Vicor BCM6123TD1E5126T00 Isolated fixed-ratio dc-dc converter Datasheet

BCM® Bus Converter
BCM6123xD1E5126yzz
®
C
S
US
C
NRTL
US
Isolated Fixed-Ratio DC-DC Converter
Features & Benefits
Product Ratings
• Up to 25.7A continuous secondary current
• Up to 1876W/in3 power density
• 97.9% peak efficiency
VPRI = 380V (260 – 410V)
ISEC = up to 25.7A
VSEC = 47.5V (32.5 – 51.3V)
(no load)
K = 1/8
• 4,242VDC isolation
• Parallel operation for multi-kW arrays
Product Description
• OV, OC, UV, short circuit and thermal protection
The BCM6123xD1E5126yzz Bus Converter (BCM®) is a high
efficiency Sine Amplitude Converter™ (SAC™), operating from
a 260 to 410VDC primary bus to deliver an isolated, ratiometric
secondary voltage from 32.5 to 51.3VDC.
• 6123 through-hole ChiP package
■■2.494” x 0.898” x 0.284”
(63.34mm x 22.80mm x 7.21mm)
• PMBus™ management interface*
Typical Applications
• 380VDC Power Distribution
• High End Computing Systems
• Automated Test Equipment
• Industrial Systems
• High Density Power Supplies
• Communications Systems
• Transportation
The BCM6123xD1E5126yzz offers low noise, fast transient
response, and industry leading efficiency and power density. In
addition, it provides an AC impedance beyond the bandwidth of
most downstream regulators, allowing input capacitance normally
located at the input of a PoL regulator to be located at the primary
side of the BCM module. With a primary to secondary K factor
of 1/8, that capacitance value can be reduced by a factor of 64x,
resulting in savings of board area, material and total system cost.
Leveraging the thermal and density benefits of Vicor ChiP
packaging technology, the BCM module offers flexible thermal
management options with very low top and bottom side thermal
impedances. Thermally-adept ChiP-based power components,
enable customers to achieve low cost power system solutions
with previously unattainable system size, weight and efficiency
attributes, quickly and predictably.
This product can operate in reverse direction, at full rated power,
after being previously started in forward direction.
* When used with D44TL1A0 and I13TL1A0
BCM® Bus Converter
Page 1 of 30
Rev 1.3
09/2017
BCM6123xD1E5126yzz
Typical Application
BCM
TM
EN
enable/disable
switch
SW1
VAUX
F1
VPRI
+VPRI
+VSEC
–VPRI
–VSEC
CPRI
POL
GND
PRIMARY
SECONDARY
ISOLATION BOUNDRY
BCM6123xD1E5126y00 at Point of load
BCM
SER-OUT
SER-OUT
EN
SER-IN
enable/disable
switch
SER-IN
FUSE
VPRI
C
+VPRI
+VSEC
–VPRI
–VSEC
POL
I_BCM_ELEC
PRIMARY
SOURCE_RTN
SECONDARY
Digital
Supervisor
ISOLATION BOUNDRY
Digital Isolator
D44TL1A0
I13TL1A0
NC
PRI_OUT_A
Host µC
SEC_IN_A
VDDB
SEC_IN_B
TXD
VDD
PRI_IN_C
SEC_OUT_C
RXD
PRI_COM
SEC_COM
SER-IN
t
+
PRI_OUT_B
–
V
EXT
SER-OUT
SGND
SGND
PMBus
PMBus
SGND
SGND
SGND
BCM6123xD1E5126y01 at Point of load
BCM® Bus Converter
Page 2 of 30
Rev 1.3
09/2017
BCM6123xD1E5126yzz
Typical Application
PRM
BCM
ENABLE
enable/disable
switch
TM/SER-OUT
SGND
VAUX/SER-IN
R
FUSE
V
C
PRI
+VPRI
+VSEC
–VPRI
–VSEC
PRIMARY
R
TRIM_PRM
SHARE/
CONTROL NODE
OUT
+OUT
VC
PC
IFB
C
R
O_PRM_DAMP
I_PRM_DAMP
L
V
TM
VTM Start Up Pulse
VC
AL_PRM
SGND
I_BCM_ELEC
SOURCE_RTN
R
VTM
Adaptive Loop Temperature Feedback
VT
AL
EN
enable/disable
switch
VAUX
REF/
REF_EN
TRIM
I_PRM_FLT
R
+IN
+OUT
–IN
–OUT
L
I_PRM_CER
SGND
LOAD
O_VTM_CER
+IN
O_PRM_FLT
C
O_PRM_CER
–IN
–OUT
PRIMARY
SECONDARY
SECONDARY
LOAD_RTN
ISOLATION BOUNDRY
ISOLATION BOUNDRY
SGND
BCM6123xD1E5126yzz + PRM + VTM, Adaptive Loop Configuration
V
REF
TM/SER-OUT
VPRI
C
I_BCM_ELEC
SOURCE_RTN
+VPRI
+VSEC
–VPRI
–VSEC
SHARE/
CONTROL NODE
VC
IFB
C
VTM
SGND
V+
SGND
External Current Sense
I_PRM_ELEC
–IN
SGND
SECONDARY
–OUT
VC
PC
V–
VOUT
–IN
+OUT
TM
VTM Start up Pulse
+OUT
R
L
C
O_PRM_DAMP
+IN
O_PRM_FLT
C
O_PRM_CER
–IN
–OUT
PRIMARY
SECONDARY
ISOLATION BOUNDRY
ISOLATION BOUNDRY
SGND
BCM6123xD1E5126yzz + PRM + VTM, Remote Sense Configuration
BCM® Bus Converter
Page 3 of 30
Voltage Sense and Error Amplifier
(Differential)
Voltage Reference with Soft Start
+IN
+IN
I_PRM_FLT
PRIMARY
VT
I_PRM_DAMP
L
SGND
OUT
GND
REF/
REF_EN
AL
SGND
R
FUSE
IN
VAUX
TRIM
SGND
VAUX/SER-IN
REF 3312
ENABLE
enable/disable
switch
EN
enable/disable
switch
SGND
PRM
Rev 1.3
09/2017
Voltage Sense
BCM
O_VTM_CER
LOAD
BCM6123xD1E5126yzz
Pin Configuration
TOP VIEW
1
2
+VPRI
A
A’
+VSEC
TM/SER-OUT
B
B’
–VSEC
EN
C
VAUX/SER-IN
D
–VPRI
E
C’ +VSEC
D’
–VSEC
6123 ChiP Package
Pin Descriptions
Power Pins
Pin Number
Signal Name
Type
Function
A1
+VPRI
PRIMARY POWER
Positive primary transformer power terminal
E1
-VPRI
PRIMARY POWER
RETURN
Negative primary transformer power terminal
A’2, C’2
+VSEC
SECONDARY
POWER
Positive secondary transformer power terminal
B’2, D’2
-VSEC
SECONDARY
POWER RETURN
Negative secondary transformer power terminal
Analog Control Signal Pins
Pin Number
Signal Name
Type
Function
B1
TM
OUTPUT
C1
EN
INPUT
D1
VAUX
OUTPUT
Temperature Monitor; primary side referenced signals
Enables and disables power supply; primary side referenced signals
Auxilary Voltage Source; primary side referenced signals
PMBus Control Signal Pins
Pin Number
Signal Name
Type
B1
SER-OUT
OUTPUT
C1
EN
INPUT
Enables and disables power supply; Primary side referenced signals
D1
SER-IN
INPUT
UART receive pin; Primary side referenced signals
BCM® Bus Converter
Page 4 of 30
Function
UART transmit pin; Primary side referenced signals
Rev 1.3
09/2017
BCM6123xD1E5126yzz
Part Ordering Information
Product
Function
Package
Size
Package
Mounting
Max Primary
Input Voltage
Range
Identifier
Max
Secondary
Voltage
Secondary
Output
Current
Temperature
Grade
Option
BCM
6123
x
D1
E
51
26
y
zz
61 = L
23 = W
T = TH
00 = Analog Ctrl
Bus Converter
Module
S = SMT
410V
260 – 410V
51.3V
No Load
25.7A
T = -40°C – 125°C
01 = PMBus Ctrl
M = -55°C – ­125°C
0R = Reversible Analog Ctrl
0P = Reversible PMBus Ctrl
All products shipped in JEDEC standard high profile (0.400” thick) trays (JEDEC Publication 95, Design Guide 4.10).
