Panasonic JQ1a-5V-F 1a/1c 5a/10a small power relay Datasheet

JQ
VDE
1a/1c 5A/10A small power
relays
RoHS compliant
JQ RELAYS
FEATURES
TYPICAL APPLICATIONS
• High electrical noise immunity
• High switching capacity in a compact
package
• High sensitivity: 200 mW (1a),
400 mW (1c)
• High surge voltage: 8,000 V between
contacts and coil
• UL, CSA, VDE, SEMKO approved and
TÜV available
• Class B coil insulation type also
available.
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
ORDERING INFORMATION
JQ
F
Contact arrangement
1a: 1 Form A
1 : 1 Form C
Contact capacity
Nil: Standard (5A)
P: High capacity (10A)
Coil insulation class
Nil: Class E coil insulation
B: Class B coil insulation (UL)
Nominal coil voltage (DC)
5V, 6V, 9V, 12V, 18V, 24V, 48V*
Contact material
F: AgSnO2 type
Certified by UL, CSA, VDE and SEMKO
Note: *Available only for 1 Form C type
TYPES
1) Standard type
Standard type
Nominal coil voltage
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC
1 Form A
Part No.
JQ1a-5V-F
JQ1a-6V-F
JQ1a-9V-F
JQ1a-12V-F
JQ1a-18V-F
JQ1a-24V-F
–
High capacity type
1 Form C
Part No.
JQ1-5V-F
JQ1-6V-F
JQ1-9V-F
JQ1-12V-F
JQ1-18V-F
JQ1-24V-F
JQ1-48V-F
1 Form A
Part No.
JQ1aP-5V-F
JQ1aP-6V-F
JQ1aP-9V-F
JQ1aP-12V-F
JQ1aP-18V-F
JQ1aP-24V-F
–
1 Form C
Part No.
JQ1P-5V-F
JQ1P-6V-F
JQ1P-9V-F
JQ1P-12V-F
JQ1P-18V-F
JQ1P-24V-F
JQ1P-48V-F
Standard packing: Carton 100 pcs., Case 500 pcs.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB185E 201202-T
JQ
RATING
1. Coil data
Contact
Nominal coil
arrangement
voltage
5V DC
1 Form A
1 Form C
6V DC
9V DC
12V DC
18V DC
24V DC
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
48V DC
Pick-up voltage
(at 20°C 68°F)
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)
Drop-out
voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
5%V or more of
nominal voltage
(Initial)
40.0mA
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
125
180
405
720
1,620
2,880
5%V or more of
nominal voltage
(Initial)
80 mA
66.7mA
44.4mA
33.3mA
22.2mA
16.7mA
8.3mA
62.5Ω
90 Ω
202.5Ω
360 Ω
810 Ω
1,440 Ω
5,760 Ω
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Ω
Ω
Ω
Ω
Ω
Ω
Max. applied voltage
180% of nominal voltage
(at 20°C 68°F)
200mW
130% of nominal voltage
(at 70°C 158°F)
[When using relays at
85°C 185°F, see Notes*4]
150% of nominal voltage
(at 20°C 68°F)
400mW
110% of nominal voltage
(at 70°C 158°F)
[When using relays at
85°C 185°F, see Notes*4]
2. Specifications
Characteristics
Contact
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Rating
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (reference value)*1
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Between open contacts
Between contact and coil
Temperature rise (coil)
Electrical
characteristics
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Conditions for operation, transport and storage*3
Max. operating speed
Unit weight
Specifications
Standard type
High capacity type
1 Form C
1 Form A
1 Form C
Max. 100mΩ (By voltage drop 6 V DC 1 A)
AgSnO2 type
N.O. side:
N.O. side:
5 A 125 V AC,
10 A 125 V AC,
2 A 250 V AC,
5 A 250 V AC,
5 A 125 V AC,
10 A 125 V AC,
3 A 30 V AC
5 A 30 V AC
2 A 250 V AC,
5 A 250 V AC,
N.C. side:
N.C. side:
5 A 30 V DC
5 A 30 V DC
2 A 125 V AC,
3 A 125 V AC,
1 A 250 V AC,
2 A 250 V AC,
1 A 30 V DC
1 A 30 V DC
N.O. side:
N.O. side:
625 VA, 90 W
1,250 VA, 150 W
625 VA, 150 W
1,250 V AC, 150 W
N.C. side:
N.C. side:
250 VA, 30 W
500 V AC, 30 W
250 V AC, 110 V DC (0.3A)
N.O.: 5 A, N.C.: 2 A
N.O.: 10 A, N.C.: 3 A
200 mW
400 mW
200 mW
400 mW
100 mA, 5 V DC
Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section.
