Astrodyne DU1P0-24D12 Isolated and unregulated 1 watt modular dc/dc converter Datasheet

du1p0
I s o l a t e d a n d U n r egulated 1 WATT Modular DC/DC Converters
series
Low Cost
1 Watt in SIP Package
Unregulated Outputs
Input/Output Isolation up to 3KVDC
UL 94-V0 Non-Conductive Case
Internal Input & Output Filters
Unit measures 0.24”W x 0.77”L x 0.4”H
Model Number Output Voltage Output Amps
Input Range
Efficiency
Max I.P. Current
Max Load Capacitance
SINGLE OUTPUT
DU1P0-05S05(N) 5 VDC
DU1P0-12S05(N)
DU1P0-15S05(N)
DU1P0-24S05(N)
DU1P0-05S12(N) 12 VDC
DU1P0-12S12(N)
DU1P0-15S12(N)
DU1P0-24S12(N)
DU1P0-05S15(N) 15 VDC
DU1P0-12S15(N)
DU1P0-15S15(N)
DU1P0-24S15(N)
200
200
200
200
83
83
83
83
67
67
67
67
4.5-5.5 VDC
10.8-13.2 VDC
13.5-16.5 VDC
21.6-26.4 VDC
4.5-5.5 VDC
10.8-13.2 VDC
13.5-16.5 VDC
21.6-26.4 VDC
4.5-5.5 VDC
10.8-13.2 VDC
13.5-16.5 VDC
21.6-26.4 VDC
77%
77%
73%
72%
82%
82%
79%
78%
81%
79%
80%
78%
274mA
114mA
97mA
61mA
255mA
106mA
89mA
56mA
261mA
112mA
88mA
57mA
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
6.2uF
DUAL OUTPUT
DU1P0-05D05(N) +/-5 VDC
DU1P0-12D05(N)
DU1P0-15D05(N)
DU1P0-24D05(N)
DU1P0-05D12(N) +/-12 VDC
DU1P0-12D12(N)
DU1P0-15D12(N)
DU1P0-24D12(N)
DU1P0-05D15(N) +/-15 VDC
DU1P0-12D15(N)
DU1P0-15D15(N)
DU1P0-24D15(N)
+/-100
+/-100
+/-100
+/-100
+/-42
+/-42
+/-42
+/-42
+/-33
+/-33
+/-33
+/-33
4.5-5.5 VDC
10.8-13.2 VDC
13.5-16.5 VDC
21.6-26.4 VDC
4.5-5.5 VDC
10.8-13.2 VDC
13.5-16.5 VDC
21.6-26.4 VDC
4.5-5.5 VDC
10.8-13.2 VDC
13.5-16.5 VDC
21.6-26.4 VDC
78%
77%
75%
75%
82%
81%
80%
78%
81%
82%
80%
79%
270mA
114mA
94mA
59mA
258mA
109mA
88mA
57mA
257mA
106mA
87mA
55mA
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
3.0uF
Note - (N) Denotes that there is an optional 3000VDC Input to Output Isolation version available for the DU1P0 family of products. To order a DU1P0 product with the
optional 3000VDC Isolation, simply add an “N” to the end of the standard Part Number. For example DU1P0-05S05N.
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
du1p0
I s o l a t e d a n d U n r egulated 1 WATT Modular DC/DC Converters
INPUT SPECIFICATIONS
Input Voltage Ranges:
Input Current
Input Filter
ENVIRONMENTAL SPECIFICATIONS
5 VDC Nominal
4.5-5.5 VDC
12 VDC Nominal
10.8-13.2 VDC
15 VDC Nominal
13.5-16.5 VDC
24 VDC Nominal
21.6-26.4 VDC
(Nom Vin, Full Load)
See Selection Chart
Capacitor
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation (Note 1)
20% - FL
Line Regulation (HL-LL)
Temperature Coefficient
Ripple/Noise(Single/Dual)
Voltage Accuracy
Short Circuit Protection
Minimum Load (Note 1)
Max. Load Capacitance
series
Oper. Temperature
Storage Temperature
Relative Humidity
MTBF (Note 2)
Thermal Shock
Vibration
-25 to +85°C(See Derate Curve)
-55 to +105°C *
5% to 95% RH *
1.471 MHrs
MIL-STD-810D
10-55Hz, 10G, 30 Minutes
along X, Y, and Z
PHYSICAL SPECIFICATIONS
See Selection Chart
+/- 10% on 5V output
+/- 8% on all others
+/- 1.3%/1% of Vin
+/-0.1%/°C max.
100mV Pk-Pk, typ
+/-5%, max
1 Second max
10% of FL
Min Vin & Resitive Load
See Selection Chart
Dimensions
Case Material
Construction
Weight
0.77 x 0.24 x 0.40”
UL 94-V0 Non-Conductive
Black Plastic
Fully Encapsulated (UL94-V0)
2g (0.071oz)
NOTES
1) A Minimum 10% Load is required to maintain regulation
2) BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at
40°C. (Ground fixed and controlled environment)
GENERAL SPECIFICATIONS
Input-Out Isolation
Efficiency (Nom I/P & FL)
Switching Frequency
Isolation Resistance
Isolation Capacitance
Safety
1000VDC; (3000VDC suffix-N)
See Selection Chart
60Khz
10000 M Ohms
30pF, max.
UL, TUV, CB, CE
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
du1p0
I s o l a t e d a n d U n r egulated 1 WATT Modular DC/DC Converters
series
MECHANICAL DIMENSIONS
STANDARD MODELS
0.77(19.6)
0.016(0.4)
FRONT VIEW
0.40(10.2)
0.01x 0.02
( 0.25 x 0.5) Rectangular Pin
0.10(2.54)
0.14(3.6)
0.085(2.16)
0.24(6.1)
0.20(5.08)
1
BOTTOM VIEW
2
4 5 6 7
Single OutputsDual Outputs
1
2
4
5
6
7
+ Input
- Input
- Output
NC
+ Output
No Pin
+ Input
- Input
- Output
Common
+ Output
No Pin
0.053(1.35)
All dimensions in inches(mm)
Tolerance : x.xx±0.02(x.x±0.5)
x.xxx±0.01(x.xx±0.25)
Pin pitch tolerance ±0.014(0.35)
OUTPUT DERATING CURVE
OUTPUT POWER (%)
Pin #
“N” MODELS
Pin #
Single OutputsDual Outputs
1
2
4
5
6
7
+ Input
- Input
No Pin
- Output
NC
+ Output
+ Input
- Input
No Pin
- Output
Common
+ Output
100
75
50
Nature convection
25
0
-40 -25 -10 0
50 60 70 80 90 100
AMBIENT TEMPERATURE (ºC)
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181