MBR3035PT THRU MBR30100PT 30.0 AMPS. Schottky Barrier Rectifiers Voltage Range 35 to 100 Volts Current 30.0 Amperes TO-3P/TO-247AD Features Plastic material used carries Underwriters Laboratory Classifications 94V-0 Metal silicon junction, majority carrier conduction Low power loss, high efficiency High current capability, low forward voltage drop High surge capability For use in low voltage, high frequency inverters, free wheeling, and polarity protection applications Guardring for overvoltage protection High temperature soldering guaranteed: 260oC/10 seconds,0.17”(4.3mm)from case Mechanical Data Cases: JEDEC TO-3P/TO-247AD molded plastic body Terminals: Leads solderable per MIL-STD-750, Method 2026 Polarity: As marked Mounting position: Any Mounting torque: 10 in. - lbs. max Weight: 0.2 ounce, 5.6 grams Dimensions in inches and (millimeters) Maximum Ratings and Electrical Characteristics Rating at 25℃ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% Symbol MBR MBR Type Number Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current (SEE F1G. 1) Peak Repetitive Forward Current (Rated VR, Square Wave, o 20KHz) at Tc=105 C Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method ) Peak Repetitive Reverse Surge Current (Note 2) VRRM VRMS VDC I(AV) MBR 3050 PT 50 35 50 IFSM 2.0 VF 0.60 0.76 0.72 dV/dt RθJC TJ TSTG Notes: 1. 2.0us Pulse Width, f=1.0 KHz 2. Pulse Test: 300us Pulse Width, 1% Duty Cycle 3. Thermal Resistance from Junction to case Per Leg - 198 - MBR 3090 PT 90 63 90 MBR 30100 PT 100 70 100 Units V V V 30 A 30.0 A A 1.0 A 0.85 0.75 5.0 100.0 0.75 0.65 1.0 60.0 IR Maximum Thermal Resistance Per Leg(Note 3) MBR 3060 PT 60 42 60 250 IRRM Voltage Rate of Change at (Rated VR) Storage Temperature Range 3045 PT 45 31 45 IFRM Maximum Instantaneous Forward Voltage at (Note 1) IF=15A, Tc=25OC IF=15A, Tc=125OC IF=30A, Tc=25OC IF=30A, Tc=125OC Maximum Instantaneous Reverse Current @ Tc=25℃ at Rated DC Blocking Voltage Per Leg(Note 2) @ Tc=125℃ Operating Junction Temperature Range 3035 PT 35 24 35 V 1.4 mA mA V/uS ℃/W -65 to +150 -65 to +175 ℃ ℃ 10,000 1,000 RATINGS AND CHARACTERISTIC CURVES (MBR3035PT THRU MBR30100PT) FIG.2- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER LEG FIG.1- FORWARD CURRENT DERATING CURVE 300 RESISTIVE OR INDUCTIVE LOAD PEAK FORWARD SURGE CURRENT. (A) AVERAGE FORWARD CURRENT. (A) 30 24 18 12 6 MBR3035PT-MBR3045PT MBR3050PT & MBR30100PT 0 0 50 100 Tj=Tj max. 8.3ms Single Half Sine Wave JEDEC Method 250 200 MBR 150 MBR3 50 CASE TEMPERATURE. ( C) 0100 PT 035P T-MB R 3060P T 100 NUMBER OF CYCLES AT 60Hz FIG.3- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS PER LEG FIG.4- TYPICAL REVERSE CHARACTERISTICS PER LEG 50 50 10 10 INSTANTANEOUS REVERSE CURRENT. (mA) INSTANTANEOUS FORWARD CURRENT. (A) BR3 10 o Pulse Width=300 s 1% Duty Cycle Tj=150 0C 1 Tj=25 0C 0.1 Tj=125 0C 1 Tj=75 0C 0.1 0.01 Tj=25 0C MBR3035PT-MBR3045PT MBR3050PT & MBR3060PT MBR3090PT-MBR30100PT 0.01 0.001 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 FORWARD VOLTAGE. (V) 40 60 80 100 120 140 TRANSIENT THERMAL IMPEDANCE. ( OC/W) 100 Tj=25 0C f=1.0MHz Vsig=50mVp-p 1,000 MBR3035PT-MBR3045PT MBR3050PT & MBR3060PT MBR3090PT-MBR30100PT 0.1 20 FIG.6- TYPICAL TRANSIENT THERMAL IMPEDANCE PER LEG FIG.5- TYPICAL JUNCTION CAPACITANCE PER LEG 100 MBR3035PT-MBR3045PT MBR3050PT & MBR30100PT 0 PERCENT OF RATED PEAK REVERSE VOLTAGE. (%) 5,000 JUNCTION CAPACITANCE.(pF) PT-M 100 0 1 150 3090 1 10 100 REVERSE VOLTAGE. (V) - 199 - 10.0 1 0.1 0.01 0.1 1 T, PULSE DURATION. (sec) 10 100