MPU-400E Series Single Output 400W Power Factor Corrected AC/DC Power Supplies Key Features: • Small 400W Supply • PFC to EN 61000-3-2 “D” • EN 60950 Approved (UL) • CE Certified • FCC Class B Emissions • Universal AC Input • Compact Case w/End Fan Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current, Full Load Conditions Universal Inrush Current, Cold Start Leakage Current Power Factor Correction Input Protection Min. 90 47 Typ. 90 VAC 6 110 VAC 220 VAC 264 VAC Meets EN 61000-3-2 Class D T8A/250V Fuse Max. 264 63 35 70 1.0 Units VAC Hz A A mA Output Parameter Output Voltage Adjustment Output Regulation, See Note 1 Hold Time Ripple & Noise (20 MHz), See Note 2 Overload Protection Over Voltage Protection Over Temperature Protection Temperature Coefficient Transient Recovery Time, See Note 4 Transient Response Deviation Overshoot/Undershoot Turn On Delay Output Short Circuit Conditions Min. By Trim Pot Typ. ±5.0 ±1.0 Max. 120 VAC, 80% Load 20 See Model Selection Guide Foldback Circuit, Autorecovery 110 140 >130% of Rated Output Voltage. Recycle AC Input. Autorecovery +110 ±0.04 2.5 50% Load Change 5 At Turn On/Off ±5.0 120 VAC 1 Continuous With Autorecovery Units % % mSec % ºC %/ºC mS % % S General Parameter Isolation Voltage, See Note 5 Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Primary - Core Fixed Min. 3,000 1,500 1,500 Typ. Max. Units VAC 23 kHz Interface Signals Power Supply On Green LED on the PCB An open collector output rated for 15V/5 mA sink current maximum. Goes high if a fan failure is detected Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. A TTL low signal inhibits the output. Hiccup mode. Fan Fail Power Good Signal MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Remote On/Off Environmental Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Operating Humidity Conditions Min. Typ. Max. Units 0 +25 +70 ºC 2.5%/ ºC from +50 ºC to + 70 ºC -20 +85 ºC See Model Selection Guide RH, Non-condensing 90 % Ambient Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 30ºC, Gnd Benign 100 kHours UL 60950, EN 60950 Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3 EN 6100-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD) Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Model Number Output Voltage (VDC) PreSet MPU-400S-12YE 12 VDC MPU-400S-24YE 24 VDC MPU-400S-48YE 48 VDC Range 10.0 - 13.8 21.0 - 26.0 43.0 - 50.0 Output Current (Max A) 33.33 16.67 8.33 Max. Output Power Ripple & Efficiency Noise (%) (W) (% p-p) 400 400 400 ±1% ±1% ±1% 85% 85% 85% Model Number Notes: 1. Output regulation includes line & load. 2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 3. A 1% minimum load is required to maintain regulation & ripple specifications. 4. Transient recovery is measured to within a 1% error band for a load step of 50% to 100%. 5. Isolation specifications are production HI-Pot tested for 3 seconds. 6. The full output range (see table) is covered in the safety agency certification. Standard models are factory set to the Preset voltage, but may be set to other levels within the range without affecting the agency certification. For more information, contact the factory. 7. Output power is given for the factory preset voltage. All models provide a peak power level of 700W for a maximum duration of 500 µS. For more information, contact the factory. 8. Each unit includes an input fuse (T8A/250V). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Mechanical Dimensions Models with other output voltage levels are available (i.e. 15 VDC, 36 VDC, etc) Contact the factory for details at: [email protected] Connections Input/Output Connector (CN1): • Terminal Block: Howder No. HB-95-7P 7 pins, M3.5 Screw, 9.5 mm Centers • JST Mating Part No: VHR5N or equivalent (two pins removed) VHR10N Crimp Terminals: SVH41T-P1.1 Pin T Block 1 +VOUT 2 +VOUT 3 -VOUT 4 -VOUT 5 Field Grnd 6 AC-Neutral 7 AC-Line Pin 1 2 3 4 5 6 7 8 9 10 JST +VOUT +VOUT +VOUT +VOUT +VOUT -VOUT -VOUT -VOUT -VOUT -VOUT 1 3 5 Field Grnd AC-Neutral AC-Line Logic Signal Connector (CN2): • JST Mating Part No: XHP-4 or equivalent • Mating Pins: JST SXH-002T-PO.6 For AWG 30 to 26 Pin Function 1 2 3 4 Remote On/Off Fan Fail Common Power Good Fan Driver Connector (CN3): • JSTMating Part No: JST XHP-2 or equivalent • Mating Pins: JST SXH-002T-PO.6 Pin Function 1 2 Plus Minus MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) FAX: (781) 344-8481 • E-Mail: [email protected]