Hynix HYMD232M726A8-H Unbuffered ddr so-dimm Datasheet

32Mx72 bits
Unbuffered DDR SO-DIMM
HYMD232M726A(L)8-J/M/K/H/L
DESCRIPTION
Hynix HYMD232M726A(L)8-J/M/K/H/L series is unbuffered 200-pin double data rate Synchronous DRAM Small Outline Dual In-Line Memory Modules (SO-DIMMs) which are organized as 32Mx72 high-speed memory arrays. Hynix
HYMD232M726A(L)8-J/M/K/H/L series consists of nine 32Mx8 DDR SDRAM in 400mil TSOP II packages on a 200pin
glass-epoxy substrate.
Hynix HYMD232M726A(L)8-J/M/K/H/L series is designed for high speed of up to 166MHz and offers fully synchronous operations referenced to both rising and falling edges of differential clock inputs. While all addresses and control
inputs are latched on the rising edges of the clock, Data, Data strobes and Write data masks inputs are sampled on
both rising and falling edges of it. The data paths are internally pipelined and 2-bit prefetched to achieve very high
bandwidth. All input and output voltage levels are compatible with SSTL_2. High speed frequencies, programmable
latencies and burst lengths allow variety of device operation in high performance memory system.
Hynix HYMD232M726A(L)8-J/M/K/H/L series incorporates SPD(serial presence detect). Serial presence detect function is implemented via a serial 2,048-bit EEPROM. The first 128 bytes of serial PD data are programmed by Hynix to
identify DIMM type, capacity and other the information of DIMM and the last 128 bytes are available to the customer.
FEATURES
•
256MB (32M x 72) Unbuffered DDR SO-DIMM
based on 32Mx8 DDR SDRAM
•
Data inputs on DQS centers when write (centered
DQ)
•
JEDEC Standard 200-pin small outline dual in-line
memory module (SO-DIMM)
•
Data strobes synchronized with output data for read
and input data for write
•
2.5V +/- 0.2V VDD and VDDQ Power supply
•
Programmable CAS Latency 2 / 2.5 supported
•
All inputs and outputs are compatible with SSTL_2
interface
•
Programmable Burst Length 2 / 4 / 8 with both
sequential and interleave mode
•
Fully differential clock operations (CK & /CK) with
100MHz/125MHz/133MHz/166MHz
•
tRAS Lock-out function supported
•
Internal four bank operations with single pulsed RAS
•
All addresses and control inputs except Data, Data
strobes and Data masks latched on the rising edges
of the clock
•
Auto refresh and self refresh supported
•
8192 refresh cycles / 64ms
•
Data(DQ), Data strobes and Write masks latched on
both rising and falling edges of the clock
ORDERING INFORMATION
Part No.
Power Supply
Clock Frequency
HYMD232M726A(L)8-J
166MHz (*DDR333)
HYMD232M726A(L)8-M
133MHz (*DDR266:2-2-2)
HYMD232M726A(L)8-K
VDD=2.5V
VDDQ=2.5V
133MHz (*DDR266A)
HYMD232M726A(L)8-H
133MHz (*DDR266B)
HYMD232M726A(L)8-L
100MHz (*DDR200)
Interface
Form Pactor
SSTL_2
200pin Unbuffered SO-DIMM
* JEDEC Defined Specifications compliant
This document is a general product description and is subject to change without notice. Hynix Semiconductor does not assume any
responsibility for use of circuits described. No patent licenses are implied.
Rev. 0.2/Oct. 02
1
HYMD232M726A(L)8-J/M/K/H/L
PIN DESCRIPTION
Pin
Pin Description
Pin
Pin Description
CK0, /CK0, CK1, /CK1
Differential Clock Inputs
VDDQ
DQs Power Supply
CS0, CS1
Chip Select Input
VSS
Ground
CKE0, CKE1
Clock Enable Input
VREF
Reference Power Supply
/RAS, /CAS, /WE
Commend Sets Inputs
VDDSPD
Power Supply for SPD
A0 ~ A12
Address
SA0~SA2
E2PROM Address Inputs
BA0, BA1
Bank Address
SCL
E2PROM Clock
DQ0~DQ63
Data Inputs/Outputs
SDA
E2PROM Data I/O
DQS0~DQS7
