TI LM89 Accurate, remote diode and local digital temperature sensor with two-wire interface Datasheet

Sample &
Buy
Product
Folder
Support &
Community
Tools &
Software
Technical
Documents
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
LM89 ±0.75°C Accurate, Remote Diode And Local Digital Temperature Sensor
With Two-Wire Interface
1 Features
3 Description
•
The LM89 is an 11-bit digital temperature sensor with
a 2-wire System Management Bus (SMBus) serial
interface. The LM89 accurately measures its own
temperature as well as the temperature of an external
device, such as processor thermal diode or diodeconnected transistor such as the 2N3904. The
temperature of any ASIC, GPU, FPGA or MCU can
be accurately determined using the LM89 as long as
a dedicated diode (semiconductor junction) is
available on the target die. The LM89 has an Offset
register to allow calibration for different nonideality
factors without requiring software management.
1
•
•
•
•
•
•
•
•
Accurately Senses Die Temperature of Remote
ICs or Diode Junctions
Offset Register Allows Accurate Sensing of a
Variety of Thermal Diodes
On-Board Local Temperature Sensing
10-Bit Plus Sign Remote Diode Temperature Data
Format, 0.125°C Resolution
T_CRIT_A Output Useful for System Shutdown
ALERT Output Supports SMBus 2.0 Protocol
SMBus 2.0 Compatible Interface, Supports
TIMEOUT
8-Pin VSSOP and SOIC Packages
Key Specifications:
– Supply Voltage: 3.0 V to 3.6 V
– Local Temp Accuracy (includes quantization
error)
– TA = 25°C to 125°C ±3.0 °C (max)
– Remote Diode Temp Accuracy (includes
quantization error)
– TA = 30°C, TD = 80°C ±0.75 °C (max)
2 Applications
•
•
•
Processor/Computer System Thermal
Management
(For Example, Laptop, Desktop, Workstations,
Server)
Electronic Test Equipment
Office Electronics
Activation of the ALERT occurs when any
temperature goes outside a preprogrammed window
set by the HIGH and LOW limit registers or exceeds
the T_CRIT limit. Activation of the T_CRIT_A occurs
when any temperature exceeds the T_CRIT
programmed limit.
The LM89 is pin and register compatible with the
LM86, LM90, LM99, On Semiconductor ADM1032
and Maxim MAX6657/8.
The LM89C and the LM89-1C have the same
functions but different SMBus slave addresses,
allowing multiple LM89's on a bus. LM89-1D's default
local T_CRIT temperature limit is 105°C; all other
versions are 85°C. (See Device Comparison Table.)
Device Information(1)
PART NUMBER
PACKAGE
BODY SIZE (NOM)
LM89-1D
VSSOP (8)
3.0 mm x 3.0 mm
LM89C
SOIC (8)
4.9 mm x 3.9 mm
(1) For all available packages, see the orderable addendum at
the end of the datasheet.
4 Remote Diode Temperature Sensor System Diagram
Main Power Supply
Core Voltage
Shutdown Control
T_CRIT_A Temperature Response Diagram
3.3V derived
from Aux.
Supply
T_CRIT_A
MCU/
GPU/
ASIC/
FPGA
D+
2.2nF*
D-
LM89
SMBData
SMBCLK
ALERT
SMBus
Master
*Note: 2.2nF capacitor must be placed as close as possible to D+ and D- pins of the LM89.
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. UNLESS OTHERWISE NOTED, this document contains ADVANCE
INFORMATION for pre-production products; subject to change without notice.
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
Table of Contents
1
2
3
4
5
6
7
8
Features ..................................................................
Applications ...........................................................
Description .............................................................
Remote Diode Temperature Sensor System
Diagram...................................................................
Revision History.....................................................
Device Comparison Table.....................................
Pin Configuration And Functions ........................
Specifications.........................................................
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
9
1
1
1
1
2
3
3
4
Absolute Maximum Ratings ...................................... 4
Handling Ratings....................................................... 5
Recommended Operating Conditions....................... 5
Thermal Information .................................................. 5
Temperature-To-Digital Converter Characteristics ... 5
Digital DC Characteristics ......................................... 6
Timing Requirements ................................................ 6
SMBus Digital Switching Characteristics .................. 7
Typical Characteristics .............................................. 8
Detailed Description .............................................. 9
9.1
9.2
9.3
9.4
9.5
9.6
Overview ................................................................... 9
Functional Block Diagram ......................................... 9
Feature Description................................................... 9
Device Functional Modes........................................ 18
Programming .......................................................... 19
Register Maps ........................................................ 19
10 Application and Implementation........................ 24
10.1 Application Information.......................................... 24
10.2 Typical Application ............................................... 24
10.3 Do's and Don'ts .................................................... 26
11 Power Supply Recommendations ..................... 27
12 Layout................................................................... 28
12.1 Layout Guidelines ................................................. 28
12.2 Layout Example .................................................... 28
13 Device and Documentation Support ................. 29
13.1 Trademarks ........................................................... 29
13.2 Electrostatic Discharge Caution ............................ 29
13.3 Glossary ................................................................ 29
14 Mechanical, Packaging, and Orderable
Information ........................................................... 29
5 Revision History
Changes from Revision C (March 2013) to Revision D
Page
•
Changed data sheet flow and layout to conform with new Texas Instruments standards. Added the following
sections: Application and Implementation, Power Supply Recommendations, Layout, Device and Documentation
Support, Mechanical, Packaging, and Orderable Information................................................................................................ 1
•
Added information for LM89-1DIMM throughout document. .................................................................................................. 1
2
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
6 Device Comparison Table
Order Number
Local T_CRIT Threshold
Slave Address [A6:A0]
LM89CIM
85°C
100 1100
LM89CIMM
85°C
100 1100
LM89-1CIMM
85°C
100 1101
LM89-1DIMM
105°C
100 1101
7 Pin Configuration And Functions
8-Pin VSSOP or SOIC
DGK or D Packages
(TOP VIEW)
Pin Functions
PIN
DESCRIPTION
NAME
DGK or D
NUMBER
FUNCTION
TYPICAL CONNECTION
VDD
1
Positive Supply Voltage Input
DC Voltage from 3.0 V to 3.6 V. VDD should be bypassed with a 0.1µF
capacitor in parallel with 100pF. The 100pF capacitor should be
placed as close as possible to the power supply pin. A bulk
capacitance of approximately 10µF needs to be in the near vicinity to
the LM89 VDD.
D+
2
Diode Current Source
To Diode Anode. Connected to remote discrete diode-connected
transistor junction or to the diode-connected transistor junction on a
remote IC whose die temperature is being sensed. A 2.2 nF diode
bypass capacitor is required to filter high frequency noise. Place the
2.2 nF capacitor between and as close as possible to the LM89's D+
and D− pins. Make sure the traces to the 2.2 nF capacitor are
matched.
D−
3
Diode Return Current Sink
To Diode Cathode.
T_CRIT_A
4
T_CRIT Alarm Output, Open-Drain,
Active-Low
Pull-Up Resistor, Controller Interrupt or Power Supply Shutdown
Control
GND
5
Power Supply Ground
Ground
ALERT
6
Interrupt Output, Open-Drain,
Active-Low
Pull-Up Resistor, Controller Interrupt or Alert Line
SMBData
7
SMBus Bi-Directional Data Line,
Open-Drain Output
From and to Controller, Pull-Up Resistor
SMBCLK
8
SMBus Input
From Controller, Pull-Up Resistor
Table 1. ESD Protection (1)
Pin Name
PIN
NO.
D1
D2
VDD
1
D+
2
x
x
D−
3
x
x
T_CRIT_A
4
(1)
D3
D4
D5
D6
D7
R1
SNP
ESD
CLAMP
x
x
x
x
x
x
x
x
x
x
x
x
An “x” indicates that the component exists.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
3
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
Table 1. ESD Protection(1) (continued)
Pin Name
PIN
NO.
