Integral IN24LC08BD 4k/8k 2.5v cmos serial eeprom Datasheet

TECHNICAL DATA
IN24LC04B/08B
4K/8K 2.5V CMOS Serial EEPROMs
DESCRIPTION
IN24LC04B/08B is a 4K-or 8K-bit Electrically Erasable PROM. The device is organized as two or four blocks of 256 x
8 bit memory with a two wire serial interface. Low voltage design permits operation down to 2.5 volts with standby and
active currents of only 5µA and 1mA respectively. The IN24LC04B/08B also has a page-write capability for up to 16
bytes of data. The IN24LC04B/08B is available in the standard 8-pin DIP.
FEATURES
• Single supply with operation down to 2.5V
• Low power CMOS technology
- 1 mA active current typical
- 10 µA standby current typical at 5.5V
- 5 µA standby current typical at 3.0V
• Organized as two or four blocks of 256 bytes (2x256x8) and
PACKAGE
TA = -40 ... +85 °C
(4x256x8)
• Two wire serial interface bus, I2C compatible
• Schmitt trigger, filtered inputs for noise suppression
PINNING
• Output slope control to eliminate ground bounce
Name
Function
• 100 kHz (2.5V) and 400 kHz (5V) compatibility
Vss
Ground
• Self-timed write cycle (including auto-erase)
SDA
Serial Address/Data I/O
SCL
Serial Clock
WP
Write Protect Input
VCC
+2.5V to 5.5V Power Supply
AO, A1, A2
No Internal Connection
• Page-write buffer for up to 16 bytes
• 2 ms typical write cycle time for page-write
• Hardware write protect for entire memory
• Can be operated as a serial ROM
• Factory programming (QTP) available
• ESD protection > 4,000V
• 1,000,000 ERASE/WRITE cycles guaranteed*
Pin Connection
• Data retention > 200 years
• 8-pin DIP
A0
1
8
Vcc
A1
2
7
WP
A2
3
6
SCL
Vss
4
5
SDA
o
• Temperature range -40 to +85 C
1
IN24LC04B/08B
Figure 1. Representative Block Diagram
ELECTRICAL CHARACTERISTICS
Maximum Ratings*
Parameter
Value
VCC
All inputs and outputs w.r.t.Vss
Storage temperature
Ambient temp. with power applied
Soldering temperature of leads (10 seconds)
ESD protection on all pins
7.0 V
-0.3V to Vcc + 1.0V
-65oC to +150oC
-40 to +85oC
+300oC
> 4 kV
DC CHARACTERISTICS
Vcc = +2.5V to +5.5V Commercial: Tamb = -40to +85
Parameter
Symbol
Min
WP, SCL and SDA pins:
0.7VCC
High level input voltage
VlH
VIL
Low level input voltage
VHYS
0.05VCC
Hysteresis of Schmitt trigger inputs
VOL
Low level output voltage
Input leakage current
ILI
-10
Output leakage current
ILO
-10
Pin capacitance (all inputs/outputs)
CIN
COUT
Operating current
ICC WRITE
ICCREAD
Standby current
ICCS
-
Max
Units
0.3VCC
0.40
10
10
V
V
V
V
µA
µA
pF
10
3
1
30
100
mA
mA
µA
µA
Mode
Note 1
IOL = 3.0mA, VCC = 2.5V
VlN=0.1V to VCC
VOUT=0.1V to VCC
VCC = 5.0V (Note 1)
Tamb =25oC, Fclk =1MHz
VCC = 5.5V SCL = 400kHz
SDA=SCL=VCC=3.0V,
SDA=SCL=VCC=5.5V
2
IN24LC04B/08B
Figure 2. Bus timing Start/Stop
AC CHARACTERISTICS
Parameter
Clock frequency
Clock high time
Clock low time
SDA and SCL rise time
SDA and SCL fall time
START condition hold time
Symbol
STANDARD
MODE
Vcc = 4.5 - 5.5V
FAST MODE
Units Remarks
FCLK
THIGH
TLOW
TR
TF
Min
4000
4700
-
Max
100
1000
300
Min
600
1300
-
Max
400
300
300
THD:STA
4000
-
600
-
ns
TSU:STA
4700
-
600
-
ns
THD:DAT
TSU:DAT
TSU:STO
TAA
0
250
4000
-
3500
0
100
600
-
900
ns
ns
ns
ns
TBUF
4700
-
1300
-
ns
TOF
-
250
20+0.1CB
250
ns
TSP
-
50
-
50
ns
TWR
-
10
-
10
ms
kHz
ns
ns
ns Note 2
ns Note 2
START condition setup time
Data input hold time
Data input setup time
STOP condition setup time
Output valid from clock
Bus free time
Output fall time from VIH min
to VIL max
Input filter spike suppres-sion
(SDA & SCL pins)
Write cycle time
After this period the
first clock pulse is
generated