1 Form A
1,000 Vrms for 1 min.
750 Vrms for 1 min.
1,000 Vrms for 1 min.
750 Vrms for 1 min.
4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 45°C 113°F
Max. 45°C 113°F
(By resistive method, nominal coil voltage
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
applied to the coil; contact carrying current:
5A, at 70°C 158°F)
10A, at 70°C 158°F)
8,000 V
Max. 20 ms (excluding contact bounce time.)
Max. 10 ms (excluding contact bounce time) (Without diode)
294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 107
Ambient temperature: –40°C to +70°C –40°F to +158°F (class E insulation),
–40°C to +85°C –40°F to +185°F*4 (class B insulation)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 7 g .25 oz
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
ASCTB185E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
JQ
3. Expected electrical life
Type
Switching capacity
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
3 A 30 V DC
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
1 Form A
Standard type
N.O.
1 Form C
N.C.
1 Form A
N.O.
High capacity type
1 Form C
N.C.
No. of operations
5×104
2×105
2×105
105
5×104
2×105
2×105
105
2×105
2×105
105
5×104
5×104
105
5×104
5×104
105
2×105
2×105
105
REFERENCE DATA
1.-(1) Max. switching capacity (1 Form A type)
1.-(2) Max. switching capacity (1 Form C type)
100
Contact current, A
Contact current, A
100
AC resistive load (High capacity type)
10
5
100 250
10
5
3
2
AC resistive load
1 (High capacity type)
N.C. side
AC resistive load
(Standard type)
N.C. side
1 AC resistive load (Standard type)
10
AC resistive load
(High capacity type) N.O. side
AC resistive load
(Standard type) N.O. side
10
1,000
100 250
1,000
Contact voltage, V
Contact voltage, V
Standard type
2. Life curve
3.-(1) Operate & release time (1 Form A type)
3.-(2) Operate & release time (1 Form C type)
Ambient temperature: room temperature
Tested sample: JQ1a-12V-F, 25 pcs.
Tested sample: JQ1-24V-F, 25 pcs.
125V AC
resistive load
10
250V AC
resistive load
8
6
Operate time
4
2
Release time
1
0
1
2
3
4
5
Contact current, A
Panasonic Corporation
0
80
100
120
Max.
Max.
Min.
Min.
8
6
Operate time
4
Max.
Max.
Min.
Min.
2
Release time
150
Coil applied voltage, %V
Automation Controls Business Unit
Operate & release time, ms
Operate & release time, ms
Life, ×104
100
0
80
100
120
150
Coil applied voltage, %V
industrial.panasonic.com/ac/e/
ASCTB185E 201202-T
JQ
4.-(1) Coil temperature rise (1 Form A type)
4.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
70
40
Temperature rise, °C
Temperature rise, °C
50
5 A at 70°C
5 A at 85°C
30
20
3 A at 70°C
60
5 A at 70°C
50
3 A at 70°C
40
5 A at 85°C
30
3 A at 85°C
20
3 A at 85°C
10
10
0
0
100 110 120 130 140 150 160 170 180 190
100
110
120
Coil applied voltage, %V
130
140
150
160
Coil applied voltage, %V
5.-(1) Ambient temperature characteristics
(1 Form A type)
5.-(2) Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1a-24V-F
Contact carrying current: 3 A, 5 A
Tested sample: JQ1-24V-F
Contact carrying current: 3 A, 5 A
400
300
1
2
200
3
5
6
4
Coil applied voltage, %V
Coil applied voltage, %V
400
100
300
1
2
200
3
4
5
100
6
7
0
20
30
40
50
60
70
80
0
90
20
30
7
40
Ambient temperature, °C
50
60
70
80
90
Ambient temperature, °C
1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 3 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 3 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
7 Pick-up voltage
High capacity type
1. Life curve
2.-(1) Operate & release time (1 Form A type)
2.-(2) Operate & release time (1 Form C type)
Ambient temperature: room temperature
Tested sample: JQ1aP-12V-F, 25 pcs.
