M29DW641F 64 Mbit (4Mb x16, Multiple Bank, Page, Boot Block) 3V Supply Flash Memory Features ■ Supply voltage – VCC = 2.7V to 3.6V for Program, Erase and Read – VPP/WP=12V for Fast Program (optional) ■ Asynchronous Page Read mode – Page Width 8 Words – Page Access 25, 30ns – Random Access: 60, 70ns ■ Programming Time – 10µs per Word typical – 4 Words at-a-time Program ■ Memory blocks – Quadruple Bank Memory Array: 8Mbit+24Mbit+24Mbit+8Mbit – Parameter Blocks (at Top and Bottom) ■ Dual Operations – While Program or Erase in a group of banks (from 1 to 3), Read in any of the other banks ■ Program/Erase Suspend and Resume modes – Read from any Block during Program Suspend – Read and Program another Block during Erase Suspend ■ Unlock Bypass Program command – Faster Production/Batch Programming ■ Common Flash Interface – 64 bit Security Code ■ 100,000 Program/Erase cycles per block ■ Low power consumption – Standby and Automatic Standby ■ Extended Memory Block – Extra block used as security block or to store additional information December 2007 TSOP48 (N) 12 x 20mm FBGA TFBGA48 (ZE) 6 x 8mm ■ Hardware Block Protection – VPP/WP Pin for fast program and write protect of the four outermost parameter blocks ■ Software Block Protection – Standard Protection – Password Protection ■ Electronic Signature – Manufacturer code: 0020h – Device code: 227Eh + 2203h + 2200h ■ ECOPACK® packages Rev 5 1/80 www.numonyx.com 1 Contents M29DW641F Contents 1 Summary description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3 4 5 2/80 2.1 Address Inputs (A0-A21) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.2 Data Inputs/Outputs (DQ0-DQ15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.3 Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.4 Output Enable (G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.5 Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.6 VPP/Write Protect (VPP/WP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.7 Reset/Block Temporary Unprotect (RP) . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.8 Ready/Busy Output (RB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.9 VCC Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.10 VSS Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.1 Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.2 Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.3 Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.4 Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.5 Automatic Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.6 Special Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.6.1 Read Electronic Signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.6.2 Verify Extended Block Protection indicator . . . . . . . . . . . . . . . . . . . . . . 17 3.6.3 Verify Block Protection status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.6.4 Hardware Block Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.6.5 Temporary Unprotection of High voltage Protected Blocks . . . . . . . . . . 18 Hardware Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.1 Write Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.2 Temporary Block Unprotect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Software Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 M29DW641F 5.1 5.2 6 Contents Standard Protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.1.1 Block Lock/Unlock Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.1.2 Non-volatile Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Password Protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.2.1 Block Lock/Unlock Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.2.2 Non-volatile Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Command interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.1 6.2 6.3 Standard commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.1.1 Read/Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.1.2 Auto Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.1.3 Read CFI Query command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6.1.4 Chip Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6.1.5 Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 6.1.6 Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 6.1.7 Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6.1.8 Program Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6.1.9 Program Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6.1.10 Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6.1.11 Verify command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Fast Program commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 6.2.1 Double Word Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 6.2.2 Quadruple Word Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 6.2.3 Unlock Bypass command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 6.2.4 Unlock Bypass Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 6.2.5 Unlock Bypass Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Block Protection commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.3.1 Enter Extended Block command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.3.2 Exit Extended Block command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.3.3 Set Extended Block Protection bit command . . . . . . . . . . . . . . . . . . . . . 33 6.3.4 Verify Extended Block Protection bit command . . . . . . . . . . . . . . . . . . . 34 6.3.5 Password Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 6.3.6 Password Verify command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 6.3.7 Password Protection Unlock command . . . . . . . . . . . . . . . . . . . . . . . . . 35 6.3.8 Set Password Protection mode command . . . . . . . . . . . . . . . . . . . . . . . 35 6.3.9 Verify Password Protection mode command . . . . . . . . . . . . . . . . . . . . . 35 6.3.10 Set Standard Protection mode command . . . . . . . . . . . . . . . . . . . . . . . 35 3/80 Contents 7 M29DW641F 6.3.11 Verify Standard Protection mode command . . . . . . . . . . . . . . . . . . . . . 36 6.3.12 Set Non-Volatile Modify Protection bit command . . . . . . . . . . . . . . . . . . 36 6.3.13 Verify Non-volatile Modify Protection bit command . . . . . . . . . . . . . . . . 36 6.3.14 Clear Non-volatile Modify Protection bit command . . . . . . . . . . . . . . . . 36 6.3.15 Set Lock bit command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6.3.16 Clear Lock bit command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.3.17 Verify Lock bit command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.3.18 Set Lock-Down bit command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.3.19 Verify Lock-Down bit command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.1 Data polling bit (DQ7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.2 Toggle bit (DQ6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.3 Error bit (DQ5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 7.4 Erase timer bit (DQ3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 7.5 Alternative toggle bit (DQ2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 8 Dual Operations and Multiple Bank architecture . . . . . . . . . . . . . . . . . 45 9 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 10 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 11 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 12 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Appendix A Block addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Appendix B Common Flash Interface (CFI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Appendix C Extended Memory Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 C.1 Factory Locked section of the Extended Block . . . . . . . . . . . . . . . . . . . . . 71 C.2 Customer Lockable section of the Extended Block . . . . . . . . . . . . . . . . . . 72 Appendix D High voltage Block Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 D.1 4/80 Programmer technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 M29DW641F D.2 Contents In-system technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 5/80 List of tables M29DW641F List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Table 27. Table 28. Table 29. Table 30. Table 31. Table 32. Table 33. Table 34. Table 35. Table 36. Table 37. 6/80 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Bank architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Read Electronic Signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Block Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Hardware Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Block Protection status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Standard commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Fast Program commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Block Protection commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Protection command addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Program, Erase Times and Program, Erase Endurance cycles . . . . . . . . . . . . . . . . . . . . . 40 Status Register bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Dual Operations allowed in other banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Dual Operations allowed in same bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Operating and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Device capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Read AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Write AC characteristics, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Write AC characteristics, Chip Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Toggle and alternative toggle bits AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Reset/Block Temporary Unprotect AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, package mechanical data . . . 58 TFBGA48 6x8mm - 6x8 Active Ball Array, 0.8mm pitch, package mechanical data . . . . . 59 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Block Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Query structure overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 CFI Query Identification String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 CFI Query System Interface Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Device Geometry Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Primary Algorithm-specific extended Query table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Security Code Area. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Extended Block Address and Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Programmer technique Bus Operations, 8-bit or 16-bit mode . . . . . . . . . . . . . . . . . . . . . . 74 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 M29DW641F List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 TSOP connections (top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 TFBGA48 connections (top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Block addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Block Protection state diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Software Protection scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Data polling flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Toggle flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 AC measurement load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Random Read AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Page Read AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Write AC waveforms, Write Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Write AC waveforms, Chip Enable controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Toggle and alternative toggle bits mechanism, Chip Enable controlled . . . . . . . . . . . . . . . 54 Toggle and alternative toggle bits mechanism, Output Enable controlled . . . . . . . . . . . . . 55 Reset/Block Temporary Unprotect AC waveforms (no Program/Erase ongoing) . . . . . . . . 55 Reset/Block Temporary Unprotect during Program/Erase Operation AC waveforms . . . . 56 Accelerated Program timing waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, package outline . . . . . . . . . . . 58 TFBGA48 6x8mm - 6x8 Active Ball Array, 0.8mm pitch, package outline . . . . . . . . . . . . . 59 Programmer equipment Group Protect flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Programmer equipment Chip Unprotect flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 In-System equipment Group Protect flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 In-System equipment Chip Unprotect flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 7/80 Summary description 1 M29DW641F Summary description The M29DW641F is a 64 Mbit (4Mb x16) non-volatile memory that can be read, erased and reprogrammed. These operations can be performed using a single low voltage (2.7 to 3.6V) supply. On power-up the memory default to its Read mode. The device features an asymmetrical block architecture, with 16 parameter and 126 main blocks, divided into four Banks, A, B, C and D, providing Multiple Bank Operations. While programming or erasing is underway in one group of banks (from 1 to 3), reading can be conducted in any of the other banks. Table 2 summarizes the bank architecture. Eight of the Parameter Blocks are at the top of the memory address space, and eight are at the bottom. Program and Erase commands are written to the Command Interface of the memory. An onchip Program/Erase Controller simplifies the process of programming or erasing the memory by taking care of all of the special operations that are required to update the memory contents. The end of a Program or Erase Operation can be detected and any error conditions identified. The command set required to control the memory is consistent with JEDEC standards. The Chip Enable, Output Enable and Write Enable signals control the Bus Operation of the memories. They allow simple connection to most microprocessors, often without additional logic. The M29DW641F has one extra 128 Word block (Extended Block) that can be accessed using a dedicated command. The Extended Block can be protected and so is useful for storing security information. However the protection is irreversible, once protected the protection cannot be undone. Each block can be erased independently, so it is possible to preserve valid data while old data is erased. The device features different levels of hardware and software block protection to avoid unwanted program or erase (modify). The software block protection features are available in 16 bit memory organization only: ● ● Hardware Protection: – The VPP/WP provides a hardware protection of the four outermost parameter blocks (two at the top and two at the bottom of the address space). – The RP pin temporarily unprotects all the blocks previously protected using a High voltage Block Protection technique (see Appendix D: High voltage Block Protection). Software Protection – Standard Protection – Password Protection The memory is offered in TSOP48 (12x20mm) and TFBGA48 (6x8mm, 0.8mm pitch) packages. In order to meet environmental requirements, Numonyx offers the M29DW641F in ECOPACK® packages. ECOPACK packages are Lead-free. The category of second Level Interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. The memory is supplied with all the bits erased (set to ’1’). 