bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com System-Side Impedance Track™ Fuel Gauge With Integrated LDO Check for Samples: bq27520-G2 1 INTRODUCTION 1.1 FEATURES 1.2 • Battery Fuel Gauge for 1-Series Li-Ion Applications • Resides on System Main Board – Works With Embedded or Removable Battery Packs • Uses PACK+, PACK–, and T Battery Terminals • Microcontroller Peripheral Provides: – Accurate Battery Fuel Gauging – Internal Temperature Sensor for Battery Temperature Reporting – Battery Low Interrupt Warning – Battery Insertion Indicator – Configurable Level of State of Charge (SOC) Interrupts – State of Health Indicator – Current Data Logging Buffer – 32 Bytes of Non-Volatile Scratch-Pad FLASH • Battery Fuel Gauge Based on Patented Impedance Track™ Technology – Models the Battery Discharge Curve for Accurate Time-to-Empty Predictions – Automatically Adjusts for Battery Aging, Battery Self-Discharge, and Temperature/Rate Inefficiencies – Low-Value Sense Resistor (10 mΩ or Less) • 400-kHz I2C™ Interface for Connection to System Microcontroller Port • In a 15-Pin NanoFree™ (CSP) Packaging • • • • • 123 APPLICATIONS Smartphones PDAs Digital Still and Video Cameras Handheld Terminals MP3 or Multimedia Players 1.3 DESCRIPTION The Texas Instruments bq27520-G2 system-side Li-Ion battery fuel gauge is a microcontroller peripheral that provides fuel gauging for single-cell Li-Ion battery packs. The device requires little system microcontroller firmware development. The bq27520-G2 resides on the system’s main board and manages an embedded battery (non-removable) or a removable battery pack. The bq27520-G2 uses the patented Impedance Track™ algorithm for fuel gauging, and provides information such as remaining battery capacity (mAh), state-of-charge (%), run-time to empty (min), battery voltage (mV), temperature (°C) and state of health (%). Battery fuel gauging with the bq27520-G2 requires only PACK+ (P+), PACK– (P–), and Thermistor (T) connections to a removable battery pack or embedded battery circuit. The CSP option is a 15-ball package in the nominal dimensions of 2610 × 1956 µm with 0,5 mm lead pitch. It is ideal for space constrained applications. TYPICAL APPLICATION Host System Single Cell Li-lon Battery Pack VCC LDO CE Power Management Controller I2C PACK+ Battery Low Voltage Sense DATA Temp Sense PROTECTION IC T bq27520 BAT_GD PACK- FETs CHG DSG Current Sense SOC_INT 1 2 3 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Impedance Track, NanoFree are trademarks of Texas Instruments. I2C is a trademark of NXP B.V. Corp Netherlands. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2011, Texas Instruments Incorporated bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. 1 2 3 ......................................... 1.1 FEATURES .......................................... 1.2 APPLICATIONS ...................................... 1.3 DESCRIPTION ....................................... DEVICE INFORMATION ................................ 2.1 AVAILABLE OPTIONS ............................... 2.2 THERMAL INFORMATION .......................... 2.3 PIN ASSIGNMENT .................................. ELECTRICAL SPECIFICATIONS ..................... 3.1 ABSOLUTE MAXIMUM RATINGS .................. 3.2 RECOMMENDED OPERATING CONDITIONS ..... 3.3 POWER-ON RESET ................................. 3.4 2.5V LDO REGULATOR ............................. INTRODUCTION 1 1 3 3 3 5 5 6 6 HIGH-FREQUENCY OSCILLATOR DATA FLASH MEMORY CHARACTERISTICS ..... 8 I2C-COMPATIBLE INTERFACE COMMUNICATION TIMING CHARACTERISTICS ....................... 8 ............................. 9 DATA COMMANDS ................................ 10 DATA FLASH INTERFACE ........................ 19 MANUFACTURER INFORMATION BLOCK ....... 21 GENERAL DESCRIPTION 4.1 4.2 4.3 ACCESS MODES 21 4.5 SEALING/UNSEALING DATA FLASH 21 6 8 24 25 27 32 32 CHARGING AND CHARGE-TERMINATION INDICATION ........................................ 32 ................................... ................................ 5.9 AUTOCALIBRATION ............................... APPLICATION-SPECIFIC INFORMATION ......... POWER MODES 33 5.8 POWER CONTROL 34 6.1 BATTERY PROFILE STORAGE AND SELECTION 6.2 APPLICATION-SPECIFIC FLOW AND CONTROL ...................................................... ...................................................... 7 22 24 5.7 6 7 INTEGRATING ADC (COULOMB COUNTER) CHARACTERISTICS ................................ 7 ADC (TEMPERATURE AND CELL MEASUREMENT) CHARACTERISTICS ............ 7 3.10 3.11 .................................. ............. 4.6 DATA FLASH SUMMARY .......................... FUNCTIONAL DESCRIPTION ........................ 5.1 FUEL GAUGING ................................... 5.2 IMPEDANCE TRACK™ VARIABLES .............. 5.3 DETAILED PIN DESCRIPTION .................... 5.4 TEMPERATURE MEASUREMENT ................ 5.5 OVERTEMPERATURE INDICATION .............. 4.4 5.6 5 3.6 ................. LOW-FREQUENCY OSCILLATOR .................. 5 3 INTERNAL TEMPERATURE SENSOR CHARACTERISTICS ................................ 6 3.9 2 1 3.5 3.7 3.8 4 1 35 35 35 36 COMMUNICATIONS 7.1 I2C INTERFACE 7.2 I2C Time Out 7.3 I2C Command Waiting Time 7.4 I2C Clock Stretching REFERENCE SCHEMATICS 8.1 SCHEMATIC 8.2 Package Dimensions Contents Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 2 DEVICE INFORMATION 2.1 AVAILABLE OPTIONS PART NUMBER FIRMWARE VERSION PACKAGE (1) TA COMMUNICATION FORMAT 3.11 CSP-15 –40°C to 85°C I2C bq27520YZFR-G2 bq27520YZFT-G2 (1) 3000 250 For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI website at www.ti.com. 2.2 THERMAL INFORMATION bq27520-G2 THERMAL METRIC (1) YZF(15 PINS) θJA Junction-to-ambient thermal resistance 70 θJCtop Junction-to-case (top) thermal resistance 17 θJB Junction-to-board thermal resistance 20 ψJT Junction-to-top characterization parameter 1 ψJB Junction-to-board characterization parameter 18 Junction-to-case (bottom) thermal resistance n/a θJCbot (1) 2.3 TAPE and REEL QUANTITY UNITS °C/W For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953 PIN ASSIGNMENT CSP-15 (BOTTOM VIEW) CSP-15 (TOP VIEW) A3 B3 C3 D3 E3 E3 D3 C3 B3 A3 A2 B2 C2 D2 E2 E2 D2 C2 B2 A2 A1 B1 C1 D1 E1 E1 D1 C1 B1 A1 DEVICE INFORMATION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 3 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Table 2-1. PIN FUNCTIONS PIN NAME NO. TYPE (1) DESCRIPTION SRP A1 IA Analog input pin connected to the internal coulomb counter where SRP is nearest the PACK– connection. Connect to 5-mΩ to 20-mΩ sense resistor. SRN B1 IA Analog input pin connected to the internal coulomb counter where SRN is nearest the Vss connection. Connect to 5-mΩ to 20-mΩ sense resistor. VSS C1, C2 P Device ground VCC D1 P Regulator output and bq27520-G2 processor power. Decouple with 1μF ceramic capacitor to Vss. REGIN E1 P Regulator input. Decouple with 0.1μF ceramic capacitor to Vss. SOC_INT A2 O SOC state interrupts output. Generates a pulse under the conditions specified by Table 5-6. Open drain output. BAT_GD B2 O Battery-good indicator. Active-low by default, though polarity can be configured through the [BATG_POL] bit of Operation Configuration. Push-pull output. CE D2 I Chip Enable. Internal LDO is disconnected from REGIN when driven low. BAT E2 I Cell-voltage measurement input. ADC input. Recommend 4.8V maximum for conversion accuracy. SCL A3 I Slave I2C serial communications clock input line for communication with system (Master). Use with 10kΩ pull-up resistor (typical). SDA B3 I/O Slave I2C serial communications data line for communication with system (Master). Open-drain I/O. Use with 10kΩ pull-up resistor (typical). BAT_LOW C3 O Battery Low output indicator. Active high by default, though polarity can be configured through the [BATL_POL] bit of Operation Configuration. Push-pull output. TS D3 IA Pack thermistor voltage sense (use 103AT-type thermistor). ADC input. BI/TOUT E3 I/O Battery-insertion detection input. Power pin for pack thermistor network. Thermistor-multiplexer control pin. Use with pull-up resistor >1MΩ (1.8 MΩ typical). (1) 4 I/O = Digital input/output, IA = Analog input, P = Power connection DEVICE INFORMATION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 3 ELECTRICAL SPECIFICATIONS 3.1 ABSOLUTE MAXIMUM RATINGS over operating free-air temperature range (unless otherwise noted) (1) PARAMETER VALUE UNIT VREGIN Regulator input range –0.3 to 5.5 V VCC Supply voltage range –0.3 to 2.75 V VIOD Open-drain I/O pins (SDA, SCL, SOC_INT) –0.3 to 5.5 V VBAT BAT input pin VI Input voltage range to all other pins (BI/TOUT, TS, SRP, SRN, BAT_GD) ESD –0.3 to 5.5 Human-body model (HBM), BAT pin –0.3 to VCC + 0.3 V 1.5 Human-body model (HBM), all other pins kV 2 TA Operating free-air temperature range –40 to 85 °C TF Functional temperature range –40 to 100 °C Tstg Storage temperature range –65 to 150 °C (1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 3.2 RECOMMENDED OPERATING CONDITIONS TA = 25°C and VREGIN = VBAT = 3.6V (unless otherwise noted) PARAMETER TEST CONDITIONS No operating restrictions VREGIN Supply voltage CREGIN External input capacitor for internal LDO between REGIN and VSS CLDO25 External output capacitor for internal LDO between VCC and VSS ICC Normal operating-mode current (1) ISLP+ No FLASH writes MIN TYP MAX 2.7 4.5 2.45 2.7 UNIT V 0.1 μF 1 μF Fuel gauge in NORMAL mode. ILOAD > Sleep Current 118 μA Sleep+ operating mode current (1) Fuel gauge in SLEEP+ mode. ILOAD < Sleep Current 62 μA ISLP Low-power storage-mode current (1) Fuel gauge in SLEEP mode. ILOAD < Sleep Current 23 μA IHIB Hibernate operating-mode current (1) Fuel gauge in HIBERNATE mode. ILOAD < Hibernate Current 8 μA VOL Output voltage, low (SCL, SDA, SOC_INT, BAT_LOW) IOL = 3 mA VOH(PP) Output voltage, high (BAT_LOW, BAT_GD) IOH = –1 mA VCC – 0.5 VOH(OD) Output voltage, high (SDA, SCL, SOC_INT) External pullup resistor connected to VCC VCC – 0.5 Nominal capacitor values specified. Recommend a 5% ceramic X5R type capacitor located close to the device. Input voltage, low (SDA, SCL) VIL Input voltage, low (BI/TOUT) BAT INSERT CHECK MODE active Input voltage, high (SDA, SCL) VIH(OD) Input voltage, high (BI/TOUT) BAT INSERT CHECK MODE active 0.47 0.4 V V V –0.3 0.6 –0.3 0.6 1.2 6 1.2 VCC + 0.3 V VA1 Input voltage range (TS) VSS – 0.125 2 V VA2 Input voltage range (BAT) VSS – 0.125 5 V VA3 Input voltage range (SRP, SRN) VSS – 0.125 0.125 V Ilkg Input leakage current (I/O pins) tPUCD Power-up communication delay (1) 0.3 250 μA ms Specified by design. Not production tested. ELECTRICAL SPECIFICATIONS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 5 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 3.3 www.ti.com POWER-ON RESET TA = –40°C to 85°C, typical values at TA = 25°C and VREGIN = 3.6 V (unless otherwise noted) PARAMETER TEST CONDITIONS VIT+ Positive-going battery voltage input at VCC VHYS Power-on reset hysteresis 3.4 MIN TYP MAX UNIT 2.09 2.20 2.31 V 45 115 185 mV 2.5V LDO REGULATOR TA = 25°C, CLDO25 = 1μF, VREGIN = 3.6V (unless otherwise noted) PARAMETER TEST CONDITION MIN NOM MAX UNIT 2.5 2.54 V 2.5 V LDO REGULATOR (1) VREG25 Regulator output voltage VIH(CE) CE High-level input voltage VIL(CE) CE Low-level input voltage VDO Regulator dropout voltage ΔVREGTEMP ΔVREGLINE ΔVREGLOAD ISHORT (1) (2) (2) 2.7V ≤ VREGIN ≤ 4.5V, IOUT ≤ 16mA TA = –40°C to 85°C 2.4 2.45V ≤ VREGIN < 2.7V (low battery), IOUT ≤ 3mA TA = –40°C to 85°C 2.4 VREGIN = 2.7 to 4.5V TA = –40°C to 85°C V 2.65 V 0.8 2.7V, IOUT ≤ 16mA TA = –40°C to 85°C 325 2.45V, IOUT ≤ 3mA TA = –40°C to 85°C 50 Regulator output change with temperature VREGIN = 3.6V, IOUT = 16mA TA = –40°C to 85°C Line regulation 2.7V ≤ VREGIN ≤ 4.5V, IOUT = 16mA 18 40 0.2mA ≤ IOUT ≤ 3mA, VREGIN = 2.45 V 34 40 3mA ≤ IOUT ≤ 16mA, VREGIN = 2.7 V 31 Load regulation Short circuit current limit 0.5% TA = –40°C to 85°C VREG25 = 0V mV mV mV 250 mA LDO output current, IOUT, is the sum of internal and external load currents. Assured by design. Not production tested. 3.5 INTERNAL TEMPERATURE SENSOR CHARACTERISTICS TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER GTEMP 3.6 TEST CONDITIONS MIN TYP MAX UNIT –2 Temperature sensor voltage gain mV/°C HIGH-FREQUENCY OSCILLATOR TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS fOSC Operating frequency fEIO Frequency error (1) tSXO (1) (2) (3) 6 (2) MIN TYP MAX 2.097 MHz TA = 0°C to 60°C –2% 0.38% TA = –20°C to 70°C –3% 0.38% 3% TA = –40°C to 85°C –4.5% 0.38% 4.5% 2.5 5 Start-up time (3) UNIT 2% ms The frequency error is measured from 2.097 MHz. The frequency drift is included and measured from the trimmed frequency at VCC = 2.5 V, TA = 25°C. The start-up time is defined as the time it takes for the oscillator output frequency to be within ±3% of typical oscillator frequency. ELECTRICAL SPECIFICATIONS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 3.7 LOW-FREQUENCY OSCILLATOR TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER fLOSC MIN TYP Operating frequency Frequency error (1) fLEIO tLSXO (1) (2) (3) TEST CONDITIONS Start-up time MAX UNIT 32.768 (2) kHz TA = 0°C to 60°C –1.5% 0.25% 1.5% TA = –20°C to 70°C –2.5% 0.25% 2.5% TA = –40°C to 85°C –4% 0.25% 4% (3) μs 500 The frequency drift is included and measured from the trimmed frequency at VCC = 2.5 V, TA = 25°C. The frequency error is measured from 32.768 kHz. The start-up time is defined as the time it takes for the oscillator output frequency to be within ±3% of typical oscillator frequency. 3.8 INTEGRATING ADC (COULOMB COUNTER) CHARACTERISTICS TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS VSR Input voltage range, V(SRN) and V(SRP) VSR = V(SRN) – V(SRP) tSR_CONV Conversion time Single conversion MIN Input offset INL Integral nonlinearity error ZIN(SR) Effective input resistance (1) Ilkg(SR) Input leakage current (1) (1) MAX UNIT 0.125 V 1 Resolution VOS(SR) TYP –0.125 s 14 15 bits μV 10 ±0.007 ±0.034 % FSR 2.5 MΩ 0.3 μA Specified by design. Not tested in production. 