Tested sample: JQ1P-12V-F, 25 pcs.
250V AC resistive load
1
0
2
4
8
6
Operate time
4
Max.
Min.
Max.
Min.
2
6
8
0
10
Release time
80
100
Contact current, A
120
150
3.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
60
Operate time
4
Max.
Max.
Min.
Min.
2
80
100
120
150
Coil applied voltage, %V
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
60
6
Release time
3.-(1) Coil temperature rise (1 Form A type)
70
8
0
Coil applied voltage, %V
70
Operate & release time, ms
125V AC resistive load
10
Operate & release time, ms
Life, ×104
100
10 A at 85°C
50
10 A at 70°C
40
5 A at 70°C
30
Temperature rise, °C
Temperature rise, °C
10 A at 85°C
10 A at 70°C
50
5 A at 70°C
40
5 A at 85°C
30
5 A at 85°C
20
20
10
10
0
100
120
140
160
180
0
Coil applied voltage, %V
ASCTB185E 201202-T
Panasonic Corporation
100
110
120
130
140
150
160
Coil applied voltage, %V
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
JQ
4.-(1) Ambient temperature characteristics
(1 Form A type)
4.-(2) Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1aP-24V-F
Contact carrying current: 5 A, 10 A
Tested sample: JQ1P-24V-F
Contact carrying current: 5 A, 10 A
400
1
Coil applied voltage, %V
Coil applied voltage, %V
400
2
300
200
3
5
4
300
1
2
200
3
4
5
100
100
6
0
1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 10 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 10 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
7 Pick-up voltage
20
30
6
7
40
50
60
70
80
90
0
20
30
Ambient temperature, °C
7
40
50
60
70
80
90
Ambient temperature, °C
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
1 Form A
1 Form A
10
.394
20
.787
Schematic (Bottom view)
1 Form C
COM
N.O.
Coil
COM
N.O.
Coil
15.6
.614
N.C.
0.4
.016
7.62
.300
4.2
.165
0.5 dia.
.020 dia.
10.16
.400
0.3
.012
7.62
.300
0.3
.012
7.62
.300
0.8
.031
1 Form C
1 Form A
10
.394
20
.787
10.16
.400
15.6
.614
PC board pattern (Bottom view)
1FormC
7.62
.300
4-1.3 dia.
4-.051 dia.
7.62
.300
0.4
.016
7.62
.300
4.2
.165
0.5 dia.
.020 dia.
7.62
.300
5-1.3 dia.
5-.051 dia.
7.62
.300
2.54
.100
10.16
.400
0.3
.012
5.08
.200
2.54
.100
0.3
.012
0.3
.012
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 5mm .197 inch:
Min. 5mm .197 inch:
Panasonic Corporation
10.16
.400
7.62
.300
0.8
.031
Tolerance: ±0.1 ±.004
General tolerance
±0.2 ±.008
±0.3 ±.012
±0.4 ±.016
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB185E 201202-T
JQ
SAFETY STANDARDS
Item
Standard type
(5A) 1 Form A
UL/C-UL (Recognized)
File No.
Contact rating
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
CSA (Certified)
File No.
Contact rating
File No.
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
40011435
VDE (Certified)
Contact rating
5A 250V AC (cosφ =0.4)
TÜV (Certified)
File No.
Rating
B 11 04
5A 250V AC (cosφ =0.4)
13461 296 5A 30V DC (0ms)
SEMKO (Certified)
File No.
