFD516
ID2
FFD616
ID3
FFD716
ID4
FFD816
ID5
FFD916
ID6
FFDA16
ID7
FFDB16
ROM code protect control
Interrupt vector area
Fig. 74 ID code storage addresses
Rev.1.01
Jul 01, 2003
page 70 of 89
ID1
ID7
7516 Group
●Status Register (SRD)
The status register indicates operating status of the flash memory
and status such as whether an erase operation or a program
ended successfully or in error. It can be read by writing the read
status register command (70 16 ). Also, the status register is
cleared by writing the clear status register command (5016).
Table 18 lists the definition of each status register bit. After releasing the reset, the status register becomes “8016”.
•Sequencer status (SR7)
The sequencer status indicates the operating status of the flash
memory.
After power-on and recover from deep power down mode, the sequencer status is set to “1” (ready).
This status bit is set to “0” (busy) during write or erase operation
and is set to “1” upon completion of these operations.
•Erase status (SR5)
The erase status indicates the operating status of erase operation.
If an erase error occurs, it is set to “1”. When the erase status is
cleared, it is set to “0”.
•Program status (SR4)
The program status indicates the operating status of write operation. If a program error occurs, it is set to “1”. When the program
status is cleared, it is set to “0”.
Table 18 Definition of each bit of status register (SRD)
Definition
SRD0 bits
Status name
“1”
“0”
Ready
Busy
Reserved
Erase status
Terminated in error
Terminated normally
SR4 (bit4)
SR3 (bit3)
Program status
Reserved
Terminated in error
-
Terminated normally
-
SR2 (bit2)
SR1 (bit1)
Reserved
Reserved
-
-
SR0 (bit0)
Reserved
-
-
SR7 (bit7)
Sequencer status
SR6 (bit6)
SR5 (bit5)
Rev.1.01
Jul 01, 2003
page 71 of 89
7516 Group
●Status Register 1 (SRD1)
The status register 1 indicates the status of serial communications, results from ID checks and results from check sum
comparisons. It can be read after the status register (SRD) by writing the read status register command (7016). Also, status register
1 is cleared by writing the clear status register command (5016).
Table 19 lists the definition of each status register 1 bit. This register becomes “0016” when power is turned on and the flag status is
maintained even after the reset.
•Boot update completed bit (SR15)
This flag indicates whether the control program was downloaded
to the RAM or not, using the download function.
•Check sum consistency bit (SR12)
This flag indicates whether the check sum matches or not when a
program, is downloaded for execution using the download function.
•ID check completed bits (SR11 and SR10)
These flags indicate the result of ID checks. Some commands
cannot be accepted without an ID code check.
•Data reception time out (SR9)
This flag indicates when a time out error is generated during data
reception. If this flag is attached during data reception, the received data is discarded and the MCU returns to the command
wait state.
Table 19 Definition of each bit of status register 1 (SRD1)
SRD1 bits
SR15 (bit7)
SR14 (bit6)
Boot update completed bit
Reserved
SR13 (bit5)
SR12 (bit4)
Reserved
Checksum match bit
SR11 (bit3)
SR10 (bit2)
ID check completed bits
SR9 (bit1)
SR8 (bit0)
Rev.1.01
Jul 01, 2003
Definition
Status name
Data reception time out
Reserved
page 72 of 89
“1”
“0”
Update completed
-
Not Update
-
Match
00
01
Not verified
Verification mismatch
10
11
Reserved
Verified
Time out
-
Mismatch
Normal operation
-
7516 Group
Full Status Check
Results from executed erase and program operations can be
known by running a full status check. Figure 75 shows a flowchart
of the full status check and explains how to remedy errors which
occur.
Read status register
SR4 = 1 and
SR5 = 1 ?
YES
Command
sequence error
NO
SR5 = 0 ?
NO
Erase error
Execute the clear status register command (5016)
to clear the status register. Try performing the
operation one more time after confirming that the
command is entered correctly.
Should an erase error occur, the block in error
cannot be used.
YES
SR4 = 0 ?
NO
Program error
Should a program error occur, the block in error
cannot be used.
YES
End (Erase, program)
Note: When one of SR5 to SR4 is set to “1” , none of the program, erase all blocks
commands is accepted. Execute the clear status register command (5016) before
executing these commands.
Fig. 75 Full status check flowchart and remedial procedure for errors
Rev.1.01
Jul 01, 2003
page 73 of 89
7516 Group
Example Circuit Application for Standard
Serial I/O Mode
Figure 76 shows a circuit application for the standard serial I/O
mode. Control pins will vary according to a programmer, therefore
see a programmer manual for more information.
P41
Clock input
SCLK
BUSY output
SRDY1 (BUSY)
Data input
R XD
Data output
TXD
VPP power
source input
CNVss
M37516F8
Notes 1: Control pins and external circuitry will vary according to peripheral unit. For more
information, see the peripheral unit manual.