Data Strobe Inputs/Outputs
VDDID
VDD Identification Flag
DM0~DM7
Data-in Mask
DU
Do not Use
VDD
Power Supply
NC
No Connection
PIN ASSIGNMENT
Pin
Name
Pin
Name
Pin
Name
Pin
1
VREF
2
VREF
51
VSS
52
3
VSS
4
VSS
53
DQ19
54
Name
Pin
Name
VSS
101
A9
Pin
Name
Pin
Name
Pin
Name
102
A8
151
DQ42
152
DQ46
DQ23
103
VSS
104
VSS
153
DQ43
154
DQ47
5
DQ0
6
DQ4
55
DQ24
56
DQ28
105
A7
106
A6
155
VDD
156
VDD
7
DQ1
8
DQ5
57
VDD
58
VDD
107
A5
108
A4
157
VDD
158
/CK1
9
VDD
10
VDD
59
DQ25
60
DQ29
109
A3
110
A2
159
VSS
160
CK1
11
DQS0
12
DM0
61
DQS3
62
DM3
111
A1
112
A0
161
VSS
162
VSS
13
DQ2
14
DQ6
63
VSS
64
VSS
113
VDD
114
VDD
163
DQ48
164
DQ52
15
VSS
16
VSS
65
DQ26
66
DQ30
115
A10/AP
116
BA1
165
DQ49
166
DQ53
17
DQ3
18
DQ7
67
DQ27
68
DQ31
117
BA0
118
/RAS
167
VDD
168
VDD
19
DQ8
20
DQ12
69
VDD
70
VDD
119
/WE
120
/CAS
169
DQS6
170
DM6
21
VDD
22
VDD
71
NC
72
NC
121
/CS0
122
/CS1
171
DQ50
172
DQ54
23
DQ9
24
DQ13
73
NC
74
NC
123
DU
124
DU
173
VSS
174
VSS
25
DQS1
26
DM1
75
VSS
76
VSS
125
VSS
126
VSS
175
DQ51
176
DQ55
27
VSS
28
VSS
77
NC
78
NC
127
DQ32
128
DQ36
177
DQ56
178
DQ60
29
DQ10
30
DQ14
79
NC
80
NC
129
DQ33
130
DQ37
179
VDD
180
VDD
31
DQ11
32
DQ15
81
VDD
82
VDD
131
VDD
132
VDD
181
DQ57
182
DQ61
33
VDD
34
VDD
83
NC
84
NC
133
DQS4
134
DM4
183
DQS7
184
DM7
35
CK0
36
VDD
85
DU
86
DU
135
DQ34
136
DQ38
185
VSS
186
VSS
37
/CK0
38
VSS
87
VSS
88
VSS
137
VSS
138
VSS
187
DQ58
188
DQ62
39
VSS
40
VSS
89
NC
90
VSS
139
DQ35
140
DQ39
189
DQ59
190
DQ63
41
DQ16
42
DQ20
91
NC
92
VDD
141
DQ40
142
DQ44
191
VDD
192
VDD
43
DQ17
44
DQ21
93
VDD
94
VDD
143
VDD
144
VDD
193
SDA
194
SA0
45
VDD
46
VDD
95
CKE1
96
CKE0
145
DQ41
146
DQ45
195
SCL
196
SA1
47
DQS2
48
DM2
97
NC
98
DU
147
DQS5
148
DM5
197 VDDSPD 198
SA2
49
DQ18
50
DQ22
99
A12
100
A11
149
VSS
150
VSS
199
DU
Rev. 0.2/Oct. 02
VDDID
200
2
HYMD232M726A(L)8-J/M/K/H/L
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Rating
Unit
Ambient Temperature
TA
0 ~ 70
o
Storage Temperature
TSTG
-55 ~ 125
oC
Voltage on Any Pin relative to VSS
VIN, VOUT
-0.5 ~ 3.6
V
Voltage on VDD relative to VSS
VDD
-0.5 ~ 3.6
V
Voltage on VDDQ relative to VSS
VDDQ
-0.5 ~ 3.6
V
Output Short Circuit Current
IOS
50
mA
Power Dissipation
PD
8
W
Soldering Temperature ⋅ Time
TSOLDER
260 / 10
oC
C
/ Sec
Note : Operation at above absolute maximum rating can adversely affect device reliability
DC OPERATING CONDITIONS (TA= 0 to 70 oC, Voltage referenced to VSS= 0V)
Parameter
Symbol
Min
Typ.
Max
Unit
Power Supply Voltage
VDD
2.3
2.5
2.7
V
Power Supply Voltage
VDDQ
2.3
2.5
2.7
V
Input High Voltage
VIH
VREF + 0.15
-
VDDQ + 0.3
V
Input Low Voltage
VIL
-0.3
-
VREF - 0.15
V
Termination Voltage
VTT
VREF - 0.04
VREF
VREF + 0.04
V
Reference Voltage
VREF
1.15
1.25
1.35
V
Note
1
2
3
Note :
1. VDDQ must not exceed the level of VDD.
2. VIL (min) is acceptable -1.5V AC pulse width with < 5ns of duration.
3. The value of VREF is approximately equal to 0.5VDDQ.
AC OPERATING CONDITIONS (TA= 0 to 70 oC, Voltage referenced to VSS= 0V)
Parameter
Symbol
Min
Input High (Logic 1) Voltage, DQ, DQS and DM signals
VIH(AC)
VREF + 0.31
Input Low (Logic 0) Voltage, DQ, DQS and DM signals
VIL(AC)
Input Differential Voltage, CK and /CK inputs
VID(AC)
Input Crossing Point Voltage, CK and /CK inputs
VIX(AC)
Max
Unit
Note
V
VREF - 0.31
V
0.7
VDDQ + 0.6
V
1
0.5*VDDQ-0.2
0.5*VDDQ+0.2
V
2
Note :
1. VID is the magnitude of the difference between the input level on CK and the input on /CK.
2. The value of V IX is expected to equal 0.5*V DDQ of the transmitting device and must track variations in the DC level of the same.