3.9 ADC (TEMPERATURE AND CELL MEASUREMENT) CHARACTERISTICS TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER VIN(ADC) Input voltage range tADC_CONV Conversion time TEST CONDITIONS MIN Resolution VOS(ADC) ZADC1 Effective input resistance (BAT) (1) Ilkg(ADC) Input leakage current (1) bq27520-G2 measuring cell voltage V ms 15 bits mV 8 bq27520-G2 not measuring cell voltage UNIT 125 1 (1) ZADC2 (1) MAX 1 14 Input offset Effective input resistance (TS) TYP 0.05 MΩ 8 MΩ 100 kΩ 0.3 μA Specified by design. Not tested in production. ELECTRICAL SPECIFICATIONS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 7 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 3.10 www.ti.com DATA FLASH MEMORY CHARACTERISTICS TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER tDR Data retention TEST CONDITIONS MIN (1) Flash-programming write cycles (1) TYP MAX UNIT 10 Years 20,000 Cycles tWORDPROG Word programming time (1) ICCPROG Flash-write supply current (1) tDFERASE Data flash master erase time (1) 200 ms tIFERASE Instruction flash master erase time (1) 200 ms tPGERASE Flash page erase time (1) 20 ms (1) 5 2 ms 10 mA Specified by design. Not production tested I2C-COMPATIBLE INTERFACE COMMUNICATION TIMING CHARACTERISTICS 3.11 TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT 300 ns 300 ns tr SCL/SDA rise time tf SCL/SDA fall time tw(H) SCL pulse duration (high) 600 ns tw(L) SCL pulse duration (low) 1.3 μs tsu(STA) Setup for repeated start 600 ns td(STA) Start to first falling edge of SCL 600 ns tsu(DAT) Data setup time 100 ns th(DAT) Data hold time 0 ns tsu(STOP) Setup time for stop t(BUF) Bus free time between stop and start fSCL Clock frequency 600 ns 66 μs 400 kHz Figure 3-1. I2C-Compatible Interface Timing Diagrams 8 ELECTRICAL SPECIFICATIONS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4 GENERAL DESCRIPTION The bq27520-G2 accurately predicts the battery capacity and other operational characteristics of a single Li-based rechargeable cell. It can be interrogated by a system processor to provide cell information, such as time-to-empty (TTE), time-to-full (TTF) and state-of-charge (SOC) as well as SOC interrupt signal to the host. Information is accessed through a series of commands, called Standard Commands. Further capabilities are provided by the additional Extended Commands set. Both sets of commands, indicated by the general format Command( ), are used to read and write information contained within the device control and status registers, as well as its data flash locations. Commands are sent from system to gauge using the bq27520-G2’s I2C serial communications engine, and can be executed during application development, pack manufacture, or end-equipment operation. Cell information is stored in the device in non-volatile flash memory. Many of these data flash locations are accessible during application development. They cannot, generally, be accessed directly during end-equipment operation. Access to these locations is achieved by either use of the bq27520-G2’s companion evaluation software, through individual commands, or through a sequence of data-flash-access commands. To access a desired data flash location, the correct data flash subclass and offset must be known. The bq27520-G2 provides a 32-byte user-programmable data flash Manufacturer Info Block. This data space is accessed through a data flash interface. For specifics on accessing the data flash, see Section 4.3: MANUFACTURER INFORMATION BLOCKS. The key to the bq27520-G2’s high-accuracy gas gauging prediction is Texas Instrument’s proprietary Impedance Track™ algorithm. This algorithm uses cell measurements, characteristics, and properties to create state-of-charge predictions that can achieve less than 1% error across a wide variety of operating conditions and over the lifetime of the battery. The device measures charge/discharge activity by monitoring the voltage across a small-value series sense resistor (5 mΩ to 20 mΩ typ.) located between the system’s Vss and the battery’s PACK- terminal. When a cell is attached to the device, cell impedance is computed, based on cell current, cell open-circuit voltage (OCV), and cell voltage under loading conditions. The device external temperature sensing is optimized with the use of a high accuracy negative temperature coefficient (NTC) thermistor with R25 = 10.0kΩ ±1%. B25/85 = 3435K ± 1% (such as Semitec NTC 103AT). Alternatively, the bq27520-G2 can also be configured to use its internal temperature sensor or receive temperature data from the host processor. When an external thermistor is used, a 18.2k pull up resistor between BT/TOUT and TS pins is also required. The bq27520-G2 uses temperature to monitor the battery-pack environment, which is used for fuel gauging and cell protection functionality. To minimize power consumption, the device has different power modes: NORMAL, SLEEP+, SLEEP, HIBERNATE, and BAT INSERT CHECK. The bq27520-G2 passes automatically between these modes, depending upon the occurrence of specific events, though a system processor can initiate some of these modes directly. More details can be found in see Section 5.7: POWER MODES. NOTE FORMATTING CONVENTIONS IN THIS DOCUMENT: Commands: italics with parentheses and no breaking spaces, e.g., RemainingCapacity( ) Data flash: italics, bold, and breaking spaces, e.g., Design Capacity Register bits and flags: brackets and italics, e.g., [TDA] Data flash bits: brackets, italics and bold, e.g., [LED1] Modes and states: ALL CAPITALS, e.g., UNSEALED mode. GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 9 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 4.1 www.ti.com DATA COMMANDS 4.1.1 STANDARD DATA COMMANDS The bq27520-G2 uses a series of 2-byte standard commands to enable system reading and writing of battery information. Each standard command has an associated command-code pair, as indicated in Table 4-1. Because each command consists of two bytes of data, two consecutive I2C transmissions must be executed both to initiate the command function, and to read or write the corresponding two bytes of data. Additional options for transferring data, such as spooling, are described in Section of Communication. Standard commands are accessible in NORMAL operation. Read/Write permissions depend on the active access mode, SEALED or UNSEALED (for details on the SEALED and UNSEALED states, see Section 4.4 , Access Modes.) Table 4-1. Standard Commands NAME COMMAND CODE UNITS SEALED ACCESS Control( ) CNTL 0x00 / 0x01 N/A R/W AtRate( ) AR 0x02 / 0x03 mA R/W AtRateTimeToEmpty( ) ARTTE 0x04 / 0x05 Minutes R Temperature( ) TEMP 0x06 / 0x07 0.1 K R/W Voltage( ) VOLT 0x08 / 0x09 mV R Flags( ) FLAGS 0x0a / 0x0b N/A R NominalAvailableCapacity( ) NAC 0x0c / 0x0d mAh R FullAvailableCapacity( ) FAC 0x0e / 0x0f mAh R RemainingCapacity( ) RM 0x10 / 0x11 mAh R FullChargeCapacity( ) FCC 0x12 / 0x13 mAh R AI 0x14 / 0x15 mA R TimeToEmpty( ) TTE 0x16 / 0x17 Minutes R TimeToFull( ) TTF 0x18 / 0x19 Minutes R SI 0x1a / 0x1b mA R STTE 0x1c / 0x1d Minutes R AverageCurrent( ) StandbyCurrent( ) StandbyTimeToEmpty( ) MaxLoadCurrent( ) MLI 0x1e / 0x1f mA R MLTTE 0x20 / 0x21 Minutes R AvailableEnergy( ) AE 0x22 / 0x23 mWh R AveragePower( ) AP 0x24 / 0x25 mW R TTECP 0x26 / 0x27 Minutes R SOH 0x28 / 0x29 % / num R CC 0x2A / 0x2B num R StateOfCharge( ) SOC 0x2c / 0x2d % R NormalizedImpedanceCal( ) NIC 0x2e / 0x2f mohm R InstantaneousCurrent Reading( ) ICR 0x30 / 0x31 mA R DataLogindex( ) DLI 0x32 / 0x33 N/A R DataLogBuffer( ) DLB 0x34 / 0x35 mA R InternalTemperature( ) ITEMP 0x36 / 0x37 0.1 K R OperationConfiguration( ) OPCFG 0x3A / 0x3B N/A R MaxLoadTimeToEmpty( ) TTEatConstantPower( ) StateOfHealth( ) CycleCount( ) 10 GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.1.1.1 Control( ): 0x00/0x01 Issuing a Control( ) command requires a subsequent 2-byte subcommand. These additional bytes specify the particular control function desired. The Control( ) command allows the system to control specific features of the bq27520-G2 during normal operation and additional features when the device is in different access modes, as described in Table 4-2. Table 4-2. Control( ) Subcommands CNTL DATA SEALED ACCESS CONTROL_STATUS 0x0000 Yes Reports the status of DF checksum, hibernate, IT, etc. DEVICE_TYPE 0x0001 Yes Reports the device type (eg: 0x0520) FW_VERSION 0x0002 Yes Reports the firmware version on the device type PREV_MACWRITE 0x0007 Yes Returns previous MAC subcommand code CHEM_ID 0x0008 Yes Reports the chemical identifier of the Impedance Track™ configuration OCV_CMD 0x000c Yes Request the gauge to take a OCV measurement BAT_INSERT 0x000d Yes Forces the BAT_DET bit set when the [BIE] bit is 0 BAT_REMOVE 0x000e Yes Forces the BAT_DET bit clear when the [BIE] bit is 0 SET_HIBERNATE 0x0011 Yes Forces CONTROL_STATUS [HIBERNATE] to 1 CLEAR_HIBERNATE 0x0012 Yes Forces CONTROL_STATUS [HIBERNATE] to 0 SET_SLEEP+ 0x0013 Yes Forces CONTROL_STATUS [SNOOZE] to 1 CLEAR_SLEEP+ 0x0014 Yes Forces CONTROL_STATUS [SNOOZE] to 0 FACTORY_RESTORE 0x0015 No Forces a Factory Restore of learned resistance and Qmax to defaults ENABLE_DLOG 0x0018 Yes Commands the device to start coulomb counter Data Logging Mode. DISABLE_DLOG 0x0019 Yes Commands the device to stop Data Logging Mode. DF_VERSION 0x001F Yes Returns theData Flash Versioncode SEALED 0x0020 No Places the bq27520-G2 in SEALED access mode IT_ENABLE 0x0021 No Enables the Impedance Track™ algorithm IT_DISABLE 0x0023 No Disables the Impedance Track™ algorithm RESET 0x0041 No Forces a full reset of the bq27520-G2 CNTL FUNCTION DESCRIPTION GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 11 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.1.1.1.1 CONTROL_STATUS: 0x0000 Instructs the fuel gauge to return status information to control addresses 0x00/0x01. The status word includes the following information. Table 4-3. CONTROL_STATUS Bit Definitions High byte Low byte bit7 DLOGEN INITCOMP bit6 FAS HIBERNATE bit5 SS SNOOZE bit4 CSV SLEEP bit3 CCA LDMD bit2 BCA RUP_DIS bit1 OCVCMDCOMP VOK bit0 OCVFAIL QEN DLOGEN = Status biting the bq27520-G2 is in current Data Logging Mode. True when set. FAS = Status bit indicating the bq27520-G2 is in FULL ACCESS SEALED state. Active when set. SS = Status bit indicating the bq27520-G2 is in SEALED state. Active when set. CSV = Status bit indicating a valid data flash checksum has been generated. Active when set. CCA = Status bit indicating the bq27520-G2 Coulomb Counter Calibration routine is active. The CCA routine will take place approximately 1 minute after the initialization. Active when set. BCA = Status bit indicating the bq27520-G2 board calibration routine is active. Active when set. OCVCMDCOMP = Status bit indicating the bq27520-G2 has executed the OCV command. This bit can only be set with battery’s presence. True when set. OCVFAIL = Status bit indicating bq27520-G2 OCV reading is failed due to the current. This bit can only be set with battery’s presence. True when set. INITCOMP = Initialization completion bit indicating the initialization completed. This bit can only be set with battery’s presence. True when set. HIBERNATE = Status bit indicating a request for entry into HIBERNATE from SLEEP mode. True when set. Default is 0. SNOOZE = Status bit indicating the bq27520-G2 SLEEP+ mode is enabled. True when set. SLEEP = Status bit indicating the bq27520-G2 is in SLEEP mode. True when set. LDMD = Status bit indicating the bq27520-G2 Impedance Track™ algorithm is using constant-power mode. True when set. Default is 0 (constant-current mode). RUP_DIS = Status bit indicating the bq27520-G2 Ra table updates are disabled. Updates disabled when set. VOK = Status bit indicating the bq27520-G2 voltages are okay for Qmax updates and calculations. True when set. QEN = Status bit indicating the bq27520-G2 Qmax updates enabled. True when set. 4.1.1.1.2 DEVICE_TYPE: 0x0001 Instructs the fuel gauge to return the device type to addresses 0x00/0x01. The bq27520-G2 device type returned is 0x0520. 4.1.1.1.3 FW_VERSION: 0x0002 Instructs the fuel gauge to return the firmware version to addresses 0x00/0x01.The bq27520-G2 firmware version returned is 0x0311. 4.1.1.1.4 PREV_MACWRITE: 0x0007 Instructs the fuel gauge to return the previous subcommand written to addresses 0x00/0x01. Note: This subcommand is only supported for previous subcommand codes 0x0000 through 0x0014. For subcommand codes greater than 0x0009, a value of 0x0007 is returned. 4.1.1.1.5 CHEM_ID: 0x0008 Instructs the fuel gauge to return the chemical identifier for the Impedance Track™ configuration to addresses 0x00/0x01. 4.1.1.1.6 OCV_CMD: 0X000C This command is to request the gauge to take an Open Circuit Voltage (OCV) reading. This command can only be issued after the [INITCOMP] has been set, indicating the initialization has been completed. The OCV measurement takes place at the beginning of the next repeated 1s firmware synchronization clock and the SOC_INT pin will pulse for approximately 165mS to indicate the measurement window. For a valid OCV reading, the host should reduce the system load current below a C/20 rate within 8ms after the leading edge of SOC_INT assertion and maintain the reduced load for the remaining 165mS window. The OCV command [OCVFAIL] bit will be set if the OCV_CMD is issued when [CHG_INH] is set. 12 GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.1.1.1.7 BAT_INSERT: 0X000D This command is to force the BAT_DET bit to be set when the battery insertion detection is disabled. When the BIE is set to 0, the battery insertion detection is disabled. The gauge relies on the host to inform if of the battery insertion with this command to set the BAT_DET bit. 4.1.1.1.8 BAT_REMOVE: 0X000E This command is to force the BAT_DET bit to be clear when the battery insertion detection is disabled. When the BIE is set to 0, the battery insertion detection is disabled. The gauge relies on the host to inform if of the battery removal with this command to clear the BAT_DET bit. 4.1.1.1.9 SET_HIBERNATE: 0x0011 Instructs the fuel gauge to force the CONTROL_STATUS [HIBERNATE] bit to 1. This will allow the gauge to enter the HIBERNATE power mode after the transition to SLEEP power state is detected. The [HIBERNATE] bit is automatically cleared upon exiting from HIBERNATE mode. 4.1.1.1.10 CLEAR_HIBERNATE: 0x0012 Instructs the fuel gauge to force the CONTROL_STATUS [HIBERNATE] bit to 0. This prevents the gauge from entering the HIBERNATE power mode after the transition to the SLEEP power state is detected. It can also be used to force the gauge out of HIBERNATE mode. 4.1.1.1.11 ENABLE SLEEP+ MODE: 0X0013 Instructs the fuel gauge to set the CONTROL_STATUS [SNOOZE] bit to 1. This will enable the SLEEP+ mode. The gauge will enter SLEEP+ power mode after the transition conditions are meet. 4.1.1.1.12 DISABLE SLEEP+ MODE: 0X0014 Instructs the fuel gauge to set the CONTROL_STATUS [SNOOZE] bit to 0. This will disable the SLEEP+ mode. The gauge will exit from the SLEEP+ power mode after the SNOOZE bit is cleared. 