MPD MI1024S-24ERU-xxx Wide 4:1 input, 10w miniature 1 x 1 dc/dc converter Datasheet

MI1000ERU Series
Wide 4:1 Input, 10W
Miniature 1” x 1”
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 10W Output Power
Parameter
• 4:1 Input Range
Input Voltage Range
• EN 60950 Approved
Input Start-up Threshold
• Miniature 1” x 1” Case
• Single & Dual Outputs
Under Voltage Shutdown
Reflected Ripple Current
• 1,500 VDC Isolation
• >1 MHour MTBF
Input Filter
• Chassis Mount Available
Parameter
Output Voltage Accuracy
Output Voltage Balance
• DIN Rail Mount Available
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
24 VDC Input
48 VDC Input
24 VDC Input
5.5
48 VDC Input 14.0
24 VDC Input
48 VDC Input
Pi (␲) Filter
Typ.
24.0
48.0
Max.
36.0
75.0
9.0
18.0
6.5
15.5
40
30
Units
VDC
VDC
VDC
mA
Output
Line Regulation, VIN = Min to Max
Load Regulation, IOUT = 5% to 100%
Cross Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time , See Note 4
Transient Response Deviation
Temperature Coefficient
Over Voltage Protection
Output Over Load Protection
Output Short Circuit
Conditions
IOUT = 5% to 100%
Dual Outputs, Balanced Loads
Positive Output
Negative Output
Positive Output
Negative Output
See Note 2
See Note 3
Min.
Typ.
±1.0
±0.5
±0.2
±0.5
±0.5
±0.5
40
300
±3.0
25% Load Step Change
110
110
140
Continuous (Autorecovery)
Max.
±3.0
±1.5
±0.5
±1.0
±1.0
±1.5
±5.0
80
500
±5.0
±0.03
160
190
Units
%
%
%
%
%
mV P - P
µSec
%
%/ºC
%VOUT
%IOUT
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 0.1V
Min.
1,500
1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Max.
+85
+125
Units
ºC
ºC
95
%
1,000
350
Environmental
Cost Cutter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
-55
Free Air Convection
RH, Non-condensing
Ambient
See Mechanical Diagrams (Pages 2 & 4)
Aluminum (UL94-V0)
See Mechanical Diagrams (Pages 2 & 4)
Remote On/Off
Parameter
Unit On
Unit Off
Off Idle Current
Conditions
See Note 5
See Note 5
Min.
3.5
0
Typ.
6.0
Max.
12.0
1.2
10.0
Units
VDC
VDC
mA
Reliability Specifications
Parameter
MTBF
Vibration, EN 60068
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
MHours
10-55 Hz, 10G, 30 Min along X, Y, and Z Axis
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
Typ.
Max.
50.0
100.0
300
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MI1024S-03ERU-xxx
MI1024S-05ERU-xxx
MI1024S-09ERU-xxx
MI1024S-12ERU-xxx
MI1024S-15ERU-xxx
MI1024S-24ERU-xxx
MI1024D-05ERU-xxx
MI1024D-09ERU-xxx
MI1024D-12ERU-xxx
MI1024D-15ERU-xxx
MI1024D-24ERU-xxx
MI1048S-03ERU-xxx
MI1048S-05ERU-xxx
MI1048S-12ERU-xxx
MI1048S-15ERU-xxx
MI1048S-24ERU-xxx
MI1048D-05ERU-xxx
MI1048D-12ERU-xxx
MI1048D-15ERU-xxx
MI1048D-24ERU-xxx
Voltage (VDC)
Nominal
Range
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
Output
Current (mA)
Full-Load No-Load
418
5
502
5
484
5
478
5
478
5
473
5
502
5
484
5
478
5
478
5
478
5
209
4
251
4
239
4
239
4
237
4
251
4
239
4
239
4
239
4
Notes:
1. The specified maximum capacitive load is for each output.
2. Cross regulation is measured with the main output set at 50% load. The second output is varied
from 10% to 100% load.
3. When measuring output ripple & noise, it is recommended that external ceramic capacitors
(10 µF & 1 µF) be connected in parallel from the +VOUT to the -VOUT pins for single output
units and from each output to common for dual output models.
4. Transient recovery is measured to within a 1% error band for a load step change of 25%.
5. The voltage at the Remote On/Off pin (Pin 6) is referenced to the -VIN input (Pin 1). If the on/
off pin is left open, the unit operates. If it is grounded, the unit will shut off.
6. Operation at no-load will not damage these units. However, they may not meet all specifications.
The recommended minimum load is given in the model selection table above.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the
Model Selection table above for the correct rating.