Rev. 0.2/Oct. 02
3
HYMD232M726A(L)8-J/M/K/H/L
AC OPERATING TEST CONDITIONS (TA=0 to 70oC, Voltage referenced to VSS = 0V)
Parameter
Value
Unit
Reference Voltage
VDDQ x 0.5
V
Termination Voltage
VDDQ x 0.5
V
AC Input High Level Voltage (VIH, min)
VREF + 0.31
V
AC Input Low Level Voltage (VIL, max)
VREF - 0.31
V
VREF
V
Output Timing Measurement Reference Level Voltage
VTT
V
Input Signal maximum peak swing
1.5
V
Input minimum Signal Slew Rate
1
V/ns
Termination Resistor (RT)
50
Ω
Series Resistor (RS)
25
Ω
Output Load Capacitance for Access Time Measurement (CL)
30
pF
Input Timing Measurement Reference Level Voltage
Rev. 0.2/Oct. 02
4
HYMD232M726A(L)8-J/M/K/H/L
CAPACITANCE (TA=25oC, f=100MHz )
Parameter
Pin
Symbol
Min
Max
Unit
Input Capacitance
A0 ~ A12, BA0, BA1
CIN1
TBD
TBD
pF
Input Capacitance
/RAS, /CAS, /WE
CIN2
TBD
TBD
pF
Input Capacitance
CKE0, CKE1
CIN3
TBD
TBD
pF
Input Capacitance
/CS0, /CS1
CIN4
TBD
TBD
pF
Input Capacitance
CK0, /CK0, CK1, /CK1
CIN5
TBD
TBD
pF
Input Capacitance
DM0 ~ DM7
CIN6
TBD
TBD
pF
Data Input / Output Capacitance
DQ0 ~ DQ63, DQS0 ~ DQS7
CIO1
TBD
TBD
pF
Data Input / Output Capacitance
CB0 ~ CB7
CIO2
TBD
TBD
pF
Note :
1. VDD = min. to max., VDDQ = 2.3V to 2.7V, VODC = VDDQ/2, VOpeak-to-peak = 0.2V
2. Pins not under test are tied to GND.
3. These values are guaranteed by design and are tested on a sample basis only.
OUTPUT LOAD CIRCUIT
VTT
RT=50Ω
Output
Zo=50Ω
VREF
CL=30pF
Rev. 0.2/Oct. 02
5
HYMD232M726A(L)8-J/M/K/H/L
DC CHARACTERISTICS I (TA=0 to 70oC, Voltage referenced to VSS = 0V)
Parameter
Symbol
Add, CMD, /CS, /CKE
Input Leakage Current\
Min.
Max
Unit
-18
18
uA
-4
4
1
ILI
CK, /CK
Note
Output Leakage Current
ILO
-5
5
uA
2
Output High Voltage
VOH
VTT + 0.76
-
V
IOH = -15.2mA
Output Low Voltage
VOL
-
VTT - 0.76
V
IOL = +15.2mA
Note :
1. VIN = 0 to 3.6V, All other pins are not tested under VIN =0V
2. DOUT is disabled, VOUT=0 to 2.7V
Rev. 0.2/Oct. 02
6
HYMD232M726A(L)8-J/M/K/H/L
DC CHARACTERISTICS II (TA=0 to 70oC, Voltage referenced to VSS = 0V)
Parameter
Symbol
Test Condition
Speed
Unit Note
-J
-M
-K
-H
-L
IDD0
One bank; Active - Precharge;
tRC=tRC(min); tCK=tCK(min); DQ,DM and
DQS inputs changing twice per clock cycle ;
address and control inputs changing once per
clock cycle
945
945
855
855
810
mA
1
Operating Current
IDD1
One bank; Active - Read - Precharge; Burst
Length=2; tRC=tRC(min); tCK=tCK(min);
address and control inputs changing once per
clock cycle
1350
1350
1170
1170
1080
mA
1
Precharge Power
Down Standby
Current
IDD2P
All banks idle; Power down - mode;
CKE=Low, tCK=tCK(min)
mA
1
Idle Standby Current
IDD2F
/CS=High, All banks idle; tCK=tCK(min);
CKE= High; address and control inputs
changing once per clock cycle. VIN=VREF
for DQ, DQS and DM
mA
1
Active Power Down
Standby Current
IDD3P
One bank active; Power down mode;
CKE=Low, tCK=tCK(min)
225
mA
1
Idle Quiet Standby
Current
IDD2Q
/CS>=Vih(min); All banks idle;
CKE>=Vih(min); Addresses and other control
inputs stable, Vin=Vref for DQ, DQS and DM
TBD
mA
IDD3N
/CS=HIGH; CKE=HIGH; One bank; ActivePrecharge; tRC=tRAS(max); tCK=tCK(min);
DQ, DM and DQS inputs changing twice per
clock cycle; Address and other control inputs
changing once per clock cycle
540
540
450
450
450
IDD4R
Burst=2; Reads; Continuous burst; One bank
active; Address and control inputs changing
once per clock cycle; tCK=tCK(min);
IOUT=0mA
2610
2610
2250
2250
1710