Contact rating
817138
3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
Standard type
(5A) 1 Form C
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1/10HP 125V AC
1/6HP 277V AC
40011435
5A 250V AC (cosφ =0.4)
(N.O.)
3A 250V AC (cosφ =0.4)
(N.C.)
B 11 04
5A 250V AC (cosφ =0.4)
13461 296 5A 30V DC (0ms)
817138
3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
High capacity type
(10A) 1 Form A
E43028
LR26550
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
40011435
10A 250V AC (cosφ =0.4)
B 11 04
10A 250V AC (cosφ =0.4)
13461 296 5A 30V DC (0ms)
817138
5(3)A 250V AC
5A 30V DC
High capacity type
(10A) 1 Form C
E43028
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
LR26550
10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1/6HP 125V AC
1/6HP 277V AC
40011435
(N.O.)
10A 250V AC (cosφ =0.4)
(N.C.)
3A 250V AC (cosφ =0.4)
B 11 04
10A 250V AC (cosφ =0.4)
13461 296 5A 30V DC (0ms)
817138
5(3)A 250V AC
5A 30V DC
NOTES
Note about relay installation orientation
Top
When installing with the relay terminals parallel to the ground, the contact terminals at
the bottom and the coil terminals at the top, component friction will occur after
numerous switching actions or due to vibration in the non-excitation state.
Since this may cause the relay to stop functioning when the pick-up voltage increases
even if the nominal voltage is applied, please do not install using this orientation.
Bottom
For Cautions for Use.
ASCTB185E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic:
JQ1-12V JQ1P-24V JQ1AP-B-12V JQ1P-B-24V-F JQ1P-48V-F JQ1AP-B-24V-F JQ1-B-12V-F JQ1APE-24V-H12
JQ1-5V JQ1A-5V JQ1A-12V JQ1-24V JQ1A-24V JQ1P-5V JQ1AP-12V JQ1P-12V JQ1AP-24V JQ1A-5V-F
JQ1AP-12V-F JQ1AP-24V-F JQ1AP-5V-F JQ1-5V-F JQ1A-12V-F JQ1P-5V-F JQ1-24V-F JQ1-12V-F JQ1P-12V-F
JQ1P-24V-F JQ1A-24V-F JQ1AP-5V JQ1-18V JQ1-18V-F JQ1-3V JQ1-48V JQ1-48V-F JQ1-6V JQ1-6V-F
JQ1-9V JQ1-9V-F JQ1A-18V JQ1A-18V-F JQ1A-3V JQ1A-6V JQ1A-6V-F JQ1A-9V JQ1A-9V-F JQ1A-B-12V
JQ1A-B-12V-F JQ1A-B-18V JQ1A-B-18V-F JQ1A-B-24V JQ1A-B-24V-F JQ1A-B-5V JQ1A-B-5V-F JQ1A-B-6V
JQ1A-B-6V-F JQ1A-B-9V JQ1A-B-9V-F JQ1A-F-24V JQ1AP-18V JQ1AP-18V-F JQ1AP-3V JQ1AP-6V JQ1AP-6VF JQ1AP-9V JQ1AP-9V-F JQ1AP-B-12V-F JQ1AP-B-12V-Y3 JQ1AP-B-18V JQ1AP-B-18V-F JQ1AP-B-24V
JQ1AP-B-24V-Y3 JQ1AP-B-5V JQ1AP-B-5V-F JQ1AP-B-6V JQ1AP-B-6V-F JQ1AP-B-9V JQ1AP-B-9V-F JQ1APB-9V-Y3 JQ1AP-F-12V JQ1AP-F-12V-F JQ1APF-18V JQ1AP-F-24V-F JQ1APF-B-12V-F JQ1APF-F-12V JQ1APFF-12V-F JQ1APF-F-24V-F JQ1APF-F-5V-F JQ1APF-F-9V-F JQ1-B-12V JQ1-B-18V JQ1-B-18V-F JQ1-B-24V
JQ1-B-24V-F JQ1-B-48V JQ1-B-48V-F JQ1-B-5V JQ1-B-5V-F JQ1-B-6V JQ1-B-6V-F
Similar pages