Coaxial High Pass Filter 50Ω BHP-400+ 395 to 3200 MHz Features Maximum Ratings Operating Temperature -55°C to 100°C Storage Temperature -55°C to 100°C RF Power Input 0.5W max. • rugged shielded case • other standard and custom BHP models available with wide selection of fco CASE STYLE: FF55 Model Price Qty. BHP-400+ $36.95 ea. (1-9) Connectors BNC + RoHS compliant in accordance with EU Directive (2002/95/EC) Applications • lab use • transmitters/receivers • radio communications The +Suffix has been added in order to identify RoHS Compliance. See our web site for RoHS Compliance methodologies and qualifications. High Pass Filter Electrical Specifications STOPBAND (MHz) fco (MHz) Nom. PASSBAND (MHz) (loss > 40 dB) (loss > 20 dB) (loss 3 dB) (loss <1 dB) Stopband Typ. Passband Typ. DC-210 210-290 360 395-3200 17 1.7 typical frequency response Outline Drawing electrical schematic RF IN Attenuation, dB 40 Outline Dimensions ( inch mm ) 3 1 DC Typical Performance Data x σ 73.49 92.04 76.80 64.86 55.25 41.38 41.06 40.72 40.39 40.06 39.73 39.40 39.07 38.09 29.94 21.83 21.50 21.18 3.31 0.95 0.53 0.31 0.32 0.26 0.22 0.20 0.19 0.27 0.30 0.34 3.76 7.79 1.38 0.57 0.43 0.57 0.57 0.57 0.58 0.58 0.58 0.57 0.59 0.59 0.66 0.75 0.75 0.76 0.67 0.19 0.01 0.02 0.03 0.02 0.01 0.01 0.01 0.02 0.03 0.01 Return Loss (dB) Frequency (MHz) Group Delay (nsec) 0.05 0.05 0.11 0.09 0.10 0.17 0.17 0.18 0.17 0.18 0.18 0.18 0.18 0.18 0.22 0.33 0.33 0.34 4.07 11.83 21.31 23.56 17.14 19.37 24.00 28.18 29.90 18.44 17.29 21.10 10.00 100.00 150.00 175.00 200.00 240.00 241.00 242.00 243.00 244.00 245.00 246.00 247.00 250.00 275.00 300.00 301.00 302.00 360.00 380.00 400.00 500.00 600.00 700.00 800.00 900.00 1000.00 2000.00 3000.00 4000.00 17.71 57.88 0.94 0.34 1.22 1.56 1.56 1.57 1.57 1.58 1.61 1.60 1.60 1.61 1.96 2.53 2.56 2.59 6.64 6.00 4.41 2.06 1.35 1.02 0.83 0.71 0.61 0.35 0.31 0.30 RETURN LOSS at RF level of 0 dBm 1 GROUP DELAY (nsec) 10 25 20 15 10 5 0 1000 2000 FREQUENCY (MHz) 3000 4000 GROUP DELAY 10.0 1.0 0.1 0 0 at RF level of 0 dBm 100.0 30 RETURN LOSS (dB) INSERTION LOSS (dB) 35 .75 1 1.1 .5 Frequency/fco Insertion Loss (dB) _ 10.00 100.00 150.00 175.00 200.00 240.00 241.00 242.00 243.00 244.00 245.00 246.00 247.00 250.00 275.00 300.00 301.00 302.00 360.00 380.00 400.00 500.00 600.00 700.00 800.00 900.00 1000.00 2000.00 3000.00 4000.00 INSERTION LOSS at RF level of 0 dBm RF OUT 20 Frequency (MHz) 100 VSWR (:1) 0 1000 2000 3000 0 4000 1000 2000 3000 4000 FREQUENCY (MHz) FREQUENCY (MHz) Mini-Circuits ® EW ALL N minicircuits.com ISO 9001 ISO 14001 CERTIFIED P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661 For detailed performance specs & shopping online see Mini-Circuits web site The Design Engineers Search Engine Provides ACTUAL Data Instantly From MINI-CIRCUITS At: www.minicircuits.com RF/IF MICROWAVE COMPONENTS REV. C M113397 BHP-400+ 080603