IDD4W
Burst=2; Writes; Continuous burst; One bank
active; Address and control inputs changing
once per clock cycle; tCK=tCK(min); DQ, DM
and DQS inputs changing twice per clock
cycle
2610
2610
2250
2250
1710
2070
2070
1890
1890
1755
Operating Current
Active Standby
Current
Operating Current
Operating Current
Auto Refresh Current
IDD5
tRC=tRFC(min) - 8*tCK for DDR200 at
100Mhz, 10*tCK for DDR266A & DDR266B
at 133Mhz; distributed refresh
Self Refresh Current
IDD6
CKE=<0.2V; External clock on;
tCK =tCK(min)
Operating Current Four Bank Operation
IDD7
Four bank interleaving with BL=4 Refer to the
following page for detailed test condition
IDD7A
4banks active read with activate every 20ns,
AP(Auto Precharge) read every 20ns, BL=4,
tRCD=3, IOUT=0 mA, 100% DQ, DM and
DQS inputs changing twice per clock cycle;
100% addresses changing once per clock
cycle
Random Read
Current
Rev. 0.2/Oct. 02
180
450
450
360
360
315
mA
1
1
mA
1
1
Normal
27
mA
1
Low Power
13.5
mA
1
mA
1
2835
2835
2745
TBD
2745
2520
mA
7
HYMD232M726A(L)8-J/M/K/H/L
AC CHARACTERISTICS (AC operating conditions unless otherwise noted)
DDR333
Parameter
<DDR333, DDR266(2-2-2)>
DDR266(2-2-2)
Symbol
Unit
Min
Max
Min
Max
Row Cycle Time
tRC
60
-
60
-
ns
Auto Refresh Row Cycle Time
tRFC
72
-
75
-
ns
Row Active Time
tRAS
42
70K
45
120K
ns
Active to Read with Auto Precharge Delay
tRAP
18
-
15
-
ns
Row Address to Column Address Delay
tRCD
18
-
15
-
ns
Row Active to Row Active Delay
tRRD
12
-
15
-
ns
Column Address to Column Address Delay
tCCD
1
-
1
-
CK
Row Precharge Time
tRP
18
-
15
-
ns
Write Recovery Time
tWR
15
-
15
-
ns
Write to Read Command Delay
tWTR
1
-
1
-
CK
Auto Precharge Write Recovery + Precharge Time
tDAL
(tWR/tCK)
+
(tRP/tCK)
-
(tWR/tCK)
+
(tRP/tCK)
-
CK
6
12
7.5
12
ns
7.5
12
7.5
12
ns
CL = 2.5
System Clock Cycle Time
Note
16
15
tCK
CL = 2
Clock High Level Width
tCH
0.45
0.55
0.45
0.55
CK
Clock Low Level Width
tCL
0.45
0.55
0.45
0.55
CK
Data-Out edge to Clock edge Skew
tAC
-0.7
0.7
-0.75
0.75
ns
DQS-Out edge to Clock edge Skew
tDQSCK
-0.6
0.6
-0.75
0.75
ns
DQS-Out edge to Data-Out edge Skew
tDQSQ
-
0.45
-
0.5
ns
Data-Out hold time from DQS
tQH
tHP
-tQHS
-
tHP
-tQHS
-
ns
1, 10
Clock Half Period
tHP
min
(tCL,tCH)
-
min
(tCL,tCH)
-
ns
1,9
tQHS
-
0.55
-
0.75
ns
10
Data Hold Skew Factor
Valid Data Output Window
tDV
Data-out high-impedance window from CK, /CK
tHZ
-0.7
0.7
-0.75
0.75
ns
17
Data-out low-impedance window from CK, /CK
tLZ
-0.7
0.7
-0.75
0.75
ns
17
Input Setup Time (fast slew rate)
tIS
0.75
-
0.9
-
ns
2,3,5,6
Input Hold Time (fast slew rate)
tIH
0.75
-
0.9
-
ns
2,3,5,6
Input Setup Time (slow slew rate)
tIS
0.8
-
1.0
-
ns
2,4,5,6
Input Hold Time (slow slew rate)
tIH
0.8
-
1.0
-
ns
2,4,5,6
tIPW
2.2
ns
6
tDQSH
0.35
Input Pulse Width
Write DQS High Level Width
Rev. 0.2/Oct. 02
tQH-tDQSQ
tQH-tDQSQ
ns
2.2
-
0.35
-
CK
8
HYMD232M726A(L)8-J/M/K/H/L
AC CHARACTERISTICS (AC operating conditions unless otherwise noted)
DDR333
Parameter
- continued DDR266(2-2-2)
Symbol
Unit
Min
Max
Min
Max
Note
Write DQS Low Level Width
tDQSL
0.35
-
0.35
-
CK
Clock to First Rising edge of DQS-In
tDQSS
0.75
1.25
0.72
1.28
CK
Data-In Setup Time to DQS-In (DQ & DM)
tDS
0.45
-
0.5
-
ns
6,7, 11~13
Data-in Hold Time to DQS-In (DQ & DM)
tDH
0.45
-
0.5
-
ns
6,7, 11~13
DQ & DM Input Pulse Width
tDIPW
1.75
-
1.75
-
ns
Read DQS Preamble Time
tRPRE
0.9
1.1
0.9
1.1
CK
Read DQS Postamble Time
tRPST