4.1.1.1.13 FACTORY RESTORE: 0X0015 Instructs the fuel gauge to reset learned resistance tables and Qmax values to the default values. If Operation Configuration B [INDFACRES] is set, SOC_INT is asserted while the restore is in progress. This command is only available when the fuel gauge is UNSEALED. 4.1.1.1.14 ENABLE_DLOG: 0x0018 Commands the fuel gauge to set the CONTROL_STATUS[DLOGEN] bit to 1, clear the data FIFO, and begin recording coulomb counter data logging. While in Data Logging Mode, the device will not enter Sleep mode. 4.1.1.1.15 DISABLE_DLOG: 0x0019 Commands the fuel gauge to clear the CONTROL_STATUS[DLOGEN] bit to 0 and stop recording coulomb counter data. The previous data stored in the FIFO is not cleared. 4.1.1.1.16 DF_VERSION: 0x001F Instructs the fuel gauge to return the 16-bit data flash revision code to addresses 0x00/0x01. The code is stored in Data Flash Version and provides a simple method for the customer to control data flash revisions. The default DF_VERSION is 0x0000 as configured in data flash. 4.1.1.1.17 SEALED: 0x0020 Instructs the fuel gauge to transition from the UNSEALED state to the SEALED state. The fuel gauge must always be set to the SEALED state for use in end equipment. GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 13 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.1.1.1.18 IT_ENABLE: 0x0021 This command forces the fuel gauge to begin the Impedance Track™ algorithm, sets the IT Enable to 0x01 and causes the [VOK] and [QEN] flags to be set in the CONTROL_STATUS register. [VOK] is cleared if the voltages are not suitable for a Qmax update. This command is only available when the fuel gauge is UNSEALED. 4.1.1.1.19 IT_DISABLE: 0x0023 This command disables the fuel gauge the Impedance Track™ algorithm, clears the IT Enable to 0x00 and causes the [QEN] flags to be cleared in the CONTROL_STATUS register. This command is only available when the fuel gauge is UNSEALED. 4.1.1.1.20 RESET: 0x0041 This command instructs the fuel gauge to perform a full reset. This command is only available when the fuel gauge is UNSEALED. 4.1.1.2 AtRate( ): 0x02/0x03 The AtRate( ) read-/write-word function is the first half of a two-function command set used to set the AtRate value used in calculations made by the AtRateTimeToEmpty( ) function. The AtRate( ) units are in mA. The AtRate( ) value is a signed integer, with negative values interpreted as a discharge current value. The AtRateTimeToEmpty( ) function returns the predicted operating time at the AtRate value of discharge. The default value for AtRate( ) is zero and forces AtRateTimeToEmpty( ) to return 65,535. Both the AtRate( ) and AtRateTimeToEmpty( ) commands must only be used in NORMAL mode. 4.1.1.3 AtRateTimeToEmpty( ): 0x04/0x05 This read-word function returns an unsigned integer value of the predicted remaining operating time if the battery is discharged at the AtRate( ) value in minutes with a range of 0 to 65,534. A value of 65,535 indicates AtRate( ) = 0. The fuel gauge updates AtRateTimeToEmpty( ) within 1 s after the system sets the AtRate( ) value. The fuel gauge automatically updates AtRateTimeToEmpty( ) based on the AtRate( ) value every 1 s. Both the AtRate( ) and AtRateTimeToEmpty( ) commands must only be used in NORMAL mode. 4.1.1.4 Temperature( ): 0x06/0x07 This read-/write-word function returns an unsigned integer value of the temperature in units of 0.1 K measured by the fuel gauge. If [WRTEMP] bit = 1, a write command sets the temperature to be used for gauging calculations while a read command returns to temperature previously written. If [WRTEMP] bit = 0 and [TEMPS] bit = 0, a read command will return the internal temperature sensor value. 4.1.1.5 Voltage( ): 0x08/0x09 This read-word function returns an unsigned integer value of the measured cell-pack voltage in mV with a range of 0 to 6000 mV. 4.1.1.6 Flags( ): 0x0a/0x0b This read-word function returns the contents of the fuel-gauge status register, depicting the current operating status. 14 GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Table 4-4. Flags Bit Definitions High byte Low byte bit7 OTC – bit6 OTD – bit5 – OCV_GD bit4 – WAIT_ID bit3 CHG_INH BAT_DET bit2 XCHG SOC1 bit1 FC SYSDOWN bit0 CHG DSG OTC = Overtemperature in charge condition is detected. True when set. SOC_INT will toggle once if set. OTD = Overtemperature in discharge condition is detected. True when set. SOC_INT will toggle once if set. CHG_INH = Charge inhibit: unable to begin charging (temperature outside the range [Charge Inhibit Temp Low, Charge Inhibit Temp High]). True when set. XCHG = Charge suspend alert (temperature outside the range [Suspend Temperature Low, Suspend Temperature High]). True when set. FC = Full-charged condition reached. Set when charge termination condition is met. (RMFCC=1; Set FC_Set % = -1% when RMFCC = 0). True when set CHG = (Fast) charging allowed. True when set. OCV_GD = Good OCV measurement taken. True when set. WAIT_ID = Waiting to identify inserted battery. True when set. BAT_DET = Battery detected. True when set. SOC1 = State-of-charge threshold 1 (SOC1 Set) reached. The flag is enabled when BL_INT bit in Operation Configuration B is set. True when set. SysDown = SystemDown bit indicating the system shut down. Refer to the Data Flash SysDown parameters for threshold settings. True when set. SOC_INT will toggle once if set. DSG = Discharging detected. True when set. 4.1.1.7 NominalAvailableCapacity( ): 0x0c/0x0d This read-only command pair returns the uncompensated (less than C/20 load) battery capacity remaining. Units are mAh. 4.1.1.8 FullAvailableCapacity( ): 0x0e/0x0f This read-only command pair returns the uncompensated (less than C/20 load) capacity of the battery when fully charged. Units are mAh. FullAvailableCapacity( ) is updated at regular intervals, as specified by the IT algorithm. 4.1.1.9 RemainingCapacity( ): 0x10/0x11 This read-only command pair returns the remaining battery capacity which is compensated for the present conditions of load, temperature and battery age. RemainingCapacity( ) is typically lower than the uncompensated NominalAvailableCapacity( ). Units are mAh. 4.1.1.10 FullChargeCapacity( ): 0x12/13 This read-only command pair returns the capacity of the battery when fully charged with compensation for the present conditions of temperature and battery age. FullChargeCapacity( ) is updated at regular intervals, as specified by the IT algorithm typically lower than the uncompensated FullAvailableCapacity( )and . Units are mAh. 4.1.1.11 AverageCurrent( ): 0x14/0x15 This read-only command pair returns a signed integer value that is the average current flow through the sense resistor. AverageCurrent( )is calculated by dividing the 1 second change in coulomb counter data by 1 second. Large current spikes of short duration will be averaged out in this measurement. Units are mA. 4.1.1.12 TimeToEmpty( ): 0x16/0x17 This read-only function returns an unsigned integer value of the predicted remaining battery life at the present rate of discharge, in minutes. A value of 65,535 indicates battery is not being discharged. GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 15 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 4.1.1.13 www.ti.com TimeToFull( ): 0x18/0x19 This read-only function returns an unsigned integer value of predicted remaining time until the battery reaches full charge, in minutes, based upon AverageCurrent( ). The computation accounts for the taper current time extension from the linear TTF computation based on a fixed AverageCurrent( ) rate of charge accumulation. A value of 65,535 indicates the battery is not being charged. 4.1.1.14 StandbyCurrent( ): 0x1a/0x1b This read-only function returns a signed integer value of the measured standby current through the sense resistor. The StandbyCurrent( ) is an adaptive measurement. Initially it reports the standby current programmed in Initial Standby, and after spending several seconds in standby, reports the measured standby current. The register value is updated every 1 second when the measured current is above the Deadband and is less than or equal to 2 × Initial Standby. The first and last values that meet this criteria are not averaged in, since they may not be stable values. To approximate a 1 minute time constant, each new StandbyCurrent( ) value is computed by taking approximate 93% weight of the last standby current and approximate 7% of the current measured average current. 4.1.1.15 StandbyTimeToEmpty( ): 0x1c/0x1d This read-only function returns an unsigned integer value of the predicted remaining battery life at the standby rate of discharge, in minutes. The computation uses Nominal Available Capacity (NAC), the uncompensated remaining capacity, for this computation. A value of 65,535 indicates battery is not being discharged. 4.1.1.16 MaxLoadCurrent( ): 0x1e/0x1f This read-only function returns a signed integer value, in units of mA, of the maximum load conditions. The MaxLoadCurrent( ) is an adaptive measurement which is initially reported as the maximum load current programmed in Initial Max Load Current. If the measured current is ever greater than Initial Max Load Current, then MaxLoadCurrent( ) updates to the new current. MaxLoadCurrent( ) is reduced to the average of the previous value and Initial Max Load Current whenever the battery is charged to full after a previous discharge to an SOC less than 50%. This prevents the reported value from maintaining an unusually high value. 4.1.1.17 MaxLoadTimeToEmpty( ): 0x20/0x21 This read-only function returns an unsigned integer value of the predicted remaining battery life at the maximum load current discharge rate, in minutes. A value of 65,535 indicates that the battery is not being discharged. 4.1.1.18 AvailableEnergy( ): 0x22/0x23 This read-only function returns an unsigned integer value of the predicted charge or energy remaining in the battery. The value is reported in units of mWh. 4.1.1.19 AveragePower( ): 0x24/0x25 This read-only function returns an signed integer value of the average power during battery charging and discharging. It is negative during discharge and positive during charge. A value of 0 indicates that the battery is not being discharged. The value is reported in units of mW. 4.1.1.20 TimeToEmptyAtConstantPower( ): 0x26/0x27 This read-only function returns an unsigned integer value of the predicted remaining operating time if the battery is discharged at the AveragePower( ) value in minutes. A value of 65,535 indicates AveragePower( ) = 0. The fuel gauge automatically updates TimeToEmptyatContantPower( ) based on the AveragePower( ) value every 1 s. 16 GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.1.1.21 StateofHealth( ): 0x28/0x29 0x28 SOH percentage: this read-only function returns an unsigned integer value, expressed as a percentage of the ratio of predicted FCC(25°C, SOH LoadI) over the DesignCapacity(). The FCC(25°C, SOH LoadI) is the calculated full charge capacity at 25°C and the SOH LoadI which is specified in the data flash. The range of the returned SOH percentage is 0x00 to 0x64, indicating 0 to 100% correspondingly. 0x29 SOH Status: this read-only function returns an unsigned integer value, indicating the status of the SOH percentage. The meanings of the returned value are: • 0x00: SOH not valid (initialization) • 0x01: Instant SOH value ready • 0x02: Initial SOH value ready – Calculation based on uncompensated Qmax – Updated at first grid point update after cell insertion • 0x03: SOH value ready – Utilize the updated Qmax update – Calculation based on compensated Qmax – Updated after complete charge and relax is complete • 0x04-0xFF: Reserved 4.1.1.22 CycleCount( ): 0x2a/0x2b This read-only function returns an unsigned integer value of the number of cycles that the active cell has experienced with a range of 0 to 65535. One cycle occurs when accumulated discharge ≥ CC Threshold. The gauge maintains a separate cycle counter for both cell profiles and will reset to zero if the insertion of a new pack has been detected. 4.1.1.23 StateOfCharge( ): 0x2c/0x2d This read-only function returns an unsigned integer value of the predicted remaining battery capacity expressed as a percentage of FullChargeCapacity( ), with a range of 0 to 100%. 4.1.1.24 NormalizedImpedanceCal( ): 0x2e/0x2f This read-only function returns an unsigned integer value of the calculated normalized impedance to 0°C at the current Depth of Discharge, with the unit of mΩ. 4.1.1.25 InstantaneousCurrent Reading( ) 0x30/0x31 This read-only function returns a signed integer value that is the instantaneous current flow through the sense resistor. The conversion time is 125ms. It is updated every 1 second. Units are mA. 4.1.1.26 DataLogIndex( ): 0x32/0x33 In Data Logging Mode, this read-only register returns an unsigned integer that increments for every new coulomb counter sample placed in the data FIFO and decrements for each sample read by the host from DataLogBuffer(). The index saturates at 30 counts to prevent rollover of the FIFO and subsequent data samples are discarded. Data logging is controlled by the ENABLE_DLOG and DISABLE_DLOG subcommands while status is provided by the CONTROL_STATUS[DLOGEN] bit. 4.1.1.27 DataLogBuffer( ): 0x34/0x35 In Data Logging Mode, this read-only register returns a 16-bit signed coulomb counter value in mA. Access to data is provided by a 30 sample FIFO with the number of samples available from DataLogIndex(). If the FIFO is empty, this value returned is 0x7FFF. GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 17 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.1.1.28 InternalTemperature( ): 0x36/0x37 This read-only function returns an unsigned integer value of the internal temperature sensor in units of 0.1 K measured by the fuel gauge. This function can be useful as an additional system-level temperature monitor if the main Temperature( ) function is configured for external or host reported temperature. 