Click on Series name for product info on aimtec.com Series AME25-CJZ 25 Watt | AC-DC / DC-DC Converter Picture coming soon FEATURES: I/O Isolation 3000VAC Operating Temp: -25 °C to +70 °C Input: 85-264VAC, 47-63Hz, or 120-370VDC Over current, Over Voltage Protection Continuous Short circuit protection Energy Star compliant Compact package Efficiency up to 87% Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 120-370 120-370 120-370 120-370 120-370 120-370 120-370 AME25-3.3SCJZ AME25-5SCJZ AME25-9SCJZ AME25-12SCJZ AME25-15SCJZ AME25-24SCJZ AME25-48SCJZ Output Voltage (V) Output Current max (A) 3.3 5 9 12 15 24 48 Maximum capacitive Load (µF) Efficiency 230VAC (%) 48000 12240 5600 5400 2400 1440 500 73 74 78 82 83 85 87 4.1 4.1 2.5 2.1 1.6 1.1 0.5 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 230VAC/50Hz Recommended slow blow type 16 30 3.15 Maximum 600 340 Units mA mA A A mA A 0.3 Output Specifications Parameters Conditions Typical Voltage accuracy Line regulation Load regulation (single output) Load Regulation (dual output) Load Regulation (triple & asymmetric separated output) Minimum load Full load, main output Full load, auxiliary output 10-100% load 10-100% Balanced load 10-100% Balanced load, main output 10-100% Balanced load, auxiliary output Single output Others Ripple & Noise * 115VAC, 20MHz bandwidth 230VAC, 20MHz bandwidth Hold-up time ±2 ±0.5 ±1.5 ±1 ±2 ±3 ±5 0 10 50 15 80 Voltage adjustment range Maximum Units % % % % % ±10 % % mV p-p ms ms % of Vout Rated Units 3000 500 VAC VDC 150 Isolation Specifications Parameters Tested I/O voltage Isolation voltage between Main and Auxiliary output Isolation Resistance www.aimtec.com Conditions Typical 60 sec 60 sec >1000 Tel: +1 514 620 2722 MΩ Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 1 of 5 North America only Series AME25-CJZ 25 Watt | AC-DC / DC-DC Converter General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class I Over current protection ≥110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery oC Operating temperature See derating curve -25 to +70 oC Storage temperature -25 to +105 oC Maximum Case temperature 100 Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 120 g Dimensions (L x W x H) 2.76 x 1.89 x 0.93 inches 70.0 x 48.0 x 23.5 mm MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals cULus, CE Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC/EN/UL 60950-1 EN55022, class B IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11 Class 2 Dimensions 3 2 Bottom View 9 8 7 6 5 1 4.00 (0.16) 1 2 4 5 6 7 8 9 3 4 62.00 (2.44) Top View 5.75 (0.23) 20.00 (0.79) 48.00 (1.89) 12.50 (0.49) 4.00 (0.16) 70.00 (2.76) 4.00 (0.16) DIV: 10.00 (0.40) Ø 1.50 (Ø 0.06) 1.00 (0.04) www.aimtec.com 6.00 (0.24) 23.50 (0.93) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 2 of 5 North America only Series AME25-CJZ 25 Watt | AC-DC / DC-DC Converter Pin Out Specifications Pin Single 1 2 3 4 5 6 7 8 9 Ground AC Input (N) AC Input (L) Trim -V Output No pin No pin No pin +V Output Derating Free Air Convection at 25°C 100 100 80 Output Power (%) Output power (%) Free Air Convection Safe Operating Area 70 Input 100-240VAC or 120-340VDC 60 40 80 75 60 Safe Operating Area 40 20 20 0 - 25 -20 -10 0 20 40 55 70 60 80 0 85 100 (100) (120) 100 Ambient