0.4
0.6
0.4
0.6
CK
Write DQS Preamble Setup Time
tWPRES
0
-
0
-
CK
Write DQS Preamble Hold Time
tWPREH
0.25
-
0.25
-
CK
Write DQS Postamble Time
tWPST
0.4
0.6
0.4
0.6
CK
Mode Register Set Delay
tMRD
2
-
2
-
CK
Exit Self Refresh to Any Execute Command
tXSC
200
-
200
-
CK
Average Periodic Refresh Interval
tREFI
-
15.6
-
15.6
us
Rev. 0.2/Oct. 02
8
9
HYMD232M726A(L)8-J/M/K/H/L
AC CHARACTERISTICS
(AC operating conditions unless otherwise noted)
DDR266A
Parameter
<DDR266A/B, DDR200>
DDR266B
DDR200
Symbol
Unit
Min
Max
Min
Max
Min
Max
Row Cycle Time
tRC
65
-
65
-
70
-
ns
Auto Refresh Row Cycle Time
tRFC
75
-
75
-
80
-
ns
Row Active Time
tRAS
45
120K
45
120K
50
120k
ns
Active to Read with Auto Precharge Delay
tRAP
20
-
20
-
20
-
ns
Row Address to Column Address Delay
tRCD
20
-
20
-
20
-
ns
Row Active to Row Active Delay
tRRD
15
-
15
-
15
-
ns
Column Address to Column Address Delay
tCCD
1
-
1
-
1
-
CK
Row Precharge Time
tRP
20
-
20
-
20
-
ns
Write Recovery Time
tWR
15
-
15
-
15
-
ns
Write to Read Command Delay
tWTR
1
-
1
-
1
-
CK
Auto Precharge Write Recovery + Precharge
Time
tDAL
(tWR/tCK)
+
(tRP/tCK)
-
(tWR/tCK)
+
(tRP/tCK)
-
(tWR/tCK)
+
(tRP/tCK)
-
CK
7.5
12
7.5
12
8.0
12
ns
7.5
12
10
12
10
12
ns
CL = 2.5
System Clock Cycle Time
Note
16
15
tCK
CL = 2
Clock High Level Width
tCH
0.45
0.55
0.45
0.55
0.45
0.55
CK
Clock Low Level Width
tCL
0.45
0.55
0.45
0.55
0.45
0.55
CK
Data-Out edge to Clock edge Skew
tAC
-0.75
0.75
-0.75
0.75
-0.8
0.8
ns
DQS-Out edge to Clock edge Skew
tDQSCK
-0.75
0.75
-0.75
0.75
-0.8
0.8
ns
DQS-Out edge to Data-Out edge Skew
tDQSQ
-
0.5
-
0.5
-
0.6
ns
Data-Out hold time from DQS
tQH
tHP
-tQHS
-
tHP
-tQHS
-
tHP
-tQHS
-
ns
1, 10
Clock Half Period
tHP
min
(tCL,tCH
)
-
min
(tCL,tCH
)
-
min
(tCL,tCH
)
-
ns
1,9
tQHS
-
0.75
-
0.75
-
0.75
ns
10
Data Hold Skew Factor
Valid Data Output Window
tDV
Data-out high-impedance window from CK, /CK
tHZ
-0.75
0.75
-0.75
0.75
-0.8
0.8
ns
17
Data-out low-impedance window from CK, /CK
tLZ
-0.75
0.75
-0.75
0.75
-0.8
0.8
ns
17
Input Setup Time (fast slew rate)
tIS
0.9
-
0.9
-
1.1
-
ns
2,3,5,6
Input Hold Time (fast slew rate)
tIH
0.9
-
0.9
-
1.1
-
ns
2,3,5,6
Input Setup Time (slow slew rate)
tIS
1.0
-
1.0
-
1.1
-
ns
2,4,5,6
Input Hold Time (slow slew rate)
tIH
1.0
-
1.0
-
1.1
-
ns
2,4,5,6
tIPW
2.2
2.5
-
ns
6
tDQSH
0.35
0.35
-
CK
Input Pulse Width
Write DQS High Level Width
Rev. 0.2/Oct. 02
tQH-tDQSQ
tQH-tDQSQ
2.2
-
0.35
-
tQH-tDQSQ
ns
10
HYMD232M726A(L)8-J/M/K/H/L
- continued DDR266A
Parameter
DDR266B
DDR200
Symbol
Unit
Min
Max
Min
Max
Min
Max
Write DQS Low Level Width
tDQSL
0.35
-
0.35
-
0.35
-
CK
Clock to First Rising edge of DQS-In
tDQSS
0.75
1.25
0.75
1.25
0.72
1.28
CK
Data-In Setup Time to DQS-In (DQ & DM)
tDS
0.45
-
0.45
-
0.5
-
ns
Data-in Hold Time to DQS-In (DQ & DM)
tDH
0.45
-
0.45
-
0.5
-
ns
DQ & DM Input Pulse Width
tDIPW
1.75
-
1.75
-
1.75
-
ns
Read DQS Preamble Time
tRPRE
0.9
1.1
0.9
1.1
0.9
1.1
CK
Read DQS Postamble Time
tRPST
0.4
0.6
0.4
0.6
0.4
0.6
CK
Write DQS Preamble Setup Time
tWPRES
0
-
0
-
0
-
CK
Write DQS Preamble Hold Time
tWPREH
0.25
-
0.25
-
0.25
-
CK
Write DQS Postamble Time
tWPST
0.4
0.6
0.4
0.6
0.4
0.6
CK
Mode Register Set Delay
tMRD
2
-
2
-
2
-
CK
Exit Self Refresh to Any Execute Command
tXSC
200
-
200
-
200
-
CK
Average Periodic Refresh Interval
tREFI
-
15.6
-
15.6
-
15.6
us
Rev. 0.2/Oct. 02
Note
6,7,
11~13
8
11
HYMD232M726A(L)8-J/M/K/H/L
Note :
1.