4.1.1.29 OperationConfiguration( ): 0x3A/0x3B This read-only function returns the contents of the data flash Operation Configuration register and is most useful for system level debug to quickly determine device configuration. 4.1.2 EXTENDED DATA COMMANDS Extended commands offer additional functionality beyond the standard set of commands. They are used in the same manner; however, unlike standard commands, extended commands are not limited to 2-byte words. The number of commands bytes for a given extended command ranges in size from single to multiple bytes, as specified in Table 4-5. Table 4-5. Extended Data Commands COMMAND CODE UNITS SEALED ACCESS (1) (2) UNSEALED ACCESS (1) (2) RSVD 0x34...0x3b N/A R R DesignCapacity( ) DCAP 0x3c / 0x3d mAh R R DataFlashClass( ) (2) DFCLS 0x3e N/A N/A R/W DataFlashBlock( ) (2) DFBLK 0x3f N/A R/W R/W NAME Reserved BlockData( ) DFD 0x40…0x5f N/A R R/W BlockDataCheckSum( ) DFDCKS 0x60 N/A R/W R/W BlockDataControl( ) DFDCNTL 0x61 N/A N/A R/W ApplicationStatus( ) APPSTAT 0x6a N/A R R RSVD 0x6b...0x7f N/A R R Reserved (1) (2) SEALED and UNSEALED states are entered via commands to Control() 0x00/0x01. In sealed mode, data flash CANNOT be accessed through commands 0x3e and 0x3f. 4.1.2.1 DesignCapacity( ): 0x3c/0x3d SEALED and UNSEALED Access: This command returns the value is stored in Design Capacity and is expressed in mAh. This is intended to be the theoretical or nominal capacity of a new pack, but has no bearing on the operation of the fuel gauge functionality. 4.1.2.2 DataFlashClass( ): 0x3e UNSEALED Access: This command sets the data flash class to be accessed. The class to be accessed must be entered in hexadecimal. SEALED Access: This command is not available in SEALED mode. 4.1.2.3 DataFlashBlock( ): 0x3f UNSEALED Access: This command sets the data flash block to be accessed. When 0x00 is written to BlockDataControl( ), DataFlashBlock( ) holds the block number of the data flash to be read or written. Example: writing a 0x00 to DataFlashBlock( ) specifies access to the first 32-byte block, a 0x01 specifies access to the second 32-byte block, and so on. SEALED Access: This command directs which data flash block is accessed by the BlockData( ) command. Writing a 0x01 or 0x02 instructs the BlockData( ) command to transfer the Manufacturer Info Block. All other DataFlashBlock( ) values are reserved. 18 GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.1.2.4 BlockData( ): 0x40…0x5f UNSEALED Access: This data block is the remainder of the 32 byte data block when accessing data flash. SEALED Access: This data block is the remainder of the 32 byte data block when accessing Manufacturer Block Info. 4.1.2.5 BlockDataChecksum( ): 0x60 UNSEALED Access: This byte contains the checksum on the 32 bytes of block data read or written to data flash. The least-significant byte of the sum of the data bytes written must be complemented ([255 – x], for x the least-significant byte) before being written to 0x60. SEALED Access: This byte contains the checksum for the 32 bytes of block data written to the Manufacturer Info Block. The least-significant byte of the sum of the data bytes written must be complemented ([255 – x], for x the least-significant byte) before being written to 0x60. 4.1.2.6 BlockDataControl( ): 0x61 UNSEALED Access: This command is used to control data flash access mode. Writing 0x00 to this command enables BlockData( ) to access general data flash. Writing a 0x01 to this command enables SEALED mode operation of DataFlashBlock( ). SEALED Access: This command is not available in SEALED mode. 4.1.2.7 ApplicationStatus( ): 0x6a This byte function allows the system to read the bq27520-G2 Application Status data flash location. See Table 6-1 for specific bit definitions. 4.1.2.8 4.2 4.2.1 Reserved — 0x6b–0x7f DATA FLASH INTERFACE ACCESSING THE DATA FLASH The bq27520-G2 data flash is a non-volatile memory that contains bq27520-G2 initialization, default, cell status, calibration, configuration, and user information. The data flash can be accessed in several different ways, depending on what mode the bq27520-G2 is operating in and what data is being accessed. Commonly accessed data flash memory locations, frequently read by a system, are conveniently accessed through specific instructions, already described in Section 4.1, DATA COMMANDS . These commands are available when the bq27520-G2 is either in UNSEALED or SEALED modes. Most data flash locations, however, are only accessible in UNSEALED mode by use of the bq27520-G2 evaluation software or by data flash block transfers. These locations should be optimized and/or fixed during the development and manufacture processes. They become part of a golden image file and can then be written to multiple battery packs. Once established, the values generally remain unchanged during end-equipment operation. To access data flash locations individually, the block containing the desired data flash location(s) must be transferred to the command register locations, where they can be read to the system or changed directly. This is accomplished by sending the set-up command BlockDataControl( ) (0x61) with data 0x00. Up to 32 bytes of data can be read directly from the BlockData( ) (0x40…0x5f), externally altered, then rewritten to the BlockData( ) command space. Alternatively, specific locations can be read, altered, and rewritten if their corresponding offsets are used to index into the BlockData( ) command space. Finally, the data residing in the command space is transferred to data flash, once the correct checksum for the whole block is written to BlockDataChecksum( ) (0x60). GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 19 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Occasionally, a data flash CLASS will be larger than the 32-byte block size. In this case, the DataFlashBlock( ) command is used to designate which 32-byte block the desired locations reside in. The correct command address is then given by 0x40 + offset modulo 32. For example, to access Terminate Voltage in the Gas Gauging class, DataFlashClass( ) is issued 80 (0x50) to set the class. Because the offset is 50, it must reside in the second 32-byte block. Hence, DataFlashBlock( ) is issued 0x01 to set the block offset, and the offset used to index into the BlockData( ) memory area is 0x40 + 50 modulo 32 = 0x40 + 18 = 0x40 + 0x12 = 0x52. Reading and writing subclass data are block operations up to 32 bytes in length. If during a write the data length exceeds the maximum block size, then the data is ignored. None of the data written to memory are bounded by the bq27520-G2 – the values are not rejected by the fuel gauge. Writing an incorrect value may result in hardware failure due to firmware program interpretation of the invalid data. The written data is persistent, so a power-on reset does resolve the fault. 20 GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 4.3 MANUFACTURER INFORMATION BLOCK The bq27520-G2 contains 32 bytes of user programmable data flash storage called the Manufacturer Info Block. The method for accessing these memory locations is slightly different, depending on whether the device is in UNSEALED or SEALED modes. When in UNSEALED mode and when and 0x00 has been written to BlockDataControl( ), accessing the manufacturer information blocks is identical to accessing general data flash locations. First, a DataFlashClass( ) command is used to set the subclass, then a DataFlashBlock( ) command sets the offset for the first data flash address within the subclass. The BlockData( ) command codes contain the referenced data flash data. When writing the data flash, a checksum is expected to be received by BlockDataChecksum( ). Only when the checksum is received and verified is the data actually written to data flash. When in SEALED mode or when 0x01 BlockDataControl( ) does not contain 0x00, data flash is no longer available in the manner used in UNSEALED mode. Rather than issuing subclass information, a designated Manufacturer Information Block is selected with the DataFlashBlock( ) command. Issuing a 0x01 or 0x02 with this command causes the corresponding information block to be transferred to the command space 0x40…0x5f for editing or reading by the system. Upon successful writing of checksum information to BlockDataChecksum( ), the modified block is returned to data flash. Note: The Manufacturer Info Block is read-only when in SEALED mode. 4.4 ACCESS MODES The bq27520-G2 provides three security modes (FULL ACCESS, UNSEALED, and SEALED) that control data flash access permissions, according to Table 4-6. Data Flash refers to those data flash locations, specified in Table 4-7, that are accessible to the user. Table 4-6. Data Flash Access Security Mode Data Flash Manufacture Info Block FULL ACCESS R/W R/W UNSEALED R/W R/W SEALED None R Although FULL ACCESS and UNSEALED modes appear identical, only FULL ACCESS allows the bq27520-G2 to write access-mode transition keys. 4.5 SEALING/UNSEALING DATA FLASH The bq27520-G2 implements a key-access scheme to transition between SEALED, UNSEALED, and FULL-ACCESS modes. Each transition requires that a unique set of two keys be sent to the bq27520-G2 via the Control( ) control command. The keys must be sent consecutively, with no other data being written to the Control( ) register in between. Note that to avoid conflict, the keys must be different from the codes presented in the CNTL DATA column of Table 4-2 subcommands. When in SEALED mode, the CONTROL_STATUS [SS] bit is set, but when the UNSEAL keys are correctly received by the bq27520-G2, the [SS] bit is cleared. When the full-access keys are correctly received, then the CONTROL_STATUS [FAS] bit is cleared. Both the sets of keys for each level are 2 bytes each in length and are stored in data flash. The UNSEAL key (stored at Unseal Key 0 and Unseal Key 1) and the FULL-ACCESS key (stored at Full-Access Key 0 and Full-Access Key 1) can only be updated when in FULL-ACCESS mode. The order of the keys is Key 1 followed by Key 0. The order of the bytes entered through the Control( ) command is the reverse of what is read from the part. For example, if the Key 1 and Key 0 of the Unseal Keys returns 0x1234 and 0x5678, then the Control( ) should supply 0x3412 and 0x7856 to unseal the part. GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 21 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 4.6 www.ti.com DATA FLASH SUMMARY Table 4-7 summarizes the data flash locations available to the user, including their default, minimum, and maximum values. Table 4-7. Data Flash Summary Class Subclass ID Subclass Offset Data Type Min Value Max Value Default Value Units Configuration 2 Safety 0 Configuration 2 Safety 2 OT Chg I2 0 1200 550 0.1°C OT Chg Time U1 0 60 2 Configuration 2 Safety s 3 OT Chg Recovery I2 0 1200 500 0.1°C Configuration 2 Configuration 2 Safety 5 OT Dsg I2 0 1200 600 0.1°C Safety 7 OT Dsg Time U1 0 60 2 Configuration s 2 Safety 8 OT Dsg Recovery I2 0 1200 550 0.1°C Configuration 32 Charge Inhibit Temp Low 0 Charge Inhibit Temp Low I2 –400 1200 0 0.1°C Configuration 32 Charge Inhibit Temp High 2 Charge Inhibit Temp High I2 –400 1200 450 0.1°C Configuration 32 Temp Hysteresis 4 Temp Hys I2 0 100 50 0.1°C Configuration 34 Charge 2 Charging Voltage I2 0 4600 4200 mV Configuration 34 Charge 4 Delta Temp I2 0 500 50 0.1°C Configuration 34 Charge 6 Suspend Low Temp I2 –400 1200 -50 0.1°C Configuration 34 Charge 8 Suspend High Temp I2 –400 1200 550 0.1°C Configuration 36 Charge Termination 2 Taper Current I2 0 1000 100 mA Configuration 36 Charge Termination 4 Min Taper Capacity I2 0 1000 25 0.01mAh Configuration 36 Charge Termination 6 Taper Voltage I2 0 1000 100 mV Configuration 36 Charge Termination 8 Current Taper Window U1 0 60 40 s Configuration 36 Charge Termination 11 FC Set % I1 –1 100 100 % Configuration 36 Charge Termination 12 FC Clear % I1 –1 100 98 % Configuration 36 Charge Termination 13 DOD at EOC I2 0 1000 100 0.1°C Configuration 48 Data 4 Initial Standby Current I1 –128 0 –10 mA Configuration 48 Data 5 Initial Max Load Current I2 –32,767 0 –500 mA Configuration 48 Data 7 CC Threshold I2 100 32,767 900 mAh Configuration 48 Data 10 Design Capacity I2 0 65,535 1000 mAh Configuration 48 Data 12 SOH Load I2 –32,767 0 –400 mA Configuration 48 Data 14 Default Temp I2 0 1000 250 (1) 0.1°C Configuration 48 Data 16 Device name S8 x x bq27520 – Configuration 48 Data 24 Data Flash Version H2 0x00 0xFF 0x00 – Configuration 49 Discharge 0 SOC1 Set Threshold U1 0 255 150 mAh Configuration 49 Discharge 1 SOC1 Clear Threshold U1 0 255 175 mAh Configuration 49 Discharge 5 SysDown Set Volt Threshold I2 0 4200 3150 mV Configuration 49 Discharge 7 SysDown Set Volt Time U1 0 60 2 s Configuration 49 Discharge 8 SysDown Clear Volt Threshold I2 0 4200 3400 mV Configuration 49 Discharge 15 Final Voltage U2 0 4200 3000 mV System Data 57 Manufacturer Info 0–31 Block [0 – 31] H1 0x00 0xff 0x00 – Configuration 64 Registers 0 Operation Configuration H2 0x0000 0xffff 0x0973 – (1) 22 Name Display as the value EVSW displayed. Data Flash value is different. GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Table 4-7. Data Flash Summary (continued) Class Subclass ID Subclass Offset Data Type Min Value Max Value Default Value Configuration 64 Registers 7 Configuration 64 Registers 8 SOC Delta U1 0 25 1 % I2C Timeout U1 0 7 4 num Configuration 64 Registers Configuration 64 Registers 9 DFWrIndWaitTime U2 0 65535 0 5μs 11 OpConfigB H1 0x00 0xff 0x4B Configuration 64 Registers – 12 OpConfigC H1 0x00 0xff 0x2C Configuration 64 – Registers 13 Clock Control Register H1 0x00 0xff 0x09 – Configuration Configuration 68 Power 0 Flash Update OK Voltage I2 0 4200 2800 mV 68 Power 7 Sleep Current I2 0 100 10 mA Configuration 68 Power 16 Hibernate Current U2 0 700 8 mA Configuration 68 Power 18 Hibernate Voltage U2 2400 3000 2550 mV Gas Gauging 80 IT Cfg 21 Max Res Factor U1 0 255 20 num Gas Gauging 80 IT Cfg 22 Min Res Factor U1 0 255 5 num Gas Gauging 80 IT Cfg 0 Load Select U1 0 255 1 – Gas Gauging 80 IT Cfg 1 Load Mode U1 0 255 0 – Gas Gauging 80 IT Cfg 24 Ra Filter U2 0 1000 500 num Gas Gauging 80 IT Cfg 40 Min % Passed Charge for Qmax U1 1 100 37 % Gas Gauging 80 IT Cfg 44 Qmax Filter U1 0 255 96 num Gas Gauging 80 IT Cfg 45 Terminate Voltage I2 –32,768 32,767 3400 mV Gas Gauging 80 IT Cfg 