Terminal Relay G6D-F4B/G3DZ-F4B Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent from one another. Short Bar ensures easy connection of common and adjacent terminals. Provided with a terminal cover that prevents electric-shock accidents. Relay and MOS FET relay models are available. LED operation indicator. Built-in diode absorbs coil surge. Mounts either on DIN track or screws. Tool for easy mounting or removal of Relays provided. Ordering Information Model Number Legend: G6D/G3DZ-jj 1 1. 2 Terminal Form F: Flat type Output Relay e ay ou output u 2. Contact configuration SPST-NO S S O 4 Terminals Phillipss head ead screw sc e t terminal i l Power o e MOS OS FET relay e ay output t t Note: Number of Relays Mounted 4B: 4 Rated coil voltage Model G6D-F4B G6 12 VDC 24 VDC G3DZ-F4B G3 12 VDC 24 VDC When ordering add the rated coil voltage to the model number. Example: G6D-F4B 24 VDC Rated coil voltage Accessories (Order Separately) Replacement Relays Applicable Terminal Relay G6D-F4B G6 Rated voltage Model G6D-1A (see note) G6 o e) 12 VDC 24 VDC G6D-1A-AP (see note) G6 o e) 12 VDC 24 VDC G3DZ-F4B G3 G3DZ-2R6PL G3 6 12 VDC 24 VDC Note: Error rate (P level) for the G6D-1A is 5 V at 10 mA and that for the G6D-1A-AP is 5 V at 1 mA. Short Bar Applicable Terminal Relay G6D-F4B Model G6D-4-SB G3DZ-F4B 1 G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B Specifications Ratings Coil Ratings (per G6D Relay) Rated voltage Rated current Coil resistance 12 VDC 18.7 mA 720 Ω 24 VDC 10.5 mA 2,880 Ω Note: Must operate voltage 70% 0% max. a ( (see note t 1) Must release voltage 10% 0% min. Max. voltage 130% 30% Power consumption Approx. o 200 00 mW 1. The must operate voltage is 75% or less of the rated voltage if the Relay is mounted upside down. 2. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±10%. 3. Operating characteristics were measured at a coil temperature of 23°C. 4. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is no continuous allowance. 5. The rated current includes the terminal’s LED current. Contact Ratings (per G6D Relay) Item Resistive load (cosφ = 1) Rated load 3 A at 250 VAC, 3 A at 30 VDC Rated carry current 5A Max. switching voltage 250 VAC, 30 VDC Max. switching current 5A Max. permissible capacity (reference value) 1,250 VA, 150 W Error rate (reference value) (see note) 5 VDC, 1 mA Note: This value is for a switching frequency of 120 times per minute. Power MOS FET Relay Specifications Input (per G3DZ Power MOS FET Relay) Rated voltage Operating voltage Must operate voltage level 12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 19.2 VDC max. Note: The rated current includes the terminal’s LED current. Output (per G3DZ Power MOS FET Relay) Load voltage 3 to 264 VAC 3 to 125 VDC 2 Load current 100 µ to 0.3 A Inrush current 6 A (10 ms) Must release voltage level 1 VDC C min. Input impedance Rated current 2 kΩ±20% 8.0 mA±20% 4 kΩ±20% 8.2 mA±20% G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B Characteristics G6D-F4B Item e Relay output Contact resistance (see note 2) 100 mΩ max. Must operate time (see note 3) 10 ms max. Release time (see note 3) 10 ms max. Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric e ec c s strength e g 2,000 VAC, 50/60 Hz for 1 min between coil and contacts. 750 VAC, 50/60 Hz for 1 min between contacts of same polarity 50 µs) Impulse withstand voltage (between coil and contacts) 4,000 V (1.2 Vibration resistance Destruction:10 to 55 Hz, 1.5-mm double amplitude Malfunction:10 to 55 Hz, 1.5-mm double amplitude Shock S oc resistance es s a ce Destruction:500 m/s2 Malfunction:100 m/s2 Life e expectancy e pec a cy Mechanical:20,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) 100,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 operations /hr) Ambient temperature Operating: –25°C to 55°C (with no icing) Storage: –25°C to 55°C (with no icing) Ambient humidity Operating: 45% to 85% Weight Approx. 65 g Note: 1. The above values are initial values. 2. Measurement condition: 1 A at 5 VDC 3. Ambient temperature condition: 23°C G3DZ-F4B Item e Power MOS FET relay output Must operate time 10 ms max. Release time 15 ms max. Output ON-resistance 2.4 Ω max. Leakage current at OFF state 10 µA max. (at 125 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between input and output terminals Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude Shock resistance 500 m/s2 Ambient temperature Operating: –25°C to 55°C (with no icing) Storage: –25°C to 55°C (with no icing) Ambient humidity Operating: 45% to 85% Weight Approx. 