This calculation accounts for tDQSQ(max), the pulse width distortion of on-chip circuit and jitter.
2.
Data sampled at the rising edges of the clock : A0~A12, BA0~BA1, CKE, /CS, /RAS, /CAS, /WE.
3.
For command/address input slew rate >=1.0V/ns
4.
For command/address input slew rate >=0.5V/ns and <1.0V/ns
This derating table is used to increase tIS/tIH in case where the input slew-rate is below 0.5V/ns.
Input Setup / Hold Slew-rate Derating Table.
Input Setup / Hold Slew-rate
Delta tIS
Delta tIH
V/ns
ps
ps
0.5
0
0
0.4
+50
0
0.3
+100
0
5.
CK, /CK slew rates are >=1.0V/ns
6.
These parameters quarantee device timing, but they are not necessarily tested on each device, and they may be quaranteed by
design or tester correlation.
7.
Data latched at both rising and falling edges of Data Strobes(LDQS/UDQS) : DQ, LDM/UDM.
8.
Minimum of 200 cycles of stable input clocks after Self Refresh Exit command, where CKE is held high, is required to complete
Self Refresh Exit and lock the internal DLL circuit of DDR SDRAM.
9.
Min (tCL, tCH) refers to the smaller of the actual clock low time and the actual clock high time as provided to the device
(i.e. this value can be greater than the minimum specification limits for tCL and tCH).
10.
tHP = minimum half clock period for any given cycle and is defined by clock high or clock low (tCH, tCL). tQHS consists of
tDQSQmax, the pulse width distortion of on-chip clock circuits, data pin to pin skew and output pattern effects and p-channel
to n-channel variation of the output drivers.
11.
This derating table is used to increase tDS/tDH in case where the input slew-rate is below 0.5V/ns.
Input Setup / Hold Slew-rate Derating Table.
12.
Input Setup / Hold Slew-rate
Delta tDS
Delta tDH
V/ns
ps
ps
0.5
0
0
0.4
+75
+75
0.3
+150
+150
I/O Setup/Hold Plateau Derating. This derating table is used to increase tDS/tDH in case where the input level is flat below
VREF +/-310mV for a duration of up to 2ns.
I/O Input Level
13.
Delta tDS
Delta tDH
mV
ps
ps
+280
+50
+50
I/O Setup/Hold Delta Inverse Slew Rate Derating. This derating table is used to increase tDS/tDH in case where the DQ and
DQS slew rates differ. The Delta Inverse Slew Rate is calculated as (1/SlewRate1)-(1/SlewRate2). For example, if slew rate
1=0.5V/ns and Slew Rate2 = 0.4V/n then the Delta Inverse Slew Rate = -0.5ns/V.
(1/SlewRate1)-(1/SlewRate2)
Delta tDS
Delta tDH
ns/V
ps
ps
Rev. 0.2/Oct. 02
0
0
0
+/-0.25
+50
+50
+/- 0.5
+100
+100
12
HYMD232M726A(L)8-J/M/K/H/L
14.
DQS, DM and DQ input slew rate is specified to prevent double clocking of data and preserve setup and hold times.
Signal transi tions through the DC region must be monotonic.
15.
tDAL = (tDPL / tCK ) + (tRP / tCK ). For each of the terms above, if not already an integer, round to the next highest integer.
tCK is equal to the actual system clock cycle time.
Example: For DDR266B at CL=2.5 and tCK = 7.5 ns,
tDAL = (15 ns / 7.5 ns) + (20 ns / 7.5 ns) = (2.00) + (2.67)
Round up each non-integer to the next highest integer: = (2) + (3), tDAL = 5 clock
16.
For the parts which do not has internal RAS lockout circuit, Active to Read with Auto precharge delay should be
tRAS - BL/2 x tCK.
17.
tHZ and tLZ transitions occur in the same access time windows as valid data trasitions. These parameters are not referenced
to a specific voltage level but specify when the device output is no longer driving (HZ), or begins driving (LZ).