47 Term V Delta I2 0 4200 200 mV Gas Gauging 80 IT Cfg 50 ResRelax Time U2 0 65534 500 s Gas Gauging 80 IT Cfg 54 User Rate-mA I2 –2000 –100 0 mA Gas Gauging 80 IT Cfg 56 User Rate-mW I2 –7200 –350 0 mW Gas Gauging 80 IT Cfg 58 Reserve Cap-mAh I2 0 9000 0 mAh Gas Gauging 80 IT Cfg 60 Reserve Cap-mWh I2 0 14,000 0 mWh Gas Gauging 80 IT Cfg 65 Min Delta Voltage I2 –32,000 32,000 0 mV Gas Gauging 80 IT Cfg 67 Max Sim Rate U1 0 255 2 C/rate Gas Gauging 80 IT Cfg 68 Min Sim Rate U1 0 255 20 C/rate Gas Gauging 80 IT Cfg 69 Ra MAx Delta U2 0 65,535 44 mΩ Gas Gauging 80 IT Cfg 71 Qmax MAx Delta% U1 0 255 5 % Gas Gauging 80 IT Cfg 72 DeltaV Max dV U2 0 65,535 10 mV Gas Gauging 80 IT Cfg 74 Max Res Scale U2 0 32767 5000 num Gas Gauging 80 IT Cfg 76 Min Res Scale U2 0 32767 200 num Gas Gauging 80 IT Cfg 78 Fast Scale Start SOC U1 0 100 10 % Gas Gauging 81 Current Thresholds 0 Dsg Current Threshold I2 0 2000 60 mA Gas Gauging 81 Current Thresholds 2 Chg Current Threshold I2 0 2000 75 mA Gas Gauging 81 Current Thresholds 4 Quit Current I2 0 1000 40 mA Gas Gauging 81 Current Thresholds 6 Dsg Relax Time U2 0 8191 60 s Gas Gauging 81 Current Thresholds 8 Chg Relax Time U1 0 255 60 s Gas Gauging 81 Current Thresholds 9 Quit Relax Time U1 0 63 1 s Gas Gauging 81 Current Thresholds 10 Transient Factor Charge U1 0 255 255 num Gas Gauging 81 Current Thresholds 11 Transient Factor Discharge U1 0 255 255 num Gas Gauging 81 Current Thresholds 12 Max IR Correct U2 0 1,000 400 mV Gas Gauging 82 State 0 IT Enable H1 0x00 0x03 0x00 – Name GENERAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 Units 23 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Table 4-7. Data Flash Summary (continued) Class Subclass ID Subclass Offset Data Type Min Value Gas Gauging 82 State 1 Gas Gauging 82 State 2 Application Status H1 0x00 0xff 0x00 – Qmax 0 I2 0 32,767 1000 mAh Gas Gauging 82 State Gas Gauging 82 State 4 Cycle Count 0 U2 0 65,535 0 – 6 Update Status 0 H1 0x00 0x03 0x00 Gas Gauging 82 State – 7 Qmax 1 I2 0 32767 1000 mAh Gas Gauging 82 Gas Gauging 82 State 9 Cycle Count 1 U2 0 65,535 0 Count State 11 Update Status 1 H1 0x00 0x03 0x00 Gas Gauging – 82 State 12 Cell0 Chg DOD at EoC I2 0 16384 0 – Gas Gauging 82 State 14 Cell1 Chg DOD at EoC I2 0 16384 0 – Gas Gauging 82 State 16 Avg I Last Run I2 –32,768 32,767 –299 mA Gas Gauging 82 State 18 Avg P Last Run I2 –32,768 32,767 –1131 mAh Gas Gauging 82 State 20 Delta Voltage I2 –32,768 32,768 2 mV Gas Gauging 82 State 24 T Rise U2 0 65535 2 num Gas Gauging 82 State 26 T Time Constant U2 0 65535 1000 num Name (2) Max Value Default Value Units (3) mohm Calibration 104 Data 0 CC Gain F4 0.1 47 10 Calibration 104 Data 4 CC Delta F4 (2) 4.7 188 10 (3) mohm Calibration 104 Data 8 CC Offset I2 –2.4 2.4 –0.58 (3) mV Calibration 104 Data 10 ADC Offset I2 –500 500 0 mV Calibration 104 Data 12 Board Offset I1 –128 127 0 mV Calibration 104 Data 13 Int Temp Offset I1 –128 127 0 0.1°C Calibration 104 Data 14 Ext Temp Offset I1 –128 127 0 0.1°C Calibration 104 Data 15 Pack V Offset I1 –128 127 0 mV Calibration 107 Current 1 Deadband U1 0 255 5 mA Security 112 Codes 0 Unseal Key 0 H2 0x0000 0xffff 0x3672 – Security 112 Codes 2 Unseal Key 1 H2 0x0000 0xffff 0x0414 – Security 112 Codes 4 Unsealed to Full 0 H2 0x0000 0xffff 0xffff – Security 112 Codes 6 Unsealed to Full 1 H2 0x0000 0xffff 0xffff – Security 112 Codes 24 FactRestorkey 0 H2 0x0000 0xffff 0x0DEF – Security 112 Codes 26 FactRestorkey 1 H2 0x0000 0xffff 0x0FAC – (2) (3) Not IEEE floating point. Display as the value EVSW displayed. Data Flash value is different. 5 FUNCTIONAL DESCRIPTION 5.1 FUEL GAUGING The bq27520-G2 measures the cell voltage, temperature, and current to determine battery SOC. The bq27520-G2 monitors charge and discharge activity by sensing the voltage across a small-value resistor (5 mΩ to 20 mΩ typ.) between the SRP and SRN pins and in series with the cell. By integrating charge passing through the battery, the battery’s SOC is adjusted during battery charge or discharge. The total battery capacity is found by comparing states of charge before and after applying the load with the amount of charge passed. When an application load is applied, the impedance of the cell is measured by comparing the OCV obtained from a predefined function for present SOC with the measured voltage under load. Measurements of OCV and charge integration determine chemical state of charge and chemical capacity (Qmax). The initial Qmax values are taken from a cell manufacturers' data sheet multiplied by the number of parallel cells. It is also used for the value in Design Capacity. The bq27520-G2 acquires and updates the battery-impedance profile during normal battery usage. It uses this 24 FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com profile, along with SOC and the Qmax value, to determine FullChargeCapacity( ) and StateOfCharge( ), specifically for the present load and temperature. FullChargeCapacity( ) is reported as capacity available from a fully charged battery under the present load and temperature until Voltage( ) reaches the Terminate Voltage. NominalAvailableCapacity( ) and FullAvailableCapacity( ) are the uncompensated (no or light load) versions of RemainingCapacity( ) and FullChargeCapacity( ) respectively. The bq27520-G2 has two flags accessed by the Flags( ) function that warns when the battery’s SOC has fallen to critical levels. When RemainingCapacity( ) falls below the first capacity threshold, specified in SOC1 Set Threshold, the [SOC1] (State of Charge Initial) flag is set. The flag is cleared once RemainingCapacity( ) rises above SOC1 Set Threshold. The bq27520-G2’s BAT_LOW pin automatically reflects the status of the [SOC1] flag. This flag is enabled when BL_INT bit in Operation Configuration B is set. All units are in mAh. When Voltage( ) falls below the system shut down threshold voltage, SysDown Set Volt Threshold, the [SYSDOWN] flag is set, serving as a final warning to shut down the system. The SOC_INT also signals. When Voltage( ) rises above SysDown Clear Voltage and the [SYSDOWN] flag has already been set, the [SYSDOWN] flag is cleared. The SOC_INT also signals such change. All units are in mV. When the voltage is discharged to Final Voltage, the SOC will be set as 0. 5.2 IMPEDANCE TRACK™ VARIABLES The bq27520-G2 has several data flash variables that permit the user to customize the Impedance Track™ algorithm for optimized performance. These variables are dependent upon the power characteristics of the application as well as the cell itself. 5.2.1 Load Mode Load Mode is used to select either the constant-current or constant-power model for the Impedance Track™ algorithm as used in Load Select (see Load Select). When Load Mode is 0, the Constant Current Model is used (default). When 1, the Constant Power Model is used. The [LDMD] bit of CONTROL_STATUS reflects the status of Load Mode. 5.2.2 Load Select Load Select defines the type of power or current model to be used to compute load-compensated capacity in the Impedance Track™ algorithm. If Load Mode = 0 (Constant-Current) then the options presented in Table 5-1 are available. Table 5-1. Constant-Current Model Used When Load Mode = 0 LoadSelect Value 0 1(default) Current Model Used Average discharge current from previous cycle: There is an internal register that records the average discharge current through each entire discharge cycle. The previous average is stored in this register. Present average discharge current: This is the average discharge current from the beginning of this discharge cycle until present time. 2 Average current: based on AverageCurrent( ) 3 Current: based off of a low-pass-filtered version of AverageCurrent( ) (τ =14 s) 4 Design capacity / 5: C Rate based off of Design Capacity /5 or a C/5 rate in mA. 5 AtRate (mA): Use whatever current is in AtRate( ) 6 User_Rate-mA: Use the value in User_Rate-mA. This mode provides a completely user-configurable method. If Load Mode = 1 (Constant Power) then the following options shown in Table 5-2 are available FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 25 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Table 5-2. Constant-Power Model Used When Load Mode = 1 LoadSelect Value Power Model Used 0 Average discharge power from previous cycle: There is an internal register that records the average discharge power through each entire discharge cycle. The previous average is stored in this register. 1(default) 5.2.3 Present average discharge power: This is the average discharge power from the beginning of this discharge cycle until present time. 2 Average current × voltage: based off the AverageCurrent( ) and Voltage( ). 3 Current × voltage: based off of a low-pass-filtered version of AverageCurrent( ) (τ=14 s) and Voltage( ) 4 Design energy / 5: C Rate based off of Design Energy /5 or a C/5 rate in mA. 5 AtRate (10 mW): Use whatever value is in AtRate( ). 6 User_Rate-10mW: Use the value in User_Rate-10mW. This mode provides a completely user-configurable method. Reserve Cap-mAh Reserve Cap-mAh determines how much actual remaining capacity exists after reaching 0 RemainingCapacity( ), before Terminate Voltage is reached. A no-load rate of compensation is applied to this reserve. 5.2.4 Reserve Cap-mWh Reserve Cap-mWh determines how much actual remaining capacity exists after reaching 0 AvailableEnergy( ), before Terminate Voltage is reached. A no-load rate of compensation is applied to this reserve capacity. 5.2.5 Dsg Current Threshold This register is used as a threshold by many functions in the bq27520-G2 to determine if actual discharge current is flowing into or out of the cell. The default for this register is in Table 4-7, which should be sufficient for most applications. This threshold should be set low enough to be below any normal application load current but high enough to prevent noise or drift from affecting the measurement. 5.2.6 Chg Current Threshold This register is used as a threshold by many functions in the bq27520-G2 to determine if actual charge current is flowing into or out of the cell. The default for this register is in Table 4-7, which should be sufficient for most applications. This threshold should be set low enough to be below any normal charge current but high enough to prevent noise or drift from affecting the measurement. 5.2.7 Quit Current, DSG Relax Time, CHG Relax Time, and Quit Relax Time The Quit Current is used as part of the Impedance Track™ algorithm to determine when the bq27520-G2 enters relaxation mode from a current-flowing mode in either the charge direction or the discharge direction. The value of Quit Current is set to a default value in Table 4-7 and should be above the standby current of the system. Either of the following criteria must be met to enter relaxation mode: • | AverageCurrent( ) | < | Quit Current | for Dsg Relax Time • | AverageCurrent( ) | < | Quit Current | for Chg Relax Time After about 5 minutes in relaxation mode, the bq27520-G2 attempts to take accurate OCV readings. An additional requirement of dV/dt < 4 μV/s is required for the bq27520-G2 to perform Qmax updates. These updates are used in the Impedance Track™ algorithms. It is critical that the battery voltage be relaxed during OCV readings to and that the current is not be higher than C/20 when attempting to go into relaxation mode. Quit Relax Time specifies the minimum time required for AverageCurrent( ) to remain above the QuitCurrent threshold before exiting relaxation mode. 26 FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 5.2.8 Qmax 0 and Qmax 1 Generically called Qmax, these dynamic variables contain the respective maximum chemical capacity of the active cell profiles, and are determined by comparing states of charge before and after applying the load with the amount of charge passed. They also correspond to capacity at a low rate of discharge, such as the C/20 rate. For high accuracy, this value is periodically updated by the bq27520-G2 during operation. Based on the battery cell capacity information, the initial value of chemical capacity should be entered in the Qmax n field for each default cell profile. The Impedance Track™ algorithm updates these values and maintains them the associated actual cell profiles. 5.2.9 Update Status 0 and Update Status 1 Bit 0 (0x01) of the Update Status n registers is updated as needed by the bq27520-G2 to indicate that new Qmax parameters have been learned. The Update Status n registers are modified automatically by the bq27520-G2 and TI's evaluation software during the process of creating a golden Data Flash file. The remaining bits are reserved. 5.2.10 Avg I Last Run The bq27520-G2 logs the current averaged from the beginning to the end of each discharge cycle. It stores this average current from the previous discharge cycle in this register. This register should not be modified. It is only updated by the bq27520-G2 when required. 5.2.11 Avg P Last Run The bq27520-G2 logs the power averaged from the beginning to the end of each discharge cycle. It stores this average power from the previous discharge cycle in this register. To get a correct average power reading the bq27520-G2 continuously multiplies instantaneous current times Voltage( ) to get power. It then logs this data to derive the average power. This register should not be modified. It is only updated by the bq27520-G2 when required. 5.2.12 Delta Voltage The bq27520-G2 stores the maximum difference of Voltage( ) during short load spikes and normal load, so the Impedance Track™ algorithm can calculate remaining capacity for pulsed loads. It is not recommended to change this value. 5.2.13 Default Ra and Ra Tables These tables contain encoded data and, with the exception of the Default Ra Tables, are automatically updated during device operation. No user changes should be made except for reading/writing the values from a pre-learned pack (part of the process for creating golden image files). 