D1
D2
D3
D4
D5
D6
D7
R1
SNP
ALERT
6
x
x
x
SMBData
7
x
x
x
SMBCLK
8
ESD
CLAMP
x
V+
D1
D3
D4
D6
I/O
D2
SNP
ESD
Clamp
R1
D5
D7
GND
Figure 1. ESD Protection Input Structure
8 Specifications
8.1 Absolute Maximum Ratings (1) (2)
MIN
MAX
UNIT
Supply Voltage
−0.3
6.0
V
Voltage at SMBData, SMBCLK, ALERT, T_CRIT_A
−0.5
6.0
V
Voltage at Other Pins
−0.3
(VDD + 0.3 V)
V
D− Input Current
-1
+1
mA
Input Current at All Other Pins (3)
-5
+5
mA
Package Input Current (3)
30
mA
SMBData, ALERT, T_CRIT_A Output Sink Current
10
mA
Junction Temperature
Soldering Information, Lead Temperature
SOIC or VSSOP Packages (4)
(1)
(2)
(3)
(4)
4
150
°C
Vapor Phase (60
seconds)
215
°C
Infrared (15 seconds)
220
°C
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not
apply when operating the device beyond its rated operating conditions.
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > VDD), the current at that pin should be limited to 5
mA. Parasitic components and or ESD protection circuitry are shown in Table 1 and Figure 1 for the LM89's pins. The nominal
breakdown voltage of D3 is 6.5 V. Care should be taken not to forward bias the parasitic diode, D1, present on pins: D+, D−. Forward
biasing the parasitic diode by more than 50 mV may corrupt a temperature measurements.
Visit www.ti.com/packaging for other recommendations and methods of soldering surface mount devices.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
8.2 Handling Ratings
Tstg
V(ESD)
(1)
(2)
(3)
MIN
MAX
UNIT
-65
150
°C
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001, all
pins (1)
-2000
2000
Charged device model (CDM), per JEDEC specification
JESD22-C101, all pins; Applies only to LM89-1DiMM (2)
-1000
1000
Machine model ESD stress voltage, per JEDEC specification
JESD22-A115. (3)
-200
200
Storage temperature range
Electrostatic discharge
V
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
The machine model is a 200pF capacitor discharged directly into each pin.
8.3 Recommended Operating Conditions
Operating Temperature Range
MIN
MAX
UNIT
0
125
°C
TMIN ≤ TA ≤ TMAX
Electrical Characteristics Temperature Range
0°C ≤ TA ≤ +85°C
LM89
Supply Voltage Range (VDD)
3.0
3.6
LM89
LM89
V
8.4 Thermal Information
THERMAL METRIC
(1)
VSSOP
SOIC
8 PINS
8 PINS
RθJA
Junction-to-ambient thermal resistance
158
116
RθJC(top)
Junction-to-case (top) thermal resistance
52
63
RθJB
Junction-to-board thermal resistance
78
57
ψJT
Junction-to-top characterization parameter
5
11
ψJB
Junction-to-board characterization parameter
77
57
(1)
UNIT
°C/W
For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.
8.5 Temperature-To-Digital Converter Characteristics
Unless otherwise noted, these specifications apply for VDD= +3.0Vdc to 3.6Vdc. Unless otherwise noted, MIN and MAX limits
apply for TA = TJ = TMIN to TMAX and typical limits TA= TJ= +25°C.
PARAMETER
TEST CONDITIONS
(3)
MIN (1)
TYP (2)
MAX (1)
-3
±1
3
°C
UNIT
Temperature Error Using Local Diode
TA = +25°C to +125°C,
Temperature Error Using Remote Diode of 0.13
micron Pentium 4 or other devices with typical
nonideality of 1.0021 and series R= 3.64Ω.
TA = +30°C
TDiode = +80°C
-0.75
0.75
°C
TA = +30°C
to +50°C
TDiode = +60°C to
+100°C
-1
1
°C
TA = +0°C to
+85°C
TDiode = +25°C to
+125°C
-3
3
°C
Remote Diode Measurement Resolution
Local Diode Measurement Resolution
(1)
(2)
(3)
11
Bits
0.125
°C
8
Bits
1
°C
Limits are ensured to AOQL (Average Outgoing Quality Level).
Typical values are at TA = 25°C and represent most likely parametric norm.
Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the
internal power dissipation of the LM89 and the thermal resistance. See Thermal Information for the thermal resistance to be used in the
self-heating calculation.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
5
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
Temperature-To-Digital Converter Characteristics (continued)
Unless otherwise noted, these specifications apply for VDD= +3.0Vdc to 3.6Vdc. Unless otherwise noted, MIN and MAX limits
apply for TA = TJ = TMIN to TMAX and typical limits TA= TJ= +25°C.
TYP (2)
MAX (1)
SMBus Inactive, 16Hz conversion
rate
0.8
1.7
Shutdown
315
PARAMETER
Quiescent Current
TEST CONDITIONS
(4)
MIN (1)
D− Source Voltage
(D+ − D−) = +0.65V; high level
110
160
7
13
Low level
ALERT and T_CRIT_A Output Saturation
Voltage
IOUT = 6.0 mA
Power-On Reset Threshold
Measure on VDD input, falling
edge
1.8
mA
µA
0.7
Diode Source Current
UNIT
V
315
µA
20
µA
0.4
V
2.4
V
Local and Remote HIGH Default Temperature
settings
(5)
70
°C
Local and Remote LOW Default Temperature
settings
(5)
0
°C
Local T_CRIT Default Temperature Setting for
LM89-1C and LM89C
(5)
85
°C
105
°C
110
°C
Local T_CRIT Default Temperature Setting for
LM89-1D
(5)
Remote T_CRIT Default Temperature Setting
(4)
(5)
(5)
Limits are specific to TI's AOQL (Average Outgoing Quality Level).
Default values set at power up.
8.6 Digital DC Characteristics
Unless otherwise noted, these specifications apply for VDD = +3.0Vdc to 3.6Vdc. Unless otherwise noted, MIN and MAX limits
apply for TA = TJ = TMIN to TMAX and typical limits TA= TJ= +25°C.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN (1)
TYP (2)
MAX (1)
UNIT
SMBData, SMBCLK INPUTS
VIN(1)
Logical “1” Input Voltage
VIN(0)
Logical “0”Input Voltage
2.1
VIN(HYST)
SMBData and SMBCLK Digital Input
Hysteresis
IIN(1)
Logical “1” Input Current
VIN = VDD
IIN(0)
Logical “0” Input Current
VIN = 0 V
CIN
Input Capacitance
V
0.8
400
0.005
-10
V
mV
10
µA
−0.005
µA
5
pF
ALL DIGITAL OUTPUTS
IOH
High Level Output Current
VOH = VDD
10
µA
VOL
SMBus Low Level Output Voltage
IOL = 4mA
IOL = 6mA
0.4
0.6
V
(1)
(2)
Limits are specific to TI's AOQL (Average Outgoing Quality Level).
Typical values are at TA = 25°C and represent most likely parametric norm.
8.7 Timing Requirements
Unless otherwise noted, these specifications apply for VDD = +3.0Vdc to +3.6Vdc. Unless otherwise noted, MIN and MAX
limits apply for TA = TJ = TMIN to TMAX and typical limits TA= TJ= +25°C.
MIN (1)
PARAMETER
Conversion Time of All Temperatures at the Fastest Setting
(1)
(2)
(3)
6
(3)
TYP (2)
MAX (1)
31.25
34.4
UNIT
ms
Limits are specific to TI's AOQL (Average Outgoing Quality Level).
Typical values are at TA = 25°C and represent most likely parametric norm.