2: In this example, the Vpp power supply is supplied from an external source (writer). To use
the user’s power source, connect to 4.5 V to 5.5 V.
3: It is necessary to apply Vcc to SCLK pin only when reset is released.
Fig. 76 Example circuit application for standard serial I/O mode
Rev.1.01
Jul 01, 2003
page 74 of 89
7516 Group
Flash memory Electrical characteristics
Table 20 Absolute maximum ratings
Symbol
VCC
VI
VI
VI
VI
VO
VO
Pd
Topr
Tstg
Parameter
Power source voltage
Input voltage P00–P07, P10–P17, P20, P21,
P24–P27, P30–P37, P40–P47,
VREF
Input voltage P22, P23
Input voltage RESET, XIN
Input voltage CNVSS
Output voltage P00–P07, P10–P17, P20, P21,
P24–P27, P30–P37, P40–P47,
XOUT
Output voltage P22, P23
Power dissipation
Operating temperature
Storage temperature
Conditions
All voltages are based on VSS.
Output transistors are cut off.
Ta = 25 °C
Ratings
–0.3 to 6.5
Unit
V
–0.3 to VCC +0.3
V
–0.3 to 5.8
–0.3 to VCC +0.3
–0.3 to 6.5
V
V
V
–0.3 to VCC +0.3
V
–0.3 to 5.8
300
25±5
–40 to 125
V
mW
°C
°C
Table 21 Flash memory mode Electrical characteristics
(Ta = 25 oC, VCC = 4.5 to 5.5V unless otherwise noted)
Limits
Symbol
IPP1
IPP2
IPP3
VPP
VCC
Rev.1.01
Parameter
VPP power source current (read)
VPP power source current (program)
VPP power source current (erase)
VPP power source voltage
VCC power source voltage
Jul 01, 2003
page 75 of 89
Conditions
Min.
Max.
Unit
4.5
100
60
30
5.5
µA
mA
mA
V
4.5
5.5
V
3.0
3.6
V
VPP = VCC
VPP = VCC
VPP = VCC
Microcomputer mode operation at
VCC = 2.7 to 5.5V
Microcomputer mode operation at
VCC = 2.7 to 3.6V
Typ.
7516 Group
NOTES ON PROGRAMMING
Processor Status Register
A-D Converter
The contents of the processor status register (PS) after a reset are
undefined, except for the interrupt disable flag (I) which is “1.” After a reset, initialize flags which affect program execution. In
particular, it is essential to initialize the index X mode (T) and the
decimal mode (D) flags because of their effect on calculations.
The comparator uses capacitive coupling amplifier whose charge
will be lost if the clock frequency is too low.
Therefore, make sure that f(XIN) in the middle/high-speed mode is
at least on 500 kHz during an A-D conversion.
Do not execute the STP instruction or the WIT instruction during
an A-D conversion.
Interrupts
Instruction Execution Time
The contents of the interrupt request bits do not change immediately after they have been written. After writing to an interrupt
request register, execute at least one instruction before performing a BBC or BBS instruction.
The instruction execution time is obtained by multiplying the frequency of the internal clock φ by the number of cycles needed to
execute an instruction.
The number of cycles required to execute an instruction is shown
in the list of machine instructions.
The frequency of the internal clock φ is half of the XIN frequency in
high-speed mode.
Decimal Calculations
• To calculate in decimal notation, set the decimal mode flag (D)
to “1”, then execute an ADC or SBC instruction. After executing
an ADC or SBC instruction, execute at least one instruction before executing a SEC, CLC, or CLD instruction.
• In decimal mode, the values of the negative (N), overflow (V),
and zero (Z) flags are invalid.
Timers
If a value n (between 0 and 255) is written to a timer latch, the frequency division ratio is 1/(n+1).
Multiplication and Division Instructions
• The index X mode (T) and the decimal mode (D) flags do not affect the MUL and DIV instruction.
• The execution of these instructions does not change the contents of the processor status register.
Ports
The contents of the port direction registers cannot be read. The
following cannot be used:
• The data transfer instruction (LDA, etc.)
• The operation instruction when the index X mode flag (T) is “1”
• The addressing mode which uses the value of a direction register as an index
• The bit-test instruction (BBC or BBS, etc.) to a direction register
• The read-modify-write instructions (ROR, CLB, or SEB, etc.) to
a direction register.
Use instructions such as LDM and STA, etc., to set the port direction registers.
Serial I/O
In serial I/O1 (clock synchronous mode), if the receive side is using an external clock and it is to output the SRDY1 signal, set the
transmit enable bit, the receive enable bit, and the SRDY1 output
enable bit to “1.”
Serial I/O1 continues to output the final bit from the TXD pin after
transmission is completed.