8/80 M29DW641F Summary description Figure 1. Logic diagram VCC VPP/WP 22 15 A0-A21 DQ0-DQ15 W M29DW641F E G RB RP VSS Table 1. AI11505 Signal names A0-A21 Address Inputs DQ0-DQ15 Data Inputs/Outputs E Chip Enable G Output Enable W Write Enable RP Reset/Block Temporary Unprotect RB Ready/Busy Output VCC Supply voltage VPP/WP VPP/Write Protect VSS Ground NC Not Connected Internally Table 2. Bank Bank architecture Bank size Parameter Blocks Main Blocks No. of Blocks Block size No. of Blocks Block size A 8 Mbit 8 4 KWord 15 32 KWord B 24 Mbit — — 48 32 KWord C 24 Mbit — — 48 32 KWord D 8 Mbit 8 4 KWord 15 32 KWord 9/80 Summary description Figure 2. M29DW641F TSOP connections (top view through package) A15 A14 A13 A12 A11 A10 A9 A8 A19 A20 W RP A21 VPP/WP RB A18 A17 A7 A6 A5 A4 A3 A2 A1 1 48 12 37 M29DW641F 13 36 24 25 A16 NC VSS DQ15 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 G VSS E A0 1. Balls are shorted together via the substrate but not connected to the die. 10/80 M29DW641F Summary description Figure 3. TFBGA48 connections (top view through package) 1 2 3 4 5 6 A A3 A7 RB W A9 A13 B A4 A17 VPP/WP RP A8 A12 C A2 A6 A18 A21 A10 A14 D A1 A5 A20 A19 A11 A15 E A0 DQ0 DQ2 DQ5 DQ7 A16 F E DQ8 DQ10 DQ12 DQ14 NC G G DQ9 DQ11 VCC DQ13 DQ15 H VSS DQ1 DQ3 DQ4 DQ6 VSS AI11252b 1. Balls are shorted together via the substrate but not connected to the die. 11/80 Summary description Figure 4. M29DW641F Block addresses Address lines A21-A0 000000h 000FFFh 200000h 8 Kbyte or 4 KWord 207FFFh Total of 8 Parameter Blocks 007000h Bank A 007FFFh 008000h 00FFFFh 64 Kbyte or 32 KWord Total of 48 Main Blocks Bank C 378000h 8 Kbyte or 4 KWord 37FFFFh 380000h 64 Kbyte or 32 KWord 387FFFh 64 Kbyte or 32 KWord 64 Kbyte or 32 KWord Total of 15 Main Blocks Total of 15 Main Blocks 078000h 07FFFFh 080000h 087FFFh 3F0000h 64 Kbyte or 32 KWord Bank D 64 Kbyte or 32 KWord 3F7FFFh 3F8000h 3F8FFFh 64 Kbyte or 32 KWord 8 Kbyte or 4 KWord Total of 8 Parameter Blocks Total of 48 Main Blocks Bank B 1F8000h 1FFFFFh 64 Kbyte or 32 KWord 3FF000h 3FFFFFh 8 Kbyte or 4 KWord AI05555 1. Also see Appendix A, Table 28 for a full listing of the Block Addresses. 12/80 M29DW641F 2 Signal descriptions Signal descriptions See Figure 1: Logic diagram, and Table 1: Signal names, for a brief overview of the signals connected to this device. 2.1 Address Inputs (A0-A21) The Address Inputs select the cells in the memory array to access during Bus Read Operations. During Bus Write Operations they control the commands sent to the Command Interface of the internal state machine. 2.2 Data Inputs/Outputs (DQ0-DQ15) The Data I/O output the data stored at the selected address during a Bus Read Operation. During Bus Write Operations they represent the commands sent to the Command Interface of the Program/Erase Controller. 2.3 Chip Enable (E) The Chip Enable, E, activates the memory, allowing Bus Read and Bus Write Operations to be performed. When Chip Enable is High, VIH, all other pins are ignored. 2.4 Output Enable (G) The Output Enable, G, controls the Bus Read Operation of the memory. 2.5 Write Enable (W) The Write Enable, W, controls the Bus Write Operation of the memory’s Command Interface. 2.6 VPP/Write Protect (VPP/WP) The VPP/Write Protect pin is both a power supply and a write protect pin. When VPP/Write Protect is Low, VIL, it is seen as a write protect pin protecting the four outermost parameter blocks (two at the top, and two at the bottom of the address space). Program and erase Operations in these blocks are ignored while VPP/Write Protect is Low, even when RP is at VID. When VPP/Write Protect is High, VIH, the memory reverts to the previous protection state of the four outermost parameter blocks. Program and Erase Operations can now modify the data in these blocks unless the blocks are protected using Block Protection. Applying VPPH to the VPP/WP pin will temporarily unprotect any block previously protected (including the four outermost parameter blocks) using a High voltage Block Protection 13/80 Signal descriptions M29DW641F technique (In-System or Programmer technique). See Table 6: Hardware Protection for details. The VPP/Write Protect pin must not be left floating or unconnected or the device may become unreliable. A 0.1µF capacitor should be connected between the VPP/Write Protect pin and the VSS Ground pin to decouple the current surges from the power supply. The PCB track widths must be sufficient to carry the currents required during Unlock Bypass Program, IPP. 2.7 Reset/Block Temporary Unprotect (RP) The Reset/Block Temporary Unprotect pin can be used to apply a Hardware Reset to the memory or to temporarily unprotect all the blocks previously protected using a High voltage Block Protection technique (In-System or Programmer technique). Note that if VPP/WP is at VIL, then the four outermost parameter blocks will remain protected even if RP is at VID. A Hardware Reset is achieved by holding Reset/Block Temporary Unprotect Low, VIL, for at least tPLPX. If RP is asserted during a Program or Erase Operation, the RB pin remains Low (busy), until the internal Reset Operation is completed, which requires a tPLYH time (see Figure 18: Reset/Block Temporary Unprotect during Program/Erase Operation AC waveforms). The RB signal can be monitored by the system microprocessor to determine whether the Reset Operation is completed or not. If RP is asserted when no Program or Erase Operation is ongoing, the RB pin remains high, VIH. A tPHEL or tPHGL delay elapses before the Reset Operation is completed and RP returns to High, VIH. After this delay, the memory is ready for Bus Read and Bus Write Operations. Holding RP at VID will temporarily unprotect all the blocks previously protected using a High voltage Block Protection technique. Program and Erase Operations on all blocks will be possible. The transition from VIH to VID must be slower than tPHPHH. See the Ready/Busy Output section, Table 24: Reset/Block Temporary Unprotect AC characteristics and Figure 18: Reset/Block Temporary Unprotect during Program/Erase Operation AC waveforms for more details. 2.8 Ready/Busy Output (RB) The Ready/Busy pin is an open-drain output that can be used to identify when the device is performing a Program or Erase Operation. During Program or Erase Operations Ready/Busy is Low, VOL. Ready/Busy is high-impedance during Read mode, Auto Select mode and Erase Suspend mode. After a Hardware Reset, Bus Read and Bus Write Operations cannot begin until Ready/Busy becomes high-impedance. See Table 24 and Figure 18: Reset/Block Temporary Unprotect during Program/Erase Operation AC waveforms. The use of an open-drain output allows the Ready/Busy pins from several memories to be connected to a single pull-up resistor. A Low will then indicate that one, or more, of the memories is busy. 14/80 M29DW641F 2.9 Signal descriptions VCC Supply voltage VCC provides the power supply for all operations (Read, Program and Erase). The Command Interface is disabled when the VCC Supply voltage is less than the Lockout voltage, VLKO. This prevents Bus Write Operations from accidentally damaging the data during power up, power down and power surges. If the Program/Erase Controller is programming or erasing during this time then the operation aborts and the memory contents being altered will be invalid. A 0.1µF capacitor should be connected between the VCC Supply voltage pin and the VSS Ground pin to decouple the current surges from the power supply. The PCB track widths must be sufficient to carry the currents required during Program and Erase Operations, ICC3. 2.10 VSS Ground VSS is the reference for all voltage measurements. The device features two VSS pins both of which must be connected to the system ground. 15/80 Bus Operations 3 M29DW641F Bus Operations There are five standard Bus Operations that control the device. These are Bus Read (Random and Page modes), Bus Write, Output Disable, Standby and Automatic Standby. Dual Operations are possible in the M29DW641F, thanks to their multiple bank architecture. While programming or erasing in one banks, Read Operations are possible in any of the other banks. Write Operations are only allowed in one bank at a time. See Table 3: Bus Operations, for a summary. Typically glitches of less than 5ns on Chip Enable, Write Enable, and Reset/Block Temporary Unprotect pins are ignored by the memory and do not affect Bus Operations. 3.1 Bus Read Bus Read Operations read from the memory cells, or specific registers in the Command Interface. To speed up the Read Operation the memory array can be read in Page mode where data is internally read and stored in a page buffer. The Page has a size of 8 Words and is addressed by the address inputs A0-A2. A valid Bus Read Operation involves setting the desired address on the Address Inputs, applying a Low signal, VIL, to Chip Enable and Output Enable and keeping Write Enable High, VIH. The Data Inputs/Outputs will output the value, see Figure 11: Random Read AC waveforms, Figure 12: Page Read AC waveforms, and Table 20: Read AC characteristics, for details of when the output becomes valid. 3.2 Bus Write Bus Write Operations write to the Command Interface. A valid Bus Write Operation begins by setting the desired address on the Address Inputs. The Address Inputs are latched by the Command Interface on the falling edge of Chip Enable or Write Enable, whichever occurs last. The Data Inputs/Outputs are latched by the Command Interface on the rising edge of Chip Enable or Write Enable, whichever occurs first. Output Enable must remain High, VIH, during the whole Bus Write Operation. See Figure 13 and Figure 14, Write AC Waveforms, and Table 21 and Table 22, Write AC Characteristics, for details of the timing requirements. 3.3 Output Disable The Data Inputs/Outputs are in the high impedance state when Output Enable is High, VIH. 3.4 Standby When Chip Enable is High, VIH, the memory enters Standby mode and the Data Inputs/Outputs pins are placed in the high-impedance state. To reduce the Supply current to the Standby Supply current, ICC2, Chip Enable should be held within VCC ± 0.2V. For the Standby current level see Table 19: DC characteristics. During program or Erase Operations the memory will continue to use the Program/Erase Supply current, ICC3, for Program or Erase Operations until the operation completes. 16/80 M29DW641F 3.5 Bus Operations Automatic Standby If CMOS levels (VCC ± 0.2V) are used to drive the bus and the bus is inactive for 300ns or more the memory enters Automatic Standby where the internal Supply current is reduced to the Standby Supply current, ICC2. The Data Inputs/Outputs will still output data if a Bus Read Operation is in progress. 3.6 Special Bus Operations Additional Bus Operations can be performed to read the Electronic Signature, verify the Protection status of the Extended Memory Block (second section), and apply or remove Block Protection. These Bus Operations are intended for use by programming equipment and are not usually used in applications. They require VID to be applied to some pins. 3.6.1 Read Electronic Signature The memory has two codes, the Manufacturer code and the Device code used to identify the memory. These codes can accessed by performing Read Operations with control signals and addresses set as shown in Table 3: Bus Operations. These codes can also be accessed by issuing an Auto Select command (see Section 6: Command interface, Section 6.1.2: Auto Select command). 3.6.2 Verify Extended Block Protection indicator The Extended Block is divided in two sections of which one is Factory Locked and the second one is either Customer Lockable or Customer Locked. The Protection status of the second section of the Extended Block (Customer Lockable or Customer Locked) can be accessed by reading the Extended Block Protection indicator. This is done by applying the signals listed in Table 5: Block Protection. The Protection status of the Extended Block is then output on bits DQ7 and DQ6 of the Data Input/Outputs. (see Table 3: Bus Operations). The Protection status of the Extended Block can also be accessed by issuing an Auto Select command (see Section 6: Command interface, Section 6.1.2: Auto Select command). 3.6.3 Verify Block Protection status The Protection status of a Block can be directly accessed by performing a Read Operation with control signals and addresses set as shown in Table 5: Block Protection. If the Block is protected, then 0001h is output on Data Input/Outputs, otherwise 0000h is output. 3.6.4 Hardware Block Protect The VPP/WP pin can be used to protect the four outermost parameter blocks. When VPP/WP is at VIL the four outermost parameter blocks are protected and remain protected regardless of the Block Protection status or the Reset/Block Temporary Unprotect pin state. 17/80 Bus Operations 3.6.5 M29DW641F Temporary Unprotection of High voltage Protected Blocks The RP pin can be used to temporarily unprotect all the blocks previously protected using the In-System or the Programmer Protection technique (High voltage techniques). Refer to Section 2.7: Reset/Block Temporary Unprotect (RP) in the Section 2: Signal descriptions. Table 3. Bus Operations(1) Operation E G Address Inputs Data Inputs/Outputs A21-A0 DQ15-DQ0 W Bus Read VIL VIL VIH Cell Address Data Output Bus Write VIL VIH VIL Command Address Data Input X VIH VIH X Hi-Z VIH X X X Hi-Z Output Disable Standby 1. X = VIL or VIH. Table 4. Read Electronic Signature(1) Address Inputs Read cycle E G W A21A10 A9 A8 A7-A6 A5-A4 A3 A2 A1 A0 Manufacturer code X Device code (Cycle 1) Device code (Cycle 2) VIL VIL VIH Device code (Cycle 3) 1. X = VIL or VIH. 18/80 Data Inputs/Outputs X VID X DQ15-DQ0 VIL VIL VIL VIL 0020h VIL VIL VIL VIH 227Eh VIH VIH VIH VIL 2203h VIH VIH VIH VIH 2200h (M29DW641F) VIL VIL M29DW641F Table 5. Bus Operations Block Protection(1) Operation E G W RP VPP/WP Verify Extended Block indicator (bits DQ6, DQ7) Data Inputs/Outputs A21- A11A5- A3A9 A8 A7 A6 A1 A0 A12 A10 A4 A2 DQ15-DQ0 BA VIL VIL VIH VIH BKA (3) X X X VID X X X X VIH Verify Block Protection status Temporary Block Unprotect(4) Address Inputs VID X VIL VIH VIL VIL Valid VIL 0080h (Customer Lockable) VIH 00C0h (Customer Locked)(2) VIL 0001h (protected) 0000h (unprotected) Data Input 1. X = VIL or VIH. 2. This indicates the protection status of the second section of the Extended Block; the first section of the Extended Block being always Factory Locked. 