Standard Models
Product
Function
Package
Size
Package
Mounting
Max Primary
Input Voltage
Range
Identifier
Max
Secondary
Voltage
Secondary
Output
Current
Temperature
Grade
Option
BCM
6123
T
D1
E
51
26
T
00
BCM
6123
T
D1
E
51
26
T
01
BCM
6123
T
D1
E
51
26
T
0R
BCM
6123
T
D1
E
51
26
T
0P
Absolute Maximum Ratings
The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device.
Parameter
Comments
+VPRI_DC to –VPRI_DC
Min
Max
Unit
-1
480
V
1
V/µs
60
V
4.6
V
5.5
V
4.6
V
VPRI_DC or VSEC_DC Slew Rate
(operational)
+VSEC_DC to –VSEC_DC
-1
TM/SER-OUT to –VPRI_DC
EN to –VPRI_DC
-0.3
VAUX/SER-IN to –VPRI_DC
BCM® Bus Converter
Page 5 of 30
Rev 1.3
09/2017
BCM6123xD1E5126yzz
Electrical Specifications
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade). All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
410
V
120
V
General Powertrain PRIMARY to SECONDARY Specification (Forward Direction)
Primary Input Voltage range,
continuous
VPRI µController
PRI to SEC Input Quiescent Current
260
VPRI_DC
VµC_ACTIVE
IPRI_Q
VPRI_DC voltage where µC is initialized,
(ie VAUX = Low, powertrain inactive)
Disabled, EN Low, VPRI_DC = 380V
2
TINTERNAL ≤ 100ºC
4
VPRI_DC = 380V, TINTERNAL = 25ºC
PRI to SEC No Load Power
Dissipation
PRI to SEC Inrush Current Peak
PPRI_NL
IPRI_INR_PK
9.8
5.9
VPRI_DC = 380V
16
15
VPRI_DC = 260V to 410V
20
4
TINTERNAL ≤ 100ºC
DC Primary Input Current
Transformation Ratio
Secondary Output Current
(continuous)
Secondary Output Current (pulsed)
IPRI_IN_DC
K
Secondary Output Power
(continuous)
PSEC_OUT_DC
Secondary Output Power
(pulsed)
PSEC_OUT_PULSE
A
At ISEC_OUT_DC = 25.7A, TINTERNAL ≤ 100ºC
3.5
Primary to secondary, K = VSEC_DC / VPRI_DC, at no load
1/8
25.7
A
10ms pulse, 25% Duty cycle, ISEC_OUT_AVG ≤ 50% rated
ISEC_OUT_DC
32.2
A
Specified at VPRI_DC = 410V
1200
W
Specified at VPRI_DC = 410V; 10ms pulse, 25% Duty
cycle, PSEC_AVG ≤ 50% rated PSEC_OUT_DC
1500
W
VPRI_DC = 380V, ISEC_OUT_DC = 25.7A
97.1
VPRI_DC = 260V to 410V, ISEC_OUT_DC = 25.7A
96.4
97.6
ηAMB
VPRI_DC = 380V, ISEC_OUT_DC = 12.85A
97.2
97.7
PRI to SEC Efficiency (hot)
ηHOT
VPRI_DC = 380V, ISEC_OUT_DC = 25.7A
96.5
97
PRI to SEC Efficiency
(over load range)
η20%
5.14A < ISEC_OUT_DC < 25.7A
92
RSEC_COLD
VPRI_DC = 380V, ISEC_OUT_DC = 25.7A, TINTERNAL = -40°C
13
16.7
23
RSEC_AMB
VPRI_DC = 380V, ISEC_OUT_DC = 25.7A
21
24.2
31
RSEC_HOT
VPRI_DC = 380V, ISEC_OUT_DC = 25.7A, TINTERNAL = 100°C
30
35
40
Frequency of the Output Voltage Ripple = 2x FSW
1.12
1.18
1.23
Switching Frequency
Secondary Output Voltage Ripple
FSW
VSEC_OUT_PP
CSEC_EXT = 0μF, ISEC_OUT_DC = 25.7A, VPRI_DC = 380V,
20MHz BW
%
Secondary Output Leads Inductance
(Parasitic)
Primary Input Series Inductance
(Internal)
BCM® Bus Converter
Page 6 of 30
%
%
195
TINTERNAL ≤ 100ºC
Primary Input Leads Inductance
(Parasitic)
A
V/V
PRI to SEC Efficiency (ambient)
PRI to SEC Output Resistance
W
10
ISEC_OUT_DC
ISEC_OUT_PULSE
12
VPRI_DC = 260V to 410V, TINTERNAL = 25ºC
VPRI_DC = 410V, CSEC_EXT = 100μF, RLOAD_SEC = 50% of
full load current
mA
mΩ
MHz
mV
300
LPRI_IN_LEADS
Frequency 2.5MHz (double switching frequency),
Simulated lead model
6.7
nH
LSEC_OUT_LEADS
Frequency 2.5MHz (double switching frequency),
Simulated lead model
1.3
nH
Reduces the need for input decoupling inductance in
BCM arrays
0.56
µH
LIN_INT
Rev 1.3
09/2017
BCM6123xD1E5126yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade). All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
General Powertrain PRIMARY to SECONDARY Specification (Forward Direction) Cont.
Effective Primary Capacitance
(Internal)
CPRI_INT
Effective Value at 380VPRI_DC
0.37
µF
Effective Secondary Capacitance
(Internal)
CSEC_INT
Effective Value at 47.5VSEC_DC
25.6
µF
Effective Secondary Output
Capacitance (External)
CSEC_OUT_EXT
Excessive capacitance may drive module into SC
protection
Effective Secondary Output
Capacitance (External)
CSEC_OUT_AEXT
CSEC_OUT_AEXT Max = N * 0.5 * CSEC_OUT_EXT MAX, where
N = the number of units in parallel
100
µF
357.5
ms
Powertrain Protection PRIMARY to SECONDARY (Forward Direction)
Auto Restart Time
tAUTO_RESTART
Startup into a persistent fault condition. Non-Latching
fault detection given VPRI_DC > VPRI_UVLO+
292.5
Primary Overvoltage Lockout
Threshold
VPRI_OVLO+
420
434.5
450
V
Primary Overvoltage Recovery
Threshold
VPRI_OVLO-
405
424
440
V
Primary Overvoltage Lockout
Hysteresis
VPRI_OVLO_HYST
10.5
V
Primary Overvoltage Lockout
Response Time
tPRI_OVLO
100
µs
1
ms
Primary Soft-Start Time
tPRI_SOFT-START
Secondary Output Overcurrent Trip
Threshold
ISEC_OUT_OCP
Secondary Output Overcurrent
Response Time Constant
tSEC_OUT_OCP
Secondary Output Short Circuit
Protection Trip Threshold
ISEC_OUT_SCP
Secondary Output Short Circuit
Protection Response Time
tSEC_OUT_SCP
Overtemperature Shutdown
Threshold
BCM® Bus Converter
Page 7 of 30
tOTP+
From powertrain active. Fast Current limit protection
disabled during Soft-Start
28
Effective internal RC filter
37
3.2
45
Rev 1.3
09/2017
125
A
ms
A
1
Temperature sensor located inside controller IC
50
µs
°C
BCM6123xD1E5126yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Powertrain Supervisory Limits PRIMARY to SECONDARY (Forward Direction)
Primary Overvoltage Lockout
Threshold
VPRI_OVLO+
420
434.5
450
V
Primary Overvoltage Recovery
Threshold
VPRI_OVLO-
405
424
440
V
Primary Overvoltage Lockout
Hysteresis
VPRI_OVLO_HYST
10.5
V
Primary Overvoltage Lockout
Response Time
tPRI_OVLO
100
µs
Primary Undervoltage Lockout
Threshold
VPRI_UVLO-
220
235
250
V
Primary Undervoltage Recovery
Threshold
VPRI_UVLO+
230
245
260
V
Primary Undervoltage Lockout
Hysteresis
VPRI_UVLO_HYST
10
V
Primary Undervoltage Lockout
Response Time
tPRI_UVLO
100
µs
20
ms
Primary Undervoltage Startup Delay
From VPRI_DC = VPRI_UVLO+ to powertrain active, EN
tPRI_UVLO+_DELAY floating, (i.e One time Startup delay from application
of VPRI_DC to VSEC_DC)
Secondary Output Overcurrent Trip
Threshold
ISEC_OUT_OCP
Secondary Output Overcurrent
Response Time Constant
tSEC_OUT_OCP
Overtemperature Shutdown
Threshold
tOTP+
Overtemperature Recovery
Threshold
tOTP–
Undertemperature Shutdown
Threshold
tUTP
Undertemperature Restart Time
BCM® Bus Converter
Page 8 of 30
tUTP_RESTART
28
Effective internal RC filter
Temperature sensor located inside controller IC
37
3.2
°C
110
Temperature sensor located inside controller IC;
Protection not available for M-Grade units.
