APTDF400U120 Single diode Power Module VCES = 1200V IC = 400A @ Tc = 80°C Application • Anti-Parallel diode - Switchmode Power Supply - Inverters Snubber diode Uninterruptible Power Supply (UPS) Induction heating Welding equipment High speed rectifiers Electric vehicles • • • • • • Features A2 A S P M™ A S P M™ A1 • • • • • • Ultra fast recovery times Soft recovery characteristics Very low stray inductance High blocking voltage High current Low leakage current Benefits K2 • • • • Low losses Low noise switching Direct mounting to heatsink (isolated package) Low junction to case thermal resistance Absolute maximum ratings Symbol VR VRRM Parameter Maximum DC reverse Voltage Maximum Peak Repetitive Reverse Voltage IF(AV) Maximum Average Forward Current IF(RMS) IFSM RMS Forward Current Non-Repetitive Forward Surge Current Duty cycle = 50% Max ratings Unit 1200 V Tc = 25°C 450 Tc = 80°C 400 750 5000 Tj = 25°C A These Devices are sensitive to Electrostatic Discharge. Proper Handing Procedures Should Be Followed. APT website – http://www.advancedpower.com 1-3 APTDF400U120 – Rev 0 June, 2003 K1 APTDF400U120 All ratings @ Tj = 25°C unless otherwise specified Symbol Characteristic VF Diode Forward Voltage IRM Maximum Reverse Leakage Current CT Junction Capacitance Symbol Characteristic IF=1A,VR=30V di/dt = 15A/µs IF = 500A VR = 650V di/dt=1000A/µs Reverse Recovery Time trr3 tfr2 IRRM1 IRRM2 Qrr1 Qrr2 Vfr1 Vfr2 dIM/dt Forward Recovery Time Reverse Recovery Current IF = 500A VR = 650V di/dt=1000A/µs Reverse Recovery Charge Forward Recovery Voltage Rate of Fall of Recovery Current Torque Mounting torque Wt Package Weight Max 2.5 2.5 Typ Tj = 25°C 90 Tj = 25°C 110 Tj = 100°C 175 Tj = 25°C 220 Tj = 100°C 220 Tj = 25°C Tj = 100°C 70 120 Tj = 25°C 10 Tj = 100°C 30 Tj = 25°C 26 Tj = 100°C 26 Tj = 25°C Tj = 100°C 1200 800 Min Typ To heatsink For terminals M5 M6 APT website – http://www.advancedpower.com µA pF Max Unit ns ns A µC V A/µs Max 0.08 2500 -40 -40 -40 2.5 3 Unit V 2.0 2500 5000 Min Thermal and package characteristics Symbol Characteristic RthJC Junction to Case RMS Isolation Voltage, any terminal to case VISOL t =1 min, I isol<1mA, 50/60Hz TJ Operating junction temperature range TSTG Storage Temperature Range TC Operating Case Temperature Typ 600 Test Conditions trr1 tfr1 Min VR = 200V Dynamic Characteristics trr2 Test Conditions IF = 500A IF = 1000A IF = 500A Tj = 150°C Tj = 25°C VR = 1200V Tj = 125°C Unit °C/W V 150 125 100 3.5 4 250 °C N.m g 2-3 APTDF400U120 – Rev 0 June, 2003 Electrical Characteristics APTDF400U120 APT reserves the right to change, without notice, the specifications and information contained herein APT's products are covered by one or more of U.S patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. U.S and Foreign patents pending. All Rights Reserved. APT website – http://www.advancedpower.com 3-3 APTDF400U120 – Rev 0 June, 2003 A S P M™ A S P M™ Package outline