Only relevant for
repeated START
condition
Note 1
Time the bus must be
free before a new
transmission can start
Note2,
CB≤100pF
Note 3
Byte or Page
mode
Note 1: As a transmitter, the device must provide an internal minimum delay time to bridge the undefined
region (minimum 300 ns) of the falling edge of SCL to avoid unintended generation of START or
STOP conditions.
Note 2: Not 100% tested. CB = total capacitance of one bus line in pF.
Note 3: The combined TSP and VHYS specifications are due to new Schmitt trigger inputs which provide
improved noise and spike suppression. This eliminates the need for a Ti specification for standard
operation.
3
IN24LC04B/08B
Figure 3. Bus timing Data
FUNCTIONAL DESCRIPTION
The IN24LC04B/08B supports a bidirectional two wire bus and data transmission protocol. A
device that sends data onto the bus is defined as transmitter, and a device receiving data as receiver.
The bus has to be controlled by a master device which generates the serial clock (SCL), controls the
bus access, and generates the START and STOP conditions, while the IN24LC04B/08B works as
slave. Both, master and slave can operate as transmitter or receiver but the master device
determines which mode is activated.
BUS CHARACTERISTICS
The following bus protocol has been defined:
Data transfer may be initiated only when the bus is not busy.
During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in
the data line while the clock line is HIGH will be interpreted as a START or STOP condition.
Accordingly, the following bus conditions have been defined (see Figure 4).
Bus not Busy (A)
Both data and clock lines remain HIGH.
Start Data Transfer (B)
A HIGH to LOW transition of the SDA line while the clock (SCL) is HIGH determines a START
condition. All commands must be preceded by a START condition.
Stop Data Transfer (C)
A LOW to HIGH transition of the SDA line while the clock (SCL) is HIGH determines a STOP
condition. All operations must be ended with a STOP condition.
Data Valid (D)
The state of the data line represents valid data when, after a START condition, the data line is stable
for the duration of the HIGH period of the clock signal.
The data on the line must be changed during the LOW period of the clock signal. There is one clock
pulse per bit of data.
Each data transfer is initiated with a START condition and terminated with a STOP condition. The
number of the data bytes transferred between the START and STOP conditions is determined by the
master device and is theoretically unlimited, although only the last sixteen will be stored when
doing a write operation. When an overwrite does occur it will replace data in a first in first out
fashion.
4
IN24LC04B/08B
Acknowledge
Each receiving device, when addressed, is obliged to generate an acknowledge after the reception of
each byte. The master device must generate an extra clock pulse which is associated with this
acknowledge bit.
Note: The IN24LC04B/08B does not generate any acknowledge bits if an internal programming cycle is in
progress
The device that acknowledges, has to pull down the SDA line during the acknowledge clock pulse
in such a way that the SDA line is stable LOW during the HIGH period of the acknowledge related
clock pulse. Of course, setup and hold times must be taken into account. A master must signal an
end of data to the slave by not generating an acknowledge bit on the last byte that has been clocked
out of the slave. In this case, the slave must leave the data line HIGH to enable the master to
generate the STOP condition.