65 g 3 G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B Engineering Data G6D-F4B DC resistive load AC resistive load Life Expectancy Life expectance (x10 4 operations) Switching current (A) Max. Switching Capacity 250 VAC/30 VDC resistive load Switching current (A) Switching voltage (V) G3DZ-F4B Load current (A) Ambient temperature (°C) 4 Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) Inrush current (A. Peak) Load Current vs. Ambient Temperature Characteristics Energizing time (ms) G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B Dimensions Note: All units are in millimeters unless otherwise indicated. G6D-F4B G3DZ-F4B Mounting Dimensions 16, M3 Phillips head screws Two, 4 dia. or M3.5 holes Terminal Arrangement/ Internal Connections (Top View) Input side 68 max. Output side 31 max. 35 max. Note: Make sure that the polarity of the coil is correct. Accessories G6D-4-SB Short Bar Applicable model G6D-F4B Model G6D-4-SB G6 S G3DZ-F4B 5 G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B Precautions Wiring Coil Voltage Be sure to turn OFF the power when wiring the Unit and do not touch the charged terminals of the Unit. Otherwise, an electric shock may result. Do not apply overvoltage to the input terminals. Otherwise, the Unit may malfunction or burn. Make sure not to impose voltage exceeding the permissible voltage on the coil continuously. Do not connect any inductive load in parallel to the coil input as shown in the following example or power supply with a surge voltage. Otherwise, the surge absorption diode will be damaged. Relay Models Do Not Use the Following Circuit Do not connect the Unit to loads exceeding the rated switching capacity (switching voltage or current). Otherwise, faulty insulation, contact weld, or faulty contact of Relays, or damage to Relays may result, or the Relays may malfunction or burn. The life of Relays varies with the switching condition. Test the Relays under the actual operating conditions before using the Relays within the permissible switching frequency. The use of deteriorated Relays may result in the faulty insulation of the Relays or cause the Relays to burn. Do not use the Unit in locations with inflammable gas. Otherwise, a fire or explosion due to the heat of the Relays or sparks from the Relays may result when they are switched. SSR Output (Power MOS FET Relay Model) Do not connect the Unit to loads consuming a total current exceeding the rated output current of the Unit. Otherwise, the output element of the Unit may be damaged and a short or open-circuit malfunction may result. If the Unit is connected to a DC inductive load, connect a diode to the Unit to protect the Unit from counter-electromotive voltage, otherwise the counter-electromotive voltage may damage the output element and a short or open-circuit malfunction may result. Correct Use Mounting When mounting two or more Units, reduce the current and ON duty and provide an appropriate distance between the Units so that the ambient temperature will not exceed 55°C. Relay Replacement Use the Relay Removal Tool provided with the Unit to dismount a Relay. Be sure to turn OFF the power to the Unit before replacing a Relay. When mounting a Relay, insert the Relay vertically so that the relay terminals will come in contact with the socket contact pins properly. Do not mount Relays that are different to one another in voltage. Wiring Pay utmost attention not to make mistakes with the polarity of the input terminals. 6 Inductive load G6D coil Coil surge absorption diode Handling Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction. Make sure that all the Relays are properly mounted before use. Screw Tightening Torque Tighten each terminal screw to a torque of 0.78 to 1.18N S m. Tighten each mounting screw to a torque of 0.59 to 0.98 N S m. Installation Environment Do not install the Unit in the following locations. Otherwise, damage to the Unit may result or the Unit may malfunction. Locations with direct sunlight. Locations with an ambient temperature range not within –25°C to 55°C. Locations with rapid temperature changes resulting in condensation or locations with relative humidity ranges not within 45% to 85%. Locations with corrosive or inflammable gas. Locations with excessive dust, salinity, or metal powder. Locations with vibration or shock affecting the Unit. Locations with water, oil, or chemical sprayed on the Unit. Disassembly, Repair, and Modification Do not disassemble, repair, or modify the Unit. Otherwise, an electric shock may result or the Unit may malfunction. G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B 7 G6D-F4B/G3DZ-F4B G6D-F4B/G3DZ-F4B ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J115-E1-1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Industrial Control Components Division 28th Fl., Crystal Tower Bldg., 1-2-27, Shiromi, Chuo-ku, Osaka 540-6028 Japan Phone: (81)6-6949-6025 Fax: (81)6-6949-6029 8 Printed in Japan 0799-1M (0799) a