Rev 1.3
09/2017
A
ms
125
105
Startup into a persistent fault condition. Non-Latching
fault detection given VPRI_DC > VPRI_UVLO+
50
3
115
°C
-45
°C
s
BCM6123xD1E5126yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
51.25
V
General Powertrain SECONDARY to PRIMARY Specification (Reverse Direction)
Secondary Input Voltage range,
continuous
32.5
VSEC_DC
VSEC_DC = 47.5V, TINTERNAL = 25ºC
SEC to PRI No Load Power
Dissipation
DC Secondary Input Current
Primary Output Power (continuous)
Primary Output Power (pulsed)
Primary Output Current (continuous)
Primary Output Current (pulsed)
PSEC_NL
ISEC_IN_DC
PPRI_OUT_DC
PPRI_OUT_PULSE
9
5.9
VSEC_DC = 47.5V
16
VSEC_DC = 32.5V to 51.25V, TINTERNAL = 25ºC
15
VSEC_DC = 32.5V to 51.25V
20
At IPRI_DC = 3.2A, TINTERNAL ≤ 100ºC
26
A
1200
W
Specified at VSEC_DC = 51.25V; 10ms pulse,
25% Duty cycle, PPRI_AVG ≤ 50 rated PPRI_OUT_DC
1500
W
3.2
A
4
A
10ms pulse, 25% Duty cycle,
IPRI_OUT_AVG ≤ 50% rated IPRI_OUT_DC
VSEC_DC = 47.5V, IPRI_OUT_DC = 3.2A
97.1
VSEC_DC = 32.5V to 51.25V, IPRI_OUT_DC= 3.2A
96.4
97.6
SEC to PRI Efficiency (ambient)
ηAMB
VSEC_DC = 47.5V, IPRI_OUT_DC = 1.6A
97.2
97.7
SEC to PRI Efficiency (hot)
ηHOT
VSEC_DC = 47.5V, IPRI_OUT_DC = 3.2A
96.5
97
SEC to PRI Efficiency
(over load range)
η20%
0.64A < IPRI_OUT_DC < 3.2A
SEC to PRI Output Resistance
Primary Output Voltage Ripple
BCM® Bus Converter
Page 9 of 30
%
%
92
%
RPRI_COLD
VSEC_DC = 47.5V, IPRI_OUT_DC = 3.2A, TINTERNAL = -40°C
1500
1698
1950
RPRI_AMB
VSEC_DC = 47.5V, IPRI_OUT_DC = 3.2A
1950
2241
2400
RPRI_HOT
VSEC_DC = 47.5V, IPRI_OUT_DC = 3.2A, TINTERNAL = 100°C
2700
2862
3200
VPRI_OUT_PP
W
Specified at VSEC_DC = 51.25V
IPRI_OUT_DC
IPRI_OUT_PULSE
12
CPRI_OUT_EXT = 0μF, IPRI_OUT_DC = 3.2A,
VSEC_DC = 47.5V, 20MHz BW
TINTERNAL ≤ 100ºC
1600
mV
2400
Rev 1.3
09/2017
mΩ
BCM6123xD1E5126yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
52.5
54.5
56.5
V
Protection SECONDARY to PRIMARY (Reverse Direction)
Secondary Overvoltage Lockout
Threshold
VSEC_OVLO+
Secondary Overvoltage Lockout
Response Time
tPRI_OVLO
Secondary Undervoltage Lockout
Threshold
VSEC_UVLO-
Secondary Undervoltage Lockout
Response Time
tSEC_UVLO
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
100
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
14
15
µs
16
100
V
µs
Primary Undervoltage Lockout
Threshold
VPRI_UVLO-_R
Applies only to reversilbe products in forward and in
reverse direction; IPRI_DC ≤ 20% while VPRI_UVLO-_R
< VPRI_DC < VPRI_MIN
110
120
130
V
Primary Undervoltage Recovery
Threshold
VPRI_UVLO+_R
Applies only to reversilbe products in forward and in
reverse direction
120
130
150
V
Primary Undervoltage Lockout
Hysteresis
VPRI_UVLO_HYST_R
Applies only to reversilbe products in forward and in
reverse direction
Primary Output Overcurrent Trip
Threshold
IPRI_OUT_OCP
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
Primary Output Overcurrent
Response Time Constant
tPRI_OUT_OCP
Effective internal RC filter
Primary Short Circuit Protection Trip
Threshold
IPRI_SCP
Primary Short Circuit Protection
Response Time
tPRI_SCP
BCM® Bus Converter
Page 10 of 30
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
10
3.5
4
3.6
5.6
6
A
ms
A
1
Rev 1.3
09/2017
V
µs
BCM6123xD1E5126yzz
Primary/Secondary
Output Power (W)
1400
1200
1000
800
600
400
200
0
35
45
55
65
75
85
95
105
115
125
Case Temperature (°C)
Top only at temperature
Top and leads at temperature
Top, leads, and belly at temperature
1600
Secondary Output Current (A)
Secondary Output Power (W)
Figure 1 — Specified thermal operating area
1500
1400
1300
1200
1100
1000
900
800
700
260
275
290
305
320
335
350
365
380
395
410
34
32
30
28
26
24
22
20
18
16
260
275
290
305
335
350
365
Primary Input Voltage (V)
PSEC_OUT_DC
ISEC_OUT_DC
PSEC_OUT_PULSE
Secondary Output Capacitance
(% Rated CSEC_EXT_MAX)
Figure 2 — Specified electrical operating area using rated RSEC_HOT
110
100
90
80
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100 110
Secondary Output Current (% ISEC_OUT_DC)
Figure 3 — Specified Primary start-up into load current and external capacitance
BCM® Bus Converter
Page 11 of 30
320
Primary Input Voltage (V)
Rev 1.3
09/2017
380
395
ISEC_OUT_PULSE
410
BCM6123xD1E5126yzz
Analog Control Signal Characteristics
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Temperature Monitor
• The TM pin is a standard analog I/O configured as an output from an internal µC.
• The TM pin monitors the internal temperature of the controller IC within an accuracy of ±5°C.
• µC 250kHz PWM output internally pulled high to 3.3V.
