FR2A THRU FR2M SURFACE MOUNT FAST RECOVERY RECTIFIER Reverse Voltage - 50 to 1000 Volts Forward Current - 2.0 Amperes DO-214AA FEATURES The plastic package carries Underwriters Laboratory Flammability Classification 94V-0 For surface mounted applications Fast switching for high efficiency Low reverse leakage Built-in strain relief,ideal for automated placement High forward surge current capability High temperature soldering guaranteed: 250 C/10 seconds at terminals 0.155(3.94) 0.130(3.30) 0.086 (2.20) 0.077 (1.95) 0.180(4.57) 0.160(4.06) 0.012(0.305) 0.006(0.152) MECHANICAL DATA 0.122(3.12) 0.110(2.82) 0.060(1.52) 0.030(0.76) Case: JEDEC DO-214AC molded plastic body Terminals: Solder plated , solderable per MIL-STD-750, Method 2026 Polarity: Color band denotes cathode end Mounting Position: Any Weight:0.005 ounce, 0.138 grams 0.008(0.203)MAX. 0.220(5.59) 0.205(5.21) Dimensions in inches and (millimeters) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 C ambient temperature unless otherwise specified. Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%. SYMBOLS Maximum repetitive peak reverse voltage Maximum RMS voltage Maximum DC blocking voltage Maximum average forward rectified current at TL=90 C Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method) Maximum instantaneous forward voltage at 2.0A Maximum DC reverse current TA=25 C at rated DC blocking voltage TA=100 C Maximum reverse recovery time (NOTE 1) Typical junction capacitance (NOTE 2) Typical thermal resistance (NOTE 3) Operating junction and storage temperature range VRRM VRMS VDC FR2A FR2B FR2D 50 35 50 100 70 100 200 140 200 FR2G FR2J FR2K FR2M UNITS 400 280 400 800 560 800 VOLTS VOLTS VOLTS 600 420 600 1000 700 1000 I(AV) 2.0 Amps IFSM 50.0 Amps VF 1.3 Volts IR 5.0 50.0 uA trr 150 CJ RqJA TJ,TSTG Note:1.Reverse recovery condition IF=0.5A,IR=1.0A,Irr=0.25A 2.Measured at 1MHz and applied reverse voltage of 4.0V D.C. 3.P.C.B. mounted with 0.2x0.2”(5.0x5.0mm) copper pad areas www.shunyegroup.com 250 50.0 20.0 -65 to +150 500 ns pF C/W C RATINGS AND CHARACTERISTIC CURVES FR2A THRU FR2M AVERAGE FORWARD RECTIFIED CURRENT, AMPERES FIG. 1- FORWARD CURRENT DERATING CURVE 1.6 1.2 Single Phase Half Wave 60Hz Resistive or inductive Load 0.8 0.4 0 0 25 50 FIG. 2-MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT 50 £PEAK FORWARD SURGE CURRENT, AMPERES 2.0 75 100 125 150 40 30 20 10 175 0 8.3ms SINGLE HALF SINE-WAVE (JEDEC Method) 1 10 AMBIENT TEMPERATURE, C FIG. 4-TYPICAL REVERSE CHARACTERISTICS FIG. 3-TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 1,000 10 1 TJ=25 C PULSE WIDTH=300 ms 1%DUTY CYCLE 0.1 0.01 0.6 0.8 1.0 1.2 1.4 1.5 INSTANTANEOUS REVERSE CURRENT, MICROAMPERES INSTANTANEOUS FORWARD CURRENT,AMPERES 20 100 10 TJ=100 C 1 0.1 TJ=25 C 0.01 INSTANTANEOUS FORWARD VOLEAGE, VOLTS 20 40 60 80 TJ=25 C 10 100 10 1 0.1 0.01 0.1 1 10 1 0.1 1.0 10 100 FIG. 6-TYPICAL TRANSIENT THERMAL IMPEDANCE TRANSIENT THERMAL IMPEDANCE, C/W FIG. 5-TYPICAL JUNCTION CAPACITANCE 100 0 PERCENT OF PEAK REVERSE VOLTAGE,% 200 JUNCTION CAPACITANCE, pF 100 NUMBER OF CYCLES AT 60 Hz 100 REVERSE VOLTAGE,VOLTS www.shunyegroup.com t,PULSE DURATION,sec. 100