3. BKA Bank Address, BA Any Address in the Block. 4. The RP pin unprotects all the blocks that have been previously protected using a High voltage Protection Technique. 19/80 Hardware Protection 4 M29DW641F Hardware Protection The M29DW641F features hardware Protection/Unprotection. Refer to Table 6 for details on Hardware Block Protection/unprotection using VPP/WP and RP pins. 4.1 Write Protect The VPP/WP pin protects the four outermost parameter blocks (refer to Section 2: Signal descriptions for a detailed description of the signals). 4.2 Temporary Block Unprotect When held at VID, the Reset/Block Temporary Unprotect pin, RP, will temporarily unprotect all the blocks previously protected using a High voltage Block Protection technique. Table 6. VPP/WP Hardware Protection(1) RP Function VIH 4 outermost parameter blocks protected from Program/Erase Operations VID All blocks temporarily unprotected except the 4 outermost blocks VIH or VID VID All blocks temporarily unprotected VPPH VIH or VID All blocks temporarily unprotected VIL 1. The temporary unprotection is valid only for the blocks that have been protected using the High voltage Protection Technique (see Appendix D: High voltage Block Protection). The blocks protected using a Software Protection method (Standard or Password) do not follow this rules. 20/80 M29DW641F 5 Software Protection Software Protection The M29DW641F has two different Software Protection modes: the Standard and Password Protection modes. On first use all parts default to the Standard Protection mode and the customer is free to activate the Standard or the Password Protection mode. The desired protection mode is activated by setting one of two one-time programmable bits, the Standard Protection mode Lock bit or the Password Protection mode Lock bit. Programming the Standard or the Password Protection mode Lock bit to ‘1’ will permanently activate the Standard or the Password Protection mode, respectively. These two bits are one-time programmable and non-volatile, once the Protection mode has been programmed, it cannot be changed and the device will permanently operate in the selected Protection mode. It is recommended to activate the desired Software Protection mode when first programming the device. The device is shipped with all blocks unprotected. The Block Protection status can be read by issuing the Auto Select command (see Table 7: Block Protection status). The Standard and Password Protection modes offer two levels of protection, a Block Lock/Unlock protection and a Non-volatile Protection. For the four outermost parameter blocks, an even higher level of block protection can be achieved by locking the blocks using the Non-volatile Protection and then by holding the VPP/WP pin Low. 5.1 Standard Protection mode 5.1.1 Block Lock/Unlock Protection It is a flexible mechanism to protect/unprotect a block or a group of blocks from Program or Erase Operations. A volatile Lock bit is assigned to each block or group of blocks. When the lock bit is set to ‘1’ the associated block or group of blocks is protected from Program/Erase Operations, when the Lock bit is set to ‘0’ the associated block or group of blocks is unprotected and can be programmed or erased. The Lock bits can be set (‘1’) and cleared (‘0’) individually as often as required by issuing a Set Lock bit command and Clear Lock bit command, respectively. After a Power-up or Hardware Reset, all the Lock bits are cleared to ‘0’ (block unlocked). The device is shipped with all the Lock bits set to ‘0’. 21/80 Software Protection 5.1.2 M29DW641F Non-volatile Protection A Non-Volatile Modify Protection bit is assigned to each block or group of blocks. When a Non-Volatile Modify Protection bit is set to ‘1’, the associated block or group of blocks is protected, preventing any Program or Erase Operations in this block or group of blocks. The Non-Volatile Modify Protection bits are set individually by issuing a Set Non-Volatile Modify Protection bit command. They are non-volatile and will remain set through a hardware reset or a power-down/power-up sequence. The Non-Volatile Modify Protection bits cannot be cleared individually, they can only be cleared all at the same time by issuing a Clear Non-Volatile Modify Protection bits command. The device features a volatile Lock-Down bit which can be used to prevent changing the state of the Non-Volatile Modify Protection bits. When set to ‘1’, the Non-Volatile Modify Protection bits can no longer be modified; when set to ‘0’, the Non-Volatile Modify Protection bits can be set and reset using the Set Non-Volatile Modify Protection bit command and the Clear Non-Volatile Modify Protection bits command, respectively. The Lock-Down bit is set by issuing the Set Lock-Down bit command. It is not cleared using a command, but through a hardware reset or a power-down/power-up sequence. The part is shipped with the Non-Volatile Modify Protection bits set to ‘0’. Locked blocks and Non-Volatile Locked blocks can co-exist in the same memory array. Refer to Table 7: Block Protection status and Figure 6: Software Protection scheme for details on the block protection mechanism. 5.2 Password Protection mode The Password Protection mode provides a more advanced level of software protection than the Standard Protection mode. Prior to entering the Password Protection mode, it is necessary to set a password and to verify it (see Section 6.3.5: Password Program command and Section 6.3.6: Password Verify command). The Password Protection mode is then activated by programming the Password Protection mode Lock bit to ‘1’. This operation is not reversible and once the bit is programmed the device will permanently remain in the Password Protection mode. The Password Protection mode uses the same protection mechanisms as the Standard Protection mode (Block Lock/Unlock, Non-volatile Protection). 5.2.1 Block Lock/Unlock Protection The Block Lock/Unlock Protection operates exactly in the same way as in the Standard Protection mode. 22/80 M29DW641F 5.2.2 Software Protection Non-volatile Protection The Non-Volatile Protection is more advanced in the Password Protection mode. In this mode, the Lock-Down bit is non-volatile and cannot be cleared through a hardware reset or a power-down/power-up sequence. The Lock-Down bit is cleared by issuing the Password Protection Unlock command along with the correct password. Once the correct Password has been provided, the Lock-Down bit is cleared and the Non-Volatile Modify Protection bits can be set or reset using the appropriate commands (the Set Non-Volatile Modify Protection bit command or the Clear Non-Volatile Modify Protection bits command, respectively). If the Password provided is not correct, the Lock-Down bit remains locked and the state of the NonVolatile Modify Protection bits cannot be modified. The Password is a 64-bit code located in the memory space. It must be programmed by the user prior to selecting the Password Protection mode. The Password is programmed by issuing a Password Program command and checked by issuing a Password Verify command. The Password should be unique for each part. Once the device is in Password Protection mode, the Password can no longer be read or retrieved. Moreover, all commands to the address where the password is stored, are disabled. Refer to Table 7 and Figure 6: Software Protection scheme for details on the block protection scheme. Table 7. Block Protection status Non-volatile Volatile Modify Protection Lock bit bit 0 0 Lock-Down bit Block Protection status 0 0000h 0 0 1 0 1 0 1 0 0 1 1 0 0 1 1 1 0 1 1 1 1 0001h Block Protection status Block Unprotected Block Program/Erase Protected Non-volatile Modify Protection bit can be modified(1) Non-volatile Modify Protection bit cannot be modified(1) Non-volatile Modify Protection bit can be modified(1) Non-volatile Modify Protection bit cannot be modified(1) 1. The Lock bit can always be modified by issuing a Clear Lock bit command or by taking the device through a Power-up or Hardware Reset. 23/80 Software Protection Figure 5. M29DW641F Block Protection state diagram Set Standard Protection Mode Default: Standard Protection Standard Protection Set Password Protection Mode Password Protection ai11503 Figure 6. Software Protection scheme Parameter Block or Up to 4 Main Blocks Lock bit Non-Volatile Modify Protection bit Lock-Down bit Standard Protection mode Block Lock/Unlock Protection Non-Volatile Protection Password Protection mode AI11504 24/80 M29DW641F 6 Command interface Command interface All Bus Write Operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write Operations. Failure to observe a valid sequence of Bus Write Operations will result in the memory returning to Read mode. The long command sequences are imposed to maximize data security. 6.1 Standard commands See Table 8: Standard commands for a summary of the Standard commands. 6.1.1 Read/Reset command The Read/Reset command returns the memory to Read mode. It also resets the errors in the Status Register. Either one or three Bus Write Operations can be used to issue the Read/Reset command. The Read/Reset command can be issued, between Bus Write cycles before the start of a Program or Erase Operation, to return the device to Read mode. If the Read/Reset command is issued during the time-out of a Block Erase Operation, the memory will take up to 10µs to abort. During the abort period no valid data can be read from the memory. The Read/Reset command will not abort an Erase Operation when issued while in Erase Suspend. 6.1.2 Auto Select command The Auto Select command is used to read the Manufacturer Code, the Device Code, the Protection status of each block (Block Protection status) and the Extended Block Protection indicator. It can be addressed to either Bank. Three consecutive Bus Write Operations are required to issue the Auto Select command. Once the Auto Select command is issued, Bus Read Operations to specific addresses output the Manufacturer Code, the Device Code, the Extended Block Protection indicator and a Block Protection status (see Table 8: Standard commands in relation with Table 4 and Table 5). The memory remains in Auto Select mode until a Read/Reset or CFI Query command is issued. 25/80 Command interface 6.1.3 M29DW641F Read CFI Query command The Read CFI Query command is used to put the addressed bank in Read CFI Query mode. Once in Read CFI Query mode, Bus Read Operations to the same bank will output data from the Common Flash Interface (CFI) Memory Area. If the Read Operations are to a different bank from the one specified in the command then the Read Operations will output the contents of the memory array and not the CFI data. One Bus Write cycle is required to issue the Read CFI Query command. Care must be taken to issue the command to one of the banks (A21-A19) along with the address shown in Table 3 Once the command is issued subsequent Bus Read Operations in the same bank (A21-A19) to the addresses shown in Appendix B (A7-A0), will read from the Common Flash Interface Memory Area. This command is valid only when the device is in the Read Array or Auto Select mode. To enter Read CFI query mode from Auto Select mode, the Read CFI Query command must be issued to the same bank address as the Auto Select command, otherwise the device will not enter Read CFI Query mode. The Read/Reset command must be issued to return the device to the previous mode (the Read Array mode or Auto Select mode). A second Read/Reset command is required to put the device in Read Array mode from Auto Select mode. See Appendix B, Table 29, Table 30, Table 31, Table 32, Table 33 and Table 34 for details on the information contained in the Common Flash Interface (CFI) memory area. 6.1.4 Chip Erase command The Chip Erase command can be used to erase the entire chip. Six Bus Write Operations are required to issue the Chip Erase command and start the Program/Erase Controller. If any blocks are protected, then these are ignored and all the other blocks are erased. If all of the blocks are protected the Chip Erase Operation appears to start but will terminate within about 100µs, leaving the data unchanged. No error condition is given when protected blocks are ignored. During the Erase Operation the memory will ignore all commands, including the Erase Suspend command. It is not possible to issue any command to abort the operation. Typical chip erase times are given in Table 12. All Bus Read Operations during the Chip Erase Operation will output the Status Register on the Data Inputs/Outputs. See the section on the Status Register for more details. After the Chip Erase Operation has completed the memory will return to the Read mode, unless an error has occurred. When an error occurs the memory will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode. The Chip Erase command sets all of the bits in unprotected blocks of the memory to ’1’. All previous data is lost. 26/80 M29DW641F 6.1.5 Command interface Block Erase command The Block Erase command can be used to erase a list of one or more blocks in one or more Banks. It sets all of the bits in the unprotected selected blocks to ’1’. All previous data in the selected blocks is lost. Six Bus Write Operations are required to select the first block in the list. Each additional block in the list can be selected by repeating the sixth Bus Write Operation using the address of the additional block. The Block Erase Operation starts the Program/Erase Controller after a time-out period of 50µs after the last Bus Write Operation. Once the Program/Erase Controller starts it is not possible to select any more blocks. Each additional block must therefore be selected within 50µs of the last block. The 50µs timer restarts when an additional block is