This specification is provided only to indicate how often temperature data is updated. The LM89 can be read at any time without regard
to conversion state (and will yield last conversion result)
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
8.8 SMBus Digital Switching Characteristics
Unless otherwise noted, these specifications apply for VDD = +3.0Vdc to +3.6Vdc, CL (load capacitance) on output lines = 80
pF. Unless otherwise noted, MIN and MAX limits apply for TA = TJ = TMIN to TMAX and typical limits TA= TJ= +25°C.
The switching characteristics of the LM89 fully meet or exceed the published specifications of the SMBus version 2.0. The
following parameters are the timing relationships between SMBCLK and SMBData signals related to the LM89. They adhere
to but are not necessarily the SMBus bus specifications.
SYMBOL
PARAMETER
MIN (1)
TEST CONDITIONS
TYP (2)
MAX (1)
Unit
fSMB
SMBus Clock Frequency
10
100
tLOW
SMBus Clock Low Time
from VIN(0)max to VIN(0)max
4.7
25,000
tHIGH
SMBus Clock High Time
from VIN(1)min to VIN(1)min
4.0
tR,SMB
SMBus Rise Time
(3)
1
tF,SMB
SMBus Fall Time
(4)
0.3
tOF
Output Fall Time
tTIMEOUT
SMBData and SMBCLK Time Low for Reset
of Serial Interface (5)
tSU;DAT
Data In Setup Time to SMBCLK High
250
tHD;DAT
Data Out Stable after SMBCLK Low
300
tHD;STA
Start Condition SMBData Low to SMBCLK
Low (Start condition hold before the first
clock falling edge)
100
ns
tSU;STO
Stop Condition SMBCLK High to SMBData
Low (Stop Condition Setup)
100
ns
tSU;STA
SMBus Repeated Start-Condition Setup
Time, SMBCLK High to SMBData Low
0.6
µs
tBUF
SMBus Free Time Between Stop and Start
Conditions
1.3
µs
(1)
(2)
(3)
(4)
(5)
kHz
µs
µs
µs
µs
CL = 400pF,
IO = 3mA, (4)
25
250
ns
35
ms
ns
900
ns
Limits are specific to TI's AOQL (Average Outgoing Quality Level).
Typical values are at TA = 25°C and represent most likely parametric norm.
The output rise time is measured from (VIN(0)max + 0.15V) to (VIN(1)min − 0.15V).
The output fall time is measured from (VIN(1)min - 0.15V) to (VIN(1)min + 0.15V).
Holding the SMBData and/or SMBCLK lines Low for a time interval greater than tTIMEOUT will reset the LM89's SMBus state machine,
therefore setting SMBData and SMBCLK pins to a high impedance state.
tLOW
tR
tF
VIH
SMBCLK
VIL
tBUF
tHD;STA
tHIGH
tHD;DAT
SMBDAT
VIH
VI
L
tSU;STA
tSU;DAT
tSU;STO
P
S
P
Figure 2. SMBus Communication
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
7
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
8.9 Typical Characteristics
2000
SUPPLY CURRENT (PA
1800
1600
140
0
1200
1000
800
600
400
0.01
0.1
1.0
10
100
CONVERSION RATE (Hz)
Figure 3. Conversion Rate Effect On Power Supply Current
8
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
9
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
Detailed Description
9.1 Overview
The LM89 temperature sensor incorporates a delta VBE based temperature sensor using a Local or Remote
diode and a 10-bit plus sign ADC (Delta-Sigma Analog-to-Digital Converter). The LM89 is compatible with the
serial SMBus version 2.0 two-wire interface. Digital comparators compare the measured Local Temperature (LT)
to the Local High (LHS), Local Low (LLS) and Local T_CRIT (LCS) user-programmable temperature limit
registers. The measured Remote Temperature (RT) is digitally compared to the Remote High (RHS), Remote
Low (RLS) and Remote T_CRIT (RCS) user-programmable temperature limit registers. Activation of the ALERT
output indicates that a comparison is greater than the limit preset in a T_CRIT or HIGH limit register or less than
the limit preset in a LOW limit register. The T_CRIT_A output responds as a true comparator with built in
hysteresis. The hysteresis is set by the value placed in the Hysteresis register (TH). Activation of T_CRIT_A
occurs when the temperature is above the T_CRIT setpoint. T_CRIT_A remains activated until the temperature
goes below the setpoint calculated by T_CRIT − TH. The hysteresis register impacts both the remote
temperature and local temperature readings.
The LM89 may be placed in a low power consumption (Shutdown) mode by setting the RUN/STOP bit found in
the Configuration register. In the Shutdown mode, the LM89's SMBus interface remains while all circuitry not
required is turned off.
The Local temperature reading and setpoint data registers are 8-bits wide. The format of the 11-bit remote
temperature data is a 16-bit left justified word. Two 8-bit registers, high and low bytes, are provided for each
setpoint as well as the temperature reading. Two offset registers (RTOLB and RTOHB) can be used to
compensate for nonideality error, discussed further in Diode Nonideality. The remote temperature reading
reported is adjusted by subtracting from or adding to the actual temperature reading the value placed in the
offset registers.
9.2 Functional Block Diagram
3.0V-3.6V
Fault
Queue
10-Bit Plus Sign
'-6
Converter
Temperature
Sensor
Circuitry
D+
D-
Programable
Level
Filter
S
Q
ALERT
R
Fault
Queue
Local/Remote
Diode Selector
Fault
Queue
Control Logic
One Shot
Register
Remote Offset
Registers
Local/Remote
Temperature
Registers
HIGH
Limit
Registers
T_Crit_A
LOW
Limit
Registers
T_CRIT Limit Configuration Conversion
& Hysteresis
Rate
and Status
Registers
Registers
Registers
Two-Wire Serial
Interface
SMBData
SMBClock
9.3 Feature Description
9.3.1 Conversion Sequence
The LM89 takes approximately 31.25 ms to convert the Local Temperature (LT), Remote Temperature (RT), and
to update all of its registers. Only during the conversion process the busy bit (D7) in the Status register (02h) is
high. These conversions are addressed in a round robin sequence. The conversion rate may be modified by the
Conversion Rate Register (04h). When the conversion rate is modified a delay is inserted between conversions,
the actual conversion time remains at 31.25 ms. Different conversion rates will cause the LM89 to draw different
amounts of supply current as shown in Figure 4.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
9
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
Feature Description (continued)
2000
SUPPLY CURRENT (PA
1800
1600
140
0
1200
1000
800
600
400
0.01
0.1
1.0
10
100
CONVERSION RATE (Hz)
Figure 4. Conversion Rate Effect On Power Supply Current
9.3.2 The ALERT Output
The LM89's ALERT pin is an active-low open-drain output that is triggered by a temperature conversion that is
outside the limits defined by the temperature setpoint registers. Reset of the ALERT output is dependent upon
the selected method of use. The LM89's ALERT pin is versatile and will accommodate three different methods of
use to best serve the system designer: as a temperature comparator, as a temperature based interrupt flag, and
as part of an SMBus ALERT system. The three methods of use are further described below. The ALERT and
interrupt methods are different only in how the user interacts with the LM89.
Each temperature reading (LT and RT) is associated with a T_CRIT setpoint register (LCS, RCS), a HIGH
setpoint register (LHS and RHS) and a LOW setpoint register (LLS and RLS). At the end of every temperature
reading, a digital comparison determines whether that reading is above its HIGH or T_CRIT setpoint or below its
LOW setpoint. If so, the corresponding bit in the STATUS REGISTER is set. If the ALERT mask bit is not high,
any bit set in the STATUS REGISTER, with the exception of Busy (D7) and OPEN (D2), will cause the ALERT
output to be pulled low. Any temperature conversion that is out of the limits defined by the temperature setpoint
registers will trigger an ALERT. Additionally, the ALERT mask bit in the Configuration register must be cleared to
trigger an ALERT in all modes.