SIGNAL TYPE
STATE
Startup
ATTRIBUTE
Powertrain active to TM
time
TM Duty Cycle
TM Current
SYMBOL
CONDITIONS / NOTES
MIN
TYP
MAX
100
tTM
18.18
TMPWM
ITM
UNIT
µs
68.18
%
4
mA
Recommended External filtering
DIGITAL
OUTPUT
Regular
Operation
TM Capacitance (External)
CTM_EXT
Recommended External filtering
0.01
µF
TM Resistance (External)
RTM_EXT
Recommended External filtering
1
kΩ
ATM
10
mV / °C
VTM_AMB
1.27
V
Specifications using recommended filter
TM Gain
TM Voltage Reference
TM Voltage Ripple
VTM_PP
RTM_EXT = 1kΩ, CTM_EXT = 0.01µF,
VPRI_DC = 380V, ISEC_DC = 25.7A
28
TINTERNAL ≤ 100ºC
mV
40
Enable / Disable Control
•
•
•
•
The EN pin is a standard analog I/O configured as an input to an internal µC.
It is internally pulled high to 3.3V.
When held low the BCM internal bias will be disabled and the powertrain will be inactive.
In an array of BCMs, EN pins should be interconnected to synchronize startup.
SIGNAL TYPE
STATE
Startup
ANALOG
INPUT
Regular
Operation
ATTRIBUTE
EN to Powertrain
active time
tEN_START
CONDITIONS / NOTES
MIN
VPRI_DC > VPRI_UVLO+, EN held low both
conditions satisfied for T > tPRI_UVLO+_DELAY
TYP
MAX
250
VEN_TH
EN Resistance (Internal)
REN_INT
Internal pull up resistor
VEN_DISABLE_TH
Rev 1.3
09/2017
UNIT
µs
2.3
EN Voltage Threshold
EN Disable Threshold
BCM® Bus Converter
Page 12 of 30
SYMBOL
V
1.5
kΩ
1
V
BCM6123xD1E5126yzz
Analog Control Signal Characteristics (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Auxiliary Voltage Source
• The VAUX pin is a standard analog I/O configured as an output from an internal µC.
• VAUX is internally connected to µC output as internally pulled high to a 3.3V regulator with 2% tolerance, a 1% resistor of 1.5kΩ.
• VAUX can be used as a “Ready to process full power” flag. This pin transitions VAUX voltage after a 2ms delay from the start of powertrain activating,
signaling the end of softstart.
• VAUX can be used as “Fault flag”. This pin is pulled low internally when a fault protection is detected.
SIGNAL TYPE
STATE
Startup
ANALOG
OUTPUT
Regular
Operation
Fault
BCM® Bus Converter
Page 13 of 30
ATTRIBUTE
SYMBOL
Powertrain ­active to
VAUX time
tVAUX
VAUX Voltage
VVAUX
VAUX Available Current
IVAUX
CONDITIONS / NOTES
MIN
TYP
2
Powertrain active to VAUX High
2.8
VAUX Voltage Ripple
VVAUX_PP
VAUX Capacitance
(External)
CVAUX_EXT
VAUX Resistance (External)
RVAUX_EXT
VAUX Fault Response Time
tVAUX_FR
MAX
ms
3.3
V
4
mA
50
TINTERNAL ≤ 100ºC
100
0.01
VPRI_DC < VµC_ACTIVE
From fault to VVAUX = 2.8V, CVAUX = 0pF
Rev 1.3
09/2017
1.5
UNIT
mV
µF
kΩ
10
µs
BCM6123xD1E5126yzz
PMBus™ Control Signal Characteristics
Specifications apply over all line, load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
UART SER-IN / SER-OUT Pins
• Universal Asynchronous Receiver/Transmitter (UART) pins.
• The BCM communication version is not intended to be used without a Digital Supervisor.
• Isolated I2C communication and telemetry is available when using Vicor Digital Isolator and Vicor Digital Supervisor. Please see specific product data sheet
for more details.
• UART SER-IN pin is internally pulled high using a 1.5kΩ to 3.3V.
SIGNAL TYPE
STATE
GENERAL I/O
ATTRIBUTE
SYMBOL
Baud Rate
BRUART
CONDITIONS / NOTES
MIN
TYP
MAX
750
Rate
UNIT
Kbit/s
SER-IN Pin
SER-IN Input Voltage Range
VSER-IN_IH
2.3
V
VSER-IN_IL
DIGITAL
INPUT
Regular
Operation
V
SER-IN rise time
tSER-IN_RISE
10% to 90%
400
ns
SER-IN fall time
tSER-IN_FALL
10% to 90%
25
ns
SER-IN RPULLUP
RSER-IN_PLP
Pull up to 3.3V
1.5
kΩ
SER-IN External Capacitance
CSER-IN_EXT
400
pF
SER-OUT Pin
VSER-OUT_OH
0mA ≥ IOH ≥ -4mA
VSER-OUT_OL
0mA ≤ IOL ≤ 4mA
SER-OUT rise time
tSER-OUT_RISE
10% to 90%
55
ns
SER-OUT fall time
tSER-OUT_FALL
10% to 90%
45
ns
SER-OUT Output Voltage
Range
DIGITAL
OUTPUT
1
SER-OUT source current
ISER-OUT
SER-OUT output impedance
ZSER-OUT
2.8
V
0.5
VSER-OUT = 2.8V
6
V
mA
Ω
120
Enable / Disable Control
•
•
•
•
•
The EN pin is a standard analog I/O configured as an input to an internal µC.
It is internally pulled high to 3.3V.
When held low the BCM internal bias will be disabled and the powertrain will be inactive.
In an array of BCMs, EN pins should be interconnected to synchronize startup.
Enable / disable command will have no effect if the EN pin is disabled.
SIGNAL TYPE
ANALOG
INPUT
STATE
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
Startup
EN to Powertrain active time
tEN_START
VPRI_DC > VPRI_UVLO+,
EN held low both conditions satisfied
for t > tPRI_UVLO+_DELAY­­
EN Voltage Threshold
VENABLE
EN Resistance (Internal)
REN_INT
Regular
Operation
EN Disable Threshold
BCM® Bus Converter
Page 14 of 30
VEN_DISABLE_TH
Rev 1.3
09/2017
MIN
TYP
MAX
250
µs
2.3
Internal pull up resistor
UNIT
V
1.5
kΩ
1
V
BCM6123xD1E5126yzz
PMBus™ Reported Characteristics
Specifications apply over all line, load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Monitored Telemetry
• The BCM communication version is not intended to be used without a Digital Supervisor.
DIGITAL SUPERVISOR
PMBusTM READ COMMAND
ACCURACY
(RATED RANGE)
FUNCTIONAL
REPORTING RANGE
UPDATE
RATE
REPORTED UNITS
Input voltage
(88h) READ_VIN
± 5% (LL - HL)
130V to 450V
100µs
VACTUAL = VREPORTED x 10-1
Input current
(89h) READ_IIN
± 20% (10 - 20% of FL)
± 5% (20 - 133% of FL)
-4.6A to 4.6A
100µs
IACTUAL = IREPORTED x 10-3
Output voltage [1]
(8Bh) READ_VOUT
± 5% (LL - HL)
16.25V to 56.25V
100µs
VACTUAL = VREPORTED x 10-1
Output current
(8Ch) READ_IOUT
± 20% (10 - 20% of FL)
± 5% (20 - 133% of FL)
-37A to 37A
100µs
IACTUAL = IREPORTED x 10-2
Output resistance
(D4h) READ_ROUT
± 5% (50 - 100% of FL) at NL
± 10% (50 - 100% of FL) (LL - HL)
10mΩ to 40mΩ
100ms
RACTUAL = RREPORTED x 10-5
(8Dh) READ_TEMPERATURE_1
± 7°C (Full Range)
- 55ºC to 130ºC
100ms
TACTUAL = TREPORTED
ATTRIBUTE
Temperature [2]
[1]
[2]
Default READ Output Voltage returned when unit is disabled = -300 V.
