TSC HS1F 1.0amp high efficient surface mount rectifier Datasheet

HS1A - HS1M
creat by ART
1.0AMP High Efficient Surface Mount Rectifiers
SMA/DO-214AC
Pb
RoHS
COMPLIANCE
Features
—
Glass passivated junction chip.
—
For surface mounted application
—
Low forward voltage drop
—
Low profile package
—
Built-in stain relief, ideal for automatic
placement
—
Fast switching for high efficiency
—
High temperature soldering:
260℃/10 seconds at terminals
—
Plastic material used carries Underwriters
Laboratory Classification 94V-0
—
Green compound with suffix "G" on packing
code & prefix "G" on datecode
Mechanical Data
—
—
Cases: Molded plastic
Terminal: Pure tin plated, lead free
—
Polarity: Indicated by cathode band
Dimensions in inches and (millimeters)
Marking Diagram
HS1X = Specific Device Code
— Packing: 12mm tape per EIA STD RS-481
—
Weight: 0.064 grams
G
= Green Compound
Y
= Year
M
= Work Month
Maximum Ratings and Electrical Characteristics
Rating at 25 ℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
HS
1B
100
HS
1D
200
HS
1F
300
HS
1G
400
HS
1J
600
HS
1K
800
HS
1M
1000
Maximum Recurrent Peak Reverse Voltage
VRRM
HS
1A
50
Maximum RMS Voltage
VRMS
35
70
140
210
280
420
560
700
V
Maximum DC Blocking Voltage
VDC
50
100
200
300
400
600
800
1000
V
Maximum Average Forward Rectified Current
See Fig. 1
IF(AV)
1
A
Peak Forward Surge Current, 8.3 ms Single Half Sinewave Superimposed on Rated Load (JEDEC method)
IFSM
30
A
Type Number
Symbol
Maximum Instantaneous Forward Voltage (Note 1)
@1A
VF
Maximum DC Reverse
Current at Rated DC
Blocking Voltage
IR
@ T A=25 ℃
@ T A=100 ℃
@ T A=125 ℃
1.3
1.0
5
uA
150
Trr
50
75
Cj
20
15
Storage Temperature Range
V
50
Typical Junction Capacitance (Note 3)
Operating Temperature Range
V
1.7
Maximum Reverse Recovery Time (Note 2)
Typical Thermal Resistance
Units
nS
pF
O
RθJA
70
TJ
- 55 to + 150
O
C
- 55 to + 150
O
C
TSTG
Note 1: Pulse Test with PW=300 usec, 1% Duty Cycle
Note 2: Reverse Recovery Test Conditions: I F=0.5A, I R=1.0A, I RR=0.25A
Note 3: Measured at 1 MHz and Applied Reverse Voltage of 4.0Volts.
Version:F11
C/W
RATINGS AND CHARACTERISTIC CURVES (HS1A THRU HS1M)
FIG. 2- TYPICAL REVERSE CHARACTERISTICS
FIG.1- MAXIMUM AVERAGE FORWARD CURRENT
DERATING
1000
1
0.8
0.6
0.4
0.2
0
80
90
100
110
120
130
140
150
LEAD TEMPERATURE (oC)
INSTANTANEOUS REVERSE CURRENT (uA)
AVERAGE FORWARD
CURRENT (A)
1.2
TA=125℃
100
10
TA=25℃
1
0.1
40
PEAK FORWARD SURGE
URRENT (A)
0
FIG. 3- MAXIMUM NON-REPETITIVE FORWARD SURGE
CURRENT
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE
(%)
35
30
8.3mS Single Half Sine Wave
JEDEC Method
25
20
15
10
5
10
NUMBER OF CYCLES AT 60 Hz
100
100
FIG. 4- TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE (pF)
70
60
50
40
30
FIG. 5- TYPICAL INSTANTANEOUS
FORWARD CHARACTERISRICS
INSTANTANEOUS FORWARD CURRENT (A)
1
HS1A-HS1G
20
TA=25℃
10
HS1A-HS1D
1
HS1G
HS1J-HS1M
0.1
HS1J-HS1M
10
0
0.1
1
10
REVERSE VOLTAGE (V)
100
1000
0.01
0
0.2
0.4
0.6
0.8
1
1.2
FORWARD VOLTAGE (V)
1.4
1.6
Version:F11