selected. After the sixth Bus Write Operation a Bus Read Operation within the same Bank will output the Status Register. See the Status Register section for details on how to identify if the Program/Erase Controller has started the Block Erase Operation. If any selected blocks are protected then these are ignored and all the other selected blocks are erased. If all of the selected blocks are protected the Block Erase Operation appears to start but will terminate within about 100µs, leaving the data unchanged. No error condition is given when protected blocks are ignored. During the Block Erase Operation the memory will ignore all commands except the Erase Suspend command and the Read/Reset command which is only accepted during the 50µs time-out period. Typical block erase times are given in Table 12. After the Erase Operation has started all Bus Read Operations to the Banks being erased will output the Status Register on the Data Inputs/Outputs. See the section on the Status Register for more details. After the Block Erase Operation has completed the memory will return to the Read mode, unless an error has occurred. When an error occurs, Bus Read Operations to the Banks where the command was issued will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode. 6.1.6 Erase Suspend command The Erase Suspend command may be used to temporarily suspend a Block or multiple Block Erase Operation. One Bus Write Operation specifying the Bank Address of one of the Blocks being erased is required to issue the command. Issuing the Erase Suspend command returns the whole device to Read mode. The Program/Erase Controller will suspend within the Erase Suspend Latency time (see Table 12 for value) of the Erase Suspend command being issued. Once the Program/Erase Controller has stopped the memory will be set to Read mode and the Erase will be suspended. If the Erase Suspend command is issued during the period when the memory is waiting for an additional block (before the Program/Erase Controller starts) then the Erase is suspended immediately and will start immediately when the Erase Resume command is issued. It is not possible to select any further blocks to erase after the Erase Resume. During Erase Suspend it is possible to Read and Program cells in blocks that are not being erased; both Read and Program Operations behave as normal on these blocks. If any attempt is made to program in a protected block or in the suspended block then the Program command is ignored and the data remains unchanged. The Status Register is not read and 27/80 Command interface M29DW641F no error condition is given. Reading from blocks that are being erased will output the Status Register. It is also possible to issue the Auto Select, Read CFI Query and Unlock Bypass commands during an Erase Suspend. The Read/Reset command must be issued to return the device to Read Array mode before the Resume command will be accepted. During Erase Suspend a Bus Read Operation to the Extended Block will output the Extended Block data. Once in the Extended Block mode, the Exit Extended Block command must be issued before the Erase Operation can be resumed. 6.1.7 Erase Resume command The Erase Resume command is used to restart the Program/Erase Controller after an Erase Suspend. The command must include the Bank Address of the Erase-Suspended Bank, otherwise the Program/Erase Controller is not restarted. The device must be in Read Array mode before the Resume command will be accepted. An Erase can be suspended and resumed more than once. 6.1.8 Program Suspend command The Program Suspend command allows the system to interrupt a Program Operation so that data can be read from any block. When the Program Suspend command is issued during a Program Operation, the device suspends the Program Operation within the Program Suspend Latency time (see Table 12 for value) and updates the Status Register bits. The Bank Addresses of the Block being programmed must be specified in the Program Suspend command. After the Program Operation has been suspended, the system can read array data from any address. However, data read from Program-Suspended addresses is not valid. The Program Suspend command may also be issued during a Program Operation while an erase is suspended. In this case, data may be read from any addresses not in Erase Suspend or Program Suspend. If a read is needed from the Extended Block area (One-time Program area), the user must use the proper command sequences to enter and exit this region. The system may also issue the Auto Select command sequence when the device is in the Program Suspend mode. The system can read as many Auto Select codes as required. When the device exits the Auto Select mode, the device reverts to the Program Suspend mode, and is ready for another valid operation. See Auto Select command sequence for more information. 6.1.9 Program Resume command After the Program Resume command is issued, the device reverts to programming. The controller can determine the status of the Program Operation using the DQ7 or DQ6 status bits, just as in the standard Program Operation. See Write Operation status for more information. The system must write the Program Resume command, specifying the Bank addresses of the Program-Suspended Block, to exit the Program Suspend mode and to continue the Programming Operation. 28/80 M29DW641F Command interface Further issuing of the Resume command is ignored. Another Program Suspend command can be written after the device has resumed programming. 6.1.10 Program command The Program command can be used to program a value to one address in the memory array at a time. The command requires four Bus Write Operations, the final Write Operation latches the address and data in the internal state machine and starts the Program/Erase Controller. Programming can be suspended and then resumed by issuing a Program Suspend command and a Program Resume command, respectively (see Section 6.1.8: Program Suspend command and Section 6.1.9: Program Resume command). If the address falls in a protected block then the Program command is ignored, the data remains unchanged. The Status Register is never read and no error condition is given. After programming has started, Bus Read Operations in the Bank being programmed output the Status Register content, while Bus Read Operations to the other Bank output the contents of the memory array. See the section on the Status Register for more details. Typical program times are given in Table 12. After the Program Operation has completed the memory will return to the Read mode, unless an error has occurred. When an error occurs Bus Read Operations to the Bank where the command was issued will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode. One of the Erase commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’. 6.1.11 Verify command The Verify command is used to check if a block is blank or in other words, if it has been successfully erased and all its bits set to ’1’. It reads the value of the Error bit DQ5. If the Error bit is set to ’1’, it indicates that the operation failed. Three cycles are required to issue a Verify command: 1. The command starts with two unlock cycles. 2. The third Bus Write cycle sets up the Verify command code along with the address of the block to be checked. 29/80 Command interface Table 8. M29DW641F Standard commands Command Length Bus Operations(1)(2) 1st Add 2nd 3rd Data Add Data Add 4th 5th 6th Data Add Data Add Data Add Data 1 X F0 3 555 AA 2AA 55 X F0 3 555 AA 2AA 55 (BKA) 555 90 (3) (3) Program 4 555 AA 2AA 55 555 A0 PA PD Verify 3 555 AA 2AA 55 BA BC Chip Erase 6 555 AA 2AA 55 555 80 555 AA 2AA 55 555 10 Block Erase 6+ 555 AA 2AA 55 555 80 555 AA 2AA 55 BA 30 Erase/Program Suspend 1 BKA B0 Erase/Program Resume 1 BKA 30 Read CFI Query 1 (BKA) 555 98 Read/Reset Manufacturer code Device code Auto Select Extended Block Protection indicator Block Protection status 1. Grey cells represent Read cycles. The other cells are Write cycles. 2. X Don’t Care, PA Program Address, PD Program Data, BA Any address in the Block, BKA Bank Address. All values in the table are in hexadecimal. 3. The Auto Select addresses and data are given in Table 4: Read Electronic Signature, and Table 5: Block Protection, except for A9 that is ‘Don’t Care’. 30/80 M29DW641F 6.2 Command interface Fast Program commands The M29DW641F offers a set of Fast Program commands to improve the programming throughput: ● Double and Quadruple Word, Program ● Unlock Bypass When VPPH is applied to the VPP/Write Protect pin the memory automatically enters the Fast Program mode. The user can then choose to issue any of the Fast Program commands. Care must be taken because applying a VPPH to the VPP/WP pin will temporarily unprotect any protected block. Only one bank can be programmed at any one time. The other bank must be in Read mode or Erase Suspend. After programming has started, Bus Read Operations in the Bank being programmed output the Status Register content, while Bus Read Operations to the other Bank output the contents of the memory array. Fast Program commands can be suspended and then resumed by issuing a Program Suspend command and a Program Resume command, respectively (see Section 6.1.8: Program Suspend command and Section 6.1.9: Program Resume command). After the Fast Program command has completed, the memory will return to the Read mode, unless an error has occurred. When an error occurs Bus Read Operations to the Bank where the command was issued will continue to output the Status Register. A Read/Reset command must be issued to reset the error condition and return to Read mode. One of the Erase commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’. Typical Program times are given in Table 12: Program, Erase Times and Program, Erase Endurance cycles. See either Table 9: Fast Program commands, for a summary of the Fast Program commands. 6.2.1 Double Word Program command This is used to write two adjacent Words simultaneously. The addresses of the two Words must differ only in A0. Three bus write cycles are necessary to issue the command: 6.2.2 1. The first bus cycle sets up the command. 2. The second bus cycle latches the Address and the Data of the first Word to be written. 3. The third bus cycle latches the Address and the Data of the second Word to be written and starts the Program/Erase Controller. Quadruple Word Program command This is used to write four adjacent Words simultaneously. The addresses of the four Words must differ only in A1 and A0. Five bus write cycles are necessary to issue the command: 1. The first bus cycle sets up the command. 2. The second bus cycle latches the Address and the Data of the first Word to be written. 3. The third bus cycle latches the Address and the Data of the second Word to be written. 4. The fourth bus cycle latches the Address and the Data of the third Word to be written. 5. The fifth bus cycle latches the Address and the Data of the fourth Word to be written and starts the Program/Erase Controller. 31/80 Command interface 6.2.3 M29DW641F Unlock Bypass command The Unlock Bypass command is used in conjunction with the Unlock Bypass Program command to program the memory faster than with the standard program commands. When the cycle time to the device is long, considerable time saving can be made by using these commands. Three Bus Write Operations are required to issue the Unlock Bypass command. Once the Unlock Bypass command has been issued the bank enters Unlock Bypass mode. When in Unlock Bypass mode, only the Unlock Bypass Program and Unlock Bypass Reset commands are valid. The Unlock Bypass Program command can then be issued to program addresses within the bank, or the Unlock Bypass Reset command can be issued to return the bank to Read mode. In Unlock Bypass mode the memory can be read as if in Read mode. 6.2.4 Unlock Bypass Program command The Unlock Bypass Program command can be used to program one address in the memory array at a time. The command requires two Bus Write Operations, the final Write Operation latches the address and data and starts the Program/Erase Controller. The Program Operation using the Unlock Bypass Program command behaves identically to the Program Operation using the Program command. The operation cannot be aborted, a Bus Read Operation to the Bank where the command was issued outputs the Status Register. See the Program command for details on the behavior. 6.2.5 Unlock Bypass Reset command The Unlock Bypass Reset command can be used to return to Read/Reset mode from Unlock Bypass mode. Two Bus Write Operations are required to issue the Unlock Bypass Reset command. Read/Reset command does not exit from Unlock Bypass mode. Table 9. Fast Program commands Command(1) Length Bus Write Operations(2) 1st 2nd 3rd 4th 5th 6th Add Data Add Data Add Data Add Data Add Data Add Data Double Word Program 3 555 50 PA0 PD0 PA1 PD1 Quadruple Word Program 5 555 56 PA0 PD0 PA1 PD1 PA2 PD2 PA3 PD3 Unlock Bypass 3 555 AA 2AA 55 555 Unlock Bypass Program 2 X A0 PA PD Unlock Bypass Reset 2 X 90 X 00 20 1. The sequence consisting in 555 AA 2AA 55 X 25 is reserved and must not be issued. 2. X Don’t Care, PA Program Address, PD Program Data, BA Any address in the Block, BKA Bank Address, WBL Write Buffer Location. All values in the table are in hexadecimal. 32/80 M29DW641F 6.3 Command interface Block Protection commands Blocks or groups of blocks can be protected against accidental program, Erase or Read Operations. The Protection Groups are shown in Appendix A, Table 28: Block Addresses. The device block protection scheme is shown in Figure 6: Software Protection scheme and Figure 5: Block Protection state diagram. See Table 10: Block Protection commands, for a summary of the Block Protection commands. Only the commands related to the Extended Block Protection are available in both 8 bit and 16 bit memory configuration. The other block protection commands are available in 16-bit configuration only. 6.3.1 Enter Extended Block command The M29DW641F has one extra 128-Word block (Extended Block) that can only be accessed using the Enter Extended Block command. Three Bus Write cycles are required to issue the Extended Block command. Once the command has been issued the device enters Extended Block mode where all Bus Read or Program Operations to the Extended Block Addresses (see Table 28: Block Addresses). The Extended Block cannot be erased, and can be treated as one-time programmable (OTP) memory. In Extended Block mode only array cell locations (Bank A) with the same addresses as the Extended Block are not accessible. In Extended Block mode Dual Operations are allowed and the Extended Block physically belongs to Bank A. In Extended Block mode, Erase, Chip Erase, Erase Suspend and Erase resume commands are not allowed. To exit from the Extended Block mode the Exit Extended Block command must be issued. The Extended Block can be protected by setting the Extended Block Protection bit to ‘1’; however once protected the protection cannot be undone. 