Default READ Temperature returned when unit is disabled = -273°C.
Variable Parameter
• Factory setting of all below Thresholds and Warning limits are 100% of listed protection values.
• Variables can be written only when module is disabled either EN pulled low or VIN < VIN_UVLO-.
• Module must remain in a disabled mode for 3ms after any changes to the below variables allowing ample time to commit changes to EEPROM.
ATTRIBUTE
DIGITAL SUPERVISOR
PMBusTM COMMAND [3]
CONDITIONS / NOTES
Input / Output Overvoltage
Protection Limit
(55h) VIN_OV_FAULT_LIMIT
VIN_OVLO- is automatically 3%
lower than this set point
Input / Output Overvoltage
Warning Limit
(57h) VIN_OV_WARN_LIMIT
Input / Output Undervoltage
Protection Limit
(D7h) DISABLE_FAULTS
Can only be disabled to a preset
default value
ACCURACY
(RATED RANGE)
FUNCTIONAL
REPORTING
RANGE
DEFAULT
VALUE
± 5% (LL - HL)
130V to 435V
100%
± 5% (LL - HL)
130V to 435V
100%
± 5% (LL - HL)
130V or 260V
100%
Input Overcurrent Protection Limit
(5Bh) IIN_OC_FAULT_LIMIT
± 20% (10 - 20% of FL)
± 5% (20 - 133% of FL)
0 to 4.375A
100%
Input Overcurrent
Warning Limit
(5Dh) IIN_OC_WARN_LIMIT
± 20% (10 - 20% of FL)
± 5% (20 - 133% of FL)
0 to 4.375A
100%
Overtemperature Protection
Limit
(4Fh) OT_FAULT_LIMIT
± 7°C (Full Range)
0 to 125°C
100%
Overtemperature
Warning Limit
(51h) OT_WARN_LIMIT
± 7°C (Full Range)
0 to 125°C
100%
± 50µs
0 to 100ms
0ms
Turn on Delay
[3]
(60h) TON_DELAY
Additional time delay to the
Undervoltage Startup Delay
Refer to Digital Supervisor datasheet for complete list of supported commands.
BCM® Bus Converter
Page 15 of 30
Rev 1.3
09/2017
BCM® Bus Converter
Page 16 of 30
Rev 1.3
09/2017
VAUX
TM
OUTPUT
OUTPUT
OUTPUT
EN
+VPRI
+VSEC
BIDIR
INPUT
STARTUP
tVAUX
tPRI_UVLO+_DELAY
VPRI_UVLO+
VµC_ACTIVE
VPRI_OVLO+
VNOM
OVER VOLTAGE
VPRI_UVLO-
VPRI_OVLO-
up
ll u
N
O P
ER
T
N- AL
PU
OV
R
N
T
U
TU TER
UT
E YO N
NP G E
U T IN
Z
I
I
R
P
O
L
Y TA
IN U X
IA NDA RN
A R OL
T
A
C
I
D
V
_
IN CO TU RIM V
RI
P
VP N &
µc SE
E
tAUTO-RESTART
ENABLE CONTROL
OVER CURRENT
>
tPRI_UVLO+_DELAY
tSEC_OUT_SCP
SHUTDOWN
GE
NT
TA
H
L
E
W G
EV
VO
LO HI
S
T F
IT
D
D
RE
U
U
F
P
LE LE
T
RC
IN N-O
UL PUL
PU
CI
Y
P
R
N
T
R
I
R
A TU
LE LE
C
_D
IM
AB AB
HO
RI
R
S
N
P
N
P
V
E
E
RT
TA
BCM6123xD1E5126yzz
BCM Module Timing Diagram
BCM6123xD1E5126yzz
High Level Functional State Diagram
Application
of input voltage to VPRI_DC
VµC_ACTIVE < VPRI_DC < VPRI_UVLO+
STANDBY SEQUENCE
VPRI_DC > VPRI_UVLO+
STARTUP SEQUENCE
TM Low
TM Low
EN High
EN High
VAUX Low
VAUX Low
Powertrain Stopped
Powertrain Stopped
ENABLE falling edge,
or OTP detected
Fault
Autorecovery
FAULT
SEQUENCE
TM Low
EN High
VAUX Low
Input OVLO or UVLO,
Output OCP,
or UTP detected
ENABLE falling edge,
or OTP detected
Input OVLO or UVLO,
Output OCP,
or UTP detected
Powertrain Stopped
Short Circuit detected
BCM® Bus Converter
Page 17 of 30
tPRI_UVLO+_DELAY
expired
ONE TIME DELAY
INITIAL STARTUP
Rev 1.3
09/2017
SUSTAINED
OPERATION
TM PWM
EN High
VAUX High
Powertrain Active
BCM6123xD1E5126yzz
Application Characteristics
PRI to SEC, Full Load Efficiency (%)
PRI to SEC, Power Dissipation (W)
Product is mounted and temperature controlled via top side cold plate, unless otherwise noted. All data presented in this section are collected data from
primary sourced units processing power in forward direction.See associated figures for general trend data.
14
13
12
11
10
9
8
7
6
5
4
3
260
275
290
305
320
335
350
365
380
395
410
98.0
97.8
97.5
97.3
97.0
96.8
96.5
96.3
96.0
-40
-20
0
Primary Input Voltage (V)
-40°C
80°C
Figure 4 — No load power dissipation vs. VPRI_DC
VPRI:
PRI to SEC, Efficiency (%)
98
96
94
92
90
0.0
2.6
5.1
7.7
10.3 12.9 15.4 18.0 20.6 23.1 25.7
380V
Figure 6 — Efficiency at TCASE = -40°C
PRI to SEC, Efficiency (%)
94
92
90
5.1
7.7
10.3 12.9 15.4 18.0 20.6 23.1 25.7
Secondary Output Current (A)
VPRI:
260V
Figure 8 — Efficiency at TCASE = 25°C
BCM® Bus Converter
Page 18 of 30
410V
32
24
16
8
0
0.0
2.6
5.1
7.7
10.3 12.9 15.4 18.0 20.6 23.1 25.7
260V
380V
410V
Figure 7 — Power dissipation at TCASE = -40°C
96
2.6
380V
Secondary Output Current (A)
98
0.0
260V
VPRI:
100
88
100
40
410V
PRI to SEC, Power Dissipation
260V
80
48
Secondary Output Current (A)
VPRI:
60
Figure 5 — Full load efficiency vs. temperature; VPRI_DC
100
88
40
Case Temperature (ºC)
25°C
PRI to SEC, Power Dissipation
TTOP SURFACE CASE:
20
380V
48
40
32
24
16
8
0
0.0
2.6
5.1
7.7
10.3 12.9 15.4 18.0 20.6 23.1 25.7
Secondary Output Current (A)
410V
VPRI:
260V
380V
Figure 9 — Power dissipation at TCASE = 25°C
Rev 1.3
09/2017
410V
PRI to SEC, Power Dissipation
BCM6123xD1E5126yzz
PRI to SEC, Efficiency (%)
100
98
96
94
92
90
88
0.0
2.6
5.1
7.7
10.3 12.9 15.4 18.0 20.6 23.1 25.7
48
40
32
24
16
8
0
0.0
2.6
5.1
Secondary Output Current (A)
VPRI:
260V
380V
VPRI:
Secondary Output Voltage Ripple (mV)
PRI to SEC, Output Resistance (mΩ)
40
30
20
10
0
0
20
40
60
80
100
Case Temperature (°C)
VSEC_DC:
380V
410V
100
90
80
70
60
50
40
30
20
10
0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
Secondary Output Current (A)
VPRI:
25.7A
Figure 12 — RSEC vs. temperature; Nominal VPRI_DC
ISEC_DC = 19.5A at TCASE = 80°C
380V
Figure 13 — VSEC_OUT_PP vs. ISEC_DC ; No external CSEC_OUT_EXT. Board
mounted module, scope setting:
20MHz analog BW
Figure 14 — Full load ripple, 270µF CPRI_IN_EXT; No external
CSEC_OUT_EXT. Board mounted module, scope setting:
20MHz analog BW
BCM® Bus Converter
Page 19 of 30
260V
Figure 11 — Power dissipation at TCASE = 80°C
50
-20
10.3 12.9 15.4 18.0 20.6 23.1 25.7
Secondary Output Current (A)
410V
Figure 10 — Efficiency at TCASE = 80°C
-40
7.7
Rev 1.3
09/2017