SOUT2 pin for serial I/O2 goes to high impedance after transmission is completed.
When an external clock is used as synchronous clock in serial
I/O1 or serial I/O2, write transmission data to the transmit buffer
register or serial I/O2 register while the transfer clock is “H.”
Rev.1.01
Jul 01, 2003
page 76 of 89
NOTES ON USAGE
Handling of Source Pins
In order to avoid a latch-up occurrence, connect a capacitor suitable for high frequencies as bypass capacitor between power
source pin (VCC pin) and GND pin (VSS pin) and between power
source pin (VCC pin) and analog power source input pin (AVSS
pin). Besides, connect the capacitor to as close as possible. For
bypass capacitor which should not be located too far from the pins
to be connected, a ceramic capacitor of 0.01 µF–0.1µF is recommended.
EPROM Version/One Time PROM Version/
Flash Memory Version
The CNVss pin is connected to the internal memory circuit block
by a low-ohmic resistance, since it has the multiplexed function to
be a programmable power source pin (VPP pin) as well.
To improve the noise reduction, connect a track between CNVss
pin and Vss pin or Vcc pin with 1 to 10 kΩ resistance.
The mask ROM version track of CNVss pin has no operational interference even if it is connected to Vss pin or Vcc pin via a
resistor.
Electric Characteristic Differences Among
Mask ROM, Flash Memory, and One Time
PROM Version MCUs
There are differences in electric characteristics, operation margin,
noise immunity, and noise radiation among mask ROM, flash
memory, and One Time PROM version MCUs due to the differences in the manufacturing processes.
When manufacturing an application system with the flash memory,
One Time PROM version and then switching to use of the mask
ROM version, perform sufficient evaluations for the commercial
samples of the mask ROM version.
7516 Group
DATA REQUIRED FOR MASK ORDERS
ROM PROGRAMMING METHOD
The following are necessary when ordering a mask ROM production:
1. Mask ROM Order Confirmation Form✽
2. Mark Specification Form✽
3. Data to be written to ROM, in EPROM form (three identical copies) or one floppy disk.
The built-in PROM of the blank One Time PROM version and buitin EPROM version can be read or programmed with a
general-purpose PROM programmer using a special programming
adapter. Set the address of PROM programmer in the user ROM
area.
DATA REQUIRED FOR One Time PROM
PROGRAMMING ORDERS
The following are necessary when ordering a PROM programming
service:
1. ROM Programming Confirmation Form✽
2. Mark Specification Form✽ (only special mark with customer’s
trade mark logo)
3. Data to be programmed to PROM, in EPROM form (three identical copies) or one floppy disk.
✽For the mask ROM confirmation and the mark specifications, refer to the “Renesas Technology Corp.” Homepage (http://
www.renesas.com/en/rom).
Table 22 Programming adapter
Package
Name of Programming Adapter
48P6Q-A
PCA7419
The PROM of the blank One Time PROM version is not tested or
screened in the assembly process and following processes. To ensure proper operation after programming, the procedure shown in
Figure 77 is recommended to verify programming.
Programming with PROM
programmer
Screening (Caution)
(150 °C for 40 hours)
Verification with
PROM programmer
Functional check in
target device
Caution : The screening temperature is far higher
than the storage temperature. Never
expose to 150 °C exceeding 100 hours.
Fig. 77 Programming and testing of One Time PROM version
Rev.1.01
Jul 01, 2003
page 77 of 89
7516 Group
ELECTRICAL CHARACTERISTICS
Table 23 Absolute maximum ratings (Executing flash memory mode, flash memory electrical characteristics is applied.)
Symbol
VCC
VI
VI
VI
VI
VO
VO
Pd
Topr
Tstg
Parameter
Conditions
Power source voltage
Input voltage P00–P07, P10–P17, P20, P21,
P24–P27, P30–P37, P40–P47,
VREF
Input voltage P22, P23
Input voltage RESET, XIN
Input voltage M37516M4, M37516M6, M37516M8 All voltages are based on VSS.
Output transistors are cut off.
