DEN Suppression Chokes www.schurter.com/pg81_82 Low frequency ground wire choke, fully potted resign Description Applications Standards References - Ground wire chokes (earth line chokes) - Wire leads - Fully potted resign - Separating the main earth line to periphery devices - This type of chokes permits the building of a system free of ground wire loops - EN 60938 General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check Technical Data Rated Current Rated inductance Power Operating Frequency Terminal technic Material: Housing Sealing Compound 16 - 25 A @ Ta 40 °C 0.02 - 4 mH < 5 MHz Wire leads UL 94V-0 UL 94V-0 Isolation Voltage Climatic Category Allowable Operation Temp. Dimensions Case 25 2 kV eff., winding to ambient 25/100/21 acc. to IEC 60068-1 -25 °C to 100 °C Case 40 40 2 1) 160 10 4.8 M3 1) 25.5 25.5 150 1mm2 32 M2.5 40 33 M3 25.5 30.8 Ø8 1 mm 32 M2.5 10 0.8 3.3 1) yellow/green Variants In [A] Ln [mH] Rcu [mΩ] fRES [MHz] Weight [g] Packing unit [pcs.] Order Number 16 4 27 0.3 42 50 DEN-25-0001 25 4 10.5 0.3 38 50 DEN-40-0001 The specifications, descriptions and illustrations indicated in this document are based on EMC Products current information. All content is subject to modifications and amendments.