Littelfuse AHS120 Overcurrent protection device Datasheet

PolySwitch®
PTC Devices
PRODUCT: AHS120
DOCUMENT: SCD28207
REV LETTER: B
REV DATE: JULY 26, 2016
PAGE NO.: 1 OF 2
Overcurrent Protection Device
Specification Status: Released
Maximum Electrical Rating
C
Operating Voltage / Interrupt Current
16VDC / 50A
Marking:
B
G
H
D
A
E
F
Notes:
1. All metal surfaces are tin plated.
2. Drawing not to scale.
TABLE I. DIMENSIONS:
A
MIN
MAX
mm: 6.73
7.98
in*: (0.265) (0.314)
B
MIN
---
C
D
E
F
G
H
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
3.00
4.8
5.44
0.56
0.71
0.56
0.71
2.16
2.41
0.66
1.37
0.43
(0.118) (0.19) (0.214) (0.022) (0.028) (0.022) (0.028) (0.085) (0.095) (0.026) (0.054) (0.017)
TABLE II. PERFORMANCE RATINGS:
CURRENT RATINGS**
AMPS
AT 0°C
HOLD TRIP
1.36
3.29
AMPS
AT 20°C
HOLD TRIP
1.20
2.30
TIME TO
TRIP**
AMPS
SECONDS AT
AT 60°C
20°C, 8.0A
HOLD TRIP
MAX
0.83
1.60
2.0
RESISTANCE
VALUES
OHMS
AT 20°C
MIN
MAX*
0.150
0.340
TRIPPED-STATE
POWER
DISSIPATION**
WATTS AT
20°C
MAX
2.2
* Maximum resistance is measured 1 hour after reflow.
** Values specified were determined using PCB’s with 0.100”X2.0 ounce copper traces.
Reference Documents:
Precedence:
Effectivity:
CAUTION:
PS300, PS400
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.
Materials Information
ROHS Compliant
ELV Compliant
Pb-Free
Halogen Free*
HF
* Halogen Free refers to: Br≤900ppm, Cl≤900ppm, Br+Cl≤1500ppm.
© 2016 Littelfuse,Inc
Specifications are subject to change without notice.
Revised July 26, 2016
Littelfuse.com
PolySwitch®
PTC Devices
Overcurrent Protection Device
PRODUCT: AHS120
DOCUMENT: SCD28207
REV LETTER: B
REV DATE: JULY 26, 2016
PAGE NO.: 2 OF 2
Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their
own applications. Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, lifesaving,
life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired
operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation.
Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall
not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse
documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse.
© 2016 Littelfuse,Inc
Specifications are subject to change without notice.
Revised July 26, 2016
Littelfuse.com