9.3.2.1
ALERT Output As A Temperature Comparator
When the LM89 is implemented in a system in which it is not serviced by an interrupt routine, the ALERT output
could be used as a temperature comparator. Under this method of use, once the condition that triggered the
ALERT to go low is no longer present, the ALERT is de-asserted (Figure 5). For example, if the ALERT output
was activated by the comparison of LT > LHS, when this condition is no longer true the ALERT will return HIGH.
This mode allows operation without software intervention, once all registers are configured during set-up. In order
for the ALERT to be used as a temperature comparator, bit D0 (the ALERT configure bit) in the FILTER and
ALERT CONFIGURE REGISTER (BFh) must be set high. This is not the power-on-default state.
10
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
Feature Description (continued)
TEMPERATURE
Remote High Limit
RDTS Measurement
LM89 ALERT Pin
Status Register: RTDS High
TIME
Figure 5. ALERT Comparator Temperature Response Diagram
9.3.2.2
ALERT Output As An Interrupt
The LM89's ALERT output can be implemented as a simple interrupt signal when it is used to trigger an interrupt
service routine. In such systems it is undesirable for the interrupt flag to repeatedly trigger during or before the
interrupt service routine has been completed. Under this method of operation, during a read of the STATUS
REGISTER the LM89 will set the ALERT mask bit (D7 of the Configuration register) if any bit in the STATUS
REGISTER is set, with the exception of Busy (D7) and OPEN (D2). This prevents further ALERT triggering until
the master has reset the ALERT mask bit, at the end of the interrupt service routine. The STATUS REGISTER
bits are cleared only upon a read command from the master (see Figure 6) and will be re-asserted at the end of
the next conversion if the triggering condition(s) persist(s). In order for the ALERT to be used as a dedicated
interrupt signal, bit D0 (the ALERT configure bit) in the FILTER and ALERT CONFIGURE REGISTER (BFh)
must be set low. This is the power-on-default state.
The following sequence describes the response of a system that uses the ALERT output pin as a interrupt flag:
1. Master Senses ALERT low
2. Master reads the LM89 STATUS REGISTER to determine what caused the ALERT
3. LM89 clears STATUS REGISTER, resets the ALERT HIGH and sets the ALERT mask bit (D7 in the
Configuration register).
4. Master attends to conditions that caused the ALERT to be triggered. The fan is started, setpoint limits are
adjusted, etc.
5. Master resets the ALERT mask (D7 in the Configuration register).
TEMPERATURE
RDTS Measurement
Remote High Limit
LM89 ALERT pin
ALERT mask set in
response to reading of
status register by
master
End of Temperature
conversion
Status Register: RTDS High
TIME
Figure 6. ALERT Output As An Interrupt Temperature Response Diagram
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
11
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
Feature Description (continued)
9.3.2.3
ALERT Output As An SMBus Alert
When the ALERT output is connected to one or more ALERT outputs of other SMBus compatible devices and to
a master, an SMBus alert line is created. Under this implementation, the LM89's ALERT should be operated
using the ARA (Alert Response Address) protocol. The SMBus 2.0 ARA protocol, defined in the SMBus
specification 2.0, is a procedure designed to assist the master in resolving which part generated an interrupt and
service that interrupt while impeding system operation as little as possible.
The SMBus alert line is connected to the open-drain ports of all devices on the bus thereby AND'ing them
together. The ARA is a method by which with one command the SMBus master may identify which part is pulling
the SMBus alert line LOW and prevent it from pulling it LOW again for the same triggering condition. When an
ARA command is received by all devices on the bus, the devices pulling the SMBus alert line LOW, first, send
their address to the master and second, release the SMBus alert line after recognizing a successful transmission
of their address.
The SMBus 1.1 and 2.0 specification state that in response to an ARA (Alert Response Address) “after
acknowledging the slave address the device must disengage its SMBALERT pulldown”. Furthermore, “if the host
still sees SMBALERT low when the message transfer is complete, it knows to read the ARA again”. This SMBus
“disengaging of SMBALERT” requirement prevents locking up the SMBus alert line. Competitive parts may
address this “disengaging of SMBALERT” requirement differently than the LM89 or not at all. SMBus systems
that implement the ARA protocol as suggested for the LM89 will be fully compatible with all competitive parts.
The LM89 fulfills “disengaging of SMBALERT” by setting the ALERT mask bit (bit D7 in the Configuration
register, at address 09h) after successfully sending out its address in response to an ARA and releasing the
ALERT output pin. Once the ALERT mask bit is activated, the ALERT output pin will be disabled until enabled by
software. In order to enable the ALERT the master must read the STATUS REGISTER, at address 02h, during
the interrupt service routine and then reset the ALERT mask bit in the Configuration register to 0 at the end of
the interrupt service routine.
The following sequence describes the ARA response protocol.
1. Master Senses SMBus alert line low
2. Master sends a START followed by the Alert Response Address (ARA) with a Read Command.
3. Alerting Device(s) send ACK.
4. Alerting Device(s) send their Address. While transmitting their address, alerting devices sense whether their
address has been transmitted correctly. (The LM89 will reset its ALERT output and set the ALERT mask bit
once its complete address has been transmitted successfully.)
5. Master/slave NoACK
6. Master sends STOP
7. Master attends to conditions that caused the ALERT to be triggered. The STATUS REGISTER is read and
fan started, setpoint limits adjusted, etc.
8. Master resets the ALERT mask (D7 in the Configuration register).
The ARA, 000 1100, is a general call address. No device should ever be assigned this address.
Bit D0 (the ALERT configure bit) in the FILTER and ALERT CONFIGURE REGISTER (BFh) must be set low in
order for the LM89 to respond to the ARA command.
The ALERT output can be disabled by setting the ALERT mask bit, D7, of the Configuration register. The poweron-default is to have the ALERT mask bit and the ALERT configure bit low.
12
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
Feature Description (continued)
TEMPERATURE
Remote High Limit
RDTS Measurement
LM89 ALERT pin
ALERT mask set in
response to ARA
from master
Status Register: RTDS High
TIME
Figure 7. ALERT Output As An Smbus Alert Temperature Response Diagram
9.3.3
T_CRIT_A Output And T_CRIT Limit
T_CRIT_A is activated when any temperature reading is greater than the limit preset in the critical temperature
setpoint register (T_CRIT), as shown in Figure 8. The Status Register can be read to determine which event
caused the alarm. A bit in the Status Register is set high to indicate which temperature reading exceeded the
T_CRIT setpoint temperature and caused the alarm, see Status Register (SR).
Local and remote temperature diodes are sampled in sequence by the A/D converter. The T_CRIT_A output and
the Status Register flags are updated after every Local and Remote temperature conversion. T_CRT_A follows
the state of the comparison, it is reset when the temperature falls below the setpoint RCS-TH. The Status
Register flags are reset only after the Status Register is read and if a temperature conversion(s) is/are below the
T_CRIT setpoint, as shown in Figure 8.
Figure 8. T_CRIT_A Temperature Response Diagram
9.3.4 Smbus Interface
The LM89 operates as a slave on the SMBus, so the SMBCLK line is an input and the SMBData line is bidirectional. The LM89 never drives the SMBCLK line and it does not support clock stretching. According to
SMBus specifications, the LM89 has a 7-bit slave address. All bits A6 through A0 are internally programmed and
can not be changed by software or hardware. The LM89 and LM89-1 versions have the following SMBus slave
addresses:
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
13
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
Version
A6
A5
A4
A3
A2
A1
A0
LM89CIM, LM89CIMM
1
0
0
1
1
0
0
LM89-1CIMM, LM891DIMM
1
0
0
1
1
0
1
9.3.5 Temperature Data Format
Temperature data can only be read from the Local and Remote Temperature registers; the setpoint registers
(T_CRIT, LOW, HIGH) are read/write.