Rev. 0.2/Oct. 02
13
HYMD232M726A(L)8-J/M/K/H/L
SIMPLIFIED COMMAND TRUTH TABLE
A10/
AP
Command
CKEn-1
CKEn
/CS
/RAS
/CAS
/WE
Extended Mode Register Set
H
X
L
L
L
L
OP code
1,2
Mode Register Set
H
X
L
L
L
L
OP code
1,2
H
X
X
X
H
X
X
1
L
H
H
H
Device Deselect
No Operation
Bank Active
H
X
L
L
H
H
H
X
L
H
L
H
ADDR
RA
Read
BA
V
L
CA
Read with Autoprecharge
1
1,3
L
H
X
L
H
L
L
CA
Write with Autoprecharge
1
V
H
Precharge All Banks
H
X
L
L
H
L
Precharge selected Bank
1
V
H
Write
Note
1,4
H
X
1,5
L
V
1
X
Read Burst Stop
H
X
L
H
H
L
X
1
Auto Refresh
H
H
L
L
L
H
X
1
Entry
H
L
L
L
L
H
H
X
X
X
Exit
L
H
L
H
H
H
H
X
X
X
L
H
H
H
Self Refresh
Precharge
Power Down
Mode
Active Power
Down Mode
(Clock Suspend)
Entry
H
1
X
1
1
L
1
X
Exit
Entry
Exit
L
H
L
H
X
X
X
1
L
H
H
H
1
H
X
X
X
1
L
V
V
V
H
L
H
X
X
1
1
( H=Logic High Level, L=Logic Low Level, X=Don’t Care, V=Valid Data Input, OP Code=Operand Code, NOP=No Operation )
Note :
1. LDM/UDM states are Don’t Care. Refer to below Write Mask Truth Table.
2. OP Code(Operand Code) consists of A0~A12 and BA0~BA1 used for Mode Registering duing Extended MRS or MRS.
Before entering Mode Register Set mode, all banks must be in a precharge state and MRS command can be issued after tRP
period from Prechagre command.
3. If a Read with Autoprecharge command is detected by memory component in CK(n), then there will be no command presented
to activated bank until CK(n+BL/2+tRP).
4. If a Write with Autoprecharge command is detected by memory compoment in CK(n), then there will be no command presented
to activated bank until CK(n+BL/2+1+tDPL+tRP). Last Data-In to Prechage delay(tDPL) which is also called Write Recovery Time
(tWR) is needed to guarantee that the last data has been completely written.
5. If A10/AP is High when Row Precharge command being issued, BA0/BA1 are ignored and all banks are selected to be
precharged.
Rev. 0.2/Oct. 02
14
SERIAL PRESENCE DETECT
SPD SPECIFICATION
(32Mx72 Unbuffered DDR SO-DIMM)
Rev. 0.2/Oct. 02
16
HYMD232M726A(L)8-J/M/K/H/L
SERIAL PRESENCE DETECT
Byte#
Function Description
0
Number of Bytes written into serial memory at module
manufacturer
1
Total number of Bytes in SPD device
2
Fundamental memory type
3
4
5
6
7
Module data width (continued)
Bin Sort :J(DDR333),M(DDR266(2-2-2)),K(DDR266A@CL=2)
H(DDR266B@CL=2.5),L(DDR200@CL=2)
Function Supported
J
M
K
H
Hexa Value
L
J
M
128 Bytes
K
L
Note
80h
256 Bytes
08h
DDR SDRAM
07h
Number of row address on this assembly
13
0Dh
1
Number of column address on this assembly
10
0Ah
1
Number of physical banks on DIMM
1Bank
01h
Module data width
72 Bits
48h
-
00h
8
Module voltage Interface levels(VDDQ)
9
DDR SDRAM cycle time at CAS Latency=2.5(tCK)
10
DDR SDRAM access time from clock at CL=2.5 (tAC) +/-0.7ns
11
Module configuration type
12
Refresh rate and type
13
Primary DDR SDRAM width
14
Error checking DDR SDRAM data width
15
Minimum clock delay for back-to-back random column address(tCCD)
SSTL 2.5V
6.0ns
7.5ns
7.5ns
04h
7.5ns
+/-0.75ns
8.0ns
60h
75h
75h
75h
80h
2
+/-0.8ns
70h
75h
75h
75h
80h
2
2
ECC
02h
7.8us & Self refresh
82h
x8
08h
x8
08h
1 CLK
01h
2,4,8
0Eh
16
Burst lengths supported
17
Number of banks on each DDR SDRAM
18
CAS latency supported
19
CS latency
0
01h
20
WE latency
1
02h
21
DDR SDRAM module attributes
Differential Clock Input
20h
+/-0.2Voltage tolerance,
Concurrent Auto Precharge
tRAS Lock Out
C0h
22
H
DDR SDRAM device attributes : General
23
DDR SDRAM cycle time at CL=2.0(tCK)
24
DDR SDRAM access time from clock at CL=2.0(tAC) +/-0.7ns
7.5ns
25
DDR SDRAM cycle time at CL=1.5(tCK)
26
DDR SDRAM access time from clock at CL=1.5(tAC)
27
Minimum row precharge time(tRP)
