Rectron FR601 Fast recovery rectifier (voltage range 50 to 1000 volts current 6.0 amperes) Datasheet

FR601
RECTRON
THRU
SEMICONDUCTOR
TECHNICAL SPECIFICATION
FR607
FAST RECOVERY RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 6.0 Amperes
FEATURES
*
*
*
*
*
*
Fast switching
Low leakage
Low forward voltage drop
High current capability
High currenf surge
High reliability
R-6
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 2.08 grams
1.0 (25.4)
MIN.
.052 (1.3)
DIA.
.048 (1.2)
.360 (9.1)
.340 (8.6)
.360 (9.1)
DIA.
.340 (8.6)
1.0 (25.4)
MIN.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25 oC unless otherwise noted)
SYMBOL
FR601
FR602
FR603
FR604
FR605
FR606
FR607
UNITS
Maximum Recurrent Peak Reverse Voltage
RATINGS
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
50
70
100
140
200
280
400
420
600
560
800
700
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T A = 75 oC
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
VDC
Volts
IO
6.0
Amps
I FSM
300
Amps
CJ
150
T J , T STG
-65 to + 150
pF
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 6.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage TA = 25 oC
Maximum Full Load Reverse Current Average,
Full Cycle .375” (9.5mm) lead length at T L = 55 oC
Maximum Reverse Recovery Time (Note 1)
NOTES : 1. Test Conditions: IF = 0.5A, IR = -1.0A, IRR = -0.25A
2. Measured at 1 MHZ and applied reverse voltage of 4.0 volts
SYMBOL
VF
FR601
FR602
FR603
FR604
1.3
FR605
FR606
FR607
10
UNITS
Volts
uAmps
IR
150
trr
150
uAmps
250
500
nSec
2001-5
FIG. 1 - TYPICAL FORWARD CURRENT
DERATING CURVE
8
6
4
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
2
FIG. 2 - MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWARD SURGE
CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTIC CURVES ( FR601 THRU FR607 )
600
8.3ms Single Half Sine-Wave
(JEDED Method)
500
400
300
200
100
0
0
0
25
50
75
100 125 150
AMBIENT TEMPERATURE, ( )
1
175
10
50
NUMBER OF CYCLES AT 60Hz
100
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
FIG. 4 - TYPICAL JUNCTION CAPACITANCE
200
500
100
40
10
TJ = 25
Pulse Width=300uS
1% Duty Cycle
1
100
JUNCTION CAPACITANCE, (pF)
INSTANTANEOUS FORWARD CURRENT, (A)
CHARACTERISTICS
1000
60
40
20
10
TJ = 25
6
4
2
0
1
.6
.8
1.0
1.2
1.4
1.6
1.8
.1
2.0
.2
INSTANTANEOUS FORWARD VOLTAGE, (V)
.4
1.0
2
4
10
20
REVERSE VOLTAGE, ( V )
FIG. 5 - TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
50
NONINDUCTIVE
10
NONINDUCTIVE
trr
+0.5A
(+)
25 Vdc
(approx)
(-)
(-)
D.U.T
PULSE
GENERATOR
(NOTE 2)
1
NONINDUCTIVE
OSCILLOSCOPE
(NOTE 1)
0
-0.25A
(+)
-1.0A
NOTES:1 Rise Time = 7ns max. Input Impedance =
1 megohm. 22pF.
2. Rise Time = 10ns max. Source Impedance =
50 ohms.
1cm
SET TIME BASE FOR
50/100 ns/cm
RECTRON
40
100
Similar pages