Remote temperature data is represented by an 11-bit, two's complement word with an LSB (Least Significant Bit)
equal to 0.125°C. The data format is a left justified 16-bit word available in two 8-bit registers:
Temperature
Digital Output
Binary
Hex
+125°C
0111 1101 0000 0000
7D00h
+25°C
0001 1001 0000 0000
1900h
+1°C
0000 0001 0000 0000
0100h
+0.125°C
0000 0000 0010 0000
0020h
0°C
0000 0000 0000 0000
0000h
−0.125°C
1111 1111 1110 0000
FFE0h
−1°C
1111 1111 0000 0000
FF00h
−25°C
1110 0111 0000 0000
E700h
−55°C
1100 1001 0000 0000
C900h
Local Temperature data is represented by an 8-bit, two's complement byte with an LSB (Least Significant Bit)
equal to 1°C:
Temperature
9.3.6
Digital Output
Binary
Hex
+125°C
0111 1101
7Dh
+25°C
0001 1001
19h
+1°C
0000 0001
01h
0°C
0000 0000
00h
−1°C
1111 1111
FFh
−25°C
1110 0111
E7h
−55°C
1100 1001
C9h
Open-Drain Outputs
The SMBData, ALERT and T_CRIT_A outputs are open-drain outputs and do not have internal pull-ups. A “high”
level will not be observed on these pins until pull-up current is provided by some external source, typically a pullup resistor. Choice of resistor value depends on many system factors but, in general, the pull-up resistor should
be as large as possible. This will minimize any internal temperature reading errors due to internal heating of the
LM89. The maximum resistance of the pull-up to provide a 2.1V high level, based on LM89 specification for High
Level Output Current with the supply voltage at 3.0V, is 82kΩ(5%) or 88.7kΩ(1%).
9.3.7 Diode Fault Detection
The LM89 is equipped with operational circuitry designed to detect fault conditions concerning the remote diode.
In the event that the D+ pin is detected as shorted to VDD or floating, the Remote Temperature High Byte (RTHB)
register is loaded with +127°C, the Remote Temperature Low Byte (RTLB) register is loaded with 0, and the
OPEN bit (D2) in the status register is set. As a result, if the Remote T_CRIT setpoint register (RCS) is set to a
value less than +127°C the ALERT and T_Crit output pins will be pulled low, if the Alert Mask and T_Crit Mask
are disabled. If the Remote HIGH Setpoint High Byte Register (RHSHB) is set to a value less than +127°C then
ALERT will be pulled low, if the Alert Mask is disabled. The OPEN bit itself will not trigger and ALERT.
14
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
In the event that the D+ pin is shorted to ground or D−, the Remote Temperature High Byte (RTHB) register is
loaded with −128°C (1000 0000) and the OPEN bit (D2) in the status register will not be set. Since operating the
LM89 at −128°C is beyond it's operational limits, this temperature reading represents this shorted fault condition.
If the value in the Remote Low Setpoint High Byte Register (RLSHB) is more than −128°C and the Alert Mask is
disabled, ALERT will be pulled low.
Remote diode temperature sensors that have been previously released and are competitive with the LM89 output
a code of 0°C if the external diode is short-circuited. This change is an improvement that allows a reading of 0°C
to be truly interpreted as a genuine 0°C reading and not a fault condition.
9.3.8 Communicating With The LM89
The data registers in the LM89 are selected by the Command Register. At power-up the Command Register is
set to “00”, the location for the Read Local Temperature Register. The Command Register latches the last
location it was set to. Each data register in the LM89 falls into one of four types of user accessibility:
1. Read only
2. Write only
3. Read/Write same address
4. Read/Write different address
A Write to the LM89 will always include the address byte and the command byte. A write to any register requires
one data byte.
Reading the LM89 can take place either of two ways:
1. If the location latched in the Command Register is correct (most of the time it is expected that the Command
Register will point to one of the Read Temperature Registers because that will be the data most frequently
read from the LM89), then the read can simply consist of an address byte, followed by retrieving the data
byte.
2. If the Command Register needs to be set, then an address byte, command byte, repeat start, and another
address byte will accomplish a read.
The data byte has the most significant bit first. At the end of a read, the LM89 can accept either acknowledge or
No Acknowledge from the Master (No Acknowledge is typically used as a signal for the slave that the Master has
read its last byte). It takes the LM89 31.25 ms to measure the temperature of the remote diode and internal
diode. When retrieving all 11 bits from a previous remote diode temperature measurement, the master must
insure that all 11 bits are from the same temperature conversion. This may be achieved by reading the MSB
(most significant byte first) followed by the LSB (least significant byte). Reading the MSB first will lock the LSB,
thus synchronizing the two bytes. One-shot mode can also be used without any restrictions on the MSB and LSB
reading sequence.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
15
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
9.3.8.1 SMBus Timing Diagrams
Figure 9. LM89 Timing Diagram
(A) Serial Bus Write To The Internal Command Register Followed By A The Data Byte
Figure 10. LM89 Timing Diagram
(B) Serial Bus Write To The Internal Command Register
1
9
1
9
SMBCLK
SMBDat
a
A6
A5
Start
by
Master
A4
A3
A2
A1
A0
D7
R/W
D6
D5
D4
D3
D2
D1
Ack
by
LM89
Address byte.
Frame 1
Serial Bus Address Byte
D0
No Ack Stop
by
by
Master Master
Frame 2
Data Byte from the LM89
Figure 11. LM89 Timing Diagram
(C) Serial Bus Read From A Register With The Internal Command Register Preset To Desired Value
9.3.9 Serial Interface Reset
In the event that the SMBus Master is RESET while the LM89 is transmitting on the SMBData line, the LM89
must be returned to a known state in the communication protocol. This may be done in one of two ways:
1. When SMBData is LOW, the LM89 SMBus state machine resets to the SMBus idle state if either SMBData
or SMBCLK are held low for more than 35 ms (tTIMEOUT). Note that according to SMBus specification 2.0 all
devices are to timeout when either the SMBCLK or SMBData lines are held low for 25-35 ms. Therefore, to
insure a timeout of all devices on the bus the SMBCLK or SMBData lines must be held low for at least 35
ms.
2. When SMBData is HIGH, have the master initiate an SMBus start. The LM89 will respond properly to an
16
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
SMBus start condition at any point during the communication. After the start the LM89 will expect an SMBus
address byte.
9.3.10 Digital Filter
In order to suppress erroneous remote temperature readings due to noise, the LM89 incorporates a userconfigured digital filter. The filter is accessed in the FILTER and ALERT CONFIGURE REGISTER at BFh. The
filter can be set according to the following table.
D2
D1
0
0
Filter
No Filter
0
1
Level 1
1
0
Level 1
1
1
Level 2
Level 2 sets maximum filtering.
Figure 13 depicts the filter output in response to a step input and an impulse input. Figure 14 depicts the digital
filter in use in a Pentium 4 processor system. Note that the two curves, with filter and without, have been
purposely offset so that both responses can be clearly seen. Inserting the filter does not induce an offset as
shown.
Figure 12. Filter Output Response To A Step Input
A) Step Response
Figure 13. Filter Output Response To A Step Input
B) Impulse Response
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
17
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
45
LM89
with
Filter Off
43
TEMPERATURE (oC)
41
39
37
35
LM89
with
Filter On
33
31
29
27
25
0
50
100
150
200
SAMPLE NUMBER
A.
The filter on and off curves were purposely offset to better show noise performance.
Figure 14. Digital Filter Response In A Pentium 4 Processor System
9.3.11 Fault Queue
TEMPERATURE
In order to suppress erroneous ALERT or T_CRIT triggering the LM89 incorporates a Fault Queue. The Fault
Queue acts to insure a remote temperature measurement is genuinely beyond a HIGH, LOW or T_CRIT setpoint
by not triggering until three consecutive out of limit measurements have been made, see Figure 15. The fault
queue defaults off upon power-up and may be activated by setting bit D0 in the Configuration register (09h) to
“1”.