6.3.2 Exit Extended Block command The Exit Extended Block command is used to exit from the Extended Block mode and return the device to Read mode. Four Bus Write Operations are required to issue the command. 6.3.3 Set Extended Block Protection bit command The Set Extended Block Protection bit command programs the Extended Block Protection bit to ‘1’ thus preventing the second section of the Extended Block from being programmed. A Read/Reset command must be issued to abort a Set Extended Block Protection bit command. Six successive steps are required to issue the Set Extended Block Protection bit command. 1. The command starts with two unlock cycles. 2. The third Bus Write cycle sets up the Set Extended Block Protection bit command. 3. The last three cycles verify the value programmed at the Extended Block Protection bit address: if bit DQ0 of Data Inputs/Outputs is set to ’1’, it indicates that the Extended Block Protection bit has been successfully programmed. If DQ0 is ‘0’, the Set Extended Block Protection bit command must be issued and verified again. 33/80 Command interface 6.3.4 M29DW641F Verify Extended Block Protection bit command The Verify Extended Block Protection bit command reads the status of the Extended Block Protection bit on bit DQ0 of the Data Inputs/Outputs. If DQ0 is ‘1’, the second section of the Extended Block is protected from Program Operations. 6.3.5 Password Program command The Password Program command is used to program the 64-bit Password used in Password Protection mode. Four cycles are required to program the Password: 1. The first two cycles are unlock cycles. 2. The third cycle issues the Password Program command. 3. The fourth cycle inputs the 16-bit data required to program the Password. To program the 64-bit Password, the complete command sequence must be entered four times at four consecutive addresses selected by A1 to A0. Read Operations can be used to read the Status Register during a Password Program Operation. All other operations are forbidden. The Password can be checked by issuing a Password Verify command. Once Password Program Operation has completed, a Read/ Reset command must be issued to return the device to Read mode. The Password Protection mode can then be selected. By default, all Password bits are set to ‘1’. 6.3.6 Password Verify command The Password Verify command is used to verify the Password used in Password Protection mode. To verify the 64-bit Password, the complete command sequence must be entered four times at four consecutive addresses selected by A1 to A0. If this command is issued while the device is in Password Protection mode, it outputs ‘FFh’ and all Inputs/Outputs are high impedance. The Password is output regardless of the bank address. The user must issue a Read/reset command to return the device to Read mode. Dual Operations are not allowed during a Password Verify Operation. 34/80 M29DW641F 6.3.7 Command interface Password Protection Unlock command The Password Protection Unlock command is used to clear the Lock-Down bit in order to unprotect all Non-Volatile Modify Protection bits when the device is in Password Protection mode. The Password Protection Unlock command must be issued along with the correct Password. The complete command sequence must be entered for each 16 bits of the Password. There must be a 2µs delay between successive Password Protection Unlock commands in order to prevent hackers from cracking the Password by trying all possible 64-bit combinations. If this delay is not respected, the latest command will be ignored. 6.3.8 Set Password Protection mode command The Set Password Protection mode command puts the device in Password Protection mode by programming the Password Protection mode Lock bit to ‘1’. This command can be issued either with the Reset/Block Temporary Unprotect pin, RP, at VID or at VIH. Six cycles are required to issue a Set Password Protection mode command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the command. 3. The fourth and fifth cycles select the address (see Table 11: Protection command addresses). The last cycle verifies if the operation has been successful. If DQ0 is set to ’1’, the device has successfully entered the Password Protection mode. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. 4. There must be a 100µs delay between the fourth and fifth cycles. Once the Password Protection mode is activated the device will permanently remain in this mode. 6.3.9 Verify Password Protection mode command The Verify Password Protection mode command reads the status of the Password Protection mode Lock bit. If it is ‘1’, the device is in Password Protection mode. 6.3.10 Set Standard Protection mode command The Set Standard Protection mode command puts the device in Standard Protection mode by programming the Standard Protection mode Lock bit to ‘1’. Six cycles are required to issue the Standard Protection mode command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the program command. 3. The fourth and fifth cycles select the address (see Table 11: Protection command addresses). The last cycle verifies if the operation has been successful. If DQ0 is set to ’1’, the Standard Protection mode has been successfully activated. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. 4. There must be a 100µs delay between the fourth and fifth cycles. Once the Standard Protection mode is activated the device will permanently remain in this mode. 35/80 Command interface 6.3.11 M29DW641F Verify Standard Protection mode command The Verify Standard Protection mode command reads the status of the Standard Protection mode Lock bit. If it is ‘1’, the device is in Standard Protection mode. 6.3.12 Set Non-Volatile Modify Protection bit command A block or group of blocks can be protected from program or erase by issuing a Set NonVolatile Modify Protection bit command along with the block address. This command sets the Non-Volatile Modify Protection bit to ‘1’ for a given block or group of blocks. Six cycles are required to issue the command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the program command. 3. The fourth and fifth cycles select the address (see Table 11: Protection command addresses). The last cycle verifies if the operation has been successful. If DQ0 is set to ’1’, the NonVolatile Modify Protection bit has been successfully programmed. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. 4. There must be a 100µs delay between the fourth and fifth cycles. The Non-Volatile Modify Protection bits are erased simultaneously by issuing a Clear NonVolatile Modify Protection bits command except if the Lock-Down bit is set to ‘1’. The Non-Volatile Modify Protection bits can be set a maximum of 100 times. 6.3.13 Verify Non-volatile Modify Protection bit command The status of a Non-Volatile Modify Protection bit for a given block or group of blocks can be read by issuing a Verify Non-Volatile Modify Protection bit command along with the block address. 6.3.14 Clear Non-volatile Modify Protection bit command This command is used to clear all Non-Volatile Modify Protection bits. No specific block address is required. If the Lock-Down bit is set to ‘1’, the command will fail. Six cycles are required to issue a Clear Non-Volatile Modify Protection bits command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the command. 3. The last three cycles verify if the operation has been successful. If DQ0 is set to ’1’, all Non-Volatile Modify Protection bits have been successfully cleared. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. There must be a 12ms delay between the fourth and fifth cycles. 6.3.15 Set Lock bit command The Set Lock bit command individually sets the Lock bit to ‘1’ for a given block or group of blocks. If the Non-Volatile Lock bit for the same block or group of blocks is set, the block is locked regardless of the value of the Lock bit. (see Table 7: Block Protection status). 36/80 M29DW641F 6.3.16 Command interface Clear Lock bit command The Clear Lock bit command individually clears (sets to ‘0’) the Lock bit for a given block or group of blocks. If the Non-Volatile Lock bit for the same block or group of blocks is set, the block or group of blocks remains locked (see Table 7: Block Protection status). 6.3.17 Verify Lock bit command The status of a Lock bit for a given block can be read by issuing a Verify Lock bit command along with the block address. 6.3.18 Set Lock-Down bit command This command is used to set the Lock-Down bit to ‘1’ thus protecting the Non-Volatile Modify Protection bits from program and erase. There is no Unprotect Lock-Down bit command. 6.3.19 Verify Lock-Down bit command This command is used to read the status of the Lock-Down bit. The status is output on bit DQ1. If DQ1 is ‘1’, all the Non-Volatile Modify Protection bits are protected from Program or Erase Operations. 37/80 Command interface Table 10. M29DW641F Block Protection commands Command Length Bus Write Operations(1)(2)(3) 1st 2nd 3rd 4th Add Data Add Data Add Data Add 5th 6th Data Add Data Add Data OW 48 OW DQ0 RPW [1] PWA [2] RPW [2] PL 48 PL DQ0 (BA)/ NVMP DQ0 (BA)/ NVMP DQ0 Set Extended Block Protection bit(4) 6 555 AA 2AA 55 555 60 OW 68 Verify Extended Block Protection bit 4 555 AA 2AA 55 555 60 OW DQ0 Enter Extended Block 3 555 AA 2AA 55 555 88 Exit Extended Block 4 555 AA 2AA 55 555 90 X 00 Password Program(4) 4 555 AA 2AA 55 555 38 X [0-3] PW [0-3] Password Verify 4 555 AA 2AA 55 555 C8 PWA RPW [0-3] [0-3] Password Protection Unlock 7 555 AA 2AA 55 555 28 PWA RPW PWA [0] [0] [1] Set Password Protection mode(4)(5) 6 555 AA 2AA 55 555 60 PL 68 Verify Password Protection mode 4 555 AA 2AA 55 555 60 PL DQ0 6 555 AA 2AA 55 555 60 (BA)/ NVMP 68 (BA)/ NVMP 48 Verify NonVolatile Modify Protection bit 4 555 AA 2AA 55 555 60 (BA)/ NVMP 48 (BA)/ NVMP DQ0 Clear NonVolatile Modify Protection bits(6)(7) 6 555 AA 2AA 55 555 60 NVMP 60 (BA)/ NVMP 40 Set Lock-Down bit 3 555 AA 2AA 55 555 78 Verify LockDown bit 4 555 AA 2AA 55 555 58 BA DQ1 Set Lock bit 4 555 AA 2AA 55 555 48 BA X1h Clear Lock bit 4 555 AA 2AA 55 555 48 BA X0h Set NonVolatile Modify Protection bit (4)(5) 38/80 7th Add Data PW RPW [3] [3] M29DW641F Table 10. Command interface Block Protection commands (continued) Length Bus Write Operations(1)(2)(3) Command 1st 2nd 3rd 4th 5th Add Data Add Data Add Data Add Data Verify Lock bit 4 555 AA 2AA 55 555 58 BA DQ0 Set Standard Protection mode(5) 6 555 AA 2AA 55 555 60 SL 68 Verify Standard Protection mode(4) 4 555 AA 2AA 55 555 60 SL DQ0 6th 7th Add Data Add Data SL 48 SL DQ0 Add Data 1. The grey cell represent Read cycles. The other cells are Write cycles. 2. SA Protection Group Address, BA Any address in the Block, BKA Bank Address, SL Standard Protection mode Lock bit Address, PL Password Protection mode Lock Bit Address, PW Password Data, PWA Password Address, RPW Password Data Being Verified, NVMP Non-Volatile Modify Protection Bit Address, OW Extended Block Protection Bit Address, X Don’t Care. All values in the table are in hexadecimal. 3. Refer to Table 11: Protection command addresses for addresses. 4. A Reset command must be issued to return to the Read mode. 5. The 4th Bus Write cycle programs a protection bit (Extended Block Protection bit, Password, Standard Protection mode Lock bits, and a block NVMP bit). The 5th and 6th cycles verify that the bit has been successively programmed when DQ0=1. If DQ0=0 in the 6th cycle, the program command must be issued again and verified again. A 100µs delay is required between the 4th and the 5th cycle. 6. Cycle 4 erases all Non-Volatile Modify Protection bits. Cycles 5 and 6 verify that the bits have been successfully cleared when DQ0=0. If DQ0=1 in the 6th cycle, the erase command must be issued again and verified again. Before issuing the erase command, all Non-Volatile Modify Protection bits should be programmed to prevent over erasure. 7. A 12ms timeout is required between cycles 4 and 5. Table 11. Protection command addresses Bit Condition Address inputs A7-A0 Other Address Inputs RP at VIH 00001010 X RP at VID 10001010 X Standard Protection mode Lock bit Address (SL) 00010010 X Non-Volatile Modify Protection bit Address (NVMP) 00000010 Block Protection Group Address Extended Block Protection bit Address (OW) 00011010 X Password Protection mode Lock bit Address (PL) 39/80 Command interface Table 12. M29DW641F Program, Erase Times and Program, Erase Endurance cycles Parameter Min Chip Erase Block Erase (32 KWords) Typ(1)(2) Max(2) Unit 80 400(3) s 0.8 6 (4) µs 10 200(3) µs 40 200(3) s Chip Program (Double Word) 20 100 (3) s Chip Program (Quadruple Word) 10 50(3) s 4 µs Erase Suspend Latency Time Word Program Single or Multiple Word Program (1, 2 or 4 Words at-a-time) Chip Program (Word by Word) Program Suspend Latency Time Program/Erase cycles (per Block) Data Retention 100,000 Cycles 20 Years 1. Typical values measured at room temperature and nominal voltages. 2. Sampled, but not 100% tested. 3. Maximum value measured at worst case conditions for both temperature and VCC after 100,00 program/erase cycles. 4. Maximum value measured at worst case conditions for both temperature and VCC. 40/80 s 50(4) M29DW641F 7 Status Register Status Register The M29DW641F has one Status Register. The Status Register provides information on the current or previous Program or Erase Operations executed in each bank. The various bits convey information and errors on the operation. Bus Read Operations from any address within the Bank, always read the Status Register during Program and Erase Operations. It is also read during Erase Suspend when an address within a block being erased is accessed. The bits in the Status Register are summarized in Table 13: Status Register bits. 7.1 Data polling bit (DQ7) The Data Polling bit can be used to identify whether the Program/Erase Controller has successfully completed its operation or if it has responded to an Erase Suspend. The Data Polling bit is output on DQ7 when the Status Register is read. During Program Operations the Data Polling bit outputs the complement of the bit being programmed to DQ7. After successful completion of the Program Operation the memory returns to Read mode and Bus Read Operations from the address just programmed output DQ7, not its complement. During Erase Operations the Data Polling bit outputs ’0’, the complement of the erased state of DQ7. After successful completion of the Erase Operation the memory returns to Read mode. In Erase Suspend mode the Data Polling bit will output a ’1’ during a Bus Read Operation within a block being erased. The Data Polling bit will change from a ’0’ to a ’1’ when the Program/Erase Controller has suspended the Erase Operation. Figure 7: Data polling flowchart, gives an example of how to use the Data Polling bit. A Valid Address is the address being programmed or an address within the block being erased. 