BCM6123xD1E5126yzz
Figure 15 — 0A – 25.7A transient response:
CPRI_IN_EXT = 270µF, no external CSEC_OUT_EXT
Figure 16 — 25.7A – 0A transient response:
CPRI_IN_EXT = 270µF, no external CSEC_OUT_EXT
Figure 17 — Start up from application of VPRI_DC = 380V,
50% ISEC_DC, 100% CSEC_OUT_EXT
Figure 18 — Start up from application of EN with pre-applied
VPRI_DC = 380V, 50% ISEC_DC, 100% CSEC_OUT_EXT
BCM® Bus Converter
Page 20 of 30
Rev 1.3
09/2017
BCM6123xD1E5126yzz
General Characteristics
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Mechanical
Length
L
62.96 / [2.479] 63.34 / [2.494] 63.72 / [2.509]
mm/[in]
Width
W
22.67 / [0.893] 22.80 / [0.898] 22.93 / [0.903]
mm/[in]
Height
H
7.11 / [0.280]
mm/[in]
Volume
Vol
Weight
W
Lead finish
Without Heatsink
7.21 / [0.284]
7.31 / [0.288]
cm3/[in3]
10.41 / [0.636]
41 / [1.45]
g/[oz]
Nickel
0.51
2.03
Palladium
0.02
0.15
Gold
0.003
0.051
BCM6123xD1E5126yzz (T-Grade)
-40
125
°C
BCM6123xD1E5126yzz (M-Grade)
-55
125
°C
µm
Thermal
Operating Temperature
Thermal Resistance Top Side
Thermal Resistance Leads
Thermal Resistance Bottom Side
TINTERNAL
θINT-TOP
θINT-LEADS
θINT-BOTTOM
Estimated thermal resistance to maximum
temperature internal component from
isothermal top
1.28
°C/W
Estimated thermal resistance to
maximum temperature internal
component from isothermal leads
7.9
°C/W
Estimated thermal resistance to
maximum temperature internal
component from isothermal bottom
1.28
°C/W
34
Ws/°C
Thermal Capacity
Assembly
BCM6123xD1E5126yzz (T-Grade)
-55
125
°C
BCM6123xD1E5126yzz (M-Grade)
-65
125
°C
Storage temperature
ESD Withstand
BCM® Bus Converter
Page 21 of 30
ESDHBM
Human Body Model, “ESDA / JEDEC JDS-001-2012” Class I-C (1kV to < 2kV)
ESDCDM
Charge Device Model, “JESD 22-C101-E” Class II (200V to < 500V)
Rev 1.3
09/2017
BCM6123xD1E5126yzz
General Characteristics (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
135
°C
Soldering [1]
Peak Temperature Top Case
Safety
Isolation voltage / Dielectric test
VHIPOT
PRIMARY to SECONDARY
4,242
PRIMARY to CASE
2,121
SECONDARY to CASE
2,121
Isolation Capacitance
CPRI_SEC
Unpowered Unit
620
Insulation Resistance
RPRI_SEC
At 500VDC
10
MTBF
VDC
780
MIL-HDBK-217Plus Parts Count - 25°C
Ground Benign, Stationary, Indoors /
Computer
3.53
MHrs
Telcordia Issue 2 - Method I Case III; 25°C
Ground Benign, Controlled
3.90
MHrs
cURus UL 60950-1
CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable
Previous Part Numbers
BCM380x475y1K2A3z
BCM380x475y1K2A31
[1]
Product is not intended for reflow solder attach.
BCM® Bus Converter
Page 22 of 30
pF
MΩ
cTUVus EN 60950-1
Agency Approvals / Standards
940
Rev 1.3
09/2017
BCM6123xD1E5126yzz
PMBus™ System Diagram
-OUT
BCM
SER-OUT
-IN BCM
SEC-IN-B
PRI-OUT-B
PRI-IN-C
SEC-OUT-C
PRI-COM
RXD1
RXD4
VDDB
RXD3
VDD
RXD2
SEC-COM
NC
D44TL1A0
RXD1
VDD
5V EXT
TXD4
NC
NC
TXD3
SSTOP
3 kΩ
SDA
TX D 1 ’
NC
SEC-IN-A
PRI-OUT-A
SDA
NC
SER-IN
SCL
BCM EN
NC
Digital Isolator
SGND
SCL
3 kΩ
VDD
CP
D
Q
SGND
VCC
D
Flip-flop
NC
SADDR
NC
NC
TXD1
TXD2
74LVC1G74DC
10 kΩ
FDG6318P
R2
10 kΩ
EN Control
3.3V, at least 20mA
when using 4xDISO
Ref to Digital Isolator
datasheet for more details
SD
RD
Q
SDA
SCL
Host
µc
PMBus
R1
SGND
The PMBus communication enabled bus converter provides accurate telemetry monitoring and reporting, threshold and warning
limits adjustment, in addition to corresponding status flags.
The BCM internal µC is referenced to primary ground. The Digital Isolator allows UART communication interface with the host Digital
Supervisor at typical speed of 750KHz across the isolation barrier. One of the advantages of the Digital Isolator is its low power
consumption. Each transmission channel is able to draw its internal bias circuitry directly from the input signal being transmitted to
the output with minimal to no signal distortion.
The Digital Supervisor provides the host system µC with access to an array of up to 4 BCMs. This array is constantly polled for status
by the Digital Supervisor. Direct communication to individual BCM is enabled by a page command. For example, the page (0x00)
prior to a telemetry inquiry points to the Digital Supervisor data and pages (0x01 – 0x04) prior to a telemetry inquiry points to the
array of BCMs connected data. The Digital Supervisor constantly polls the BCM data through the UART interface.
The Digital Supervisor enables the PMBus compatible host interface with an operating bus speed of up to 400kHz. The Digital
Supervisor follows the PMBus command structure and specification.
Please refer to the Digital Supervisor data sheet for more details.
BCM® Bus Converter
Page 23 of 30
Rev 1.3
09/2017
BCM6123xD1E5126yzz
Sine Amplitude Converter™ Point of Load Conversion
RSEC
1.77nH
LPRI_IN_LEADS = 6.7nH
+
CPRI_INT_ESR
21.5mΩ
CPRI_INT C
IN
0.37µF
VVPRIIN
–
24.2mΩ
I ISEC
RCIN
+
+
IPRI_Q
IQ
25.8mA
–
K
LPRI_INT = 1.20µH
RCCSEC_INT_ESR
OUT
139mΩ
V•I
1/8 • ISEC
LSEC_OUT_LEADS = 1.3nH
ROUT
OUT
+
510µΩ
1/8 • VPRI
CSEC_INT
COUT
25.6µF
–
VSEC
VOUT
–
Figure 19 — BCM module AC model
The Sine Amplitude Converter (SAC™) uses a high frequency
resonant tank to move energy from Primary to secondary and
vice versa. The resonant LC tank, operated at high frequency,
is amplitude modulated as a function of primary voltage and
secondary current. A small amount of capacitance embedded in
the primary and secondary stages of the module is sufficient for full
functionality and is key to achieving high power density.
Eq. (3) now becomes Eq. (1) and is essentially load independent,
resistor R is now placed in series with VPRI.
R
The BCM6123xD1E5126yzz SAC can be simplified into the
preceeding model.
