Astrodyne FKC05-48D15 Isolated and regulated 5 watt modular dc/dc converter Datasheet

FKC05
I s o l a t e d a n d R e gulated 5 WATT Modular DC/DC Converters
series
Wide 2 : 1 Input Range
High Efficiency
Regulated Outputs
500V Isolation
5 Sided EMI Shielding
Unit measures 0.8”W x 1.25”L x 0.4”H
Model Number
SINGLE OUTPUT
FKC05-12S05
FKC05-24S05
FKC0-48S05
FKC05-12S12
FKC05-24S12
FKC05-48S12
FKC05-12S15
FKC05-24S15
FKC05-48S15
DUAL OUTPUT
FKC05-12D05
FKC05-24D05
FKC05-48D05
FKC05-12D12
FKC05-24D12
FKC05-48D12
FKC05-12D15
FKC05-24D15
FKC05-48D15
DIP Package
Output Voltage
Output mAmps
Input Range
5 VDC
1
1
1
470
470
470
400
400
400
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
+/-500
+/-500
+/-500
+/-230
+/-230
+/-230
+/-190
+/-190
+/-190
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
12 VDC
15 VDC
+/-5 VDC
+/-12 VDC
+/-15 VDC
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
FKC05
I s o l a t e d a n d R e gulated 5 WATT Modular DC/DC Converters
ENVIRONMENTAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input Voltage Ranges:
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
9-18 VDC
18-36 VDC
36-75 VDC
Oper. Temperature
Storage Temperature
Maximum Case Temp
MTBF
-25 to +71 DegC(FL)
-55 to +105 DegC *
100 DegC *
3.165 Million Hrs
MIL-HDBK-217F TA=25C (FL)
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation (singles/duals)
Line Regulation
Temperature Coefficient
Ripple/Noise(Single/Dual)
Voltage Accuracy
Voltage Balance, Dual Outputs
Short Circuit Protection
series
See Selection Chart
+/- 0.2% / +/- 1% (25%-FL)
+/- 0.2% (singles/duals)
+/-0.02%/DegC
50mV Pk-Pk, typ
+/- 2%, typ
+/- 2%, typ
Continuous
PHYSICAL SPECIFICATIONS
Case Material MKC03
Construction
Weight
Nickel-Coated Copper
with Non-Conductive Base
Fully Encapsulated
0.6 oz, (14g)
GENERAL SPECIFICATIONS
Input-Out Isolation
Isolation Resistance
In/Out Capacitance
Efficiency
Switching Frequency
500VDC
10000 M Ohms
300 pF
FKC05-XXS(D)05
FKC05-XXS15,D12,D15
FKC05-XXS12
300Khz
78%, typ
81%, typ
82%, typ
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
FKC05
I s o l a t e d a n d R e gulated 5 WATT Modular DC/DC Converters
series
MECHANICAL DIMENSIONS
Pin size is 0.02(0.5) Dia or
0.01 x 0.02 (0.25 x 0.50)
Rectangular Pin
2
3
1.25 (31.8)
BOTTOM
VIEW
16
15
14
0.20 (5.1)
23
22
0.70 (17.8)
0.18(4.6)
9
10
11
0.60(15.2)
0.15
(3.8)
0.40
(10.2)
Pin #
Single Outputs
Dual Outputs
2
3
9
10
11
14
15
16
22
23
- Input
- Input
NC
NC
NC
+ Output
NC
- Output
+ Input
+ Input
- Input
- Input
Common
NC
- Output
+ Output
NC
Common
+ Input
+ Input
0.80(20.3)
OUTPUT POWER (%)
OUTPUT DERATING CURVE
100
75
50
25
Nature convection
0
-40 -25 -10 0
50 60 70 80 90 100
AMBIENT TEMPERATURE (ºC)
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
Similar pages