RDTS Measurement
Status Register: RTDS High
n
n+1
n+2
n+3
n+4
n+5
SAMPLE NUMBER
Figure 15. Fault Queue Temperature Response Diagram
9.3.12 One-Shot Register
The One-Shot register is used to initiate a single conversion and comparison cycle when the device is in standby
mode, after which the device returns to standby. This is not a data register and it is the write operation that
causes the one-shot conversion. The data written to this address is irrelevant and is not stored. A zero will
always be read from this register.
9.4 Device Functional Modes
9.4.1 Power-On-Default States
LM89 always powers up to these known default states. The LM89 remains in these states until after the first
conversion.
1. Command Register set to 00h
18
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
Device Functional Modes (continued)
2.
3.
4.
5.
Local Temperature set to 0°C
Remote Diode Temperature set to 0°C until the end of the first conversion.
Status Register set to 00h.
Configuration register set to 00h; ALERT enabled, Remote T_CRIT alarm enabled and Local T_CRIT alarm
enabled
6. 85°C Local T_CRIT temperature setpoint for LM89C and LM89-1C; 105°C Local T_CRIT temperature
setpoint for LM89-1D
7. 110°C Remote T_CRIT temperature setpoint
8. 70°C Local and Remote HIGH temperature setpoints
9. 0°C Local and Remote LOW temperature setpoints
10. Filter and Alert Configure Register set to 00h; filter disabled, ALERT output set as an SMBus ALERT
11. Conversion Rate Register set to 8h; conversion rate set to 16 conv./sec.
9.5 Programming
9.6 Register Maps
9.6.1 Command Register
Selects which registers will be read from or written to. Data for this register should be transmitted during the
Command Byte of the SMBus write communication.
P7
P6
P5
P4
P3
P2
P1
P0
Command Select
P0-P7: Command Select
Command Select Address
Power-On-Default State
Register
Name
Register Function
Read Address
<P7:P0> hex
Write Address
<P7:P0> hex
<D7:D0> binary
<D7:D0>
decimal
00h
NA
0000 0000
0
LT
01h
NA
0000 0000
0
RTHB
02h
NA
0000 0000
0
SR
03h
09h
0000 0000
0
C
04h
0Ah
0000 1000
8 (16
conv./sec)
CR
Conversion Rate
05h
0Bh
0100 0110
70
LHS
Local HIGH Setpoint
06h
0Ch
0000 0000
0
LLS
Local LOW Setpoint
07h
0Dh
0100 0110
70
RHSHB
Remote HIGH Setpoint High Byte
08h
0Eh
0000 0000
0
RLSHB
Remote LOW Setpoint High Byte
NA
0Fh
One Shot
Local Temperature
Remote Temperature High Byte
Status Register
Configuration
Writing to this register will initiate a
one shot conversion
10h
NA
0000 0000
0
RTLB
11h
11h
0000 0000
0
RTOHB
Remote Temperature Low Byte
Remote Temperature Offset High
Byte
12h
12h
0000 0000
0
RTOLB
Remote Temperature Offset Low
Byte
13h
13h
0000 0000
0
RHSLB
Remote HIGH Setpoint Low Byte
14h
14h
0000 0000
0
RLSLB
Remote LOW Setpoint Low Byte
19h
19h
0110 1110
110
RCS
Remote T_CRIT Setpoint
20h
20h
LM89C 0101 0101
LM89-1C 0101 0101
LM89-1D 0110 1001
85
85
105
LCS
Local T_CRIT Setpoint
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
19
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
Command Select Address
Read Address
<P7:P0> hex
www.ti.com
Power-On-Default State
Register
Name
Register Function
Write Address
<P7:P0> hex
<D7:D0> binary
<D7:D0>
decimal
0000 1010
10
TH
0000 0000
0
RDTF
Remote Diode Temperature Filter
1
RMID
Read Manufacturer's ID
49
52
53
RDR
Read Stepping or Die Revision Code
21h
21h
B0h-BEh
B0h-BEh
BFh
BFh
FEh
NA
FFh
NA
T_CRIT Hysteresis
Manufacturers Test Registers
0000 0001
LM89C 0011 0001
LM89-1C 0011 0100
LM89-1D 0011 0101
9.6.2 Local And Remote Temperature Registers (LT, RTHB, RTLB)
Table 2. Local And Remote Temperature Registers (LT, RTHB) (Read Only Address 00h, 01h):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
For LT and RTHB D7–D0: Temperature Data. LSB = 1°C. Two's complement format.
Table 3. Local And Remote Temperature Registers (RTLB) (Read Only Address 10h):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0
0
0
0
0
For RTLB D7–D5: Temperature Data. LSB = 0.125°C. Two's complement format.
The maximum value available from the Local Temperature register is 127; the minimum value available from the
Local Temperature register is -128. The maximum value available from the Remote Temperature register is
127.875; the minimum value available from the Remote Temperature registers is −128.875.
9.6.3 Status Register (SR)
Table 4. Status Register (SR) (Read Only Address 02h):
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Value
Busy
LHIGH
LLOW
RHIGH
RLOW
OPEN
RCRIT
LCRIT
Power up default is with all bits “0” (zero).
D7: Busy: When set to “1” ADC is busy converting.
D6: LHIGH: When set to “1” indicates a Local HIGH Temperature alarm.
D5: LLOW: When set to “1” indicates a Local LOW Temperature alarm.
D4: RHIGH: When set to “1” indicates a Remote Diode HIGH Temperature alarm.
D3: RLOW: When set to “1” indicates a Remote Diode LOW Temperature alarm
D2: OPEN: When set to “1” indicates a Remote Diode disconnect.
D1: RCRIT: When set to “1” indicates a Remote Diode Critical Temperature alarm.
D0: LCRIT: When set to “1” indicates a Local Critical Temperature alarm.
9.6.4 Configuration Register
Table 5. Configuration Register (Read Address 03h /Write Address 09h):
20
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Value
ALERT mask
RUN/STOP
0
Remote
T_CRIT_A
mask
0
Local
T_CRIT_A
mask
0
Fault Queue
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
Power up default is with all bits “0” (zero)
D7: ALERT mask: When set to “1” ALERT interrupts are masked.
D6: RUN/STOP: When set to “1” SHUTDOWN is enabled.
D5: is not defined and defaults to “0”.
D4: Remote T_CRIT mask: When set to “1” a diode temperature reading that exceeds T_CRIT setpoint will not
activate the T_CRIT_A pin.
D3: is not defined and defaults to “0”.
D2: Local T_CRIT mask: When set to “1” a Local temperature reading that exceeds T_CRIT setpoint will not
activate the T_CRIT_A pin.
D1: is not defined and defaults to “0”.
D0: Fault Queue: when set to “1” three consecutive remote temperature measurements outside the HIGH, LOW,
or T_CRIT setpoints will trigger an “Outside Limit” condition resulting in setting of status bits and associated
output pins..
9.6.5 Conversion Rate Register
Table 6. Conversion Rate Register (Read Address 04h
/Write Address 0Ah)
Value
Conversion Rate
00
62.5 mHz
01
125 mHz
02
250 mHz
03
500 mHz
04
1 Hz
05
2 Hz
06
4 Hz
07
8 Hz
08
16 Hz
09
32 Hz
10-255
Undefined
9.6.6 Local And Remote High Setpoint Registers (LHS, RHSHB, And RHSLB)
Table 7. Local And Remote High Setpoint Registers (LHS, RHSHB) (Read Address 05h, 07h /Write
Address 0Bh, 0Dh):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
For LHS and RHSHB: HIGH setpoint temperature data. Power up default is LHIGH = RHIGH = 70°C. 1 LSB =
1°C. Two's complement format.