5.3 5.3.1 DETAILED PIN DESCRIPTION The Operation Configuration Register Some bq27520-G2 pins are configured via the Operation Configuration data flash register, as indicated in Table 5-3. This register is programmed/read via the methods described in Section 4.2.1, Accessing the Data Flash. The register is located at subclass = 64, offset = 0. FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 27 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Table 5-3. Operation Configuration Bit Definition High byte Low byte bit7 RESCAP INT_FOCV bit6 BATG_OVR IDSELEN bit5 INT_BREM SLEEP bit4 PFC_CFG1 RMFCC bit3 PFC_CFG0 SOCI_POL bit2 IWAKE BATG_POL bit1 RSNS1 BATL_POL bit0 RSNS0 TEMPS RESCAP = No-load rate of compensation is applied to the reserve capacity calculation. True when set. Default is 0. BATG_OVR = BAT_GD override bit. If the gauge enters Hibernate only due to the cell voltage, the BAT_GD pin will not negate. True when set. Default is 0. INT_BERM = Battery removal interrupt bit. The SOC_INT pulses 1ms when the battery removal interrupt is enabled. True when set. The default is 0. PFC_CFG1/PFC_CFG0 = Pin function code (PFC) mode selection: PFC 0, 1, or 2 selected by 0/0, 0/1, or 1/0, respectively. Default is PFC 1 (0/1). IWAKE/RSNS1/RSNS0 = These bits configure the current wake function (see Table 5-7). Default is 0/0/1. INT_FOCV = Indication of the measurement of the OCV during the initialization. The SOC_INT will pulse during the first measurement if this bit is set. True when set. Default is 0. IDSELEN = Enables cell profile selection feature. True when set. Default is 1. SLEEP = The fuel gauge can enter sleep, if operating conditions allow. True when set. Default is 1. RMFCC = RM is updated with the value from FCC, on valid charge termination. True when set. Default is 1. SOCI_POL = SOC interrupt polarity is active-low. True when cleared. Default is 0. BATG_POL = BAT_GD pin is active-low. True when cleared. Default is 0. BATL_POL = BAT_LOW pin is active-high. True when set. Default is 1. TEMPS = Selects external thermistor for Temperature( ) measurements. True when set. Default is 1. Some bq27520-G2 pins are configured via the Operation Configuration B data flash register, as indicated in Table 5-4. This register is programmed/read via the methods described in Section 4.2.1: Accessing the Data Flash. The register is located at subclass = 64, offset = 9. Table 5-4. Operation Configuration B Bit Definition bit7 WRTEMP bit6 BIE bit5 BL_INT bit4 GNDSEL bit3 FCE bit2 DFWrIndBL bit1 RFACTSTEP bit0 INDFACRES WRTEMP = Enables the temperature write. The temperature could be written by the host. True when set. Default is 0. BIE = Battery insertion detection enable. When the battery insertion detection is disabled, the gauge relies on the host command to set the BAT_DET bit. True when set. Default is 1. BL_INT = Battery low interrupt enable. True when set. Default is 0. GNDSEL = The ADC ground select control. The Vss (Pin D1) is selected as ground reference when the bit is clear. Pin A1 is selected when the bit is set. Default is 0. FCE = Fast Convergence Enable. Configures algorithm to use fast convergence method. Default is 1 and is the recommended setting for all applications. DFWrIndBL = DataFlash Write Indication. SOC_INT is used for indication if the bit is clear. BAT_LOW is used for indication if the bit is set. Default is 0. RFACTSTEP = Enables Ra Step up/down to Min/Max Res Factor before disabling Ra updates. Default is 1. INDFACRES = Enables SOC_INT pin to assert during FACTORY_RESTORE subcommand execution . Default is 1. Table 5-5. Operation Configuration C Bit Definition bit7 BATGSPUEN bit6 BATGWPUEN bit5 BATLSPUEN bit4 BATLWPUEN bit3 RSVD bit2 SlpWkChg bit1 DeltaVOpt1 bit0 DeltaVOpt0 BATGSPUEN = BAT_GD pin strong pull-up enable. Default is 0. BATGWPUEN = BAT_GD pin weak pull-up enable. Default is 0. BATLSPUEN = BAT_LOW pin strong pull-up enable. Default is 1. BATLWPUEN = BAT_LOW pin weak pull-up enable. Default is 0. SlpWkChg = Enables compensation for the passed charge missed when waking from SLEEP mode. Default is 1. DeltaVOpt[1:0] = Configures options for determination of Delta Voltage which is defined as the maximum difference in Voltage( ) during normal load and short load spikes. Delta Voltage is a used as a compensation factor for calculating for RemainingCapacity( ) under pulsed loads. Default is 0/0. 0/0 = Standard DeltaV. Average variance from steady state voltage used to determine end of discharge voltage. (Default) 0/1 = No Averaging. The last instantaneous change in Voltage( ) from steady state is used to determine the end of discharge voltage. 1/0 = Use the value in Min Delta Voltage. 1/1 = Not used. 28 FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 5.3.2 Pin Function Code Descriptions The bq27520-G2 has three possible pin-function variations that can be selected in accordance with the circuit architecture of the end application. Each variation has been assigned a pin function code, or PFC. When the PFC is set to 0, only the bq27520-G2 measures battery temperature under discharge and relaxation conditions. The charger does not receive any information from the bq27520-G2 about the temperature readings, and therefore operates open-loop with respect to battery temperature. A PFC of 1 is like a PFC of 0, except temperature is also monitored during battery charging. If charging temperature falls outside of the preset range defined in data flash, a charger can be disabled via the BAT_GD pin until cell temperature recovers. See Section 5.6.2, Charge Inhibit and Suspend, for additional details. Finally when the PFC is set to 2, the battery thermistor can be shared between the fuel gauge and the charger. The charger has full usage of the thermistor during battery charging, while the fuel gauge uses the thermistor exclusively during discharge and battery relaxation. When PFC = 0 or 2, the bq27520-G2 must be queried by the system in order to determine the battery temperature. At that time, the bq27520-G2 samples the temperature. This saves battery energy when operating from battery, as periodic temperature updates are avoided during charging mode. Note: Due to thermistor sharing limitations, temperature data is not available during battery charging with PFC = 2. The PFC is specified in Operation Configuration [PFC_CFG1, PFC_CFG0]. The default is PFC = 1. 5.3.3 BAT_LOW Pin The BAT_LOW pin provides a system processor with an electrical indicator of battery status. The signaling on the BAT_LOW pin follows the status of the [SOC1] bit in the Flags( ) register. Note that the polarity of the BAT_LOW pin can be inverted via the [BATL_POL] bit of Operation Configuration. 5.3.4 Power Path Control With the BAT_GD Pin The bq27520-G2 must operate in conjunction with other electronics in a system appliance, such as chargers or other ICs and application circuits that draw appreciable power. After a battery is inserted into the system, there should be no charging current or a discharging current higher than C/20, so that an accurate OCV can be read. The OCV is used for helping determine which battery profile to use, as it constitutes part of the battery impedance measurement When a battery is inserted into a system, the Impedance Track™ algorithm requires that no charging of the battery takes place and that any discharge is limited to less than C/20—these conditions are sufficient for the fuel gauge to take an accurate OCV reading. To disable these functions, the BAT_GD pin is merely negated from the default setting. Once an OCV reading has be made, the BAT_GD pin is asserted, thereby enabling battery charging and regular discharge of the battery. The Operation Configuration [BATG_POL] bit can be used to set the polarity of the battery good signal, should the default configuration need to be changed. FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 29 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com POR Exit From HIBERNATE Battery Removed BAT INSERT CHECK Exit From HIBERNATE Communication Activity AND Comm address is for bq27520 Check for battery insertion from HALT state. No gauging bq27520 clears Control Status [HIBERNATE ] = 0 Recommend Host also set Control Status [HIBERNATE] = 0 Flags [BAT _DET] = 0 Entry to NORMAL Exit From NORMAL Flags [BAT _DET] = 1 Flags [BAT _DET] = 0 Exit From SLEEP NORMAL Flags [BAT_DET] = 0 Fuel gauging and data updated every 1s HIBERNATE Wakeup From HIBERNATE Communication Activity AND Comm address is NOT for bq27520 Disable all bq27520 subcircuits except GPIO. Negate BAT_GD Exit From SLEEP | AverageCurrent( ) | > Sleep Current OR Current is Detected above IWAKE Entry to SLEEP+ Operation Configuration[SLEEP] = 1 AND Control Status[SNOOZE] = 1 AND | AverageCurrent( ) | ≤ Sleep Current Entry to SLEEP Operation Configuration[SLEEP] = 1 AND | AverageCurrent( ) | ≤ Sleep Current AND Control Status[SNOOZE] = 0 Exit From SLEEP+ Any communication to the gauge OR | AverageCurrent( ) | > Sleep Current OR Current is Detected above I WAKE SLEEP+ Fuel gauging and data updated every 20 seconds Both LFO and HFO are ON Exit From WAIT_HIBERNATE Cell relaxed AND | AverageCurrent() | < Hibernate Current WAIT_HIBERNATE Entry to SLEEP+ Control Status[SNOOZE] = 0 SLEEP OR V CELL Cell relaxed AND < Hibernate Voltage Entry to SLEEP+ Control Status[SNOOZE] = 1 Fuel gauging and data updated every 20 seconds BAT_GD unchanged Exit From WAIT _HIBERNATE Host must set Control Status [HIBERNATE ] = 0 AND VCELL > Hibernate Voltage System Shutdown Fuel gauging and data updated every 20 seconds (LFO ON and HFO OFF) Exit From SLEEP (Host has set Control Status [HIBERNATE] = 1 OR VCELL < Hibernate Voltage System Sleep Figure 5-1. Power Mode Diagram Figure 5-1 details how the BAT_GD pin functions in the context of battery insertion and removal, as well as NORMAL vs. SLEEP modes. In PFC 1, the BAT_GD pin is also used to disable battery charging when the bq27520-G2 reads battery temperatures outside the range defined by [Charge Inhibit Temp Low, Charge Inhibit Temp High]. The BAT_GD line is asserted once temperature falls within the range [Charge Inhibit Temp Low + Temp Hys, Charge Inhibit Temp High – Temp Hys]. 5.3.5 Battery Detection Using the BI/TOUT Pin During power-up or hibernate activities, or any other activity where the bq27520-G2 needs to determine whether a battery is connected or not, the fuel gauge applies a test for battery presence. First, the BI/TOUT pin is put into high-Z status. The weak 1.8MΩ pull-up resistor will keep the pin high while no battery is present. When a battery is inserted (or is already inserted) into the system device, the BI/TOUT pin will be pulled low. This state is detected by the fuel gauge, which polls this pin every second when the gauge has power. A battery-disconnected status is assumed when the bq27520-G2 reads a thermistor voltage that is near 2.5V. 30 FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 5.3.6 SOC_INT pin The SOC_INT pin generates a pulse of different pulse widths under various conditions as indicated by the table below. After initialization only one SOC_INT pulse will be generated within any given one second time slot and therefore, may indicate multiple event conditions. Table 5-6. SOC_INT Pulse Condition and Width Enable Condition Pulse Width Comment During charge, when the SOC is greater than (>) the points, 100% - n × SOC_Delta and 100%; During discharge, when the SOC reaches (≤) the points 100% - n × SOC_Delta and 0%; where n is an integer starting from 0 to the number generating SOC no less than 0% SOC_Delta Point SOC_Delta ≠ 0 1 ms SOC1 Set Always 1 ms SOC1 Clear Always 1 ms SysDown Set Always 1 ms SysDown Clear Always 1 ms State Change SOC_Delta ≠ 0 1 ms When there is a state change including charging, discharging and relaxation. This function is disabled when SOC_Delta is set to 0. INT_BREM bit is set in OpConfig AND BIE bit is set 1 ms This function is disabled when BIE is cleared. After Initialization About 165ms. Same as the OCV command execution time period SOC_INT pulses for the OCV command after the initialization. OCV Command OCV Command INT_FOCV bit is set in OpConfig About 165ms. Same as the OCV command execution time period This command is to generate the SOC_INT pulse during the initialization. Data Flash Write After Initialization AND DFWrIndWaitTime ≠ 0 Programmable pulse width flash (see comment) SOC_INT is used to indicate the data flash update. The gauge will wait DFWrIndWaitTime times 5μs after the SOC_INT signal to start the data flash update. This function is disabled if DFWrIndWaitTime is set to 0. OTC or OTD Flags Always 1 ms Upon first assertion of Flags[OTC] or Flags[OTD] over temperature conditions. Factory Restore INDFACRES bit is set in OpConfig B About 450 ms The Factory Restore command instructs the fuel gauge to reset learned resistance tables and Qmax values to the default values. Battery Removal When RSOC reached the SOC1 Set or Clear threshold set in the Data Flash and BL_INT bit in Operation Configuration B is set. When the Battery Voltage reached the SysDown Set or Clear threshold set in the Data Flash FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 31 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 5.4 www.ti.com TEMPERATURE MEASUREMENT The bq27520-G2 measures battery temperature via its TS input, in order to supply battery temperature status information to the fuel gauging algorithm and charger-control sections of the gauge. Alternatively, it can also measure internal temperature via its on-chip temperature sensor, but only if the [TEMPS] bit of the Operation Configuration register is cleared. The [GNDSEL] bit of Operation Configuration B register selects the ground reference of the ADC converter for temperature measurement. A third option is enabled if the [WRTEMP] bit of Operation Configuration B is set. This allows a host processor to write the temperature measurement directly to the bq27520-G2 instead of the gauge making its own temperature measurements. Regardless of which sensor is used for measurement, a system processor can request the current battery temperature by calling the Temperature( ) function (see Section 4.1.1, Standard Data Commands, for specific information). The thermistor circuit requires the use of an external NTC 103AT-type thermistor. Additional circuit information for connecting this thermistor to the bq27520-G2 is shown in Section 8, Reference Schematic. 5.5 5.5.1 OVERTEMPERATURE INDICATION Overtemperature: Charge If during charging, Temperature( ) reaches the threshold of OT Chg for a period of OT Chg Time and AverageCurrent( ) > Chg Current Threshold, then the [OTC] bit of Flags( ) is set. When Temperature( ) falls to OT Chg Recovery, the [OTC] of Flags( ) is reset. If OT Chg Time = 0, then the feature is completely disabled. 