7.5ns
4 Banks
04h
2, 2.5
0Ch
7.5ns
10ns
+/-0.75ns
10ns
75h
75h
75h
A0h
A0h
+/-0.8ns
70h
75h
75h
75h
80h
-
00h
18ns
15ns
00h
20ns
20ns
20ns
2
48h
3Ch
50h
50h
50h
3Ch
28
Minimum row activate to row active delay(tRRD)
12ns
15ns
15ns
15ns
15ns
30h
3Ch
3Ch
3Ch
29
Minimum RAS to CAS delay(tRCD)
18ns
15ns
20ns
20ns
20ns
48h
3Ch
50h
50h
50h
30
Minimum active to precharge time(tRAS)
42ns
45ns
45ns
45ns
50ns
2Ah
2Dh
2Dh
2Dh
32h
31
Module row density
32
Command and address signal input setup time(tIS)
0.75ns
0.9ns
0.9ns
0.9ns
1.1ns
75h
90h
90h
90h
B0h
33
Command and address signal input hold time(tIH)
0.75ns
0.9ns
0.9ns
0.9ns
1.1ns
75h
90h
90h
90h
B0h
34
Data signal input setup time(tDS)
0.45ns
0.5ns
0.5ns
0.5ns
0.6ns
45h
50h
50h
50h
60h
35
Data signal input hold time(tDH)
0.45ns
0.5ns
0.5ns
0.5ns
0.6ns
45h
50h
50h
50h
60h
256MB
36~40 Reserved for VCSDRAM
40h
Undefined
00h
41
Minimum active / auto-refresh time ( tRC)
60ns
60ns
65ns
65ns
70ns
3Ch
3Ch
41h
41h
46h
42
Minimum auto-refresh to active/auto-refresh
command period(tRFC)
72ns
75ns
75ns
75ns
80ns
48h
4Bh
4Bh
4Bh
50h
43
Maximum cycle time (tCK max)
12ns
12ns
12ns
12ns
12ns
30h
30h
30h
30h
30h
44
Maximim DQS-DQ skew time(tDQSQ)
0.45ns
0.5ns
0.5ns
0.5ns
0.6ns
2Dh
32h
32h
32h
3Ch
45
Maximum read data hold skew factor(tQHS)
0.55ns
0.75ns
0.75ns
0.75ns
0.75ns
55h
75h
75h
75h
75h
F4h
8Eh
46~61 Superset information(may be used in future)
62
SPD Revision code
63
Checksum for Bytes 0~62
Rev. 0.2/Oct. 02
Undefined
00h
Initial release
-
2
2
00h
12h
9Ch
C9h
17
HYMD232M726A(L)8-J/M/K/H/L
SERIAL PRESENCE DETECT
Byte #
64
65~71
- continued Function Supported
Function Description
J
M
Manufacturer JEDEC ID Code
K
H
Hexa Value
L
J
M
K
Hynix JEDEC ID
ADh
-
00h
Hynix(Korea Area)
HSA(United States Area)
HSE(Europe Area)
HSJ(Japan Area)
Singapore
Asia Area
0*h
1*h
2*h
3*h
4*h
5*h
--------- Manufacturer JEDEC ID Code
72
Manufacturing location
73
Manufacture part number(Hynix Memory Module)
H
48h
74
-------- Manufacture part number(Hynix Memory Module)
Y
59h
75
-------- Manufacture part number(Hynix Memory Module)
M
4Dh
76
Manufacture part number (DDR SDRAM)
D
44h
77
Manufacture part number(Memory density)
2
32h
78
Manufacture part number(Module Depth)
3
33h
79
------- Manufacture part number(Module Depth)
2
32h
80
Manufacture part number(Module type)
M
4Dh
81
Manufacture part number(Data width)
7
37h
82
-------Manufacture part number(Data width)
2
32h
83
Manufacture part number(Refresh, # of Bank.)
84
Manufacture part number(Component Generation)
6(8K refresh,4Bank)
36h
A
41h
85
Manufacture part number(Component configuration)
8
38h
86
Manufacture part number(Hyphen)
‘-’
2Dh
87
Manufacture part number(Minimum cycle time)
88~90
J
M
Manufacture part number(T.B.D)
K
H
L
4Ah
4Dh
4Bh
Blank
20h
-
H
L
Not
e
6
48h
4Ch
91
Manufacture revision code(for Component)
-
92
Manufacture revision code (for PCB)
-
-
93
Manufacturing date(Year)
-
-
94
Manufacturing date(Week)
-
-
3
95~98
Module serial number
-
-
4
99~127
Manufacturer specific data (may be used in future)
Undefined
00h
5
Undefined
00h
5
128~255 Open for customer use
3
Note :
1. The bank address is excluded
2. These value is based on the component specification
3. These bytes are programmed by code of date week & date year
4. These bytes apply to Hynix’s own Module Serial Number system
5. These bytes undefined and coded as ‘00h’
6. Refer to Hynix web site
Byte 85~86, Low power part
Byte #
85
86
Function Description
Manufacture part number(Low power part)
Manufacture part number(Component configuration)
Rev. 0.2/Oct. 02
Function Supported
J
M
K
L
8
H
L
Hexa Value
J
M
K
H
L
Note
4Ch
38h
18