Table 8. Local And Remote High Setpoint Registers (RHSLB) (Read/Write Address 13h):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0
0
0
0
0
For RHSLB: Remote HIGH Setpoint Low Byte temperature data. Power up default is 0°C. 1 LSB = 0.125°C.
Two's complement format.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
21
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
9.6.7 Local And Remote Low Setpoint Registers (LLS, RLSHB, And RLSLB)
Table 9. Local And Remote Low Setpoint Registers (LLS, RLSHB) (Read Address 06h, 08h, /Write
Address 0Ch, 0Eh):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
For LLS and RLSHB: HIGH setpoint temperature data. Power up default is LHIGH = RHIGH = 0°C. 1 LSB = 1°C.
Two's complement format.
Table 10. Local And Remote Low Setpoint Registers (RLSLB) (Read/Write Address 14h):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0
0
0
0
0
For RLSLB: Remote HIGH Setpoint Low Byte temperature data. Power up default is 0°C. 1 LSB = 0.125°C.
Two's complement format.
9.6.8 Remote Temperature Offset Registers (RTOHB And RTOLB)
Table 11. Remote Temperature Offset Registers (RTOHB)(Read/Write Address 11h):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
For RTOHB: Remote Temperature Offset High Byte. Power up default is LHIGH = RHIGH = 0°C. 1 LSB = 1°C.
Two's complement format.
Table 12. Remote Temperature Offset Registers (RTOLB) (Read/Write Address 12h):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0
0
0
0
0
For RTOLB: Remote Temperature Offset High Byte. Power up default is 0°C. 1 LSB = 0.125°C. Two's
complement format.
The offset value written to these registers will automatically be added to or subtracted from the remote
temperature measurement that will be reported in the Remote Temperature registers.
9.6.9 Local And Remote T_crit Registers (RCS And LCS)
Table 13. Local And Remote T_CRIT Registers (RCS And LCS) (Read/Write Address 20h, 19h):
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
D7–D0: T_CRIT setpoint temperature data. Power up default is Local T_CRIT = 85°C (LM89C and LM89-1C) or
105°C (LM89-1D), and Remote T_CRIT=110°C. 1 LSB = 1°C, two's complement format.
9.6.10 T_CRIT Hysteresis Register (TH)
Table 14. T_CRIT Hysteresis Register (TH) (Read And Write Address 21h):
BIT
D7
Value
22
D6
D5
D4
D3
D2
D1
D0
16
8
4
2
1
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
D7–D0: T_CRIT Hysteresis temperature. Power up default is TH = 10°C. 1 LSB = 1°C, maximum value = 31.
9.6.11 Filter And Alert Configure Register
Table 15. Filter And Alert Configure Register (Read And Write Address BFh):
BIT
D7
D6
D5
D4
D3
Value
0
0
0
0
0
D2
D1
Filter Level
D0
ALERT Configure
D7-D3: is not defined defaults to "0".
D2-D1: input filter setting as defined the table below:
D2
D1
Filter Level
0
0
No Filter
0
1
Level 1
1
0
Level 1
1
1
Level 2
Level 2 sets maximum filtering.
D0: when set to "1" comparator mode is enabled.
9.6.12 Manufacturers Id Register
(Read Address FEh) The default value is 01h.
9.6.13 Die Revision Code Register
(Read Address FFh) The LM89C version has a default value of 31h or 49 decimal. The LM89-1C version has a
default value of 34h or 52 decimal. The LM89-1D has a default value of 35h or 53 decimal. This register will
increment by 1 every time there is a revision to the die by Texas Instruments.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
23
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
10 Application and Implementation
10.1 Application Information
The LM89 can be applied easily in the same way as other integrated-circuit temperature sensors, and its remote
diode sensing capability allows it to be used in new ways as well. It can be soldered to a printed circuit board,
and because the path of best thermal conductivity is between the die and the pins, its temperature will effectively
be that of the printed circuit board lands and traces soldered to the LM89's pins. This presumes that the ambient
air temperature is almost the same as the surface temperature of the printed circuit board; if the air temperature
is much higher or lower than the surface temperature, the actual temperature of the LM89 die will be at an
intermediate temperature between the surface and air temperatures. Again, the primary thermal conduction path
is through the leads, so the circuit board temperature will contribute to the die temperature much more strongly
than will the air temperature.
To measure temperature external to the LM89's die, use a remote diode. This diode can be located on the die of
a target IC, allowing measurement of the IC's temperature, independent of the LM89's temperature.
10.2 Typical Application
The LM89 has been optimized to measure the remote thermal diode of a 0.13 micron Pentium 4, a Mobile
Pentium 4 Processor-M processor or other embedded thermal diodes that have similar characteristics. A discrete
diode can also be used to sense the temperature of external objects or ambient air. Remember that a discrete
diode's temperature will be affected, and often dominated, by the temperature of its leads. Most silicon diodes do
not lend themselves well to this application. It is recommended that a MMBT3904 transistor base emitter junction
be used with the collector tied to the base (diode-connected).
An LM89 with a diode-connected MMBT3904 will have a typical -1°C offset.
T2N3904 = TLM89 +1°C
Main Power Supply
Core Voltage
Shutdown Control
3.3V derived
from Aux.
Supply
T_CRIT_A
MCU/
GPU/
ASIC/
FPGA
D+
2.2nF*
D-
LM89
SMBData
SMBCLK
ALERT
SMBus
Master
*Note: 2.2nF capacitor must be placed as close as possible to D+ and D- pins of the LM89.
10.2.1 Design Requirements
10.2.1.1 Diode Nonideality
10.2.1.1.1
Diode Nonideality Factor Effect On Accuracy
When a transistor is connected as a diode, the following relationship holds for variables VBE, T and If:
24
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
Typical Application (continued)
Vbe
KVt
IF = IS e
-1
where
Vt = kqT
(1)
where
q = 1.6×10−19 Coulombs (the electron charge),
T = Absolute Temperature in Kelvin
k = 1.38×10−23joules/K (Boltzmann's constant),
η is the nonideality factor of the process the diode is manufactured on,
IS = Saturation Current and is process dependent,
If= Forward Current through the base emitter junction
VBE = Base Emitter Voltage drop
•
•
•
•
•
•
•
(2)
In the active region, the -1 term is negligible and may be eliminated, yielding the following equation
Vbe
KVt
IF = IS e
(3)
In the above equation, η and IS are dependant upon the process that was used in the fabrication of the particular
diode. By forcing two currents with a very controlled ratio (N) and measuring the resulting voltage difference, it is
possible to eliminate the IS term. Solving for the forward voltage difference yields the relationship:
Vbe = K kqT ln (N)
(4)
The voltage seen by the LM89 also includes the IFRS voltage drop of the series resistance. The nonideality
factor, η, is the only other parameter not accounted for and depends on the diode that is used for measurement.
Since ΔVBE is proportional to both η and T, the variations in η cannot be distinguished from variations in
temperature. Since the nonideality factor is not controlled by the temperature sensor, it will directly add to the
inaccuracy of the sensor. For the Pentium 4 and Mobile Pentium Processor-M Intel specifies a ±0.1% variation in
η from part to part. As an example, assume a temperature sensor has an accuracy specification of ±1°C at room
temperature of 25 °C and the process used to manufacture the diode has a nonideality variation of ±0.1%. The
resulting accuracy of the temperature sensor at room temperature will be:
TACC = ± 1°C + (±0.1% of 298 °K) = ±1.4 °C
(5)
The additional inaccuracy in the temperature measurement caused by η, can be eliminated if each temperature
sensor is calibrated with the remote diode that it will be paired with.