M37516E6
M37516F8
Output voltage P00–P07, P10–P17, P20, P21,
P24–P27, P30–P37, P40–P47,
XOUT
Output voltage P22, P23
Power dissipation
Ta = 25 °C
Operating temperature
Storage temperature
Ratings
–0.3 to 6.5
Unit
V
–0.3 to VCC +0.3
V
–0.3 to 5.8
–0.3 to VCC +0.3
–0.3 to VCC +0.3
–0.3 to 13
–0.3 to 6.5
V
V
–0.3 to VCC +0.3
V
–0.3 to 5.8
300
–20 to 85
–40 to 125
V
mW
°C
°C
V
Table 24 Recommended operating conditions (1)
(VCC = 2.7 to 5.5 V, Ta = –20 to 85 °C, unless otherwise noted)
Symbol
VCC
VSS
VREF
AVSS
VIA
VIH
VIH
VIH
VIH
VIH
VIH
VIL
VIL
VIL
VIL
VIL
ΣIOH(peak)
ΣIOH(peak)
ΣIOL(peak)
ΣIOL(peak)
ΣIOL(peak)
ΣIOH(avg)
ΣIOH(avg)
ΣIOL(avg)
ΣIOL(avg)
ΣIOL(avg)
Parameter
Power source voltage (At 8 MHz)
Power source voltage (At 4 MHz)
Power source voltage
A-D convert reference voltage
Analog power source voltage
Analog input voltage
AN0–AN7
“H” input voltage
P00–P07, P10–P17, P20–P27, P30–P37, P40–P47
“H” input voltage (when I2C-BUS input level is selected)
SDA1, SCL1
“H” input voltage (when I2C-BUS input level is selected)
SDA2, SCL2
“H” input voltage (when SMBUS input level is selected)
SDA1, SCL1
“H” input voltage (when SMBUS input level is selected)
SDA2, SCL2
“H” input voltage
RESET, XIN, CNVSS
“L” input voltage
P00–P07, P10–P17, P20–P27, P30–P37, P40–P47
“L” input voltage (when I2C-BUS input level is selected)
SDA1, SDA2, SCL1, SCL2
“L” input voltage (when SMBUS input level is selected)
SDA1, SDA2, SCL1, SCL2
“L” input voltage
RESET, CNVSS
“L” input voltage
XIN
“H” total peak output current
“H” total peak output current
“L” total peak output current
“L” total peak output current
“L” total peak output current
“H” total average output current
“H” total average output current
“L” total average output current
“L” total average output current
“L” total average output current
P00–P07, P10–P17, P30–P37 (Note)
P20, P21, P24–P27, P40–P47 (Note)
P00–P07, P30–P37 (Note)
P10–P17 (Note)
P20–P27,P40–P47 (Note)
P00–P07, P10–P17, P30–P37 (Note)
P20, P21, P24–P27, P40–P47 (Note)
P00–P07, P30–P37 (Note)
P10–P17 (Note)
P20–P27,P40–P47 (Note)
Min.
4.0
2.7
Limits
Typ.
5.0
5.0
0
Max.
5.5
5.5
Unit
V
0.8VCC
VCC
VCC
V
V
V
V
V
0.7VCC
5.8
V
0.7VCC
VCC
V
1.4
5.8
V
1.4
VCC
V
0.8VCC
0
VCC
0.2VCC
V
0
0.3VCC
V
0
0.6
V
0
0.2VCC
0.16VCC
V
V
–80
–80
80
120
80
–40
–40
40
60
40
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
2.0
VCC
0
AVSS
0
V
Note : The total output current is the sum of all the currents flowing through all the applicable ports. The total average current is an average value measured
over 100 ms. The total peak current is the peak value of all the currents.
Rev.1.01
Jul 01, 2003
page 78 of 89
7516 Group
Table 25 Recommended operating conditions (2)
(VCC = 2.7 to 5.5 V, Ta = –20 to 85 °C, unless otherwise noted)
Symbol
IOH(peak)
IOL(peak)
IOL(peak)
IOH(avg)
IOL(avg)
IOL(avg)
f(XIN)
f(XIN)
Parameter
“H” peak output current
P00–P07, P10–P17, P20, P21, P24–P27, P30–P37,
P40–P47 (Note 1)
“L” peak output current
P00–P07, P20–P27, P30–P37, P40–P47 (Note 1)
“L” peak output current
P10–P17 (Note 1)
“H” average output current
P00–P07, P10–P17, P20, P21, P24–P27, P30–P37,
P40–P47 (Note 2)
“L” average output current
P00–P07, P20–P27, P30–P37, P40–P47 (Note 2)
“L” peak output current
P10–P17 (Note 2)
Internal clock oscillation frequency (VCC = 4.0 to 5.5V) (Note 3)
Internal clock oscillation frequency (VCC = 2.7 to 5.5V) (Note 3)
Notes 1: The peak output current is the peak current flowing in each port.
2: The average output current IOL(avg), IOH(avg) are average value measured over 100 ms.
3: When the oscillation frequency has a duty cycle of 50%.
Rev.1.01
Jul 01, 2003
page 79 of 89
Min.
Limits
Typ.
Max.