Figure 4. Data Transfer Sequence on the serial bus
BUS CHARACTERISTICS
Device Addressing and Operation
A control byte is the first byte received following the start condition from the master device. The
control byte consists of a four bit control code, for the IN24LC04B/08B this is set as 1010 binary
for read and write operations. The next three bits of the control byte are the block select bits (B2,
B1, BO). B2 is a don't care for both the IN24LC04B and IN24LC08B; B1 is a don't care for the
IN24LC04B. They are used by the master device to select which of the two or four 256 word blocks
of memory are to be accessed. These bits are in effect the most significant bits of the word address.
The last bit of the control byte defines the operation to be performed. When set to one a read
operation is selected, when set to zero a write operation is selected. Following the start condition,
the IN24LC04B/08B monitors the SDA bus checking the device type identifier being transmitted,
upon a 1010 code the slave device outputs an acknowledge signal on the SDA line. Depending on
the state of the R/W bit, the IN24LC04B/ 08B will select a read or write operation.
Operation
Read
Write
Control Code
1010
1010
Block Select
Block Address
Block Address
R/W
1
0
5
IN24LC04B/08B
Figure 5. Control Byte Allocation
WRITE OPERATION
Byte Write
Following the start condition from the master, the device code (4 bits), the block address (3 bits),
and the R/W bit which is a logic low is placed onto the bus by the master transmitter. This indicates
to the addressed slave receiver that a byte with a word address will follow after it has generated an
acknowledge bit during the ninth clock cycle. Therefore the next byte transmitted by the master is
the word address and will be written into the address pointer of the IN24LC04B/08B. After
receiving another acknowledge signal from the IN24LC04B/08B the master device will transmit the
data word to be written into the addressed memory location. The IN24LC04B/08B acknowledges
again and the master generates a stop condition. This initiates the internal write cycle, and during
this time the IN24LC04B/08B will not generate acknowledge signals (see Figure 6).
Page Write
The write control byte, word address and the first data byte are transmitted to the IN24LC04B/08B
in the same way as in a byte write. But instead of generating a stop condition the master transmits
up to sixteen data bytes to the IN24LC04B/08B which are temporarily stored in the on-chip page
buffer and will be written into the memory after the master has transmitted a stop condition. After
the receipt of each word, the four lower order address pointer bits are internally incremented by one.
The higher order seven bits of the word address remains constant. If the master should transmit
more than sixteen words prior to generating the stop condition, the address counter will roll over
and the previously received data will be overwritten. As with the byte write operation, once the stop
condition is received an internal write cycle will begin (see Figure 8).
Figure 6. Byte Write
6
IN24LC04B/08B
ACKNOWLEDGE POLLING
Since the device will not acknowledge during a write cycle, this can be used to determine when the
cycle is complete (this feature can be used to maximize bus throughput). Once
the stop condition for a write command has been
issued from the master, the device initiates the
Figure 7. Acknowledge Polling Flow
internally timed write cycle, ACK polling can be
initiated immediately. This involves the master
sending a start condition followed by the control
byte for a write command (R/W =0). If the
device is still busy with the write cycle, then no
ACK will be returned. If the cycle is complete,
then the device will return the ACK and the
master can then proceed with the next read or
write command. See Figure 7 for flow diagram.
WRITE PROTECTION
The IN24LC04B/08B can be used as a serial
ROM when the WP pin is connected to Vcc.
Programming will be inhibited and the entire
memory will be write-protected.
READ OPERATION
Read operations are initiated in the same way as
write operations with the exception that the R/W
bit of the slave address is set to one. There are
three basic types of read operations: current
address read, random read, and sequential read.
Current Address Read
The IN24LC04B/08B contains an address counter that maintains the address of the last word
accessed, internally incremented by one. Therefore, if the previous access (either a read or write
operation) was to address n, the next current address read operation would access data from address
n + 1. Upon receipt of the slave address with R/W bit set to one, the IN24LC04B/08B issues an
acknowledge and transmits the eight bit data word. The master will not acknowledge the transfer
but does generate a stop condition and the IN24LC04/08 discontinues transmission (see Figure 9).
