DIODE MODULE(F.R.D.) MDF(R)250A-L/M MDF(R)250A-L/M and MDR150-L/M are high speed(fast recovery)diode with flat mounting base which is designed for switching application of high power. 4-φ7 ] 45±0.4 62 φ8.5 24 4 19 8 (Applications) Switching Power Supply. Inverter Welding Power Supply MDF MDR 42 max [ 32 2 VRRM=200/300/400V ● Easy Construction with Anode (F)Type and Cathode(R)Type MDF:anode to terminal(normal polarity) MDR:cathode to terminal ● Reverse Recovery Time (trr)L Type: 450ns, M Type: 550ns ● High Reliability by Glass passivated Chips ● Non isolated type 45±0.4 62 ● IF (AV)250A 46 Unit:㎜ ■Maximum Ratings Symbol Item Ratings MDF(R)250A20L/M MDF(R)250A30L/M MDF(R)250A40L/M Unit VRRM Repetitive Peak Reverse Voltage 200 300 400 V VRSM Non-Repetitive Peak Reverse Voltage 240 360 480 V D.C. Reverse Voltage 160 240 320 V VR(DC) Symbol IF(AV) IF(RSM) Item Conditions Single phase, half wave, 180゜conduction, Tc:L/M 83゜/85℃ 250 A R.M.S. Forward Current Single phase, half wave, 180゜conduction, Tc:L/M 83゜/85℃ 390 A Surge Forward Current I2t I2t Value for one cycle of surge cureent Tj Tstg Unit Average Forward Current 1/ 2 IFMS Ratings cycle, 50/60HZ, peak value, non-repetitive A 4000/4500 84000 A2S Operating Junction Temperature −30 to +150 ℃ Storage Temperature −30 to +125 ℃ Mounting(M6) Recommended Value 2.5-3.9(25-40) 4.7(48) Terminal(M8) 11(115) N・m (㎏f・B) 170 g Mounting Torque Mass Recommended Value 8.8-10 (90-105) Typical Value ■Electrical Characteristics Symbol Item Conditions IRRM Repetitive Peak Reverse Current(max.) at VRRM, single phase, half wave, Tj=150℃ VFM Forward Voltage Drop(max.) Rth(j-c) Thermal Impedance(max.) trr Reverse Recovery Time(max.) SanRex Foward current 800A, Tj=25℃ Inst. measurement Unit 60 mA L 1.4 M 1.3 L 450 M 550 Junction to case Tj=25℃,IF=2A,ーdi/dt=20A/μs Ratings 0.2 V ℃/W ® 50 Seaview Blvd. Port Washington, NY 11050-4618 PH.(516)625-1313 FAX(516)625-8845 E-mail: [email protected] ns MDF(R)250A-L/M M Type Maximum Forward Characteristics 500 Power Dissipation(W) 5 2 Forward Current(A) Average Forward Current vs. Power Dissipation D.C. 400 103 Single Phase 300 5 Three Phase Six Phase 200 2 100 102 5 0 1. 0 0 0 2. 0 100 300 5000 4500 130 Per one element Tj=25℃ start 4000 110 400 Cycle Surge Current Rating (Non-Repetitive) Surge Forward Current(A) Allowable Case Temperature Tc(℃) 150 Average Forward Current vs. Allowable Case Temperature 200 Average Forward Current(A) Forward Voltage Drop(V) 3500 90 60Hz 3000 Single Phase 70 2500 Three Phase 50 2000 D.C. 0 50 100 150 200 250 300 350 400 1 2 5 10 20 100 50 Time(Cycles) Average Forward Current(A) 0. 4 Transient Thermal Impedance 0. 3 2 103 Junction to Case 0. 2 5 2 102 0. 1 5 10-2 2 5 10-1 2 Time t(sec) 5 100 2 500 D.C. 400 Single Phase Three Phase 300 Six Phase 200 100 0 0 100 200 300 Average Forward Current(A) 5 0 5 101 400 0. 5 1. 0 1. 5 2. 0 Forward Voltage Drop(V) Allowable Case Temperature Tc(℃) 0 10-3 2 Average Forward Current vs. Power Dissipation Power Dissipation Pav(W) Maximum Forward Characteristics 5 Forward Current(A) Transient Thermal Impedance θj-c(℃/W) L Type Average Forward Current vs. Allowable Case Temperature 150 130 110 90 70 50 0 Six Phase 100 Three Phase 200 Single Phase 300 D.C. 400 Average Forward Current(A) SanRex 50 Seaview Blvd. Port Washington, NY 11050-4618 PH.(516)625-1313 FAX(516)625-8845 E-mail: [email protected]