Unit
–10
mA
10
mA
20
mA
–5
mA
5
mA
15
8
mA
MHz
4
MHz
7516 Group
Table 26 Electrical characteristics
(VCC = 2.7 to 5.5 V, VSS = 0 V, Ta = –20 to 85 °C, unless otherwise noted)
Limits
Symbol
VOH
VOL
VOL
Parameter
“H” output voltage
P00–P07, P10–P17, P20, P21,
P24–P27, P30–P37, P40–P47
(Note)
“L” output voltage
P00–P07, P20–P27, P30–P37,
P40–P47
“L” output voltage
P10–P17
Test conditions
IOH = –10 mA
VCC = 4.0–5.5 V
IOH = –1.0 mA
VCC = 2.7–5.5 V
IOL = 10 mA
VCC = 4.0–5.5 V
IOL = 1.0 mA
VCC = 2.7–5.5 V
IOL = 20 mA
VCC = 4.0–5.5 V
IOL = 10 mA
VCC = 2.7–5.5 V
Min.
Typ.
Max.
Unit
VCC–2.0
V
VCC–1.0
V
2.0
V
1.0
V
2.0
V
1.0
V
VT+–VT–
Hysteresis
CNTR0, CNTR1, INT0–INT3
0.4
V
VT+–VT–
Hysteresis
RxD, SCLK, SCIN2, SCLK2
0.5
V
0.5
V
VT+–VT–
IIH
IIH
IIH
IIL
IIL
IIL
VRAM
Hysteresis RESET
“H” input current
P00–P07, P10–P17, P20, P21,
P24–P27, P30–P37, P40–P47
“H” input current RESET, CNVSS
“H” input current XIN
“L” input current
P00–P07, P10–P17, P20–P27
P30–P37, P40–P47
“L” input current RESET,CNVSS
“L” input current XIN
RAM hold voltage
VI = VCC
5.0
µA
VI = VCC
VI = VCC
5.0
µA
µA
–5.0
µA
–5.0
µA
µA
V
4
VI = VSS
VI = VSS
VI = VSS
When clock stopped
–4
2.0
Note: P25 is measured when the P25/TXD P-channel output disable bit of the UART control register (bit 4 of address 001B16) is “0”.
Rev.1.01
Jul 01, 2003
page 80 of 89
5.5
7516 Group
Table 27 Electrical characteristics
(VCC = 2.7 to 5.5 V, VSS = 0 V, Ta = –20 to 85 °C, unless otherwise noted)
Limits
Symbol
ICC
Parameter
Power source
current
Test conditions
High-speed mode
f(XIN) = 8 MHz
f(XCIN) = 32.768 kHz
Output transistors “off”
High-speed mode
f(XIN) = 8 MHz (in WIT state)
f(XCIN) = 32.768 kHz
Output transistors “off”
Low-speed mode
Except M37516F8HP
f(XIN) = stopped
f(XCIN) = 32.768 kHz
M37516F8HP
Output transistors “off”
Low-speed mode
Except M37516F8HP
f(XIN) = stopped
f(XCIN) = 32.768 kHz (in WIT state)
M37516F8HP
Output transistors “off”
Low-speed mode (VCC = 3 V)
Except M37516F8HP
f(XIN) = stopped
f(XCIN) = 32.768 kHz
M37516F8HP
Output transistors “off”
Low-speed mode (VCC = 3 V)
Except M37516F8HP
f(XIN) = stopped
f(XCIN) = 32.768 kHz (in WIT state) M37516F8HP
Output transistors “off”
Middle-speed mode
f(XIN) = 8 MHz
f(XCIN) = stopped
Output transistors “off”
Middle-speed mode
f(XIN) = 8 MHz (in WIT state)
f(XCIN) = stopped
Output transistors “off”
Increment when A-D conversion is
executed
f(XIN) = 8 MHz
All oscillation stopped
(in STP state)
Output transistors “off”
Rev.1.01
Jul 01, 2003
page 81 of 89
Ta = 25 °C
Ta = 85 °C
Min.
Typ.
Max.
6.8
13
1.6
60
200
40
55
µA
µA
10.0
µA
µA
20
4.0
µA
µA
150
5.0
µA
µA
70
20
mA
mA
250
20
Unit
7.0
mA
1.5
mA
800
µA
0.1
1.0
µA
10
µA
7516 Group
Table 28 A-D converter characteristics
(VCC = 2.7 to 5.5 V, VSS = AVSS = 0 V, Ta = –20 to 85 °C, f(XIN) = 8 MHz, f(XCIN) = 32 kHz, unless otherwise noted)
Symbol
Parameter
–
–
tCONV
Resolution
Absolute accuracy (excluding quantization error)
Conversion time
RLADDER
IVREF
Ladder resistor
Reference power source input current
II(AD)
A-D port input current
Rev.1.01
Jul 01, 2003
page 82 of 89
Test conditions
Limits
Min.
High-speed mode,
middle-speed mode
Low-speed mode
VREF “on” VREF = 5.0 V
VREF “off”
50
Typ.
40
35
150
0.5
Unit
Max.