Vin
V
PRI
+
–
SAC™
SAC
1/8
KK==1/32
Vout
V
SEC
At no load:
VSEC = VPRI • K
(1)
Figure 20 — K = 1/8 Sine Amplitude Converter
with series primary resistor
K represents the “turns ratio” of the SAC.
Rearranging Eq (1):
K=
VSEC
The relationship between VPRI and VSEC becomes:
VSEC = (VPRI – IPRI • R) • K
(2)
VPRI
Substituting the simplified version of Eq. (4)
(IPRI_Q is assumed = 0A) into Eq. (5) yields:
In the presence of load, VSEC is represented by:
VSEC = VPRI • K – ISEC • RSEC
(3)
VSEC = VPRI • K – ISEC • R • K2
and ISEC is represented by:
ISEC =
IPRI – IPRI_Q
K
(6)
This is similar in form to Eq. (3), where RSEC is used to represent the
characteristic impedance of the SAC™. However, in this case a real
R on the primary side of the SAC is effectively scaled by K 2 with
respect to the secondary.
(4)
RSEC represents the impedance of the SAC, and is a function of
the RDSON of the primary and secondary MOSFETs and the winding
resistance of the power transformer. IPRI_Q represents the quiescent
current of the SAC control, gate drive circuitry, and core losses.
Assuming that R = 1Ω, the effective R as seen from the secondary
side is 16mΩ, with K = 1/8.
The use of DC voltage transformation provides additional
interesting attributes. Assuming that RSEC = 0Ω and IPRI_Q = 0A,
BCM® Bus Converter
Page 24 of 30
(5)
Rev 1.3
09/2017
BCM6123xD1E5126yzz
A similar exercise should be performed with the additon of
a capacitor or shunt impedance at the primary input to the
SAC. A switch in series with VPRI is added to the circuit. This is
depicted in Figure 21.
Low impedance is a key requirement for powering a highcurrent, low-voltage load efficiently. A switching regulation stage
should have minimal impedance while simultaneously providing
appropriate filtering for any switched current. The use of a SAC
between the regulation stage and the point of load provides a
dual benefit of scaling down series impedance leading back to
the source and scaling up shunt capacitance or energy storage
as a function of its K factor squared. However, the benefits are
not useful if the series impedance of the SAC is too high. The
impedance of the SAC must be low, i.e. well beyond the crossover
frequency of the system.
S
VVin
PRI
+
–
SAC™
SAC
K = 1/8
K = 1/32
C
V
SEC
Vout
A solution for keeping the impedance of the SAC low involves
switching at a high frequency. This enables small magnetic
components because magnetizing currents remain low. Small
magnetics mean small path lengths for turns. Use of low loss core
material at high frequencies also reduces core losses.
Figure 21 — Sine Amplitude Converter with primary capacitor
The two main terms of power loss in the BCM module are:
A change in VPRI with the switch closed would result in a change in
capacitor current according to the following equation:
IC (t) = C
dVPRI
(7)
dt
nnNo load power dissipation (PPRI_NL): defined as the power
used to power up the module with an enabled powertrain
at no load.
nnResistive loss (PRSEC): refers to the power loss across
the BCM module modeled as pure resistive impedance.
Assume that with the capacitor charged to VPRI, the switch is
opened and the capacitor is discharged through the idealized
SAC. In this case,
Therefore,
(8)
IC = ISEC • K
PSEC_OUT = PPRI_IN – PDISSIPATED = PPRI_IN – PPRI_NL – PRSEC (11)
substituting Eq. (1) and (8) into Eq. (7) reveals:
ISEC(t) =
C
K2
•
dVSEC
The above relations can be combined to calculate the overall
module efficiency:
(9)
dt
K2
The equation in terms of the output has yielded a
scaling factor
for C, specified in the denominator of the equation.
A K factor less than unity results in an effectively larger capacitance
on the secondary when expressed in terms of the primary. With a
K = 1/8 as shown in Figure 21, C = 1µF would appear as
C = 64µF when viewed from the secondary.
η=
=
PSEC_OUT
PPRI_IN
Rev 1.3
09/2017
=
PPRI_IN – PPRI_NL – PRSEC
PPRI_IN
VPRI • IPRI – PPRI_NL – (ISEC)2 • RSEC
= 1–
BCM® Bus Converter
Page 25 of 30
(10)
PDISSIPATED = PPRI_NL + PRSEC
VPRI • IPRI
(
)
PPRI_NL + (ISEC)2 • RSEC
VPRI • IPRI
(12)
BCM6123xD1E5126yzz
Input and Output Filter Design
Thermal Considerations
A major advantage of SAC™ systems versus conventional PWM
converters is that the transformer based SAC does not require
external filtering to function properly. The resonant LC tank,
operated at extreme high frequency, is amplitude modulated as a
function of primary voltage and secondary current and efficiently
transfers charge through the isolation transformer. A small amount
of capacitance embedded in the primary and secondary stages
of the module is sufficient for full functionality and is key to
achieving power density.
The ChiP package provides a high degree of flexibility in that it
presents three pathways to remove heat from internal power
dissipating components. Heat may be removed from the top
surface, the bottom surface and the leads. The extent to which
these three surfaces are cooled is a key component for determining
the maximum current that is available from a ChiP, as can be
seen from Figure 1.
This paradigm shift requires system design to carefully evaluate
external filters in order to:
nn
Guarantee low source impedance:
To take full advantage of the BCM module’s dynamic response,
the impedance presented to its primary terminals must be low
from DC to approximately 5MHz. The connection of the bus
converter module to its power source should be implemented
with minimal distribution inductance. If the interconnect
inductance exceeds 100nH, the input should be bypassed with a
RC damper to retain low source impedance and stable operation.
With an interconnect inductance of 200nH, the RC damper
may be as high as 1µF in series with 0.3Ω. A single electrolytic
or equivalent low-Q capacitor may be used in place of the
series RC bypass.
Since the ChiP has a maximum internal temperature rating, it is
necessary to estimate this internal temperature based on a real
thermal solution. Given that there are three pathways to remove
heat from the ChiP, it is helpful to simplify the thermal solution into
a roughly equivalent circuit where power dissipation is modeled as
a current source, isothermal surface temperatures are represented
as voltage sources and the thermal resistances are represented as
resistors. Figure 22 shows the “thermal circuit” for a 6123 BCM in
an application where the top, bottom, and leads are cooled. In this
case, the BCM power dissipation is PDTOTAL and the three surface
temperatures are represented as TCASE_TOP,
TCASE_BOTTOM, and TLEADS. This thermal system can now be very
easily analyzed using a SPICE simulator with simple resistors,
voltage sources, and a current source. The results of the simulation
would provide an estimate of heat flow through the various
pathways as well as internal temperature.
nn
Further reduce primary and/or secondary voltage ripple without
sacrificing dynamic response:
Thermal Resistance Top
MAX INTERNAL TEMP
θINT-TOP
Given the wide bandwidth of the module, the source response
is generally the limiting factor in the overall system response.
Anomalies in the response of the primary source will appear at
the secondary of the module multiplied by its K factor.
Thermal Resistance Bottom
Thermal Resistance Leads
θINT-BOTTOM
Power Dissipation (W)
TCASE_BOTTOM(°C)
θINT-LEADS
+
–
TLEADS(°C)
+
–
TCASE_TOP(°C)
+
–
nn
Protect the module from overvoltage transients imposed by the
system that would exceed maximum ratings and induce stresses:
The module primary/secondary voltage ranges shall not be
exceeded. An internal overvoltage lockout function prevents
operation outside of the normal operating primary range. Even
when disabled, the powertrain is exposed to the applied voltage
and power MOSFETs must withstand it.
Total load capacitance at the secondary of the BCM module shall
not exceed the specified maximum. Owing to the wide bandwidth
and low secondary impedance of the module, low-frequency
bypass capacitance and significant energy storage may be more
densely and efficiently provided by adding capacitance at the
primary of the module. At frequencies <500kHz the module
appears as an impedance of RSEC between the source and load.