7.2 Toggle bit (DQ6) The Toggle bit can be used to identify whether the Program/Erase Controller has successfully completed its Operation or if it has responded to an Erase Suspend. The Toggle bit is output on DQ6 when the Status Register is read. During Program and Erase Operations the Toggle bit changes from ’0’ to ’1’ to ’0’, etc., with successive Bus Read Operations at any address. After successful completion of the operation the memory returns to Read mode. During Erase Suspend mode the Toggle bit will output when addressing a cell within a block being erased. The Toggle bit will stop toggling when the Program/Erase Controller has suspended the Erase Operation. Figure 8: Toggle flowchart, gives an example of how to use the Data Toggle bit. Figure 15 and Figure 16 describe Toggle bit timing waveform. 41/80 Status Register 7.3 M29DW641F Error bit (DQ5) The Error bit can be used to identify errors detected by the Program/Erase Controller. The Error bit is set to ’1’ when a Program, Block Erase or Chip Erase Operation fails to write the correct data to the memory. If the Error bit is set a Read/Reset command must be issued before other commands are issued. The Error bit is output on DQ5 when the Status Register is read. Note that the Program command cannot change a bit set to ’0’ back to ’1’ and attempting to do so will set DQ5 to ‘1’. A Bus Read Operation to that address will show the bit is still ‘0’. One of the Erase commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’. 7.4 Erase timer bit (DQ3) The Erase Timer bit can be used to identify the start of Program/Erase Controller Operation during a Block Erase command. Once the Program/Erase Controller starts erasing the Erase Timer bit is set to ’1’. Before the Program/Erase Controller starts the Erase Timer bit is set to ’0’ and additional blocks to be erased may be written to the Command Interface. The Erase Timer bit is output on DQ3 when the Status Register is read. 7.5 Alternative toggle bit (DQ2) The Alternative Toggle bit can be used to monitor the Program/Erase controller during Erase Operations. The Alternative Toggle bit is output on DQ2 when the Status Register is read. During Chip Erase and Block Erase Operations the Toggle bit changes from ’0’ to ’1’ to ’0’, etc., with successive Bus Read Operations from addresses within the blocks being erased. A protected block is treated the same as a block not being erased. Once the operation completes the memory returns to Read mode. During Erase Suspend the Alternative Toggle bit changes from ’0’ to ’1’ to ’0’, etc. with successive Bus Read Operations from addresses within the blocks being erased. Bus Read Operations to addresses within blocks not being erased will output the memory cell data as if in Read mode. After an Erase Operation that causes the Error bit to be set the Alternative Toggle bit can be used to identify which block or blocks have caused the error. The Alternative Toggle bit changes from ’0’ to ’1’ to ’0’, etc. with successive Bus Read Operations from addresses within blocks that have not erased correctly. The Alternative Toggle bit does not change if the addressed block has erased correctly. Figure 15 and Figure 16 describe Alternative Toggle bit timing waveform. 42/80 M29DW641F Status Register Table 13. Status Register bits(1) (2) Operation Address DQ7 DQ6 DQ5 DQ3 DQ2 RB Program Bank Address DQ7 Toggle 0 – – 0 Program During Erase Suspend Bank Address DQ7 Toggle 0 – – 0 Program Error Bank Address DQ7 Toggle 1 – – Hi-Z Chip Erase Any Address 0 Toggle 0 1 Toggle 0 Block Erase before timeout Erasing Block 0 Toggle 0 0 Toggle 0 Non-Erasing Block 0 Toggle 0 0 No Toggle 0 Erasing Block 0 Toggle 0 1 Toggle 0 Non-Erasing Block 0 Toggle 0 1 No Toggle 0 Erasing Block 1 No Toggle 0 – Toggle Hi-Z Block Erase Erase Suspend Non-Erasing Block Erase Error Data read as normal Hi-Z Good Block Address 0 Toggle 1 1 No Toggle Hi-Z Faulty Block Address 0 Toggle 1 1 Toggle Hi-Z 1. Unspecified data bits should be ignored. 2. Figure 15 and Figure 16 describe Toggle and Alternative Toggle bits timing waveforms. Figure 7. Data polling flowchart START READ DQ5 & DQ7 at VALID ADDRESS DQ7 = DATA YES NO NO DQ5 = 1 YES READ DQ7 at VALID ADDRESS DQ7 = DATA NO FAIL YES PASS AI07760 43/80 Status Register Figure 8. M29DW641F Toggle flowchart START READ DQ6 ADDRESS = BA READ DQ5 & DQ6 ADDRESS = BA DQ6 = TOGGLE NO YES NO DQ5 =1 YES READ DQ6 TWICE ADDRESS = BA DQ6 = TOGGLE NO YES FAIL PASS AI08929b 1. BA = Address of Bank being Programmed or Erased. 44/80 M29DW641F 8 Dual Operations and Multiple Bank architecture Dual Operations and Multiple Bank architecture The Multiple Bank architecture of the M29DW641F gives greater flexibility for software developers to split the code and data spaces within the memory array. The Dual Operations feature simplifies the software management of the device by allowing code to be executed from one bank while another bank is being programmed or erased. The Dual Operations feature means that while programming or erasing in one bank, Read Operations are possible in another bank with zero latency. Only one bank at a time is allowed to be in program or erase mode. However, certain commands can cross bank boundaries, which means that during an operation only the banks that are not concerned with the cross bank operation are available for Dual Operations. For example, if a Block Erase command is issued to erase blocks in both Bank A and Bank B, then only Banks C or D are available for read operations while the erase is being executed. If a Read Operation is required in a bank, which is programming or erasing, the Program or Erase Operation can be suspended. Also if the suspended operation was erase then a program command can be issued to another block, so the device can have one block in Erase Suspend mode, one programming and other banks in read mode. By using a combination of these features, Read Operations are possible at any moment. Figure 14 and Figure 15 show the Dual Operations possible in other banks and in the same bank. Note that only the commonly used commands are represented in these tables. Table 14. Dual Operations allowed in other banks Commands allowed in another bank(1) Status of bank(1) Read Array Read Program Program/ Read Auto CFI Program Erase /Erase Erase Status Select Suspend Resume Register(2) Query Idle Yes Yes(3) Yes Yes Yes Yes Yes(3) Yes(4) Programming Yes No No No – – No No Erasing Yes No No No – – No No Program Suspended Yes No Yes Yes No No – Yes(5) Erase Suspended Yes No Yes Yes Yes No – Yes(6) 1. If several banks are involved in a Program or Erase Operation, then only the banks that are not concerned with the operation are available for Dual Operations. 2. Read Status Register is not a command. The Status Register can be read during a block Program or Erase Operation. 3. Only after a program or Erase Operation in that bank. 4. Only after a Program or Erase Suspend command in that bank. 5. Only a Program Resume is allowed if the bank was previously in Program Suspend mode. 6. Only an Erase Resume is allowed if the bank was previously in Erase Suspend mode. 45/80 Dual Operations and Multiple Bank architecture Table 15. M29DW641F Dual Operations allowed in same bank Commands allowed in same bank Status of bank Read Array Read Read Program/ Program/ Auto CFI Status Program Erase Erase Erase Select Register(1) Query Suspend Resume Idle Yes Yes Yes Yes Yes Yes Yes(2) Yes(3) Programming No Yes No No – – Yes(4) – (5) – Erasing No Yes No No – No Yes Program Suspended Yes(6) No Yes Yes No – – Yes Erase Suspended Yes(6) Yes(7) Yes Yes Yes(6) No – Yes 1. Read Status Register is not a command. The Status Register can be read during a block Program or Erase Operation. 2. Only after a program or Erase Operation in that bank. 3. Only after a Program or Erase Suspend command in that bank. 4. Only a Program Suspend. 5. Only an Erase suspend. 6. Not allowed in the Block or Word that is being erased or programmed. 7. The Status Register can be read by addressing the block being erase suspended. 46/80 M29DW641F 9 Maximum ratings Maximum ratings Stressing the device above the rating listed in the Absolute Maximum Ratings table may cause permanent damage to the device. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Refer also to the Numonyx SURE Program and other relevant quality documents. Table 16. Absolute maximum ratings Symbol Parameter Min Max Unit TBIAS Temperature Under Bias –50 125 °C TSTG Storage Temperature –65 150 °C –0.6 VCC +0.6 V (1)(2) VIO Input or Output voltage VCC Supply voltage –0.6 4 V VID Identification voltage –0.6 13.5 V Program voltage –0.6 13.5 V VPP(3) 1. Minimum voltage may undershoot to –2V during transition and for less than 20ns during transitions. 2. Maximum voltage may overshoot to VCC +2V during transition and for less than 20ns during transitions. 3. VPP must not remain at 12V for more than a total of 80hrs. 47/80 DC and AC parameters 10 M29DW641F DC and AC parameters This section summarizes the operating measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC and AC characteristics Tables that follow, are derived from tests performed under the Measurement Conditions summarized in Table 17: Operating and AC measurement conditions. Designers should check that the operating conditions in their circuit match the operating conditions when relying on the quoted parameters. Table 17. Operating and AC measurement conditions 60 70 Parameter Unit Min Max Min Max VCC Supply voltage 2.7 3.6 2.7 3.6 V Ambient Operating Temperature –40 85 –40 85 °C Load Capacitance (CL) 30 Input Rise and Fall Times 10 Input Pulse voltages Input and Output Timing Ref. voltages Figure 9. 30 10 0 to VCC V VCC/2 VCC/2 V VCC VCC/2 0V AI05557 Figure 10. AC measurement load circuit VCC VCC 25kΩ DEVICE UNDER TEST CL 0.1µF 25kΩ 0.1µF CL includes JIG capacitance AI05558 48/80 ns 0 to VCC AC measurement I/O waveform VPP pF M29DW641F DC and AC parameters Table 18. Device capacitance Symbol CIN Parameter(1) Input capacitance COUT Output capacitance Test condition Min Max Unit VIN = 0V 6 pF VOUT = 0V 12 pF 1. Sampled only, not 100% tested. Table 19. DC characteristics Symbol Parameter Test condition Min Max Unit 0V ≤VIN ≤VCC ±1 µA ILI Input Leakage current ILO Output Leakage current 0V ≤VOUT ≤VCC ±1 µA Supply current (Read) E = VIL, G = VIH, f = 6MHz 10 mA Supply current (Standby) E = VCC ±0.2V, RP = VCC ±0.2V 100 µA VPP/WP = VIL or VIH 20 mA VPP/WP = VPPH 20 mA ICC1(1) ICC2 ICC3 (1)(2) Supply current (Program/Erase) Program/Erase Controller active VIL Input Low voltage –0.5 0.8 V VIH Input High voltage 0.7VCC VCC +0.3 V 11.5 12.5 V VPPH Voltage for Fast Program Acceleration VCC = 2.7V ±10% IPP Current for Fast Program Acceleration VCC =2.7V ±10% 15 mA VOL Output Low voltage IOL = 1.8mA 0.45 V VOH Output High voltage IOH = –100µA VID Identification voltage 11.5 12.5 V Program/Erase Lockout Supply voltage 1.8 2.3 V VLKO VCC –0.4 V 1. In Dual Operations the Supply current will be the sum of ICC1(read) and ICC3 (program/erase). 2. Sampled only, not 100% tested. 49/80 DC and AC parameters M29DW641F Figure 11. Random Read AC waveforms tAVAV A0-A21 VALID tAVQV tAXQX E tELQV tEHQX tELQX tEHQZ G tGLQX tGLQV DQ0-DQ15 tGHQX tGHQZ VALID AI05559b 50/80 DQ0-DQ15 G E tELQV tAVQV VALID tGLQV VALID tAVQV1 VALID A0-A2 VALID VALID A3-A21 VALID VALID VALID VALID VALID VALID VALID VALID VALID VALID tGHQZ tGHQX tEHQZ VALID VALID AI11267b tEHQX M29DW641F DC and AC parameters Figure 12. Page Read AC waveforms 51/80 DC and AC parameters Table 20. M29DW641F Read AC characteristics Symbol Alt Parameter Test condition 60 70 Unit tAVAV tRC Address Valid to Next Address Valid E = VIL, G = VIL Min 60 70 ns tAVQV tACC Address Valid to Output Valid E = VIL, G = VIL Max 60 70 ns tAVQV1 tPAGE Address Valid to Output Valid (Page) E = VIL, G = VIL Max 25 25 ns tELQX(1) tEHQZ(1) tLZ Chip Enable Low to Output Transition G = VIL Min 0 0 ns tHZ Chip Enable High to Output Hi-Z G = VIL Max 25 25 ns tELQV tCE Chip Enable Low to Output Valid G = VIL Max 60 70 ns tGLQX(1) tOLZ Output Enable Low to Output Transition E = VIL Min 0 0 ns tGLQV tOE Output Enable Low to Output Valid E = VIL Max 25 25 ns tGHQZ(1) tDF Output Enable High to Output Hi-Z E = VIL Max 25 25 ns tEHQX tGHQX tAXQX tOH Chip Enable, Output Enable or Address Transition to Output Transition Min 0 0 ns 1. Sampled only, not 100% tested. Figure 13. Write AC waveforms, Write Enable controlled tAVAV A0-A21 VALID tWLAX tAVWL tWHEH E tELWL tWHGL G tGHWL tWLWH W tWHWL tDVWH DQ0-DQ15 tWHDX VALID VCC tVCHEL RB tWHRL AI05560 52/80 M29DW641F Table 21. DC and AC parameters Write AC characteristics, Write Enable controlled Symbol Alt 60 70 Unit tAVAV tWC Address Valid to Next Address Valid Min 60 70 ns tAVWL tAS Address Valid to Write Enable Low Min 0 0 ns tDVWH tDS Input Valid to Write Enable High Min 45 45 ns tELWL tCS Chip Enable Low to Write Enable Low Min 0 0 ns Output Enable High to Write Enable Low Min 0 0 ns tGHWL Parameter tVCHEL tVCS VCC High to Chip Enable Low Min 50 50 µs tWLWH tWP Write Enable Low to Write Enable High Min 45 45 ns tWHDX tDH Write Enable High to Input Transition Min 0 0 ns tWHEH tCH Write Enable High to Chip Enable High Min 0 0 ns tWHWL tWPH Write Enable High to Write Enable Low Min 30 30 ns tWLAX tAH Write Enable Low to Address Transition Min 45 45 ns tWHGL tOEH Write Enable High to Output Enable Low Min 0 0 ns tWHRL(1) tBUSY Program/Erase Valid to RB Low Max 30 30 ns 1. Sampled only, not 100% tested. Figure 14. Write AC waveforms, Chip Enable controlled tAVAV VALID A0-A21 tELAX tAVEL tEHWH W tWLEL tEHGL G tGHEL tELEH E tEHEL tDVEH DQ0-DQ15 tEHDX VALID VCC tVCHWL RB tEHRL AI05561 53/80 DC and AC parameters Table 22. M29DW641F Write AC characteristics, Chip Enable controlled Symbol Alt 60 70 Unit tAVAV tWC Address Valid to Next Address Valid Min 60 70 ns tAVEL tAS Address Valid to Chip Enable Low Min 0 0 ns tDVEH tDS Input Valid to Chip Enable High Min 45 45 ns tELEH tCP Chip Enable Low to Chip Enable High Min 45 45 ns tEHDX tDH Chip Enable High to Input Transition Min 0 0 ns tEHWH tWH Chip Enable High to Write Enable High Min 0 0 ns tEHEL tCPH Chip Enable High to Chip Enable Low Min 30 30 ns tELAX tAH Chip Enable Low to Address Transition Min 45 45 ns tEHGL tOEH Chip Enable High to Output Enable Low Min 0 0 ns tEHRL(1) tBUSY Program/Erase Valid to RB Low Max 30 30 ns Output Enable High Chip Enable Low Min 0 0 ns tGHEL Parameter tVCHWL tVCS VCC High to Write Enable Low Min 50 50 µs tWLEL tWS Write Enable Low to Chip Enable Low Min 0 0 ns 1. Sampled only, not 100% tested. Figure 15. Toggle and alternative toggle bits mechanism, Chip Enable controlled Address Outside the Bank Being Programmed or Erased A0-A21 Address in the Bank Being Programmed or Erased Address Outside the Bank Being Programmed or Erased tAXEL E G tELQV tELQV DQ2(1)/DQ6(2) Data Read Operation outside the Bank Being Programmed or Erased Toggle/ Alternative Toggle Bit Toggle/ Alternative Toggle Bit Read Operation in the Bank Being Programmed or Erased Data Read Operation Outside the Bank Being Programmed or Erased AI11302 1. The Toggle bit is output on DQ6. 