ASC DS-0032 Amplified pressure sensor Datasheet

Amplified Very Low Pressure Sensors
AMPLIFIED Pressure Sensors
Features
• 0.25 and 0.50 In H2O Pressure Ranges
• Ratiometric 4V Output
• Temperature Compensated
• Calibrated Zero and Span
Applications
General Description
The Amplified line of low pressure sensor is based upon a proprietary technology to reduce all output offset or common mode errors.
This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change in
all sensors
• Medical Breathing
• HVAC
conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure
to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.
2.54
0.100
(Typ)
8.74
0.344
CL
Vs
1.27
0.050
0.020" x 0.010" Pin
0.30" minimum length
Pin 1 Identifier
5.33
0.210
Port B
Gnd
3.18
R0.125
pin 1: Vsupply
12.19
0.480
13.97
0.550
20.32
0.800
pin 2: Common
21.59
0.850
pin 3: Voutput
pin 4: do not connect
All Sensors
DS-0032 Rev B
Vout
+
27.43
1.080
3.56
0.140
Port A
10.67
0.420
10.67
0.420
3.18
0.125
Port 0.179"/0.189"
Equivalent Circuit
a 16035 Vineyard Blvd. Morgan Hill, CA 95037
Physical Dimensions
p 408 225 4314
f 408 225 2079
is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
e www.allsensors.com
temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to
Pressure Sensor Ratings
Supply Voltage, Vs
Common-mode pressure
Environmental Specifications
+4.5 to +5.5 Vdc
Temperature Ranges
-10 to +10 psig
Compensated
270°C
Lead Temperature, max (soldering 2-4 sec.)
5 to 50° C
Operating
-25 to 85° C
Storage
-40 to 125° C
Humidity Limits
0 to 95% RH
(non condensing)
Standard Pressure Ranges
Device
Operating Range
Proof Pressure
Burst Pressure
Nominal Span (5)
0.25 INCH-D-4V
±0.25 inH2O
40 inH2O
80 inH2O
±2.0 V
0.25 INCH-G-4V
0.25 inH2O
40 inH2O
80 inH2O
4.0 V
0.5 INCH-D-4V
±0.5 inH2O
40 inH2O
80 inH2O
±2.0 V
0.5 INCH-G-4V
0.5 inH2O
40 inH2O
80 inH2O
4.0 V
Performance Characteristics for: 0.25 INCH-D-4V
Parameter, note 1
note
1
Minimum
Nominal
Maximum
Units
Output Span note 5
±1.90
±2.0
±2.1
V
Offset Voltage @ zero differential pressure
2.15
2.25
2.35
V
Offset Temperature Shift, note 2
-
-
±60
mV
Offset Warm-up Shift, note 3
-
±20
-
mV
Offset Position Sensitivity (±1g)
-
±20
-
mV
Offset Long Term Drift (one year)
-
±20
-
mV
Linearity, hysteresis error, note 4
-
0.05
0.25
%FSS
Span Temperature Shift, note 2
-
-
±3
%FSS
Minimum
Nominal
Maximum
Units
Output Span note 5
3.9
4.0
4.1
V
Offset Voltage @ zero gage pressure
0.15
0.25
0.35
V
Offset Temperature Shift, note 2
-
-
±60
mV
Offset Warm-up Shift, note 3
-
±20
Offset Position Sensitivity (±1g)
-
±20
-
mV
Offset Long Term Drift (one year)
-
±20
-
mV
Linearity, hysteresis error, note 4
-
0.05
0.25
%FSS
Span Temperature Shift, note 2
-
-
±3
%FSS
Performance Characteristics for: 0.25 INCH-G-4V note 1
Parameter, note 1
mV
Amplified Very Low Pressure Sensors
Nominal
Maximum
Units
±1.90
±2.0
±2.1
V
Offset Voltage @ zero differential pressure
2.15
2.25
2.35
V
Offset Temperature Shift, note 2
-
-
±60
mV
Offset Warm-up Shift, note 3
-
±20
-
mV
Offset Position Sensitivity (±1g)
-
±20
-
mV
Offset Long Term Drift (one year)
-
±20
-
mV
Linearity, hysteresis error, note 4
-
0.05
0.25
%FSS
Span Temperature Shift, note 2
-
-
±3
%FSS
Minimum
Nominal
Maximum
Units
Output Span note 5
3.9
4.0
4.1
V
Offset Voltage @ zero gage pressure
0.15
0.25
0.35
V
Offset Temperature Shift, note 2
-
-
±60
mV
Offset Warm-up Shift, note 3
-
±20
-
mV
Offset Position Sensitivity (±1g)
-
±20
-
mV
Offset Long Term Drift (one year)
-
±20
-
mV
Linearity, hysteresis error, note 4
-
0.05
0.25
%FSS
Span Temperature Shift, note 2
-
-
±3
%FSS
Performance Characteristics for: 0.5 INCH-G-4V note 1
Specification Notes
note
1: All parameters are measured at 5.0 volt excitation, for the nominal full scale pressure and room temperature unless otherwise specified.
with positive pressure applied to
2:
3:
note 4:
note 5:
note
note
Port B.
Pressure measurements are
Shift is relative to 25°C.
Shift is within the first hour of excitation applied to the device.
Measured at one-half full scale rated pressure using best straight line curve fit.
The span is the algebraic difference between full scale output voltage and the offset voltage.
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
All Sensors
DS-0032 Rev B
a 16035 Vineyard Blvd. Morgan Hill, CA 95037
p 408 225 4314
Parameter, note 1
e www.allsensors.com
Minimum
Output Span note 5
f 408 225 2079
Parameter, note 1
all sensors
Performance Characteristics for: 0.5 INCH-D-4V note 1