Random Read
Random read operations allow the master to access any memory location in a random manner. To
perform this type of read operation, first the word address must be set. This is done by sending the
word address to the IN24LC04B/08B as part of a write operation. After the word address is sent,
the master generates a start condition following the acknowledge. This terminates the write
operation, but not before the internal address pointer is set. Then the master issues the control byte
again but with the R/W bit set to a one. The IN24LC04B/08B will then issue an acknowledge and
transmits the eight bit data word. The master will not acknowledge the transfer but does generate a
stop condition and the IN24LC04B/08B discontinues transmission (see Figure 10).
7
IN24LC04B/08B
Figure 8. Page Write
Figure 9. Current Address Read
Figure 10. Random Read
Sequential Read
Sequential reads are initiated in the same way as a random read except that after the
IN24LC04B/08B transmits the first data byte, the master issues an acknowledge as opposed to a
stop condition in a random read. This directs the IN24LC04B/08B to transmit the next sequentially
addressed 8 bit word (see Figure 11).
To provide sequential reads the IN24LC04B/08B contains an internal address pointer which is
incremented by one at the completion of each operation. This address pointer allows the entire
memory contents to be serially read during one operation.
Noise Protection
The IN24LC04B/08B employs a Vcc threshold detector circuit which disables the internal
erase/write logic if the Vcc is below 1,5 volts at nominal conditions.
The SCL and SDA inputs have Schmitt trigger and filter circuits which suppress noise spikes to
assure proper device operation even on a noisy bus.
8
IN24LC04B/08B
Figure 11. Sequential read
PIN DESCRIPTIONS
SPA Serial Address/Data Input/Output
This is a bidirectional pin used to transfer addresses and data into and data out of the device. It is an
open drain terminal, therefore the SDA bus requires a puliup resistor to Vcc (typical 10KΩ for 100
kHz, 1 KΩ for 400 kHz).
For normal data transfer SDA is allowed to change only during SCL low. Changes during SCL high
are reserved for indicating the START and STOP conditions.
SCL Serial Clock
This input is used to synchronize the data transfer from and to the device.
WP
This pin must be connected to either Vss or Vcc.
If tied to Vss, normal memory operation is enabled (read/write the entire memory).
If tied to Vcc, WRITE operations are inhibited. The entire memory will be write-protected. Read
operations are not affected.
This feature allows the user to use the IN24LC04B/08B as a serial ROM when WP is enabled (tied
to Vcc).
A0,A1,A2
These pins are not used by the IN24LC04B/08B. They may be left floating or tied to either Vss or
Vcc.
9
IN24LC04B/08B
N SUFFIX PLASTIC DIP
(MS – 001BA)
A
Dimension, mm
5
8
B
1
4
MIN
MAX
A
8.51
10.16
B
6.1
7.11
5.33
C
L
F
Symbol
C
D
0.36
0.56
F
1.14
1.78
-T- SEATING
PLANE
N
G
M
K
0.25 (0.010) M
J
H
D
T
NOTES:
1. Dimensions “A”, “B” do not include mold flash or protrusions.
Maximum mold flash or protrusions 0.25 mm (0.010) per side.
G
2.54
H
7.62
J
0°
10°
K
2.92
3.81
L
7.62
8.26
M
0.2
0.36
N
0.38
D SUFFIX SOIC
(MS - 012AA)
Dimension, mm
A
8
5
B
H
1
G
P
4
D
K
MIN
MAX
A
4.8
5
B
3.8
4
C
1.35
1.75
D
0.33
0.51
F
0.4
1.27
R x 45
C
-T-
Symbol
SEATING
PLANE
J
F
0.25 (0.010) M T C M
NOTES:
1. Dimensions A and B do not include mold flash or protrusion.
2. Maximum mold flash or protrusion 0.15 mm (0.006) per side
for A; for B ‑ 0.25 mm (0.010) per side.
M
G
1.27
H
5.72
J
0°
8°
K
0.1
0.25
M
0.19
0.25
P
5.8
6.2
R
0.25
0.5