10
±4
61
bit
LSB
tc(φ)
200
5.0
5.0
µs
kΩ
µA
µA
µA
7516 Group
TIMING REQUIREMENTS
Table 29 Timing requirements (1)
(VCC = 4.0 to 5.5 V, VSS = 0 V, Ta = –20 to 85 °C, unless otherwise noted)
Symbol
tW(RESET)
tC(XIN)
tWH(XIN)
tWL(XIN)
tC(CNTR)
tWH(CNTR)
tWL(CNTR)
tWH(INT)
tWL(INT)
tC(SCLK1)
tWH(SCLK1)
tWL(SCLK1)
tsu(RxD-SCLK1)
th(SCLK1-RxD)
tC(SCLK2)
tWH(SCLK2)
tWL(SCLK2)
tsu(SIN2-SCLK2)
th(SCLK2-SIN2)
Parameter
Reset input “L” pulse width
External clock input cycle time
External clock input “H” pulse width
External clock input “L” pulse width
CNTR0, CNTR1 input cycle time
CNTR0, CNTR1 input “H” pulse width
CNTR0, CNTR1 input “L” pulse width
INT0 to INT3 input “H” pulse width
INT0 to INT3 input “L” pulse width
Serial I/O1 clock input cycle time (Note)
Serial I/O1 clock input “H” pulse width (Note)
Serial I/O1 clock input “L” pulse width (Note)
Serial I/O1 clock input set up time
Serial I/O1 clock input hold time
Serial I/O2 clock input cycle time
Serial I/O2 clock input “H” pulse width
Serial I/O2 clock input “L” pulse width
Serial I/O2 clock input set up time
Serial I/O2 clock input hold time
Limits
Min.
20
125
50
50
200
80
80
80
80
800
370
370
220
100
1000
400
400
200
200
Typ.
Max.
Unit
XIN cycles
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Note : When f(XIN) = 8 MHz and bit 6 of address 001A16 is “1” (clock synchronous).
Divide this value by four when f(XIN) = 8 MHz and bit 6 of address 001A16 is “0” (UART).
Table 30 Timing requirements (2)
(VCC = 2.7 to 5.5 V, VSS = 0 V, Ta = –20 to 85 °C, unless otherwise noted)
Parameter
Symbol
tW(RESET)
tC(XIN)
tWH(XIN)
tWL(XIN)
tC(CNTR)
tWH(CNTR)
tWL(CNTR)
tWH(INT)
tWL(INT)
tC(SCLK1)
tWH(SCLK1)
tWL(SCLK1)
tsu(RxD-SCLK1)
th(SCLK1-RxD)
tC(SCLK2)
tWH(SCLK2)
tWL(SCLK2)
tsu(SIN2-SCLK2)
th(SCLK2-SIN2)
Reset input “L” pulse width
External clock input cycle time
External clock input “H” pulse width
External clock input “L” pulse width
CNTR0, CNTR1 input cycle time
CNTR0, CNTR1 input “H” pulse width
CNTR0, CNTR1 input “L” pulse width
INT0 to INT3 input “H” pulse width
INT0 to INT3 input “L” pulse width
Serial I/O1 clock input cycle time (Note)
Serial I/O1 clock input “H” pulse width (Note)
Serial I/O1 clock input “L” pulse width (Note)
Serial I/O1 clock input set up time
Serial I/O1 clock input hold time
Serial I/O2 clock input cycle time
Serial I/O2 clock input “H” pulse width
Serial I/O2 clock input “L” pulse width
Serial I/O2 clock input set up time
Serial I/O2 clock input hold time
Note : When f(XIN) = 4 MHz and bit 6 of address 001A16 is “1” (clock synchronous).
Divide this value by four when f(XIN) = 8 MHz and bit 6 of address 001A16 is “0” (UART).
Rev.1.01
Jul 01, 2003
page 83 of 89
Limits
Min.
20
250
100
100
500
230
230
230
230
2000
950
950
400
200
2000
950
950
400
300
Typ.
Max.
Unit
XIN cycles
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
7516 Group
Table 31 Switching characteristics 1
(VCC = 4.0 to 5.5 V, VSS = 0 V, Ta = –20 to 85 °C, unless otherwise noted)
Parameter
Symbol
tWH (SCLK1)
tWL (SCLK1)
td (SCLK1-TXD)
tv (SCLK1-TXD)
tr (SCLK1)
tf (SCLK1)
tWH (SCLK2)
tWL (SCLK2)
td (SCLK2-SOUT2)
tv (SCLK2-SOUT2)
tf (SCLK2)
tr (CMOS)
tf (CMOS)
Test conditions
Serial I/O1 clock output “H” pulse width
Serial I/O1 clock output “L” pulse width
Serial I/O1 output delay time (Note 1)
Limits
Min.