2. The Alternative Toggle bit is output on DQ2. 3. Refer to Table 20: Read AC characteristics for the value of tELQV. 54/80 M29DW641F DC and AC parameters Figure 16. Toggle and alternative toggle bits mechanism, Output Enable controlled Address Outside the Bank Being Programmed or Erased A0-A21 Address in the Bank Being Programmed or Erased Address Outside the Bank Being Programmed or Erased tAXGL G E tGLQV tGLQV Toggle/ Alternative Toggle Bit Data DQ2(1)/DQ6(2) Read Operation outside the Bank Being Programmed or Erased Toggle/ Alternative Toggle Bit Read Operation in the Bank Being Programmed or Erased Data Read Operation Outside the Bank Being Programmed or Erased AI11303 1. The Toggle bit is output on DQ6. 2. The Alternative Toggle bit is output on DQ2. 3. Refer to Table 20: Read AC characteristics for the value of tGLQV. Table 23. Symbol Toggle and alternative toggle bits AC characteristics Alt Parameter 60 70 Unit tAXEL Address Transition to Chip Enable Low Min 10 10 ns tAXGL Address Transition to Output Enable Low Min 10 10 ns Figure 17. Reset/Block Temporary Unprotect AC waveforms (no Program/Erase ongoing) RB E, G tPHEL, tPHGL RP tPLPX AI11300b 55/80 DC and AC parameters M29DW641F Figure 18. Reset/Block Temporary Unprotect during Program/Erase Operation AC waveforms W, E, G tPHWL, tPHEL, tPHGL RB tRHWL, tRHEL, tRHGL tPLPX RP tPHPHH tPLYH AI02931B Figure 19. Accelerated Program timing waveforms VPP VPP/WP VIL or VIH tVHVPP tVHVPP AI05563 56/80 M29DW641F DC and AC parameters Table 24. Reset/Block Temporary Unprotect AC characteristics Symbol Alt Parameter 60 70 Unit tPHEL, tPHWL, tPHGL(1) tRH RP High to Write Enable Low, Chip Enable Low, Output Enable Low Min 50 ns tRHEL, tRHWL tRHGL(1) tRB RB High to Write Enable Low, Chip Enable Low, Output Enable Low Min 0 ns tPLPX tRP RP Pulse Width Min 500 ns tPLYH(1) tREADY RP Low to Read mode, during Program or Erase Max 20 µs tPHPHH RP Rise Time to VID Min 500 ns tVHVPP VPP Rise and Fall Time Min 250 ns 1. Sampled only, not 100% tested. 57/80 Package mechanical data 11 M29DW641F Package mechanical data Figure 20. TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, package outline 1 48 e D1 B 24 L1 25 A2 E1 E A A1 DIE α L C CP TSOP-G 1. Drawing is not to scale. Table 25. TSOP48 – 48 lead Plastic Thin Small Outline, 12 x 20mm, package mechanical data millimeters inches Symbol Typ Min A Typ Min 1.200 Max 0.0472 A1 0.100 0.050 0.150 0.0039 0.0020 0.0059 A2 1.000 0.950 1.050 0.0394 0.0374 0.0413 B 0.220 0.170 0.270 0.0087 0.0067 0.0106 0.100 0.210 0.0039 0.0083 C CP 58/80 Max 0.100 0.0039 D1 12.000 11.900 12.100 0.4724 0.4685 0.4764 E 20.000 19.800 20.200 0.7874 0.7795 0.7953 E1 18.400 18.300 18.500 0.7244 0.7205 0.7283 e 0.500 – – 0.0197 – – L 0.600 0.500 0.700 0.0236 0.0197 0.0276 L1 0.800 α 3 0 5 0.0315 0 5 3 M29DW641F Package mechanical data Figure 21. TFBGA48 6x8mm - 6x8 Active Ball Array, 0.8mm pitch, package outline D D1 FD FE SD SE E E1 BALL "A1" ddd e e b A A2 A1 BGA-Z32 1. Drawing is not to scale. Table 26. TFBGA48 6x8mm - 6x8 Active Ball Array, 0.8mm pitch, package mechanical data millimeters inches Symbol Typ Min A Max Typ Min 1.200 A1 0.0472 0.260 A2 0.0102 0.900 b Max 0.350 0.450 0.0354 0.0138 0.0177 D 6.000 5.900 6.100 0.2362 0.2323 0.2402 D1 4.000 – – 0.1575 – – ddd 0.100 0.0039 E 8.000 7.900 8.100 0.3150 0.3110 0.3189 E1 5.600 – – 0.2205 – – e 0.800 – – 0.0315 – – FD 1.000 – – 0.0394 – – FE 1.200 – – 0.0472 – – SD 0.400 – – 0.0157 – – SE 0.400 – – 0.0157 – – 59/80 Part numbering 12 M29DW641F Part numbering Table 27. Ordering information scheme Example: M29DW641F 70 N 1 T Device type M29 Architecture D = Dual or Multiple Bank Operating voltage W = VCC = 2.7 to 3.6V Device function 641F = 64 Mbit (x16), Multiple Bank, Page, Boot Block, 8+24+24+8 partitioning, Flash Memory Speed 60 = 60ns 70 = 70ns Package N = TSOP48, 12 x 20 mm ZE = TFBGA48 6 x 8mm, 0.8mm pitch Temperature range 1 = 0 to 70 °C 6 = –40 to 85 °C Option Blank = Standard Packing T = Tape & Reel Packing E = ECOPACK Package, Standard Packing F = ECOPACK Package, Tape & Reel 24mm Packing Note: This product is also available with the Extended Block factory locked. For further details and ordering information contact your nearest Numonyx sales office. The device is shipped from the factory with the memory content bits erased to ’1’. For a list of available options (Speed, Package, etc.) or for further information on any aspect of this device, please contact your nearest Numonyx Sales Office. 60/80 M29DW641F Block addresses Appendix A Block addresses Bank A Bank Table 28. Block Addresses Block Block size (KWords) Protection Block Group Addresses 0 4 Protection Group 000000h–000FFFh(1) 1 4 Protection Group 001000h–001FFFh(1) 2 4 Protection Group 002000h–002FFFh(1) 3 4 Protection Group 003000h–003FFFh((1) 4 4 Protection Group 004000h–004FFFh(1) 5 4 Protection Group 005000h–005FFFh(1) 6 4 Protection Group 006000h–006FFFh(1) 7 4 Protection Group 007000h–007FFFh(1) 8 32 Protection Group 008000h–00FFFFh 9 32 Protection Group 010000h–017FFFh 10 32 Protection Group 018000h–01FFFFh 11 32 12 32 020000h–027FFFh 028000h–02FFFFh Protection Group 13 32 030000h–037FFFh 14 32 038000h–03FFFFh 15 32 040000h–047FFFh 16 32 048000h–04FFFFh Protection Group 17 32 050000h–057FFFh 18 32 058000h–05FFFFh 19 32 060000h–067FFFh 20 32 068000h–06FFFFh Protection Group 21 32 070000h–077FFFh 22 32 078000h–07FFFFh 61/80 Block addresses M29DW641F Bank Table 28. Block Addresses (continued) Block Block size (KWords) 23 32 24 32 Protection Block Group Addresses 080000h–087FFFh 088000h–08FFFFh Protection Group 25 32 090000h–097FFFh 26 32 098000h–09FFFFh 27 32 0A0000h–0A7FFFh 28 32 0A8000h–0AFFFFh Protection Group 29 32 0B0000h–0B7FFFh 30 32 0B8000h–0BFFFFh 31 32 0C0000h–0C7FFFh 32 32 0C8000h–0CFFFFh Protection Group 33 32 0D0000h–0D7FFFh 34 32 0D8000h–0DFFFFh 35 32 0E0000h–0E7FFFh 36 32 0E8000h–0EFFFFh Bank B Protection Group 37 32 0F0000h–0F7FFFh 38 32 0F8000h–0FFFFFh 39 32 100000h–107FFFh 40 32 108000h–10FFFFh Protection Group 41 32 110000h–117FFFh 42 32 118000h–11FFFFh 43 32 120000h–127FFFh 44 32 128000h–12FFFFh Protection Group 45 32 130000h–137FFFh 46 32 138000h–13FFFFh 47 32 140000h–147FFFh 48 32 148000h–14FFFFh Protection Group 49 32 150000h–157FFFh 50 32 158000h–15FFFFh 51 32 160000h–167FFFh 52 32 168000h–16FFFFh Protection Group 62/80 53 32 170000h–177FFFh 54 32 178000h–17FFFFh M29DW641F Block addresses Bank Table 28. Block Addresses (continued) Block Block size (KWords) 55 32 56 32 Protection Block Group Addresses 180000h–187FFFh 188000h–18FFFFh Protection Group 57 32 190000h–197FFFh 58 32 198000h–19FFFFh 59 32 1A0000h–1A7FFFh 60 32 1A8000h–1AFFFFh Bank B Protection Group 61 32 1B0000h–1B7FFFh 62 32 1B8000h–1BFFFFh 63 32 1C0000h–1C7FFFh 64 32 1C8000h–1CFFFFh Protection Group 65 32 1D0000h–1D7FFFh 66 32 1D8000h–1DFFFFh 67 32 1E0000h–1E7FFFh 68 32 1E8000h–1EFFFFh Protection Group 69 32 1F0000h–1F7FFFh 70 32 1F8000h–1FFFFFh 71 32 200000h–207FFFh 72 32 208000h–20FFFFh Protection Group 73 32 210000h–217FFFh 74 32 218000h–21FFFFh 75 32 220000h–227FFFh 76 32 228000h–22FFFFh Bank C Protection Group 77 32 230000h–237FFFh 78 32 238000h–23FFFFh 79 32 240000h–247FFFh 80 32 248000h–24FFFFh Protection Group 81 32 250000h–257FFFh 82 32 258000h–25FFFFh 83 32 260000h–267FFFh 84 32 268000h–26FFFFh Protection Group 85 32 270000h–277FFFh 86 32 278000h–27FFFFh 63/80 Block addresses M29DW641F Bank Table 28. Block Addresses (continued) Block Block size (KWords) 87 32 88 32 Protection Block Group Addresses 280000h–287FFFh 288000h–28FFFFh Protection Group 89 32 290000h–297FFFh 90 32 298000h–29FFFFh 91 32 2A0000h–2A7FFFh 92 32 2A8000h–2AFFFFh Protection Group 93 32 2B0000h–2B7FFFh 94 32 2B8000h–2BFFFFh 95 32 2C0000h–2C7FFFh 96 32 2C8000h–2CFFFFh Protection Group 97 32 2D0000h–2D7FFFh 98 32 2D8000h–2DFFFFh 99 32 2E0000h–2E7FFFh 100 32 2E8000h–2EFFFFh Bank C Protection Group 101 32 2F0000h–2F7FFFh 102 32 2F8000h–2FFFFFh 103 32 300000h–307FFFh 104 32 308000h–30FFFFh Protection Group 105 32 310000h–317FFFh 106 32 318000h–31FFFFh 107 32 320000h–327FFFh 108 32 328000h–32FFFFh Protection Group 109 32 330000h–337FFFh 110 32 338000h–33FFFFh 111 32 340000h–347FFFh 112 32 348000h–34FFFFh Protection Group 113 32 350000h–357FFFh 114 32 358000h–35FFFFh 115 32 360000h–367FFFh 116 32 368000h–36FFFFh Protection Group 64/80 117 32 370000h–377FFFh 118 32 378000h–37FFFFh M29DW641F Block addresses Bank Table 28. Block Addresses (continued) Block Block size (KWords) 119 32 120 32 Protection Block Group Addresses 380000h–387FFFh 388000h–38FFFFh Protection Group 121 32 390000h–397FFFh 122 32 398000h–39FFFFh 123 32 3A0000h–3A7FFFh 124 32 3A8000h–3AFFFFh Protection Group 125 32 3B0000h–3B7FFFh 126 32 3B8000h–3BFFFFh 127 32 3C0000h–3C7FFFh 128 32 3C8000h–3CFFFFh Bank D Protection Group 129 32 3D0000h–3D7FFFh 130 32 3D8000h–3DFFFFh 131 32 Protection Group 3E0000h–3E7FFFh 132 32 Protection Group 3E8000h–3EFFFFh 133 32 Protection Group 3F0000h–3F7FFFh 134 4 Protection Group 3F8000h–3F8FFFh 135 4 Protection Group 3F9000h–3F9FFFh 136 4 Protection Group 3FA000h–3FAFFFh 137 4 Protection Group 3FB000h–3FBFFFh 138 4 Protection Group 3FC000h–3FCFFFh 139 4 Protection Group 3FD000h–3FDFFFh 140 4 Protection Group 3FE000h–3FEFFFh 141 4 Protection Group 3FF000h–3FFFFFh 1. Used as the Extended Block Addresses in Extended Block mode. 65/80 Common Flash Interface (CFI) Appendix B M29DW641F Common Flash Interface (CFI) The Common Flash Interface is a JEDEC approved, standardized data structure that can be read from the Flash memory device. It allows a system software to query the device to determine various electrical and timing parameters, density information and functions supported by the memory. The system can interface easily with the device, enabling the software to upgrade itself when necessary. When the Read CFI Query command is issued the addressed bank enters Read CFI Query mode and Read Operations in the same bank (A21-A19) output the CFI data. Table 29, Table 30, Table 31, Table 32, Table 33 and Table 34 show the addresses (A0-A10) used to retrieve the data. The CFI data structure also contains a security area where a 64 bit unique security number is written (see Table 34: Security Code Area). This area can be accessed only in Read mode by the final user. It is impossible to change the security number after it has been written by Numonyx. Table 29. Query structure overview Address Sub-section name Description 10h CFI Query Identification String Command set ID and algorithm data offset 1Bh System Interface Information Device timing & voltage information 27h Device Geometry Definition Flash device layout 40h Primary Algorithm-specific Extended Query table Additional information specific to the Primary Algorithm (optional) 61h Security Code Area 64 bit unique device number 1. Query data are always presented on the lowest order data outputs. Table 30. CFI Query Identification String Address Data 10h 0051h 11h 0052h 12h 0059h 13h 0002h 14h 0000h 15h 0040h 16h 0000h 17h 0000h 18h Description Value “Q” Query Unique ASCII String "QRY" "R" "Y" Primary Algorithm Command Set and Control Interface ID code 16 bit ID code defining a specific algorithm AMD Compatible Address for Primary Algorithm extended Query table (see Table 33) P = 40h Alternate Vendor Command Set and Control Interface ID Code second vendor - specified algorithm supported NA 0000h 19h 0000h Address for Alternate Algorithm extended Query table 1Ah 0000h NA 1. Query data are always presented on the lowest order data outputs (DQ7-DQ0) only. DQ8-DQ15 are ‘0’. 66/80 M29DW641F Common Flash Interface (CFI) Table 31. CFI Query System Interface Information Address Data 1Bh 0027h VCC Logic Supply Minimum Program/Erase voltage bit 7 to 4BCD value in volts bit 3 to 0BCD value in 100 mV 2.7V 1Ch 0036h VCC Logic Supply Maximum Program/Erase voltage bit 7 to 4BCD value in volts bit 3 to 0BCD value in 100 mV 3.6V 1Dh 00B5h VPP [Programming] Supply Minimum Program/Erase voltage bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV 11.5V 1Eh 00C5h VPP [Programming] Supply Maximum Program/Erase voltage bit 7 to 4HEX value in volts bit 3 to 0BCD value in 100 mV 12.5V 1Fh 0004h Typical timeout per single byte/Word program = 2n µs 16µs 20h 0000h Description Typical timeout for minimum size write buffer program = 21h 000Ah Typical timeout per individual block erase = 22h 0000h Typical timeout for full Chip Erase = 2n ms 23h 24h 0004h 0000h Value Maximum timeout for byte/Word program = 2n 2n µs ms NA 1s NA 2n Maximum timeout for write buffer program = times typical 2n times typical 2n 25h 0003h Maximum timeout per individual block erase = 26h 0000h Maximum timeout for Chip Erase = 2n times typical times typical 256 µs NA 8s NA 67/80 Common Flash Interface (CFI) Table 32. M29DW641F Device Geometry Definition Address Data Description 27h 0017h Device Size = 2n in number of bytes 28h 29h 0002h 0000h Flash Device Interface Code description 2Ah 2Bh 0003h 0000h Maximum number of bytes in multi-byte program or page = 2n 8 2Ch 0003h Number of Erase Block Regions(1). It specifies the number of regions containing contiguous Erase Blocks of the same size. 3 2Dh 2Eh 0007h 0000h Erase Block Region 1 Information Number of Erase Blocks of identical size = 0007h+1 8 2Fh 30h 0020h 0000h Erase Block Region 1 Information Block size in Region 1 = 0020h * 256 byte 31h 32h 007Dh 0000h Erase Block Region 2 Information Number of Erase Blocks of identical size = 007Dh+1 33h 34h 0000h 0001h Erase Block Region 2 Information Block size in Region 2 = 0100h * 256 byte 35h 36h 0007h 0000h Erase Block Region 3 information Number of Erase Blocks of identical size = 0007h + 1 37h 38h 0020h 0000h Erase Block Region 3 information Block size in region 3 = 0020h * 256 bytes 39h 3Ah 3Bh 3Ch 0000h 0000h 0000h 0000h Erase Block Region 4 information Value 8 Mbytes x16 Async. 