5.5.2 Overtemperature: Discharge If during discharging, Temperature( ) reaches the threshold of OT Dsg for a period of OT Dsg Time, and AverageCurrent( ) ≤ –Dsg Current Threshold, then the [OTD] bit of Flags( ) is set. When Temperature( ) falls to OT Dsg Recovery, the [OTD] bit of Flags( ) is reset. If OT Dsg Time = 0, then feature is completely disabled. 5.6 5.6.1 CHARGING AND CHARGE-TERMINATION INDICATION Detecting Charge Termination For proper bq27520-G2 operation, the cell charging voltage must be specified by the user. The default value for this variable is Charging Voltage Table 4-7. The bq27520-G2 detects charge termination when (1) during 2 consecutive periods of Current Taper Window, the AverageCurrent( ) is < Taper Current, (2) during the same periods, the accumulated change in capacity > Min Taper Capacity /Current Taper Window, and (3) Voltage( ) > Charging Voltage – Taper Voltage. When this occurs, the [CHG] bit of Flags( ) is cleared. Also, if the [RMFCC] bit of Operation Configuration is set, then RemainingCapacity( ) is set equal to FullChargeCapacity( ). 5.6.2 Charge Inhibit and Suspend The bq27520-G2 can indicate when battery temperature has fallen below or risen above predefined thresholds Charge Inhibit Temp Low or Charge Inhibit Temp High, respectively. In this mode, the [CHG_INT] bit is set and the BAT_GD pin is deserted to indicate this condition. The [CHG_INT] bit is cleared and the BAT_GD pin is asserted once the battery temperature returns to the range [Charge Inhibit Temp Low + Temp Hys, Charge Inhibit Temp High – Temp Hys]. 32 FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com When PFC = 1, the bq27520-G2 can indicate when battery temperature has fallen below or risen above predefined thresholds Suspend Low Temp or Suspend High Temp, respectively. In this mode, the [XCHG] bit is set to indicate this condition. The [XCHG] bit is cleared once the battery temperature returns to the range [Charge Inhibit Temp Low + Temp Hys, Charge Inhibit Temp High – Temp Hys]. The charging should not start when the temperature is below the Charge Inhibit Temp Low or above the Charge Inhibit Temp High. The charging can continue if the charging starts inside the window [Charge Inhibit Temp Low, Charge Inhibit Temp High] until the temperature is either below Suspend Low Temp or above the Suspend Low Temp. Therefore, the window [Charge Inhibit Temp Low, Charge Inhibit Temp High] must be inside the window of [Suspend Low Temp, Suspend High Temp]. 5.7 POWER MODES The bq27520-G2 has different power modes: BAT INSERT CHECK, NORMAL, SLEEP+, SLEEP and HIBERNATE. In NORMAL mode, the bq27520-G2 is fully powered and can execute any allowable task. In SLEEP+ mode, both low frequency and high frequency oscillators are active. Although the SLEEP+ has higher current consumption than the SLEEP mode, it is also a reduced power mode. In SLEEP mode, the fuel gauge turns off the high frequency oscillator and exists in a reduced-power state, periodically taking measurements and performing calculations. In HIBERNATE mode, the fuel gauge is in a low power state, but can be woken up by communication or certain I/O activity. Finally, the BAT INSERT CHECK mode is a powered-up, but low-power halted, state, where the bq27520-G2 resides when no battery is inserted into the system. The relationship between these modes is shown in Figure 5-1. 5.7.1 BAT INSERT CHECK Mode This mode is a halted-CPU state that occurs when an adapter, or other power source, is present to power the bq27520-G2 (and system), yet no battery has been detected. Depending on the setting of the [BIE] bit in the Operation Configuration B dataflash register, the bq27520-G2 will detect battery insertion either through use of the thermistor network and BI/TOUT pin, or the host can use the BAT_INSERT and BAT_REMOVE commands to inform the battery presence status. When battery insertion is detected, a series of initialization activities begin, which include: OCV measurement, setting the BAT_GD pin, and selecting the appropriate battery profiles. Some commands, issued by a system processor, can be processed while the bq27520-G2 is halted in this mode. The gauge will wake up to process the command, then return to the halted state awaiting battery insertion. 5.7.2 NORMAL MODE The fuel gauge is in NORMAL mode when not in any other power mode. During this mode, AverageCurrent( ), Voltage( ) and Temperature( ) measurements are taken, and the interface data set is updated. Decisions to change states are also made. This mode is exited by activating a different power mode. Because the gauge consumes the most power in NORMAL mode, the Impedance Track™ algorithm minimizes the time the fuel gauge remains in this mode. 5.7.3 SLEEP MODE SLEEP mode is entered automatically if the feature is enabled (Operation Configuration [SLEEP] = 1) and AverageCurrent( ) is below the programmable level Sleep Current. Once entry into SLEEP mode has been qualified, but prior to entering it, the bq27520-G2 performs an coulomb counter autocalibration to minimize offset. During SLEEP mode, the bq27520-G2 periodically takes data measurements and updates its data set. However, a majority of its time is spent in an idle condition. FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 33 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com The bq27520-G2 exits SLEEP if any entry condition is broken, specifically when (1) AverageCurrent( ) rises above Sleep Current, or (2) a current in excess of IWAKE through RSENSE is detected. In the event that a battery is removed from the system while a charger is present (and powering the gauge), Impedance Track™ updates are not necessary. Hence, the fuel gauge enters a state that checks for battery insertion and does not continue executing the Impedance Track™ algorithm. 5.7.4 SLEEP+ MODE Compared to the SLEEP mode, SLEEP+ mode has the high frequency oscillator in operation. The communication delay could be eliminated. The SLEEP+ is entered automatically if the feature is enabled (CONTROL STATUS [SNOOZE] = 1) and AverageCurrent( ) is below the programmable level Sleep Current. During SLEEP+ mode, the bq27520-G2 periodically takes data measurements and updates its data set. However, a majority of its time is spent in an idle condition. The bq27520-G2 exits SLEEP+ if any entry condition is broken, specifically when (1) any communication activity with the gauge, or (2) AverageCurrent( ) rises above Sleep Current, or (3) a current in excess of IWAKE through RSENSE is detected. 5.7.5 HIBERNATE MODE HIBERNATE mode should be used when the system equipment needs to enter a low-power state, and minimal gauge power consumption is required. This mode is ideal when a system equipment is set to its own HIBERNATE, SHUTDOWN, or OFF modes. Before the fuel gauge can enter HIBERNATE mode, the system must set the [HIBERNATE] bit of the CONTROL_STATUS register. The gauge waits to enter HIBERNATE mode until it has taken a valid OCV measurement and the magnitude of the average cell current has fallen below Hibernate Current. The gauge can also enter HIBERNATE mode if the cell voltage falls below Hibernate Voltage and a valid OCV measurement has been taken. The gauge will remain in HIBERNATE mode until the system issues a direct I2C command to the gauge or a POR occurs. I2C Communication that is not directed to the gauge will not wake the gauge. It is important that BAT_GD be deserted status (no battery charging/discharging). This prevents a charger application from inadvertently charging the battery before an OCV reading can be taken. It is the system’s responsibility to wake the bq27520-G2 after it has gone into HIBERNATE mode. After waking, the gauge can proceed with the initialization of the battery information (OCV, profile selection, etc.) 5.8 5.8.1 POWER CONTROL WAKE-UP COMPARATOR The wake up comparator is used to indicate a change in cell current while the bq27520-G2 is in SLEEP mode. Operation Configuration uses bits [RSNS1–RSNS0] to set the sense resistor selection. Operation Configuration also uses the [IWAKE] bit to select one of two possible voltage threshold ranges for the given sense resistor selection. An internal interrupt is generated when the threshold is breached in either the charge or discharge direction. Setting both [RSNS1] and [RSNS0] to 0 disables this feature. Table 5-7. IWAKE Threshold Settings (1) (1) 34 RSNS1 RSNS0 IWAKE Vth(SRP–SRN) 0 0 0 Disabled 0 0 1 Disabled The actual resistance value vs the setting of the sense resistor is not important, just the actual voltage threshold when calculating the configuration. The voltage thresholds are typical values under room temperature. FUNCTIONAL DESCRIPTION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Table 5-7. IWAKE Threshold Settings(1) (continued) 5.8.2 RSNS1 RSNS0 IWAKE Vth(SRP–SRN) 0 1 0 1.0 mV or –1.0 mV 0 1 1 2.2 mV or –2.2 mV 1 0 0 2.2 mV or –2.2 mV 1 0 1 4.6 mV or –4.6 mV 1 1 0 4.6 mV or –4.6 mV 1 1 1 9.8 mV or –9.8 mV FLASH UPDATES Data Flash can only be updated if Voltage( ) ≥ Flash Update OK Voltage. Flash programming current can cause an increase in LDO dropout. The value of Flash Update OK Voltage should be selected such that the bq27520-G2 VCC voltage does not fall below its minimum of 2.4 V during Flash write operations. 5.9 AUTOCALIBRATION The bq27520-G2 provides an autocalibration feature that measures the voltage offset error across SRP and SRN as operating conditions change. It subtracts the resulting offset error from normal sense resistor voltage, VSR, for maximum measurement accuracy. Autocalibration of the coulomb counter begins on entry to SLEEP mode, except if Temperature( ) is ≤ 5°C or Temperature( ) ≥ 45°C. The fuel gauge also performs a single offset when (1) the condition of AverageCurrent( ) ≤ 100 mA and (2) {voltage change since last offset calibration ≥ 256 mV} or {temperature change since last offset calibration is greater than 8°C for ≥ 60 s}. Capacity and current measurements continue at the last measured rate during the offset calibration when these measurements cannot be performed. If the battery voltage drops more than 32 mV during the offset calibration, the load current has likely increased; hence, the offset calibration is aborted. 6 APPLICATION-SPECIFIC INFORMATION 6.1 6.1.1 BATTERY PROFILE STORAGE AND SELECTION Common Profile Aspects When a battery pack is removed from host equipment, the bq27520-G2 maintains some of the battery information in case the battery is re-inserted. This way, the Impedance Track™ algorithm has a means of recovering battery-status information, thereby maintaining good state-of-charge (SOC) estimates. Two default battery profiles are available to store battery information. They are used to provide the Impedance Track™ algorithm with the default information on two possible battery types expected to be used with the end-equipment. These default profiles can be used to support batteries of different chemistry, same chemistry but different capacities, or same chemistry but different models. Default profiles are programmed by the end-equipment manufacturer. However, only one of the default profiles can be selected, and this selection cannot be changed during end-equipment operation. In addition to the default profiles, the fuel gauge maintains two profiles PACK0 and PACK1. These tables hold dynamic battery data, and keep track of the status for up to two of the most recent batteries used. In most cases, the fuel gauge can manage the information on two removable battery packs. APPLICATION-SPECIFIC INFORMATION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 35 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 6.1.2 www.ti.com Activities Upon Pack Insertion 6.1.2.1 First OCV and Impedance Measurement At power-up the BAT_GD pin is inactive, so that the system might not obtain power from the battery (this depends on actual implementation). In this state, the battery should be put in a condition with load current less than C/20. Next, the bq27520-G2 measures its first open-circuit voltage (OCV) via the BAT pin. The [OCVCMDCOMP] bit will set once the OCV measurement is completed. Depending on the load current, the [OCVFAIL] bit indicates whether the OCV reading is valid. From the OCV(SOC) table, the SOC of the inserted battery is found. Then the BAT_GD pin is made active, and the impedance of the inserted battery is calculated from the measured voltage and the load current: Z(SOC) = ( OCV(SOC) – V ) / I. This impedance is compared with the impedance of the dynamic profiles, Packn, and the default profiles, Defn, for the same SOC (the letter n depicts either a 0 or 1).The [INITCOMP] bit will be set afterwards and the OCV command could be issued 6.1.3 Reading Application Status The Application Status data flash location contains cell profile status information, and can be read using the ApplicationStatus( ) extended command (0x6a). The bit configuration of this function/location is shown in Table 6-1. Table 6-1. ApplicationStatus( ) Bit Definitions. Application Configuration Byte bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 — — — — — — — LU_ PROF LU_PROF = Last profile used by fuel gauge. Cell0 last used when cleared. Cell1 last used when set. Default is 0. 6.2 APPLICATION-SPECIFIC FLOW AND CONTROL The bq27520-G2 supports only one type of battery profile. This profile is stored in both the Def0 and Def1 profiles. When a battery pack is inserted for the first time, the default profile is copied into the Packn profiles. Then the Impedance Track™ algorithm begins gas gauging, regularly updating Packn as the battery is used. When an existing pack is removed from the bq27520-G2 and a different (or same) pack is inserted, cell impedance is measured immediately after battery detection (see Section 6.1.2.1., First OCV and Impedance Measurement). The bq27520-G2 chooses the profile which is closest to the measured impedance, starting with the Packn profiles. That is, if the measured impedance matches Pack0, then the Pack0 profile is used. If the measured impedance matches Pack1, then the Pack1 profile is used. If the measured impedance does not match the impedance stored in either Pack0 or Pack1, the battery pack is deemed new (none of the previously used packs). Either Def0/Def1 profile is copied into either the Pack0 or Pack1 profile, overwriting the oldest Packn profile. 