Within this frequency range, capacitance at the primary appears as
effective capacitance on the secondary per the relationship
defined in Eq. (13).
CSEC_EXT =
CPRI_EXT
K2
Figure 22 — Top case, Bottom case and leads thermal model
Alternatively, equations can be written around this circuit and
analyzed algebraically:
TINT – PD1 • θINT-TOP = TCASE_TOP
TINT – PD2 • θINT-BOTTOM = TCASE_BOTTOM
TINT – PD3 • θINT-LEADS = TLEADS
PDTOTAL = PD1+ PD2+ PD3
Where TINT represents the internal temperature and PD1, PD2, and
PD3 represent the heat flow through the top side, bottom side, and
leads respectively.
Thermal Resistance Top
MAX INTERNAL TEMP
θINT-TOP
(13)
Thermal Resistance Bottom
θINT-BOTTOM
This enables a reduction in the size and number of capacitors used
in a typical system.
Power Dissipation (W)
TCASE_BOTTOM(°C)
Thermal Resistance Leads
θINT-LEADS
TLEADS(°C)
Figure 23 — Top case and leads thermal model
BCM® Bus Converter
Page 26 of 30
Rev 1.3
09/2017
+
–
TCASE_TOP(°C)
+
–
BCM6123xD1E5126yzz
Figure 23 shows a scenario where there is no bottom side cooling.
In this case, the heat flow path to the bottom is left open and the
equations now simplify to:
VPRI
TINT – PD1 • θINT-TOP = TCASE_TOP
ZIN_EQ1
BCM®1
ZOUT_EQ1
R0_1
VSEC
TINT – PD3 • θINT-LEADS = TLEADS
PDTOTAL = PD1+ PD3
ZIN_EQ2
BCM®2
ZOUT_EQ2
R0_2
+ DC
Thermal Resistance Top
Load
MAX INTERNAL TEMP
θINT-TOP
Thermal Resistance Bottom
Thermal Resistance Leads
θINT-BOTTOM
Power Dissipation (W)
TCASE_BOTTOM(°C)
θINT-LEADS
TLEADS(°C)
ZIN_EQn
TCASE_TOP(°C)
+
–
BCM®n
ZOUT_EQn
R0_n
Figure 25 — BCM module array
Figure 24 — Top case thermal model
Fuse Selection
Figure 24 shows a scenario where there is no bottom side and
leads cooling. In this case, the heat flow paths to the bottom and
leads are left open and the equations now simplify to:
In order to provide flexibility in configuring power systems
ChiP modules are not internally fused. Input line fusing
of ChiP products is recommended at system level to provide
thermal protection in case of catastrophic failure.
TINT – PD1 • θINT-TOP = TCASE_TOP
PDTOTAL = PD1
Please note that Vicor has a suite of online tools, including a
simulator and thermal estimator which greatly simplify the task of
determining whether or not a BCM thermal configuration is valid
for a given condition. These tools can be found at:
http://www.vicorpower.com/powerbench..
The fuse shall be selected by closely matching system
requirements with the following characteristics:
nn
Current rating
(usually greater than maximum current of BCM module)
nn
Maximum voltage rating
(usually greater than the maximum possible input voltage)
Current Sharing
nn
Ambient temperature
The performance of the SAC™ topology is based on efficient
transfer of energy through a transformer without the need of
closed loop control. For this reason, the transfer characteristic
can be approximated by an ideal transformer with a positive
temperature coefficient series resistance.
nn
Nominal melting I2t
This type of characteristic is close to the impedance characteristic
of a DC power distribution system both in dynamic (AC) behavior
and for steady state (DC) operation.
BCM modules are capable of reverse power operation. Once the
unit is started, energy will be transferred from the secondary back
to the primary whenever the secondary voltage exceeds VPRI • K.
The module will continue operation in this fashion for as long as
no faults occur.
When multiple BCM modules of a given part number are
connected in an array they will inherently share the load current
according to the equivalent impedance divider that the system
implements from the power source to the point of load.
Some general recommendations to achieve matched array
impedances include:
nn
Dedicate common copper planes within the PCB
to deliver and return the current to the modules.
nn
Provide as symmetric a PCB layout as possible among modules
nn
An input filter is required for an array of BCMs in order to
prevent circulating currents.
nn
Recommend fuse: See safety agency approvals.
Reverse Operation
Transient operation in reverse is expected in cases where there is
significant energy storage on the output and transient voltages
appear on the input.
The BCM6123xD1E5126y0R and BCM6123xD1E5126y0P are both
qualified for continuous operation in reverse power condition. A
primary voltage of VPRI_DC > VPRI_UVLO+_R must be applied first to
allow the primary reference controller and power train to start.
Continuous operation in reverse is then possible after a
successful startup.
For further details see AN:016 Using BCM Bus Converters
in High Power Arrays.
BCM® Bus Converter
Page 27 of 30
Rev 1.3
09/2017
BCM6123xD1E5126yzz
BCM Module Through Hole Package Mechanical Drawing and Recommended Land Pattern
63.34±.38
2.494±.015
11.43
.450
31.67
1.247
0
1.52
.060
(2) PL.
11.40
.449
0
22.80±.13
.898±.005
0
1.52
.060
(4) PL.
0
1.02
.040
(3) PL.
TOP VIEW (COMPONENT SIDE)
.05 [.002]
SEATING
7.21±.10
.284±.004
.
PLANE
.41
.016
(9) PL.
30.91
1.217
0
30.91
1.217
4.17
.164
(9) PL.
8.25
.325
2.75
.108
2.75
.108
8.00
.315
0
0
1.38
.054
1.38
.054
4.13
.162
8.00
.315
0
8.25
.325
BOTTOM VIEW
0
8.00±.08
.315±.003
4.13±.08
.162±.003
1.38±.08
.054±.003
8.00±.08
.315±.003
+VPRI
0
-VSEC
TM / SER-OUT
0
EN
VAUX / SER-IN
-VPRI
2.03
.080
PLATED THRU
.25 [.010]
ANNULAR RING
(2) PL.
2.75±.08
.108±.003
-VSEC
8.25±.08
.325±.003
RECOMMENDED HOLE PATTERN
(COMPONENT SIDE)
1- RoHS COMPLIANT PER CST-0001 LATEST REVISION.
2- UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE MM / [INCH]
Rev 1.3
09/2017
2.75±.08
.108±.003
+VSEC
NOTES:
BCM® Bus Converter
Page 28 of 30
8.25±.08
.325±.003
+VSEC
0
1.38±.08
.054±.003
30.91±.08
1.217±.003
30.91±.08
1.217±.003
1.52
.060
PLATED THRU
.25 [.010]
ANNULAR RING
(3) PL.
2.03
.080
PLATED THRU
.38 [.015]
ANNULAR RING
(4) PL.
BCM6123xD1E5126yzz
Revision History
Revision
Date
1.0
08/4/16
Release of current data sheet with new part number
1.1
01/16/17
Updated the output resistance in the reverse direction
1.2
08/04/17
Updated height specification
1, 21, 28
1.3
09/15/17
Updated volume specification
21
BCM® Bus Converter
Page 29 of 30
Description
Rev 1.3
09/2017
Page Number(s)
n/a
9
BCM6123xD1E5126yzz
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/dc-dc/isolated-fixed-ratio/hv-bus-converter-module for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
The products described on this data sheet are protected by the following U.S. Patents Numbers:
6,911,848; 6,930,893; 6,934,166; 7,145,786; 7,782,639; 8,427,269 and for use under 6,975,098 and 6,984,965.
Contact Us: http://www.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: [email protected]
Technical Support: [email protected]
©2017 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
BCM® Bus Converter
Page 30 of 30
Rev 1.3
09/2017
Similar pages