XP Power ISB0112S12 Dc-dc converter Datasheet

ISB01 Series
DC-DC Converter
1 Watt
xxx Series
• Regulated Single & Dual Output
• 2:1 Input Range
• Compact SMD Package
• 1500 VDC Isolation
• Operating Temperature -40 °C to +95 °C
• Remote On/Off
• Tape & Reel Package Available
• Optional Water Washable Versions
• 3 Year Warranty
Dimensions:
ISB01:
0.74 x 0.68 x 0.34” (18.9 x 17.2 x 8.7 mm)
Models & Ratings
Input voltage
Output voltage
Output current
Input current(1,2)
No load
Full load
Maximum
Reflected ripple
capacitive load(3)
current
Efficiency
Model number(4)
5V
200 mA
256 mA
1680 µF
78%
ISB0105S05
12 V
83 mA
252 mA
820 µF
79%
ISB0105S12
15 V
67 mA
248 mA
680 µF
±12 V
±42 mA
255 mA
±15 V
±33 mA
5V
200 mA
12 V
83 mA
15 V
67 mA
±12 V
4.5-9V
40 mA
80 mA
81%
ISB0105S15
±470 µF
79%
ISB0105D12
248 mA
±330 µF
80%
ISB0105D15
105 mA
1680 µF
79%
ISB0112S05
105 mA
820 µF
79%
ISB0112S12
102 mA
680 µF
±42 mA
104 mA
±15 V
±33 mA
5V
200 mA
12 V
83 mA
15 V
67 mA
±12 V
9-18V
82%
ISB0112S15
±470 µF
81%
ISB0112D12
103 mA
±330 µF
80%
ISB0112D15
53 mA
1680 µF
79%
ISB0124S05
51 mA
820 µF
82%
ISB0124S12
51 mA
680 µF
±42 mA
51 mA
±15 V
±33 mA
5V
200 mA
12 V
83 mA
15 V
67 mA
±12 V
±15 V
18-36V
36-75V
20 mA
10 mA
40mA
82%
ISB0124S15
±470 µF
82%
ISB0124D12
50 mA
±330 µF
82%
ISB0124D15
26 mA
1680 µF
79%
ISB0148S05
26 mA
820 µF
80%
ISB0148S12
26 mA
680 µF
±42 mA
26 mA
±33 mA
25 mA
7 mA
30mA
20mA
80%
ISB0148S15
±470 µF
81%
ISB0148D12
±330 µF
81%
ISB0148D15
Notes
1. Input currents measured at nominal input voltage.
2. Input current is typically 2.5 mA at nominal input voltage when output is
remotely turned off.
3. Maximum capacitive load is per output.
4. For optional water washable version, add suffix ‘-P’ e.g. ISB0112S12-P.
Mechanical Details
0.74 (18.9)
0.60 (15.24)
0.5 (12.7)
0.1 (2.54)
9
14
8
Top View
1
2
6
0.04 (1.0)
1
7
0.54
(13.7)
0.68
(17.2)
0.33
(8.45)
0.01
(0.25)
S
0.04
(1.1)
0.6 (15.0)
www.xppower.com
Seating
Plane
0.73
(18.6)
0.54
(13.7)
0.64
(16.15)
0~
4
0.1
(1.8)
0.15 S
0.10
(2.54)
0.06
(1.6)
0.10
(2.45)
ISB01 Series
DC-DC Converter
Input
Characteristic
Minimum
Typical
4.5
Input Voltage Range
Input Filter
Maximum
Units
9
9.0
18
18.0
36
36.0
75
VDC
12 V nominal
24 V nominal
48 V nominal
Internal Capacitor
Input Surge
15
5 V nominal
25
12 V nominal
50
VDC for 1 s
24 V models
48 V models
100
Remote On/Off
Notes & Conditions
5 V nominal
ON: Logic high (2.5 - 5.5 V) or open circuit
OFF: Logic low (<0.8 V) or short pin 1 to pin 2
Output
Maximum
Units
Notes & Conditions
30
VDC
See Models and Ratings table
Initial Set Accuracy
±1.0
%
Output Voltage Balance
±1.0
%
For dual output with balanced laods
A
No minimum load required
Characteristic
Minimum
Output Voltage
Typical
5
Minimum Load
Line Regulation
±0.2
%
Load Regulation
±1.0
%
Cross Regulation
±5.0
%
5
% deviation
75
mV pk-pk
Transient Response
3
Ripple & Noise
On dual output models when one load is varied between
25% and 100% and other is fixed at 100%
Short Circuit Protection
Recovery within 1% in less than 250 µs for a 25% load
change.
20 MHz bandwidth. Measured using 0.47 µF ceramic
capacitor.
Continuous, with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
0.02
%/ ˚C
Maximum
Units
General
Characteristic
Minimum
Efficiency
Isolation: Input to Output
Isolation Resistance
Typical
80
pF
kHz
At 500 VDC
50
5.8
W/in3
220
Power Density
Mean Time Between Failure
Weight
See Models and Ratings table
60 s/1 s
109
Switching Frequency
Notes & Conditions
VDC
1500/1800
Isolation Capacitance
Moisture Sensitivity Level
%
Ω
2.8
MHrs
0.01 (4.5)
lb (g)
Level 2
At 1 V, 100 kHz
MIL-HDBK-217F, +25 °C GB
IPC/JEDEC J-STD-020D.1
Environmental
Characteristic
Maximum
Units
Notes & Conditions
Operating Temperature
Minimum
-40
Typical
+95
°C
See Derating Curve.
Storage Temperature
-55
+125
°C
Case Temperature
+95
°C
Humidity
95
%RH
Cooling
Case Flammability
Non-condensing
Natural convection
UL 94V-0 Rated
Non conductive black plastic
Lead-Free Reflow Solder Process
IPC/JEDEC J-STD-020D.1
www.xppower.com
2
ISB01 Series
DC-DC Converter
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
CB
IEC60950-1
ITE
UL
UL/cUL60950-1
ITE
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55022
Class A
Notes & Conditions
Mechanical Details
Connecting Pin Pattern
0.74 (18.9)
0.5 (12.7)
0.1
(1.8)
9
14
8
Top View
1
6
2
0.60 (15.24)
0.1 (2.54)
0.54
(13.7)
0.68
(17.2)
7
0.73
(18.6)
0.54
(13.7)
0.64
(16.15)
0.04 (1.0)
0.06
(1.6)
0.10
(2.54)
0.33
(8.45)
0.04
(1.1)
0.01
(0.25)
0.6 (15.0)
Seating
Plane
0~
4
S
0.15 S
0.10
(2.45)
Pin Connections
Pin
1
2
6
7
8
9
14
Single
-Vin
Remote On/Off
No Connection
No Connection
+Vout
-Vout
+Vin
Dual
-Vin
Remote On/Off
Common
-Vout
+Vout
Common
+Vin
Application Notes
Derating Curve
Output Power (%)
100
0
-40
75
95
Ambient Temperature (°C)
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.01 lbs (4.5 g) approx.
3
3. Tolerance: X.XX±0.01 (X.X±0.25)
X.XXX±0.005 (X.XX±0.13)
4. Pin Tolerance: ±0.002 (±0.05)
www.xppower.com
22 Dec 15