η, nonideality
Processor Family
Pentium III CPUID 67h
MIN
TYP
MAX
1
1.0065
1.0125
Pentium III CPUID 68h/PGA370Socket/Celeron
1.0057
1.008
1.0125
Pentium 4, 423 pin
0.9933
1.0045
1.0368
Pentium 4, 478 pin
0.9933
1.0045
1.0368
0.13 micron, Pentium 4
1.0011
1.0021
1.0030
MMBT3904
AMD Athlon MP model 6
1.003
1.002
1.008
1.016
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
25
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
10.2.2 Detailed Design Procedure
10.2.2.1 Compensating For Diode Nonideality
In order to compensate for the errors introduced by nonideality, the temperature sensor is calibrated for a
particular processor. The LM89 is calibrated for the nonideality of a 0.13 micron, Mobile Pentium 4, 1.0021.
When a temperature sensor calibrated for a particular processor type is used with a different processor type or a
given processor type has a nonideality that strays from the typical, errors are introduced.
Temperature errors associated with nonideality may be reduced in a specific temperature range of concern
through use of the offset registers (11h and 12h).
10.2.3 Application Curves
LM89 is connected to diode-connected MMBT3904.
2N3904 and LM89 junction temperatures are equivalent during
test.
Figure 16. Local Temperature Accuracy
Figure 17. Remote Temperature Accuracy
10.3 Do's and Don'ts
Noise coupling into the digital lines greater than 400mVp-p (typical hysteresis) and undershoot less than 500mV
below GND, may prevent successful SMBus communication with the LM89. SMBus no acknowledge is the most
common symptom, causing unnecessary traffic on the bus. Although the SMBus maximum frequency of
communication is rather low (100kHz max), care still needs to be taken to ensure proper termination within a
system with multiple parts on the bus and long printed circuit board traces. An RC lowpass filter with a 3db
corner frequency of about 40MHz is included on the LM89's SMBCLK input. Additional resistance can be added
in series with the SMBData and SMBCLK lines to further help filter noise and ringing. Minimize noise coupling by
keeping digital traces out of switching power supply areas as well as ensuring that digital lines containing high
speed data communications cross at right angles to the SMBData and SMBCLK lines.
26
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
11 Power Supply Recommendations
VDD should be bypassed with a 0.1µF capacitor in parallel with 100pF. The 100pF capacitor should be placed as
close as possible to the power supply pin. A bulk capacitance of approximately 10µF needs to be in the near
vicinity of the LM89. The ideal place to connect the LM89's GND pin is as close as possible to the Processors
GND associated with the sense diode.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
27
LM89
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
www.ti.com
12 Layout
12.1 Layout Guidelines
In a noisy environment, such as a processor mother board, layout considerations are very critical. Noise induced
on traces running between the remote temperature diode sensor and the LM89 can cause temperature
conversion errors. Keep in mind that the signal level the LM89 is trying to measure is in microvolts. The following
guidelines should be followed:
1. VDD should be bypassed with a 0.1µF capacitor in parallel with 100pF. The 100pF capacitor should be placed
as close as possible to the power supply pin. A bulk capacitance of approximately 10µF needs to be in the
near vicinity of the LM89.
2. A 2.2nF diode bypass capacitor is required to filter high frequency noise. Place the 2.2nF capacitor as close
as possible to the LM89's D+ and D− pins. Make sure the traces to the 2.2nF capacitor are matched.
3. Ideally, the LM89 should be placed within 10cm of the Processor diode pins with the traces being as straight,
short and identical as possible. Trace resistance of 1Ω can cause as much as 1°C of error. This error can be
compensated by using the Remote Temperature Offset Registers, since the value placed in these registers
will automatically be subtracted from or added to the remote temperature reading.
4. Diode traces should be surrounded by a GND guard ring to either side, above and below if possible. This
GND guard should not be between the D+ and D− lines. In the event that noise does couple to the diode
lines it would be ideal if it is coupled common mode. That is equally to the D+ and D− lines.
5. Avoid routing diode traces in close proximity to power supply switching or filtering inductors.
6. Avoid running diode traces close to or parallel to high speed digital and bus lines. Diode traces should be
kept at least 2cm apart from the high speed digital traces.
7. If it is necessary to cross high speed digital traces, the diode traces and the high speed digital traces should
cross at a 90 degree angle.
8. The ideal place to connect the LM89's GND pin is as close as possible to the Processors GND associated
with the sense diode.
9. Leakage current between D+ and GND should be kept to a minimum. One nanoampere of leakage can
cause as much as 1°C of error in the diode temperature reading. Keeping the printed circuit board as clean
as possible will minimize leakage current.
12.2 Layout Example
Figure 18. Ideal Diode Trace Layout
28
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
LM89
www.ti.com
SNIS128D – AUGUST 2002 – REVISED JUNE 2014
13 Device and Documentation Support
13.1 Trademarks
All trademarks are the property of their respective owners.
13.2 Electrostatic Discharge Caution
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
13.3 Glossary
SLYZ022 — TI Glossary.
This glossary lists and explains terms, acronyms, and definitions.
14 Mechanical, Packaging, and Orderable Information
The following pages include mechanical, packaging, and orderable information. This information is the most
current data available for the designated devices. This data is subject to change without notice and revision of
this document. For browser-based versions of this data sheet, refer to the left-hand navigation.
Submit Documentation Feedback
Copyright © 2002–2014, Texas Instruments Incorporated
Product Folder Links: LM89
29
PACKAGE OPTION ADDENDUM
www.ti.com
1-Nov-2015
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
MSL Peak Temp
(2)
(6)
(3)
Op Temp (°C)
Device Marking
(4/5)
LM89-1CIMM/NOPB
ACTIVE
VSSOP
DGK
8
1000
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
0 to 125
T19C
LM89-1CIMMX/NOPB
ACTIVE
VSSOP
DGK
8
3500
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
0 to 125
T19C
LM89-1DIMM/NOPB
ACTIVE
VSSOP
DGK
8
1000
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
0 to 125
T19D
LM89-1DIMMX/NOPB
ACTIVE
VSSOP
DGK
8
3500
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
0 to 125
T19D
LM89CIMM/NOPB
ACTIVE
VSSOP
DGK
8
1000
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
0 to 125
T15C
LM89CIMMX/NOPB
ACTIVE
VSSOP
DGK
8
3500
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
0 to 125
T15C
LM89CIMX
NRND
SOIC
D
8
TBD
Call TI
Call TI
0 to 125
LM89
CIM
LM89CIMX/NOPB
ACTIVE
SOIC
D
8
Green (RoHS
& no Sb/Br)
CU SN
Level-1-260C-UNLIM
0 to 125
LM89
CIM
2500
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Addendum-Page 1
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
(4)
1-Nov-2015
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5)
Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6)
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
2-Sep-2015
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
LM89-1CIMM/NOPB
VSSOP
DGK
8
1000
178.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
LM89-1CIMMX/NOPB
VSSOP
DGK
8
3500
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
LM89-1DIMM/NOPB
VSSOP
DGK
8
1000
178.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
LM89-1DIMMX/NOPB
VSSOP
DGK
8
3500
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
LM89CIMM/NOPB
VSSOP
DGK
8
1000
178.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
LM89CIMMX/NOPB
VSSOP
DGK
8
3500
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
LM89CIMX/NOPB
SOIC
D
8
2500
330.0
12.4
6.5
5.4
2.0
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
2-Sep-2015
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
LM89-1CIMM/NOPB
VSSOP
DGK
8
1000
210.0
185.0
35.0
LM89-1CIMMX/NOPB
VSSOP
DGK
8
3500
367.0
367.0
35.0
LM89-1DIMM/NOPB
VSSOP
DGK
8
1000
210.0
185.0
35.0
LM89-1DIMMX/NOPB
VSSOP
DGK
8
3500
367.0
367.0
35.0
LM89CIMM/NOPB
VSSOP
DGK
8
1000
210.0
185.0
35.0
LM89CIMMX/NOPB
VSSOP
DGK
8
3500
367.0
367.0
35.0
LM89CIMX/NOPB
SOIC
D
8
2500
367.0
367.0
35.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2015, Texas Instruments Incorporated