MPE-150S Series Si l O Single Output, 150W 0 Compact, Enclosed AC/DC Power Supplies Electrical Specifications Key Features: • 150W Output Power • Selectable 88-264 AC Input • EN 60950 Compliant • Eight Single Output Models • Meets EN55022 Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current • >285 kHour MTBF Inrush Current • Compact Metal Enclosure Safety Ground Leakage Current Conditions Min. Typ. 88 115 176 220 248 47 See Model Selection Guide Cold Start, 115 VAC 17.0 Cold Start, 230 VAC 35.0 115 VAC 230 VAC Max. 132 264 370 63 1.5 3.5 mA Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 20 230 VAC 28 230 VAC 100 230 VAC 50 ±0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 110 Max. Units Switch Selectable Units VAC VDC Hz A Pk Output RoHS Compliant Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz), See Note 2 Hold-Up Time Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection mSec mSec mSec %/°C 135 160 General Parameter Isolation Voltage Isolation resistance EMI/RFI MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com EMC Compliance Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Switching Frequency Min. 3,000 1,500 500 Typ. Max. Units VAC 100 MΩ EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 25 kHz Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -10 +25 +60 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % Physical Case Size Case Material Weight 7.83 x 4.33 x 1.97 Inches (199.0 x 110.0 x 50.0 mm) Vented Metal Enclosure 28.3 Oz (0.8 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 285 kHours IEN 60950, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis Model Selection Guide Input Current (A) Model Number 115 VAC 230 VAC 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 MPE-150S-05 MPE-150S-09 MPE-150S-12 MPE-150S-13.5 MPE-150S-15 MPE-150S-24 MPE-150S-27 MPE-150S-48 Output Voltage (VDC) Rated 5.0 9.0 12.0 13.5 15.0 24.0 27.0 48.0 Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power supply terminals as possible. 3. The overvoltage protection circuit shuts down the output. The unit must be repowered to recover once the fault condition is removed. 4. The overload protection circuit shuts down the output. The unit must be repowered to recover once the fault condition is removed. 5. Efficiency is measured with a 115 VAC input. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPE-150S series, a 7.5A/250 VAC slow blow should be used. Adjust Current (A) Rated 4.5 - 5.5 8.0 - 10.4 10.6 - 13.2 12.0 - 15.0 13.5 - 16.5 21.0 - 28.0 24.0 - 30.0 43.0 - 53.0 30.0 16.7 12.5 11.2 10.0 6.5 5.6 3.2 Range Output Tolerance (%) 0 to 30.0 0 to 16.7 0 to 12.5 0 to 11.2 0 to 10.0 0 to 6.5 0 to 5.6 0 to 3.2 Ripple & Noise Efficiency (%, Typ) (mV p-p) ±2.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 150 180 180 180 180 240 240 240 78 80 82 83 84 85 86 87 Mechanical Dimensions Pin Connections Pin Function 1 2 3 4 5 6 7 AC-Line AC-Neutral AC-Ground -Vout -Vout +Vout +Vout Derating Curve Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Static Characteristics (24 Vout) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]