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
2,400
2,000
1,111
833
667
416
±1,000
±555
±416
±333
±208
2,400
2,000
833
667
416
±1,000
±416
±333
±208
Capacitive
Rating
Efficiency Fuse
Load
Slow-Blow
(%, Typ)
(mA)
(µF Max)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
2,200
2,200
680
470
330
100
1,000
680
470
330
100
2,200
2,200
470
330
100
1,000
470
330
100
79
83
86
87
87
88
83
86
87
87
87
79
83
87
87
88
83
87
87
87
2,000
2,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
1,000
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Single Output
-VIN
+VIN
+VOUT
No Pin
-VOUT
Remote On/Off
Pin
1
2
3
4
5
6
Dual Output
-VIN
+VIN
+VOUT
Common
-VOUT
Remote On/Off
Weight: 0.53 Oz (15g)
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
Parameter
Radiated Emissions, See Note 1
Conducted Emissions, See Note 1
ESD
RS
EFT, See Note 2
Surge, See Note 3
CS
Voltage Dips
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Criteria
B
A
B
B
A
B
Notes:
1. All units will meet class A with the addition of the capacitors shown in the
“Simple Connection” diagram. To meet the requirements of Class B, refer
to the “Typical Connection” circuit. Contact the factory for more information.
2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are
needed, as shown in the “Typical Connection” diagram. Contact the factory
for more information.
3. To meet the requirements of EN 61000-4-5 (±2 kV ), external components are
needed, as shown in the “Typical Connection” diagram. Contact the factory
for more information.
Level
Class A
Class A
±4 kV Contact
10V/m
±2 kV
±2 kV
3 Vrms
0% - 70%
Simple Connection
The diagram at left illustrates a typical connection
of the MI10xxS-xxERU series. Capacitors C1
and C2 are filtering components. They are required
to meet the EN 55022 requirements for Class A.
The recommended component values are given in
the table below.
VIN
C1 (µF)
C3 (µF)
24 VDC
100
10
48 VDC
10 - 47
10
Typical Connection
The diagram above illustrates a typical dual output connection of the
MI10xxD-xxERU series for an application that requires compliance to input
surge and EMC standards EN 55022 and EN 61000 (as specified above). Some
notes on these components are:
1. An external MOV is recommended on the input to protect the unit in the event
of a surge. A recommended value is given in the table at right.
2. The output filtering capacitors (C3 & C4) are high frequency, low resistance
electrolytic capacitors. Care must be taken in choosing these capacitors not
to exceed the capacitive load specification for the unit. Voltage derating of
capacitors should be 80% or above.
3. Suggested component values are:
Component
MOV
C1
C2
C3
C4
LDM1
CY1, CY2
VIN: 24V
S14K35
330µF/50V
1 µF/50V
10 µF
10 µF
4.7 µH
1 nF/2 kV
VIN: 48V
S14K60
330µF/100V
1 µF/100V
10 µF
10 µF
4.7 µH
1 nF/2 kV
4. In many applications, simply adding input/output capacitors will enhance the input surge protection & and reduce output ripple sufficiently. In this case, capacitors C1, C3 and C4 could be connected as
shown above, without the other filter components. Recommended
capacitor values are given in the table at left.
5. It is recommended that an external fuse be used. The recommended fuse
is shown in the model chart on page 2.
Typical Board Layout: Single Output With Filtering Components
The diagrams at left shows typical PC
board layouts for the MI10xxx-xxERU
with the input surge and filter components shown above.
Typical Board Layout: Dual Output With Filtering Components
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
The minimum distance between the
bonding pads for capacitors CY1 and CY2
must be > 2mm,
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions: With A2S Adapter Board
For the A2S adapter board option, add
suffix “A2S” to the model number
(i.e. MI1024S-15ERU-A2S)
Pin Connections
Pin Single Output
1 Remote On/Off
2
-VIN
3
+VIN
4
-VOUT
5 No Connection
6
+VOUT
Pin Dual Output
1 Remote On/Off
2
-VIN
3
+VIN
4
-VOUT
5
Common
6
+VOUT
Weight: 1.237 Oz (35g)
Mechanical Dimensions: With A4S Adapter Board
For the A4S adapter board option, add
suffix “A4S” to the model number
(i.e. MI1048D-12ERU-A4S)
Pin Connections
Pin Single Output
1 Remote On/Off
2
-VIN
3
+VIN
4
-VOUT
5 No Connection
6
+VOUT
Pin Dual Output
1 Remote On/Off
2
-VIN
3
+VIN
4
-VOUT
5
Common
6
+VOUT
Weight: 1.944 Oz (55g)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Wire Range: 24 - 12 AWG
• Tolerance x.xx = ±0.02 (±0.50)
FAX: (781) 344-8481
•
E-Mail: [email protected]