Typ.
tC(SCLK1)/2–30
tC(SCLK1)/2–30
Max.
140
–30
Serial I/O1 output valid time (Note 1)
Serial I/O1 clock output rising time
Serial I/O1 clock output falling time
Serial I/O2 clock output “H” pulse width
Serial I/O2 clock output “L” pulse width
Serial I/O2 output delay time (Note 2)
Serial I/O2 output valid time (Note 2)
Serial I/O2 clock output falling time
CMOS output rising time (Note 3)
CMOS output falling time (Note 3)
30
30
Fig. 79
tC(SCLK2)/2–160
tC(SCLK2)/2–160
200
0
10
10
30
30
30
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Notes 1: For tWH(SCLK1), tWL(SCLK1), when the P25/TXD P-channel output disable bit of the UART control register (bit 4 of address 001B16) is “0”.
2: When the P01/SOUT2 and P02/SCLK2 P-channel output disable bit of the Serial I/O2 control register (bit 7 of address 001516) is “0”.
3: The XOUT pin is excluded.
Table 32 Switching characteristics 2
(VCC = 2.7 to 5.5 V, VSS = 0 V, Ta = –20 to 85 °C, unless otherwise noted)
Parameter
Symbol
tWH (SCLK1)
tWL (SCLK1)
td (SCLK1-TXD)
tv (SCLK1-TXD)
tr (SCLK1)
tf (SCLK1)
tWH (SCLK2)
tWL (SCLK2)
td (SCLK2-SOUT2)
tv (SCLK2-SOUT2)
tf (SCLK2)
tr (CMOS)
tf (CMOS)
Serial I/O1 clock output “H” pulse width
Serial I/O1 clock output “L” pulse width
Serial I/O1 output delay time (Note 1)
Serial I/O1 output valid time (Note 1)
Serial I/O1 clock output rising time
Serial I/O1 clock output falling time
Serial I/O2 clock output “H” pulse width
Serial I/O2 clock output “L” pulse width
Serial I/O2 output delay time (Note 2)
Serial I/O2 output valid time (Note 2)
Serial I/O2 clock output falling time
CMOS output rising time (Note 3)
CMOS output falling time (Note 3)
Test conditions
Limits
Min.
Typ.
tC(SCLK1)/2–50
tC(SCLK1)/2–50
Max.
350
–30
50
50
Fig. 79
tC(SCLK2)/2–240
tC(SCLK2)/2–240
400
0
20
20
50
50
50
Notes 1: For tWH(SCLK1), tWL(SCLK1), when the P25/TXD P-channel output disable bit of the UART control register (bit 4 of address 001B16) is “0”.
2: When the P01/SOUT2 and P02/SCLK2 P-channel output disable bit of the Serial I/O2 control register (bit 7 of address 001516) is “0”.
3: The XOUT pin is excluded.
Rev.1.01
Jul 01, 2003
page 84 of 89
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
7516 Group
MULTI-MASTER I2C-BUS BUS LINE CHARACTERISTICS
Table 33 Multi-master I2C-BUS bus line characteristics
Standard clock mode High-speed clock mode
Symbol
Parameter
Min.
Max.
Max.
Unit
tBUF
Bus free time
4.7
Min.
1.3
tHD;STA
Hold time for START condition
4.0
0.6
tLOW
Hold time for SCL clock = “0”
4.7
tR
Rising time of both SCL and SDA signals
tHD;DAT
Data hold time
tHIGH
Hold time for SCL clock = “1”
tF
Falling time of both SCL and SDA signals
tSU;DAT
Data setup time
250
100
ns
tSU;STA
Setup time for repeated START condition
4.7
0.6
µs
tSU;STO
Setup time for STOP condition
4.0
0.6
µs
µs
µs
µs
1.3
20+0.1Cb
300
ns
0
0
0.9
µs
4.0
0.6
1000
300
µs
20+0.1Cb
300
ns
Note: Cb = total capacitance of 1 bus line
SDA
tHD:STA
tBUF
tLOW
SCL
P
tR
tF
Sr
S
tHD:STA
tHD:DAT
tsu:STO
tHIGH
tsu:DAT
P
tsu:STA
S : START condition
Sr : RESTART condition
P : STOP condition
Fig. 78 Timing diagram of multi-master I2C-BUS
Rev.1.01
Jul 01, 2003
page 85 of 89
7516 Group
1 kΩ
Measurement output pin
Measurement output pin
100pF
CMOS output
Fig. 79 Circuit for measuring output switching characteristics (1)
Rev.1.01
Jul 01, 2003
page 86 of 89
100 pF
N-channnel open-drain
Fig. 80 Circuit for measuring output switching characteristics (2)
7516 Group
tC(CNTR)
tWH(CNTR)
CNTR0
CNTR1
tWL(CNTR)
0.8VCC
0.2VCC
tWL(INT)
tWH(INT)
0.8VCC
INT0 to INT3
0.2VCC
tW(RESET)
RESET
0.8VCC
0.2VCC
tC(XIN)
tWL(XIN)
tWH(XIN)
0.8VCC
XIN
SCLK1
SCLK2
tf
0.2VCC
tC(SCLK1), tC(SCLK2)
tWL(SCLK1), tWL(SCLK2)
tWH(SCLK1), tWH(SCLK2)
tr
0.8VCC
0.2VCC
tsu(RxD-SCLK1),
tsu(SIN2-SCLK2)
RXD
SIN2
0.8VCC
0.2VCC
td(SCLK1-TXD),
td(SCLK2-SOUT2)
TXD
SOUT2
Fig. 81 Timing diagram
Rev.1.01
Jul 01, 2003
th(SCLK1-RxD),
th(SCLK2-SIN2)
page 87 of 89
tv(SCLK1-TXD),
tv(SCLK2-SOUT2)
7516 Group
PACKAGE OUTLINE
MMP
48P6Q-A
EIAJ Package Code