36 APPLICATION-SPECIFIC INFORMATION Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 7 COMMUNICATIONS I2C INTERFACE 7.1 The bq27520-G2 supports the standard I2C read, incremental read, quick read, one byte write, and incremental write functions. The 7 bit device address (ADDR) is the most significant 7 bits of the hex address and is fixed as 1010101. The first 8-bits of the I2C protocol will; therefore, be 0xAA or 0xAB for write or read, respectively. Host generated S ADDR[6:0] 0 A bq27520 generated CMD [7:0] A DATA [7:0] A P S ADDR[6:0] (a) 1-byte write S ADDR[6:0] 0 A 1 A DATA [7:0] N P (b) quick read CMD [7:0] A Sr ADDR[6:0] 1 A DATA [7:0] N P (c) 1- byte read S ADDR[6:0] 0 A CMD [7:0] A Sr ADDR[6:0] 1 A DATA [7:0] A ... DATA [7:0] N P (d) incremental read S ADDR[6:0] 0 A CMD[7:0] A DATA [7:0] A DATA [7:0] A ... A P (e) incremental write (S = Start , Sr = Repeated Start , A = Acknowledge , N = No Acknowledge , and P = Stop). The “quick read” returns data at the address indicated by the address pointer. The address pointer, a register internal to the I2C communication engine, will increment whenever data is acknowledged by the bq27520-G2 or the I2C master. “Quick writes” function in the same manner and are a convenient means of sending multiple bytes to consecutive command locations (such as two-byte commands that require two bytes of data) The following command sequences are not supported: Attempt to write a read-only address (NACK after data sent by master): Attempt to read an address above 0x6B (NACK command): COMMUNICATIONS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 37 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 7.2 www.ti.com I2C Time Out The I2C engine will release both SDA and SCL if the I2C bus is held low for the time defined by I2C Timeout times 0.5 second. If the bq27520-G2 was holding the lines, releasing them will free for the master to drive the lines. If an external condition is holding either of the lines low, the I2C engine will enter the low power sleep mode. 7.3 I2C Command Waiting Time To make sure the correct results of a command with the 400KHz I2C operation, a proper waiting time should be added between issuing command and reading results. For subcommands, the following diagram shows the waiting time required between issuing the control command the reading the status with the exception of checksum and OCV commands. A 100ms waiting time is required between the checksum command and reading result, and a 1.2 second waiting time is required between the OCV command and result. For read-write standard command, a minimum of 2 seconds is required to get the result updated. For read-only standard commands, there is no waiting time required, but the host should not issue all standard commands more than two times per second. Otherwise, the gauge could result in a reset issue due to the expiration of the watchdog timer. S ADDR [6:0] 0 A CMD [7:0] A DATA [7:0] S ADDR [6:0] 0 A CMD [7:0] A Sr ADDR [6:0] A 1 A DATA [7:0] DATA [7:0] A P A 66ms DATA [7:0] N P DATA [7:0] A 66ms Waiting time between control subcommand and reading results S ADDR [6:0] DATA [7:0] 0 A A CMD [7:0] DATA [7:0] A Sr N P ADDR [6:0] 1 A DATA [7:0] A 66ms Waiting time between continuous reading results 7.4 I2C Clock Stretching I2C clock stretches can occur during all modes of fuel gauge operation. In the SLEEP and HIBERNATE modes, a short clock stretch will occur on all I2C traffic as the device must wake-up to process the packet. In NORMAL and SLEEP+ modes, clock stretching will only occur for packets addressed for the fuel gauge. The timing of stretches will vary as interactions between the communicating host and the gauge are asynchronous. The I2C clock stretches may occur after start bits, the ACK/NAK bit and first data bit transmit on a host read cycle. The majority of clock stretch periods are small (<= 4mSec) as the I2C interface peripheral and CPU firmware perform normal data flow control. However, less frequent but more significant clock stretch periods may occur when data flash (DF) is being written by the CPU to update the resistance (Ra) tables and other DF parameters such as Qmax. Due to the organization of DF, updates need to be written in data blocks consisting of multiple data bytes. An Ra table update requires erasing a single page of DF, programming the updated Ra table and a flag. The potential I2C clock stretching time is 24ms max. This includes 20ms page erase and 2ms row programming time (x2 rows). The Ra table updates occur during the discharge cycle and at up to 15 resistance grid points that occur during the discharge cycle. A DF block write typically requires a max of 72ms. This includes copying data to a temporary buffer and updating DF. This temporary buffer mechanism is used to protect from power failure during a DF update. The first part of the update requires 20ms time to erase the copy buffer page, 6 ms time to write the data into the copy buffer and the program progress indicator (2ms for each individual write). The second part of the update is writing to the DF and requires 44ms DF block update time. This includes a 20ms each page erase for two pages and 2ms each row write for two rows. 38 COMMUNICATIONS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com In the event that a previous DF write was interrupted by a power failure or reset during the DF write, an additional 44ms max DF restore time is required to recover the data from a previously interrupted DF write. In this power failure recovery case, the total I2C clock stretching is 116ms max. Another case where I2C clock stretches is at the end of discharge. The update to the last discharge data will go through the DF block update twice because two pages are used for the data storage. The clock stretching in this case is 144ms max. This occurs if there has been a Ra table update during the discharge. COMMUNICATIONS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 39 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 8 REFERENCE SCHEMATICS 8.1 SCHEMATIC 40 REFERENCE SCHEMATICS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com 8.2 Package Dimensions D E Max = 2640µm Max = 1986µm Min = 2580µm Min = 1926µm REFERENCE SCHEMATICS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 41 bq27520-G2 SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011 www.ti.com Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Original (March 2011) to A Revision ....................................................................................................... Page • • • • • • • • • • • • • • • • • • • 42 Added text to the General Description "see Section 4.3: "MANUFACTURER INFORMATION BLOCKS" .............. 9 Added text to the General Description "see Section 5.7 "POWER MODES" ................................................ 9 Changed the FACTORY RESTORE section: FROM: "SOC_INT..in progress" TO: "If Operation..in progress." ......................................................................................................................................... 13 Added row in Table 4-7: Configuration, Subclass ID: 36, Offset 13, DOD at EOC ........................................ 22 Deleted row from Table 4-7: Configuration, Subclass ID 56 Full Reset Counter .......................................... 22 Changed Table 4-7: Configuration 64, Offset 11 - Default Value FROM: 0x43 TO: 0x4B ................................ 23 Changed Table 4-7: Configuration 64, Offset 12 - Default Value FROM: 0x24 TO: 0x2C ............................... 23 Changed Table 4-7.: FROM: Configuration Subclass ID: 68 Max Res Factor TO: Gas Gauging Subclass ID:80, Max Res Factor ..................................................................................................................... 23 Changed Table 4-7.: FROM: Configuration Subclass ID: 68 Min Res Factor TO: Gas Gauging Subclass ID:80, Min Res Factor ...................................................................................................................... 23 Added row to Table 4-7. Gas Gauging, Offset 47, Term V Delta ............................................................ 23 Added row to Table 4-7. Gas Gauging, Offset 50, ResRelax Time .......................................................... 23 Changed in Table 4-7, Gas Gauging, FROM: Offset 50 through 60 TO: 54 through 72. ................................. 23 Added row to Table 4-7. Gas Gauging, Offset 74, Max Res Scale .......................................................... 23 Added row to Table 4-7. Gas Gauging, Offset 76, Min Res Scale ........................................................... 23 Added row to Table 4-7. Gas Gauging, Offset 78, Fast Scale Start SOC .................................................. 23 Added row to Table 4-7. Gas Gauging, Offset 24, T Rise .................................................................... 24 Added row to Table 4-7. Gas Gauging, Offset 26, T Time Constant ........................................................ 24 Changed Table 4-7: Calibration 104, Offset 8 - Default Value FROM: -0.088 TO: -0.58 ................................. 24 Added row to Table 5-6: "Factory Restore." .................................................................................... 31 REFERENCE SCHEMATICS Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s) :bq27520-G2 PACKAGE OPTION ADDENDUM www.ti.com 15-Apr-2017 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish MSL Peak Temp (2) (6) (3) Op Temp (°C) Device Marking (4/5) BQ27520YZFR-G2 NRND DSBGA YZF 15 3000 Green (RoHS & no Sb/Br) SNAGCU Level-1-260C-UNLIM -40 to 85 BQ27520G BQ27520YZFT-G2 NRND DSBGA YZF 15 250 Green (RoHS & no Sb/Br) SNAGCU Level-1-260C-UNLIM -40 to 85 BQ27520G HPA01025YZFR NRND DSBGA YZF 15 3000 Green (RoHS & no Sb/Br) SNAGCU Level-1-260C-UNLIM -40 to 85 BQ27520G (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 15-Apr-2017 continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 18-Feb-2016 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) BQ27520YZFR-G2 DSBGA YZF 15 3000 180.0 8.4 BQ27520YZFT-G2 DSBGA YZF 15 250 180.0 8.4 Pack Materials-Page 1 B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant 2.1 2.76 0.81 4.0 8.0 Q1 2.1 2.76 0.81 4.0 8.0 Q1 PACKAGE MATERIALS INFORMATION www.ti.com 18-Feb-2016 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) BQ27520YZFR-G2 DSBGA YZF 15 3000 182.0 182.0 20.0 BQ27520YZFT-G2 DSBGA YZF 15 250 182.0 182.0 20.0 Pack Materials-Page 2 PACKAGE OUTLINE YZF0015 DSBGA - 0.625 mm max height SCALE 6.500 DIE SIZE BALL GRID ARRAY B A E BALL A1 CORNER D C 0.625 MAX SEATING PLANE 0.35 0.15 0.05 C BALL TYP 1 TYP SYMM E D SYMM 2 TYP C B 0.5 TYP A 15X 0.015 0.35 0.25 C A B 1 2 3 0.5 TYP 4219381/A 02/2017 NanoFree Is a trademark of Texas Instruments. NOTES: 1. All linear dimensions are in millimeters. Any dimensions in parenthesis are for reference only. Dimensioning and tolerancing per ASME Y14.5M. 2. This drawing is subject to change without notice. TM 3. NanoFree package configuration. www.ti.com EXAMPLE BOARD LAYOUT YZF0015 DSBGA - 0.625 mm max height DIE SIZE BALL GRID ARRAY (0.5) TYP 15X ( 0.245) 1 3 2 A (0.5) TYP B SYMM C D E SYMM LAND PATTERN EXAMPLE EXPOSED METAL SHOWN SCALE:30X 0.05 MAX ( 0.245) METAL SOLDER MASK OPENING EXPOSED METAL 0.05 MIN METAL UNDER SOLDER MASK EXPOSED METAL ( 0.245) SOLDER MASK OPENING NON-SOLDER MASK DEFINED (PREFERRED) SOLDER MASK DEFINED SOLDER MASK DETAILS NOT TO SCALE 4219381/A 02/2017 NOTES: (continued) 4. Final dimensions may vary due to manufacturing tolerance considerations and also routing constraints. For more information, see Texas Instruments literature number SNVA009 (www.ti.com/lit/snva009). www.ti.com EXAMPLE STENCIL DESIGN YZF0015 DSBGA - 0.625 mm max height DIE SIZE BALL GRID ARRAY (0.5) TYP (R0.05) TYP 15X ( 0.25) 1 2 3 A (0.5) TYP B METAL TYP SYMM C D E SYMM SOLDER PASTE EXAMPLE BASED ON 0.1 mm THICK STENCIL SCALE:40X 4219381/A 02/2017 NOTES: (continued) 5. Laser cutting apertures with trapezoidal walls and rounded corners may offer better paste release. www.ti.com IMPORTANT NOTICE Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. TI’s published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and services. Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyers and others who are developing systems that incorporate TI products (collectively, “Designers”) understand and agree that Designers remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products used in or for Designers’ applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will thoroughly test such applications and the functionality of such TI products as used in such applications. TI’s provision of technical, application or other design advice, quality characterization, reliability data or other services or information, including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any way, Designer (individually or, if Designer is acting on behalf of a company, Designer’s company) agrees to use any particular TI Resource solely for this purpose and subject to the terms of this Notice. TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections, enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically described in the published documentation for a particular TI Resource. Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. TI RESOURCES ARE PROVIDED “AS IS” AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM, INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949 and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements. Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use. Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S. TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product). Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications and that proper product selection is at Designers’ own risk. Designers are solely responsible for compliance with all legal and regulatory requirements in connection with such selection. Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer’s noncompliance with the terms and provisions of this Notice. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2017, Texas Instruments Incorporated