8 Kbytes 126 64 Kbytes 8 8 Kbytes 0 1. Erase Block Region 1 corresponds to addresses 000000h to 007FFFh; Erase block Region 2 corresponds to addresses 008000h to 3F7FFFh and Erase Block Region 3 corresponds to addresses 3F8000h to 3FFFFFh. 68/80 M29DW641F Common Flash Interface (CFI) Table 33. Primary Algorithm-specific extended Query table Address Data Description Value 40h 0050h 41h 0052h 42h 0049h 43h 0031h Major version number, ASCII "1" 44h 0033h Minor version number, ASCII "3" 45h 0000h Address Sensitive Unlock (bits 1 to 0) 00 = required, 01= not required Silicon Revision Number (bits 7 to 2) Yes 46h 0002h Erase Suspend 00 = not supported, 01 = Read only, 02 = Read and Write 2 47h 0001h Block Protection 00 = not supported, x = number of sectors in per group 1 48h 0001h Temporary Block Unprotect 00 = not supported, 01 = supported 49h 0007h Block Protect /Unprotect 07 = M29DW641F 4Ah 0077h Simultaneous Operations, x = number of blocks (excluding Bank A) 119 4Bh 0000h Burst mode, 00 = not supported, 01 = supported No 4Ch 0002h Page mode, 00 = not supported, 01 = 4 page Word, 02 = 8 page Word Yes 4Dh 00B5h VPP Supply Minimum Program/Erase voltage bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 mV 11.5V 4Eh 00C5h VPP Supply Maximum Program/Erase voltage bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 mV 12.5V 4Fh 0001h Top/Bottom Boot Block Flag 00h = uniform device 01h = 8 x8 Kbyte Blocks, Top and Bottom Boot with Write Protect 02h = Bottom boot device 03h = Top Boot Device 04h = Both Top and Bottom T/B 50h 0001h Program Suspend, 00 = not supported, 01 = supported Yes 57h 0004h Bank Organization, 00 = data at 4Ah is zero X = number of banks 4 58h 0017h Bank A information X = number of blocks in Bank A 23 59h 0030h Bank B information X = number of blocks in Bank B 48 "P" Primary Algorithm extended Query table unique ASCII string “PRI” "R" "I" Yes 7 69/80 Common Flash Interface (CFI) Table 33. M29DW641F Primary Algorithm-specific extended Query table (continued) Address Data 5Ah 0030h Bank C information X = number of blocks in Bank C 48 5Bh 0017h Bank D information X = number of blocks in Bank D 23 Table 34. Description Security Code Area Address Data 61h XXXX 62h XXXX 63h XXXX 64h XXXX Description 64 bit: unique device number 70/80 Value M29DW641F Extended Memory Block Appendix C Extended Memory Block The M29DW641F has an extra block, the Extended Block, that can be accessed using a dedicated command. This Extended Block is 128 Words. It is used as a security block (to provide a permanent security identification number) or to store additional information. The Extended Block is divided into two memory areas of 64 Words each: ● The first one is Factory Locked. ● The second one is Customer Lockable. It is up to the customer to protect it from Program Operations. Its status is indicated by bit DQ6 and DQ7. When DQ7 is set to ‘1’ and DQ6 to ‘0’, it indicates that this second memory area is Customer Lockable. When DQ7 and DQ6 are both set to ‘1’, it indicates that the second part of the Extended Block is Customer Locked and protected from Program Operations. Bit DQ7 being permanently locked to either ‘1’ or ‘0’ is another security feature which ensures that a customer lockable device cannot be used instead of a factory locked one. Bits DQ6 and DQ7 are the most significant bits in the Extended Block Protection indicator and a specific procedure must be followed to read it. See Section 3.6.2: Verify Extended Block Protection indicator” in Table 5: Block Protection, for details of how to read bit DQ7. The Extended Block can only be accessed when the device is in Extended Block mode. For details of how the Extended Block mode is entered and exited, refer to the Section 6.1.10: Program command and Section 6.3.2: Exit Extended Block command, and to Table 10: Block Protection commands. C.1 Factory Locked section of the Extended Block The first section of The Extended Block is permanently protected from Program Operations and cannot be unprotected. The Random Number, Electronic Serial Number (ESN) and Security Identification Number (see Table 35: Extended Block Address and Data) are written in this section in the factory. 71/80 Extended Memory Block C.2 M29DW641F Customer Lockable section of the Extended Block The device is delivered with the second section of the Extended Block "Customer Lockable": bits DQ7 and DQ6 are set to '1' and '0' respectively. It is up to the customer to program and protect this section of the Extended Block but care must be taken because the protection is not reversible. There are three ways of protecting this section: ● Issue the Enter Extended Block command to place the device in Extended Block mode, then use the In-System Technique with RP either at VIH or at VID. Refer to Section D.2: In-system technique in Appendix D: High voltage Block Protection, and to the corresponding flowcharts Figure 24 and Figure 25 for a detailed explanation of the technique). ● Issue the Enter Extended Block command to place the device in Extended Block mode, then use the Programmer Technique. Refer to Section D.1: Programmer technique in Appendix D: High voltage Block Protection, and to the corresponding flowcharts Figure 22 and Figure 23 for a detailed explanation of the technique). ● Issue a Set Extended Block Protection bit command to program the Extended Block Protection bit to ‘1’ thus preventing the second section of the Extended Block from being programmed. Bit DQ6 of the Extended Block Protection indicator is automatically set to '1' to indicate that the second section of the Extended Block is Customer Locked. Once the Extended Block is programmed and protected, the Exit Extended Block command must be issued to exit the Extended Block mode and return the device to Read mode. Table 35. Extended Block Address and Data Data Device Address(1) Factory Locked Customer Lockable 000000h-00003Fh Random Number, Security Identification Number, ESN(2) Unavailable 000040h-00007Fh Unavailable Determined by Customer M29DW641F 1. See Table 28: Block Addresses. 2. ENS = Electronic Serial Number. 72/80 M29DW641F Appendix D High voltage Block Protection High voltage Block Protection he High voltage Block Protection can be used to prevent any operation from modifying the data stored in the memory. The blocks are protected in groups, refer to Appendix A, Table 28: Block Addresses for details of the Protection Groups. Once protected, Program and Erase Operations within the protected group fail to change the data. There are three techniques that can be used to control Block Protection, these are the Programmer technique, the In-System technique and Temporary Unprotection. Temporary Unprotection is controlled by the Reset/Block Temporary Unprotection pin, RP; this is described in the Signal Descriptions section. To protect the Extended Block issue the Enter Extended Block command and then use either the Programmer or In-System technique. Once protected issue the Exit Extended Block command to return to read mode. The Extended Block protection is irreversible, once protected the protection cannot be undone. D.1 Programmer technique The Programmer technique uses high (VID) voltage levels on some of the bus pins. These cannot be achieved using a standard microprocessor bus, therefore the technique is recommended only for use in Programming Equipment. To protect a group of blocks follow the flowchart in Figure 22: Programmer equipment Group Protect flowchart. To unprotect the whole chip it is necessary to protect all of the groups first, then all groups can be unprotected at the same time. To unprotect the chip follow Figure 23: Programmer equipment Chip Unprotect flowchart. Figure 36: Programmer technique Bus Operations, 8-bit or 16-bit mode, gives a summary of each operation. The timing on these flowcharts is critical. Care should be taken to ensure that, where a pause is specified, it is followed as closely as possible. Do not abort the procedure before reaching the end. Chip Unprotect can take several seconds and a user message should be provided to show that the operation is progressing. D.2 In-system technique The In-System technique requires a high voltage level on the Reset/Blocks Temporary Unprotect pin, RP (1). This can be achieved without violating the maximum ratings of the components on the microprocessor bus, therefore this technique is suitable for use after the memory has been fitted to the system. To protect a group of blocks follow the flowchart in Figure 24: In-System equipment Group Protect flowchart. To unprotect the whole chip it is necessary to protect all of the groups first, then all the groups can be unprotected at the same time. To unprotect the chip follow Figure 25: In-System equipment Chip Unprotect flowchart. The timing on these flowcharts is critical. Care should be taken to ensure that, where a pause is specified, it is followed as closely as possible. Do not allow the microprocessor to service interrupts that will upset the timing and do not abort the procedure before reaching the end. Chip Unprotect can take several seconds and a user message should be provided to show that the operation is progressing. Note: RP can be either at VIH or at VID when using the In-System Technique to protect the Extended Block. 73/80 High voltage Block Protection Table 36. M29DW641F Programmer technique Bus Operations, 8-bit or 16-bit mode E G W Address Inputs A0-A21 Data Inputs/Outputs DQ15-DQ0 Block (Group) Protect(1) VIL VID VIL Pulse A9 = VID, A12-A21 Block Address Others = X X Chip Unprotect VID VID VIL Pulse A6 = VIH, A9 = VID, A12 = VIH, A15 = VIH Others =X X Block (Group) Protect Verify VIL VIL VIH A0 = VIL, A1 = VIH, A2 = VIL, A3 = VIL, A6 = VIL, A9 = VID, A12- 21 Block Address, Others = X Pass = xx01h Retry = xx00h. VIH A0 = VIL, A1 = VIH, A2 = VIL, A3 = VIL, A6 = VIH, A9 = VID, A12-A21 Block Address Others = X Pass = xx00h Retry = xx01h. Operation Block (Group) Unprotect Verify VIL VIL 1. Block Protection Groups are shown in Appendix D, Table 28. 74/80 M29DW641F High voltage Block Protection Figure 22. Programmer equipment Group Protect flowchart START Set-up ADDRESS = GROUP ADDRESS W = VIH n=0 G, A9 = VID, E = VIL Wait 4µs Protect W = VIL Wait 100µs W = VIH E, G = VIH, A1 = VIH A0, A2, A3, A6 = VIL E = VIL Verify Wait 4µs G = VIL Wait 60ns Read DATA DATA = 01h NO End YES ++n = 25 NO YES A9 = VIH E, G = VIH A9 = VIH E, G = VIH PASS FAIL AI07756 1. Block Protection Groups are shown in Appendix D, Table 28. 75/80 High voltage Block Protection M29DW641F Figure 23. Programmer equipment Chip Unprotect flowchart START Set-up PROTECT ALL GROUPS n=0 CURRENT GROUP = 0 A6, A12, A15 = VIH(1) E, G, A9 = VID Wait 4µs Unprotect W = VIL Wait 10ms W = VIH E, G = VIH ADDRESS = CURRENT GROUP ADDRESS A0, A2, A3 = VIL A1, A6 = VIH E = VIL Wait 4µs INCREMENT CURRENT GROUP Verify G = VIL Wait 60ns Read DATA NO NO DATA = 00h ++n = 1000 YES LAST GROUP End YES A9 = VIH E, G = VIH FAIL NO YES A9 = VIH E, G = VIH PASS AI07757 1. Block Protection Groups are shown in Appendix D, Table 28. 76/80 M29DW641F High voltage Block Protection Figure 24. In-System equipment Group Protect flowchart Set-up START n=0 RP = VID Protect WRITE 60h ADDRESS = GROUP ADDRESS A0, A2, A3, A6 = VIL, A1 = VIH WRITE 60h ADDRESS = GROUP ADDRESS A0, A2, A3, A6 = VIL, A1 = VIH Wait 100µs Verify WRITE 40h ADDRESS = GROUP ADDRESS A0, A2, A3, A6 = VIL, A1 = VIH Wait 4µs READ DATA ADDRESS = GROUP ADDRESS A0, A2, A3, A6 = VIL, A1 = VIH DATA = 01h NO End YES RP = VIH ++n = 25 ISSUE READ/RESET COMMAND RP = VIH PASS NO YES ISSUE READ/RESET COMMAND FAIL AI07758 1. Block Protection Groups are shown in Appendix D, Table 28. 2. RP can be either at VIH or at VID when using the In-System Technique to protect the Extended Block. 77/80 High voltage Block Protection M29DW641F Figure 25. In-System equipment Chip Unprotect flowchart START Set-up PROTECT ALL GROUPS n=0 CURRENT GROUP = 0 RP = VID WRITE 60h ANY ADDRESS WITH A0, A2, A3, A6 = VIL, A1 = VIH Unprotect WRITE 60h ANY ADDRESS WITH A0, A2, A3 = VIL, A1, A6 = VIH Wait 10ms Verify WRITE 40h ADDRESS = CURRENT GROUP ADDRESS A0, A2, A3 = VIL, A1 = VIH, A6 = VIL Wait 4µs INCREMENT CURRENT GROUP READ DATA ADDRESS = CURRENT GROUP ADDRESS A0, A2, A3 = VIL, A1 = VIH, A6 = VIL NO End NO DATA = 00h ++n = 1000 YES YES LAST GROUP NO YES RP = VIH RP = VIH ISSUE READ/RESET COMMAND ISSUE READ/RESET COMMAND FAIL PASS AI07759c 1. Block Protection Groups are shown in Appendix D, Table 28. 78/80 M29DW641F Revision history Revision history Table 37. Document revision history Date Revision Changes 02-Dec-2005 1 First issue. 10-Mar-2006 2 DQ7 changed to DQ7 for Program, Program During Erase Suspend and Program Error in Table 13: Status Register bits. Converted to new template. Updated address values in Table 35: Extended Block Address and Data. 19-Jun-2006 3 Small text changes. NVMP address corrected in Table 11: Protection command addresses. 24-Nov-2006 4 Updated RB for Program Error and Erase Error in Table 13: Status Register bits; updated package mechanical data for TSOP48 package in Section 11. 10-Dec-2007 5 Applied Numonyx branding. 79/80 M29DW641F Please Read Carefully: INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYX™ PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN NUMONYX'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY WHATSOEVER, AND NUMONYX DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications. Numonyx may make changes to specifications and product descriptions at any time, without notice. Numonyx, B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Numonyx reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Numonyx literature may be obtained by visiting Numonyx's website at http://www.numonyx.com. Numonyx StrataFlash is a trademark or registered trademark of Numonyx or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 11/5/7, Numonyx, B.V., All Rights Reserved. 80/80