LQFP48-P-77-0.50
Plastic 48pin 7✕7mm body LQFP
Weight(g)
–
Lead Material
Cu Alloy
MD
ME
e
JEDEC Code
–
b2
HD
D
48
37
1
I2
Recommended Mount Pad
36
E
HE
Symbol
25
12
13
24
A
F
L1
A3
A2
e
A
A1
A2
b
c
D
E
e
HD
HE
L
L1
Lp
y
b
Rev.1.01
x
Jul 01, 2003
L
Detail F
M
page 88 of 89
Lp
c
A1
A3
x
y
b2
I2
MD
ME
Dimension in Millimeters
Min
Nom
Max
1.7
–
–
0.1
0.2
0
1.4
–
–
0.17
0.22
0.27
0.105
0.125
0.175
6.9
7.0
7.1
6.9
7.0
7.1
0.5
–
–
8.8
9.0
9.2
8.8
9.0
9.2
0.35
0.5
0.65
1.0
–
–
0.45
0.6
0.75
–
0.25
–
–
–
0.08
0.1
–
–
0°
8°
–
0.225
–
–
1.0
–
–
7.4
–
–
–
–
7.4
Sales Strategic Planning Div.
Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan
Keep safety first in your circuit designs!
1. Renesas Technology Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with
them. Trouble with semiconductors may lead to personal injury, fire or property damage.
Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of
nonflammable material or (iii) prevention against any malfunction or mishap.
Notes regarding these materials
1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corporation product best suited to the customer’s application; they
do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corporation or a third party.
2. Renesas Technology Corporation assumes no responsibility for any damage, or infringement of any third-party’s rights, originating in the use of any product data, diagrams, charts,
programs, algorithms, or circuit application examples contained in these materials.
3. All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these
materials, and are subject to change by Renesas Technology Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers
contact Renesas Technology Corporation or an authorized Renesas Technology Corporation product distributor for the latest product information before purchasing a product listed
herein.
The information described here may contain technical inaccuracies or typographical errors.
Renesas Technology Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors.
Please also pay attention to information published by Renesas Technology Corporation by various means, including the Renesas Technology Corporation Semiconductor home page
(http://www.renesas.com).
4. When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information
as a total system before making a final decision on the applicability of the information and products. Renesas Technology Corporation assumes no responsibility for any damage,
liability or other loss resulting from the information contained herein.
5. Renesas Technology Corporation semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially
at stake. Please contact Renesas Technology Corporation or an authorized Renesas Technology Corporation product distributor when considering the use of a product contained
herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
6. The prior written approval of Renesas Technology Corporation is necessary to reprint or reproduce in whole or in part these materials.
7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be
imported into a country other than the approved destination.
Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited.
8. Please contact Renesas Technology Corporation for further details on these materials or the products contained therein.
http://www.renesas.com
© 2002, 2003. Renesas Technology Corp., All rights reserved. Printed in Japan.
REVISION HISTORY
Rev.
Date
Description
Summary
Page
0.1 Feb. 03, 2000
–
7516 Group Data Sheet
First edition issued
1.0 Sep. 05, 2002 1
1
2
3
4
5–6
7–9
11
15
17–87
“●Memory size” of “FEATURES” is revised.
“●Power dissipation” of “FEATURES” is revised.
Figure 2 is partly revised.
Table 1 is partly revised.
Figure 3 is added.
Clause of “GROUP EXPANSION” is added.
Clause of “CENTRAL PROCESSING UNIT (CPU)” is partly added.
Figure 8 is partly revised.
Figure 11 is partly revised.
Pages 17–87 are added.
1.01 Jul. 01, 2003 4
80
Figure 3 is partly revised.
Table 26 is partly revised.