Temperature º C 240 (320) 264 (350) Input Voltage VAC (VDC) Typical application circuits FUSE 3.15A/300V Single Output NTC + Vout AC L AC L MOV S14K350 AC AC N DC AC N Earth/GND Model Single 3.3 & 5 Vout Single 9 Vout Single 12 & 15 Vout Single 24 Vout Single 48 Vout www.aimtec.com C2 330 µF 330 µF 330 µF 120 µF 68 µF + Vout + TVS C1 C2 1µF/50V ‐ Vout ‐ Vout TVS 7V 12V 20V 30V 64V Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 3 of 5 North America only Series AME25-CJZ 25 Watt | AC-DC / DC-DC Converter Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AME20‐3.3SCJZ Trim down % 1 Vout (VDC) 3.27 181.7 Rt down (KΩ) Trim up % 1 3.33 Vout (VDC) 174.371 Rt up (KΩ) AME20‐5SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) AME20‐9SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) www.aimtec.com 2 3.23 84.657 3 3.2 59.638 4 3.17 45.602 5 3.14 36.62 6 3.1 28.7 7 3.07 24.517 8 3.04 21.275 9 3 17.939 10 2.97 15.957 2 3.37 63.611 3 3.4 42.843 4 3.43 32.178 5 3.47 24.053 6 3.5 20.166 7 3.53 17.322 8 3.56 15.153 9 3.6 12.95 10 3.63 11.656 1 4.95 160.7 2 4.9 78.2 3 4.85 50.7 4 4.8 36.95 5 4.75 28.7 6 4.7 23.2 7 4.65 19.271 8 4.6 16.325 9 4.55 14.033 10 4.5 12.2 1 5.05 164 2 5.1 81.5 3 5.15 54 4 5.2 40.25 5 5.25 32 6 5.3 26.5 7 5.35 22.571 8 5.4 19.625 9 5.45 17.333 10 5.5 15.5 2 3 4 8.82 8.73 8.64 221.43 153.157 116.145 5 8.55 92.925 6 8.46 76.997 7 8.37 65.393 8 8.28 56.562 9 8.19 49.617 10 8.1 44.011 1 8.91 389.533 1 9.09 2 9.18 3 9.27 4 9.36 5 9.45 6 9.54 7 9.63 8 9.72 9 9.81 10 9.9 328.532 126.639 78.148 56.357 43.975 35.99 30.412 26.297 23.134 20.629 Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 4 of 5 North America only Series AME25-CJZ 25 Watt | AC-DC / DC-DC Converter AME20‐12SCJZ Trim down % Vout (VDC) 1 11.88 183.233 1 12.12 2 11.76 111.59 2 12.24 3 11.64 79.474 3 12.36 4 11.52 61.246 4 12.48 5 11.4 49.499 5 12.6 6 11.28 41.299 6 12.72 7 11.16 35.249 7 12.84 8 11.04 30.602 8 12.96 9 10.92 26.921 9 13.08 10 10.8 23.933 10 13.2 Rt up (KΩ) 211.778 57.03 32.596 22.642 17.238 13.845 11.516 9.819 8.527 7.511 2 3 14.7 14.55 304 199.833 2 3 15.3 15.45 4 14.4 147.75 4 15.6 5 14.25 116.5 5 15.75 6 14.1 95.667 6 15.9 7 13.95 80.786 7 16.05 8 13.8 69.625 8 16.2 9 13.65 60.944 9 16.35 10 13.5 54 10 16.5 30.25 24 19.833 16.857 14.625 12.889 11.5 Vout (VDC) 1 2 3 4 5 6 23.76 23.52 23.28 23.04 22.8 22.56 471.081 287.942 205.845 159.249 129.221 108.258 1 2 3 4 5 6 24.24 24.48 24.72 24.96 25.2 25.44 7 22.32 92.793 7 25.68 8 22.08 80.914 8 25.92 9 21.84 71.504 9 26.16 10 21.6 63.865 10 26.4 Rt up (KΩ) 239.556 13.15 11.232 9.771 8.622 Vout (VDC) Rt down (KΩ) Trim up % AME20‐15SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) AME20‐24SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % AME20‐48SCJZ Trim down % 1 14.85 616.5 1 15.15 124 61.5 64.606 Vout (VDC) 1 47.52 5501.011 1 48.48 2 47.04 2921.325 2 48.96 Rt up (KΩ) 420.217 191.396 Vout (VDC) Rt down (KΩ) Trim up % 40.667 36.982 25.728 19.619 15.783 3 4 5 6 7 8 9 10 46.56 46.08 45.6 45.12 44.64 44.16 43.68 43.2 1974.775 1483.386 1182.489 979.298 832.871 722.336 635.938 566.549 3 4 5 6 7 8 9 10 49.44 49.92 50.4 50.88 51.36 51.84 52.32 52.8 123.671 91.211 72.163 59.636 50.773 44.17 39.06 34.99 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 5 of 5 North America only